ComEx Actuating elements
|
|
- Jayson Gilmore
- 5 years ago
- Views:
Transcription
1 ComEx Actuating elements for Zone and 2 ComEx Actuating elements Features Easy installation Certified for Zone and 2 High IP degree of protection A large number of variants and versions of actuating elements are available for the ComEx control and indicator units. All actuating elements are made of high-quality thermoplastic and conform to the IP / IP 7 type of protection. To complete the actuating elements, there are useful accessories such as e. g. label holders, marking tags, metal shroud or nut wrench. Actuating elements for increased resistance to oil are available too. The actuating elements are mounted quickly and easily onto the ComEx control and indicating devices. Use in Zone and 2 is certified. Explosion protection Ex protection type ATEX II 2G Ex e IIC Gb II 2D Ex tb IIIC Db Certification CML 3 ATEX 300 U IECEx Ex e IIC Gb Ex tb IIIC Db Certification IECEx CML U Further approvals UL, KTL, GOST, INMETRO, DNV, CSA Other approvals and certificates, see Ambient and operating temperature range - C to +70 C Technical data Storage and transport temperature - C to +70 C Protection class min. IP see table Impact resistance 7 Nm (Lamp actuators 4 Nm) Material Enclosure thermoplastic Fastening Installation in enclosures with wall thickness of mm up to mm (threading ). Suitable for through-holes mm /A-0/4-BCS-08/ 0
2 ComEx Actuating elements for Zone and 2 Selection chart for ComEx enclosure Position selector switch** black, with 2 or 3 switch positions with protective collar, lockable only for switch module (2-pole) 0 - I for control unit (flat) for ComEx enclosure I - II for control unit (flat) for ComEx enclosure for Control unit/comex 3L I II for control unit (flat) for ComEx enclosure HAND AUTO for control unit (flat) for ComEx enclosure MAN AUTO for control unit (flat) for ComEx enclosure g 3 boreholes in the protective collar to fit padlocks the switch position 0 (I) or to customer specifications. 4 for ComEx enclosure Double pushbutton actuator** 39 labels red, green, yellow, white, black, supplied loose BN* for control units BN* 2 g - 7 for Control unit/comex 3L /A-0/024-BCS-08/2 3 Pushbutton** BN* labels red, green, yellow, white, black, supplied loose 24 g
3 ComEx Actuating elements for Zone and 2 38 Mushroom pushbutton** black BN* g 38 EMERGENCY STOP** slam button BN* 40 Pushbutton marked "NOT-AUS EMERGENCY STOP" "Pull to Release" DIN EN 04-: 07 DIN EN : 0 (VDE 00 Part 0) 4 g 2 3 Locking mushroom pushbutton** BN* push in without key, unlock with key, DOM lock 4 A 8 70 g /A-0/4-BCS-08/ Lock** DOM lock 4 A 8 Lockable in both positions, Key retractable in both positions BN* Lockable in the depressed position, Key retractable in the depressed position BN* Tip lock lockable in the initial positions, Key retractable in the initial positions BN* 9 g
4 I II ComEx Actuating elements for Zone and 2 2 switching positions Position selector switch BS** black, with 2 or 3 switching positions, turned I for control units BS BS I II (I + II latching) for control units BS BS I II (I + II momentary contact) for control units BS BS 2 I II (I latching, II momentary) for control units BS BS 3 I II (I momentary, II latching) for control units BS BS 3 switching positions g switching positions Key-operated switch** RONIS lock 4, with 2 or 3 switching positions, turned I, latching, for control units key retractable I, momentary contact, for control units Position I key not retractable 7 I II (I + II latching) for control units key retractable g 3 switching positions /A-0/4-BCS-08/4 3
5 ComEx Actuating elements 2 switching positions Position selector switch**, black, with 2 or 3 switching positions 0 - I for control units (latching BN* turned BN* I II for control units (I + II latching) BN* turned BN* 3 switching positions I II for control units (I + II momentary) BN* turned BN* I II for control units (I latching, BN* II momentary contact) turned BN* I II for control units (I momentary BN* contact, II latching) turned BN* 0 - I for control units (momentary) BN* turned BN* 33 g /A-0/4-BCS-08/ M30x. Lamp module actuator** red BN* green BN* yellow BN* white BN* blue BN* 9 g 0 4
6 ComEx Actuating elements 4, 3 Illuminated button actuator** red with EPDM sealing BN* green with EPDM sealing BN* yellow with EPDM sealing BN* 2 white with EPDM sealing BN* blue with EPDM sealing BN* 9 g M30 x, Potentiometer actuator**, black, durable and abrasion-resistant, Scale gradation from 0 to 0 with EPDM sealing BN* 28 g Blanking plug**, to cover unused holes in the cover with EPDM sealing BN* g Mushroom pushbutton**, black with pushbutton label START g /A-0/4-BCS-08/ 3 0
Actuating elements for ComEx
Description A large number of variants and versions of actuating elements are available for the ComEx control and indicator units. All actuating elements are made of high-quality thermoplastic and conform
More informationE10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10. Cable gland Series 8161/7, 8161/8. Installation Equipment and Accessories E10/1.
