RW series. Clogless impeller-fitted centrifugal pumps
|
|
- Leonard James
- 5 years ago
- Views:
Transcription
1 RW series Clogless impeller-fitted centrifugal pumps
2 DESCRIPTION RW pumps are centrifugal, monocellular, with axial suction and radial delivery. They offer two kinds of performance: - Horizontal on a frame - Vertical with a shaft and base plate A carefully studied design means that up to three different impellers can be fitted to one same model of pump (with channels, open or vortex), thereby resulting in a versatile and functional range adapted to each kind of liquid pumped. It is advisable to fit to the suction port, an inspection and cleaning flanged handhole, which is available as an option on request. APPLICATIONS The RW series has been designed to satisfy demands in the field of waste and loaded liquids. It is therefore highly suitable for: Paper mills Water for screenings Water containing pulp Cellulose, etc. Sugar mills and canning factories Thick soaked malt Water and cereal mixtures Vegetable waste, etc. Construction Cleaning tanks Water containing cement and fibres Untreated drainage Waste water and sewage, etc. Mining Fine and coarse silt Milk of lime Water containing coal and minerals Kaolin sludge Water containing earth, slime, etc. Chemical industries Chemical products containing dirt Chemical products containing glass (phosphates, etc.) Potashes Brines, bleaches, etc. EXTENT OF SERIES The RW Series by Bombas ITUR has a total of 28 different models, split into 14 sizes, some of which can be fitted with two or three kinds of impeller. Service limits: - Maximum flow: m 3 /h - Maximum head: m.c.a. - Maximum casing pressure: bar - Maximum temp. standard performance ºC special performance ºC CONSTRUCTION Voluted body with feet and flange connections DIN-2501, PN-16, with RF finish according to DIN-2526 form C. Projecting impeller with body wear ring. Special versions with cooling or heating chambers are also available. The support is of hardwearing construction, with one double row of ball bearings on the motor side, and another row of rollers on the pump side. These are standardised and calculated to have a working life of over 20,000 hours. Pumps with the a impeller have an axially adjusted support. Types of impellers Closed impeller with two or three channels (Impeller c ) For waste water containing solids and slimy liquids with suspended matter, which neither create gas nor contain fibres that could cause the appearance of braiding. Either two or three channels are used depending on the kind and size of pump. Open, multivane impeller (Impeller a ) For slightly dirty liquids that can also contain gas or air. Liquid outlets from the sugar industry, containing suspended matter, up to 6% in consistency (solid matter). Free passage impeller ( Vortex ) (Impeller v ) Liquids containing a wide variety of gases. Water containing solids, for spinning waste and mixtures that tend to cause the appearance of braiding. Impeller c (two or three channels) PUMP DENOMINATION Kind of impeller (c-a-v) Size of pump iimpeller a (open multivane) RW series Impeller v (of the Vortex type) 2
3 WATERTIGHTNESS OF THE SHAFT Based on the most common gasket-including constructions, 7 standardised variations ensure that the shaft is completely watertight. The use of one or another version depends on the characteristics of the fluid to be pumped. The seven standardised versions are: 1.- Gasket with casing and an orifice for external fluid. When the pump is operating in suction mode, the external fluid must be grease or another similar liquid compatible with that being pumped. For clean water, the connection can be made from the impeller. Loaded waters require the external injection of clean water. 2.- Gasket with casing, a base ring and an orifice for external fluid. For abrasive or highly loaded water, replace the first gasket ring with a base ring. The exterior clean liquid prevents the pumping from affecting the gasket. 3.- Gasket with casing and two orifices for exterior circulation. This device is used when the sealed fluid has not to come into contact with that being pumped. It has an inlet and an outlet to facilitate the circulation of the exterior liquid. 4.- Simple mechanical lock in keeping with DIN without external liquid, with subsequent washing. Plan API-11. It makes no difference whether the operation is functioning in suction or in load mode. This system is used for relatively clean liquids. Subsequent washing (quenching), if required, is available as an option with the corresponding connection on the locking cap. 5.- Simple mechanical lock in keeping with DIN 24960, with external liquid and subsequent washing. Plan API-32. This system avails of continuous circulation with clean external liquid. It is used for dirty liquids. Subsequent washing (quenching), if required, is available as an option with the corresponding connection on the locking cap. 6.- Double mechanical back-to-back lock. Plan API-54. A lock for abrasive, dangerous liquids etc. It is the external liquid that creates a barrier. It must be injected at a pressure higher than that existing behind the impeller and must be compatible with the liquid being pumped. 7.- Double mechanical tandem lock. Plan API-1 with posterior barrier fluid. A lock for abrasive, dangerous and especially toxic liquids. It is the external liquid that creates a barrier. This liquid has to be injected at low pressure, but does not have to be compatible with the liquid being pumped. An alarm system can be fitted to the barrier circuit so that, should the first lock leak, causing a rise in pressure within the circuit, the alarm would go off and in turn oblige the pump to stop Miscellaneous Other special devices are also available as an option, depending on the fluid to be pumped. Consult our Technical Department. 3
