Intrinsic safety 101 hazardous locations

Size: px
Start display at page:

Download "Intrinsic safety 101 hazardous locations"

Transcription

1 Intrinsic safety 101 hazardous locations Protection methods, containment, segregation, and prevention By Robert Schosker This article answers the question, Why worry about hazardous locations? The area classifications for the U.S. and the European (the International Electrotechnical Commission [IEC] standard) approaches are described and contrasted, including protection methods, containment, segregation, and prevention. What is intrinsic safety? Intrinsic safety (IS) has been around a long time. It is the concept of limiting ignition-capable energy to below that of the hazardous material a process may be working with. IS, as most people call it, was born out of the ashes of a horrible mining accident in the U.K. in The explosion was caused by a low-voltage signaling system that was used to advise the surface crew that coal cars were ready to be brought to the surface. The ensuing research revealed that the most important factor in determining the safety of an electrical circuit is the energy stored in the circuit. The concept of intrinsic safety was born. So why do we worry about hazardous locations? Many explosions are the result of limited knowledge by employees, which can be directly related to inadequate training, lack of documentation, and questionable safety measures. These disastrous results may have been prevented with proper training, new instrumentation, inspection, maintenance, or revised safety procedures. Of course, even if the plant takes these steps, an explosion could still happen; however, every effort to reduce residual risk is a benefit. Residual risk is the risk left over after all other forms or mechanical means of risk reductions have been taken. A hazardous area is an area containing (or likely to contain) an ignitable concentration of flammable gas, vapor, or dust, where an electrical spark of sufficient power will cause an explosion. However, an explosion can only occur when an oxidizer, the hazardous substance (gas, vapor, or dust), and energy (thermal or electrical) are present at the same time. These three groups comprise what is known as the hazardous location ignition triangle. If any one of these groups is removed, an explosion cannot happen. As we will discuss throughout this article, intrinsic safety is a method of protection that removes one of these groups from the ignition triangle. The article will first answer some basic questions about hazardous locations. We already know why we worry, but what are we worrying about? What is a hazardous location? What or who defines a hazardous location? What is the difference between zones and divisions? These are all very good questions, and ones that are often asked. We already know that a hazardous location is an area that contains or is likely to contain an ignitable concentration of flammable

2 gas, vapor, or dust. Once we have determined that a hazardous area exists, then we classify that area using either zones or divisions. Although the physical principles of explosion protection are the same worldwide and are not differentiated, the procedures determined by national legislation in the approximately 100-year history of explosion protection have resulted in various solutions. Each solution has a unique perspective on how to classify a hazardous area. Divisions, mainly a North American approved method of classifying an area, use four categories: class, division, group, and temperature. They are commonly seen like this: The categorization of these areas is carried out in North America in accordance with the National Electrical Code NFPA 70, article 500. Class I, II, or III represent the form of the hazardous material you must deal with. Division is a categorization by the probability that these materials will be present in a potentially hazardous quantity (Division 1 and Division 2). The division is commonly the perimeter or designated area of the hazardous material.

3 Furthermore, classes of hazardous areas are divided into subgroups depending on the type of flammable gas or vapor present. Finally, apparatus installed directly in a hazardous area must be classified for the maximum surface temperature that the device will produce under normal operation or in the event of a fault. The maximum surface temperature must be below the minimum ignition temperature of the gas present.

4 The graphical representation below illustrates the concept of division-based areas. In Europe, the zone method of area classification is used. The European zone practice is described in IEC/EN In accordance with this standard, any area where there is a probability that flammable gas or dispersed dust may exist must be classified into one of the following areas:

5 The European zones then require that the apparatus be subdivided into two groups, according to IEC/EN These two groups in general terms indicate whether the apparatus is located above or below ground. And as with divisions and gas groups, there are subgroups of Group I and II within the zones. Each is associated with a certain number of gases having an ignition energy in the value reported and is represented by the gas referenced in the table below. Included in this comparison are the Class I and II division-based classifications.

6 A temperature code is also required just like divisions; however, the zone method is simplified. With both divisions and zones, the maximum surface temperature must be below the minimum ignition temperature of the gas present. The graphical representation illustrates the concept of zone-based areas. The article has explained hazardous areas and how those areas are classified, but what methods of protection exist for your hazardous areas? As previously mentioned, to reduce the risk of explosion, you must eliminate one or more of the components of the ignition triangle. There are three basic methods of protection: explosion containment, segregation, and prevention.

7 Explosion containment: the only method that allows the explosion to occur, but confines it to a well-defined area, thus avoiding the propagation to the surrounding atmosphere. Flameproof and explosion-proof enclosures are based on this method. Segregation: a method that attempts to physically separate or isolate the electrical parts or hot surfaces from the explosive mixture. This method includes various techniques, such as pressurization and encapsulation. Prevention: a method that limits the energy, both electrical and thermal, to safe levels under both normal operation and fault conditions. Intrinsic safety is the most representative technique of this method. The protection methods, based on the containment and segregation concepts, are methods that contain the explosion in order to prevent the energy source electrical or thermal from coming in contact with the potentially explosive mixture. In both cases, the use of appropriate enclosures and specific wiring and installation systems is required. The intrinsic safety method prevents the ignition of the explosive atmosphere, while simplifying the installation and use of the required apparatus that is connected to the electrical circuits directly located in a hazardous location. The choice of a specific protection method depends on the degree of safety needed for the type of hazardous area. The idea is to determine the best protection method based on the lowest probable degree of the simultaneous presence of an adequate energy source and a dangerous concentration level of an air/gas mixture. Of course, other important factors to consider include the size of the apparatus to be protected, the flexibility of the system, the possibility of needing to perform maintenance, and the installation cost. Respective of these factors, intrinsic safety has many advantages. So what is intrinsic safety? Intrinsic safety is based on the principle of limiting energy to a level below that required to ignite the hazardous gas or dust. The energy limitation also pertains to thermal energy as well. Therefore, in normal operation or in the event of a fault, no sparks or thermal effects may occur that could lead to the ignition of a potentially explosive atmosphere. It is one thing to understand intrinsic safety as a concept, but it has to be applied correctly to work. As shown in the illustration, there are three components to an intrinsically safe circuit:

