xendos 1800 Oxygen Analyser The xendos 1800 is a stable, accurate and highly specific oxygen analyser for safe areas.

Size: px
Start display at page:

Download "xendos 1800 Oxygen Analyser The xendos 1800 is a stable, accurate and highly specific oxygen analyser for safe areas."

Transcription

1 xendos 1800 Oxygen Analyser The xendos 1800 is a stable, accurate and highly specific oxygen analyser for safe areas. Designed for safe area oxygen analysis Low maintenance and re-calibration requirements Range of alarm outputs to aid integration with other systems Easy to set up and operate Special versions for solvent bearing samples Special high flow rate cell option Specification Gases Measured: O 2 PERFORMANCE Technology: Paramagnetic transducer Range: 0-100% O 2 Intrinsic Error (accuracy): <0.2% of reading or 0.05% O 1 2 Linearity: <0.05% O 2 2 Repeatability: <0.1% of reading or 0.05% O 1 2 Response time (T 90 ) 4 to 8 seconds 3 Zero drift/ week: Span drift/ week: <0.05% O 2 <1% of reading or 0.05% O 1 2 SIGNAL OUTPUTS Analogue: One 4-20 ma, isolated & one 0-1V dc, non-isolated. Ranges selectable from 0-2.5, 5, 10, 25 and 100% O 2 Alarms: Concentration Two volt free changeover relays rated 250Vac/3A or 28Vdc (non inductive) maximum and 5V/10mA ac/dc minimum Sample flow fail One volt free changeover relay rated 250Vac/3A or 28Vdc (non inductive) maximum and 5V/10mA ac/dc minimum PHYSICAL Dimensions:(W x D x H) 448mm x 229mm x 235 mm / 17.6 x 9 x 9.25 Weight: 26 kg / 57 lbs Hazardous area Classification: Non-Hazardous Areas only Ingress Protection: IP 66 / NEMA 4X Mounting: Wall or Panel 1 whichever is the greater 2 inherently linear, value dependant on calibration gases 3 dependant on configuration LEADERS IN GAS ANALYSIS

2 Ambient Conditions Temperature: Operating: -10 C to 50 C/14 F to 122 F Storage: -20 C to 55 C/-4 F to 131 F Atmospheric Pressure: 79 to 124 kpaa/11 to 18psia (for operation up to 2000m altitude.) Warm Up Time 4 hours at an ambient temperature of 20 C (68 F) Power Supply 100 to 240V ac ±10% - 50/60Hz -50VA max. Note: The internal pumps are AC voltage dependant and are supplied as 110Vac 50, 110Vac 60Hz, or 230Vac 50Hz. Ensure that the correct AC input voltage is supplied to an analyser fitted with a sample pump. Sample Wetted Materials Material Of Construction Basic Analyser Standard Cell + Flow Alarm Standard Cell + AFCD Standard Cell + Sample Pump Standard Cell + BPR High Flow rate cell / Stainless Steel Pipework Solvent Reistant Cell + Stainless Steel Pipework Solvent Resistant Cell +Hastelloy pipework Beryllium-Copper Borosilicate Glass Bonded Borosilicate Glass Fibre Brass Phospher Bronze Fluorocarbon Rubber Hastelloy C-276 Nickel (electroless) Neoprene Rubber Glass Filled Nylon 12 Polysulphone Platinum Platinum / Iridium alloy Glass Filled Polypropylene Polypropylene PVC PVDF Gold Plated Silver 302 / EN58A SSteel 303 Stainless Steel 316 Stainless Steel Viton (325 cell) Viton - A Chemraz (364 cell) PTFE Sample Gas Conditions Basic with with with S.Steel or Configuration Analyser AFCD AFCD and AFCD and Hastelloy/PFA Sample Pump BPR High Flow cell or bypass Inlet Pressure 0.04 psig/ 1 to 5 psig/ to 1 psig/ 17 to 22 psia/ 0.05 psig/ 0.3 kpag minimum 7 to 35 kpag -0.2 to 7kPag 119 to 154 kpaa 0.4 kpag minimum Flow Rate 50 to 250ml/min 1.2 to 3.5 l/min 1.6 to 1.8 l/min 1.0 to 2.0 l/min 50 to 70 l/hour (60 l/hour nominal) Vent Pressure 11.5 to 18.0 psia (80.5 to 126kPaa) - DO NOT RESTRICT ANALYSER VENT Dew Point Non-condensing at ambient temperature Temperature -10 C to +50 C (+14 F to +122 F) Particulates <3µm (micron) Condition Clean, non-flammable * and free from oil/condensate** Connections ¼ NPT. INT Inlet/Outlet Connectors (Female). (6mm option available) Adjust pressure and sample flow externally to provide sample flow rate * For Flammable samples use the xendos 1900 ** For Corrosive samples use a solvent resistant cell option AFCD - Automatic Flow Control Device BPR - Back Pressure Regulator Front View 448mm / 17.6 Side View 229mm / 9 407mm / mm / mm / 9.25

