Donning Personal Protective Equipment
|
|
- Everett Austin
- 5 years ago
- Views:
Transcription
1
2 Donning Personal Protective Equipment AFC & PSC Basic SCBA The ability to don personal protective clothing NFPA 1001, Standard for Fire Fighter Professional Qualifications 5.1.2, 5.3.1, 5.3.2, 5.3.3, 2013 Edition. Skill Sheet-1 The candidate, given a complete set of PPE, will don full personal protective equipment, according to manufacturer s recommendations. Expected time to complete skill(s) is 1 minute Criteria/Performance Steps: 1. Dons boots, pants, protective hood, coat, helmet, and gloves 2. Properly dons all personal protective equipment (no exposed skin except for facial area, helmet strap is tightened, coat collar is up, and all fasteners are secured) 3. Completes within 1 minute 4. Doffs personal protective clothing and prepares for reuse Score: /4 S c o Evaluator Print Name & Signature: Date Overall Skill Sheet Score Page 1 of 1 Revised- 10/15/13
3 Donning Self-Contained Breathing Apparatus The ability to don self-contained breathing apparatus NFPA 1001, Standard for Fire Fighter Professional Qualifications 5.3.1, 5.3.2, 5.3.3, 2013 Edition. Basic SCBA Skill Sheet- 2 The candidate, wearing personal protective equipment, shall properly don a self-contained breathing apparatus, and activate the PASS alarm. The candidate may use ONE of the following: Over-the-head method, Coat method, or Seat Mount method. Expected time to complete skill(s) is 3 minutes Criteria/Performance Steps: 1. Dons SCBA using one of the listed methods and ensures unit is secured and adjusted properly 2. Dons face piece, attaches regulator (if using waist mount regulator, attaches breathing tube to regulator) inhales activating regulator, holds breath for 5 seconds to ensure there are no leaks CRITICAL POINT 3. Exhales forcefully to ensure exhalation valve is working properly-critical POINT 4. Dons hood, helmet, and gloves and ensures there is no exposed skin CRITICAL POINT 5. Activate PASS alarm-critical POINT Score: /5 S c o Evaluator Print Name & Signature: Date Overall Skill Sheet Score Page 1 of 1 Revised- 10/21/13
4 Inspecting SCBA SCBA is cleaned and maintained NFPA 1001, Standard for Fire Fighter Professional Qualifications, 5.3.1*, 5.5.1, 2013 Edition. Basic SCBA Skill Sheet- 3 The candidate, given a self-contained breathing apparatus, shall demonstrate how to inspect and maintain this unit according to manufacturer s recommendations to ensure the SCBA is ready to use Expected time to complete skill(s) is 3 minutes Criteria/Performance Steps: 1. Checks that cylinder is at least 90% full 2. Checks that all gauges work. Cylinder & regulator gauge should read within 10% of each other 3. Checks to see that low pressure alarm is in working condition CRITICAL POINT 4. Checks to ensure that all hose connections are tight & free of leaks 5. Checks to ensure that the face piece is in good condition & the straps are in the fully extended position 6. Checks to ensure that the harness system is in good condition & that all straps are in the fully extended position 7. Checks to ensure that all valves (e.g. bypass, mainline, exhalation) are operational. Bypass valve should be fully closed. CRITICAL POINT 8. Checks cleanliness of unit Score: /8 S c Evaluator Print Name & Signature: Date Overall Skill Sheet Score Page 1 of 1 Revised- 10/21/13
5 SCBA Emergency Procedures The ability to control breathing and initiate emergency procedures in the event of an SCBA failure. NFPA 1001, Standard for Fire Fighter Professional Qualifications, 5.2.4*, 5.3.1*, 2013 Edition. Basic SCBA Skill Sheet- 4 The candidate, wearing full personal protective equipment and SCBA shall demonstrate controlled breathing techniques and be able to demonstrate the ability to perform an emergency procedure check on his/her selfcontained breathing apparatus. Warning: No emergency breathing procedure is endorsed by manufacturers, NFPA, ANSI, or any other regulating agency. These procedures should be used only as a last resort in life threatening situations. Expected time to complete skill(s) is 3 minutes Criteria/Performance Steps: CONSERVATION OF AIR (CONTROLLED BREATHING) 1. Calls a Mayday - CRITICAL POINT 2. Inhales normally through mouth and exhales normally through nose. 3. Inhales and exhales slowly. 4. Proceeds to exit as quickly as possible. 5. Repeats steps for three minutes - CRITICAL POINT EMERGENCY PROCEDURE CHECK 1. Calls a Mayday - CRITICAL POINT 2. Manually activates PASS device 3. Does NOT remove face piece - CRITICAL POINT 4. Places hand to face piece and regulator and checks bypass valve. 5. Uses bypass or cylinder valve to control air flow (depending on free flow or no flow). 6. Corrects problem if possible. 7. Proceeds to exit as quickly as possible. 8. Repeats steps for three minutes - CRITICAL POINT Score: /5 Score: /8 Evaluator Print Name & Signature: Date Overall Skill Sheet Score Page 1 of 1 Revised- 10/21/13