8 The field device intrinsically safe equipment located in the hazardous location Intrinsically safe barrier or associated apparatus located in nonhazardous location Interconnecting wire between the two apparatus The example here is simple, because the fault combinations are few, and the knowledge of the apparatus safety parameters and cable characteristics are sufficient to verify the safety of the system. A more complex system (combinations of barriers or using multiple cables) requires a more detailed analysis because there are many fault combinations to verify, and they are not always evident. As mentioned above, more complex analysis may be required with intrinsic safety, but with this in mind, intrinsic safety has several advantages over the other methods of protection. They include allowing trained personnel to connect and disconnect circuits under live operation. They are guaranteed to be safe during short circuits or lead breakage. Intrinsic safety is the only ignition protection class that allows connectors to be opened and intrinsically safe apparatus to be removed and replaced by an equivalent device in a hazardous area. Intrinsic safety is also the only method that allows general-purpose wiring methods to be used in the hazardous area. These simple advantages also generate cost savings through installation and maintenance, because this method allows live maintenance with no need for plant shutdown. Intrinsic safety is also more reliable due to the use of infallible and derated components as prescribed by the standards. Intrinsic safety was born from the ashes of a horrific accident to become the most widely accepted method of protection. Not only does it limit voltage and current, but it provides a 50 percent safety margin even during fault conditions; no other method of protection can claim that. In the end, it is the end users who must determine the area of classification, the required process equipment, and the method of protection they want to use. If they decide to use intrinsic safety, I think they will find that it provides the best mix of an affordable system and the safety required. ABOUT THE AUTHOR Robert Schosker is the product manager for intrinsic safety, HART, signal conditioners, and surge protection for Pepperl+Fuchs. Since joining Pepperl+Fuchs in 1995, he has been focused on technology and productrelated support, and is involved in a wide range of activities and roles including certifications, sales, and marketing. He has been the key lead in many IS and HART projects resulting in the development of new products for intrinsic safety and HART infrastructure. Schosker holds a BSEE from the University of Akron. Direct questions or comments to pa-info@us.pepperl-fuchs.com.

9 Source: ment/contentdisplay.cfm&contentid=94304

1.8 INDUSTRIAL PROCESS WEIGHING IN HAZARDOUS AREAS

1.8 INDUSTRIAL PROCESS WEIGHING IN HAZARDOUS AREAS 1.8 INDUSTRIAL PROCESS WEIGHING IN HAZARDOUS AREAS EXPLOSION PROTECTION In addition to the type approval and certification of industrial weighing systems concerned with accuracy, equipment that is also

More information

NZQA registered unit standard version 2 Page 1 of 7. Conduct a conformity assessment of explosion-protected apparatus

NZQA registered unit standard version 2 Page 1 of 7. Conduct a conformity assessment of explosion-protected apparatus Page 1 of 7 Title Conduct a conformity assessment of explosion-protected apparatus Level 6 Credits 9 Purpose This unit standard covers the assessment and certification of explosion-protected apparatus

More information

NZQA registered unit standard version 3 Page 1 of 7. Plan electrical installations for explosive atmospheres

NZQA registered unit standard version 3 Page 1 of 7. Plan electrical installations for explosive atmospheres Page 1 of 7 Title Plan electrical installations for explosive atmospheres Level 5 Credits 8 Purpose This unit standard is intended for use in the training and assessment of people who work with electrical

More information

Session #: Selection of Explosion Protected Equipment for Hazardous Locations

Session #: Selection of Explosion Protected Equipment for Hazardous Locations Abstract Session #: (Arial 16) Selection of Explosion Protected Equipment for Hazardous Locations Pieter Coetzee Explosion Prevention Consultant Registered person How can we mitigate the risks of explosions

More information

NZQA registered unit standard version 1 Page 1 of 8. Conduct detailed inspection of electrical installations for explosive atmospheres

NZQA registered unit standard version 1 Page 1 of 8. Conduct detailed inspection of electrical installations for explosive atmospheres Page 1 of 8 Title Conduct detailed inspection of electrical installations for explosive atmospheres Level 5 Credits 5 Purpose This unit standard is intended for use in the training and assessment of people

More information

NZQA registered unit standard version 3 Page 1 of 6

NZQA registered unit standard version 3 Page 1 of 6 Page 1 of 6 Title Report on the integrity of explosion-protected electrical apparatus in explosive atmospheres Level 3 Credits 3 Purpose This unit standard covers the explosion-protection aspects of plant

More information

Explosion Protection Technology Pty Ltd

Explosion Protection Technology Pty Ltd How to Apply Hazardous Area Australian Standards (Group II) 3-Day On-Site Workshop * 2018 This workshop provides a sound understanding of electrical compliance and your responsibilities in Group II hazardous

More information

Electrical Equipment and Installations in Hazardous Areas. Univerza v Ljubljani Fakulteta za elektrotehniko

Electrical Equipment and Installations in Hazardous Areas. Univerza v Ljubljani Fakulteta za elektrotehniko Univerza v Ljubljani Fakulteta za elektrotehniko Electrical Equipment and Installations in Hazardous Areas Student: Tiago da Silva Oliveira; Student Number: 70080035; Subject: Electrical Installations

More information

IE073: Intrinsic Safety, Galvanic Isolation and Zener Barriers Technology & Applications

IE073: Intrinsic Safety, Galvanic Isolation and Zener Barriers Technology & Applications IE073: Intrinsic Safety, Galvanic Isolation and Zener Barriers Technology & Applications IE073 Rev.001 CMCT COURSE OUTLINE Page 1 of 5 Training Description: The hazardous-area circuits 'float' i.e. is

