1 Des Plaines Fire Dept. Engineer Program Lieutenants Palenik, Gross, Owen, Butenschoen, Engineer Felde

2 New Developments 1. Laminated fluid specs on the rigs 2. Maintenance repair request updates 3. Locations for reserve apparatus 4. Engineer policy revisions 5. Foam operations changes

3 2015 Engineer Reviews and Test Dates Hydraulics Feb. 4-6 Driving April Engine Ops May 6-8 Truck Ops Sept 2-4 Vehicle Maintenance Oct

4 2015 Test Dates Written and Driving September Practicals September Individuals challenging for the rank order list will test the first day each week. E62 and TW61 will be used 4

5 2015 Hydraulics 1. FH code: Pump Ref. 1 to log today s class 2. Review PowerPoint presentation 3. Review new developments 4. Review class A foam 5. Hydraulics problem solving 5

6 Laminated Fluid Charts 6

7 Maintenance Requests 7

8 8

9 FDC Hose Pack Right side rear compartment 9

10 Stored position 10

11 2 spanner wrenches located inside pack 11

12 Trigate 12

13 Loss Factors Trigate = 10 psi FDC Hose Pack = 10 psi 13

14 Reserve Rig Locations Engine 64 station 61 Ambulance 65 station 62 Ambulance 64 station 63 (bariatric capable) Tower 64 EMA garage Engine 65 EMA garage Squad 55 EMA garage (outside) 14

15 Vehicle color codes E61 E62 E63 E64 WHITE E65 TW61 BLACK TW63 TW64 15

16 Communications 1. Using positions vs. names. 2. Terms: shut down, idle down, good hydrant, positive water. 3. Engineer calls when he s ready to receive relay. 4. Use Class A system; valuable tool.

17 Water Measurements 1 cubic ft. of water weighs? lbs. 1 cubic ft. of water contains.? cubic in. 1 cubic ft. of water contains.? gallons 1 gallon of water weighs...? lbs. 1 gallon of water contains.? cubic in. 1 gallon of water converts to approximately 200 ft. 3 of steam

18 Water Measurements 1 cubic ft. of water weighs 62.5 lbs. 1 cubic ft. of water contains cubic in. 1 cubic ft. of water contains. 7.5 gallons 1 gallon of water weighs lbs. 1 gallon of water contains. 231 cubic in. 1 gallon of water converts to approximately 200 ft. 3 of steam

19 Head & Atmospheric Pressure 1 ft. of water exerts a back pressure of...? psi 1 psi will elevate water...? ft. Atmospheric pressure at sea level...? psi Maximum lift = 34' Practical = 20' (Atmospheric pressure) x (Number of ft. each psi lifts water) 1" mercury =?' lift

20 Head & Atmospheric Pressure 1 ft. of water exerts a back pressure of psi 1 psi will elevate water ft. Atmospheric pressure at sea level psi Maximum lift = 34' Practical = 20' (Atmospheric pressure) x (Number of ft. each psi lifts water) 1" mercury = 1.13' lift

21 Available Water 21

22 Estimating Available Water 1. Note the static reading. 2. Note the drop after discharging the first line. 3. Multiply the initial drop by the square of the desired number of lines to see if the original flow may be doubled, tripled, etc. Multiply by 4 if doubling lines / flow Multiply by 9 if tripling lines / flow Multiply by 16 if quadrupling lines / flow Multiply by 25 if quintupling lines / flow

23 Estimating Available Water 4. Subtract total drop from original static pressure, but do not allow the compound gauge to fall below 10 psi. 5. Multiplier from #3 (total number of lines) and your original flow rate will determine total flow. Assume 50 psi static in Des Plaines.

24 Calculating Available Water from a Hydrant Line GPM Calculation psi drop initial drop =4; 4x3 psi (initial drop) =9; 9x3 psi (initial drop) =16; 16x3 psi (initial drop) =25; 25x3 psi (initial drop) 75 24

25 Recirculating Water 1. How can it be done? Options? 2. When should it be done? 25

26 Pump Tests Pre-service tests Certification (acceptance) tests Service tests Pump tests

27 Certification and Service Tests Test Times % of Rated Certification Service Volume Pressure? hr.? mins.? %? psi? hr.? mins.? %? psi? hr.? mins.? %? psi? mins.?? %? psi 27

28 Certification and Service Tests Test Times % of Rated Certification Service Volume Pressure 2 hrs. 20 mins. 100% 150 psi ½ hr. 10 mins. 70% 200 psi ½ hr. 10 mins. 50% 250 psi 10 mins. * 100% 165 psi (* Just long enough to get readings; overload or "spurt" test) 28

29 Pump Tests 100% 150 psi net pump pressure 70% 200 psi net pump pressure 50% 250 psi net pump pressure 100% 165 psi net pump pressure (spurt test)

30 Net Engine Pressure Net engine pressure (NEP) is the measurement of the total work performed by the pump To lift water into the pump To discharge water from the pump Allowances are made for Friction loss in intake hose Height of lift

31 NEP of a Positive Pressure Water Source No work is being performed on the suction side of the pump NEP = pump discharge pressure (PDP) intake pressure (IP) (or) NEP = master discharge gauge reading compound gauge reading

32 Hand Lines / Master Streams Handlines flow up to and including 350 GPM Master streams flow over 350 GPM Nozzle pressures Smooth bore Handline = 50 psi or 75psi Master stream= 80 psi Fog (combination) Handline = 50psi or 75psi Master stream= 100psi

33 Angle of Deflection & Two variables Air resistance Effective Reach Air resistance increases at an accelerated rate as the pressure is raised with the same tip Gravity

34 Angle of Deflection & Effective Reach Greatest horizontal reach occurs at elevations of degrees Maximum effective vertical reach of fire stream occurs at degrees The 3 rd floor may be said to be the highest floor to which streams may be thrown effectively from street level Moderate head and tail winds decrease reach 10% to 15%

35 Formula for measuring penetration into building? Feet from building # of floor going into

36 One-Eighth Inch (⅛") Rule ⅛" change in nozzle diameter at 50 psi nozzle pressure changes the flow by approximately 50 GPM ⅛" change in nozzle diameter at 80 psi (or 75 psi on a handline) nozzle pressure changes the flow by approximately 100 GPM up to and including 2" tips

37 Solid Stream Nozzles Hand Lines Tip size GPM (at 50 psi nozzle pressure) ⅞" 160 * 1⅛" 250 1¼"

38 Solid Stream Nozzles Master Streams Tip size GPM (at 80 psi nozzle pressure) 1¼" 400 (75 psi) 1⅜" 500 1½" 600 1⅝" 700 1¾" 800 1⅞" 900 2"

39 Friction Loss per 100' of Hose Q = GPM / 100 Hose size Friction Loss Formula 2" (2Q 2 + Q) x 3 2½" (2Q 2 + Q) 3" (2Q 2 + Q) x.4 4" (2Q 2 + Q) x.1 5" (2Q 2 + Q) x.03 39

40 Friction Loss per 100' DPFD 2" =? psi per 100' at 160 GPM DPFD 2" =? psi per 100' at 200 GPM DPFD 2" =? psi per 100' at 250 GPM 160 GPM through 2½" =? psi per 100' 160 GPM through 3" =? psi per 100' (ambulance 73 ) What nozzle/pack should NOT have a stream shaper on it?