6 Restricted Openings AFC & PSC Basic SCBA The ability to use SCBA to exit through restricted passages NFPA 1001, Standard for Fire Fighter Professional Qualifications, 5.3.1, 5.3.9, 2013 Edition. Skill Sheet-5 The candidate, wearing full protective equipment including SCBA of his/her choice, shall safely exit an area with a restricted opening using ONE of the listed techniques (vertical or horizontal opening that is too small to accommodate both the firefighter and the SCBA). Expected time to complete skill(s) is 20 minutes Criteria: RESTRICTED OPENINGS - SHIFTING THE SCBA 1. Maintains contact with SCBA CRITICAL POINT 2. Maintains physical, visual, or verbal contact with partner CRITICAL POINT 3. Keeps all PPE intact CRITICAL POINT 4. Checks conditions on other side of passage before entry CRITICAL POINT 5. Loosens shoulder strap and then waist strap 6. Shifts SCBA to one side (depending on which side regulator is on) 7. After obstruction is cleared, repositions SCBA and tightens straps RESTRICTED OPENINGS- BACKWARDS SWIM TECHNIQUE 1. Maintains contact with SCBA CRITICAL POINT 2. Maintains physical, visual, or verbal contact with partner CRITICAL POINT 3. Keeps all PPE intact CRITICAL POINT 4. Checks conditions on other side of passage before entry CRITICAL POINT 5. Sits with back against wall and centered between two obstacles 6. Feet positioned in front of body as far as possible and buttocks raised off ground to proceed through opening 7. Pulls shoulders and elbows into center of body while pushing backwards through the space 8. Once SCBA is clear, the firefighter rotates the body, dipping the shoulder to bring the rest of the body through the obstacle Score: /7 Score: /8 Page 1 of 3 Revised- 08/13/13
7 Restricted Openings The ability to use SCBA to exit through restricted passages 2013 Edition, NFPA 1001, Standard for Fire Fighter Professional Qualifications, 5.3.1*, 5.3.9* Basic SCBA Skill Sheet- 5 The candidate, wearing full protective equipment including SCBA of his/her choice, shall safely exit an area with a restricted opening using ONE of the listed techniques (vertical or horizontal opening that is too small to accommodate both the firefighter and the SCBA). Expected time to complete skill(s) is 20 minutes Criteria: RESTRICTED OPENINGS - FORWARD DIVE TECHNIQUE P F 1. Maintains contact with SCBA CRITICAL POINT 2. Maintains physical, visual, or verbal contact with partner CRITICAL POINT 3. Keeps all PPE intact CRITICAL POINT 4. Checks conditions on other side of passage before entry CRITICAL POINT 5. Centers body between two wall studs and places both arms in front through obstacle, attempting to get elbows past opening 6. Exhales and arms are pulled inward to center of body, allowing firefighter to fall through opening 7. Clears obstacle and uses arms to pull rest of body through opening RESTRICTED OPENINGS - FULL ESCAPE PROCEDURE 1. Maintains contact with SCBA CRITICAL POINT 2. Maintains physical, visual, or verbal contact with partner CRITICAL POINT 3. Keeps all PPE intact CRITICAL POINT 4. Checks conditions on other side of passage before entry CRITICAL POINT 5. While lying to one side, loosens the shoulder straps and removes waist strap 6. Rolls out of the backpack to the side of the regulator and does not lose contact with strap CRITICAL POINT 7. SCBA is rotated with cylinder valve facing away from firefighter and straps are neat and organized to facilitate easy redonning 8. Moves forward keeping SCBA in front and close to body CRITICAL POINT 9. When clear of obstacle, redonns the SCBA by laying out straps and rolling into backpack assembly Score: /7 Score: /9 Page 2 of 3 Revised- 8/13/13
8 Restricted Openings The ability to use SCBA to exit through restricted passages 2013 Edition, NFPA 1001, Standard for Fire Fighter Professional Qualifications, 5.3.1*, 5.3.9* Basic SCBA Skill Sheet- 5 The candidate, wearing full protective equipment including SCBA of his/her choice, shall safely exit an area with a restricted opening using ONE of the listed techniques (vertical or horizontal opening that is too small to accommodate both the firefighter and the SCBA). Expected time to complete skill(s) is 20 minutes Evaluator: Print Name & Signature: Date Overall Skill Sheet Score Candidate: Print Name & Signature: Candidate: Print Name or Candidate # Page 3 of 3 Revised- 10/21/13
9 Changing an Air Cylinder The ability to replace SCBA air cylinders NFPA 1001, Standard for Fire Fighter Professional Qualifications, 5.3.1, 2013 Edition, AFC & PSC Basic SCBA Skill Sheet-6 The candidate, wearing full personal protective equipment, shall demonstrate the proper procedure for changing a SCBA air cylinder using the one person method. The candidate may use any SCBA unit available to his/her department. Expected time to complete skill(s) is 2 minutes Criteria/Performance Steps: Retest P F 1. Doffs unit using proper procedures 2. Closes cylinder valve on the used bottle and bleeds off pressure - CRITICAL POINT 3. Disconnects the high-pressure coupling from the cylinder and puts the hose coupling on the ground directly in line with the cylinder outlet (ensures grit & liquids cannot enter the end of the unprotected high-pressure hose prior to attaching it to the cylinder outlet valve) 4. Releases the cylinder clamp & removes the empty cylinder and places a new cylinder into the backpack 5. Checks cylinder valve opening & the high-pressure hose fitting for debris and checks condition of O-ring CRITICAL POINT 6. Connects high-pressure hose to cylinder valve opening and opens cylinder valve 7. Checks gauges on cylinder & regulator (ensures they are within 10% of each other) Score: /7 Score: /7 Evaluator: Print Name & Signature: Date Overall Skill Sheet Score Page 1 of 1 Revised- 10/21/13
Alabama Fire College Rapid Intervention Crews Instructional JPR Verification Sheet
Alabama Fire College Rapid Intervention Crews Instructional JPR Verification Sheet Full Name: Fire Department: This Instructional JPR Verification Sheet is to be used in conjunction with the Alabama Fire
More informationAlabama Smoke Diver Policies
Policies Class will begin at 8:00 a.m. Tardiness will not be tolerated! First instance of Tardiness will result in positive physical reinforcement (PT). If a candidate has a second tardy, he or she will
More informationIndustrial Fire Brigade: Interior Structural
Industrial Fire Brigade: Interior Structural Skill Sheet Package Based on NFPA 1081: Standard for Industrial Fire Brigade Member, 2012 Edition. Alabama Fire College May 2014 Certification Criteria Interior
More informationBased on NFPA 1001: Standard for Fire Fighter Professional Qualifications, 2013 Edition.
