General Specifications
|
|
- Hugh Harper
- 5 years ago
- Views:
Transcription
1 General Specifications DOG Optical Dissolved Oxygen Sensor GENERA DOG optical dissolved oxygen sensor is designed for using in water treatment plants such as sewage treatment works and effl uent activated sludge process. This optical sensor has a fast response time and good long term stability, and features replaceable sensor cap and cable for easy maintenance. A temperature sensor is incorporated for compensation. The DOG sensor can be used in either the PB350G/PB360G fl oating ball holder or in the DOX8HS submersion type holder. DOG Optical Dissolved Oxygen Sensor FEATURES DO Sensor with ong-term Stability and Short Stabilization Time A Optical DO sensor that uses a phase measurement method and realizing stable measurements over a long period of time. Measuring range of 0 to 25 mg/l. A sensor cap that is easily replaceable by anyone. SYSTEM DO402G Dissolved Oxygen onverter Refer to GS 12J05D02-00E for DO402G dissolved oxygen converter and GS 12J E for Holders AUTION Installation ocation of Holders (Submersion Type, etc) The holder should be used in a place that is as vibration free as possible. Using the holder in a place where it is affected by vibration, may result in damage to the holder. Yokogawa Electric orporation , Nakacho, Musashino-shi, Tokyo, Japan Tel.: Fax.: opyright Jan 2012 (YK)
2 GENERA SPEIFIATIONS Dissolved Oxygen: 0 to 25 mg/l (ppm) iquid Temperature: 0 to 50 iquid Pressure: 0 to 500 kpa Sensor for Temperature ompensation: 22k NT Material: Body; SUS316 O-ring; Ethylene Propylene Rubber (EPDM) able clothing; Heat-resistant soft polyvinyl chloride able ength: 3 m, 5 m, 10 m Weight: Sensor; Approx. 0.1 kg able 3 m; Approx. 0.4 kg 5 m; Approx. 0.6 kg 10 m; Approx. 1.1 kg HARATERISTIS Repeatability: 0.1 mg/l or 3% FS, whichever is greater Temperature ompensation Error: Within ±3% FS for a ±5 change in the range of 0 to 40 Response Time: Within 120 sec. (90% response) GENERA SPEIFIATIONS OTHERS DOX10 Power Supply Unit Used for supplying power to DOG. Ambient temperature: -10 to 55 onstruction: JIS waterproof (IP53) ase material: Fiberglass reinforced polycarbonate resin Electrical connections: Watertight plastic gland with cable. (applicable cable O.D.: Ø6 ~ Ø12) onduit adaptor (optional available) ase color: Grayish green (Munsell 2.5GY5.0/1.0) Power supply: 100/115/230V A 50/60Hz Acceptable range: Rated voltage ±15% Output voltage: 24V D ±1V Weight: Body; Approx. 1.6 kg Mounting bracket: Approx. 0.7 kg Attached cable: Approx. 0.3 kg DOX8W alibration Set (optional) This is necessary if the span calibration is to be done using a saturated dissolved oxygen solution. <ontents> Air pump, stirrer, stirring element, bubbler, clamp, beaker, and thermometer. Note: The calibration set can be used in common regardless of the type of holder. MODE AND SUFFIX ODES 1. Optical Dissolved Oxygen Sensor Model DOG Insert length Type able length Suffix ode E -00N -03E -05E -10E ode -N Adaptor /S3 Tag plate /PP /FPP /ST Optical dissolved oxygen sensor 120 mm Always -E No cable 3m (*1) 5m (*1) 10m (*1) Description 2 Always -N Submersion type holder (stainless steel) Submersion type holder (polypropylene) Froat holder (polypropylene) Stainless steel tag plate *1: The power cable is +1.5m. (Refer to DIMENSION ) 2. Power Supply Unit Model DOX10 Power supply -U able length Suffix ode Mounting bracket Tag plate onduit work adaptor 3. alibration Set Model DOX8W Style * A 4. Spare Parts Part Name Sensor cap ode Description Power supply unit -N Always -N Suffix ode Part No. K 9679AN /P /W /ST /B1 /D1 /F1 ode Always -U No cable 1.5m (DO402G power supply use) Pipe mounting bracket Wall mounting bracket Stainless steel tag plate G1/2, 1pcs 1/2 NPT, 1pcs M20 x 1.5, 1pcs Description alibration set Style * A Remarks Please shade the light during safe keeping. Zero adjusting reagent 9920BR Sodium sulfite 500g Adaptor K9148NA For submersion type holder (stainless steel) K9148NB For submersion type holder (polypropylene) K9679A For float type holder (polypropylene) Sensor cable K9679BA K9679BB K9679B 3 m 5 m 10 m T02.ai T03.ai
3 <<ontents>> <<Index>> DIMENSION DOG Optical dissolved Oxygen Sensor 3 Unit:mm 0 Ø Ø ± Model-Suffix code Weight (kg) DOG E - 00N - N No cable Approx. 0.1 DOG E - 03E - N 3,000 Approx. 0.5 DOG E - 05E - N 5,000 Approx. 0.7 DOG E - 10E - N Approx. 1.2 Adaptor (/S3, /PP) Adaptor (/FPP) Weight /S3 : Approx.173 /PP : Approx. 20 DOX10 Power Supply Unit M5 (10mm) () Detailed drawing of cable for power supply unit ±0.2 a G1/2 female /B1 Adaptor for onduit 1/2NPT female /D1 M (F1) 76 ± b F15.EPS
4 4 Attached able with DOX10 (Not supplied if suffix code -00-N is selected) Unit: mm Black White N Red G N G 30 Black N White N able length :1.5 m G Red G 80 Model and Suffix ode DOX10 - U N DOX10 - U N No cable Approx. 1,500 Weight Approx. 0.3kg (1,500 mm) Pipe Mounting Bracket for Power Supply Unit (al) ( ode: /P) 4-M5 screw Weight: 0.7 kg holes 200± hole Pipe mounting hardware holes Pipi mounting hardware 2 2-9±0.5 holes M8 nut 2 U-bolt holes Nominal 50A (O.D pipe)
5 5 Wall Mounting Bracket for Power Supply Unit (al) ( ode: /W) Weight: 0.7 kg 4-M hole ±0.5 4-M WIRING DIAGRAM EXAMPE Output signasl 4 to 20mA D or 0 to 20mA D Output signal 4 to 20mA D or 0 to 20mA D Remote contact input leaning start DO402G ma1 N G ma2 S1 S Power supply ontact signal S1 ontact signal S2 High and ow alarms and HOD White Green Green/Yellow lear Red S3 S ontact signal S3 leaning HOD or High and ow alarms ontact signal S4/FAI Failure or High and ow alarms DOG Optical dissolved oxygen sensor Note : External wiring connection terminal size is for Ø2 pin. Grounding terminal 2 M4 screw Protective grounding (100 or less *1: Always use a shielded cable with an OD of 6 to 12 mm. *2: e sure to ground the DO converter case grounding terminal (grounding resistance of 100 or less. *3: Always use a cable with an OD of 6 to 12 mm. Brown Blue DOX10 Poewr supply unit N N Power supply G G (BN (B F11.eps
6 6 Inquiry Specifications Sheet for Optical Dissolved Oxygen Sensor For inquiry on the Yokogawa optical dissolved oxygen sensor, please tick ( ) the appropriate box ( ) and fi ll up the relevant information in the blanks. 1. General Name of your company: Name of inquirer : Dept. or sect : (Telephone; ) Name of plant : Measuring point : Purpose of use : Indication Recording Alarm ontrol Power supply : V A 2. Measurement onditions (1) iquid temperature : to, normal [ ] (2) iquid pressure : to, normal [kpa] (3) Flow rate : to, normal [m/s] (4) Name of liquid to be measured : (5) omponents of liquid to be measured : (6) Other conditions : 3. Installation environment (1) Ambient temperature: (2) ocation : Outdoors Indoors (3) Other information : 4. Requirements (1) Measurement range : 0 to 25 mg/l (2) System component selection: Sensor onverter Power supply unit Holder leaning system alibration set (3) ength of sensor cable : 3 m 5 m 10 m (4) Type of holder : Submersion Floating ball (5) leaning method : No cleaning Jet cleaning (6) Other requirements : Subject to change without notice.