41 Friction Loss per 100' DPFD 2" = 20 psi per 100' at 160 GPM DPFD 2" = 30 psi per 100' at 200 GPM DPFD 2" = 55 psi per 100' at 250 GPM 160 GPM through 2½" = 7 psi per 100' 160 GPM through 3" = 3 psi per 100' (ambulance 73 ) What nozzle/pack should NOT have a stream shaper on it? (Stairwell pack)

42 Field Hydraulics 250 GPM nozzle on a 2½" line =? lbs. per 100' friction loss?

43 Field Hydraulics 250 GPM nozzle on a 2½" line = 15 lbs. per 100' friction loss.

44 Elevation Add 5 psi for each floor of elevation (exclude one floor) Subtract 5 psi for each floor below grade

45 Appliances Add? psi for standpipe system with siamese Add? psi for gated wyes & siamese Add? psi for relay operations Add? psi for deluge gun

46 Appliances Add 25 psi for standpipe system with siamese Add 10 psi for gated wyes & siamese Add 20 psi for relay operations Add 20 psi for deluge gun

47 Right or left out of the station? 47

48 Sprinkler Systems Combination Sprinkler systems shall be maintained at 150 psi pump discharge pressure. Why is that? If heads are flowing and we have 2" lines in place, check gauge at wye for correct psi: 160 gpm = 90 psi 200 gpm = 130 psi 250 gpm = 140 psi At lower floors you may have to gate down the outlet, NOT the wye handle.

49 Pressure reducing valves (PRVs) PRVs- Kingston on River Rd set at 130 psi. Check pressure gauge at the wye; give info to your officer. At lower levels you may have to gate the system. Per NFPA 14: PRVs are required when static system pressure is over 175psi. Field adjustable means nothing to us under fire conditions.

50 PRV at Kingston 50

51 Not Field Adjustable 51

52 Hydrant Residual Pressure Recommended minimum of 10 psi should be maintained on the compound gauge when taking water from a hydrant

53 Transfer Valve Settings Pump in CAPACITY when you are going to discharge over 50% of your pump s capacity Pump in PRESSURE when you are going to develop a net pump pressure over 200 psi

54 Friction Loss per 100' (psi) 2½" Hose: (2Q 2 +Q) GPM Q calculation FL Formula FL psi / 100' /100 = 2 (2 x 2 2 ) + 2 = /100 = 3 (2 x 3 2 ) + 3 = /100 = 4 (2 x 4 2 ) + 4 = /100 = 5 (2 x 5 2 ) + 5 = /100 = 6 (2 x 6 2 ) + 6 = /100 = 7 (2 x 7 2 ) + 7 = /100 = 8 (2 x 8 2 ) + 8 = /100 = 9 (2 x 9 2 ) + 9 = /100 = 10 (2 x 10 2 ) + 10 =

55 Friction Loss per 100' (psi) 3" Hose: (2Q 2 +Q) x.4 GPM Q calculation FL Formula FL psi / 100' /100 = 2 [(2 x 2 2 ) + 2] x.4 = /100 = 3 [(2 x 3 2 ) + 3] x.4 = /100 = 4 [(2 x 4 2 ) + 4] x.4 = /100 = 5 [(2 x 5 2 ) + 5] x.4 = /100 = 6 [(2 x 6 2 ) + 6] x.4 = /100 = 7 [(2 x 7 2 ) + 7] x.4 = /100 = 8 [(2 x 8 2 ) + 8] x.4 = /100 = 9 [(2 x 9 2 ) + 9] x.4 = /100 = 10 [(2 x 10 2 ) + 10] x.4 =

56 Friction Loss per 100' (psi) 4" Hose: (2Q 2 +Q) x.1 GPM Q calculation FL Formula FL psi / 100' /100 = 2 [(2 x 2 2 ) + 2] x.1 = /100 = 3 [(2 x 3 2 ) + 3] x.1 = /100 = 4 [(2 x 4 2 ) + 4] x.1 = /100 = 5 [(2 x 5 2 ) + 5] x.1 = /100 = 6 [(2 x 6 2 ) + 6] x.1 = /100 = 7 [(2 x 7 2 ) + 7] x.1 = /100 = 8 [(2 x 8 2 ) + 8] x.1 = /100 = 9 [(2 x 9 2 ) + 9] x.1 = /100 = 10 [(2 x 10 2 ) + 10] x.1 =

57 Friction Loss per 100' (psi) 5" Hose: (2Q 2 +Q) x.03 GPM Q calculation FL Formula FL psi / 100' /100 = 2 [(2 x 2 2 ) + 2] x.03 = /100 = 3 [(2 x 3 2 ) + 3] x.03 = /100 = 4 [(2 x 4 2 ) + 4] x.03 = /100 = 5 [(2 x 5 2 ) + 5] x.03 = /100 = 6 [(2 x 6 2 ) + 6] x.03 = /100 = 7 [(2 x 7 2 ) + 7] x.03 = /100 = 8 [(2 x 8 2 ) + 8] x.03 = /100 = 9 [(2 x 9 2 ) + 9] x.03 = /100 = 10 [(2 x 10 2 ) + 10] x.03 =

58 How can we supply it? 58

59 How do we supply two? Discussion At what pressure will a Trigate s relief valve open? 59

60 How do we supply two? Discussion At what pressure will a Trigate s relief valve open? 230 psi 60

61 Supply & Support of Sprinklers & Standpipes Indicators that you are not getting into a sprinkler or standpipe system with a supply line: In warm, humid weather, lack of condensation on hose coupling Discharge port & hose butt supplying the line is or becomes warm Lack of drop in residual pressure on the compound gauge as this line is charged Inability to gate & feather various pressures on the discharge port

62 Supplying a Standpipe System If the fire department connection is not usable: 1. Stretch a line from the pumper to a gated outlet on the first floor. 2. Remove any house lines, reducer connections, and/or pressure reducers. 3. Connect the pumper supply to the discharge outlet using a double female adapter. 4. When water is started in the supply line, the outlet valve is opened fully to allow water to flow into the riser.

63 Supplying a Standpipe System No fire dept. connection (continued) Why do we want to be on positive water versus sending tank water? Are outlets open? Broken? Additional lines can be similarly stretched to hose outlets on other floors.

64 Battalion 61 64

65 4" pipe thread X 5" Stortz 65

66 Fire Service Basic Hydraulics Siamese operations Siamesing lines is one way of reducing the excessive friction loss created by large volume lines When it becomes necessary to siamese: Divide the GPM by the number of lines the pump is supplying Compute the friction loss for 1 line at the reduced GPM flow & disregard the other lines All that remains is to add either the nozzle pressure if supplying a deluge gun or 20 psi for residual pressure if supplying another Engine If supplying a deluge gun flowing 800 GPM 400' from the Engine

67 Equal Size Lines Divide the total GPM by two lines. This will give 400 GPM through each 3" line. Compute the friction loss for one line of 3" hose delivering 400 GPM: (2 x 4 2 ) + 4 = 36 x.4 = 14.4 or 15 lbs. F.L. per 100' of hose Multiply the F.L. for 100' by the length of the lay in hundreds of feet 15 x 4 = 60 psi F.L. for the total lay To the 60 lbs. F.L. add 80 lbs. NP + 20 lbs. approximate loss for deluge set and this will the engine discharge pressure.