Based on NFPA 1001: Standard for Fire Fighter Professional Qualifications, 2013 Edition. Revised 04/12/2017 Candidate Name (PRINTED) (First, Middle, Last) Course Dates Training Location Candidate Signature
More informationBased on NFPA 1001: Standard for Fire Fighter Professional Qualifications, 2013 Edition.
Based on NFPA 1001: Standard for Fire Fighter Professional Qualifications, 2013 Edition. December 2013 Revised 08/17/2017 Chapter Alabama Fire College and Personnel Standards & Education Commission Fire
More informationCourse Firefighter I. Unit II Safety and Orientation
Course Firefighter I Unit II Safety and Orientation Essential Question Why is proficiency donning and doffing SCBA important for firefighters? TEKS 130.299(c) (2)(C), (10)(B), (11)(A)(C)(E), (14)(A)(B)
More informationPerformance Examination 4100 Sub JAC Handbook
TOPIC: CATEGORY: JAC PERFORMANCE EXAM 24 Extension Ladder POINTS POSSIBLE: 100 TIME ALLOWED: 6 Minutes BEHAVIORAL OBJECTIVE: Condition: Behavior: Standard: An engine with a MMR SCBA mounted in a breathing
More informationFIRE FIGHTER I EMERGENCY PROCEDURES WHEN USING SCBA TOPIC: TIME FRAME: 0:30. Level II LEVEL OF INSTRUCTION:
TOPIC: EMERGENCY PROCEDURES WHEN USING SCBA TIME FRAME: 0:30 LEVEL OF INSTRUCTION: Level II AUTHORITY: 1997 NFPA 1001 3-3.1 and CCR, Title 8, Section 5144 BEHAVIORAL OBJECTIVE: Condition: Behavior: Standard:
More information5.3.2 Respond to an incident, correctly mounting and dismounting an apparatus. FFI -1 Revised 6/9/ Don appropriate PPE.
5.3.2 Respond to an incident, correctly mounting and dismounting an apparatus. FFI -1 STANDARD: 5.3.2 TASK: Safely mount and dismount fire department apparatus PERFORMANCE OUTCOME: The candidate will correctly
More informationMMR Air Mask With. with Quick-Connect Hose
MMR Air Mask With with Quick-Connect Hose Upgrade Kits P/N 10025120 Slide to Connect P/N 10050038 Slide to Connect w/ Solid Cover P/N 10038666 Push To Connect P/N 10050037 Push To Connect w/ Solid Cover
More informationFocus Area Campaign for November 2014 SCBA
Focus Area Campaign for 2014-2015 November 2014 SCBA SMS Reference SBP 13.04 FTM 04.06 FM 13 FM ANX 1,2 &3 and APP 1 H&S 05.04 H&S 06.02 ECM 05.08 ECM 09.03 ECM 14.02 MTM 05.08 Guidance for the FOCUS area
More informationTraining. Level of training on the Scott 4.5 SCBA air pack must be completed in the order stated on the pages below.
Training Employee training is an important part of the respiratory protection program and is essential for correct respirator use. The OSHA respiratory protection standard requires Rio Hondo Fire Academy
More informationBased on NFPA 1081: Standard for Industrial Fire Brigade Member Qualifications.