3 Analyser The xendos 1800 is fitted as standard with the following features: Analogue outputs: Isolated 4-20mA, 600 ohm maximum impedance, non-isolated 0-1V d.c. minimum impedance 470 ohms. The analogue output signals can be set to one of two pre-selectable measurement ranges. Concentration Alarms: Two volt free changeover relay outputs and LED. User configurable as high or low, set point field adjustable over the range 0-100%O 2 Range Indication: Volt free changeover relay outputs and LED Please note: this analyser is not suitable for use with flammable samples, use the xendos 1900 Sample Conditioning Options The xendos 1800 is available with a number of sampling options, to suit a variety of applications. Your choice will affect both sample wetted materials, and the required sample condition. Where the sample is non-corrosive choose from the columns headed: Standard Cell. Choose Automatic Flow Control Device (AFCD) c/w internal sample filter to simplify sample flow control. Choose Automatic Flow Control Device (AFCD) and Back Pressure Regulator (BPR) to reduce the effects of changes in barometric or vent pressure when measuring high concentrations of oxygen. Choose the sample flow fail alarm option to provide a volt free changeover relay output and LED indication when the flow falls below the minimum required level (during a Sample Flow fail condition, the analogue output can be pre-configured to be driven high (>20mA), or low (<4mA, default). Choose a sample pump if the sample supplied to the analyser is at an insufficient pressure to generate a suitable flow rate. Where enhanced pipework integrity is required, or where the sample is corrosive or solvent bearing, or where a high sample flow rate is required, choose from the column headed Special Cell & Metal Pipework. Display The xendos 1800 is available with either a 3 1 /2 digit display, capable of displaying Sample Inlet Sample Inlet fittings can be supplied as: Enclosure Fittings Three options are available, the choice depends on application. None: sealed enclosure. 00.0% to 100.0% O2, or a 4 1 /2 digit display capable of displaying 00.00% to 1 /4 NPTF 316 stainless steel fittings, 6mm OD 316 stainless steel fittings, 6mm OD Hastelloy fittings Purge fittings: 1 /4 NPTF Inlet/Outlet connectors can be fitted to the sample compartment of the enclosure to provide protection against internal toxic and/or corrosive sample gas leaks % O2 Breather port: A Breather Port with a 1 /4 NPT connector can be fitted to the sample compartment of the enclosure to provide pressure relief protection resulting from internal sample gas leaks. Conduit Entry The xendos 1800 is supplied with a choice of cable entry. Choose from: Mounting The xendos 1800 is available for either wall or panel mounting. Quickstart Manual The xendos 1800 is supplied with a Quickstart TM manual in a variety of languages. 3 /4 NPT conduit entry M20 Pg13.5 The flush panel mounting analyser is supplied with a panel cutout and additional mounting brackets. Service Manual A service manual containing technical descriptions, fault diagnosis information, parts removal, refitting and test instructions, tool and test equipment lists, and electrical drawings is available. It is intended for use by Servomex trained service personnel.

4 Analyser xendos 1800 Analyser (01800B1GEN) Enquiry & Ordering Information To Specify the analyser you require, enter your details below, tick one option in each box and post or fax to your local Servomex company, agent, or representative. Name: Company: Address: Order/Enquiry Number Please send me details of planned maintenance services & recommended spares Standard Cell, (Viton Pipework) Basic Analyser (01) with flow alarm (03) with AFCD (04) with AFCD & BPR (05) with flow alarm & AFCD (06) with flow alarm, AFCD & BPR (07) Standard Cell, (Viton Pipework with Pump) with AFCD & Pump (110V/50Hz) (08) with AFCD & Pump (110V/60Hz) (09) with AFCD & Pump (230V/50Hz) (10) with AFCD, flow alarm & Pump (110V/50Hz) (11) with AFCD, flow alarm & Pump (110V/60Hz) (12) with AFCD, flow alarm & Pump (230V/50Hz) (13) 1 Special Cell & Metal Pipework Standard cell, stainless steel pipework (02) Solvent resistant cell, stainless steel pipework (14) Solvent resistant cell, with Hastelloy pipework (15) High flow rate cell, stainless steel pipework (16) High flow rate, solvent resistant cell, stainless steel pipework (17) High flow rate solvent resistant cell, Hastelloy pipework (18) Standard cell, stainless steel bypass (19) Solvent resistant cell, stainless steel bypass (20) Solvent resistant cell, Hastelloy bypass (21) Display /2 digits (001) 4 1 /2 digits (002) Sample Inlet 4 1 /4 NPT (0) 6mm OD stainless steel (1) 6mm OD Hastelloy (2) Enclosure 5 None (0) Purge Fittings (1) Breather port (2) Conduit Entry 6 3 /4 NPT (1) M20 (2) PG 13.5 (3) Mounting 7 Wall mounted (0) Flush panel mounted (1) Quickstart Manual 8 English (1) French (2) German (3) Spanish (4) Portuguese (5) Dutch (6) Italian (7) Japanese (8) Chinese (9) Service Manual 9 None (0) Service manual (English) (1) LEADERS IN GAS ANALYSIS

5 Performance Approval The xendos 1800 complies with EN50104:1999 Electrical apparatus for the detection and measurement of oxygen. EC Directive Compliance The xendos 1800 complies with the Low Voltage Directive 73/23/EEC and the EMC Directive 89/336/EEC (as amended by Directive 92/31/EEC), both as amended by Directive 93/68/EEC. It conforms to the following harmonised European standards for product safety and electromagnetic compatibility: EN : Generic emission standard EN : Generic immunity standard EN : Safety requirements for electrical equipment for measurement, control and laboratory use. This product is rated for Installation Category II in accordance with IEC 664. This product is rated for Pollution Degree 2 in accordance with IEC 664. Performance Specification Continued Configuration Units Base with with AFCD with AFCD High Flow Transducers, Analyser AFCD and Sample Pump and BPR Standard or Solvent resistant Response time (T 90 ) Seconds <4 <7 <8 <7.5 <5 (200ml/min) (60 l/hour) Noise (peak to peak) %O 2 <0.04 <0.05 <0.05 <0.04 <0.04 Ambient Pressure % of reading for a 1% < Coefficient change in ambient pressure Sample Flow Rate % O 2 over 50 to <0.1 N/A N/A N/A <0.2 Effect 250ml/min (over 50 to 70 liters/hour) Ambient Temperature Coefficient /10 C 0.2 % O 2 ±0.5% of reading The performance specification has been written, and verified, in accordance with the international standard IEC :1994 Expression of performance of gas analysers.