4 STANDARDISED MATERIALS OPERATING CODE (*) Ref. Part 1600 GG MIXED 1602 MISTINOX 1603 BRONZE 1604 NODULAR MISTIBRAS 1607 CA6NM 1608 AISI L 1610 CN7M 1621 IMPBRON 1622 EJENOX 1112 Pump body GG-25 RG-5 GGG-40 GG-25 CA6NM GG Impeller GG-25 GSnBz10 GSnBz10 GG-25 1 Body wear ring GG-25 RG-5 RG-5 GG-25 CA6NM AISI-329 L A743CN7M SN-10 GG Pump shaft F-114 F Renewable bushing 3130 Bearing support AISI-431-B GG L * For other materials (A216-WCB, Monel, Hastelloy, NI-Resist, etc.) consult our Technical Dept. INTERCHANGEABILITY OF PARTS The components appearing in the left-hand column of the table are standard and can be used on any model of pump bearing the same letter as the component in question. The advantage of this standardisation lies in that a minimum stock of parts guarantees the maintenance and fast repair of many different models of pump. Example: the shaft of pump 50/200 is the same as it is on pumps 85/ and 80/200. Ref. Description TYPE OF PUMP Gasket-holding cap Support foot Shaft Renewable bushing Impeller-fixing nut Bearing support Front bearing Rear bearing Front bearing cap Rear bearing cap Support casing Stuffing box Gasket Casing ring A B B C D E F C E G H G H I A B C D E F D G F H I J H H A B B C D E D C E F G F G E TECHNICAL SPECIFICATIONS Item TYPE OF PUMP Max. impeller ø (mm) Max. r.p.m. Cut-off impeller (mm) Max. r.p.m. TempºC standard performance TempºC with cooling chamber Momentum (kg.m 2 ) Weight of the pump (kg) c Impeller pitch (mm) a v Maximum torque (kg.m) 169 ø 209 ø 209 ø 320 ø 260 ø 404 ø 260 ø 320 ø 404 ø 504 ø 320 ø 504 ø 320 ø 404 ø ø 230 ø 435 ø 435 ø < TºC < +120 TºC < ,0313 0,064 0,095 0,148 0,215 1,1 0,27 0,75 1,23 2,62 0,72 2,85 0,867 2, (1) (1) (1) (1) (1) (1) 8,76 20,43 20,43 48,65 20, ,65 20, NOTE.- (1) The design of the Vortex V version lets all solids through, no matter what the physical width of the impeller. (2) The data given in this table corresponds to material operating in GG-25 (code 1600), with water at 20ºC and a specific weight of kg/cm 3. For other working conditions, consult our Technical Department. 4
5 EASY TO MAINTAIN The careful design of the elastic coupling with spacer permits fast and easy access to the pump interior without having to disconnect the pipes or the motor. Once the spacer has been released, it is possible to dismantle the unit comprising the support, the cap and the impeller, always leaving the body and the motor fixed to the frame. The suction and delivery pipes will remain flanged. DIAGRAMS FOR SELECTING THE MODEL The following diagrams show the general performances of flow and head at 950, 1,450 and 2,900 r.p.m. corresponding to the 14 sizes of pump with a closed impeller of two or three channels, type c. For more detailed information on output, absorbed power and required NPSH, ask for our particular curves for each pump with its corresponding impeller. This therefore makes it easy to maintain pumps that require attention more often than normal when working with dirty liquids. 5
6 PUMP BREAKDOWN Ref Name of the part Upper pump body Gasket-holding cap Body wear ring Shaft Impeller Renewable bushing Impeller-fixing nut Rear bearing Front bearing Bearing support Support casing Support foot Front bearing cap Rear bearing cap Oil-filling cap Level adjuster Stuffing box Gasket Internal ring Section plan of pump RW with channel impeller, c type, and gasket. Detail with Vortex, v type, impeller. Detail with open, multivane, a type impeller Support with axial adjustment 6
7 DIMENSIONS TYPE OF PUMP Flanges Pump data 50/ / / / / / / / / / / / / / Foot data Shaft end Handhole DNs DNd a f 1 h 1 h 2 b m 1 m 2 n 1 n 2 n 3 s 1 s 2 g 1 g 2 w y d 1 l 1 t 1 u 1 p p NOTE: Pumps ITUR operates on a policy of continuous improvement to the development of its models. Modifications may therefore be made to the specifications without prior warning ,9 35, , , , , , , , , , ,2 18 7
8 Horizontal operation, on a frame with an electric motor and elastic coupling with a spacer. Vertical operation, with a shaft, base plate and delivery piping. RWCP Series. BOMBAS ITUR, S.A. P. O. Box, ZARAUTZ (Gipuzkoa) SPAIN Tel.: Fax: E.mail: comexp@itur.es CI-RW/A140-5 (04/03)
Dean Pump Self-Priming Chemical Process Pumps
Bulletin C 1.2.34.7 Dean Pump Self-Priming Chemical Process Pumps php Series HEAD CAPACITY RANGE CHARTS php Self Primer - 2 Pole 3500 RPM 500 CAPACITY M 3 /HR 2900 RPM 50 HERTZ 25 50 75 125 150 400 TOTAL
More informationSIHI LPH-X - Liquid Ring Compressors
- Liquid Ring Compressors LPH 50523 LPH 60527 Pressure range: Suction volume range: 0.2 to 1.5 bar 260 to 780 m³/h CONSTRUCTION Sterling SIHI liquid ring compressors are displacement compressors with a
More informationMZT PUMPI PUMP YOUR WAY TO SUCCESS MULTISTAGE CENTRIFUGAL PUMPS - MS,DMS,MSTD,MSS
UM YOUR WAY TO SUCCESS MULTISTAGE CENTRIFUGAL UMS - MS,DMS,MSTD,MSS Catalog 9 CONTENT GENERAL DATA.................................................... 3 Description.......................................................