Model DO70G Optical Dissolved Oxygen Sensor
User s Manual Model DO70G Optical Dissolved Oxygen Sensor TM 3rd Edition u Introduction The DO70G optical dissolved oxygen sensor uses the optical (fluorescence) measurement method to continuously measure
More informationGeneral Specifications
General Specifications GS 0131Y01-01EN EJA60E Hygienic Adapter System (Fluidless Type) EJA560E Hygienic Gauge Pressure Transmitter (Fluidless Type) EJA60E Hygienic Adapter System (Fluidless Type) consist
More informationGeneral Specifications
General Specifications GS 0131Y01-01EN EJA60E Hygienic Adapter System (Fluidless Type) EJA560E Hygienic Gauge Pressure Transmitter (Fluidless Type) [Style: S2] EJA60E Hygienic Adapter System (Fluidless
More informationGeneral Specifications
General Specifications Model DO202G 2-wire Dissolved Oxygen Transmitter Flexibility, reliability and low maintenance are among the benefits provided by the EXA DO202 2-wire Dissolved Oxygen transmitter.
More informationExpert Hydrostatic Level Transmitters
Expert Hydrostatic s General Features MJK Expert hydrostatic level transmitters are designed for level measurement by submerging the transmitter in open channels, drains and tanks. Expert hydrostatic level
More informationDissolved Oxygen Converter
User s Manual Model DO402G [Style: S3] Dissolved Oxygen Converter 8th Edition PREFACE WARNING Electric discharge The EXA analyzer contains devices that can be damaged by electrostatic discharge. When
More informationHigh-performance submersible pressure transmitter For level measurement Model LH-20
Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-20 WIKA data sheet PE 81.56 Applications Deep well and borehole measurements Groundwater
More informationHigh-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20
Electronic pressure measurement High-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20 WIKA data sheet PE 81.56 Applications Deep well and borehole measurements
More informationHigh-performance submersible pressure transmitter For level measurement Model LH-10
Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-10 WIKA data sheet PE 81.09 Applications Level measurement in rivers and lakes Deep well
More informationHigh-performance submersible pressure transmitter For level measurement Model LH-20
Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-20 WIKA data sheet PE 81.56 Applications Deep well and borehole measurements Groundwater
More informationHigh-performance submersible pressure transmitter For level measurement Model LH-10
Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-10 WIKA data sheet PE 81.09 Applications Level measurement in rivers and lakes Deep well
More information9408 Series Dissolved Oxygen Systems. Dissolved oxygen systems designed for reliable operation with minimal operating costs
Data sheet DS/9408 EN Rev. M 9408 Series Dissolved oxygen systems designed for reliable operation with minimal operating costs Reduced sensor fouling design minimizes operational costs Low maintenance,
More informationABB MEASUREMENT & ANALYTICS DATA SHEET series Dissolved oxygen systems
ABB MEASUREMENT & ANALYTICS DATA SHEET 9408 series Dissolved oxygen systems Measurement made easy Dissolved oxygen systems designed for reliable operation with minimal operating costs Reduced sensor fouling
More informationOxymax W COS41. Technical Information. Potentiostatic amperometric two-electrode sensor Long-term stable sensor for water and wastewater applications
Technical Information Oxymax W COS41 Potentiostatic amperometric two-electrode sensor Long-term stable sensor for water and wastewater applications Application The continuous measurement of the dissolved
More informationLMP 307. Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % / 0.
LMP 07 Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % / 0. % FSO Nominal pressure from 0... mho up to 0... 50 mho Output signals -wire: 4... 0 ma -wire: 0...
More informationGeneral Specifications
General Specifications YVP110 Advanced Valve Positioner GS 21B04C01-01E FEATURES Model YVP110 FOUNDATION fieldbus TM Valve Positioner accepts digital communication to control a pneumatic actuator mounted
More informationJUMO dtrans p30 Pressure Transmitter
609 Fulda, Germany Postal address: 605 Fulda, Germany Phone: +49 661 600-0 Fax: +49 661 600-607 Phone: +44 179 6 55 Data Sheet 40466 Page 1/6 JUMO dtrans p0 Pressure Transmitter General application Pressure
More informationHigh-performance submersible pressure transmitter For level measurement Model LH-20
Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-20 WIKA data sheet PE 81.56 Applications Deep well and borehole measurements Groundwater
More informationPressure Transmitters 36 F-27839
Pressure Transmitters 36 F-27839 SPD310/SPD360 Air Differential schneider-electric.com 37 SPD310/SPD360 SPD310/SPD360 differential pressure transmitters are intended for use in air handling systems for
