Effective Date: May Rev. 6/18/2018- Void After: May Product: Plumbing Fixture Fittings File No. 3489

Size: px
Start display at page:

Download "Effective Date: May Rev. 6/18/2018- Void After: May Product: Plumbing Fixture Fittings File No. 3489"

Transcription

1 IAPMO Research and Testing, Inc. is a product certification body which tests and inspects samples taken from the supplier's stock or from the market or a combination of both to verify compliance to the requirements of applicable codes and standards. This activity is coupled with periodic surveillance of the supplier's factory and warehouses as well as the assessment of the supplier's Quality Assurance System. This listing is subject to the conditions set forth in the characteristics below and is not to be construed as any recommendation, assurance or guarantee by IAPMO Research and Testing, Inc. of the product acceptance by Authorities Having Jurisdiction. The most updated information on this Certificate of Listing is available online at pld.iapmo.org Effective Date: May Rev. 6/18/2018- Void After: May Regency Parkway Suite 100 Cary, NC Identification: Each fitting shall bear permanent legible markings to identify the manufacturer. This marking shall be the trade name, trademark, or other mark known to identify the manufacturer. The product shall also bear all other markings required by the standard. The marking shall be located where it can be readily seen after installation is complete. The product shall also bear the cupc certification mark. Models in compliance with ICC/ANSI A117.1 shall be marked with "Also listed to ICC/ANSI A117.1" above the cupc certification mark. Characteristics: Plumbing fittings are to be installed in accordance with the manufacturer's instructions and the requirements of the latest edition of the Uniform Plumbing Code. Products listed on this certificate have been tested by an IAPMO R&T recognized laboratory. This recognition has been granted based upon the laboratory's compliance to the applicable requirements of ISO/IEC This listing period is based upon the last date of the month indicated on the Effective Date and Void After Date shown above. Any change in material, manufacturing process, marking or design without having first obtained the approval of the Product Certification Committee, or any evidence of non-compliance with applicable codes and standards or of inferior workmanship, may be deemed sufficient cause for revocation of this listing. Production of or reference to this form for advertising purposes may be made only by specific written permission of IAPMO Research and Testing, Inc. Any alteration of this certificate could be grounds for revocation of the listing. This document shall be reproduced in its entirety.

2 Products are in compliance with the following code(s): Uniform Plumbing Code (UPC ) National Plumbing Code of Canada International Plumbing Code (IPC ) Products are in compliance with the following standard(s): ASME A /CSA B

3 MODELS: Models designated by "*" also comply with ICC/ANSI A117.1 TPK7300-SS Standard valve w/trim and service stops TPK7300-SSC Standard valve w/trim w/copper sweat fittings and service stops TPK7320-SS Standard valve w/trim and screw on diverter and service stops TPK7320-SSC Standard valve w/trim, screw on diverter, copper sweat fittings & service stops Z7300-SS Standard valve w/trim Z7300-SSC Standard valve w/trim w/copper sweat fittings Z7320-SS Standard valve w/trim and screw on diverter Z7320-SSC Standard valve w/trim, screw on diverter and copper sweat fittings *Z744X-YYY Sierra lavatory faucet w/flexible supply hose *Z744X-CST-YYY Sierra lavatory faucet w/copper supply tubes Suffixes: *X = Waste Options (0=None, 1=LR, 2=MP and 3=GS) *1st Y = Handle Type (LP) *2nd Y = Aerator Type (FC, LA and VP) *3rd Y = Finish Options (STN) *FC = 0.5 GPM Aerator *GS = Grid Strainer *LA = Laminar Flow Aerator, 2.2 GPM *LP = Loop Handle *LR = Lift Rod *MP = Metal Pop-up *STN = Satin Nickel Finish *VP = Vandal-Resistant Aerator, 2.0 GPM *Z82200-## Single Control Lavatory Faucet Z-811XY Lavatory Faucet Z-827XY Lavatory Faucet Z-812XY Lavatory Faucet Z-871XY Kitchen Faucet Z-841XY Service Sink Body Z-842XY Service Sink Faucet Z-843XY-Z Service Sink Faucet Z-1996-SF Service Sink Body Z-866A0 Metering Z-867XY Metering Z Metering Z Metering Z Metering Page 3 of 17

4 Z M Metering Z Metering Z P Metering Z-825XY Laboratory Z-826XY Laboratory Z-821XY Health care/medical gooseneck spout Z-851XY Health care/medical faucet Z-851XY-WM Health care/medical faucet Z Health care/medical faucet Z LM Health care/medical faucet Z WM Health care/medical faucet Z Health care/medical faucet "X" in the model denotes Spout Type (A,B,C,F,G,H,I,J,K,L,M,N,Q,R,S,T,U) "Y" in the model denotes Handle Type (1,2,3,4,6) "Z" in the model denotes various options (140, 11F, 11M, 14F 14M, 16F, 16M, 17F, 17M, 18F, 18M, 1F, 1M, 2F, 2M, 3F, 3M, 4F, 4M, 7F, 7M, G, GH, WHK) ## Indicates the unit furnished with the following: 1M 2.2 GPM max aerator 2M 2.0 GPM aerator 3M 0.5 GPM aerator 4M 2.2 GPM max. laminar flow aerator 11M Less aerator 14M 2.2 GPM max. laminar flow aerator CP4 4" chrome plated zinc cover plate CP8 8" chrome plated zinc cover plate 18FH 18" S.S. braided flexible connectors * Z824XY-Z Single-Handle kitchen faucet with swing spout *Z " Centerset Metering Mixing Faucet *Z M 0.5 GPM Vandal-Resistant Pressure Compensating Male Spray Outlet *Z M 1.0 GPM Vandal-Resistant Pressure Compensating Male Spray Outlet X can be replaced with 0, A, B, C, S, Y indicating the spout style Y can be replaced with 0 indicating the handle style Z can be replaced with 0, 1F, 2F, 3F, 4F, 7F, 16F, 17F, 18F, 18FH with the following options: gpm standard aerator 1F-0.5 gpm spray type flow restrictor 2F-2.2 gpm aerated type junior flow restrictor 3F-0.5 gpm spray type junior flow restrictor 4F-2.2 gpm laminar type flow restrictor Page 4 of 17