6 Servomex companies, agents and representatives are located throughout the world. Your nearest contact is: Visit for technical data sheets, application and technology information for all Servomex analysers. Servomex has a policy of constant product improvement and therefore reserves the right to change specifications without notice. Certificate No. Q05166 BS EN ISO 9001 LEADERS IN GAS ANALYSIS Servomex Group Limited, Jarvis Brook, Crowborough, East Sussex, TN6 3DU, England (44) Fax: (44) Servomex B.V., Stephensonstraat 20, 2723 RN Zoetermeer, Netherlands (31) Fax: (31) Servomex S.A., 8 Rue Proudhon, B.P. 50, St Denis La Plaine Cedex, France (33) Fax: (33) Servomex GmbH, Münsterstraße 5, Hamm, Germany (49) Fax: (49) Servomex Company, Inc., 90 Kerry Place, Norwood, MA 02062, USA (1) Fax: (1) Servomex Asia Pacific Ltd, 3F-1, No.88, Sec. 6, Chung Shan N. Rd., Taipei, Taiwan (886) Fax: (886) Servomex Asia Pacific Ltd, (Spectris Group China Ltd-Shanghai Representative Office) Room 1805 Central Plaza,227 North Huang Pi Rd,Shanghai , PR China (86) Fax: (86) Global info@servomex.com Website: Servomex Group Limited A Spectris.company. All rights reserved. TDS 1800 Rev. 1 09/01 E

SERVOTOUGH Oxy (1900)

SERVOTOUGH Oxy (1900) PROCESS ANALYSERS SERVOTOUGH (1900) The SERVOTOUGH offers reliability, flexibility, simplicity of use and installation for applications in the most hazardous and challenging of environments. The worlds

More information

Plasma. Argon Production Helium Liquefaction Truck Loading Pure Gas Bottling

Plasma. Argon Production Helium Liquefaction Truck Loading Pure Gas Bottling SERVOPRO Plasma The SERVOPRO Plasma is a Plasma Emission Detector based analyser designed to continuously measure Nitrogen in pure Argon for process and quality control in Argon production within Cryogenic

More information

DF-310E PROCESS ANALYSERS APPLICATIONS FEATURES

DF-310E PROCESS ANALYSERS APPLICATIONS FEATURES PROCESS ANALYSERS DF-310E The DF-310E is a Coulometric sensor based oxygen analyzer designed to measure trace and percent level oxygen in pure and multi-gas backgrounds for process and quality control

More information

DF-550E PROCESS ANALYSERS APPLICATIONS FEATURES

DF-550E PROCESS ANALYSERS APPLICATIONS FEATURES PROCESS ANALYSERS DF-550E The DF-550E Nano Trace oxygen analyser is a Coulometric sensor based analyser designed to measure oxygen as a contaminant at ultra trace levels in ultra high purity electronic

More information

PROCESS ANALYSERS. SERVOTOUGH OxyExact (2223) Oxygen Transmitter. Installation Manual. Revision:

PROCESS ANALYSERS. SERVOTOUGH OxyExact (2223) Oxygen Transmitter. Installation Manual. Revision: PROCESS ANALYSERS SERVOTOUGH OxyExact (2223) Oxygen Transmitter Installation Manual Part Number: Revision: Language: 02223/005A 10 UK English This page intentionally blank TABLE OF CONTENTS SERVOTOUGH

More information

User and Installation Manual

User and Installation Manual COMBUSTION ANALYSERS SERVOTOUGH Fluegas(2700) 2730C Utilities Unit User and Installation Manual Part Number: 02730001C Revision: 1 Language: UK English This page intentionally blank CONTENTS LIST CONTENTS

More information

Best Practice Guide, Servomex 2700

Best Practice Guide, Servomex 2700 For full installations details refer to the. Best Practice Guide, Servomex 2700 Mounting: General Guidelines: Servomex 2700 Control Units and air supplies (utilities units) should, ideally, be mounted

More information

Level transmitter LT 100

Level transmitter LT 100 KROHNE 09/2001 7.02363.21.00 GR/PRINTO Level transmitter LT 100 Status: 10/99 Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters

More information

Precision pressure sensor Basic version Model CPT6020

Precision pressure sensor Basic version Model CPT6020 Calibration Precision pressure sensor Basic version Model CPT6020 WIKA data sheet CT 25.13 Applications Calibration technology High-accuracy pressure monitoring Pressure sensing in critical applications

More information

FLAMMABLE GAS SENSOR/TRANSMITTER

FLAMMABLE GAS SENSOR/TRANSMITTER FLAMMABLE GAS SENSOR/TRANSMITTER Plant safety protection for flammable gases. F E A T U R E S Fixed gas monitoring for point source hazards and perimeter protection in arduous duty and exposed locations.

More information

XMO2. Panametrics Smart Oxygen Analyzer. Applications. Features. bhge.com. An oxygen transmitter for use in:

XMO2. Panametrics Smart Oxygen Analyzer. Applications. Features. bhge.com. An oxygen transmitter for use in: XMO2 Panametrics Smart Oxygen Analyzer Applications An oxygen transmitter for use in: Inerting/blanketing liquid storage tanks Reactor feed gases Centrifuge gases Catalyst regeneration Solvent recovery

More information

Model PDT Dewpoint Transmitter

Model PDT Dewpoint Transmitter Model PDT Dewpoint Transmitter Instruction Manual Alpha Moisture Systems Alpha House 96 City Road Bradford BD8 8ES England Tel: +44 1274 733100 Fax: +44 1274 733200 email: mail@amsytems.co.uk web: www.amsystems.co.uk

More information

I/P Transducer Positioner Module

I/P Transducer Positioner Module I/P Transducer Positioner Module VRC P/N: 7958032 Installation, Operation and Maintenance Instructions 2.09 [53.1] 1.30 [32.9] 2.97 [75.5] 0.78 [19.8] 0.18 [4.4] 1.42 [36.1] n.18 MOUNTING HOLES (2) PLACES

More information

INSTALLATION & MAINTENANCE INSTRUCTIONS

INSTALLATION & MAINTENANCE INSTRUCTIONS DESCRIPTION / IDENTIFICATION The QBX series valve uses Proportion-Air closed loop technology for Pressure control. It gives an output pressure proportional to an electrical command signal input. The QB1X