More informationTEK-SUB 4800B. Submersible Level Transmitter. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys LEVEL
Technology Solutions TEK-SUB 4800B Submersible Level Transmitter LEVEL Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction The Tek-Sub 4800B Submersible Level Transmitter
More informationPressure Measurement Single-range transmitters for general applications
Siemens AG 07 Overview Function U const. p U I EM Sensor Connection for auxiliary power supply Vent pipe with humidity filter Protective conductor connection/ Equipotential bonding Diaphragm The pressure
More information1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI
Siemens AG 06 SITRANS LH00 Transmitter for hydrostatic level Overview Function U const. p U I EM The pressure transmitter SITRANS LH00 is a submersible sensor for hydrostatic level measurement. The pressure
More information1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI US Edition
Siemens AG 07 SITRANS LH00 Transmitter for hydrostatic level Overview Function U const. p U I EM The pressure transmitter SITRANS LH00 is a submersible sensor for hydrostatic level measurement. The pressure
More informationC-Flow Coriolis Mass Flow Meters
Coriolis Mass Flow Meters Ready for Take Off The New Compact C-Flow Küppers Elektromechanik GmbH The C-Flow The C-Flow Coriolis Mass Meters consist of two components: KCE Transmitter KCM Transducer 2 KEM
More informationTechnical Information
Technical Information Conductivity nalyzer Selection Guide Conductivity / Resistivity nalyzers Model SC4J Model SC8SG Model SC10G dapter Mounting Flow-through Model SC450G Four-wire Conductivity Model
More informationInfrared Linescanners
Thermal Imaging and Temperature Profiles for Continuous Process Monitoring and Quality Control HD Infrared Linescanners PROCESS & ANALYTICAL INSTRUMENTS Mountings and Accessories LSPHD Mountings and Accessories
More informationThin pressure gauge. G401-W Series. Symbol Descriptions. A Connection A A. B Pressure display [MPa] P04 0 to 0.4MPa P10 0 to 1.
Thin pressure gauge G401-W Series Thin, compact design ideal for incorporating devices. Suitable for filter regulator, regulator, and pressure switch (P4000-W). onnection: O ring seal, set screw G401-W
More informationOPTIBAR P 1010 C Technical Datasheet
Technical Datasheet Pressure transmitter with recessed diaphragm for general applications Wide variety thanks to modular design Measuring ranges up to 250 bar / 3750 psi High overload and temperature stability
More informationBI-680 Online Dissolved Oxygen Controller Instruction Manual
BI-680 Online Dissolved Oxygen Controller Instruction Manual BANTE INSTRUMENTS CO., LTD BI-680 Online Dissolved Oxygen Controller 1 Introduction Thank you for selecting the BI-680 online dissolved oxygen
More informationFLAMMABLE GAS SENSOR/TRANSMITTER
FLAMMABLE GAS SENSOR/TRANSMITTER Plant safety protection for flammable gases. F E A T U R E S Fixed gas monitoring for point source hazards and perimeter protection in arduous duty and exposed locations.
More informationSPD310/SPD360 Air Differential
SPD310/SPD360 Air Differential Pressure SPD310 / SPD360 SPD310 / SPD360 differential pressure transmitters are intended for use in air handling systems for the monitoring of air ducts, filters and fans.
More informationALL-IN-ONE MINI THERMAL MASS FLOWMETER
INDICATION, TOTAIZATION, -POINT AARM, DC to ma AND PUSE OUTPUT BY ONE UNIT TF-T Series A-IN-ONE MINI TERMA MASS FOWMETER OUTINE TF-T MINI TERMA MASS FOWMETER is for the measurement of mass flow rate of
More information9408 series Dissolved oxygen systems
ABB MEASUREMENT & ANALYTICS INSTRUCTION MANUAL IM/908 REV. K 908 series Dissolved oxygen systems Measurement made easy 908 series Dissolved oxygen systems Introduction The 908 Series dissolved oxygen system
More informationDPS-400 SERIES DPH-100 SERIES
745 Dual Display Digital Pressure Sensor For Gas DPS-400 SERIES SERIES General terms and conditions... F- guide... P.699~ Related Information Glossary of terms... P.156~ General precautions... P.1566 PHOTO
More informationJUMO dtrans O2 01 Two-wire Transmitter for dissolved oxygen (DO)
Data Sheet 202610 Page 1/12 JUMO dtrans O2 01 Two-wire Transmitter for dissolved oxygen (DO) with optional terminal box or operating unit Type 202610 Two-wire transmitter JUMO dtrans O2 01 Brief description
More informationph measuring system for hygienic process applications
ph measuring system for hygienic process applications Sterile design, CIP-compatible, in-line sterilizable Extremely robust and unbreakable construction Extremely long service life Long calibration intervals
More informationINSTRUCTION MANUAL Pressure Relief Device LPT
INSTRUCTION MANUAL Pressure Relief Device LPT 5COV475800 LPT REV00 CONTENT: 1 SAFETY 1.1 Safety instructions 2 1.2 Specified applications 2 1.3 Safety notes on the equipment operation 2 2 PRESSURE RELIEF
More informationCALEFFI. Ball zone valves. series /03 GB