5 7F-1.0 gpm spray type junior flow restrictor 16F-1.0 gpm spray type junior flow restrictor 17F-1.5 gpm aerated type junior flow restrictor 18F-1.5 gpm laminar type junior flow restrictor 18FH-18" gpm flexible inlet hose Z81200-XL 4 Centerset Lavatory Faucet Suffix -FC 2.0 GPM [7.6 L] Laminar Flow Control in Base of Spout -G 1-1/4 [32mm] Grid Strainer Drain -2F 2.2 GPM [8.3 L] Vandal-Resistant Pressure Compensating Female Aerator -3F 0.5 GPM [1.9 L] Vandal-Resistant Pressure Compensating Female Aerator -4F 2.2 GPM [8.3 L] Vandal-Resistant Pressure Compensating Female Laminar Flow -7F 1.0 GPM [3.8 L] Pressure Compensating Female Spray Outlet -16F 1.0 GPM [3.8 L] Vandal Resistant Pressure Compensating Female Spray Outlet -17F 1.5 GPM [5.7 L] Vandal Resistant Pressure Compensating Female Aerator -18F 1.5 GPM [5.7 L] Vandal Resistant Pressure Compensating Female Laminar Flow -21F 1.0 GPM [3.8L] Female Laminar Flow Outlet -22F 1.0 GPM [3.8L] Vandal-Resistant Female Laminar Flow Outlet -23F 1.5 GPM [5.7L] Pressure Compensating Female Aerator Z82100-XL Health Care/Medical Gooseneck Spout -WM Wall Mount Z82500-XL Laboratory Faucet Single Suffix -AR Anti-Rotation Pins -FC 2.0 GPM [7.6 L] Laminar Flow Control in Base of Spout -G 1-1/4" [32mm] Grid Strainer Drain -2F 2.2 GPM [8.3 L] Vandal-Resistant Pressure Compensating Female Aerator -3F 0.5 GPM [1.9 L] Vandal-Resistant Pressure Compensating Female Spray Outlet -4F 2.2 GPM [8.3 L] Vandal-Resistant Pressure Compensating Female Laminar Flow Outlet -7F 1.0 GPM [3.8 L] Pressure Compensating Female Spray Outlet -16F 1.0 GPM [3.8 L] Vandal Resistant Pressure Compensating Female Spray Outlet -17F 1.5 GPM [5.7 L] Vandal Resistant Pressure Compensating Female Aerator -18F 1.5 GPM [5.7 L] Vandal Resistant Pressure Compensating Female Laminar Flow Page 5 of 17

6 -21F 1.0 GPM [3.8L] Female Laminar Flow Outlet -22F 1.0 GPM [3.8L] Vandal-Resistant Female Laminar Flow Outlet -23F 1.5 GPM [5.7L] Pressure Compensating Female Aerator Z82600-XL Laboratory Faucet Suffix -AR Anti-Rotation Pins -CST Copper Supply Tubes -FC 2.0 GPM [7.6 L] Laminar Flow Control in Base of Spout -G 1-1/4" [32mm] Grid Strainer Drain -MY Mixing Yoke Assembly Instead of Copper Supplies -140 Restricted 140j Swing Spout -2F 2.2 GPM [8.3 L] Vandal-Resistant Pressure Compensating Female Aerator -3F 0.5 GPM [1.9 L] Vandal-Resistant Pressure Compensating Female Spray Outlet -4F 2.2 GPM [8.3 L] Vandal-Resistant Pressure Compensating Female Laminar Flow Outlet -7F 1.0 GPM [3.8L] Pressure Compensating Female Spray Outlet -16F 1.0 GPM [3.8L] Vandal-Resistant Pressure Compensating Female Spray Outlet -17F 1.5 GPM [5.7L] Vandal-Resistant Pressure Compensating Female Aerator -18F 1.5 GPM [5.7L] Vandal-Resistant Pressure Compensating Female Laminar Flow Outlet -22F 1.0 GPM [3.8L] Pressure Compensating Vandal-Resistant Female Laminar Flow Outlet -23F 1.5 GPM [5.7L] Pressure Compensating Female Aerator Z83100-XL Widespread Kitchen Faucet Suffix -CWO Cold Water Only -FC 2.0 GPM [7.6 L] Laminar Flow Control in Base of Spout -G 1-1/4" [32mm] Grid Strainer Drain -GH 1-1/4" [32mm] Offset Handicap Grid Drain -HS Hose and Spray -ICT Inter-connecting Copper Supply Tubes for 8 In-line Centers -P 1-1/4" [32mm] Pop-up Drain -PT 1-1/4 [32mm] Cast Brass P-Trap with a 7-1/2 [191mm] Long 17-Gauge Wall Bend -TW Third Waterway -2F 2.2 GPM [8.3 L] Vandal-Resistant Pressure Compensating Female Aerator -3F 0.5 GPM [1.9 L] Vandal-Resistant Pressure Compensating Female Spray Outlet -4F 2.2 GPM [8.3 L] Vandal-Resistant Pressure Compensating Female Laminar Flow Outlet -7F 1.0 GPM [3.8L] Pressure Compensating Female Spray Outlet -16F 1.0 GPM [3.8L] Vandal-Resistant Pressure Compensating Female Spray Outlet Page 6 of 17

7 -17F 1.5 GPM [5.7L] Vandal-Resistant Pressure Compensating Female Aerator -18F 1.5 GPM [5.7L] Vandal-Resistant Pressure Compensating Female Laminar Flow Outlet -20F 1.0 GPM [3.8L] Vandal-Resistant Pressure Compensating Anti-Microbial Female Laminar Flow Outlet -21F 1.0 GPM [3.8L] Female Laminar Flow Outlet -22F 1.0 GPM [3.8L] Vandal-Resistant Female Laminar Flow Outlet Z84100-XL Wall Mounted Service Sink Faucet Suffix -FC 2.0 GPM [7.6 L] Laminar Flow Control in Base of Spout -SSI 3/8" [10mm] Short Swivel Inlets -2F 2.2 GPM [8.3 L] Vandal-Resistant Pressure Compensating Female Aerator -3F 0.5 GPM [1.9 L] Vandal-Resistant Pressure Compensating Female Spray Outlet -4F 2.2 GPM [8.3 L] Vandal-Resistant Pressure Compensating Female Laminar Flow Outlet -7F 1.0 GPM [3.8L] Pressure Compensating Female Spray Outlet -15F Female Full Flow Outlet -16F 1.0 GPM [3.8L] Vandal-Resistant Pressure Compensating Female Spray Outlet -17F 1.5 GPM [5.7L] Vandal-Resistant Pressure Compensating Female Aerator -18F 1.5 GPM [5.7L] Vandal-Resistant Pressure Compensating Female Laminar Flow Outlet -22F 1.0 GPM [3.8L] Pressure Compensating Vandal-Resistant Female Laminar Flow Outlet -23F 1.5 GPM [5.7L] Pressure Compensating Female Aerator o Restricted Swing Spout Z84200-XL Wall Mounted Service Sink Faucet Suffix -FC 2.0 GPM [7.6 L] Laminar Flow Control in Base of Spout -LSI 2-1/2" [64mm] Long Swivel Inlets with Integral Stops -2F 2.2 GPM [8.3 L] Vandal-Resistant Pressure Compensating Female Aerator -3F 0.5 GPM [1.9 L] Vandal-Resistant Pressure Compensating Female Spray Outlet -4F 2.2 GPM [8.3 L] Vandal-Resistant Pressure Compensating Female Laminar Flow Outlet -7F 1.0 GPM [3.8 L] Pressure Compensating Female Spray Outlet -16F 1.0 GPM [3.8 L] Vandal Resistant Pressure Compensating Female Spray Outlet -17F 1.5 GPM [5.7 L] Vandal Resistant Pressure Compensating Female Aerator -18F 1.5 GPM [5.7 L] Vandal Resistant Pressure Compensating Female Laminar Flow -22F 1.0 GPM [3.8L] Vandal-Resistant Pressure Compensating Female Laminar Flow Outlet -23F 1.5 GPM [5.7L] Pressure Compensating Female Aerator Page 7 of 17