> Explosion protection type "Increased safety" > Degree of protection IP68 > Ex e and Ex i versions > Integrated blind plug (accessory) for closing unused cable glands > Cable diameter ranges from 1 to
More information4/2 way Pneumatic Solenoid Valve
4/2 way Pneumatic Solenoid Valve Compact design Push-over solenoid coil Exhaust air can be regulated Tube, threaded and sub-base connections Type combined with Seat valve version Type 2508 Type 2510/11
More informationOperating Instructions
LPL Series LED Pendant Lighting Operating Instructions IM0102 COOPER Electronic Technologies (Shanghai) Co., Ltd. No. 955 Shengli Road, East Area of Zhangjiang High-Tech Park, Shanghai 201201 China 1.
More informationFebruary Cable glands For general industry and hazardous areas
February 2017 Cable glands For general industry and hazardous areas Introduction When safety matters, there is only one choice The Nicote and Kopex range of cable glands come to ABB through the acquisition
More information3.1. Ex-e/i Cable Glands Plastic version for Zone 1, 2, 21 and according to EN : 2012
.1 x-e/i Cable Glands Plastic version for Zone 1, 2, 21 and 22 1 - according to N 60079-0: 2012 Conform with latest standards Cable glands with metric screwin threads are now standard and had replace the
More informationJunction Boxes Series 8118
> Enclosure in glass fibre reinforced polyester resin > 3 different sizes available with 4, 5 or as a junction box with integrated miniature fuse: 3 terminals and 1 miniature fuse 7 terminals and 1 miniature
More informationOperating Instructions
Operating Instructions Light-metal Ex d enclosures / flameproof enclosure > 8265/0 Empty enclosure > 8265/4 Control panel, integrated in Ex e enclosure > 8265/5 Control panel Table of Contents 1 Table
More informationConductor Bushings Series 8174
> Current lead-in for Ex d enclosures > 1 to 72 conductors combined in one current lead-in > Series screw-in plug-in > For voltages up to max. 1 V > For size conductor up to 7 mm 2 www.stahl.de 3163E The
More informationHand lever valves VHER
Hand lever valves VHER Hand lever valves VHER Key features Powerful Flexible Practical -M- Flow 170 3800 l/min 4/3-way valve mid-position closed mid-position exhausted mid-position pressurised Connections:
More informationFurther technical information is available on
1 of 5 Manufacture address : Bartec Technor AS Dusavikveien 39 4007 Stavanger Norway Further technical information is available on www.bartec-technor.no Note on instructions When working in hazardous areas,
More informationTechnical Data. General specifications Switching element function Rated operating distance s n 2 mm
0102 Model Number Features 2 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories EXG-12 Quick mounting bracket with dead stop BF 12 Mounting flange, 12 mm Technical Data specifications Switching
More informationIECEx Certificate of Conformity
INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: IECEx CML 14.0034X Issue No:
More informationTechnical Data. Dimensions
00 Model Number Features mm flush Usable up to SIL acc. to IEC 6508 Accessories V-G Female connector, M, -pin, field attachable V-W Female connector, M, -pin, field attachable V-G-N-M-PUR Female cordset,
More informationTechnical Data. Dimensions
0102 Model Number Features 10 mm flush Shielded PUR cable for oil and gas sector Accessories BF 30 Mounting flange, 30 mm Technical Data specifications Switching function Normally closed (NC) Output type
More informationTechnical Data. General specifications. Rated operating distance s n 5 mm
0102 Model Number Features 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories EXG-18 Quick mounting bracket with dead stop BF 18 Mounting flange, 18 mm Technical Data specifications Switching
More informationTechnical Data. Dimensions
0102 Model Number Features Comfort series 15 mm flush Accessories MHW 01 Modular mounting bracket MH 04-2057B Mounting aid for VariKont and +U1+ V1-G-N-2M-PUR Female cordset, M12, 2-pin, NAMUR, PUR cable
More informationCable entries. Contents. Cable entries. Cable entries Introduction C.2 C.1. Standard cable glands - Plastic C.6. Standard cable glands - Brass C.