More information

IECEx OPERATIONAL DOCUMENT

IECEx OPERATIONAL DOCUMENT IECEx OD 504 Edition 1.0 2009-09 IECEx OPERATIONAL DOCUMENT IEC System for Certification to Standards relating to Equipment for use in Explosive Atmospheres (IECEx System) IECEx Scheme for Certification

More information

Understanding safety life cycles

Understanding safety life cycles Understanding safety life cycles IEC/EN 61508 is the basis for the specification, design, and operation of safety instrumented systems (SIS) Fast Forward: IEC/EN 61508 standards need to be implemented

More information

Hazardous Location Coding System - NEC 500. Type of Protection. XP = Explosionproof. IS = Intrinsically Safe Apparatus

Hazardous Location Coding System - NEC 500. Type of Protection. XP = Explosionproof. IS = Intrinsically Safe Apparatus Hazardous Location Equipment - United States Equipment listed in this category for Hazardous (Classified) Locations is also suitable for installations in areas that are unclassified locations and, unless

More information

The Software. Hazardous distance

The Software. Hazardous distance The Software The software Atmosphere Risk Analysis Gas Plus ( AraGasPlus) is a support tool to carry out all the necessary actions that an employer must comply with the Directive 99/92/EC concerning minimum

More information

RTD temperature probes

RTD temperature probes RTD temperature probes Ex i for use in areas with an explosion hazard (Ex areas) Persons concerned: Experienced professional electricians as per EU Directive 1999/92/EC and trained personnel Operating

More information

User s Manual EJX/EJA-E Series NEPSI Certification [Option code: /NF2, /NS21, /NS24 and /NS25] IM 01C25A00-12E

User s Manual EJX/EJA-E Series NEPSI Certification [Option code: /NF2, /NS21, /NS24 and /NS25] IM 01C25A00-12E User s Manual EJX/EJA-E Series NEPSI Certification [Option code: /NF2, /NS21, /NS24 and /NS25] 12th Edition 1 1. Introduction Thank you for purchasing the DPharp electronic pressure transmitter. This manual

More information

Dangerous Substances & Explosive Atmospheres Regulation 2002 The Basics. Richard Cowen Dip SH, Dip RSA, CMIOSH, MIIRSM, FRSPH, GI Fire E

Dangerous Substances & Explosive Atmospheres Regulation 2002 The Basics. Richard Cowen Dip SH, Dip RSA, CMIOSH, MIIRSM, FRSPH, GI Fire E Dangerous Substances & Explosive Atmospheres Regulation 2002 The Basics Richard Cowen Dip SH, Dip RSA, CMIOSH, MIIRSM, FRSPH, GI Fire E DSEAR Regulations 2002 Sets minimum requirements for the protection

More information

Explosion Protection Technology Pty Ltd

Explosion Protection Technology Pty Ltd RRRHazardous Area Australian Standards Simplified 2-Day Workshop * Tuesday 24 - Wednesday 25 July 2018 This workshop provides an introduction to electrical compliance and your responsibilities in Group

More information

A Unified Marking System for Ex Equipment

A Unified Marking System for Ex Equipment CERTEX Appointed Ex Laboratory Reg No: 1999/027771/07 (Pty) Ltd Government Approved Inspection Authority T0104 PO Box 467 Tel: +27 (11) 316 4601 Olifantsfontein Fax: +27 (11) 316 5670 1665 E- mail: info@explolabs.co.za

More information

Hazardous Location Coding System - For Division. Class I / II / III, Division 1 / 2 Type of Protection. XP = Explosionproof

Hazardous Location Coding System - For Division. Class I / II / III, Division 1 / 2 Type of Protection. XP = Explosionproof Hazardous Location Equipment - Canada Equipment listed in this category for Hazardous Locations is also suitable for installations in areas that are non-hazardous locations and, unless referenced in the

More information

PART II RULES FOR THE CONSTRUCTION AND CLASSIFICATION OF VESSELS IDENTIFIED BY THEIR MISSIONS TITLE 104 CARRIAGE OF DANGEROUS GOODS

PART II RULES FOR THE CONSTRUCTION AND CLASSIFICATION OF VESSELS IDENTIFIED BY THEIR MISSIONS TITLE 104 CARRIAGE OF DANGEROUS GOODS PART II RULES FOR THE CONSTRUCTION AND CLASSIFICATION OF VESSELS IDENTIFIED BY THEIR MISSIONS TITLE 104 CARRIAGE OF DANGEROUS GOODS SECTION 7 ELECTRICITY CHAPTERS A APPROACH B DOCUMENTS, REGULATIONS AND

More information

TECHNOLOGY GUIDE NO. 12

TECHNOLOGY GUIDE NO. 12 SSPC: The Society for Protective Coatings TECHNOLOGY GUIDE NO. 12 Guide for Illumination of Industrial Painting Projects SSPC-Guide 12 1. Scope 1.1 This guide provides information on the quantity and quality

More information

ENGINEERING STANDARD FOR HAZARDOUS AREA SECOND EDITION JANUARY 2016

ENGINEERING STANDARD FOR HAZARDOUS AREA SECOND EDITION JANUARY 2016 IPS-E-EL-110(2) ENGINEERING STANDARD FOR HAZARDOUS AREA SECOND EDITION JANUARY 2016 This Standard is the property of Iranian Ministry of Petroleum. All rights are reserved to the owner. Neither whole nor

More information

TechNote FM APPROVAL: HAZARDOUS LOCATION EQUIPMENT CLASSIFICATION

TechNote FM APPROVAL: HAZARDOUS LOCATION EQUIPMENT CLASSIFICATION TechNote FM APPROVAL: HAZARDOUS LOCATION EQUIPMENT CLASSIFICATION Equipment listed in this guide for Hazardous (Classified) Locations is also suitable for installations in areas that are unclassified locations