More information

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure Z series for gage pressure Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and electronics plate Process connection Electrical connection

More information

Design Features. General Description

Design Features. General Description Model thermal Mass Flow Controllers are designed to indicate and control set flow rates of gases. The combines the characteristics and accuracy of conventional mass flow devices into a unique compact design

More information

INSTALLATION & MAINTENANCE INSTRUCTIONS DESCRIPTION SPECIFICATIONS. CE (EMC) Compliant

INSTALLATION & MAINTENANCE INSTRUCTIONS DESCRIPTION SPECIFICATIONS. CE (EMC) Compliant INSTALLATION & MAINTENANCE INSTRUCTIONS DESCRIPTION The QB3 is a closed loop pressure regulator consisting of two solenoid valves, internal pressure transducer, and electronic controls mounted to an integrated

More information

UNIK 5600/5700 Marine Certified Pressure Sensing Platform

UNIK 5600/5700 Marine Certified Pressure Sensing Platform GE Measurement & Control UNIK 5600/5700 Marine Certified Pressure Sensing Platform The new UNIK 5600/5700 carries marine certification for most zones on-board ship, as well as Intrinsically Safe certifications.

More information

Type N-10, N-11 Hazardous Area Non-incendive Transmitters

Type N-10, N-11 Hazardous Area Non-incendive Transmitters Electronic Pressure Catalog > Hazardous Area > N-10, N-11 Type N-10, N-11 Hazardous Area Non-incendive Transmitters Applications Natural gas compressors Wellhead monitoring Pipeline pressure General industrial

More information

SITRANS P measuring instruments for pressure

SITRANS P measuring instruments for pressure SITRANS P measuring instruments for pressure Z series for gage pressure Siemens AG 008 Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and

More information

Additel 761 Automated Pressure Calibrators Selection Guide

Additel 761 Automated Pressure Calibrators Selection Guide / Process Calibration Equipment Automated Calibrators Selection Guide Model Features Range Module 1 761-LLP 761-D 761-L 761-LA 761-M 761-MA 761-H 761-HA 761-BP -2.5 to 2.5 mbar (-1 to 1 inh 2 O) -0.95

More information

Additel 761 Automated Pressure Calibrators Selection Guide

Additel 761 Automated Pressure Calibrators Selection Guide Automated Calibrators Selection Guide Model Features Range 761-LLP 761-D 761-L 761-LA 761-M 761-MA 761-H 761-HA 761-BP 0.05 to 8 bar.a -0.90 to 25 bar (1.2 to 115 psi.a) (-13 to 375 psi) 0.1 to 26 bar.a

More information

Gas density monitor With integrated transmitter Model GDM-100-TI

Gas density monitor With integrated transmitter Model GDM-100-TI SF 6 gas solutions Gas density monitor With integrated transmitter Model GDM-100-TI grid Products WIKA data sheet SP 60.05 for further approvals see page 5 Applications Gas density monitoring of closed

More information

Additel 761 Automated Pressure Calibrators

Additel 761 Automated Pressure Calibrators Additel 761 Fully automated pressure calibrator with built-in pressure generator / controller to as high as 600 psi (40 bar) or as low as 0.01 Pa (0.00004 inh 2 O) accuracy Dual pressure modules Built-in

More information

Autocalibration Systems For In Situ Oxygen Analyzers

Autocalibration Systems For In Situ Oxygen Analyzers Product Data Sheet PDS 106-340AC SPS 4000, IMPS 4000, and MPS 3000 January, 1999 Autocalibration Systems For In Situ Oxygen Analyzers Cost-effective autocalibration systems for installations ranging from

More information

Miniature flowmeters DK 46, DKR 46 DK 47, DK 48, DK 800

Miniature flowmeters DK 46, DKR 46 DK 47, DK 48, DK 800 KROHNE 1/22 7.236.22. GR Miniature flowmeters DK 46, DKR 46 DK 47, DK 48, DK 8 Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters

More information

9700 Transmitter Submersible hydrostatic level transmitter

9700 Transmitter Submersible hydrostatic level transmitter Specification sheet IP0078 October 2007 Level 9700 Transmitter Submersible hydrostatic level transmitter Description The 9700 series hydrostatic level transmitter is designed to perform in the most arduous

More information

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring. Product Data Sheet CODEL Continuous Emission Monitoring GCEM4100 Extractive Gas Analyser CO, CO2, NO, NO2, SO2, HCL, CH4 & H2O Hot extractive multi-channel gas analyser for continuous process and emissions

More information

P9000 DESCRIPTION. For parts requiring RoHS compliance, please contact factory. P February /6

P9000 DESCRIPTION. For parts requiring RoHS compliance, please contact factory. P February /6 P9000 High accuracy through digital compensation High thermal stability Rugged stainless steel construction Ideal for test stands High burst pressure limit DESCRIPTION The P9000 Series is a range of advanced,

More information

Autocalibration Systems for In Situ Oxygen Analyzers

Autocalibration Systems for In Situ Oxygen Analyzers Product Data Sheet PDS 106-340AC.A01 February, 2006 SPS 4001B, IMPS 4000 and MPS 3000 Autocalibration Systems for In Situ Oxygen Analyzers Cost-effective autocalibration systems for installations ranging

More information

Rigel 601 CHECKBOX. Instruction Manual. 348A551 Issue 2.0. April Seaward Electronic Ltd. Issue 2.0

Rigel 601 CHECKBOX. Instruction Manual. 348A551 Issue 2.0. April Seaward Electronic Ltd. Issue 2.0 Rigel 601 CHECKBOX Instruction Manual 348A551 Issue 2.0 April 2006 2006 Seaward Electronic Ltd. Issue 2.0 Limited Warranty & Limitation of Liability Rigel Medical guarantees this product for a period of