68 Unequal Size Lines Divide the total GPM by two lines, this will give 400 GPM through each line Compute the friction loss for one line of 2½" hose and one line of 3" hose each delivering 400 GPM (2 x 4 2 ) + 4 = 36 lbs. F.L. per 100' of 2½" hose (2 x 4 2 ) + 4 = 36 x.4 = 14.4 (or 15) lbs. F.L. per 100' of 3" hose Add the Two F.L. answers together & divide by two = 51 2 = 25.5 lbs. F.L. per 100' of hose

69 Unequal Size Lines Multiply the F.L. for 100' by the length of the lay in hundreds of feet 25.5 x 4 = 102 lbs. F.L. for the total lay To the 102 lbs. F.L. add 80 lbs. N.P lbs. approximate F.L. in deluge set 2½" / 3" split bed field hydraulics: Total GPM F.L. per 100'

70 Fire Service Basic Hydraulics Wye operations Common & are used, in one way or another, on just about any fire of consequence Uses: Extend hand lines to the fire where the reach is too long for a preconnect Used for overhaul from 2½" lines rather than laying longer & additional 2" lines

71 Wyed Line Operations Example: 400' of 3" hose wyed into two 200' lengths of 2½" hose, each with a 250 GPM smooth bore nozzle. 1. Total the GPM from both 2½" lines. This is the GPM for the 3" supply line: = 500 GPM 2. Compute the friction loss for the 3" supply line: [(2 x 5 2 ) + 5] x.4 = 22 psi per 100'; 4 x 22 = 88 psi total 3. Figure the friction loss in a single 2½" line: (2 x ) = 15 psi per 100'; 2 x 15 = 30 psi total 4. Add your tip pressure (50) and wye FL (10) to the hose FLs: 50 (tip) + 30 (FL 2½") + 10 (wye) + 88 (FL 3 ) =

72 Friction Loss Calculations When it is necessary to supply a pre-piped waterway: Supply the water to the pump inlets or aerial intake. When bypassing the pump & supplying the total operation you should know the intended tip size in order to calculate the pressure (loss factor) and determine the number of supply lines and their diameter.

73 Friction Loss Calculations Loss factor for pre-piped waterways will include the friction loss in the: Intake (saddle) at the GPM flow provided Piping Turret gun Standard loss factor for pre-piped waterways on DPFD trucks: 1⅜"=125, 1½"=130, 1¾"=145, 2"=165, 2¼"=185, Combination = 150psi

74 Friction Loss Calculations Ways to supply a pre-piped waterway: Ladder truck pumps through internal piping to ladder Ladder truck pumps through hose into the ladder intake Engine company pumps into ladder intake Relay to ladder truck pump operator (refer to relay operations)

75 Snorkel Operations Three questions to ask: Where do you want the water (pump or saddle) Tip size (GPM) Loss factor includes saddle, piping and gun 6" waterway = 35 psi loss factor 4" waterway = 80 psi loss factor * (desirable climbing angles = 35 to 80 ) Add 25 psi for elevation Add 80 psi for NP

76 General Operations for a Centrifugal Fire Pump Designed for a specific duty & ordinarily will perform this duty satisfactorily over a long period of time If pump will not prime or loses prime Air Leaks Faulty Connection Faulty pump packing Leaky pump gaskets

77 General Operations for a Centrifugal Fire Pump Pump will not prime or loses prime (continued) Dirt in suction screens Engine speed too low Primer not operated long enough Lack of oil primer reservoir

78 Prime Time 1500 GPM or greater = 45 seconds Less than 1500 GPM = 30 seconds

79 Hydrant Colors GPM (4") = GPM (6") = GPM (8") = GPM (10"+) =

80 Various Numbers EP for 160 GPM =? psi EP for 200 GPM =? psi EP for 250 GPM =? psi EP for piercing nozzle =? psi EP for trash 160 GPM =? psi EP for trash 200 GPM =? psi Eductor intake pressure =? psi Stairwell 160 GPM =? Stairwell 200 GPM =? Stairwell 250 GPM =?

81 Various Numbers EP for 160 GPM = 100 psi EP for 200 GPM = 140 psi EP for 250 GPM = 160 psi EP for piercing nozzle = 225 psi EP for trash 160 GPM = 70 psi EP for trash 200 GPM = 105 psi Eductor intake pressure = 200 psi Stairwell 160 GPM = 115 Stairwell 200 GPM = 155 Stairwell 250 GPM = 167.5

82 Various Numbers (continued) SWP off the tower at 160 GPM =? psi SWP off the tower at 200 GPM =? psi 1⅛" or combination at 50 psi =? GPM 1⅛" or combination at 75 psi =? GPM 1¼" at 50 psi =? GPM 1¼" at 75 psi =? GPM

83 Various Numbers (continued) SWP off the tower at 160 GPM = 80 psi SWP off the tower at 200 GPM = 120 psi 1⅛" or combination at 50 psi = 250 GPM 1⅛" or combination at 75 psi = 300 GPM 1¼" at 50 psi = 300 GPM 1¼" at 75 psi = 400 GPM

84 Various Numbers (continued) ⅞" skid 160 GPM =? psi ⅞" skid 200 GPM =? psi 1⅛" skid 250 GPM =? psi RAM 400 GPM =? psi RAM 500 GPM =? psi

85 Various Numbers (continued) ⅞" skid 160 GPM = 90 psi ⅞" skid 200 GPM = 130 psi 1⅛" skid 250 GPM = psi RAM 400 GPM = 50 psi (+10 gun) RAM 500 GPM = 75 psi (+10 gun)

86 RAM Nozzle 86

87 Husky Class A System 87

88 Husky Foam System Normal Class A operations 1. Turn foam system ON with control switch on Red Husky panel. 2. Open water discharge valve and begin to flow from hose line. 3. Normal default is Class A onboard 0.3%. You are now making foam. 4. When beginning overhaul phase, turn the system OFF; use the foam in the hose for mop up.

89 Husky Foam System To Shut Down after Class A Operations 1. Turn the foam system OFF with control switch on Red Husky control panel. 2. Open the water discharge valve on the discharge(s) that were used and begin to flow from the hose line(s) until the water runs clear. 3. Disengage the water pump and open both manifold drains to relieve any trapped pressure. 4. Close the manifold drains. The system is now ready to be put back in service. 5. Use the DISPLAY button to scroll through to Total Class A Used. Note the amount used and the date in the hose record book.

90 Draft Class B 1. Turn foam system ON with control switch on Red Husky control panel (if system not already in operation). (Have B buckets and pick-up tube ready). 2. Open water discharge valve and begin to flow water. 3. Push MODE button on Red Husky control panel until DRAFT CLASS B comes up, hit ENTER to make selection. An automatic flush will occur for 15 seconds. (Water must be flowing to prevent pressure buildup). Put pickup tube in pail and open foam inlet valve to draft foam. 4. You are now making Class B foam solution.

91 Shut Down Class B 1. Continue flowing water through discharge(s) used. 2. From the foam inlet, draft clear water from a 5- gallon bucket. 3. Continue drafting water and flowing through discharges until they run clear. Drop down to single discharge line. 4. On Red Husky panel, press MODE button until CLASS A FOAM appears. Press ENTER. An automatic flush will occur.

92 Shut down Class B 5. After the automatic flush, the system will begin pumping Class A foam. Continue flowing until foam appears at the tip. 6. Shut off Husky system. Continue flowing through discharge until it is again clear of foam. 7. Disengage water pump and open all manifold drains to relieve any trapped pressure. 8. Close manifold drains (and foam inlet). System is ready to be put back in service.

93 Filling Class A Tank 1. Connect draft hose to foam inlet connection, then open the foam inlet valve. Place hose in square Class A bucket(s). 2. Turn the selector valve to the TANK FILL position (up).

94 94

95 95

96 Filling Class A Tank 3. Turn foam system ON with control switch on Red Husky panel. 4. Press the MODE button until display reads TANK A FILL. (Full tank will read TANK A FULL. ) 5. Press ENTER. The display should read TANK A FILL.

97 Filling Class A Tank 6. Once the tank has reached the upper float switch and automatically shut off the fill process, TANK A FULL will briefly appear on the screen and then switch to CHECK SELECTOR VALVE.

98 Filling Class A Tank 7. Return the selector valve to the INJECT MODE position.(down) NOTE: To reduce entrance of air into system the operator should be prepared to transfer the pick-up tube from one pail to the next before the pail is completely empty.