More information

WHITEPAPER: ATEX IN PRACTICE (EXPLOSION PROTECTION)

WHITEPAPER: ATEX IN PRACTICE (EXPLOSION PROTECTION) WHITEPAPER: ATEX IN PRACTICE (EXPLOSION PROTECTION) www.ottevanger.com It is essential that both machine manufacturers and owners of process installations have the necessary knowledge about the Atex directives

More information

MANUAL DIRECT PURGE OPTION. UNION Instruments GmbH CWD2005 PLUS. General information, safety standards and regulations for direct purge option

MANUAL DIRECT PURGE OPTION. UNION Instruments GmbH CWD2005 PLUS. General information, safety standards and regulations for direct purge option MANUAL DIRECT PURGE OPTION UNION Instruments GmbH CWD2005 PLUS General information, safety standards and regulations for direct purge option Version: V1.00 Stand: 24.03.2010 Union Instruments GmbH Zeppelinstr.

More information

Hazardous (Classified) Locations

Hazardous (Classified) Locations Hazardous (Classified) Locations Presented by: John Chambers UL HazLoc operations Presented at: Safety & You in 2002 2002 Safety Conference Flexible Packaging Association (FPA) 1 AREA CLASSIFICATIONS Class

More information

Safe Work Practices / Procedures / Instruction CONFINED SPACE

Safe Work Practices / Procedures / Instruction CONFINED SPACE CONFINED SPACE Entry into and work in a confined space poses health and safety problems which may include: Presence or possible build up of a hazardous atmosphere Unexpected movement of equipment or materials

More information

ELECTRICAL (COMPREHENSIVE) SAFETY PROGRAM REGULATORY STANDARD: OSHA - 29 CFR CFR , ,

ELECTRICAL (COMPREHENSIVE) SAFETY PROGRAM REGULATORY STANDARD: OSHA - 29 CFR CFR , , ELECTRICAL (COMPREHENSIVE) SAFETY PROGRAM REGULATORY STANDARD: OSHA - 29 CFR 1910.331 335-29 CFR 1926.302, 1926.416, 1926.417 BASIS: The National Safety Council estimates that there are at least 300 deaths

More information

A study on the relation between safety analysis process and system engineering process of train control system

A study on the relation between safety analysis process and system engineering process of train control system A study on the relation between safety analysis process and system engineering process of train control system Abstract - In this paper, the relationship between system engineering lifecycle and safety

More information

Rockhampton Office Brisbane Office Tarong Site. Barron Gorge Hydro PS Kareeya Hydro PS Mica Creek PS

Rockhampton Office Brisbane Office Tarong Site. Barron Gorge Hydro PS Kareeya Hydro PS Mica Creek PS Business Procedure Hot Work Document Number OHS-PROC-128 This document applies to the following sites: All Sites Rockhampton Office Brisbane Office Tarong Site Barron Gorge Hydro PS Kareeya Hydro PS Mica

More information

II 2G EEx ia IIC T6. Ignition protection class

II 2G EEx ia IIC T6. Ignition protection class ATEX General information According to 94/9/EC, a device that is to be used in an environment at risk of explosion may only be brought into the market if it satisfies the standards specified in the norm.

More information

Supplementary Operator s Manual 42/24-14 EN Rev. 3

Supplementary Operator s Manual 42/24-14 EN Rev. 3 Advance Optima Continuous Gas Analyzers AO2000 Series with Uras26, Magnos206, Caldos25, Caldos27 Designed per Category 3G for Measurement of Flammable Gases ( Safety Concept ) and Non-flammable Gases Supplementary

More information

Hot Work Program. University of Wisconsin-Platteville Reviewed 4/2016

Hot Work Program. University of Wisconsin-Platteville Reviewed 4/2016 Hot Work Program University of Wisconsin-Platteville Reviewed 4/2016 The purpose of the Hot Work Program is to establish safety procedures for employees, contractors, and subcontractors engaging in any

More information

Wireless I/O, Connecting Remote Sensors in a Wide Range of Environments

Wireless I/O, Connecting Remote Sensors in a Wide Range of Environments Gas Well Deliquification Workshop Sheraton Hotel, February 19 22, 2012 Wireless I/O, Connecting Remote Sensors in a Wide Range of Environments Glenn Longley, Sr. Product Manager FreeWave Technologies Agenda

More information

CERTIFICATE OF COMPLIANCE

CERTIFICATE OF COMPLIANCE FM Approvals 1151 Boston Providence Turnpike P.O. Box 9102 Norwood, MA 02062 USA T: 781 762 4300 F: 781-762-9375 www.fmapprovals.com CERTIFICATE OF COMPLIANCE HAZARDOUS (CLASSIFIED) LOCATION ELECTRICAL

More information

Scope: This plan applies to all personnel, including contractors, who enter or work in confined spaces, or supervise such activities.

Scope: This plan applies to all personnel, including contractors, who enter or work in confined spaces, or supervise such activities. 11/13/1995 4 5/20/2013 1 of 10 Authority and Scope Regulation: 29 CFR 1910.146 Scope: This plan applies to all personnel, including contractors, who enter or work in confined spaces, or supervise such

More information

NZQA unit standard 7145 version 9 Page 1 of 5. Design and maintain effective ventilation systems for an underground coal mine

NZQA unit standard 7145 version 9 Page 1 of 5. Design and maintain effective ventilation systems for an underground coal mine Page 1 of 5 Title Design and maintain effective ventilation systems for an underground coal mine Level 5 Credits 20 Purpose People credited with this unit standard are able to, for an underground coal

More information

Describe Flammable Gas Measurement

Describe Flammable Gas Measurement Training Module Describe Flammable 100% 90% C 80% No Combustion 70% 60% 50% 40% 30% 20% UEL B Combustion No Combustion 10% 0% LEL A Human Development HDC Human Development All rights reserved. No part