More information

DPI 610/615 Series. Druck Portable. Pressure Calibrators. GE Sensing. Features. Setting the Standard for Portable. Pressure Calibrators

DPI 610/615 Series. Druck Portable. Pressure Calibrators. GE Sensing. Features. Setting the Standard for Portable. Pressure Calibrators Features Ranges -14.7 to 10,000 psi Accuracy from 0.025% full scale (FS) Integral combined pressure/vacuum pump Dual readout: input and output 4 to 20 ma loop test: auto step and ramp Intrinsically safe

More information

AFC. SDPROC and AFC Analog Mass Flow Controller ANALOG MASS FLOW CONTROLLERS. Principles of Operation. Design Features

AFC. SDPROC and AFC Analog Mass Flow Controller ANALOG MASS FLOW CONTROLLERS. Principles of Operation. Design Features ANALOG MASS FLOW CONTROLLERS Model AF mass fl ow controllers are designed to indicate fl ow rates and control set fl ow rates of gases. Each of these units incorporates an advanced straight tube sensor

More information

NT High-temperature flowmeter model Simultaneous flow and pressure outputs for high-temperature applications

NT High-temperature flowmeter model Simultaneous flow and pressure outputs for high-temperature applications NT High-temperature flowmeter model 4401 Simultaneous flow and pressure outputs for high-temperature applications high-temperature flow measurement Overview Now more than ever there is a need to measure

More information

Additel 761 Automated Pressure Calibrators

Additel 761 Automated Pressure Calibrators Automated Calibrators UPDATED Fully automated pressure calibrator with built-in pressure generator / controller to as high as 600 psi (40 bar) or as low as 0.01 Pa (0.00004 inh 2 O) accuracy Dual pressure

More information

GFM. Typical Aluminum GFM Mass Flow Meter NIST MASS FLOW METERS. Principles of Operation. Design Features

GFM. Typical Aluminum GFM Mass Flow Meter NIST MASS FLOW METERS. Principles of Operation. Design Features Design Features Rigid metallic construction. Maximum pressure of 1000 psig (70 bars). Leak integrity 1 x 10-7 of helium. NIST traceable certification. Built-in tiltable LCD readout. 0-5 Vdc and 4-20 ma

More information

DMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0.

DMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0. Pressure Transmitter for Marine and Offshore Ceramic Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0. % FSO Nominal pressure from 0... 40 mbar up to 0... 0 bar Output signals -wire:

More information

1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure

1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure Siemens AG 204 Overview The pressure transmitter SITRANS P220 measures the gauge pressure of liquids, gases and vapors. Stainless steel measuring cell, fully welded Measuring ranges 2.5 to 600 bar (36.3

More information

Supplementary Operator s Manual 42/24-14 EN Rev. 3

Supplementary Operator s Manual 42/24-14 EN Rev. 3 Advance Optima Continuous Gas Analyzers AO2000 Series with Uras26, Magnos206, Caldos25, Caldos27 Designed per Category 3G for Measurement of Flammable Gases ( Safety Concept ) and Non-flammable Gases Supplementary

More information

Certificate of Compliance

Certificate of Compliance FF0 002 Certificate of Compliance Certificate: 1714037 (LR) Issued to: Emerson Process Management GmbH & Co. OHG Industriestrasse 1 Hasselroth, 63594 GERMANY Attention: Gabriele Blendin The products listed

More information

QBS Electronic Pressure Regulator

QBS Electronic Pressure Regulator INSTALLATION AND MAINTENANCE INSTRUCTIONS DESCRIPTION / IDENTIFICATION The QBS stainless steel series is an electronically controlled pressure regulator. The QBS controls the pressure on its output port

More information

OSAT Series. Intrinsically Safe Infrared Temperature Sensor Operator's Guide

OSAT Series. Intrinsically Safe Infrared Temperature Sensor Operator's Guide OSAT Series Intrinsically Safe Infrared Temperature Sensor Operator's Guide Issue L Jan 2017 Introduction OSAT Series intrinsically safe non-contact infrared temperature sensors measure the temperature

More information

High-performance submersible pressure transmitter For level measurement Model LH-10

High-performance submersible pressure transmitter For level measurement Model LH-10 Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-10 WIKA data sheet PE 81.09 Applications Level measurement in rivers and lakes Deep well

More information

800 Series Mass Flow Meters and Controllers. High Performance Mass Flow Meters and Controllers

800 Series Mass Flow Meters and Controllers. High Performance Mass Flow Meters and Controllers 800 Series Mass Flow Meters and Controllers High Performance Mass Flow Meters and Controllers WHY MASS FLOW? In most processes it is mass, not volume, which is the critical variable. Volumetric flow measurements

More information

Max-Trak Model 180. Technical Data Sheet. NEMA 6 / IP67 Compliant Industrial Mass Flow Meters and Controllers For Gases

Max-Trak Model 180. Technical Data Sheet.   NEMA 6 / IP67 Compliant Industrial Mass Flow Meters and Controllers For Gases NEMA 6 / IP67 Compliant Industrial Mass Flow Meters and Controllers For Gases Features Industry s only NEMA 6/IP67 industrial MFC affords wash down protection eliminating the need for secondary enclosures

More information

780S Ultra High Purity Series

780S Ultra High Purity Series Smart Ultra High Purity Thermal Gas Mass Flow Meter Features Measures mass flow directly, no seperate temperature or pressure inputs required Field adjustment of critical flow meter settings via on-board

More information

Lesman Level Instrumentation LSB100/300 Series Basic Bubbler System

Lesman Level Instrumentation LSB100/300 Series Basic Bubbler System Lesman Level Instrumentation LSB100/300 Series Basic Bubbler System PART 1: GENERAL 1.1 SCOPE A. This section describes the specifications of a bubbler system. B. The following information shall be described

More information

PROCESS ANALYSERS. SERVOPRO PureGas. Gas Purifier. Operator Manual. Part Number: A Revision: 0 Language: UK English

PROCESS ANALYSERS. SERVOPRO PureGas. Gas Purifier. Operator Manual. Part Number: A Revision: 0 Language: UK English PROCESS ANALYSERS SERVOPRO PureGas Gas Purifier Operator Manual Part Number: 02005001A Revision: 0 Language: UK English This page is intentionally blank LIST OF CONTENTS 1 DESCRIPTION AND DEFINITIONS...