ontents able entries able entries able entries Introduction.2 Standard cable glands - Plastic.6 Standard cable glands - Brass.9 EM cable glands.15 Standard cable glands - Stainless steel.17 able glands
More informationTechnical Data. Dimensions
00 Model Number Features Comfort series 30 mm non-flush Accessories MHW 0 Modular mounting bracket V-G Female connector, M, 4-pin, field attachable V-W-N-M-PUR Female cordset, M, -pin, NAMUR, PUR cable
More informationTechnical Data. General specifications Switching element function Rated operating distance s n 5 mm
00 Model Number Features 5 mm flush Usable up to SIL acc. to IEC 6508 Accessories V-G Female connector, M, -pin, field attachable V-W Female connector, M, -pin, field attachable V-G-N-M-PUR Female cordset,
More informationTeSys protection components
Presentation, description -pole thermal overload relays TeSys D Presentation TeSys D thermal overload relays are designed to protect a.c. circuits and motors against: b overloads, b phase failure, b excessively
More information1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure
Siemens AG 204 Overview The pressure transmitter SITRANS P220 measures the gauge pressure of liquids, gases and vapors. Stainless steel measuring cell, fully welded Measuring ranges 2.5 to 600 bar (36.3
More informationTechnical Data. Dimensions
0102 Model Number Features Comfort series 15 mm non-flush Stainless steel housing Accessories BF 30 Mounting flange, 30 mm Technical Data specifications Switching element function NAMUR, NC Rated operating
More informationAssembly instruction. Operating temperature range -60 C +85 C Protection. IP 66, 67, 68 (5 bar)
Assembly instruction 1 2 3 4 5 6 7 1. Entry Component 2. Compound Sleeve 3. Interlocking Armour Cone 4. Armour Clamping Ring 5. Gland Body 6. Outer Sheath Sealing 7. Dome Nut 8. Compound 8 Operating temperature
More informationTechnical Data. Dimensions
0102 Model Number Features Comfort series 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories BF 18 Mounting flange, 18 mm EXG-18 Quick mounting bracket with dead stop Technical Data specifications
More informationTechnical Data. Dimensions
0102 Model Number Features 2 mm flush Usable up to SIL2 acc. to IEC 61508 Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 2 mm Installation flush Output
More informationPart I -Installation Tools Needed Screwdriver/Adjustable Wrench to 1-1/2 MOUNTING
120 Series Explosion-Proof Pressure and Differential Pressure Switches Types J120, J120K, H121, H121K, H122, H122K, H122P U N I T E D E L E C T R I C C O N T R O L S Installation and Maintenance Instructions
More informationIP 69 Protection against water under pressure
44 he European echnical Standard DIN EN 50 262 Metric cable glands for electric installations - the end of the PG Cable glands threads. he technical standards Cable Glands for cables and conductors with
More informationHigh-performance submersible pressure transmitter For level measurement Model LH-20
Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-20 WIKA data sheet PE 81.56 Applications Deep well and borehole measurements Groundwater
More informationPressure Switches Application Guideline