8 Z84300-XL Wall Mounted Service Sink Faucet Suffix -CS Check Stops -LSI 2-1/2" [64mm] Long Swivel Inlets -2F 2.2 GPM [8.3 L] Vandal-Resistant Pressure Compensating Female Aerator -3F 0.5 GPM [1.9 L] Vandal-Resistant Pressure Compensating Female Spray Outlet -4F 2.2 GPM [8.3 L] Vandal-Resistant Pressure Compensating Female Laminar Flow Outlet -7F 1.0 GPM [3.8 L] Pressure Compensating Female Spray Outlet -16F 1.0 GPM [3.8L] Vandal-Resistant Pressure Compensating Female Spray Outlet -17F 1.5 GPM [5.7L] Vandal-Resistant Pressure Compensating Female Aerator -18F 1.5 GPM [5.7L] Vandal-Resistant Pressure Compensating Female Laminar Flow Outlet -22F 1.0 GPM [3.8L] Vandal-Resistant Pressure Compensating Z87100-XL Kitchen Faucet Suffix -FC 2.0 GPM [7.6 L] Laminar Flow Control in Base of Spout -HS Hose and Spray -2F 2.2 GPM [8.3 L] Vandal-Resistant Pressure Compensating Female Aerator -3F 0.5 GPM [1.9 L] Vandal-Resistant Pressure Compensating Female Spray Outlet -4F 2.2 GPM [8.3 L] Vandal-Resistant Pressure Compensating Female Laminar Flow -7F 1.0 GPM [3.8 L] Pressure Compensating Female Spray Outlet -16F 1.0 GPM [3.8 L] Vandal Resistant Pressure Compensating Female Spray Outlet -17F 1.5 GPM [5.7 L] Vandal Resistant Pressure Compensating Female Aerator -18F 1.5 GPM [5.7 L] Vandal Resistant Pressure Compensating Female Laminar Flow -22F 1.0 GPM [3.8L] Vandal-Resistant Pressure Compensating Female Laminar Flow Outlet -23F 1.5 GPM [5.7L] Pressure Compensating Female Aerator -24F 0.35 GPM [1.3 L] Pressure Compensating Female Spray Outlet -25F 0.35 GPM [1.3 L] Vandal-Resistant Pressure Compensating Female Spray Outlet Z81000-XL 4 Centerset Single Control Lavatory Faucet Suffix -G 1-1/4 [32mm] Grid Strainer Drain -P 1-1/4 [32mm] Pop-up Drain -PT 1-1/4 [32mm] Cast Brass P-Trap with a 7-1/2 [191mm] Long 17-Gauge Wall Bend -1M 2.2 GPM [8.3 L] Variable-Pressure Compensating Male Aerator Page 8 of 17

9 -2M 2.2 GPM [8.3 L] Vandal-Resistant Pressure Compensating Male Aerator -3M 0.5 GPM [1.9 L] Vandal-Resistant Pressure Compensating Male Aerator -4M 2.2 GPM [8.3 L] Vandal-Resistant Pressure Compensating Male Laminar Flow -7M 1.0 GPM [3.8 L] Pressure Compensating Male Spray Outlet -16M 1.0 GPM [3.8 L] Vandal-Resistant Pressure Compensating Male Spray Outlet -17M 1.5 GPM [5.7 L] Vandal-Resistant Pressure Compensating Male Aerator -18M 1.5 GPM [5.7 L] Vandal-Resistant Pressure Compensating Laminar Flow -19M 1.5 GPM [5.7 L] Anti-Microbial Pressure Compensating Male Laminar Flow Outlet -21M 1.0 GPM [3.8L] Male Laminar Flow Outlet -22M 1.0 GPM [3.8L] Vandal-Resistant Male Laminar Flow Outlet -23M 1.5 GPM [5.7L] Pressure Compensating Male Aerator -24M 0.35 GPM [1.3 L] Pressure Compensating Male Spray Outlet -25M 0.35 GPM [1.3 L] Vandal-Resistant Pressure Compensating Male Spray Outlet Z82200-XL Single Control Lavatory Faucet Suffix -CP8 Chrome Plated 8 [203mm] Cover Plate -CST Copper Supply Tubes -G 1-1/4 [32mm] Grid Strainer Drain -P 1-1/4 [32mm] Pop-up Drain -2M 2.2 GPM [8.3 L] Vandal-Resistant Pressure Compensating Male Aerator -3M.5 GPM [1.9 L] Vandal-Resistant Pressure Compensating Male Spray Outlet -4M 2.2 GPM [8.3 L] Vandal-Resistant Pressure Compensating Male Laminar Flow Outlet -7M 1.0 GPM [3.8 L] Pressure Compensating Male Spray Outlet -16M 1.0 GPM [3.8 L] Vandal Resistant Pressure Compensating Male Spray Outlet -17M 1.5 GPM [5.7 L] Vandal Resistant Pressure Compensating Male Aerator -18FH 18 [457mm] S.S. Braided Flex Hoses -18M 1.5 GPM [5.7 L] Vandal Resistant Pressure Compensating Male Laminar Flow -19M 1.5 GPM [5.7 L] Anti-Microbial Pressure Compensating Male Laminar Flow Outlet -21M 1.0 GPM [3.8L] Pressure Compensating Male Laminar Flow Outlet -22M 1.0 GPM [3.8L] Pressure Compensating Vandal-Resistant Male Laminar Flow Outlet -23M 1.5 GPM [5.7L] Pressure Compensating Male Aerator Z82300-XL Single Control Kitchen Faucet Suffix -CP4 Chrome Plated 4 [102mm] Cover Plate -CP8 Chrome Plated 8 [203mm] Cover Plate -CST Copper Supply Tubes -G 1-1/4 [32mm] Grid Strainer Drain -HS Hose and Spray -2M 2.2 GPM [8.3 L] Vandal-Resistant Pressure Compensating Male Aerator -3M 0.5 GPM [1.9 L] Vandal-Resistant Pressure Compensating Male Spray Outlet -4M 2.2 GPM [8.3 L] Vandal-Resistant Pressure Compensating Male Laminar Flow Outlet -7M 1.0 GPM [3.8 L] Pressure Compensating Male Spray Outlet Page 9 of 17