More information

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE ATEX CHEMISTRY DIAPHRAGM PUMPS. ATEX VARIO CHEMISTRY DIAPHRAGM PUMPS. Chemistry diaphragm pumps, vacuum systems and gauges for use in

More information

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring. Product Data Sheet CODEL Continuous Emission Monitoring GCEM4100 Extractive Gas Analyser CO, CO2, NO, NO2, SO2, HCL, CH4 & H2O Hot extractive multi-channel gas analyser for continuous process and emissions

More information

Glass tube flowmeters Series 2000

Glass tube flowmeters Series 2000 Glass tube flowmeters Series 2000 Variable area flowmeter for low flows of liquids and gases Short mounting length and compact construction, especially indicated for control panels Easy installation. No

More information

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS Precise and Stable SF 6 Gas Analyzer Simultaneous measurement of humidity, SF 6 purity and SO 2 concentration Integrated gas recovery system with automatic pump back Fully automated SF 6 gas testing Fundamental

More information

3.0 Pressure Transmitter Selection

3.0 Pressure Transmitter Selection 3.0 Pressure Transmitter Selection Each Tronic Line pressure transmitter has different features to meet specific performance, environmental, and price requirements. It is not possible to describe every

More information

GA24 Technical Datasheet

GA24 Technical Datasheet GA24 Technical Datasheet Variable-area flowmeter Sturdy construction for several applications Local indication without auxiliary power Replaceable mounting parts KROHNE CONTENTS GA24 1 Product features

More information

Operating Instructions for Intrinsically Safe Pressure Transmitters Series DMG/******** for Hazardous Application in Coal Mining Industry

Operating Instructions for Intrinsically Safe Pressure Transmitters Series DMG/******** for Hazardous Application in Coal Mining Industry Operating Instructions for Intrinsically Safe ressure Transmitters Series DMG/******** for Hazardous Application in Coal Mining Industry Contents 1. Introduction 2. Abbreviations, symbols 3. Important

More information

Pressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview

Pressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview f gauge pressure Siemens AG 010 Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and electronics plate Process connection Electrical connection

More information

High-performance submersible pressure transmitter For level measurement Model LH-10

High-performance submersible pressure transmitter For level measurement Model LH-10 Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-10 WIKA data sheet PE 81.09 Applications Level measurement in rivers and lakes Deep well

More information

Technical Datasheet. Pressure Transmitter: Analogue Series 387. Performance characteristics. Product applications. How can we help you?

Technical Datasheet. Pressure Transmitter: Analogue Series 387. Performance characteristics. Product applications. How can we help you? Technical Datasheet Pressure Transmitter: Analogue Series 387 387 ISSUE G High Accuracy ± 0.15%. Ranges from 1 bar to 1000 bar. 4 : 1 turndown. 4-20mA analogue with digital communications. 316 stainless

More information

Features. Main Voltage: Vdc. Input Control Signal: 0-5 Vdc or 4-20 madc (Sourcing) Monitor Output Voltage: 0-5 Vdc or 4-20 madc (Sourcing)

Features. Main Voltage: Vdc. Input Control Signal: 0-5 Vdc or 4-20 madc (Sourcing) Monitor Output Voltage: 0-5 Vdc or 4-20 madc (Sourcing) 1 X-Flow Mass Flow Controller Flow Range from 0.8 ml/min to 20 l/min Target Markets Laboratory and Process Instrumentation Pharma / Bio-Pharma Equipment Air Quality Monitoring Systems Furnace and Coatings

More information

Additel 780 Series Pressure Controller

Additel 780 Series Pressure Controller Additel 780 Series Pressure Controller Pressure ranges from vacuum to 3,000 psi (200 bar) Removable interchangeable intelligent sensors Precision accuracy of 0.005% of reading plus 0.005% of full scale

More information

Electropneumatic Transducer (I/P) Installation, Operation and

Electropneumatic Transducer (I/P) Installation, Operation and Nitra NCP1 Series Electropneumatic Transducer (I/P) Installation, Operation and Maintenance Instructions Ordering Information Contents Part Number I/P Transducers Output Range Input psig bar Section Description

More information

Additel 761 Automated Pressure Calibrators

Additel 761 Automated Pressure Calibrators Automated Calibrators UPDATED Fully automated pressure calibrator with built-in pressure generator / controller to as high as 600 psi (40 bar) or as low as 0.01 Pa (0.00004 inh 2 O) accuracy Dual pressure

More information

Tightness controls TC 1 3 and TC 4

Tightness controls TC 1 3 and TC 4 Tightness controls TC 1 3 and TC 4 Test of both safety valves Short test period thanks to logical decision-making in the program sequence Adjustable test period which can be adapted to different systems

More information

Pressure Measurement Single-range transmitters for general applications

Pressure Measurement Single-range transmitters for general applications Siemens AG 206 Overview Design Device structure without explosion protection The pressure transmitter consists of a piezoresistive measuring cell with a diaphragm installed in a stainless steel enclosure.

More information

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/16 Siemens FI US Edition

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/16 Siemens FI US Edition Siemens AG 206 Overview Design Device structure without explosion protection The pressure transmitter consists of a piezoresistive measuring cell with a diaphragm installed in a stainless steel enclosure.