all zone valves series cert. n ISO / Function Zone valves are used to automatically shut-off the flow of carrier fluid distributed to a system. Specifically: -In central heating systems, they support the
More informationInstallation, operating and maintenance Instructions for Seemag bypass level indicator
Issue: S Date: 05-09-14 Type G35 General information The Seetru bypass magnetic level indicator, abbreviate SEEMAG, serves to show the filling level of fluids in tanks, basins, tubes etc. The Seemag operates
More informationUltrasonic level transmitter and indicator
Ultrasonic level transmitter and indicator No contact with the product Compact design with polycarbonate housing (electronics and display). Remote display available on request Very good resistance in corrosive
More informationDifferential Pressure Transmiter
Differential Pressure Transmiter Description The is an economical alternative to established differential pressure transmitters. It combines state of the art electronics and a high performance sensor;
More informationElectropneumatic Positioner and Pneumatic Positioner Type 3760 JIS
Electropneumatic Positioner and Pneumatic Positioner Type 3760 Application Single-acting positioners for direct attachment to pneumatic control valves. Supplied with an electric input signal of 4 to 20
More informationGeneral Specifications
General Specifications YVP110 Advanced Valve Positioner GS 21B04C01-01E FEATURES Model YVP110 FOUNDATION fieldbus TM Valve Positioner accepts digital communication to control a pneumatic actuator mounted
More informationOptical Dissolved Oxygen Meter
Optical Dissolved Oxygen Meter HI764113 Rugged Optical Dissolved Oxygen Probe for Fresh and Saltwater Applications Digital, weighted probe No membranes No electrolytes No oxygen consumption No flow dependence
More informationElectronic gas volume corrector model DGVC-04
Electronic gas volume corrector model DGVC-04 1. Introduction The following user s manual gives information about the installation, configuration, usage and storage of the electronic gas volume corrector
More informationMJK Expert 700 / 800 / 900 / 7070 / 7060 MJK Expert 1400 / 3400
MJK Expert 700 / 800 / 900 / 7070 / 7060 MJK Expert 1400 / 3400 Submersible Hydrostatic s Rugged and versatile 2.75 GB 2.75 Expert 090311 We reserve the right to continuously improve our products and make
More informationDissolved Oxygen Sensor
Instruction Manual 499ADO and 499ADO-VP LIQ_MAN_ABR_499ADO May 2014 Dissolved Oxygen Sensor CAUTION For additional information, please visit our website at www.rosemountanalytical.com SENSOR/PROCESS APPLICATION
More informationATM.1ST. Pressure transmitters CUSTOMER BENEFITS
Pressure transmitters ATM.1ST CUSTOMER BENEFITS High precision pressure sensor over the whole temperature range Electronic compensation Modular sensor structure (any process and electrical connections
More information9700 Transmitter Submersible hydrostatic level transmitter
Specification sheet IP0078 October 2007 Level 9700 Transmitter Submersible hydrostatic level transmitter Description The 9700 series hydrostatic level transmitter is designed to perform in the most arduous
More informationABB MEASUREMENT & ANALYTICS DATA SHEET. AP100 ph/redox (ORP) cartridge sensors with water-wash option
ABB MEASUREMENT & ANALYTICS DATA SHEET AP100 ph/redox (ORP) cartridge sensors with water-wash option 2 AP100 P H / R EDOX ( ORP ) CART RI D GE SE NSORS WITH WATE R-WASH OPTION DS/AP100-E N RE V. K Measurement
More informationBante810 Benchtop Dissolved Oxygen Meter Instruction Manual
Bante810 Benchtop Dissolved Oxygen Meter Instruction Manual BANTE INSTRUMENTS CO., LTD Bante810 Benchtop Dissolved Oxygen Meter 1 Introduction Thank you for selecting the Bante810 benchtop dissolved oxygen
More informationOSAT Series. Intrinsically Safe Infrared Temperature Sensor Operator's Guide
OSAT Series Intrinsically Safe Infrared Temperature Sensor Operator's Guide Issue L Jan 2017 Introduction OSAT Series intrinsically safe non-contact infrared temperature sensors measure the temperature
More informationMPM280 Piezoresistive OEM Pressure Sensor
MPM280 Piezoresistive OEM Pressure Sensor MPM280 Pressure Sensor (V1.2) Features Pressure range 0kPa~20kPa 70MPa; Gauge, absolute and sealed gauge; Constant current / Constant Voltages power supply; Isolated
More informationElectropneumatic Positioner and Pneumatic Positioner Type 3760 JIS
Electropneumatic Positioner and Pneumatic Positioner Type 3760 Application Single-acting positioners for direct attachment to pneumatic control valves. An electric standardized signal of 4 to 20 ma or
More informationLevel transmitters and indicators Series LU Ultrasonic level transmitter and indicator for liquids and solids
Level transmitters and indicators Series LU Ultrasonic level transmitter and indicator for liquids and solids No contact with the product Compact design with polycarbonate housing (electronics and display).