99 Filling Class A Tank 8. Turn off foam system. Take engine out of pump and open both manifold drains. Close manifolds drains when pressure has been relieved. 9. Rinse out pick-up hose with water. NOTE: Any time engine is put into pump, both manifold drains should be relieved of pressure after system is taken back out of pump.

100 Foam Calculations Husky 10 / Husky 12 Capacities (10 GPM / 12 GPM foam concentrate) 6% x 166 gpm = 10 GPM foam concentrate 3% x 333 gpm = 10 1% x 1000 gpm = 10* 0.5% x 2000 gpm = 10* 0.3% x 3333 gpm = 10 (theoretical) (Husky 10) 0.3% x 4000 gpm = 12 (theoretical) (Husky 12) 1 gal. finished foam.003 gal. foam concentrate * Depending on plumbing 0.3% = 8,333 gallons finished foam x 25 gals. foam concentrate = 8333 gals. finished foam

101 Truck Hydraulics 101

102 Truck Capacities Rig # Water Tank 5" Bedded Hose TW gal. 200 ft. 102

103 We Are Proud of Our Engineers

ESCONDIDO FIRE DEPT TRAINING MANUAL Section DRIVER OPERATOR Page 1 of 14 Hydraulics Revised

ESCONDIDO FIRE DEPT TRAINING MANUAL Section DRIVER OPERATOR Page 1 of 14 Hydraulics Revised DRIVER OPERATOR Page 1 of 14 HYDRAULICS Hydraulics applied in the dynamic fire ground environment is an art that comes with study and experience. The following describes the factors that must be mastered

More information

FIREGROUND HYDRAULICS

FIREGROUND HYDRAULICS INTRODUCTION This section is designed to give pump operators a quick and fairly easy process for determining fire ground hydraulics. Supplying water is a critical part of the control, and the efficient

More information

FIRE LOGISTICS AND MATH EDUCATION A Rumpke Public Outreach Program

FIRE LOGISTICS AND MATH EDUCATION A Rumpke Public Outreach Program FIRE LOGISTICS AND MATH EDUCATION A Rumpke Public Outreach Program Welcome & Introductions Identify emergency exits to all participants. Identify location of restroom facilities. Cover any other related

More information

Apparatus Operator Refresher Training Program

Apparatus Operator Refresher Training Program Division of Training In-Service Training Program Apparatus Operator Refresher Training Program 1 Single Engine / Single Line Operation Refresher Evolution #1 Objective: Charging single handlines at correct

More information

PHILADELPHIA FIRE DEPARTMENT HIGH PRESSURE FIRE HYDRANT SYSTEM PFD TRAINING MANUAL SUPPLEMENT ENGINE PRACTICES SUPPLEMENT 101 PAGE 1

PHILADELPHIA FIRE DEPARTMENT HIGH PRESSURE FIRE HYDRANT SYSTEM PFD TRAINING MANUAL SUPPLEMENT ENGINE PRACTICES SUPPLEMENT 101 PAGE 1 PHILADELPHIA FIRE DEPARTMENT HIGH PRESSURE FIRE HYDRANT SYSTEM PFD TRAINING MANUAL SUPPLEMENT ENGINE PRACTICES SUPPLEMENT 101 PAGE 1 SUPPLEMENT 101 101. HIGH PRESSURE FIRE HYDRANT SYSTEM The High Pressure

More information

TurboDraft Fire Eductor

TurboDraft Fire Eductor TurboDraft Fire Eductor Operating Manual Introduction The TurboDraft is designed to be used for rural water supply operations. Many of us take for granted that there is a fire hydrant on every corner.

More information

Apparatus Operator/Pumper

Apparatus Operator/Pumper Skill Number: AOP-1 Operate Fixed Systems Objective: 4.3.7 (A) (B) 1. The candidate shall be provided with the equipment to complete this objective including apparatus. 2. The candidate uses safety precautions.

More information

TurboDraft. Fire Eductor Operating Instructions.

TurboDraft. Fire Eductor Operating Instructions. TurboDraft Fire Eductor Operating Instructions 1234djfkjldfjlkdjfklsdjlkjfdslkjfsd Table of Contents Description Page Introduction........ 1 Safety Guidelines... 2 Care and Maintenance... 3 TurboDraft

More information

Idaho Fire Service Technology Pumping Apparatus Driver/Operator Skill Sheet: 1

Idaho Fire Service Technology Pumping Apparatus Driver/Operator Skill Sheet: 1 Skill Sheet: 1 Standard 4.2.1, 4.2.2 Task: Perform and document routine test, inspection and servicing functions on specified systems and components. Performance Outcome: Given a fire department pumping

More information

Pumping Apparatus Driver/Operator Apparatus Testing. Chapter Test. Directions: Write the correct letter on the blank before each question.

Pumping Apparatus Driver/Operator Apparatus Testing. Chapter Test. Directions: Write the correct letter on the blank before each question. Chapter 15 Test Name: Date: Directions: Write the correct letter on the blank before each question. Objective 1: Distinguish among preperformance tests for pumping apparatus. 1. Which standard is commonly

More information

Colorado Division of Fire Prevention & Control Driver Operator Pumper JPRs (NFPA 1002, 2014 Edition)

Colorado Division of Fire Prevention & Control Driver Operator Pumper JPRs (NFPA 1002, 2014 Edition) Colorado Division of Fire Prevention & Control Driver Operator Pumper JPRs ( Edition) JPR # Task Initial Certification JPR Requirement: 15 Mandatory Renewal JPR Requirement: 100% of All JPRs (including

More information

Driver Operator Pumps: Basic Pump Operations

Driver Operator Pumps: Basic Pump Operations Driver Operator Pumps: Basic Pump Operations 5 Skills Total NFPA 1002, Standard for Driver Operator Professional Qualifications, 2014 Edition Driver Operator Pumps: Basic Pump Operations Skills Book NFPA

More information

Flow Material Length. Weight GPM LPM. Style 3095

Flow Material Length. Weight GPM LPM. Style 3095 Akron Municipal Eductors feature a large, easy to read, and removable metering dial with infinite settings between 0% and 6%. Detents at 1 4, 1 2, 1, 3 and 6%. The Eductors are rated to flow at 200 psi

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S Page 1 of 13 1. DESCRIPTION The Viking 6 Model G-6000 Dry Valve Riser Assembly consists of a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry sprinkler

More information

TECHNICAL DATA. Q= Cv S

TECHNICAL DATA. Q= Cv S Page 1 of 13 1. DESCRIPTION The Viking 4 inch Model G-4000 Dry Valve Riser Assembly consists of a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry

More information

Chapter 16 Test. Directions: Write the correct letter on the blank before each question.

Chapter 16 Test. Directions: Write the correct letter on the blank before each question. Chapter 16 Test Name: Date: Directions: Write the correct letter on the blank before each question. Objective 1: Explain the way vaporization and steam relate to the extinguishing properties of water.

More information

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13 Page 1 of 13 1. Description The Viking 2 Model G-2000 Dry Valve Riser Assembly consists of a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry sprinkler

More information

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY Page 1 of 13 1. DESCRIPTION The Viking 3 Model G-3000 Dry Valve Riser Assembly is equipped with a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry

More information

INSTRUCTOR GUIDE REFERENCES: PUMPING APPARATUS DRIVER/OPERATOR HANDBOOK, FIRST EDITION, IFSTA

INSTRUCTOR GUIDE REFERENCES: PUMPING APPARATUS DRIVER/OPERATOR HANDBOOK, FIRST EDITION, IFSTA TOPIC: RELAY PUMPING OPERATIONS LEVEL OF INSTRUCTION: TIME REQUIRED: ONE HOUR INSTRUCTOR GUIDE MATERIALS: APPROPRIATE AUDIO VISUAL SUPPORT REFERENCES: PUMPING APPARATUS DRIVER/OPERATOR HANDBOOK, FIRST

More information

Colorado Division of Fire Prevention & Control Driver Operator Pumper JPRs (NFPA 1002, 2009 Edition)

Colorado Division of Fire Prevention & Control Driver Operator Pumper JPRs (NFPA 1002, 2009 Edition) Colorado Division of Fire Prevention & Control Driver Operator Pumper JPRs () JPR # Task Initial Certification JPR Requirement: 15 Mandatory Renewal JPR Requirement: 100% of All JPRs (including all subsections)

More information

PREVIEW COPY. Table of Contents. Basic Pumping Concepts...3. Maintaining Packing and Seals Lesson Three Maintaining Centrifugal Pumps...