10 -16M 1.0 GPM [3.8 L] Vandal-Resistant Pressure Compensating Male Spray Outlet -17M 1.5 GPM [5.7 L] Vandal-Resistant Pressure Compensating Male Aerator -18FH 18 [457mm] S.S. Braided Flex Hoses -18M 1.5 GPM [5.7 L] Vandal-Resistant Pressure Compensating Male Laminar Flow -19M 1.5 GPM [5.7 L] Anti-Microbial Pressure Compensating Male Laminar Flow Outlet -21M 1.0 GPM [3.8L] Male Laminar Flow Outlet -22M 1.0 GPM [3.8L] Vandal-Resistant Male Laminar Flow Outlet -23M 1.5 GPM [5.7L] Pressure Compensating Male Aerator Z82400-XL Single Control Kitchen Faucet Suffix -CST Copper Supply Tubes -FC 2.0 GPM [7.6L] Laminar Flow Control in Base of Spout -HS Hose and Spray -2F 2.2 GPM [8.3 L] Vandal-Resistant Pressure Compensating Female Aerator -3F 0.5 GPM [1.9 L] Vandal-Resistant Pressure Compensating Female Spray Outlet -4F 2.2 GPM [8.3 L] Vandal-Resistant Pressure Compensating Female Laminar Flow Outlet -7F 1.0 GPM [3.8L] Pressure Compensating Female Spray Outlet -15F Female Full Flow Outlet -16F 1.0 GPM [3.8L] Vandal-Resistant Pressure Compensating Female Spray Outlet -17F 1.5 GPM [5.7L] Vandal-Resistant Pressure Compensating Female Aerator -18F 1.5 GPM [5.7L] Vandal-Resistant Pressure Compensating Female Laminar Flow Outlet -18FH 18 [457mm] S.S. Braided Flex Hose -22F 1.0 GPM [3.8L] Pressure Compensating Vandal-Resistant Female Laminar Flow Outlet -23F 1.5 GPM [5.7L] Pressure Compensating Female Aerator o Restricted Swing Gooseneck Spout Z81100-XL 4 Centerset Dual Handle Control Lavatory Faucet -G 1-1/4" [32mm] Grid Strainer Drain -2M 2.2 GPM [8.3 L] Vandal-Resistant Pressure Compensating Male Aerator -3M 0.5 GPM [1.9 L] Vandal-Resistant Pressure Compensating Male Aerator -4M 2.2 GPM [8.3 L] Vandal-Resistant Pressure Compensating Male Laminar Flow -7M 1.0 GPM [3.8 L] Pressure Compensating Male Spray Outlet -16M 1.0 GPM [3.8 L] Vandal-Resistant Pressure Compensating Male Spray Outlet -17M 1.5 GPM [5.7 L] Vandal-Resistant Pressure Compensating Male Aerator -18M 1.5 GPM [5.7 L] Vandal-Resistant Pressure Compensating Male Laminar Flow -22F 1.0 GPM [3.8L] Vandal-Resistant Pressure Compensating Female Laminar Flow Outlet -23F 1.5 GPM [5.7L] Pressure Compensating Female Aerator Page 10 of 17

11 -24M 0.35 GPM [1.3 L] Pressure Compensating Male Spray Outlet -25M 0.35 GPM [1.3 L] Vandal-Resistant Pressure Compensating Male Spray Outlet Z82700-XL Single Lavatory Faucet - CP4 Chrome-Plated 4 [102mm] Cover Plate -G 1-1/4" [32mm] Grid Strainer Drain -2M 2.2 GPM [8.3 L] Vandal-Resistant Pressure Compensating Male Aerator -3M.5 GPM [1.9 L] Vandal-Resistant Pressure Compensating Male Spray Outlet -4M 2.2 GPM [8.3 L] Vandal-Resistant Pressure Compensating Male Laminar Flow Outlet -7M 1.0 GPM [3.8 L] Pressure Compensating Male Spray Outlet -16M 1.0 GPM [3.8 L] Vandal Resistant Pressure Compensating Male Spray Outlet -17M 1.5 GPM [5.7 L] Vandal Resistant Pressure Compensating Male Aerator -18M 1.5 GPM [5.7 L] Vandal Resistant Pressure Compensating Male Laminar Flow -19M 1.5 GPM [5.7 L] Anti-Microbial Pressure Compensating Male Laminar Flow Outlet -21M 1.0 GPM [3.8L] Pressure Compensating Male Laminar Flow Outlet -22M 1.0 GPM [3.8L] Pressure Compensating Vandal-Resistant Male Laminar Flow Outlet -23M 1.5 GPM [5.7L] Pressure Compensating Male Aerator Z82600-XL Laboratory Faucet Suffix -AR Anti-Rotation Pins -CST Copper Supply Tubes -FC 2.0 GPM [7.6 L] Laminar Flow Control in Base of Spout -G 1-1/4" [32mm] Grid Strainer Drain -MY Mixing Yoke Assembly Instead of Copper Supplies -140 Restricted 140j Swing Spout -2F 2.2 GPM [8.3 L] Vandal-Resistant Pressure Compensating Female Aerator -3F 0.5 GPM [1.9 L] Vandal-Resistant Pressure Compensating Female Spray Outlet -4F 2.2 GPM [8.3 L] Vandal-Resistant Pressure Compensating Female Laminar Flow Outlet -7F 1.0 GPM [3.8L] Pressure Compensating Female Spray Outlet -16F 1.0 GPM [3.8L] Vandal-Resistant Pressure Compensating Female Spray Outlet -17F 1.5 GPM [5.7L] Vandal-Resistant Pressure Compensating Female Aerator -18F 1.5 GPM [5.7L] Vandal-Resistant Pressure Compensating Female Laminar Flow Outlet -22F 1.0 GPM [3.8L] Pressure Compensating Vandal-Resistant Female Laminar Flow Outlet Z86100-XL Single Basin Metering Faucet Page 11 of 17