More informationDISASSEMBLY AND ASSEMBLY INSTRUCTIONS FOR LIQUID RING COMPRESSORS
DISASSEMBLY AND ASSEMBLY INSTRUCTIONS FOR LIQUID RING COMPRESSORS SA INTRODUCTION These instructions are for the maintenance personnel for maintenance and repair of compressors series SA. Disassembly and
More informationDisplacement 12, , Maximum flow rate (at 1450 rpm) bar.
00/07 ED PVD VARIABLE DISPLACEMENT VANE PUMPS SERIES 0 OPERATING PRINCIPLE The PVD pumps are variable displacement vane pumps with a mechanical type of pressure compensator. They allow instantaneous adjustment
More informationDesign. Pompetravaini-NSB API SB Liquid Ring Compressor for Gas Processing. Working Principle
SB Pompetravaini-NSB API SB Liquid Ring Compressor for Gas Processing A family of API liquid ring compressors has been developed and has been in the market for nearly a decade, they are specifically made
More informationBall Float Steam Trap UNA 43 PN 16/CL 125/JIS 10K UNA 46 PN 40/CL 150/CL 300/JIS 10K/JIS 20K DN 80, 100, 150, 3", 4", 6"
Data Sheet 819584-00 Issue Date: 01/17 Ball Float Steam Trap UNA 43 PN 16/C 125/JIS 10K UNA 46 PN 40/C 150/C 300/JIS 10K/JIS 20K DN 80, 100, 150, 3", 4", 6" UNA 43 hl, UNA 46 hl UNA 43 v, UNA 46 v with
More informationFixed Displacement Pump KFA for commercial vehicles in open circuits
RE 91 501/05.98 Replaces: 11.96 Fixed Displacement Pump KFA for commercial vehicles in open circuits Sizes 23...107 Series 6 Nominal pressure 300 bar Peak pressure 350 bar KFA List of contents Features
More informationPROCESS ROTATING EQUIPMENT (CENTRIFUGAL PUMPS )
PROCESS ROTATING EQUIPMENT ( ) Slide No: ١ Pumps can be divided into two main groups: Displacement pumps Dynamic pumps Slide No: ٢ Slide No: ٣ Slide No: ٤ Slide No: ٥ BASIC CENTRIFUGAL PUMP PARTS Casing
More informationLiquid ring compressors
Liquid ring compressors KPH 85220, KPH 85227 Compression pressures: Suction volume flow: 2 to 7 bar 940 to 1450 m³/h CONSTRUCTION TYPE Sterling SIHI liquid ring compressors are displacement compressors
More informationLiquid ring compressor
Liquid ring compressor KLH 47005, KLH 47105 Compression pressures: Suction volume flow: 2 to 11 bar 56 to 65 m³/h CONSTRUCTION TYPE Sterling SIHI liquid ring compressors are displacement compressors of
More informationSeated valves (PN 6) VL 2 2-way valve, flange VL 3 3-way valve, flange
Data sheet Seated valves (PN 6) VL 2 2-way valve, flange VL 3 3-way valve, flange Description VL 2 VL 3 VL 2 and VL 3 valves provide a quality, cost effective solution for most water and chilled applications.
More informationSeated valves VRB 3, VRG 3
Data sheet Seated valves VRB 3, VRG 3 Description VRB, VRG valves provide a quality, cost effective solution for most water and chilled applications. These valves may be used with glycol concentrations
More informationCompressors. Basic Classification and design overview
Compressors Basic Classification and design overview What are compressors? Compressors are mechanical devices that compresses gases. It is widely used in industries and has various applications How they
More informationVariable Displacement Double Pump A20VO. Series 1, for open circuits Axial piston - swashplate design, Back to back - design
Brueninghaus Hydromatik Series 1, for open circuits Axial piston - swashplate design, Back to back - design RE 93100/02.97 Sizes 60...260 Nominal Pressure up to 350 bar Peak Pressure up to 400 bar Preliminary
More informationAPPLICATION. Conveyors Metal working machines Machines for agriculture Road building machines Mining machinery Food industries
HYDRAULIC APPLICATION Conveyors Metal working machines Machines for agriculture Road building machines Mining machinery Food industries Special vehicles Plastic and rubber machinery etc. CONTENTS Specification
More informationInstallation Instructions
Installation Instructions BW Seals Uniseal Series Cartridge metal bellows single and dual seals Experience In Motion Description The Uniseal metal bellows seal series consists of: Uniseal I - Single seals
More informationSlide and Turn System SF25
Profile system Frameless all-glass slide and turn system Option of flush or weathered bottom track Optionally with lateral aluminium panel profiles to close the ventilation gap The flush bottom track is
More informationSlide and Turn System SF35
Profile system Framed slide and turn system Non-thermally insulated aluminum profiles with insulated glass Option of flush or weathered bottom track The flush bottom track is particularly suitable for
More informationSTAINLESS STEEL GRAND SERIES
STAINLE STEEL GRAND SERIES STAINLE STEEL GRAND SERIES DEEPWELL SUBMERSIBLE PUMPS STAINLE STEEL - GRAND SERIES C.R.I. Always equips itself in advance to face the exponentially growing technological challenges
More informationSeated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange
Data sheet Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange Description VF 2 VF 3 VF 2 and VF 3 valves provide a quality, cost effective solution for most water and chilled applications.