Pressure Switches Application Guideline Product Overview The Fema Pressure Switch product portfolio provides devices suitable for many applications. The portfolio contains Special functions and equipment
More informationTechnical Data. General specifications Switching element function Rated operating distance s n 1.5 mm
0102 Model Number Features 1.5 mm flush Accessories BF 8 Mounting flange, 8 mm Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 1.5 mm Installation flush
More informationDimensions. Technical Data General specifications Switching element function Rated operating distance s n 5 mm
Dimensions M18x1 37 40 4 0102 24 LED Model Number Features 5 mm embeddable Usable up to SIL2 acc. to IEC 61508 Connection BN BU Accessories L+ L- EXG-18 Quick mounting bracket with dead stop BF 18 Mounting
More informationPart I -Installation Tools Needed Screwdriver/Adjustable Wrench to 1-1/2 MOUNTING
120 Series Explosion-Proof Pressure and Differential Pressure Switches Types J120, J120K, H121, H121K, H122, H122K UNITED ELECTRIC CONTROLS Installation and Maintenance Instructions Please read all instructional
More informationHigh-performance submersible pressure transmitter For level measurement Model LH-20
Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-20 WIKA data sheet PE 81.56 Applications Deep well and borehole measurements Groundwater
More informationArran LED Floodlight Luminaire
Arran LED Floodlight Luminaire INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS Important: Please read these instructions carefully before installing or maintaining this equipment. Good electrical
More informationDual Modular Safety Shutoff Valves. DMV-D/11 Series DMV-DLE/11 Series
Dual Modular Safety Shutoff Valves DMV-D/11 Series DMV-DLE/11 Series Two normally closed safety shutoff valves in one housing; each with the following approvals. CSA Certified ANSI Z21.21 CSA 6.5 Marked
More information1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/16 Siemens FI US Edition
Siemens AG 206 Overview Design Device structure without explosion protection The pressure transmitter consists of a piezoresistive measuring cell with a diaphragm installed in a stainless steel enclosure.
More informationEx-proof solenoid valves with spool position monitor on/off, with inductive proximity sensor - Multicertification ATEX, IECEx, EAC
www.atos.com Table -2/E Ex-proof solenoid valves with spool position monitor on/off, with inductive proximity sensor - Multicertification TEX, IEEx, E valve body spool ex-proof solenoid ex-proof inductive
More informationATM.ECO/IS - Analog Transmitter with Temperature compensation
Pressure Transmitter - FM / FM-C certified ATM.ECO/IS - Analog Transmitter with Temperature compensation CUSTOMER BENEFITS Certificate: FM, FM-C & IECEx & ATEX Entry level series into precision pressure
More informationReg No: 1999/027771/07 ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS
Government Approved Test Laboratory (Previously AIA) Reg No: 1999/027771/07 ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS ZEST
More informationPressure Measurement Single-range transmitters for general applications
Siemens AG 206 Overview Design Device structure without explosion protection The pressure transmitter consists of a piezoresistive measuring cell with a diaphragm installed in a stainless steel enclosure.