12 Suffix -CS Check Stop -CP4 Chrome-Plated 4 [102mm] Cover Plate -G 1-1/4" [32mm] Grid Strainer Drain -GH 1-1/4" [32mm] Offset Handicap Drain -IN Institutional Handle- Tamper-Proof and Vandal-Resistant -RKR ADA Compliant Rocker Handle -3M 0.5 GPM [1.9 L] Vandal-Resistant Pressure Compensating Male Spray Outlet -7M 1.0 GPM [3.8 L] Pressure Compensating Male Spray Outlet -16M 1.0 GPM [3.8 L] Vandal-Resistant Pressure Compensating Male Spray Outlet -21M 1.0 GPM [3.8L] Pressure Compensating Male Laminar Flow Outlet -22M 1.0 GPM [3.8L] Pressure Compensating Vandal-Resistant Male Laminar Flow Outlet -24M 0.35 GPM [1.3 L] Pressure Compensating Male Spray Outlet -25M 0.35 GPM [1.3 L] Vandal-Resistant Pressure Compensating Male Spray Outlet Z86300-XL Single Basin Metering Faucet -CS Check Stops -G 1-1/4 [32mm] Grid Strainer Drain -GH 1-1/4 [32mm] Offset Handicap Grid Drain -IN Institutional Handle - Tamper-Proof and Vandal-Resistant -MY Mixing Yoke -MYCS Mixing Yoke with Check Stops -3M 0.5 GPM [1.9 L] Vandal-Resistant Pressure Compensating Male Spray Outlet -16M 1.0 GPM [3.8 L] Vandal-Resistant Pressure Compensating Male Spray Outlet -21M 1.0 GPM [3.8L] Male Laminar Flow Outlet -22M 1.0 GPM [3.8L] Vandal-Resistant Male Laminar Flow Outlet -24M 0.35 GPM [1.3 L] Pressure Compensating Male Spray Outlet -25M 0.35 GPM [1.3 L] Vandal-Resistant Pressure Compensating Male Spray Outlet Z86500-XL 4 Centerset Metering Faucet Suffix -G 1-1/4" [32mm] Grid Strainer Drain -GH 1-1/4" [32mm] Offset Handicap Drain -IN Institutional Handle- Tamper-Proof and Vandal-Resistant -RKR ADA Compliant Rocker Handle -3M.5 GPM [1.9 L] Vandal-Resistant Pressure Compensating Male Spray Outlet -16M 1.0 GPM [3.8 L] Vandal Resistant Pressure Compensating Male Spray Outlet -21M 1.0 GPM [3.8L] Pressure Compensating Male Laminar Flow Outlet -22M 1.0 GPM [3.8L] Pressure Compensating Vandal-Resistant Male Laminar Flow Outlet -24M 0.35 GPM [1.3 L] Pressure Compensating Male Spray Outlet -25M 0.35 GPM [1.3 L] Vandal-Resistant Pressure Compensating Male Spray Outlet Page 12 of 17

13 Z86600-XL 4 Centerset Metering Faucet Suffix -G 1-1/4 [32mm] Grid Strainer Drain -GH 1-1/4 [32mm] Offset Handicap Grid Drain -IN Institutional Handle - Tamper-Proof and Vandal-Resistant -P 1-1/4 [32mm] Pop-up Drain -RKR ADA Compliant Rocker Handle Restricted Swing Spout -3F.5 GPM [1.9 L] Vandal-Resistant Pressure Compensating Female Spray Outlet -16F 1.0 GPM [3.8 L] Vandal Resistant Pressure Compensating Female Spray Outlet -22F 1.0 GPM [3.8L] Pressure Compensating Vandal-Resistant Female Laminar Flow Outlet -24F 0.35 GPM [1.3 L] Pressure Compensating Female Spray Outlet -25F 0.35 GPM [1.3 L] Vandal-Resistant Pressure Compensating Female Spray Outlet Z86700-XL Widespread metering faucet Suffix -CWO Cold Water Only -G 1-1/4" [32mm] Grid Strainer Drain -GH 1-1/4" [32mm] Offset Handicap Drain -ICT Inter-connecting Copper Supply Tubes for 8 In-line Centers -IN Institutional Handle - Tamper-Proof and Vandal-Resistant -P 1-1/4" [32mm] Pop-up Drain -RKR ADA Compliant Rocker Handle o Restricted Swing Spout -3F.5 GPM [1.9 L] Vandal-Resistant Pressure Compensating Female Spray Outlet -16F 1.0 GPM [3.8 L] Vandal Resistant Pressure Compensating Female Spray Outlet -22F 1.0 GPM [3.8L] Pressure Compensating Vandal-Resistant Female Laminar Flow Outlet -24F 0.35 GPM [1.3 L] Pressure Compensating Female Spray Outlet -25F 0.35 GPM [1.3 L] Vandal-Resistant Pressure Compensating Female Spray Outlet Z80300-XL Wall Mounted Single Metering Faucet -IN -RKR Institutional Handle Rocker Handle AquaSense Electronic Sensor Faucets Page 13 of 17

14 Z6913-XL-z Z6915-XL-z Z6920-XL-x-z Z6920XT-XL-x-z Z6923-XL-x-z Z6922-XL-x-z Z6922XT-XL-x-z Z6930-XL-z Z6950-XL-IM-S-z Z6950-XL-S-z Z6951-XL-z Z6952-XL-z Z6953-XL-z Z6954-XL-z Z6955-XL-S-z Z6956-XL-z Z6957-XL-z Deck Mount Sensor-operated Faucet (Three Hole) Deck Mount Sensor-operated Faucet Deck Mount Goose Neck Sensor-operated Faucet Deck Mount Goose Neck Sensor-operated Faucet (Extended Range Sensor) Deck Mount Goose Neck Sensor-operated Faucet Wall Mount Goose Neck Sensor-operated Faucet Wall Mount Goose Neck Sensor-operated Faucet (Extended Range Sensor) Deck Mount Sensor operated Faucet Deck Mount Sensor-operated Faucet with Integral Mixing Valve Deck Mount Sensor-operated Faucet Sensor-operated Lav Faucet Wall Mount Sensor- operated Faucet Deck Mount Sensor-operated Faucet Deck Mount Sensor-operated Faucet Deck Mount Sensor-operated Faucet (Three Hole) Deck Mount Sensor-operated Faucet NACHI Wall-Mounted Sensor Lavatory Faucet x = spout options (0, GA, GA-FC, GB, GB-FC, GC, GC-FC, GC-10, GC-10-FC) -GA -GA-FC -GB -GB-FC -GC -GC-FC -GC-10 -GC-10-FC G /2" centerline gooseneck spout G /2" centerline gooseneck spout with Flow Control G /8" centerline gooseneck spout G /8" centerline gooseneck spout with Flow Control G " centerline gooseneck spout G " centerline gooseneck spout with Flow Control G " centerline gooseneck spout G " centerline gooseneck spout with Flow Control z= miscellaneous options (ACA, ADM, CP4, CP8, CWB, E, F, GEN, HW6, J, K, L, M, MJ, MV, N, SH, SSH, TMV-1, XT) -ACA -ADM -BN -CP4 -CP8 -CWB -GEN -HW6 -MJ -MT -MV -TMV-1 -SH P6900-ACA, P6957-ACA, 6 VDC A/C Plug-In Adapter P6900-ADM-XL, Above-Deck Mixer Brushed Nickel P6900-CP4, 4" Cover plate P6900-CP8, 8" Cover plate P6900-CWB, connecting wire for power converter P6900-GEN-XL, hydro generator power P6000-HW6, hardwired power converter P6000-MJ, mini junction box P6900-MT-XL, mixing tee P6900-MV-XL, manual mixing valve P6900-TMV-1, thermostatic mixing valve for single faucet P6900-SH, three piece supply hose assembly Page 14 of 17