More informationELADOS EDP L Diaphragm Metering Pump Type
ELADOS EDP L Diaphragm Metering Pump Type 04800-06700 Motor-driven diaphragm pump with integrated frequency converter High reserves due to a powerful asynchronous motor High flexibility due to variably
More informationPressure transmitter PASCAL Ci4
Pressure transmitter PASCAL Ci4 for general application,type Series CI4100 Features Pressure transmitter for the measuring of relative and absolute pressures of gases, vapors and liquids High-resolution
More informationIntegral type Differential pressure flowmeter VNT Series
Integral type Differential pressure flowmeter VNT Series OUTLINE VH series Wafer-Cone differential pressure flowmeter and high precision differential pressure transmitter are integrated into one flowmeter.
More informationSITRANS P measuring instruments for pressure
SITRANS P measuring instruments for pressure Z series for gage pressure Siemens AG 008 Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and
More informationGas density monitor With integrated transmitter Model GDM-100-TI
SF 6 gas solutions Gas density monitor With integrated transmitter Model GDM-100-TI grid Products WIKA data sheet SP 60.05 for further approvals see page 5 Applications Gas density monitoring of closed
More informationProgrammable pressure and temperature transmitters PTM/RS485
Programmable pressure and temperature transmitters PTM/RS485 Version: 26.06.2014 Technical Specifications Pressure measuring range (bar) 0.1... 0.5 > 0.5 2 > 2 25 Overpressure 3 bar 3 x FS ( 3 bar) 3 x
More informationT02.0.3X.6C-06 Page 1 of 6. Operating Manual for Dissolved Oxygen-Measuring transducer OXY 3610 MP
T02.0.3X.6C-06 Page 1 of 6 Specification: Measuring range: Operating Manual for Dissolved Oxygen-Measuring transducer OXY 3610 MP 0.00.. 25.00 mg/l dissolved oxygen Output signal: refer to type plate Accuracy:
More information2/2-Way Proportional Valve (motor-driven)
2/2-Way Proportional Valve (motor-driven) Type 3280 can be combined with Seat valve with stepper motor - actuator isolated from flow path Excellent range (1:100) Low power consumption Fast response Orifice
More informationMPM280 Piezoresistive OEM Pressure Sensor
MPM280 Piezoresistive OEM Pressure Sensor MPM280 Pressure Sensor (V2.0) Features Pressure range 0kPa~20kPa 100MPa; Gauge, absolute and sealed gauge; Constant current / Constant Voltages power supply; Isolated
More informationCOM280. Technical Information. Oxygen measurement Battery-driven pocket meter for dissolved oxygen measurement
Technical Information COM280 Oxygen measurement Battery-driven pocket meter for dissolved oxygen measurement Application COM280 is a pocket meter for measuring dissolved oxygen. It is suitable for the
More informationNivuBar Plus II
NivuBar Plus II Ceramic diaphragm Capacitive measuring cell 2-wire technology (output 4-20 ma) Integrated overload protection Extensive, almost front flush diaphragm Ex approval for zone 0 as standard
More informationOxymax H COS21. Technical Information. Sensor with long-term stability for frequent sterilization and autoclaving
Technical Information Oxymax H COS21 Sensor with long-term stability for frequent sterilization and autoclaving Application Process control in enzyme production Control of culture growth Biotechnological
More informationOxymax COS61/COS61D. Technical Information
Technical Information Oxymax / Dissolved oxygen measurement Optical sensor acc. to the fluorescence quenching principle, with or without Memosens protocol Application The continuous measurement of the
More informationdtrans O2 01 Two-wire Transmitter for dissolved oxygen (DO)
JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 e-mail: mail@jumo.net Internet: www.jumo.net
More informationPremium Series. Economical Price & Reliable Performance. High Quality. Rust-Resistant. Long Life. Tamper-Resistant locking Screw.