Based on NFPA 1081: Standard for Industrial Fire Brigade Member Qualifications. Donning Personal Protective Clothing 2007 Edition, NFPA 1081 Chapter 6.2.1b, 7.1.2.1b AFC & PSC Industrial Fire Brigade Skill
More informationCollege of Eastern Idaho. Fire Service Technology IFSAC. Firefighter Certification Program. Firefighter I
College of Eastern Idaho Fire Service Technology IFSAC Firefighter Certification Program The following skills sheets are meant to be printed 2 sided. This allows the candidate to view the instructions
More informationProduct Information News
Product Information News MMR SECOND STAGE REGULATOR VALVE CORE MSA has changed its recommended rebuilding of the MMR Second Stage Regulator s bypass sleeve assembly during the annual inspection. Based
More information2017 GSFA / GAFC FIREFIGHTER S COMPETITION
2017 GSFA / GAFC FIREFIGHTER S COMPETITION Friday, August 25, 2017 400 Foundry Pavilion Athens, Georgia (Located behind the Classic Center) OFFICIAL RULES & REGULATIONS Please review the following rules
More information2018 GEORGIA FIRE SERVICE CONFERENCE FIREFIGHTERS COMPETITION
2018 GEORGIA FIRE SERVICE CONFERENCE FIREFIGHTERS COMPETITION Friday, August 17, 2018 Dalton, Georgia OFFICIAL RULES & REGULATIONS Please review the following rules and regulations for the Georgia Fire
More informationChecklist for care of Respirators
Checklist for care of Respirators Inspect the respirator before and after each use and during cleaning. Inspect equipment designated for "emergency use" at least monthly, and after each use. Replace all
More informationGSFA FIREFIGHTER S COMPETITION 2012 OFFICIAL RULES & REGULATIONS
GSFA FIREFIGHTER S COMPETITION 2012 OFFICIAL RULES & REGULATIONS 1530 HOURS RAPID DRESS QUALIFYING ROUND 1700 HOURS COACHES MEETING 1800 HOURS FIREFIGHTER S COMPETITION BEGINS RULES & REGULATIONS - RAPID
More informationGSFA / GAFC FIREFIGHTER S COMPETITION Friday, September 18, 2015 Summer Waves Water Park 210 S Riverview Dr, Jekyll Island, GA 31527
GSFA / GAFC FIREFIGHTER S COMPETITION - 2015 Friday, September 18, 2015 Summer Waves Water Park 210 S Riverview Dr, Jekyll Island, GA 31527 OFFICIAL RULES & REGULATIONS 1500 HOURS RAPID DRESS QUALIFYING
More informationExtendAire TM II. Intermediate Pressure Accessory Kit USER INSTRUCTIONS
ExtendAire TM II Intermediate Pressure Accessory Kit USER INSTRUCTIONS THIS MANUAL MUST BE CAREFULLY READ AND FOLLOWED BY ALL PERSONS WHO HAVE OR WILL HAVE THE RESPONSIBILITY FOR USING OR SERVICING THIS
More informationFire Apparatus Operator Aircraft Rescue and Fire Fighting
Fire Apparatus Operator Aircraft Rescue and Fire Fighting Skill Sheet Package Based on NFPA 1002: Standard on Fire Apparatus Driver/ Operator Professional Qualifications, 2014 Edition. Alabama Fire College
More informationTOPIC: EVALUATING FIREFIGHTER PROFICIENCY MATERIALS: PERSONAL PROTECTIVE CLOTHING AS REQUIRED FOR EACH EVOLUTION
1 MFRI Drill of the Month INSTRUCTOR GUIDE TOPIC: EVALUATING FIREFIGHTER PROFICIENCY LEVEL OF INSTRUCTION: TIME REQUIRED: SIX HOURS MATERIALS: PERSONAL PROTECTIVE CLOTHING AS REQUIRED FOR EACH EVOLUTION
More informationFlorida Public Service Association, Inc.
Revised 07/2017 Purpose: To encourage public service students to develop the skills to don firefighter protective gear. Description of Event: Competitors will simulate being awakened and prepare for a
More informationGEORGIA DEPARTMENT OF CORRECTIONS Standard Operating Procedures IVN Authority: Effective Date: Page 1 of WETHERINGTON/HODGE 4/01/02
GEORGIA DEPARTMENT OF CORRECTIONS Standard Operating Procedures Functional Area: SUPPORT SERVICES/FIRE SERVICES Subject: OCCUPATIONAL SAFETY & HEALTH/PROTECTIVE CLOTHING AND EQUIPMENT 8 Revises Previous
More informationFire Apparatus Operator: ARFF
Fire Apparatus Operator: ARFF Skill Sheet Package Based on NFPA 1002: Standard on Fire Apparatus Driver/ Operator Professional Qualifications, 2017 Edition. Alabama Fire College November 26, 2018 Alabama
More informationButton style shirt and firefighting gloves are not required. (This will be a requirement in 2019.)
Firefighting (FF) Public Safety Skilled and Technical Sciences Contests Contest Information State Qualifying Exam: Yes National Contest: Yes Participation: Individual Update April 2, 2018 Contest Description
More informationFIRE FIGHTER I NFPA 1001, Chapter 5, 2013 Edition
Official Skill Sheets for Practical Skills Ontario, Canada FIRE FIGHTER I NFPA 1001, Chapter 5, 2013 Edition National Fire Protection Association Standard for Fire Fighter Professional Qualifications Enquiries
More informationLesson Topic 3.1 Approaches & Carries
Lesson Topic 3.1 Approaches & Carries FRONT SURFACE APPROACH Approach survivor Utilizing modified crawl or breast stroke Head out of the water eyes on the survivor Execute quick reverse Arms length away
More informationTESTING SKILLS SAFETY
SAFETY #1 Techniques for Actions When Trapped or Disoriented Subject: Fireground Operations Section 101 NFPA 1001 5.3.5 Firefighter I OBJECTIVE Exit a hazardous area as a team, given vision obscured conditions,
More informationU.S. Patent No. 7,922,246. Patents Pending
U.S. Patent No. 7,922,246 Patents Pending 2 Table of Contents Page General Information... 3 Warnings and Cautions... 4 Tools... 6 SmartDock Parts... 6 Initial Set-Up and Adjustment... 7 Select Valve Retaining
More informationPBCFR Reserve Battalion Combat Skills Check Off
PBCFR Reserve Battalion Combat s Check Off Member s Name: Approved for Combat: Introduction All Palm Beach County Reserve Battalion members who are certified by the State of Florida with a minimum of FF
More informationProtective Envelope and Foam
Note Taking Guide Protective Envelope and Foam Maryland Fire and Rescue Institute University of Maryland Steven T. Edwards Fall 2011 Copyright 2011 by the Maryland Fire and Rescue Institute. All rights
More informationINSTRUCTION MANUAL EBA-75 CLOSED-CIRCUIT ESCAPE RESPIRATOR (CCER) CAPACITY 3
INSTRUCTION MANUAL FOR THE EBA-75 CLOSED-CIRCUIT ESCAPE RESPIRATOR (CCER) CAPACITY 3 Manual Number: NH24053 Revision: A, ECN 3590 December 14, 2015 Page 1 of 13 CONTENTS PAGE INTRODUCTION... 3 GENERAL
More informationCity of Minot Specifications SCBA
January 2018 City of Minot Specifications SCBA The unit described under these specifications shall be the manufacturer s latest SCBA and meet the following minimum specifications. Any deviations from the
More informationHAZARDOUS MATERIALS OPERATIONS NFPA 472, 2008 Edition
5.2 Core Competencies Analyzing the Incident JPR - HMO #1 5.2.1 Surveying the Hazardous Materials/WMD Incidents Revised: June 30, 2011 Standard Area: Competencies Analyzing the Incident STANDARD: 5.2.1.3.2
More informationProtective Envelope and Foam
Note Taking Guide Protective Envelope and Foam Maryland Fire and Rescue Institute University of Maryland Steven T. Edwards, Director Spring 2014 Copyright 2014 by the Maryland Fire and Rescue Institute.