PREVIEW COPY. Table of Contents. Basic Pumping Concepts...3. Maintaining Packing and Seals Lesson Three Maintaining Centrifugal Pumps... Table of Contents Lesson One Lesson Two Basic Pumping Concepts...3 Maintaining Packing and Seals...19 Lesson Three Maintaining Centrifugal Pumps...37 Lesson Four Overhauling Centrifugal Pumps...53 Lesson

More information

Driver Releasal Manual

Driver Releasal Manual Driver Releasal Manual In order to participate in the DPO program, the candidate must: o Possess a valid Virginia Driver s License o Be 18 years of age o Be covered under the County insurance policy o

More information

1 Exam Prep. Tabs and Highlights

1 Exam Prep. Tabs and Highlights 1 Exam Prep NFPA 14: Standard for the Installation of Standpipe and Hose Systems Tabs and s These 1 Exam Prep tabs are based on the NFPA 14: Standard for the Installation of Standpipe and Hose Systems,

More information

Chapter Overview. NFPA Standards NFPA 1001 Standard. Fire Fighter I

Chapter Overview. NFPA Standards NFPA 1001 Standard. Fire Fighter I Chapter Overview Consider a fire in a one-story, wood frame residential structure with one room fully engulfed in flames. Two engines arrive followed closely by a ladder truck. Each apparatus carries an

More information

Exercise 2-3. Flow Rate and Velocity EXERCISE OBJECTIVE C C C

Exercise 2-3. Flow Rate and Velocity EXERCISE OBJECTIVE C C C Exercise 2-3 EXERCISE OBJECTIVE C C C To describe the operation of a flow control valve; To establish the relationship between flow rate and velocity; To operate meter-in, meter-out, and bypass flow control

More information

Fire Apparatus Operator: Pumper

Fire Apparatus Operator: Pumper Fire Apparatus Operator: Pumper Skill Sheet Package Based on NFPA 1002: Standard on Fire Apparatus Driver/Operator Professional Qualifications, 2014 Edition. Alabama Fire College February 2016 revised

More information

then the work done is, if the force and the displacement are in opposite directions, then the work done is.

then the work done is, if the force and the displacement are in opposite directions, then the work done is. 1. What is the formula for work? W= x 2. What are the 8 forms of energy? 3. Write the formula for the following: Kinetic Energy Potential Energy 4. If the force and the displacement are in the same direction,

More information

TECHNICAL DATA. Page 1 of 12

TECHNICAL DATA. Page 1 of 12 Page 1 of 12 1. DESCRIPTION The Viking Regulating Valve is a direct-acting, single-seated, spring-loaded diaphragm valve. When installed as a pilot regulating valve on a Viking Model H or J Flow Control

More information

SABERINDO PACIF SABERINDO PACIFIC CIFIC SABERINDO PA. A Tyco International Company

SABERINDO PACIF SABERINDO PACIFIC CIFIC SABERINDO PA. A Tyco International Company CIF A Tyco International Company 1 Foam Concentrate CIF 3% AFFF -UL Listed -UL Canada Listed 6% AFFF 6 parts AFFF concentrate to 94 parts water -UL Listed- Foam Liquid -UL Canada Listed 3% FLUOROPROTEIN

More information

Driver Operator Pumps: Water Supplies. 2 Skills Total. NFPA 1002, Standard for Driver Operator Professional Qualifications, 2014 Edition

Driver Operator Pumps: Water Supplies. 2 Skills Total. NFPA 1002, Standard for Driver Operator Professional Qualifications, 2014 Edition Driver Operator Pumps: Water Supplies 2 Skills Total NFPA 1002, Standard for Driver Operator Professional Qualifications, 2014 Edition Driver Operator Pumps: Water Supplies Skills Book JPR NFPA 1002 Task:

More information

Master Control Systems, Inc. Variable Speed Fire Pump Controllers

Master Control Systems, Inc. Variable Speed Fire Pump Controllers Master Control Systems, Inc. Variable Speed Fire Pump Controllers Meets NFPA 20-2019 UL/FM Listed and Approved for fire protections * Pressure Limiting Control * Suction Limiting Control Why Variable Speed?

More information

Chapter 14 Water Shuttle Operations

Chapter 14 Water Shuttle Operations 1. Which of the following statements about water shuttle operations is TRUE? A. Water shuttle operations may create a dramatic hose failure B. Water shuttle operations are safer than relay pumping operations

More information

TECHNICAL DATA. Pressure Regulation 531a. April 24, 2009

TECHNICAL DATA. Pressure Regulation 531a. April 24, 2009 April 24, 29 Pressure Regulation 531a 1. DESCRIPTION The Viking Regulating Valve is a direct-acting, single-seated, spring-loaded diaphragm valve. When installed as a pilot regulating valve on a Viking

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S January 6, 2012 Preaction 331a 1. Description Viking supervised Double-Interlocked Electric/Pneumatic Release Preaction Systems utilize the Viking G-3000P Valve. The small profile, lightweight, pilot-operated

More information

Fire Apparatus Operator: Pumper

Fire Apparatus Operator: Pumper Fire Apparatus Operator: Pumper Skill Sheet Package Based on NFPA 1002: Standard on Fire Apparatus Driver/ Operator Professional Qualifications, 2017 Edition. Alabama Fire College August, 2018 revised

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S January 6, 2012 Preaction 348a 1. Description Viking supervised Surefire Preaction Systems utilize the Viking G-6000P Valve. The small profile, lightweight, pilot operated Viking G-6000P Valve comes complete

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S Preaction 346a 1. Description The 6 Model G-6000P Electric Release Preaction System Riser Assembly can be used as a Single Interlock Preaction System with Electric Release, or as a Double Interlock Preaction

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S January 6, 2012 Preaction 333a 1. Description Viking supervised Surefire Preaction Systems Utilize the Viking G-3000P Valve. The small profile, lightweight, pilot-operated Viking G-3000P Valve comes complete

More information

ENGINE 260 REVISED

ENGINE 260 REVISED ENGINE 260 REVISED - 2018-1- TABLE OF CONTENTS General Rules... 3-4 Event Rules Ladder Climb... 5 Tug-O-War... 7 Lakeside Draft Motorized... 7 Hand Pumpers... 8 Midnight Alarm... 9 Water Barrel... 10 Arena

More information

Master Control Systems, Inc. Variable Speed Fire Pump Controllers

Master Control Systems, Inc. Variable Speed Fire Pump Controllers Master Control Systems, Inc. Variable Speed Fire Pump Controllers Meets NFPA 20-2013 UL/FM Listed and Approved for fire protections 1 Why Variable Speed? Huge Sprinkler System and Standpipe Cost Savings

More information

SIZING OF WATER PIPING SYSTEM

SIZING OF WATER PIPING SYSTEM SIZING OF WATER PIPING SYSTEM (This appendix is informative and is not part of the code.) SECTION AP101 GENERAL AP101.1 Scope. AP101.1.1 This appendix outlines two procedures for sizing a water piping