More information

Hafner-Pneumatik presents: General information on ATEX 95 & Products for explosion hazardous environment from the Hafner range

Hafner-Pneumatik presents: General information on ATEX 95 & Products for explosion hazardous environment from the Hafner range Hafner-Pneumatik presents: Including Pneumatic Valves General information on ATEX 95 & Products for explosion hazardous environment from the Hafner range General information - 1 A product that is supposed

More information

Instruction Manual for Intrinsically Safe - Reed Switches

Instruction Manual for Intrinsically Safe - Reed Switches Instruction Manual for Intrinsically Safe - Reed Switches Option Code: -1S2-IS-LED or -2S2-IS-LED -1S2-IS or -2S2-IS ATEX RCM Industries, Inc. Direct Reading Differential Pressure Flowmeters 110 Mason

More information

Pressure switch KP-E. Data sheet

Pressure switch KP-E. Data sheet Data sheet Pressure switch KP-E KP-E pressure switches for use in refrigeration and air conditioning systems are equipped with SPDT gold plated contacts and stainless steel bellows. The high pressure switches

More information

AIDGC PRESENTATION MARCH 2006 HAZARDOUS AREAS STANDARDS & CLASSIFICATION

AIDGC PRESENTATION MARCH 2006 HAZARDOUS AREAS STANDARDS & CLASSIFICATION AIDGC PRESENTATION MARCH 2006 HAZARDOUS AREAS STANDARDS & CLASSIFICATION Jeff Strath Principal Engineer Paterson Flood Engineers Pty Ltd www.pfe.com.au INTRODUCTION This presentation provides an overview

More information

The Best Use of Lockout/Tagout and Control Reliable Circuits

The Best Use of Lockout/Tagout and Control Reliable Circuits Session No. 565 The Best Use of Lockout/Tagout and Control Reliable Circuits Introduction L. Tyson Ross, P.E., C.S.P. Principal LJB Inc. Dayton, Ohio Anyone involved in the design, installation, operation,

More information

LOCKOUT/TAGOUT PROGRAM

LOCKOUT/TAGOUT PROGRAM LOCKOUT/TAGOUT PROGRAM HOW CLIMATE ENGINEERS INC. COMPLIES WITH THELO/TO STANDARD It is the intent of Climate Engineers Inc. to comply with OSHA s Control of Hazardous Energy Standard (1910.147). The following

More information

NZQA unit standard version 3 Page 1 of 8. Manage the mine ventilation system at an extractive site

NZQA unit standard version 3 Page 1 of 8. Manage the mine ventilation system at an extractive site Page 1 of 8 Title Manage the mine ventilation system at an extractive site Level 7 Credits 30 Purpose This unit standard covers the development and management of the operation and maintenance of a mine

More information

FLAMMABLE & COMBUSTIBLE LIQUIDS PROGRAM

FLAMMABLE & COMBUSTIBLE LIQUIDS PROGRAM FLAMMABLE & COMBUSTIBLE LIQUIDS PROGRAM 1.0 PURPOSE This program applies to employees, visitors and contractors (persons) for the purpose of articulating safe work practices when working with and around

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 2419437 Master Contract: 203012 Issued to: ABB Automation Products GmbH 72 Schillerstrasse Minden, 32425 Germany Attention: Ralf Schaffer The products listed below

More information

Protocol for Confined Space Entry Requirements

Protocol for Confined Space Entry Requirements Occupational Health and Safety (OHS) Policy Document Number # QH-PTL-275-12-1:2012 Protocol for Confined Space Entry Custodian/Review O fficer: Director Safety and Wellbeing Version no: 1.0 Applicable

More information

Recognition, Evaluation, and Control of Hazards

Recognition, Evaluation, and Control of Hazards Recognition, Evaluation, and Control of Hazards Latest revised date: October 26, 2011 Page 1 of 8 1.0 Introduction Memorial University has established a system for the recognition, evaluation, and control

More information

THE PETROLEUM INDUSTRY Code of Practice

THE PETROLEUM INDUSTRY Code of Practice DZS 385 Part 2 : 2015 ICS 13.300; 75.200 SECOND EDITION Draft for Public comment ZAMBIAN STANDARD THE PETROLEUM INDUSTRY Code of Practice Part 2: Electrical installations in the distribution and marketing

More information

CLASSIFICATION OF LOCATIONS FOR ELECTRICAL INSTALLATIONS IN GAS UTILITY AREAS. Gerry Pickens

CLASSIFICATION OF LOCATIONS FOR ELECTRICAL INSTALLATIONS IN GAS UTILITY AREAS. Gerry Pickens CLASSIFICATION OF LOCATIONS FOR ELECTRICAL INSTALLATIONS IN GAS UTILITY AREAS Gerry Pickens Atmos Energy 810 Crescent Centre Drive Franklin, TN 37067 The National Electrical Code (NEC) defines hazardous

More information

BASIC NATIONAL ELECTRIC CODE APPLICABLE TO MEASUREMENT. Gerry Pickens. Atmos Energy 810 Crescent Centre Drive Franklin, TN 37067

BASIC NATIONAL ELECTRIC CODE APPLICABLE TO MEASUREMENT. Gerry Pickens. Atmos Energy 810 Crescent Centre Drive Franklin, TN 37067 BASIC NATIONAL ELECTRIC CODE APPLICABLE TO MEASUREMENT The National Electrical Code (NEC) defines hazardous locations as those areas "where fire or explosion hazards may exist due to flammable gases or

More information

Key Technology, Inc. Confined Space Entry Program. July, 2017

Key Technology, Inc. Confined Space Entry Program. July, 2017 Key Technology, Inc. Confined Space Entry Program July, 2017 Page 1 of 11 Key Technology, Inc. CONFINED SPACE ENTRY PROGRAM OVERVIEW Purpose: The purpose of this program is to ensure the protection of