More information

Type S-10, S-11 General Purpose Pressure Transmitters

Type S-10, S-11 General Purpose Pressure Transmitters Electronic Pressure Catalog > General Purpose > S-10, S-11 Type S-10, S-11 General Purpose Pressure Transmitters Applications Hydraulics and pneumatics Test equipment Pump and compressor control Liquid

More information

ellison sensors international

ellison sensors international PR3900 HAZARDOUS AREA PRESSURE TRANSMITTER ATEX CERTIFIED AND ALL EQUIVALENTS FOR HAZARDOUS AREAS: ZONE 0 GAS GROUP IIC, TEMPERATURE CLASS T4 AND ZONE 20 DUST PROTECTION BY INTRINSIC SAFETY TO EEXIA IIC

More information

Micro Motion 7812 Fiscal Gas Density Meter

Micro Motion 7812 Fiscal Gas Density Meter Product Data Sheet PS-001162, Rev. B April 2009 Micro Motion 7812 Fiscal Gas Density Meter Micro Motion density and concentration meters are built to tackle the most demanding process and fiscal applications.

More information

EPP4 Pressure Regulator Basic G 1/4"

EPP4 Pressure Regulator Basic G 1/4 EPP4 Pressure Regulator Basic G 1/4" Flow Curve 1/4" Dimensions Outlet pressure - bar 9 8 7 6 5 4 3 2 1 0 0 20 40 60 70 80 100 120 Flow rate - Nm 3 /h The male connector adopted on the EPP4 is a standard

More information

Additel 780 Series Pressure Controller

Additel 780 Series Pressure Controller Additel 780 Series Pressure Controller Pressure ranges from vacuum to 3,000 psi (200 bar) Removable interchangeable intelligent sensors Precision accuracy of 0.005% of reading plus 0.005% of full scale

More information

7250 Sys. Ruska Multi-Range Pressure Calibration System. GE Sensing & Inspection Technologies. Features. Applications

7250 Sys. Ruska Multi-Range Pressure Calibration System. GE Sensing & Inspection Technologies. Features. Applications GE Sensing & Inspection Technologies 7250 Sys Ruska Multi-Range Pressure Calibration System Features Fully integrated multi-range pressure test and calibration systems Select either an eight range or the

More information

Pressure Measurement Single-range transmitters for general applications

Pressure Measurement Single-range transmitters for general applications Siemens A 207 Overview Application The SITRANS P Compact pressure transmitter is designed for the special requirements of the food, pharmaceutical and biotechnology industries. The use of high-grade materials

More information

EASIDEW TRANSMITTER with Current Source Output

EASIDEW TRANSMITTER with Current Source Output EASIDEW TRANSMITTER with Current Source Output INSTALLATION, OPERATION AND MAINTENANCE MANUAL Issue March 2002 2 TABLE OF CONTENTS SECTION PAGE 1. INTRODUCTION 3 1.1 General 3 1.2 Ceramic Sensing Element

More information

Prewired position switches FA series

Prewired position switches FA series 2 Prewired position switches FA series Selection diagram 01 08 10 11 1 15 1 02 external rubber gasket external rubber gasket 1 51 52 54 55 56 5 ACTUATORS adjustable lever safety adjustable lever 41 45

More information

Columbus Instruments

Columbus Instruments 0215-003M Portable O 2 /CO 2 /CH 4 Meter User s Manual Columbus Instruments 950 NORTH HAGUE AVENUE TEL:(614) 276-0861 COLUMBUS, OHIO 43204, USA FAX:(614) 276-0529 1 www.colinst.com TOLL FREE 1-800-669-5011

More information

ISQB1 INTRINSICALLY SAFE ELECTRO-PNEUMATIC CONTROL VALVE INSTALLATION & MAINTENANCE INSTRUCTIONS HAZARDOUS AREA CLASSIFICATION

ISQB1 INTRINSICALLY SAFE ELECTRO-PNEUMATIC CONTROL VALVE INSTALLATION & MAINTENANCE INSTRUCTIONS HAZARDOUS AREA CLASSIFICATION PROPORTION AIR ISQB1 INTRINSICALLY SAFE ELECTRO-PNEUMATIC CONTROL VALVE INSTALLATION & MAINTENANCE INSTRUCTIONS Hazardous area classification Description / identification General specifications Connection

More information

1 General information Device description Scope Task definition Explosion protection, Device variants...

1 General information Device description Scope Task definition Explosion protection, Device variants... Handbuch/Manual/Manuel/Manuale 12/2002 gas analysis CALOMAT 6 für die Applikation Turbogenerator-Überwachung for the turbo generator monitoring application pour l application Surveillance de turboalternateurs

More information

Liquid level instruments BM 24 /BM 51

Liquid level instruments BM 24 /BM 51 KROHNE 09/2001 7.02362.21.00 GR/PRINTO Liquid level instruments / Status: 10/99 Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters

More information

Oxford Instruments Plasma Technology. PlasmaPro NGP80. Installation Data Sheet. Original Instructions.

Oxford Instruments Plasma Technology. PlasmaPro NGP80. Installation Data Sheet. Original Instructions. Oxford Instruments Plasma Technology www.oxford-instruments.com About this data sheet This data sheet provides basic information about the installation of a tool. Floor and wall loadings Table 1 lists

More information

Continuous Gas Analyzers, extractive

Continuous Gas Analyzers, extractive Overview Plug-in and field device The gas analyzer is primarily used to identify a gas component quantity (e.g. H 2, N 2, Cl 2, HCl, NH 3 ) in binary or quasi-binary gas mixtures. The is specially designed

More information

LMP 307. Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % / 0.

LMP 307. Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % / 0. LMP 07 Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % / 0. % FSO Nominal pressure from 0... mho up to 0... 50 mho Output signals -wire: 4... 0 ma -wire: 0...