More informationSeries 42 Self-operated Regulators Differential Pressure Regulators with Type 2424/Type 2428 Actuator (closing) Type Type 42-28
Series 42 Self-operated Regulators Differential Pressure Regulators with Type 2424/Type 2428 Actuator (closing) and balanced Type 2422 Valve Type 42-24 Type 42-28 Application Differential pressure regulators
More informationFixed Displacement Motor A4FM
Fixed Displacement Motor 4FM RE 91 12/4. replaces: 3.95 and RE 91 1 for open and closed circuits Sizes 22...5 Series 1, Series 3 Nominal pressure up to bar Peak pressure up to 45 bar Index Features 1 Ordering
More informationE 441 E 451 E 461 E 641 E 700 Tank mounting Nominal flow rate up to 800 l/min
Return Filters E E E 6 E 6 E 7 Tank mounting Nominal flow rate up to 8 l/min Description Application In the return line circuits of hydraulic systems. Performance features Protectionagainst wear: By means
More informationE 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm
Return-Suction Filters E 8 E 98 Tank top mounting Connection up to G½ / - SE and SE Nominal flow rate up to 6 l/min / 8. gpm Description pplication For operation in units with hydrostatic drives, when
More informationPRODUCTS CATALOGUE 2017 / Torino - Strada Settimo 388/15 Tel (+39) /43 Fax (+39)
PRODUCTS CATALOGUE 2017 / 2018 10156 Torino - Strada Settimo 388/15 Tel (+39) 011.223.68.42 /43 Fax (+39) 011.223.67.67 info@ebarbero.com www.ebarbero.com CATALOGO INDEX PRODOTTI 2017 / 2018 Pumps for
More informationDEEP WELL SUBMERSIBLE PUMPS. An ISO 9001 & Company
C.R.I. PUMPS DEEP WELL SUBMERSIBLE PUMPS EVERGREEN SERIES - 5Hz An ISO 91 & 141 Company Submersible Pumps C.R.I. Submersible Pumps are the products of the expertise gained from over four decades of experience,
More informationMaterials : Carbon steel ASTM A216 WCB
Certificate 3.1 Size : Ends : Min Temperature : Max Temperature : DN 50 to DN 400 ( NPS 2" to 16" ) Flanges R.F. Class 150 (PN20) - 29 C + 425 C Max Pressure : 20 Bars Specifications : Removable stainless
More informationVPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10
/ ED VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES OPERATING PRINCIPLE The VPPL are variable displacement axial-piston pumps with variable swash plate, suitable for applications
More informationSubmersible Electric Pumps for drainage of clean and slightly dirty water DIWA Series
Submersible Electric Pumps for drainage of clean and slightly dirty water DIWA Series Submersible pumps for clean and slightly dirty water manufactured in AISI 304 stainless steel. Head up to 20 metres,
More information400V 50Hz. Tsurumi TRN. Submersible aerator. Auto-suction submersible aerator for communal and industrial waste water clearance and treatment.