More informationIdaho Fire Service Technology Fire Fighter I
Idaho Fire Service Technology Locate information in AHJ SOPs and Codes Skill Sheet # 1 STANDARD: 5.1.2 TASK: Locate information in AHJ SOP s and Codes PERFORMANCE OUTCOME: The candidate shall be able to
More informationEvaluator Hazardous Material Technician Practical Skills
INDIANA FIRE ACADEMY TRAINING SYSTEM A Division of Indiana Homeland Security Hazardous Material Technician Evaluator Hazardous Material Technician Practical Skills Reference material needed for this course:
More informationPreparation OVERVIEW: Protective Clothing and Equipment Safety Protective clothing Self-contained breathing apparatus
INSTRUCTOR GUIDE COURSE: FIREFIGHTER PRE-BASIC SESSION REFERENCE: 2 TOPIC: PROTECTIVE CLOTHING AND EQUIPMENT LEVEL OF INSTRUCTION: 3.0 TIMRE REQUIRED: 3 HOURS MATERIALS: Personal Protective Clothing Self-Contained
More informationPPE Refresher Using your SCBA
PPE Refresher Using your SCBA Time Requirement: 2-3 hours total (depending on number of participants) Number of Instructors: Minimum of 2 Materials Student materials (participant guide, worksheets) Whiteboard,
More informationKMB 18/28 (BANDMASK) MONTHLY MASK INSPECTION APPENDIX A
KMB 18/28 (BANDMASK) MONTHLY MASK INSPECTION APPENDIX A2.2 08-01-17 This inspection is the minimum recommended maintenance and should be performed at least ONCE A MONTH with Mask(s) in continuous use (used
More informationFIREFIGHTER I MANIPULATIVE SKILL OBJECTIVES GENERAL
10 FIREFIGHTER I MANIPULATIVE SKILL OBJECTIVES PERSONAL PROTECTIVE EQUIPMENT GENERAL 1- Demonstrate the care, inspection, and maintenance of protective clothing assigned or available for use. REFERENCE:
More informationEmergency Vehicle Driver
Emergency Vehicle Driver Skill Sheet Package Based on NFPA 1002: Standard on Fire Apparatus Driver/Operator Professional Qualifications, 2014 Edition. Alabama Fire College February 2016 0 /09/2017 Alabama
More informationMedical Gas Control Panel
Medical Gas Control Panel INSTALLATION & MAINTENANCE MANUAL 255105 (Rev. 6) 2018-04 2 255105 (Rev. 6) 2018-04 1.0 User Responsibilities The information contained in this installation and operation maintenance
More informationCHANHASSEN FIRE DEPARTMENT FIREFIGHTER SKILLS HAZARDOUS MATERIALS PRACTICAL STATIONS
CHANHASSEN FIRE DEPARTMENT FIREFIGHTER SKILLS HAZARDOUS MATERIALS PRACTICAL STATIONS HAZ-MAT- PRODUCT ID & SCENE OPS NFPA 471 3-3 CFD SOG 8.5.4, 9.8 Practical Station ONE The candidate must identify a
More informationWARNING: READ THE GENERAL INFORMATION MANUAL INCLUDED FOR OPERATING AND SAFETY PRECAUTIONS AND OTHER IMPORTANT INFORMATION.