More information120 Series Explosion-Proof Pressure and Differential Pressure Switches
120 Series Explosion-Proof Pressure and Differential Pressure Switches Types J120, J120K, H121, H121K, H122, H122K SIL2 Certified UNITED ELECTRIC CONTROLS Installation and Maintenance Instructions Please
More informationSeries CGZT three-jaw grippers with T-guide
Series CGZT three-jaw grippers with T-guide New Single and double acting, magnetic, self-centering Sizes: 40, 50, 64, 80, 100, 125, 160 mm The new Series CGZT pneumatic grippers, thanks to the use of a
More informationZ, Y, and X PURGE INDICATORS / CONTROLLERS
PurgEx XXXXXX Z, Y, and X PURGE INDICATORS / CONTROLLERS PURGE / PRESSURIZATION PURGE / PRESSURIZATION XXXXX XXXXXXXXX 8626 SERIES Globally Certified Z,Y,X Purge Indicators / Controllers and Accessories
More informationHigh-performance submersible pressure transmitter For level measurement Model LH-20
Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-20 WIKA data sheet PE 81.56 Applications Deep well and borehole measurements Groundwater
More informationSeries CGCN self-centering three-jaw grippers with T-guide
HANDLING AND VACUUM 2019 GRIPPERS > Series CGCN self-centering three-jaw grippers with T-guide New Double acting, magnetic Sizes: 50, 64, 80, 100, 125 mm The new Series CGCN pneumatic grippers are available
More informationOperating Instructions
Operating Instructions Ex d Enclosures in Light Metal / Flameproof Encapsulation > 8265/0 Empty Enclosure > 8265/4 controller, installed in Ex e enclosure > 8265/5 controller Contents 1 Contents 1 Contents...2
More informationPressure switch, Differential pressure switch and Thermostat RT-E
Data sheet Pressure switch, Differential pressure switch and Thermostat RT-E The RT-E series consist of pressure and differential pressure switches as well as thermostats. The units are designed for industrial
More informationCable entries. Contents. Cable entries. Cable entries Introduction L.2 L.1. Standard cable glands - Plastic L.5. Standard cable glands - Brass L.
Contents Introduction.2 Standard cable glands - Plastic.5 Standard cable glands - Brass.7 EMC cable glands.14 Standard cable glands - Stainless steel.16 Cable glands for Ex applications - Brass.17 Adaptors.18
More informationTechnical Datasheet. D Series SMART Pressure Transmitter Model: DPC D-Series. Key Features. Series Overview. Product applications
Technical Datasheet D Series SMART Pressure Transmitter Model: DPC-2000 Key Features ATEX - Flameproof and Intrinsically Safe IECEx - Flameproof and Intrinsically Safe SIL 2 certificate Compliant to NAMUR
More informationABTQ-110 rev 00 (Last review: 28 Aug 12) INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS FOR ABTECH S RANGE ENCLOSURES IECEx SIR U SERIAL No
ABTQ-110 rev 00 (Last review: 28 Aug 12) INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS FOR ABTECH S RANGE ENCLOSURES IECEx SIR 05.0046U SERIAL No 20 TYPE SX Ex e II C Gb Ex tb IIIC Db IP6* IECEx SIR
More information(Certification N:o VTT 08 ATEX 066 or IECEx VTT )
(Certification N:o VTT 08 ATEX 066 or IECEx VTT 12.0009) Thank you for choosing Slam Hornet portable work light for your job site. Purpose of this manual is to provide you all the necessary safety and
More informationSITRANS P measuring instruments for pressure
SITRANS P measuring instruments for pressure Z series for gage pressure Siemens AG 008 Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and
More informationTechnical Data. General specifications. Rated operating distance s n 2 mm
0102 Model Number Features 2 mm flush Usable up to SIL 2 acc. to IEC 61508 Technical Data specifications Switching function Normally closed (NC) Output type NAMUR Rated operating distance s n 2 mm Installation
More informationEX-RECESSED CEILING LIGHT FITTINGS
EX-RECESSED CEILING LIGHT FITTINGS RLF/RLF-INOX 250 18-58 W / RLF/RLF-INOX 250... N 18-36 W Metallic design for Zone 1 and Zone 21 The RLF... explosion-protected recessed ceiling light fittings with electronic
More informationPushbuttons and Indicating Lights
Pushbuttons and Indicating Lights Pushbuttons Indicating Lights Emergency Stops Selector Switches.5 Product Overview.............................................. 2 Product Selection Guide.........................................