Tsurumi TRN 400V Hz Submersible aerator Auto-suction submersible aerator for communal and industrial waste water clearance and treatment. TRN-submersible aerator The Tsurumi TRN-submersible aerator is
More informationOMS Technical Information Technical data
Technical data TECHNICAL DATA FOR OMS Type OMS OMS OMS OMS OMS OMS OMS OMS OMS OMSW OMSW OMSW OMSW OMSW OMSW OMSW OMSW OMSW OMSS OMSS OMSS OMSS OMSS OMSS OMSS OMSS OMSS Motor size 80 100 125 160 200 250
More informationE 328 E 498 Tank top mounting Connection up to G1½ and SAE 2 Nominal flow rate up to 600 l/min
Return-Suction Filters E 8 E 98 Tank top mounting Connection up to G½ and SE Nominal flow rate up to 6 l/min Description pplication For operation in units with hydrostatic drives, when the return flow
More informationINSTALLATION & MAINTENANCE INSTRUCTIONS - ORIGINAL VERSION AVK KNIFE GATE VALVES
1. INTRODUCTION The AVK knife gate valve is a unique, patented, bi-directional on-off valve that ensures a bubble-tight shut off. The valve is available with body of ductile iron and seat of nitrile, viton,
More informationUCA-UVO-UCB. SUBMERSIBLE PUMPS Lifting of polluted water Commercial use 2 pole - 50 Hz OPERATING LIMITS APPLICATIONS CHARACTERISTICS ADVANTAGES
OPERATING LIMITS Flow rates up to: 24 m 3 /h Head up to: 62 m Maximum immersion depth: 12.5 m Max. particle size: Ø 5 to 8* ND discharge port: 8/1 mm IP : 68 *depending on model SUBMERSIBLE PUMPS Lifting
More information50Hz. water solutions. O SerieS DGO DRO
Hz water solutions O SerieS DGO DRO D a t a b o o k l e t EN water solutions O SerieS DGO DRO Hz D a t a b o o k l e t O SERIES O Series General characteristics AISI stainless steel lifting and carrying
More informationE 094 E 103 E 143 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 135 l/min / 35.7 gpm
Return Filters E 9 E E Tank top mounting Connection up to G / -6 SAE Nominal flow rate up to 5 l/min / 5.7 gpm Description Application In the return line circuits of hydraulic systems. Performance features
More informationCentrifugal Pumps Gas handling combi pump in segmental design
Centrifugal umps Gas handling combi pump in segmental design UEA... TECHNICAL DATA Output: max. m³/h Differential pressure: max. bar Speed: max. rpm Temperature: - C to + C Casing pressure: N up to size
More informationCAST IRON SAFETY VALVE TYPE 6301
CHARACTERISTICS The 6301 safety valve is dedicated to protect the equipment from potential overpressure. This is an automatic device that closes when the pressure conditions are back to normal. It is a
More informationOMS Technical Information. Versions OMS. Versions
Versions Versions Mounting flange Shaft Port size European version US version Drain connection Check valve Main type designation Standard flange Cyl. 32 G 1/2 l Yes Yes Cyl. 1.25 in 7/8-14 UNF l Yes Yes
More informationMounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator
Self-operated Pressure Regulators Type 2357-31 Pressure Build-up Regulator with safety function and integrated excess pressure valve Type 2357-31 with non-return unit at port C Ports A and B with soldering
More informationDN 65 to 100 R.F. PN10 flanges + 5 C + 65 C Max Pressure : 10 Bars Specifications : Brass check valve Controlable With valves DN1/2
Size : Ends: Min Temperature : Max Temperature : DN 65 to 100 R.F. PN10 flanges + 5 C + 65 C Max Pressure : 10 Bars Specifications : Brass check valve Controlable With valves DN1/2 Materials : Bronze body
More informationSerie ECO 3T. Threaded end back flow preventer with controllable reduced pressure zone. made in. Application fields. Protection E U R O P E
Serie ECO T Threaded end back flow preventer with controllable reduced pressure zone BRANDONI made in E U R O P E Application fields WATER FIRE FIGHTING DRINKING WATER 74 www.brandoni.it Serie ECO T The
More informationLevel switches Series LD Vibrating fork level switch for liquids and solids
Level switches Series LD Vibrating fork level switch for liquids and solids Robust and compact Suitable for liquids (model LD61) and solids (model LD60) No moving parts, low maintenance Corrosion resistant
More informationVALVES HIDROMATIC VALVE.
VALVES HIDROMATIC VALVE Hydrodynamic design The Hidromatic valve of Hidroconta is a piston hydraulic valve controlled with the same fluid of the conduction. Its balloon design improves its hydrodynamic
More informationLevel switches Series LD Vibrating fork level switch for liquids and solids
Level switches Series LD Vibrating fork level switch for liquids and solids Robust and compact Suitable for liquids (model LD61) and solids (model LD60) No moving parts, low maintenance Corrosion resistant
More informationInstallation Operation Maintenance
682 Seal Cooler New generation seal cooler to meet and exceed the seal cooler requirements stated in the 4th Edition of API Standard 682 Installation Operation Maintenance Experience In Motion Description
More informationINSTRUCTIONS AND MAINTENANCE MANUAL SERIES: RT
INSTRUCTIONS AND MAINTENANCE MANUAL 05/11/2015 SERIES: RT cmo @cmo.es http://www.cmo.es page 1 ASSEMBLY THE RT VALVE COMPLIES WITH THE FOLLOWING: Machinery Directive: DIR 2006/42/EC (MACHINERY) Pressure
More informationM A B MAB INFLATABLE GASKET SLIDE VALVES SERIES TSV FOR POWDERED AND GRANULAR SOLID MATERIALS
Automatic slide valves type TSV-150 with inflatable sealing system. The range of TSV slide valves supplied by MAB can always close against a head of flowing solids. The TSV series of inflatable gasket
More informationE 084 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 80 l/min / 21.1 gpm
Return-Suction Filters E 08 Tank top mounting Connection up to G / -6 SE Nominal flow rate up to 80 l/min /. gpm Description pplication For operation in units with hydrostatic drives, when the return flow
More informationGoulds 3296 EZMAG. Chemical Process Pump
Goulds 3296 EZMAG Chemical Process Pump 3296 EZMAG Chemical Process Pump Capacities to 700 gpm (160 m3/h) Heads to 620 ft (189 m) Temperatures to 535 F (280 C) Pressures to 275 PSIG Performance Features
More informationBall Float Steam Trap UNA 45 MAX, UNA 46 MAX, UNA 46A MAX PN 40/Class 300 DN 40, 50, 65
Data Sheet 819346-02 Issue Date: 05/17 Ball Float Steam Trap UNA 45 MAX, UNA 46 MAX, UNA 46A MAX PN 40/Class 300, 50, 65 UNA 45hl MAX, UNA 46hl MAX, UNA 46Ahl MAX UNA 45v MAX with cover for mounting electrode
More informationNeotecha SAPRO - Aseptic sampling valve SV Installation, operation and maintenance instructions
Before installation these instructions must be fully read and understood 2 Safety Please read these instructions carefully. 2.1 General danger potential Not paying attention to this instruction Incautious
More informationL21S/SR/ST Glass Level Gauges
L21S/SR/ST Glass Level Gauges Doc. no.: 150, en_cat_l21s/sr/st, 12/2014 Type of code Example: L21ST/1450/AANSI 3/4 150Lb RF/Large chamber Code 1 Basic type L21 2 Type of gauge S Tubular level gauge SR
More informationPRESSURE REGULATOR LBM SERIES
VIRTUAL CATALOGUE FAIL TO OPEN REGULATOR HIGH FLOW COEFFICIENT WIDE PRESSURE-REGULATION RANGE FAST RESPONSE PRESSURE REGULATOR LBM SERIES FULL SEAL AT ZERO FLOW CAN BE SUPPLIED WITH MINIMUM / MAXIMUM PRESSURE
More information60HZ XIANDAI PUMP. CDL/CDLF Vertical Multistage Pump ZHEJIANG XIANDAI PUMP CO.,LTD. ZHEJIANG XIANDAI PUMP CO.,LTD.