More information

The Omron STI Hazardous Location

The Omron STI Hazardous Location Hazardous Location Rating Systems for Interlock Switches The Omron STI Hazardous Location Rated Safety Interlock Switches presented in this catalog are classified by the European standard as Ex, ExdIIc

More information

TABLE OF CONTENTS PART 2 - CONFINED SPACES

TABLE OF CONTENTS PART 2 - CONFINED SPACES May 11, 2006 TABLE OF CONTENTS PART 2 - CONFINED SPACES Page DEFINITIONS... 2-1 GENERAL... 2-2 RESPONSIBILITIES... 2-2 HAZARD ASSESSMENT AND WORK PROCEDURES... 2-3 IDENTIFICATION AND ENTRY PERMITS... 2-3

More information

INOGATE Technical Secretariat UK Experience European Standards Implementation Key Expert Phil Winnard Session 2 Georgia, October 2015

INOGATE Technical Secretariat UK Experience European Standards Implementation Key Expert Phil Winnard Session 2 Georgia, October 2015 INOGATE Technical Secretariat UK Experience European Standards Implementation Key Expert Phil Winnard Session 2 Georgia, October 2015 BUILDING PARTNERSHIPS FOR ENERGY SECURITY www.inogate.org EN 12186

More information

Inductive slot sensor

Inductive slot sensor 0102 Model Number Features 3.5 mm slot width Usable up to SIL 3 acc. to IEC 61508 Nonferrous targets Application Danger! In safety-related applications the sensor must be operated with a qualified fail

More information

Pioneers. Ex-ENGINEERING. Quality

Pioneers. Ex-ENGINEERING. Quality Pioneers The increasing demands of industry for dependable explosionproof lighting, motivated Baliga to pioneer the design and manufacture of a quality line way back in 1962, when the first Indian Standards

More information

Flammable Environments Guideline

Flammable Environments Guideline GUIDE Flammable Environments Guideline 2014-0004 The Canadian Association of Petroleum Producers (CAPP) represents companies, large and small, that explore for, develop and produce natural gas and crude

More information

Preventive Maintenance

Preventive Maintenance A Health and Safety Guideline for Your Workplace Why? Preventive maintenance is predetermined work performed to a schedule with the aim of preventing the wear and tear or sudden failure of equipment components.

More information

flammable dust II 1D or II 1/2D or II 1/3D Level measuring devices and silo equipment for the potentially explosive atmospheres

flammable dust II 1D or II 1/2D or II 1/3D Level measuring devices and silo equipment for the potentially explosive atmospheres provides: Level measuring devices and silo equipment for the potentially explosive atmospheres flammable dust with ATEX certification: II 1D or II 1/2D or II 1/3D Level measuring devices and silo equipment

More information

NZQA unit standard New US 1Non-coal of 7145 version 1 Page 1 of 5

NZQA unit standard New US 1Non-coal of 7145 version 1 Page 1 of 5 Page 1 of 5 Title Design and maintain effective ventilation systems for a non-coal underground operation Level 5 Credits 20 Purpose People credited with this unit standard are able to: explain the principles

More information

CABLE ENTRIES IN HAZARDOUS AREAS CORRECT SELECTION, INSTALLATION AND MAINTENANCE

CABLE ENTRIES IN HAZARDOUS AREAS CORRECT SELECTION, INSTALLATION AND MAINTENANCE CABLE ENTRIES IN HAZARDOUS AREAS CORRECT SELECTION, INSTALLATION AND MAINTENANCE Compiled by: Arthur Cameron NOT SO CORRECT SELECTION AND INSTALLATION OF CABLE GLANDS AND JUNCTION BOXES IN HAZARDOUS AREAS

More information

SOP. Working in Confined Spaces

SOP. Working in Confined Spaces Purpose This procedure outlines the requirements for the management of entry into confined spaces in all work areas with the intention of minimising risks to health and safety from any potential hazards

More information

PROCEDURE FOR INITIAL AND PERIODIC INSPECTION POTENTIALLY EXPLOSIVE ATMOSPHERES (HAZARDOUS AREA) ORIGINAL EDITION

PROCEDURE FOR INITIAL AND PERIODIC INSPECTION POTENTIALLY EXPLOSIVE ATMOSPHERES (HAZARDOUS AREA) ORIGINAL EDITION PROCEDURE FOR INITIL ND PERIODIC INSPECTION IN POTENTILLY EXPLOSIVE TMOSPHERES (HZRDOUS RE) ORIGINL EDITION DEC. 1997 This Standard is the property of Iranian Ministry of Petroleum. ll rights are reserved

More information

NZQA unit standard version 5 Page 1 of 5. Describe, develop, and maintain basic ventilation systems for an underground coal mine

NZQA unit standard version 5 Page 1 of 5. Describe, develop, and maintain basic ventilation systems for an underground coal mine Page 1 of 5 Title Describe, develop, and maintain basic ventilation systems for an underground coal mine Level 4 Credits 15 Purpose People credited with this unit standard are able to: describe the basic

More information

BA307C & BA308C Intrinsically safe loop-powered 3½ digit panel mounting indicators issue 9

BA307C & BA308C Intrinsically safe loop-powered 3½ digit panel mounting indicators issue 9 BA307C & BA308C Intrinsically safe loop-powered 3½ digit panel mounting indicators issue 9 Issue: 9 22 nd March 2013 2 CONTENTS 1. Description 2. Operation 3. Intrinsic Safety Certification 3.1 ATEX certificate