15 -SSH P6900-SSH, single supply hose -FC GPM Flow Control ( ) -FC GPM Flow Control ( ) -FC GPM Flow Control ( ) -FC GPM Flow Control ( ) -FC GPM Flow Control ( ) -20E-GN-CG 1.5 GPM spray outlet, with Careguard, female ( ) -20E-CG 1.5 GPM spray outlet, with Careguard, male ( ) -PN Polished Nickel -PB Polished Brass -XT Extended Range Sensor -z miscellaneous options (ACA, ADM, CP4, CP8, CWB, E, F, GEN, HW6, J, K, L, M, MJ, MV, N, SH, SSH, TMV-1, XT) Aerators P E -E, 1.5 GPM spray outlet, male ( ) P ES -ES, 1.5 GPM slim spray outlet, male ( ) P E-GN -E, 1.5 GPM spray outlet, female (G66695) P F -F, 0.5 GPM vandal resistant spray outlet, male ( ) P FS -FS, 0.5 GPM slim spray outlet, male ( ) P F-GN -F, 0.5 GPM vandal resistant spray outlet, female ( ) P J -J, 1.5 GPM vandal resistant laminar flow, male ( ) P JS -JS, 1.5 GPM slim laminar flow, male ( ) P J-GN -J, 1.5 GPM vandal resistant laminar flow, female ( ) P K -K, 1.0 GPM laminar flow, male ( ) P K-GN -K, 1.0 GPM laminar flow, female ( ) P L -L, 1.0 GPM spray outlet, male ( ) P LS -LS, 1.5 GPM slim laminar flow, male ( ) P L-GN -L, 1.0 GPM spray outlet, female ( ) P M -M, 0.35 GPM spray outlet, male ( ) P MS -MS, 0.35 GPM slim spray outlet, male ( ) P M-GN -M, 0.35 GPM spray outlet, female ( ) P N -N, 0.5 GPM laminar flow, male ( ) P E -E, 1.5 GPM vandal resistant hidden spray outlet, male ( ) P F -F, 0.5 GPM vandal resistant hidden spray outlet, male ( ) P J -J, 1.5 GPM vandal resistant hidden laminar flow, male ( ) P K -K, 1.0 GPM vandal resistant hidden laminar flow, male ( ) P L -L, 1.0 GPM vandal resistant hidden spray outlet, male ( ) P M -M, 0.35 GPM vandal resistant hidden spray outlet, male ( ) P N -N, 0.5 GPM vandal resistant hidden laminar flow, male ( ) E, 1.5 gpm spray outlet, female F, 0.5 gpm vandal resistant spray outlet, female Page 15 of 17

16 J, 1.5 gpm vandal resistant laminar flow, female K, 1.0 gpm laminar flow, female L, 1.0 gpm spray outlet, female M, 0.35 gpm spray outlet, female gpm Flow Control gpm Flow Control gpm Flow Control gpm Flow Control gpm Flow Control 1. "X" in the model number denotes spout type (A, B, C, DE F, G H, H, I, J, K, L, M, N, Q, R, S, T, U). 2. "Y" In the model number denotes Handle Type (1, 2, 3, 4, 6) 3. Additional suffix may be added to denote accessories Supply Stops Only Z81006-XL Qtr Turn Stop (1/2" COMP x 1/2" NPT) (Lead Free) Z81017-XL Qtr Turn Stop (3/8" COMP x 1/2" NPT) (Lead Free) Z81005-XL Qtr Turn Stop (1/2" COMP x 3/8" NPT) (Lead Free) Z81016-XL Qtr Turn Stop (3/8" COMP x 3/8" NPT) (Lead Free) Stop & Flex Hose Z81005-XL-LR PC Qtr Turn Stop (1/2" COMP X 3/8" NPT) w/ 12" SS Hose Z81005-XL-LR PC Qtr Turn Stop (1/2" COMP X 3/8" NPT) w/ 16" SS Hose Z81005-XL-LR PC Qtr Turn Stop (1/2" COMP X 3/8" NPT) w/ 20" SS Hose Z81005-XL-LR PC Qtr Turn Stop (1/2" COMP X 3/8" NPT) w/ 30" SS Hose *Z81005-XL-LR PC Qtr Turn Stop (1/2" COMP X 3/8" NPT) w/ 36" SS Hose Z81006-XL-LR PC Qtr Turn Stop (1/2" COMP X 1/2" NPT) w/ 12" SS Hose Z81006-XL-LR PC Qtr Turn Stop (1/2" COMP X 1/2" NPT) w/ 16" SS Hose Z81006-XL-LR PC Qtr Turn Stop (1/2" COMP X 1/2" NPT) w/ 20" SS Hose Z81006-XL-LR PC Qtr Turn Stop (1/2" COMP X 1/2" NPT) w/ 30" SS Hose *Z81006-XL-LR PC Qtr Turn Stop (1/2" COMP X 1/2" NPT) w/ 36" SS Hose Z81016-XL-LR PC Qtr Turn Stop (3/8" COMP X 3/8" NPT) w/ 12" SS Hose Z81016-XL-LR PC Qtr Turn Stop (3/8" COMP X 3/8" NPT) w/ 16" SS Hose Z81016-XL-LR PC Qtr Turn Stop (3/8" COMP X 3/8" NPT) w/ 20" SS Hose Z81016-XL-LR PC Qtr Turn Stop (3/8" COMP X 3/8" NPT) w/ 30" SS Hose *Z81016-XL-LR PC Qtr Turn Stop (3/8" COMP X 3/8" NPT) w/ 36" SS Hose Z81016-XL-LR PC Qtr Turn Stop (3/8" COMP X 3/8" NPT) w/ 12" SS Hose Z81016-XL-LR PC Qtr Turn Stop (3/8" COMP X 3/8" NPT) w/ 16" SS Hose Z81016-XL-LR PC Qtr Turn Stop (3/8" COMP X 3/8" NPT) w/ 20" SS Hose Z81016-XL-LR PC Qtr Turn Stop (3/8" COMP X 3/8" NPT) w/ 30" SS Hose *Z81016-XL-LR PC Qtr Turn Stop (3/8" COMP X 3/8" NPT) w/ 36" SS Hose Z81017-XL-LR PC Qtr Turn Stop (3/8" COMP X 1/2" NPT) w/ 12" SS Hose Z81017-XL-LR PC Qtr Turn Stop (3/8" COMP X 1/2" NPT) w/ 16" SS Hose Z81017-XL-LR PC Qtr Turn Stop (3/8" COMP X 1/2" NPT) w/ 20" SS Hose Page 16 of 17