GSR500 Ram Assembly General Description The GSR500 single post lift / ram uses a 3-1/4 air powered cylinder, which is welded to a heavy gauge base. It is normally used to raise and lower a fluid handling
More informationFire Apparatus Operator: Pumper
Fire Apparatus Operator: Pumper Skill Sheet Package Based on NFPA 1002: Standard on Fire Apparatus Driver/Operator Professional Qualifications, 2014 Edition. Alabama Fire College February 2016 revised
More informationSERVICE MANUAL MODEL BA020AMST BREATHING AIR PANEL
SERVICE MANUAL MODEL BA020AMST BREATHING AIR PANEL WARNING: Do not attempt to operate this equipment without first reading and understanding the service manual enclosed with this device. 5/08 2 GENERAL
More informationINSTRUCTION MANUAL FOR EBA MINUTE SELF-CONTAINED SELF RESCUER (SCSR) Manual Number: NH13747 Revision: A, ECN 2384 September 7, 2001
INSTRUCTION MANUAL FOR EBA 6.5 60 MINUTE SELF-CONTAINED SELF RESCUER (SCSR) Manual Number: NH13747 Revision: A, ECN 2384 September 7, 2001 Page 1 of 20 CONTENTS PAGE INTRODUCTION 3 GENERAL INFORMATION..3
More informationFire Apparatus Operator: Pumper
Fire Apparatus Operator: Pumper Skill Sheet Package Based on NFPA 1002: Standard on Fire Apparatus Driver/ Operator Professional Qualifications, 2017 Edition. Alabama Fire College August, 2018 revised
More informationTraining. Testor Training Manual
Training Testor Training Manual Index Section 1 Introduction and Safety Warnings Section 2 Test Procedures Section 3 Test Hoses Section 4 Fault Location 1:1 1.1 Introduction The Dräger Testor test equipment
More informationWest Clinton Fire District
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 West Clinton Fire District Best Practice Respiratory Protection Program Best
More informationPiped Air SCBA Refilling System Standard
WALT WHITE Fire Chief 5770 Freeport Blvd., Suite 200 Sacramento, CA 95822-3516 Ph: (916) 808-1300 Fax: (916) 808-1629 www.sacfire.org Piped Air SCBA Refilling System Standard SCOPE: This specification
More informationSo Others May Live. Job Sheet Booklet. Aviation Rescue Swimmer School Naval Aviation Schools Command NAS Pensacola, FL
\Rescue Swimmers Equipment (LT 4.2) = PT Level 1 (LT 2.1) = Approaches and Carries (LT 3.1) = Releases and Escapes (LT 3.2) = PT Level 2 (LT 2.1) = Aviation Rescue Swimmer School Naval Aviation Schools
More informationHOT SHOT OPERATING INSTRUCTIONS AND OWNER S MANUAL. Model SPC-500. (Propane Torch)
OPERATING INSTRUCTIONS AND OWNER S MANUAL Model # SPC-500 READ INSTRUCTIONS CAREFULLY: Read and follow all instructions. Place instructions in a safe place for future reference. Do not allow anyone who
More information20 10 SCOUT BLAST Fire Explorer Competition
20 10 SCOUT BLAST Fire Explorer Competition Saturday, April 17 th, 2010 0900-1500 Gwinnett County Fair Grounds 2405 Sugarloaf Parkway Lawrenceville, Georgia 30045 Directions: Interstate 85 north or south
More informationAir Mask Low/High Pressure
Air Mask Low/High Pressure USERS MAINTENANCE INSTRUCTIONS THIS MANUAL MUST BE CAREFULLY READ AND FOLLOWED BY ALL PERSONS WHO HAVE OR WILL HAVE THE RESPONSIBILITY FOR USING OR SERVICING THIS AIR MASK. This
More informationSERVICE MANUAL MODEL BA200AA-S1 BREATHING AIR PANEL
SERVICE MANUAL MODEL BA200AA-S1 BREATHING AIR PANEL WARNING: Do not attempt to operate this equipment without first reading and understanding the service manual enclosed with this device. 1/00 2 GENERAL
More informationBermad Pressure Reducing. Model: 42T
Bermad Pressure Reducing Pilot Operated Pressure Control Valve Model: 42T Installation Operation Maintenance Manual (IOM) REV. 27.7.17 Page 1 of 12 Safety First BERMAD believes that the safety of personnel
More informationPerforming Emergency Decontamination
Performing Emergency Decontamination Skill Sheet #1 Standard 5.1.2.2, 5.4.1, Task: Correctly perform emergency decontamination of a victim. A.3.3.17.1 Evaluator Instructions: The candidate shall conduct
More informationProduct Information News September 26, 2003
Product Information News September 26, 2003 LEVER HEIGHT INSPECTION FOR FIREHAWK MMR MSA is announcing a revision to the instructions for the Firehawk MMR Second Stage Regulator as they relate to the air
More informationHotspotter. Model WB-100 Professional Series. Assembly, Testing & Operating Instructions. Safety Information:
Hotspotter Model WB-100 Professional Series Assembly, Testing & Safety Information: Safety publications related to safe practice and use: CSA 2-94 U.S. Requirements for Hand-Held LP Torches for use with
More informationSAR/SCBA SS600-AN-MMA-010
SAR/SCBA SS600-AN-MMA-010 Chapter 2 CHAPTER 2 OPERATION 2.1 INTRODUCTION. Chapter 2 provides a description of the controls, indicators, and operating procedures for the Primary Air Supply Pack (PASP),
More information6A.004 SCBA MAINTENANCE. Policy Number. Page 1 of 5 SCOPE
SCBA MAINTENANCE SCOPE Stoney Point Fire Department Self-contained breathing apparatus provides respiratory protection under conditions of oxygen deficiency or in concentrations of toxic gases immediately
More informationSERVICE MANUAL MODEL BA050BMST BREATHING AIR PANEL
www.modsafe.com SERVICE MANUAL MODEL BA050BMST BREATHING AIR PANEL WARNING: Do not attempt to operate this equipment without first reading and understanding the service manual enclosed with this device.
More informationSERVICE MANUAL MODEL BA600AMST-S1 BREATHING AIR PANEL
SERVICE MANUAL MODEL BA600AMST-S1 BREATHING AIR PANEL WARNING: Do not attempt to operate this equipment without first reading and understanding the service manual enclosed with this device. 2/05 GENERAL
More informationHazardous Materials Technician
Hazardous Materials Technician Skill Sheet Package Based on NFPA 472: Standard for Professional Competence of Responders to Hazardous Materials Incidents, 2013 Edition. Alabama Fire College July 2014 Revised
More informationPINE HILL FIRE DEPARTMENT
PINE HILL FIRE DEPARTMENT STANDARD OPERATIONAL GUIDELINES Operations-22 Subject: PPE (Turnout Gear) Effective Date: 3/1/2008 Revised 11/11/2014 Pages: 1 of 5 The environments in which firefighters perform
More informationChapter 6 Test. Directions: Write the correct letter on the blank before each question.