More information

COLD-WEATHER APPLICATION OF GAS MIXTURE (SF 6 /N 2, SF 6 /CF 4 ) CIRCUIT BREAKERS: A UTILITY USER S PERSPECTIVE SUMMARY

COLD-WEATHER APPLICATION OF GAS MIXTURE (SF 6 /N 2, SF 6 /CF 4 ) CIRCUIT BREAKERS: A UTILITY USER S PERSPECTIVE SUMMARY COLD-WEATHER APPLICATION OF GAS MIXTURE (SF 6 /N 2, SF 6 /CF 4 ) CIRCUIT BREAKERS: A UTILITY USER S PERSPECTIVE R. L. Middleton, P. Eng. Manitoba Hydro, Winnipeg, Canada SUMMARY Very low temperatures stress

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features 6 mm flush Usable up to SIL 3 acc. to IEC 61508 Application Danger! In safety-related applications the sensor must be operated with a qualified fail safe interface from Pepperl+Fuchs,

More information

Operating Instructions

Operating Instructions Operating Instructions Ex d Enclosures in Light Metal / Flameproof Encapsulation > 8265/0 Empty Enclosure > 8265/4 controller, installed in Ex e enclosure > 8265/5 controller Contents 1 Contents 1 Contents...2

More information

Implementation of Electrical and Instrument Installation in Hazardous Area Classification

Implementation of Electrical and Instrument Installation in Hazardous Area Classification Implementation of Electrical and Instrument Installation in Hazardous Area Classification Rosihan Anwar - Pertamina Hulu Energi ONWJ Phe.pertamina.com IECEx Conference, Jakarta 8-9 August 2018 PERTAMINA,

More information

Design Guideline Planning fieldbus segments in safe and hazardous areas

Design Guideline Planning fieldbus segments in safe and hazardous areas Design Guideline Planning fieldbus segments in safe and hazardous areas Your automation, our passion. Quality Information from a Quality Supplier This technical white paper utilizes Pepperl+Fuchs expertise

More information

Explosive Environment Review

Explosive Environment Review Explosive Environment Review Version 3.0 A Comprehensive Guide to Electronic Weighing Equipment and Hazardous Environments PN 16985 Contents 1.0 Introduction... 1 2.0 Standards... 2 2.1 NFPA 70, National

More information

Thermo Probe, Inc. TP-5 TP-7 TP-8. Instruction Manual English. Switch. Display. Carry Strap. Probe. Ground Clip. Switch. Display.

Thermo Probe, Inc. TP-5 TP-7 TP-8. Instruction Manual English. Switch. Display. Carry Strap. Probe. Ground Clip. Switch. Display. Display Thermo, Inc. Instruction Manual English TP-5 Display TP-7 Display TP-8 1-1 Thermo, Inc. Instructions for use- Models TP-5, TP-7, and TP-8 The manual describes basic function and use of Thermo instruments

More information

SAFETY MANAGEMENT MANUAL Confined Space Entry

SAFETY MANAGEMENT MANUAL Confined Space Entry 1. Purpose The purpose of this procedure is to set forth policies concerning confined space entry both at sea and in port. 2. Responsibility It shall be the responsibility of the Master to ensure that

More information

Material Safety Data Sheet

Material Safety Data Sheet Product Name Supplier Product use MSDS# Date of Preparation/Revision In case of emergency Material Safety Data Sheet Flammable Gas Mixture Argon 1-97.06% / Hydrogen.94-99% Section 1. Chemical product and

More information

Installation of Ballast Water Management Systems

Installation of Ballast Water Management Systems (Sept 2015) (Rev.1 May 2016) Installation of Ballast Water Management Systems 1. Application In addition to the requirements contained in BWM Convention (2004), the following requirements are applied to

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features Comfort series 15 mm flush Accessories MHW 01 Modular mounting bracket MH 04-2057B Mounting aid for VariKont and +U1+ V1-G-N-2M-PUR Female cordset, M12, 2-pin, NAMUR, PUR cable

More information

Wired Communication in Confined Space

Wired Communication in Confined Space Wired Communication in Confined Space What is a confined space? 1 - A confined space is a space that was not designed as a work place but can be occupied to undertake : maintenance work cleaning work inspections

More information

EXPLOSIVE ATMOSPHERES - CLASSIFICATION OF HAZARDOUS AREAS (ZONING) AND SELECTION OF EQUIPMENT

EXPLOSIVE ATMOSPHERES - CLASSIFICATION OF HAZARDOUS AREAS (ZONING) AND SELECTION OF EQUIPMENT EXPLOSIVE ATMOSPHERES - CLASSIFICATION OF HAZARDOUS AREAS (ZONING) AND SELECTION OF EQUIPMENT OVERVIEW ASSESSING THE RISK RELATIONSHIP BETWEEN FIRES AND EXPLOSIONS CLASSIFYING HAZARDOUS AREAS INTO ZONES

More information

FUEL TANK SAFETY / EWIS CONTINUATION TRAINING

FUEL TANK SAFETY / EWIS CONTINUATION TRAINING FUEL TANK SAFETY / EWIS CONTINUATION TRAINING Q1 & Q2 2016 Page 1 of 11 CONTENTS: 1 INTRODUCTION 2 Fuel Tank Safety 3 EWIS Page 2 of 11 1. Introduction The purpose of this module is to highlight industry

More information

Tool Box Talk. Confined Space Entry New Construction Standard (2015)

Tool Box Talk. Confined Space Entry New Construction Standard (2015) Confined Space Entry New Construction Standard (2015) What s all this about Confined Space Entry and how does it affect the construction industry? On May 4, 2015 the Occupation Safety and Health Administration

More information

"CONFINED SPACE ENTRY"

CONFINED SPACE ENTRY PRESENTER'S GUIDE "CONFINED SPACE ENTRY" Training for THE OSHA PERMIT-REQUIRED CONFINED SPACES STANDARDS "Quality Safety and Health Products, for Today...and Tomorrow" OUTLINE OF MAJOR PROGRAM POINTS OUTLINE

More information

Ex-proof solenoid valves with spool position monitor on/off, with inductive proximity sensor - Multicertification ATEX, IECEx, EAC