More informationSubmersible pressure sensor High-performance Model LH-20
Level Submersible pressure sensor High-performance Model LH-20 WIKA data sheet PE 81.56 Applications Deep well and borehole measurements Groundwater monitoring Level measurement in open bodies of water
More informationATM.1ST/Ex - High Precision Transmitter
Pressure Transmitter - ATEX / IECEx certified ATM.1ST/Ex - High Precision Transmitter CUSTOMER BENEFITS Certificate: ATEX, IECEx & EAC High measurement accuracy is ensured by sophisticated digital temperature
More informationSafety Instructions Liquiphant FailSafe FTL80, FTL81, FTL85
XA01537F-A/00/EN/01.16 71333275 Products Solutions Services Safety Instructions Liquiphant FailSafe FTL80, FTL81, FTL85 0Ex ia IIC T6 Ga X Ga/Gb Ex ia IIC T6 X Document: XA01537F-A Safety instructions
More informationInstructions for Safe Use
Instructions for Safe Use Certification N:o VTT 14 ATEX 041X and IECEx VTT 14.0004X Thank you for choosing SLAM Hornet portable work light with battery back up for your job site. Purpose of this manual
More informationLMP 307. Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % / 0.
LMP 07 Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % / 0. % FSO Nominal pressure from 0... mho up to 0... 50 mho Output signals -wire: 4... 0 ma -wire: 0...
More informationLimit switches OsiSense XC Special For material handling applications, type XC1 AC
Presentation For material handling applications, type XC C b XC C with slow break contacts v With head for linear movement () 00_ 00_ 000_ Page / 00_ 00_ XCC XCC Page / XCC XCC / General characteristics
More information3G Operating instructions. Digital Purge Gas Valve 3G Type: Document no.: D0001 Version: 01. July 2011/Rev.
3G Operating instructions Type: 03-5110-00.. Document no.: 03-5110-7D0001 Version: 01. July 2011/Rev. 0 Operating Instructions Type: 03-5110-00.. Document no.: 03-5110-7D0001 Version: 1 July 2011 / Rev.
More informationAvailable models Devices Color White sealing bellows Black sealing bellows NDT SW NDT GB NDT RT NDT GN NDT WS NDT BL NDT GR
Pushbuttons Left: type series N with sealing bellows, color white (standard). Right: type series N with sealing bellows, color black. Protective collar against unintentional actuation: refer to page 58
More informationTechnical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection
0102 Model Number Features Direct mounting on standard actuators Compact and stable housing Fixed setting EC-Type Examination Certificate TÜV99 ATEX 1479X Usable up to SIL2 acc. to IEC 61508 Accessories
More information2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure
Z series for gage pressure Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and electronics plate Process connection Electrical connection
More informationHigh-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20
Electronic pressure measurement High-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20 WIKA data sheet PE 81.56 Applications Deep well and borehole measurements
More informationHydrostatic. Continuous level measurement. Overview Page 188 VEGAWELL 52 Page 190 VEGABAR 86, 87 Page 192 Accessory Page 196 AL-EN
Hydrostatic Continuous level measurement 8 Overview Page 188 VEGAWELL 52 Page 190 VEGABAR 86, 87 Page 192 Accessory Page 196 187 Hydrostatic Level and pressure measurement Measuring principle The pressure
More informationElectropneumatic Positioner Type 4763 Pneumatic Positioner Type 4765
Electropneumatic Positioner Type 4763 Pneumatic Positioner Type 4765 Application Single-acting positioner for attachment to pneumatic control valves. Supplied with either an electric input signal from
More informationElectropneumatic Positioner and Pneumatic Positioner Type 3760 JIS
Electropneumatic Positioner and Pneumatic Positioner Type 3760 Application Single-acting positioners for direct attachment to pneumatic control valves. Supplied with an electric input signal of 4 to 20
More informationPart I - Installation