Chapter 6 Test Name: Date: Directions: Write the correct letter on the blank before each question. Objective 1: Describe the purpose of personal protective equipment. Objective 2: Describe characteristics
More informationSperian Warrior SCBA
Sperian Warrior SCBA Air Cylinder Carbon fiber wrapped aluminum bottle with epoxy overlay. Hydrostatically tested Every 5 years When damaged Suspected to be unsafe (heat exposure, dropped, etc.) Valve
More informationSafe Work Instructions For Oxygen Acetylene Equipment
Safe Work Instructions For Oxygen Acetylene Equipment Policy Sponsor: Assistant Vice President Facilities Management Responsible Unit: Trade Services Approval Date: September 2010 Revisions: January 2018
More informationSERVICE MANUAL MODEL BA100BMST 100 SCFM PORTABLE AIR PANEL
Product Manual MST Portable Air Filtration System SERVICE MANUAL MODEL BA100BMST 100 SCFM PORTABLE AIR PANEL WARNING: Do not attempt to operate this equipment without first reading and understanding the
More informationGuardian Full Face Mask
Guardian Full Face Mask Revised July 28, 2017 South Carolina Aquarium Dive Operations Arnold Postell Dive Safety Officer / Senior Biologist (843) 579-8536 apostell@scaquarium.org Ryan Yuen Assistant Dive
More informationHot Compressed Air Lance Operation Manual. LAB Manufacturing 9483 Reading Road Cincinnati, OH (800)
Hot Compressed Air Lance Operation Manual www.heatlances.com LAB Manufacturing 9483 Reading Road Cincinnati, OH 45215 (800) 776-5830 PARTS CHECK LIST NOTE: Check all fittings & connections prior to operation.
More informationLOS ANGELES COUNTY FIRE DEPARTMENT CONTEXT TRAINING PROGRAM SELF CONTAINED BREATHING APPARATUS
LOS ANGELES COUNTY FIRE DEPARTMENT SELF CONTAINED BREATHING APPARATUS 14 L0S ANGELES COUNTY FIRE DEPARTMENT 15 SELF CONTAINED BREATHING APPARATUS 1. General Information BREATHING APPARATUS SURVIVAIR PANTHER
More informationDBML-60/80 Squeeze Tool
DBML-60/80 Squeeze Tool OPERATORS MANUAL Description The Mustang Model DBML-60/80 Hydraulic squeeze tool has been manufactured since 1995. A Mustang 3 3/4 bore doubleacting cylinder producing 41,000 lbs
More informationCollege of Eastern Idaho. Fire Service Technology IFSAC. Firefighter Certification Program. Hazardous Materials Operations.
College of Eastern Idaho Fire Service Technology IFSAC Firefighter Certification Program The following skills sheets are meant to be printed 2 sided. This allows the candidate to view the instructions
More information1.4 Lift up one of the distressed members legs and place it on your shoulder.
MANAGING MEMBERS IN DISTRESS CHAPTER 3, ADDENDUM 1 November 1, 2011 1. THROUGH THE LEG METHOD 1.1 Locate the waist strap of the SCBA. 1.2 Fully loosen both halves of the waist belt. 1.3 Unbuckle the waist
More informationUtah Fire Service Certification System FIREFIGHTER I
Utah Fire Service Certification System FIREFIGHTER I CERTIFICATION STANDARD JULY 2014 Updated MAY 2018 Utah Fire Service Certification Council Chairperson Scott Spencer, Chief Payson Fire Department Vice-Chairperson
More informationESCONDIDO FIRE DEPARTMENT TRAINING MANUAL ENGINE MODULE SCBA PAGE 1 OF 14 Maintenance Revised
SCBA 10-07-16 PAGE 1 OF 14 The California Occupational Safety and Health Administration requires that: Respirators shall be regularly cleaned after each use or more often if necessary. Those used by more
More informationNIOSH Task Number 18388
National Personal Protective Technology Laboratory Technology Evaluation Branch Certified Product Investigation Program Report of Self-Contained Breathing Apparatus Second Stage Regulators Submitted by
More informationFIRE FIGHTER II - SKILLS PERFORMANCE SHEET
Fire Fighter II Skill Stations: NFPA 1001 2013 Edition Station A Fire Ground Communications & Operations / Interior Attack Coordination MANDATORY STATION Station B Sprinkler Drain/Pressures RANDOM STATION
More informationDRAFT 12/17/03 KMB 18/28 (BANDMASK) OVERHAUL, MAINTENANCE, AND INSPECTION CHECKLIST APPENDIX A
KMB 18/28 (BANDMASK) OVERHAUL, MAINTENANCE, AND INSPECTION CHECKLIST APPENDIX A2.1 12-17-03 THIS INSPECTION AND MAINTENANCE MUST BE PERFORMED AT LEAST ANNUALLY AND AS DICTATED BY CONDITION REVEALED DURING
More informationSURVEYING THE HAZARDOUS MATERIALS INCIDENT
HAZARDOUS MATERIALS TECHNICIAN MANIPULATIVE SKILL OBJECTIVES SURVEYING THE HAZARDOUS MATERIALS INCIDENT 1. Given three hazardous materials, one of which is a solid, one a liquid and one a gas, and the
More informationTABLE OF CONTENTS PART 11 - FIREFIGHTING
TABLE OF CONTENTS PART 11 - FIREFIGHTING Page DEFINITIONS...11-1 APPLICATION...11-1 GENERAL REQUIREMENTS...11-2 PERSONAL PROTECTIVE CLOTHING AND EQUIPMENT FOR FIREFIGHTERS...11-2 SELF-CONTAINED BREATHING
More informationOPERATING INSTRUCTIONS AND OWNER S MANUAL READ AND FOLLOW ALL INSTRUCTIONS
READ INSTRUCTIONS CAREFULLY: OPERATING INSTRUCTIONS AND OWNER S MANUAL Model # MH500LPT MH400PT READ AND FOLLOW ALL INSTRUCTIONS Place instructions in a safe place for future reference. Do not allow anyone
More informationTriPod Safety Coupler Installation & Operating Instructions for Models TP4, TP5, TP6, and TP7
TriPod Safety Coupler Installation & Operating Instructions for Models TP4, TP5, TP6, and TP7 March 2014 Form FVC097 - Rev03 IMPORTANT: KEEP THIS DOCUMENT WITH THE PRODUCT UNTIL IT REACHES THE END USER.