More information

OPTIBAR P 1010 C Technical Datasheet

OPTIBAR P 1010 C Technical Datasheet Technical Datasheet Pressure transmitter with recessed diaphragm for general applications Wide variety thanks to modular design Measuring ranges up to 250 bar / 3750 psi High overload and temperature stability

More information

Pneumatic high-pressure controller Model CPC7000

Pneumatic high-pressure controller Model CPC7000 Calibration technology Pneumatic high-pressure controller Model CPC7000 WIKA data sheet CT 27.63 Applications Automotive and avionics industry Industry (laboratory, workshop and production) Transmitter

More information

GEMS SENSORS & CONTROLS

GEMS SENSORS & CONTROLS GEMS SENSORS & CONTROLS OPERATING & INSTALLATION INSTRUCTIONS 31XX / 32XX SERIES PLEASE READ CAREFULLY BEFORE INSTALLING Part Number: 560550-0076 Issue: E INTRODUCTION Series 3100/3200 high output pressure

More information

Technical Data Sheet High Performance Digital Gas Mass Flow Meters and Controllers Features Description

Technical Data Sheet High Performance Digital Gas Mass Flow Meters and Controllers Features Description Smart-Trak Model 100 High Performance Digital Gas Mass Flow Meters and Controllers Features Measure & control gas mass flow rates up to 1000 slpm True digital performance provides high accuracy and great

More information

Pressure Automated Calibration Equipment

Pressure Automated Calibration Equipment GE Measurement & control Pressure Automated Calibration Equipment Safety Instructions and User Guide - K0447 PACE5000 PACE6000 K0447 Issue No. 9 1 10 1 PACE5000 1 2 3 4 5 PACE6000 2 6 7 8 3 4 5 6 7 8 9

More information

Instruction Manual AD 1000 / BA 1000 Absolute Pressure Sensor

Instruction Manual AD 1000 / BA 1000 Absolute Pressure Sensor Instruction Manual AD 1000 / BA 1000 Absolute Pressure Sensor halstrup-walcher GmbH Stegener Straße 10 D-79199 Kirchzarten Phone: +49 (0) 76 61/39 63 0 Fax: +49 (0) 76 61/39 63 99 E-Mail: info@halstrup-walcher.com

More information

Mechanical Pressure Measurement

Mechanical Pressure Measurement Mechanical Pressure Measurement Differential Pressure Gauges Model GDP, Universal Version, with Diaphragm Element High Overpressure Safety PN 40, 100, 250 or 400 Applications Differential pressure measurement

More information

AMT-Ex Dewpoint Transmitter

AMT-Ex Dewpoint Transmitter AMT-Ex Dewpoint Transmitter Instruction Manual Alpha Moisture Systems Alpha House 96 City Road Bradford BD8 8ES England Tel: +44 1274 733100 Fax: +44 1274 733200 email: mail@amsytems.co.uk web: www.amsystems.co.uk

More information

High-performance submersible pressure transmitter For level measurement Model LH-20

High-performance submersible pressure transmitter For level measurement Model LH-20 Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-20 WIKA data sheet PE 81.56 Applications Deep well and borehole measurements Groundwater

More information

Manifolds & pressure reducing sets

Manifolds & pressure reducing sets Manifolds & pressure reducing sets Automatic Changeover Manifold (Electronic) Providing continuous supply of medical gases Pneumatech Medical Gas Solutions (PMGS) PureGAS Manifolds provide a duty or standby

More information

Brooks TMF-Zone 1 Models 5816-Ex/5864-Ex

Brooks TMF-Zone 1 Models 5816-Ex/5864-Ex Data Sheet DS-TMF-586Ex-MFC-eng TMF-Zone Brooks TMF-Zone Models 586-Ex/5864-Ex Customer Benefits Assured process accuracy and repeatability Long-term reliability Reduced maintenance CE certified Improved

More information

JUMO dtrans O2 01 Two-wire Transmitter for dissolved oxygen (DO)

JUMO dtrans O2 01 Two-wire Transmitter for dissolved oxygen (DO) Data Sheet 202610 Page 1/12 JUMO dtrans O2 01 Two-wire Transmitter for dissolved oxygen (DO) with optional terminal box or operating unit Type 202610 Two-wire transmitter JUMO dtrans O2 01 Brief description

More information

dtrans O2 01 Two-wire Transmitter for dissolved oxygen (DO)

dtrans O2 01 Two-wire Transmitter for dissolved oxygen (DO) JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 e-mail: mail@jumo.net Internet: www.jumo.net

More information

PSG 901. Pressure Switch for Gas. elektrogas.com EE141-07/12

PSG 901. Pressure Switch for Gas. elektrogas.com EE141-07/12 PSG 901 Pressure Switch for Gas elektrogas.com EE141-07/12 PSG 901 Pressure Switch for Gas (EN1854) Contents Description... 2 Features... 2 Functioning and application... 3 Technical specifications...

More information

Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC

Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC Mechatronic pressure measurement Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC WIKA data sheet PV 35.41 Process Compact Series Applications Differential pressure monitoring

More information

High-speed pressure sensor Model CPT6140

High-speed pressure sensor Model CPT6140 Calibration technology High-speed pressure sensor Model CPT6140 WIKA data sheet CT 25.11 Applications Testing technology Calibration technology Laboratories and maintenance shops Leak and burst applications

More information

CO, NO, NO 2, NO x, SO 2, CH 4, HCl, CO 2 & H ² O. Extractive low cost, low maintenance devices for continuous process and emissions monitoring.

CO, NO, NO 2, NO x, SO 2, CH 4, HCl, CO 2 & H ² O. Extractive low cost, low maintenance devices for continuous process and emissions monitoring. Product Data Sheet CODEL Continuous Emission Monitoring GCEM 40 Series Extractive Gas Analyser CO, NO, NO 2, NO x, SO 2, CH 4, HCl, CO 2 & H ² O Extractive low cost, low maintenance devices for continuous

More information

Ultra High Purity Model 780S

Ultra High Purity Model 780S Smart Ultra High Purity Thermal Gas Mass Flow Meter Features Measures mass flow directly, no separate temperature or pressure inputs required Built-in flow conditioner which eliminates velocity-profile

More information