120 Series Explosion-Proof Temperature and Indicating Temperature Switches and Controls Local Mount Types B121, B122, C120 Remote Mount Types E121, E122, F120; 820E, 822E UNITED ELECTRIC CONTROLS Installation
More informationPart I - Installation
120 Series Explosion-Proof Temperature and Indicating Temperature Switches and Controls Local Mount Types B121, B122, C120 Remote Mount Types E121, E122, E122P, F120; 820E, 822E U N I T E D E L E C T R
More informationDimensions. Technical Data General specifications Switching element function Rated operating distance s n 10 mm
Dimensions M30x1,5 5 40 37 0102 Model Number 36 LED Features Comfort series 10 mm embeddable Connection BN BU Accessories BF 30 Mounting flange, 30 mm L+ L- Technical Data specifications Switching element
More informationOIL+GAS PRODUCTS AND THEIR APPLICATIONS
OIL+GAS PRODUCTS AND THEIR APPLICATIONS FIELDS OF APPLICATIONS AND REQUIREMENTS OIL RIGS SHIP AND SHIP EQUIPMENT Oil rigs have extremely high requirements for the technology used. Even the smallest spark
More informationFULL STAINLESS STEEL EXPLOSION-PROOF SOLUTIONS OIL & GAS I OFFSHORE AND ONSHORE
FULL STAINLESS STEEL EXPLOSION-PROOF SOLUTIONS OIL & GAS I OFFSHORE AND ONSHORE ASCO Numatics ASCO Numatics is the world leader in design, manufacturer of solenoid valves and accessories for both offshore
More informationCost effective. Smooth. Reliable. LOG Internal Hole Gripper
LOG Cost effective. Smooth. Reliable. LOG Internal Hole Gripper Light gripper made of very resistant polyamide with closed diaphragm system Field of Application Particularly suited to highly dynamic applications
More informationIPH 2 & IPX 2. Features Type 4X & Explosion-Proof Current-to-Pressure (I/P) Transmitters. Approved for Use with Natural Gas.
February 2018 Description These 2-wire (loop-powered) I/P transmitters accept a current signal (such as 4-20mA) from a DCS, PLC or PC-based control system. They convert the current signal to a pneumatic
More informationRelative pressure transmitter type 520
Relative pressure transmitter type 520 Pressure range -1... 9 bar / 0... 2.5 1000 bar The compact type 520 pressure transmitter is based upon the Huba Control developed thick film technology where the
More informationPushbuttons and Pilot Lights
Pushbuttons and Pilot Lights Pushbuttons and Pilot Lights - CSW Series (Ø 22mm) Nº Description 1 Double Pushbutton 2 Protection Cover for Double Pushbutton 3 Flush lluminated Pushbutton 4 Flush Pushbutton
More informationCompact differential pressure switch Flameproof enclosure Ex d Models DE, DEC
Mechatronic pressure measurement Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC WIKA data sheet PV 35.41 Process Compact Series Applications Differential pressure monitoring
More informationFloodlight LED. Series Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN
Floodlight LED Operating instructions Additional languages www.stahl-ex.com General Information Contents 1 General Information...2 1.1 Manufacturer...2 1.2 Information regarding the operating instructions...3
More informationPressure Switch for gas and air
Switch for gas and air GAO-A4 GMH-A4 GML-A4 UL Listed UL 353 File # MH 16628 CSA Certified CSA C22.2 No. LR 53222 Certification file # 201527 FM Approved Class 3510, 3530 File # J.I. 1Y919.AF Commonwealth
More informationPull-rope emergency stop switch Type HENEX and SEGEX OPERATING INSTRUCTIONS
Pull-rope emergency stop switch Type OPERATING INSTRUCTIONS Legal Notice (Translation of the original) Document No.: 94.058 816.191 Pull-rope emergency stop switch, Type HENEX and SEGEX Product number:
More informationPrewired position switches FA series
2 Prewired position switches FA series Selection diagram 01 08 10 11 1 15 1 02 external rubber gasket external rubber gasket 1 51 52 54 55 56 5 ACTUATORS adjustable lever safety adjustable lever 41 45
More informationFloodlight LED. Series Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN
Floodlight LED Operating instructions Additional languages www.r-stahl.com Contents 1 General Information...3 1.1 Manufacturer...3 1.2 Information regarding the operating instructions...3 1.3 Conformity