More informationSERVICE MANUAL MODEL BA200AMST-S1 BREATHING AIR PANEL
1 SERVICE MANUAL MODEL BA200AMST-S1 BREATHING AIR PANEL WARNING: Do not attempt to operate this equipment without first reading and understanding the service manual enclosed with this device. 2 GENERAL
More informationInstallation/User s Guide Guide de l Utilisateur Installations- /Gebrauchsanleitung. U.S. Patent No. 7,922,246. Patent Pending
Installation/User s Guide Guide de l Utilisateur Installations- /Gebrauchsanleitung For International Markets U.S. Patent No. 7,922,246 Patent Pending 2 Table of Contents Page General Information... 3
More informationOXY FUEL SYSTEM SET UP & SHUT DOWN PROCEDURE CHECKLIST ACETYLENE FUEL GAS
OXY FUEL SYSTEM SET UP & SHUT DOWN PROCEDURE CHECKLIST ACETYLENE FUEL GAS Items needed for demonstrations: Fire extinguisher PPE (Personal Protective Equipment): o Lab coats/welding jackets o Leather gloves
More informationSOUTH LYON FIRE DEPARTMENT Manual of Procedures 403
PERSONAL PROTECTIVE EQUIPMENT Issued: June 1, 2012 Revised: September 25, 2015 Approved: Chief Mike Kennedy I. SCOPE This procedure applies to all employees required to work in hazardous environments.
More informationAcornVac Vacuum Plumbing Systems - Trouble Shooting Guide
AcornVac Vacuum Plumbing Systems - Trouble Shooting Guide 1. Accumulators Problem Accumulator is overflowing If Accumulator continues to overflow Correction 1. Push and hold the manual activation button
More informationFIRE FIGHTER II SKILL PERFORMANCE CHECK SHEETS NFPA FIRE FIGHTER II SKILL STATION MENU
FIRE FIGHTER II SKILL STATION MENU STATION TASK(S) A FIREGROUND OPERATIONS/FIRE COMMUNICATIONS MANDATORY B SPRINKLER DRAIN/PRESSURES RANDOM C PITOT GAUGE USE RANDOM D INSPECTION/MAINTENANCE: GENERATOR,
More informationMilton Hershey School
Milton Hershey School District 4/5 SkillsUSA Competition, January 15, 2018 CONTEST EQUIPMENT/ TOOL INFORMATION Firefighting CONTEST CHAIRPERSON DC Rodney Sonderman, 717-368-8581 rsonderman@hersheyfire.org
More informationCombination Breathing Apparatus
and Combination Breathing Apparatus ULTRAVUE FACEPIECE TAL 502 (L) Rev. 0 MSA 2005 Prnt. Spec. 10000005389 (I) Mat. 10064385 Doc. 10064385 ULTRAVUE FACEPIECE COMPONENTS Item Part No. Description 800509
More informationST53SD. Self Contained Breathing Apparatus. User Manual
Self Contained Breathing Apparatus User Manual User Manual for the (Short Duration) Self Contained Breathing Apparatus WARNING Disassembly of the components beyond the procedures described herein shall
More information( SC) NOTE: KMDSI strongly recommends that all repairs be performed by trained Personnel.
KIRBY MORGAN SUPERLITE DEEP SEA DIVING HELMET MODELS 17 A/B, 17C, 17K, & KM 37, KM 47, KM 57, KM 77 & KM 97 MONTHLY INSPECTION AND MAINTENANCE CHECKLIST Appendix A2.2 (10-2-2016 SC) This inspection is
More informationLPG SAFETY INFORMATION. Kwik-Gas. Safety Manual. Less talk more energy
LPG SAFETY INFORMATION Kwik-Gas Safety Manual Less talk more energy CONTENTS Introduction to the Kwik-Gas program 2 Emergency and contact information 2 Emergency procedures 3 First aid Instructions for
More informationPeninsula Dental Social Enterprise (PDSE)
Peninsula Dental Social Enterprise (PDSE) Medical Gas Policy Version 3.0 Date approved: August 2018 Approved by: The Board Review due: August 2021 Policy will be updated as required in response to a change
More information