17 Z81017-XL-LR PC Qtr Turn Stop (3/8" COMP X 1/2" NPT) w/ 30" SS Hose *Z81017-XL-LR PC Qtr Turn Stop (3/8" COMP X 1/2" NPT) w/ 36" SS Hose Z81017-XL-LR PC Qtr Turn Stop (3/8" COMP X 1/2" NPT) w/ 12" SS Hose Z81017-XL-LR PC Qtr Turn Stop (3/8" COMP X 1/2" NPT) w/ 16" SS Hose Z81017-XL-LR PC Qtr Turn Stop (3/8" COMP X 1/2" NPT) w/ 20" SS Hose Z81017-XL-LR PC Qtr Turn Stop (3/8" COMP X 1/2" NPT) w/ 30" SS Hose *Z81017-XL-LR PC Qtr Turn Stop (3/8" COMP X 1/2" NPT) w/ 36" SS Hose Stop & Lavatory Riser Tube Z81005-XL-LR PC Qtr Turn Stop (1/2" COMP X 3/8" NPT) w/ 12" Riser Tube Z81005-XL-LR PC Qtr Turn Stop (1/2" COMP X 3/8" NPT) w/ 20" Riser Tube Z81006-XL-LR PC Qtr Turn Stop (1/2" COMP X 1/2" NPT) w/ 12" Riser Tube Z81006-XL-LR PC Qtr Turn Stop (1/2" COMP X 1/2" NPT) w/ 20" Riser Tube Z81016-XL-LR PC Qtr Turn Stop (3/8" COMP X 3/8" NPT) w/ 12" Riser Tube Z81016-XL-LR PC Qtr Turn Stop (3/8" COMP X 3/8" NPT) w/ 15" Riser Tube Z81016-XL-LR PC Qtr Turn Stop (3/8" COMP X 3/8" NPT) w/ 20" Riser Tube Z81016-XL-LR PC Qtr Turn Stop (3/8" COMP X 3/8" NPT) w/ 30" Riser Tube *Z81016-XL-LR PC Qtr Turn Stop (3/8" COMP X 3/8" NPT) w/ 36" Riser Tube Z81017-XL-LR PC Qtr Turn Stop (3/8" COMP X 1/2" NPT) w/ 12" Riser Tube Z81017-XL-LR PC Qtr Turn Stop (3/8" COMP X 1/2" NPT) w/ 15" Riser Tube Z81017-XL-LR PC Qtr Turn Stop (3/8" COMP X 1/2" NPT) w/ 20" Riser Tube Z81017-XL-LR PC Qtr Turn Stop (3/8" COMP X 1/2" NPT) w/ 30" Riser Tube *Z81017-XL-LR PC Qtr Turn Stop (3/8" COMP X 1/2" NPT) w/ 36" Riser Tube Stop & Closet Riser Tube Z81005-XL-CR PC Qtr Turn Stop (1/2" COMP X 3/8" NPT) w/ 12" Riser Tube Z81005-XL-CR PC Qtr Turn Stop (1/2" COMP X 3/8" NPT) w/ 15" Riser Tube Z81006-XL-CR PC Qtr Turn Stop (1/2" COMP X 1/2" NPT) w/ 12" Riser Tube Z81006-XL-CR PC Qtr Turn Stop (1/2" COMP X 1/2" NPT) w/ 15" Riser Tube Z81016-XL-CR PC Qtr Turn Stop (3/8" COMP X 3/8" NPT) w/ 12" Riser Tube Z81016-XL-CR PC Qtr Turn Stop (3/8" COMP X 3/8" NPT) w/ 15" Riser Tube Z81016-XL-CR PC Qtr Turn Stop (3/8" COMP X 3/8" NPT) w/ 20" Riser Tube Z81017-XL-CR PC Qtr Turn Stop (3/8" COMP X 1/2" NPT) w/ 12" Riser Tube Z81017-XL-CR PC Qtr Turn Stop (3/8" COMP X 1/2" NPT) w/ 15" Riser Tube Z81017-XL-CR PC Qtr Turn Stop (3/8" COMP X 1/2" NPT) w/ 20" Riser Tube Note: Models with an * shall bear the UPC mark. Page 17 of 17

Effective Date: January 2018 Void After: January Product: Fill Valves (Anti-Siphon) File No. 3733

Effective Date: January 2018 Void After: January Product: Fill Valves (Anti-Siphon) File No. 3733 IAPMO Research and Testing, Inc. is a product certification body which tests and inspects samples taken from the supplier's stock or from the market or a combination of both to verify compliance to the

More information

Effective Date: April 2018 Void After: April 2019

Effective Date: April 2018 Void After: April 2019 IAPMO Research and Testing, Inc. is a product certification body which tests and inspects samples taken from the supplier's stock or from the market or a combination of both to verify compliance to the

More information

Effective Date: May 2017 Void After: May Product: Press and Nail Connections File No. M-8332

Effective Date: May 2017 Void After: May Product: Press and Nail Connections File No. M-8332 IAPMO Research and Testing, Inc. is a product certification body which tests and inspects samples taken from the supplier's stock or from the market or a combination of both to verify compliance to the

More information

Effective Date: not available -Rev. 12/1/2017- Void After: Product: Water Closets with Dual Flush Feature File No. 5645

Effective Date: not available -Rev. 12/1/2017- Void After: Product: Water Closets with Dual Flush Feature File No. 5645 IAPMO Research and Testing, Inc. is a product certification body which tests and inspects samples taken from the supplier's stock or from the market or a combination of both to verify compliance to the

More information

Effective Date: December 2017 Void After: December 2018

Effective Date: December 2017 Void After: December 2018 IAPMO Research and Testing, Inc. is a product certification body which tests and inspects samples taken from the supplier's stock or from the market or a combination of both to verify compliance to the

More information

Effective Date: February 2018 Void After: February Product: Bathtubs (Plastic) File No. 3638

Effective Date: February 2018 Void After: February Product: Bathtubs (Plastic) File No. 3638 IAPMO Research and Testing, Inc. is a product certification body which tests and inspects samples taken from the supplier's stock or from the market or a combination of both to verify compliance to the

More information

Effective Date: October 2017 Void After: October Product: Ceramic Plumbing Fixtures File No. 2467

Effective Date: October 2017 Void After: October Product: Ceramic Plumbing Fixtures File No. 2467 IAPMO Research and Testing, Inc. is a product certification body which tests and inspects samples taken from the supplier's stock or from the market or a combination of both to verify compliance to the

More information

Installation Instructions

Installation Instructions Installation Instructions COLONY SOFT 7.0 Centerset Lavatory Faucet 7.0 with Speed Connect Drain Congratulations on purchasing your American Standard faucet with the Speed Connect drain, a features found

More information

CROSS REFERENCE PARTS LIST T & S

CROSS REFERENCE PARTS LIST T & S 002711-40 KL41-Y006-KT Cold Spindle Assembly 002712-40 KL41-Y007-KT Hot Spindle Assembly 004R K50-Y011 Finger Hook Assembly 005312-40 KL50-Y027 Pedal Valve Bonnet Assembly 006678-45 K30-1000 Dipperwell

More information

Suction fittings for use in swimming pools, wading pools, spas, hot tubs, and other aquatic facilities.