More information

San Ramon Valley Fire Protection District

San Ramon Valley Fire Protection District San Ramon Valley Fire Protection District March, 2009 Company Performance Standards i Introduction This manual establishes a series of standard incident-based company evolutions for District use. Collectively,

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S January 6, 2012 Preaction 347a 1. Description Viking supervised Double-Interlocked Electric/Pneumatic Release Preaction Systems utilize the Viking G-6000P Valve. The small profile, lightweight, pilot operated

More information

DESIGN DATA. Dry 105a. September 5, 2008

DESIGN DATA. Dry 105a. September 5, 2008 September 5, 2008 Dry 105a 1. Description Dry and Preaction Systems require a dependable source of clean dry air under the proper pressure. The air supply must be adequate to restore normal air pressure

More information

NOTES ON WATER HAMMER. 55

NOTES ON WATER HAMMER. 55 NOTES ON WATER HAMMER. 55 NOTES ON WATER HAMMER. By A. B. Robison. When the flow conditions of a liquid in a pipe line are varied by the opening or closing of a valve or the equivalent, a change in the

More information

APPLYING VARIABLE SPEED PRESSURE LIMITING CONTROL DRIVER FIRE PUMPS. SEC Project No

APPLYING VARIABLE SPEED PRESSURE LIMITING CONTROL DRIVER FIRE PUMPS. SEC Project No APPLYING VARIABLE SPEED PRESSURE LIMITING CONTROL DRIVER FIRE PUMPS SEC Project No. 1803007-000 November 20, 2006 TABLE OF CONTENTS I. ABSTRACT...1 II. INTRODUCTION...1 III. HISTORY...2 IV. VARIABLE SPEED

More information

TECHNICAL DATA SINGLE INTERLOCKED PREACTION SYSTEM WITH PNEUMATIC RELEASE

TECHNICAL DATA SINGLE INTERLOCKED PREACTION SYSTEM WITH PNEUMATIC RELEASE 1 of 10 1. DESCRIPTION (Refer to Figures 1-3.) Viking supervised Single Interlocked Preaction Systems utilize a Viking Deluge Valve and a pneumatically pressurized automatic sprinkler system. The system

More information

Varying pump capacity affects the required hoseline diameter

Varying pump capacity affects the required hoseline diameter Slide 1 Rural Fire Command by Larry Davis Issue #34 October 2005 H 2 O On The Go Varying pump capacity affects the required hoseline diameter 1 Slide 2 Training America s Rural Fire & Emergency Responders

More information

Standard Operating and Maintenance Instructions for Pumping System Model PS-90

Standard Operating and Maintenance Instructions for Pumping System Model PS-90 Standard Operating and Maintenance Instructions for Pumping System Model PS-90 High Pressure Equipment Company 2955 West 17th Street, Suite 6 PO Box 8248 Erie, PA 16505 USA 814-838-2028 (phone) 814-838-6075

More information

Blue River Technologies Port-A-Poly Mixer w/2.5 GPH LMI Pump And Secondary Water Dilution Line INSTALLATION AND OPERATION

Blue River Technologies Port-A-Poly Mixer w/2.5 GPH LMI Pump And Secondary Water Dilution Line INSTALLATION AND OPERATION Blue River Technologies Port-A-Poly Mixer w/2.5 GPH LMI Pump And Secondary Water Dilution Line INSTALLATION AND OPERATION Install your Blue River Technologies Port-A-Poly mixing system in a clean dry area.

More information

Head to Head Demo Comparison Sheet

Head to Head Demo Comparison Sheet Head to Head Demo Comparison Sheet Task Force Tips Crossfire Portable/Deck Mount Monitor The purpose of this document is to encourage you to compare TFT products head to head, apples to apples, with like

More information

ESCONDIDO FIRE DEPARTMENT TRAINING MANUAL ENGINE MODULE HOSE PAGE 1 OF 24 Attack Hose Lays Revised

ESCONDIDO FIRE DEPARTMENT TRAINING MANUAL ENGINE MODULE HOSE PAGE 1 OF 24 Attack Hose Lays Revised HOSE 12-01-16 PAGE 1 OF 24 To effectively attack and extinguish a fire, hose lines must be removed from the apparatus and advanced to the location of the fire. The techniques used to advance hose lines

More information

Data Sheet Issue A

Data Sheet Issue A Features 1. Differential latching clappertype, lighweight, dependable construction. 2. Low Air Pressurized System, 8 psi -to- 26 psi (0,6 bar to- 1,8 bar) 3. Reset externally. Cover removal is not required.

More information

appendix a recommended rules For sizing the water supply system PRE-PRINT Chart a 1.2 FriCtion losses For Disk-type water Meters

appendix a recommended rules For sizing the water supply system PRE-PRINT Chart a 1.2 FriCtion losses For Disk-type water Meters recommended rules For sizing the water supply system Because of the variable conditions encountered, it is impractical to lay down definite detailed rules of procedure for determining the sizes of water

More information

APPENDIX A RECOMMENDED RULES FOR SIZING THE WATER SUPPLY SYSTEMS CHART A-1 FRICTION LOSSES FOR DISK-TYPE WATER METERS 1-1/2"

APPENDIX A RECOMMENDED RULES FOR SIZING THE WATER SUPPLY SYSTEMS CHART A-1 FRICTION LOSSES FOR DISK-TYPE WATER METERS 1-1/2 RECOMMENDED RULES FOR SIZING THE WATER SUPPLY SYSTEMS Because of the variable conditions encountered, it is impractical to lay down definite detailed rules of procedure for determining the sizes of water

More information

TECHNICAL DATA CAUTION

TECHNICAL DATA CAUTION Page 1 of 12 1. DESCRIPTION The Viking Model C-2 Pilot Pressure Regulating Valve is a direct-acting, single-seated, spring-loaded diaphragm valve. When installed as a pilot regulating valve on a Viking

More information

22. Specialty Valves.

22. Specialty Valves. 22. Specialty Valves. a. Types of Specialty Valves. 1) Use of the following specialty valves is covered in this section: Altitude Valve, Pressure Reducing Valve, Pressure Relief Valve, Swing Check Valve,

More information

Horizontal Bladder Tanks

Horizontal Bladder Tanks DATA SHEET Horizontal Bladder Tanks Features UL Listed and FM Approved for use with various ANSUL proportioners and foam concentrates 175 psi (12.1 bar) maximum allowable working pressure (design pressure)

More information

APPENDIX A RECOMMENDED RULES FOR SIZING THE WATER SUPPLY SYSTEM CHART A 1.2 FRICTION LOSSES FOR DISK-TYPE WATER METERS 1-1/2"

APPENDIX A RECOMMENDED RULES FOR SIZING THE WATER SUPPLY SYSTEM CHART A 1.2 FRICTION LOSSES FOR DISK-TYPE WATER METERS 1-1/2 RECOMMENDED RULES FOR SIZING THE WATER SUPPLY SYSTEM Because of the variable conditions encountered, it is impractical to lay down definite detailed rules of procedure for determining the sizes of water

More information

STUDENT SUPPLEMENT. Approved and Adopted by the Office of State Fire Marshal

STUDENT SUPPLEMENT. Approved and Adopted by the Office of State Fire Marshal F I R E A P P A R A T U S DRIVER/OPERATOR 1B Approved and Adopted by the Office of State Fire Marshal Recommended for adoption by the Statewide Training and Education Advisory Committee and the State Board

More information

Irrigation System Winterization and Pressurization Procedures

Irrigation System Winterization and Pressurization Procedures Irrigation System Winterization and Pressurization Procedures Introduction Any time that an irrigation system is filled and pressurized, or when the system is drained and water flushed from the system,

More information

PTF4 Pivotrol Pump (patented) version Dual Mechanism - Pressure Powered Pump

PTF4 Pivotrol Pump (patented) version Dual Mechanism - Pressure Powered Pump Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

SIZING OF WATER PIPING SYSTEM

SIZING OF WATER PIPING SYSTEM SIZING OF WATER PIPING SYSTEM The provisions contained in this appendix are not mandatory unless specifically referenced in the adopting ordinance. E101.1 Scope. SECTION E101 GENERAL E101.1.1 This appendix

More information

TECHNICAL DATA. Page 1 of 8. model f /2 (dn40) & 2 (dn50)

TECHNICAL DATA. Page 1 of 8. model f /2 (dn40) & 2 (dn50) Page 1 of 8 1. DESCRIPTION The Viking Model F-1 Deluge Valve is a quick opening, differential diaphragm, flood valve with one moving mechanism. The Deluge Valve is used to control water flow in Deluge

More information

A centrifugal pump consists of an impeller attached to and rotating with the shaft and a casing that encloses the impeller.