Premium Series High Quality Forged Brass Body Rust-Resistant Nickel Plated Finish Long Life Corrosion Resistant Valve Seat Economical Price & Reliable Performance Tamper-Resistant locking Screw Reduces
More information2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure
Z series for gage pressure Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and electronics plate Process connection Electrical connection
More informationZIRCONIA OXYGEN ANALYZER CONVERTER
Instruction Manual ZIRCONIA OXYGEN ANALYZER CONVERTER TYPE: ZRY OXYGEN ANALYZER Vol% O2 PREFACE We are grateful for your purchase of Fuji Zirconia Oxygen Analyzer Converter (ZRY). First read this instruction
More informationProgrammable pressure and temperature transmitters PTM/RS485
Programmable pressure and temperature transmitters PTM/RS485 Version: 03-28-2012 Technical Specifications Pressure measuring range (bar) 0.1... 0.5 > 0.5 2 > 2 25 Overpressure 3 bar 3 x FS ( 3 bar) 3 x
More informationALF400 to 900, ALT-5/-9
uto Feed Lube, uto Feed Tank LF00 to 900, -/-9 Standard Specifications uto feed lube uto feed tank LF00 LF00-0 LF00 LF00 LF00 LF900 - --IS- -9 IR : OIL : Fluid Proof pressure ir. MPa Max. operating pressure
More informationTechnical Datasheet. D Series SMART Pressure Transmitter Model: DPC D-Series. Key Features. Series Overview. Product applications
Technical Datasheet D Series SMART Pressure Transmitter Model: DPC-2000 Key Features ATEX - Flameproof and Intrinsically Safe IECEx - Flameproof and Intrinsically Safe SIL 2 certificate Compliant to NAMUR
More informationElectronic relative and differential pressure switch type 616
Electronic relative and differential pressure switch type 616 Pressure range 0... 0.1 25 bar The switching points of the pressure switch type 616 can be potentiometer adjusted by the customer, or set in
More informationCable entries. Contents. Cable entries. Cable entries Introduction C.2 C.1. Standard cable glands - Plastic C.6. Standard cable glands - Brass C.
ontents able entries able entries able entries Introduction.2 Standard cable glands - Plastic.6 Standard cable glands - Brass.9 EM cable glands.15 Standard cable glands - Stainless steel.17 able glands
More informationMobrey 9700 Transmitter Submersible Hydrostatic Level Transmitters
Product Data Sheet Mobrey 9700 Transmitter Mobrey 9700 Transmitter Submersible Hydrostatic Level Transmitters Hydrostatic electronic level transmitters Factory sealed and tested for submersed duty 4 20
More informationD-Opto Dissolved Oxygen Sensor Operation Manual for the D-Opto 4-20mA
D-Opto Dissolved Oxygen Sensor Operation Manual for the D-Opto 4-20mA Software version 2.6 Table of contents 1 Introduction...3 1.1 Optical Sensor Technology...3 1.2 Installation...4 1.3 Operation...5
More informationOxygen Measurement Systems High Reliability and Wide Application Coverage
Introduction High Process Efficiency Under Any Condition Oxygen Measurement Systems High Reliability and Wide Application Coverage METTLER TOLEDO provides sensors to measure dissolved oxygen (DO) in demanding
More informationIntelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter
Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter Overview C % ppm 4~20mA Analog Output ppb Power Supply 100~240 VAC mg/l Dimensions 96 x 96 x 132mm RS-485 Digital Output (for DC-5310-RS only)
More informationP499 Heavy Duty Pressure Transducer
P499 Heavy Duty Pressure Transducer Product Bulletin Code No. LIT-??? E Issued 11 2006 The P499 Series is a new global Pressure Transducer with an excellent price performance ratio. The P499 exceeds the
More informationABB MEASUREMENT & ANALYTICS DATA SHEET. WaterMaster FEW530 Electromagnetic water meter
ABB MEASUREMENT & ANALYTICS DATA SHEET WaterMaster FEW530 Electromagnetic water meter 2 WATE RMASTE R F E W 530 ELECT ROMAGNE TIC WATE R ME TE R DS/FE W530/FE T3 -E N RE V. A Measurement made easy Cost
More information200A Series ELECTRONIC LEVEL TRANSMITTER
MARINE - WATER AND PROCESS INDUSTRIES LIQUID LEVEL AND CONTENTS APPLICATIONS HYDROSTATIC OPERATION 200A Series ELECTRONIC LEVEL TRANSMITTER INTRINSICALLY SUBMERSIBLE - SCREWED MARINE SAFE FLANGED - HYGIENIC
More informationElectro-Pneumatic Converter YT-940 SERIES
Electro-Pneumatic Converter YT-940 SERIES PRODUCT MANUAL VERSION 1.00 Contents 1. Introduction 3 1.1 General information for the users. 3 1.2 Manufacturer Warranty 3 1.3 Explosion Proof Warning. 4 2. Product
More informationD-OptoLogger Dissolved Oxygen Logger Operation Manual
D-OptoLogger Dissolved Oxygen Logger Operation Manual Software version 3.4 Contents 1. Introduction..... 1 Optical Sensor Technology.....1 Features...... 1 2. D-OptoLogger Specifications.2 Specifications...