TECNICAL DATA INCLUDED IN TIS BROCURE MAY BE CANGE FROM TIME TO TIME DUE TO TE PRODUCT IMPROVEMENTS UNDERTAKES BY TE MANUFACTURER. TE COMPANY RESERVES TE UNCONDITIONAL RIGTS TO IMPLEMENT SUC CANGES WITOUT
More informationT Y P E V S A B M S E W A G E P U M P
Pe r fo r m a n ce C h a r t s 11 1 D R Y P I T S B U L L E T I N 2 3 9 8 7 6 5 4 3 2 1 12 11 1 / 4 1 1 / 2 9 3 / 4 9 5% 3 HP 5 HP 7 1/2 HP 1 HP 76% 5% C u r v e P a g e V S A B M - 4 1 1 5 R P M M O D
More informationFixed Displacement Plug-In Motor A2FE
www.phphyds.com Series 6, axial tapered piston, bent axis design for mounting in mechanical gearboxes Sizes 28...355 Nom. Pressure up to 400 bar Peak Pressure up to 450 bar he fixed displacement plug-in
More informationE 158 E 198 E 248. Tank top mounting Connection up to G11 / 4 Nominal flow rate up to 250 l/min e d
R e t u r n - S u c t i o n F i l t e rs E 158 E 198 E 248 Tank top mounting Connection up to G11 / 4 Nominal flow rate up to 250 l/min 20.90-5e 0.0-2d D e s c r i p t i o n Application For operation in
More informationWastewater combination air valve in stainless steel AISI 316 Mod. SCS
Wastewater combination air valve in Mod. SCS The air valve guarantees the proper operation of sewage/industrial lines allowing the entrance of large quantity of air in case of pipe bursting or draining,
More informationSerie 06-M6. Swing wafer check valve. made in. Application fields. Check valves E U R O P E WATER CONDITIONING INDUSTRY
Swing wafer check valve BRANDONI made in E U R O P E Application fields WATER CONDITIONING INDUSTRY HEATING 38 www.brandoni.it The valves in series 06 are swing wafer check valves, manufactured in accordance
More informationLiquid ring vacuum pumps in compact design
Liquid ring vacuum pumps in compact design LEM 26, LEM 51 Pressure range: Suction volume flow: 33 to 113 mbar 3 to 58 m³/h CONSTRUCTION TYPE SIHI liquid ring vacuum pumps are displacement pumps of uncomplicated
More informationVALFONTA INSTRUCTIONS: OPERATION AND INSTALLATION PRESSURE REDUCING VALVE MODEL PRV44
INSTRUCTIONS: OPERATION AND INSTALLATION PRESSURE REDUCING VALVE MODEL PRV44 Pressure Reducing Valve PRV44 - Operation and Installation - 1 - manual PRV44-16-ENG JULY 2016 INDEX PAGE 1 IDENTIFICATION PLATE
More informationPressure Regulator B-95
Pressure Regulator B-95 TYPE B WATER & AIR TYPE B INTERIOR WATER & AIR B SERIES VALVES DESTRIPTION The Cash Valve Series B pressure reducing and regulating valves are single seated, spring loaded, direct
More informationSerie ECO 3F. Flanged back flow preventer with controllable reduced pressure zone. made in. Application fields. Protection
Flanged back flow preventer with controllable reduced pressure zone made in Application fields WATER FIRE FIGHTING DRINKING WATER 64 www.brandoni.it The ECO 3F flanged backflow preventers, which have a
More informationMaterials : Stainless steel ASTM A351 CF8M
Certificat 3.1 Size: Ends : Min Temperature : Max Temperature : DN 15 to DN 200 PN16 Flanges R.F. - 20 C + 200 C Max Pressure : 16 Bars Specifiations : Removable stainless steel filter Bolted bonnet with
More informationMUD 1. Vent check valves. Instruction and maintenance manual.