A centrifugal pump consists of an impeller attached to and rotating with the shaft and a casing that encloses the impeller. Centrifugal pump How centrifugal pumps work A centrifugal pump consists of an impeller attached to and rotating with the shaft and a casing that encloses the impeller. In centrifugal pump, liquid is forced

More information

TECHNICAL DATA OBSOLETE

TECHNICAL DATA OBSOLETE April 9, 2009 Preaction 326a 1. DESCRIPTION Viking supervised Double-Interlocked Electric/Pneumatic Release Preaction Systems utilizing the Viking G-4000P Deluge Valve. The small profi le, lightweight,

More information

Model DDX-LP Dry Pipe Valve System 8 (200mm) Features. Differential latching clapper-type, lighweight, dependable construction.

Model DDX-LP Dry Pipe Valve System 8 (200mm) Features. Differential latching clapper-type, lighweight, dependable construction. Bulletin 335 Model DDX-LP Dry Pipe Valve System 8 (200mm) Bulletin 335 Features 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. Differential latching clapper-type, lighweight, dependable construction. Low Air Pressurized

More information

KILGORE FIRE DEPARTMENT

KILGORE FIRE DEPARTMENT Page 1 of 13 KILGORE FIRE DEPARTMENT Operations/ SOP Directive Issue Date: 01/01/2013 237 Effective: 01/01/2013 COMPANY PERFORMANCE STANDARDS 237.1 Purpose The purpose of this procedure is to define and

More information

NGP-250/500 Nitrogen Generator Quick Start Guide

NGP-250/500 Nitrogen Generator Quick Start Guide NGP-250/500 Nitrogen Generator Quick Start Guide Version: A July 2013 Potter Electric Signal Company, LLC 5757 Phantom Dr., Suite 125 P. O. Box 42037 Hazelwood, MO 63042 Phone: (314) 595-6900 Document

More information

TECHNICAL DATA PILOT PRESSURE REGULATED DELUGE SYSTEM CONTROLLED BY PNEUMATIC RELEASE. 1. DESCRIPTION (Refer to Figures 1, 2 or 3.

TECHNICAL DATA PILOT PRESSURE REGULATED DELUGE SYSTEM CONTROLLED BY PNEUMATIC RELEASE. 1. DESCRIPTION (Refer to Figures 1, 2 or 3. Page 1 of 8 1. DESCRIPTION A Viking Pilot Pressure Regulated Deluge System utilizes a Viking Flow Control Valve to control water flow into the deluge system. The flow control valve must be installed with

More information

Poudre Fire Authority Driver/Operator Manual Third Edition March 2006

Poudre Fire Authority Driver/Operator Manual Third Edition March 2006 Poudre Fire Authority Driver/Operator Manual Third Edition March 2006 Copyright 2006 Poudre Fire Authority Fort Collins, Colorado http://www.poudre-fire.org Introduction ii Introduction Table of Contents

More information

PRESSURE ADJUSTMENT Main pressure adjustment

PRESSURE ADJUSTMENT Main pressure adjustment 8001-38 PRESSURE ADJUSTMENT Main pressure adjustment Adjustment preparation work Pressure is adjusted with control valves. The following preparations are required for adjusting with control valves. 1.

More information

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B September 16, 2013 Trimpac 250a 1. DESCRIPTION DEsCRIPTIoN is a factory assembled trim package for a ed an electric/pneumatic release module in a metal enclosure. The standard trim normally required on

More information

Pipe Thread Connection 1/2 inch NPT. Friction Loss Refer to Figure 3

Pipe Thread Connection 1/2 inch NPT. Friction Loss Refer to Figure 3 Worldwide Contacts www.tyco-fire.com Model B-1 Pipe Line Strainer General Description The Model B-1 Pipe Line Strainers (Ref. Figures 1 and 2) are designed for installation in the water supply connection

More information

Vertical Bladder Tanks

Vertical Bladder Tanks DATA SHEET Vertical Bladder Tanks Features UL Listed and FM Approved for use with various ANSUL proportioners and foam concentrates 175 psi (12.1 bar) maximum allowable working pressure (design pressure)

More information

SINGLE VALVE WITH LOW-FLOW BYPASS

SINGLE VALVE WITH LOW-FLOW BYPASS CONTROL VALVES Pressure Reducing Valve Sizing Guide Sizing pilot operated reducing valves is not a complicated process. It starts with determining requirements and following these guidelines in valve size

More information

KJ4000 Operating Instructions & Parts Manual NSN

KJ4000 Operating Instructions & Parts Manual NSN KJ4000 Operating Instructions & Parts Manual NSN 1025-01-473-7710 Mandus Group Ltd. KJ4000 Operators Manual Date: 3 Jan. 2002 TABLE OF CONTENTS General Safety Instructions...Page 1 Operator Instructions...Page

More information

INSTRUCT-O-GPAM THE HANDS-ON TRAINING GUIDE FOR THE FIRE INSTRUCTOR FIRE HOSE AND NOZZLES

INSTRUCT-O-GPAM THE HANDS-ON TRAINING GUIDE FOR THE FIRE INSTRUCTOR FIRE HOSE AND NOZZLES INSTRUCT-O-GPAM THE HANDS-ON TRAINING GUIDE FOR THE FIRE INSTRUCTOR VOLUME XIV, ISSUE 1 FIRE HOSE AND NOZZLES JANUARY 1993 FIRE HOSE AND NOZZLES This is a two-part lesson covering Fire Hose and Nozzles.

More information

Air Eliminators and Combination Air Eliminators Strainers

Air Eliminators and Combination Air Eliminators Strainers Description Air Eliminators and Combination Air Eliminator Strainers are designed to provide separation, elimination and prevention of air in piping systems for a variety of installations and conditions.