Ex-proof solenoid valves with spool position monitor on/off, with inductive proximity sensor - Multicertification ATEX, IECEx, EAC www.atos.com Table -2/E Ex-proof solenoid valves with spool position monitor on/off, with inductive proximity sensor - Multicertification TEX, IEEx, E valve body spool ex-proof solenoid ex-proof inductive

More information

HSE guidelines. SMay 2015 ELECTRICAL SAFETY HSE LIFE THE NATIONAL OIL&GAS INDUSTRY STANDARD FOR PROFESSIONALS

HSE guidelines. SMay 2015 ELECTRICAL SAFETY HSE LIFE THE NATIONAL OIL&GAS INDUSTRY STANDARD FOR PROFESSIONALS HSE guidelines SMay 2015 ELECTRICAL SAFETY HSE LIFE THE NATIONAL OIL&GAS INDUSTRY STANDARD FOR PROFESSIONALS Work safely or do not work at all There are strict procedures when working on electrical installations

More information

Innovation Electrical Industry

Innovation Electrical Industry Position Paper Potential for Optimising the Use of SF6 in Switchgear Automotive Industry 4.0 Energy Efficiency Digitalisation 4.0 Innovation Electrical Industry 16 November 2016 ZVEI German Electrical

More information

ATEX and explosive atmospheres

ATEX and explosive atmospheres ATEX and explosive atmospheres Explosive atmospheres in the workplace can be caused by flammable gases, mists or vapours or by combustible dusts. Explosions can cause loss of life and serious injuries

More information

Arc Flash. Safety 21

Arc Flash. Safety 21 Arc Flash Safety 21 Arc Flash Introduction Electrical Hazards Safety Planning De-Energizing Equipment Working Hot Summary Introduction Most people don t think about electricity very much, which is surprising

More information

Arran LED Floodlight Luminaire

Arran LED Floodlight Luminaire Arran LED Floodlight Luminaire INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS Important: Please read these instructions carefully before installing or maintaining this equipment. Good electrical

More information

SWMS No 009 Samark North Qld Pty Ltd ABN : Electrical Contractors License C37121 Page 2 of 4

SWMS No 009 Samark North Qld Pty Ltd ABN : Electrical Contractors License C37121 Page 2 of 4 Samark North Qld Pty Ltd SWMS Manual SWMS No 009 Samark North Qld Pty Ltd ABN : 99 082 98 87 Electrical Contractors License C72 Page 2 of Safe Work Method Statement Title: SWMS:009 Confined Space Work

More information

"CONFINED SPACE ENTRY... A REFRESHER PROGRAM"

CONFINED SPACE ENTRY... A REFRESHER PROGRAM MAJOR PROGRAM POINTS "CONFINED SPACE ENTRY... A REFRESHER PROGRAM" Training for THE OSHA PERMIT-REQUIRED CONFINED SPACES STANDARD Quality Safety and Health Products, for Today...and Tomorrow OUTLINE OF

More information

Advances in Low Voltage Motor Control Center (MCC) Technology Help Reduce Arc-Flash Hazards and Minimize Risks

Advances in Low Voltage Motor Control Center (MCC) Technology Help Reduce Arc-Flash Hazards and Minimize Risks Advances in Low Voltage Motor Control Center (MCC) Technology Help Reduce Arc-Flash Hazards and Minimize Risks Selecting the right MCC equipment leads to improved plant safety, helping protect people and

More information

State University of New York College at Oneonta

State University of New York College at Oneonta State University of New York College at Oneonta CONFINED SPACE ENTRY POLICY - PROCEDURE REVIEWED 05/11/17 CONFINED SPACE ENTRY - WRITTEN PLAN POLICY The State University College at Oneonta is committed

More information

Pressure Switches Application Guideline

Pressure Switches Application Guideline Pressure Switches Application Guideline Product Overview The Fema Pressure Switch product portfolio provides devices suitable for many applications. The portfolio contains Special functions and equipment

More information

CARRIAGE OF DIRECT REDUCED IRON (DRI) BY SEA CHANGES TO THE IMO CODE OF SAFE PRACTICE FOR SOLID BULK CARGO

CARRIAGE OF DIRECT REDUCED IRON (DRI) BY SEA CHANGES TO THE IMO CODE OF SAFE PRACTICE FOR SOLID BULK CARGO The Shipowners Protection Limited St Clare House, 30-33 Minories London EC3N 1BP TO ALL MEMBERS March 2010 Managers of The Shipowners Protection Mutual Protection Limited and Indemnity St Clare House,

More information

Electrical Safety Work Practices

Electrical Safety Work Practices Work Practices I. SCOPE This program covers any SOUTHWESTERN COMMUNITY COLLEGE employee that may work or be exposed to exposed electrical systems: To assure that employees are not exposed to potentially

More information

Improve Process Reliability

Improve Process Reliability Convenient Conductivity Calibration to Meet Pharmacopeia Regulations Pharmacopeias require that conductivity measurement systems be periodically calibrated to ensure their precision. The range of accessories

More information

NZQA Expiring unit standard version 7 Page 1 of 8. Demonstrate knowledge of safe working practices in telecommunications.

NZQA Expiring unit standard version 7 Page 1 of 8. Demonstrate knowledge of safe working practices in telecommunications. Page 1 of 8 Title Demonstrate knowledge of safe working practices in telecommunications Level 2 Credits 4 Purpose This unit standard covers basic instruction in safe working practices in the telecommunications

More information

Inerting System Design for Medium Speed Vertical Spindle Coal Pulverizers TABLE OF CONTENTS

Inerting System Design for Medium Speed Vertical Spindle Coal Pulverizers TABLE OF CONTENTS Inerting System Design for Medium Speed Vertical Spindle Coal Pulverizers The PRB Coal Users Group plans to develop a Design Guide for Mill Inerting as an aid to users when designing a mill inerting system.

More information