MUD 1 Vent check valves Instruction and maintenance manual. Version: 04-02-2011. 2 List of Contents 1. INTRODUCTION 3 1.1 The Problem... 3 1.2 The Solution... 3 2. RULES AND REGULATIONS 3 2.1 General requirements....
More informationInstallation Instructions
Installation Instructions TM Five Star Seal 80 Series Dual, Cartridge Mounted, Flexible Stator Pusher Seal Designed for General Service Applications 86 and 87 Experience In Motion Description The 86/87
More informationPilot operated pressure relief valve sandwich plate,type ZDB/Z2DB6 Huade América 1
Pilot operated pressure relief valve sandwich plate,type ZDB/Z2DB6 Huade América 1 BEIJING HUADE HYDRAULIC INDUSTRIAL GROUP CO.,LTD. Pilot operated pressure relief valve sandwich plate,type ZDB/Z2DB6 Size
More informationEtanorm V Type Series Booklet
Vertical Low-pressure Pump Etanorm V Type Series Booklet Legal information/copyright Type Series Booklet Etanorm V All rights reserved. The contents provided herein must neither be distributed, copied,
More information3-way control valves VK 3
Data sheet 3-way control valves VK 3 Description / Application VK 3 valves are a range of 3 port high specification flanged valves for chilled water, LPHW, MPHW, HPHW (low, medium or high pressure hot
More informationE 212 E 222 Tank top mounting Connection up to G1¼ / -20 SAE Nominal flow rate up to 220 l/min / 58.1 gpm
Return Filters E E Tank top mounting Connection up to G¼ / - SE up to l/min / 8. gpm Description pplication In the return line circuits of hydraulic systems. erformance features rotection against wear:
More informationLiquid ring vacuum pumps single-stage
Liquid ring vacuum pumps single-stage LPH 40106, LPH 40411, LPH 40516 Pressure range: Suction volume flow: 150 to 1013 mbar 50 to 270 m³/h CONSTRUCTION TYPE Sterling SIHI liquid ring vacuum pumps are displacement
More informationComponents for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.
Components preparation and pressure adjustment ABP Overview ABP is a component that enables boosting by s only up to twice primary pressure (.0MPa max.) in combination with using air tank but not using
More informationTP1 and TP2 Temporary Cone Shaped Strainers
1698051/2 IM-P169-07 ST Issue 2 TP1 and TP2 Temporary Cone Shaped Strainers Installation and Maintenance Instructions TP1 1. Safety information 2. General product information 3. Installation and commissioning
More informationMODEL 200 KNIFE GATE VALVES INSTALLATION & MAINTENANCE MANUAL
MODEL 200 KNIFE GATE VALVES INSTALLATION & MAINTENANCE MANUAL Index 1. List of components / General arrangement 2. Description 3. Handling 4. Installation 5. Actuators / Operation 6. Maintenance a. Changing
More informationInstallation, Operating and Maintenance Manual Overflow Regulator Type 94/ 94 E
Installation, Operating and Maintenance Manual Overflow Regulator Type 94/ 94 E Table of content 1. General information on installation, operating and maintenance instructions 1.1 Hazard notices 1.2 Qualified
More informationTarget disk flowmeter Series DP. Instructions manual DP65 DP500. R-MI-DP Rev.: 4 English version
Target disk flowmeter Series DP Instructions manual DP65 DP500 R-MI-DP Rev.: 4 English version PREFACE Thank you for choosing the flowmeter series DP from Tecfluid S.A. This instruction manual allows the
More informationSCA Series Inverted Bucket Steam Traps
0770050/5 IM-P077-06 ST Issue 5 SCA Series Inverted Bucket Steam Traps Installation and Maintenance Instructions 1. General safety information 2. General product information 3. Installation 4. Commissioning
More informationOsborne Engineering Limited. OEJ Equalised thrust bearing internals
Osborne Engineering Limited OEJ Equalised thrust bearing internals General Description The Osborne Equalised J style thrust bearing assembly operates by generating and maintaining a substantial oil film
More informationSize : Ends : Min Temperature : Max Temperature : Materials : Cast iron body
Size : Ends : Min Temperature : Max Temperature : DN 40 to DN 300 Flanges R.F. PN10/16-10 C + 80 C Max Pressure : 16 Bars up to DN200 Specifications : Removable stainless steel filter Bolted bonnet with
More informationSi C132. Safety valves for pressure relief in accordance to PED, DIN/EN and ASME. Engineering GREAT Solutions
Safety valves for pressure relief in accordance to PED, DIN/EN and ASME Engineering GREAT Solutions Si C132 Features The universal compact safety valve > 3 body seat sizes for appropriate size selection
More informationMechanical Pressure Measurement
Mechanical Pressure Measurement Differential Pressure Gauges Model GDP, Universal Version, with Diaphragm Element High Overpressure Safety PN 40, 100, 250 or 400 Applications Differential pressure measurement
More informationINDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES
INSTRUCTION MANUAL Installation Operation Parts Service IMPORTANT Record your Regulator model number and serial number here for easy reference: Model No. Serial No. Date of Purchase When ordering parts
More informationTB1, TB1F and TB2 ready-fitted mechanical seals for AHLSTAR pumps
TB1, TB1F and TB2 ready-fitted mechanical seals for AHLSTAR pumps Simple and robust design maximize reliability in operation 1 TB1, TB1F and TB2 ready-fitted mechanical seals are designed for the seal
More informationInstructions. Control Solution ICF 20-4, ICF 25-4, ICF ICF 40-4, ICF 20-6, ICF 25-6, ICF 32-6, ICF 40-6, Direction and position.