More information

DW Module 8: Distribution Answer Key

DW Module 8: Distribution Answer Key DW Module 8: Distribution Answer Key Unit 1: Unit 1 Exercise 1. To become certified in distribution systems, a person must: a. Successfully complete the Water Class E Distribution System certification

More information

Pumping Systems for Landscaping Pumps, Controls and Accessories. Mark Snyder, PE

Pumping Systems for Landscaping Pumps, Controls and Accessories. Mark Snyder, PE October 21, 2010 Pumping Systems for Landscaping Pumps, Controls and Accessories Mark Snyder, PE Pump Station Design Purpose of Pump Stations Pump stations are designed to boost water pressure from a lower

More information

FOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM

FOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM IMI CORNELIUS INC One Cornelius Place Anoka, MN 55303-623 Telephone (800) 238-3600 Facsimile (612) 22-326 INSTALLATION INSTRUCTIONS FOR INSTALLING CO 2 BLENDER KIT (P/N 111612000 IN BEER SYSTEM SECONDARY

More information

FIRE FIGHTER II SKILL PERFORMANCE CHECK SHEETS NFPA FIRE FIGHTER II SKILL STATION MENU

FIRE FIGHTER II SKILL PERFORMANCE CHECK SHEETS NFPA FIRE FIGHTER II SKILL STATION MENU FIRE FIGHTER II SKILL STATION MENU STATION TASK(S) A FIREGROUND OPERATIONS/FIRE COMMUNICATIONS MANDATORY B SPRINKLER DRAIN/PRESSURES RANDOM C PITOT GAUGE USE RANDOM D INSPECTION/MAINTENANCE: GENERATOR,

More information

MATH AND MAINTENANCE FOR PUMPS AND BLOWERS TRAINING SEMINAR

MATH AND MAINTENANCE FOR PUMPS AND BLOWERS TRAINING SEMINAR MATH AND MAINTENANCE FOR PUMPS AND BLOWERS TRAINING SEMINAR FORCE WEIGHT OF WATER MEASURED IN POUNDS PRESSURE = FORCE PER UNIT AREA WEIGHT PER UNIT AREA PRESSURE (PSI) = FORCE (LBS) / AREA (IN 2 ) P (PSI)

More information

TECHNICAL DATA. Trimpac 244a. September 16, 2013

TECHNICAL DATA. Trimpac 244a. September 16, 2013 September 16, 2013 Trimpac 244a 1. DEsCrIpTION DESCRIPTION TRIMPAC Model B-1 and B-1B is a factory-assembled trim package with an electric release module in a metal enclosure. The standard trim normally

More information

FM Approved - Automatic Water Control Valve as standard deluge valve. No formal approval available for coating. Foam Concentrate

FM Approved - Automatic Water Control Valve as standard deluge valve. No formal approval available for coating. Foam Concentrate December 6, 2010 Foam 31a 1. Description With Multiple Pilot Pressure Regulating Foam/Water Deluge Systems Supplied by a Bladder Tank, multiple pilot pressure regulating foam risers can be supplied from

More information

TECHNICAL DATA. Trimpac 251a. Spetember 16, 2013

TECHNICAL DATA. Trimpac 251a. Spetember 16, 2013 Spetember 16, 2013 Trimpac 251a 1. DEsCrIpTION DESCRIPTION TRIMPAC Model B-6 and B-6B is a factory assembled trim package for a double interlocked preaction system with an electric/pneu-lectric release

More information

TECHNICAL DATA PILOT PRESSURE REGULATED DELUGE SYSTEM CONTROLLED BY ELECTRIC RELEASE 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3.

TECHNICAL DATA PILOT PRESSURE REGULATED DELUGE SYSTEM CONTROLLED BY ELECTRIC RELEASE 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3. Page 1 of 8 1. DESCRIPTION A Viking Pilot Pressure Regulated Deluge System utilizes a Viking flow control valve to control water flow into the deluge system. The flow control valve must be installed with

More information

LAKOS Waterworks. PWC Series Sand Separators. Installation & Operation Manual LS-829 (10/12)

LAKOS Waterworks. PWC Series Sand Separators. Installation & Operation Manual LS-829 (10/12) LAKOS Waterworks PWC Series Sand Separators Installation & Operation Manual LS-829 (10/12) Table of Contents Separator Operation... 3 Individual Model Details.... 4 Flow vs. Pressure Loss Chart 4 Installation

More information

FIRE FIGHTER II - SKILLS PERFORMANCE SHEET

FIRE FIGHTER II - SKILLS PERFORMANCE SHEET Fire Fighter II Skill Stations: NFPA 1001 2013 Edition Station A Fire Ground Communications & Operations / Interior Attack Coordination MANDATORY STATION Station B Sprinkler Drain/Pressures RANDOM STATION

More information

Model MTB-ASME Horizontal Bladder Tanks

Model MTB-ASME Horizontal Bladder Tanks DATA SHEET Model MTB-ASME Horizontal Bladder Tanks Features n UL Listed and FM Approved for use with various proportioners and foam concentrates n 175 psi (12.1 bar) maximum allowable working pressure

More information

Features. Model DDX-LP Dry Pipe Valve System 4 (100mm), 6 (150mm) & 165mm Sizes

Features. Model DDX-LP Dry Pipe Valve System 4 (100mm), 6 (150mm) & 165mm Sizes Bulletin 357 Rev. E Model DDX-LP Dry Pipe Valve System 4 (100mm), 6 (150mm) & 165mm Sizes Bulletin 357 Rev. E Features 1. 2. 3. 4. 5. 6. 7. 8. 9. Differential-type valve, lightweight, dependable construction.

More information

The Discussion of this exercise covers the following points: Pumps Basic operation of a liquid pump Types of liquid pumps The centrifugal pump.

The Discussion of this exercise covers the following points: Pumps Basic operation of a liquid pump Types of liquid pumps The centrifugal pump. Exercise 2-3 Centrifugal Pumps EXERCISE OBJECTIVE In this exercise, you will become familiar with the operation of a centrifugal pump and read its performance chart. You will also observe the effect that

More information

Wet pipe low flow foam/water system

Wet pipe low flow foam/water system December 6, 2010 Foam 14a 1. The Viking Low Flow Foam/Water proportioning system, is a UL Listed and FM Approved system, for use with Viking supplied foam concentrates. This system consists of a standard

More information

Dean Pump Self-Priming Chemical Process Pumps

Dean Pump Self-Priming Chemical Process Pumps Bulletin C 1.2.34.7 Dean Pump Self-Priming Chemical Process Pumps php Series HEAD CAPACITY RANGE CHARTS php Self Primer - 2 Pole 3500 RPM 500 CAPACITY M 3 /HR 2900 RPM 50 HERTZ 25 50 75 125 150 400 TOTAL

More information

UBEC 1AT. AUTO TANK Fill System Installation, Operation, & Setup Instructions

UBEC 1AT. AUTO TANK Fill System Installation, Operation, & Setup Instructions Document Number: XE-ATA5PM-R1A UBEC 1AT AUTO TANK Fill System 08899155 Installation, Operation, & Setup Instructions Rev170906-EB-FRC PHYSICAL: 1302 WEST BEARDSLEY AVE ELKHART, IN 46514 WWW.ELKHARTBRASS.COM

More information

PumpAgents.com - Click here for Pricing/Ordering Nominal psi (bar) Cut-In Cut-Out

PumpAgents.com - Click here for Pricing/Ordering Nominal psi (bar) Cut-In Cut-Out PumpAgents.com - Click here for Pricing/Ordering Model 31670-Series Dual Max 7.5 GPM (28 LPM) AUTOMATIC TWO STAGE WATER SYSTEM WITH ACCUMULATOR TANK AND PUMPGARD STRAINER IDEAL FOR PLEASURE AND COMMERCIAL

More information

Pump Stages. By Tom Murray

Pump Stages. By Tom Murray Pump Stages By Tom Murray As is often the case, we in the fire service tend to make things more difficult than they need to be. I believe this is the situation when discussing the pros and cons of single,

More information

Tentec. Instruction Document. Mini Air Driven Pump Unit Model: HTT.627X Series. Part Identifier

Tentec. Instruction Document. Mini Air Driven Pump Unit Model: HTT.627X Series. Part Identifier Tentec Page 1 w w w. t e n t e c. n e t Instruction Document Mini Air Driven Pump Unit Model: HTT.627X Series HTT.6271 Maximum Working Pressure = 1500bar (21750 psi) HTT.6272 Maximum Working Pressure =

More information

Operating Instructions

Operating Instructions Operating Instructions Before operating the thin film evaporator, please be aware of all safety concerns associated with this experiment: Burn hazard from the column and steam lines, Chemical hazards associated

More information