More informationMass Flow Controller (MFC) for Gases
Mass Flow Controller (MFC) for Gases Bypass MFC with capillary technology for nominal flow rates from 5 ml N /min to 15 l N /min Applicable for aggressive gases Compact design and digital communication
More informationPyroCouple Series Operators Guide
PyroCouple Series Operators Guide english PyroCouple, non-contact infrared sensors measure temperatures from -20 C to 500 C and provide either a linear 4 to 20mA output, a voltage output or a thermocouple
More informationDual position solenoid valve Type ICSH 25-80
Data sheet Dual position solenoid valve Type ICSH 25-80 ICSH dual position solenoid valve belongs to the ICV family and consists of an ICV housing, an ICS insert together with an ICSH top cover with 2
More informationCertified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters
www.kem-kueppers.com info@kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters Description The Tricor Mass Flow Meters measure simultaneously mass
More informationSupratec AERATION TECHNOLOGY. von-drais-straße 7 D Simmern / Hunsrück. tel.: / fax: /
PERMOX OM120 Oval Membrane Tu b e D i ffuser w i th stainless steel b o d y Supratec for fine bubble or coarse bubble diffusion of liquids Supratec UND GESELLSCHAFT FÜR UMWELT- VERFAHRENSTECHNIK MBH AERATION
More informationATM.ECO - Analog Pressure Transmitter
Pressure Transmitter ATM.ECO - Analog Pressure Transmitter CUSTOMER BENEFITS Entry level series into precision pressure measurement High measurement accuracy is ensured by sophisticated digital temperature
More informationE8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)
Pressure Sensor (Stainless Steel Diaphragm) CSM DS_E_3_1 Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications Incorporates double diaphragms consisting of SUS316L stainless
More informationOptical Dissolved Oxygen Meter
Optical Dissolved Oxygen Meter HI764113 Rugged Optical Dissolved Oxygen Probe for Fresh and Saltwater Applications Digital probe Fast and stable readings No membranes Not affected by sunlight No electrolytes
More informationModel GD402 Gas Density Meter
User s Manual Model GD402 Gas Density Meter 11th Edition (YK) Introduction The manual is applied to the following product. Detector: GD40G (General Purpose), GD40R (TIIS) (Style S2), GD40T
More informationINSTRUCTION MANUAL. 840 Transmitter. Loop Powered Dissolved Oxygen Transmitter
INSTRUCTION MANUAL Loop Powered Dissolved Oxygen Transmitter Contents Contents...2 Introduction...3 Range and Display Settings...4 Installation...5 Electrical Installation...6 Calibration...7 EasyCal...8
More informationProgrammable Submersible Level Transmitters
Programmable Submersible Level Transmitters PTM/N/RS485 CUSTOMER BENEFITS High flexibility due to scalalbe pressure range Digital (RS485) and analogue (4-20mA) output signal in one sensor Available as
More informationATM - Analog Pressure Transmitter
Pressure Transmitter ATM - Analog Pressure Transmitter CUSTOMER BENEFITS Fast customization thanks to configurable product design Demountable electrical connector option to allow adjustment of zero and
More information2/2-Way Solenoid Control Valve
2/2-Way Solenoid Control Valve Excellent range (1:200) Very good response Compact valve design Orifice sizes 0.05... 2.0 mm Port connection 1/8 or sub-base Type 2871 can be combined with Type 8605 Digital
More information