027R9782 Instructions Control Solution ICF 20-4, ICF 25-4, ICF 32-4. ICF 40-4, ICF 20-6, ICF 25-6, ICF 32-6, ICF 40-6, Direction and position ICF xx-4 ICF xx-6 ICF xx-4 / ICF xx-6 with ICM ICM 027R9782
More informationHigh Performance BSP Dial Up Pattern Pressure Reducing Valve
See our full range online at: www.vip-ltd.co.uk High Performance BSP Dial Up Pattern Pressure Reducing Valve VIP Product Code 31/0103 FUNCTION Pressure reducing valves are devices which, when installed
More information12 Impeller Replacement
144 Impeller Replacement INTRODUCTION Jabsco The Original Impeller Jabsco Flexible Impellers can be fitted to most makes and models of bronze flexible impeller engine cooling, bilge, transfer and general
More informationNew! ProFlow. Sliding Vane Meters DN (½ - 2 ) _ 142. Product Bulletin
New! ProFlow Sliding Vane Meters DN 15-5 (½ - 2 ) _ 142 Product Bulletin WWW.VAF.NL 1 Introduction VAF Instruments ProFlow positive displacement sliding vane type liquid flowmeters are used in continuous
More informationKLINGER CONAXE Double Offset High Performance Butterfly Valve DN
KLINGER CONAXE Double Offset High Performance Butterfly Valve DN 50-1300 www.klinger.kfc.at MF 01 KLINGER FLUID CONTROL Today for tomorrow As a subsidiary of the KLINGER Group, KLINGER Fluid Control has
More informationHEAVY DUTY KNIFE GATE VALVE
HEAVY DUTY KNIFE GATE VALVE The (SER.22) model knife gate is a bi-directional lug type valve designed according to MSS-SP-81 and TAPPI TIS 405-8 for industrial service applications. The completely new
More information2-Port Seat Valves with Flange, PN 16
4 45 2-Port Seat Valves with Flange, PN 6 VVF45... dular cast iron EN-GJS-400-5 valve body DN 50...50 k vs 9...00 m /h Can be equipped with SKB...- or SKC...- electrohydraulic actuators Use For use in
More informationDual displacement motor A10VM Plug-in dual displacement motor A10VE for open and closed circuit applications
Replaces: 04.95 Dual displacement motor 10VM Plug-in dual displacement motor 10VE for open and closed circuit applications Size 28-60 Series 5 Nominal pressure 280 bar Peak pressure 350 bar 10VM Contents
More informationDEH Instructions. Three-Phase, Platform-Mounted Distribution Transformers
g DEH 40050 Instructions Three-Phase, Platform-Mounted Distribution Transformers Introduction The equipment covered by these instructions should be operated and serviced only by competent technicians familiar
More informationFixed Displacement Motor A4FM
Industrial Hydraulics Electric Drives and Controls Linear Motion and ssembly echnologies Pneumatics Service utomation Mobile Hydraulics Fixed Displacement Motor 4FM RE 91 12/4. replaces: 3.95 and RE 91
More information3800 SERIES END SUCTION PUMP REPAIR PARTS INDEX. Model Model 3804
Model 3801 Model 3804 3800 SERIES END SUCTION PUMP REPAIR PARTS INDEX NOTE! To the installer: Please make sure you provide this manual to the owner of the equip ment or to the responsible party who maintains
More informationInstallation Instructions
Installation Instructions Durametallic SLM-6000, SLM-6100 Self contained cartridge medium duty slurry seal Experience In Motion 1 Cartridge Installation Instructions The following instruction manual is
More informationHand pump type CH. Product documentation. 300 bar 8.3 cm 3 /stroke. Operating pressure p max : Displacement volume V max stroke :
Hand pump type CH Product documentation Operating pressure p max : Displacement volume V max stroke : 300 bar 8.3 cm 3 /stroke D 7147 CH 04-2018-1.1 by HAWE Hydraulik SE. The reproduction and distribution
More informationAuxiliary valve QDS6 Sequence valve, 3-way. Catalogue (GB) (US) October 1998
Auxiliary valve Sequence valve, 3-way Catalogue 9129 8542-02 (GB) 9129 8542-06 (US) October 1998 Sequence valve, 3-way Applications The sequence valve is designed to open or close a hydraulic pilot signal
More informationGROUTEC SCOTT VICKERS. Grouting Equipment
GROUTEC SCOTT VICKERS Grouting Equipment SCOTT VICKERS manufacturers a range of cement and chemical grouting equipment including:- PUMPS - The Cement Grout Pumps are all diaphragm-type. These diaphragms,
More information