More informationType N-10, N-11 Hazardous Area Non-incendive Transmitters
Electronic Pressure Catalog > Hazardous Area > N-10, N-11 Type N-10, N-11 Hazardous Area Non-incendive Transmitters Applications Natural gas compressors Wellhead monitoring Pipeline pressure General industrial
More informationSIGNUM 3SB3 Pushbutton Units and Indicator Lights
SIGUM SB Pushbutton Units and Indicator Lights Contact blocks and lampholders Contact block with contact Version Symbol Contact travel contact closed contact open with screw terminals, for front plate
More informationACCESSORIES. Standard packing
ACCESSORIES HC RELAYS (Sockets and Terminal ) FEATURES. HC Relay Sockets In the table below, the suitable for each type of HC relay is indicated by a black dot. ) Plug-in type, type, and wrapping type
More informationUltrasonic. 58 Overview VEGASON 60 VEGASON 61, 62, 63
Ultrasonic 58 Overview VEGASON 60 VEGASON 61, 62, 63 57 Overview VEGASON Area of application The ultrasonic sensors of the VEGASON series are suitable for non-contact level measurement of liquids and bulk
More informationF series Foot Switches
F series Foot Switches ITC presents a complete line of foot switches from Bernstein, designed to respond to the most stringent requirements for machine control and safety applications. The F series includes
More informationOperating instructions. Steuerung SILAS Control unit Type: A /...; Pressure monitor Type: 17-51P3-1604
Operating instructions Steuerung SILAS Control unit Type: A7-3741-1110/...; Pressure monitor Type: 17-51P3-1604 Document no.: A1-3741-7D0001 Version: 31 March 2017 / Rev. F Operating Instructions SILAS
More informationData Sheet B-Series Switches Pressure, Differential Pressure & Hydraulic
FEATURES Adjustable setpoints 15-100% of range Fixed or limited adjustable deadband Wide selection of switch elements Explosion proof enclosure provides uncompromising protection Special designs for NACE
More informationDimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm
Dimensions 65 GW2 40 35 9 5 GW1 14 11 9 5.4 M20 x 1.5 0102 Model Number S M12 x 1.5 Features 77.5 LED V Direct mounting on standard actuators Compact and stable housing with terminal compartment connection
More informationATM/Ex - Intrinsically Safe Analog Pressure Transmitter - ATEX / IECEx Certified
Intrinsically safe pressure transmitters ATM/Ex - Intrinsically Safe Analog Pressure Transmitter - ATEX / IECEx Certified CUSTOMER BENEFITS Certificate: ATEX & IECEx Fast customization thanks to configurable
More informationMeta-MEC Manual Motor Starters
www.lsis.biz Meta-MEC Manual Motor Starters LS Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 45 mm 70 mm 63AF 100AF 3 LS Meta-MEC Manual Motor Starters deliver more
More informationELECTRIC ACTUATORS for continuous underwater use
ELECTRIC ACTUATORS for continuous underwater use The SA multi-turn actuator for continuous underwater use by AUMA opens new applications for electric actuators for water supply, in hydropower plants and
More informationOPERATION MANUAL PNEUMATIC VALVES
OPERATION MANUAL PNEUMATIC VALVES DIRECTIVE 2014/34/EU ATEX ENGLISH Index 1 Product identification 2 Security 3 Guarantee 4 Transportation 5 Assemblage 6 Setting up 7 Adjustments 8 Technical information
More informationGas Pressure Regulator HON 300
Product information serving the gas industry worldwide Applications, characteristics, technical data Applications direct acting gas pressure regulator, for systems in accordance with DVGW working instruction
More informationPressure regulators Manually operated Fine setting valves. Brochure
Pressure regulators Manually operated s Brochure Pressure regulators Manually operated s Qn = 9 l/min Actuating element: Push button Internal thread Poppet valve Qn = 9 l/min Actuating element: Push button
More informationOSAT Series. Intrinsically Safe Infrared Temperature Sensor Operator's Guide
OSAT Series Intrinsically Safe Infrared Temperature Sensor Operator's Guide Issue L Jan 2017 Introduction OSAT Series intrinsically safe non-contact infrared temperature sensors measure the temperature