Suction fittings for use in swimming pools, wading pools, spas, hot tubs, and other aquatic facilities. IAPMO Research and Testing, Inc. is a product certification body which tests and inspects samples taken from the supplier's stock or from the market or a combination of both to verify compliance to the

More information

Decorative Accessories Guide

Decorative Accessories Guide Decorative Accessories Guide Monogram Brass is a trademark of Ferguson Enterprises, Inc. Monogram Brass Finishes Brushed Nickel* (BN) Oil Rubbed Bronze (ORB) Polished Brass* (PB) Chrome (CP) Biscuit (BISC)

More information

Decorative Accessories Guide

Decorative Accessories Guide Decorative Accessories Guide Monogram Brass is a trademark of Ferguson Enterprises, Inc. Monogram Brass Finishes Brushed Nickel* (BN) Oil Rubbed Bronze (ORB) Polished Brass* (PB) Chrome (CP) Biscuit (BISC)

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS EDGEMERE CENTERSET LAVATORY FAUCET INSTALLATION INSTRUCTIONS 708.0 Thank you for selecting American Standard... the benchmark of fine quality for over 00 years. To ensure that your installation proceeds

More information

table of contents bath accessories Cable Drains...19 Cover Plates Drains Drain Conversion Kits...20

table of contents bath accessories Cable Drains...19 Cover Plates Drains Drain Conversion Kits...20 table of contents kitchen accessories Air Gaps.............3 Basket Strainers.........3 Disposal Flanges....... 3-4 Faucet Hole Covers....... 4 Soap & Lotion Dispensers.... 4 Water Dispensers........ 4

More information

Effective Date: July 2016 Void After: July Product: ABS-DWV Pipe and Fittings File No. 9266

Effective Date: July 2016 Void After: July Product: ABS-DWV Pipe and Fittings File No. 9266 IAPMO Research and Testing, Inc. is a product certification body which tests and inspects samples taken from the supplier's stock or from the market or a combination of both to verify compliance to the

More information

Effective Date: July 2018 Void After: July Product: Plumbing Fixture Fittings File No. 4155

Effective Date: July 2018 Void After: July Product: Plumbing Fixture Fittings File No. 4155 IAPMO Researh and Testing, In. is a produt ertifiation body whih tests and inspets samples taken from the supplier's stok or from the market or a ombination of both to verify ompliane to the requirements

More information

California Lead Plumbing Law Devices and Components

California Lead Plumbing Law Devices and Components IAPMO Research and Testing, Inc. is a product certification body which tests and inspects samples taken from the supplier's stock or from the market or a combination of both to verify compliance to the

More information

Brass Tubular. P-Traps. Item # Description Qty

Brass Tubular. P-Traps. Item # Description Qty B r a s s T u b u l a r P-Traps 1 1-1/4 17 ga CP P-Trap 1B with brass nuts 1D with box flange 1BD with box flange and brass nuts 115 with 15 wall bend 1B15 with 15 wall bend and brass nuts 1D15 with 15

More information

Engineering Excellence. Installation Guide

Engineering Excellence. Installation Guide Engineering Excellence Installation Guide Two Handle Kitchen Faucet: 2DM200 2DM201 This product meets the following standards: ASME A112.18.1 ANSI A117.1 ANSI / NSF 61, SECTION 9 CUPC / IAPMO LISTED /

More information

THE KEENEY MANUFACTURING COMPANY

THE KEENEY MANUFACTURING COMPANY Brass Tubular P Traps 1-8 Repair Traps 8-9 S Traps 9-11 Sink Traps 11-15 Bath Traps 15 Washing Machine Traps 16 J Bends 16-17 Sink Trap J Bends 17-18 Wall Bends 19 Floor Tubes 19 Center Outlet Continuous

More information

sensible sophistication

sensible sophistication d e s i g n e r f a u c e t s & a c c e s s o r i e s sensible sophistication A rare collection of artistic expressions for the distinctive home environment. Mirabelle is a fusion of form, craftsmanship

More information

MIDDLESEX COUNTY COLLEGE EDISON, NJ LOCAL SUPPLIER BLANKET ORDER SPECIFICATIONS

MIDDLESEX COUNTY COLLEGE EDISON, NJ LOCAL SUPPLIER BLANKET ORDER SPECIFICATIONS MIDDLESEX COUNTY COLLEGE EDISON, NJ 08818 LOCAL SUPPLIER BLANKET ORDER SPECIFICATIONS The College is soliciting bids to award a Local Supplier Blanket Order agreement for the purchase of supplies for the

More information

DESIGNER FAUCETS & ACCESSORIES

DESIGNER FAUCETS & ACCESSORIES DESIGNER FAUCETS & ACCESSORIES sensible sophistication A rare collection of artistic expressions for the distinctive home environment. Mirabelle is a fusion of form, craftsmanship and function designed

More information

ADA STANDARD OVERVIEW AND SPEAKMAN APPLICABLE PRODUCTS

ADA STANDARD OVERVIEW AND SPEAKMAN APPLICABLE PRODUCTS ADA STANDARD OVERVIEW AND SPEAKMAN APPLICABLE PRODUCTS ADA PRODUCT TRAINING PG. 1 Specs are for reference only. Please refer ADA.gov for the latest requirements. ADA What is the Americans with Disabilities

More information

Owners Manual. Models 4420BF1U & 4420BF1L Floor Mounted Bi-Level Bottle Filler Tubular Fountain

Owners Manual. Models 4420BF1U & 4420BF1L Floor Mounted Bi-Level Bottle Filler Tubular Fountain Owners Manual Models 4420BF1U & 4420BF1L Floor Mounted Bi-Level Bottle Filler Tubular Fountain Models (LK)4420BF1U* Models (LK)4420BF1L* INSTALLER 4420BF Fountains are among the easiest to install Fountains

More information

EVALUATION SUBJECT: CAST IRON SOIL PIPE AND FITTINGS DIVISION: PLUMBING SECTION: SANITARY WASTE AND VENT PIPING.

EVALUATION SUBJECT: CAST IRON SOIL PIPE AND FITTINGS DIVISION: PLUMBING SECTION: SANITARY WASTE AND VENT PIPING. ICC-ES Report PMG-1407 Reissued 10/2017 This report is subject to renewal 10/2018 EVALUATION SUBJECT: CAST IRON SOIL PIPE AND FITTINGS DIVISION: 22 00 00 PLUMBING SECTION: 22 13 16 SANITARY WASTE AND VENT

More information

Installation Instructions

Installation Instructions Installation Instructions COLONY SOFT 7.0 Single Control Lavatory Faucet with Speed Connect Drain Congratulations on purchasing your American Standard faucet with the Speed Connect drain, a feature found

More information

Piece Weight. List Price. Basket Strainer-Plastic. Wash Tray Plug. TIP TOE Tub Drain. Shower Drain Grids

Piece Weight. List Price. Basket Strainer-Plastic. Wash Tray Plug. TIP TOE Tub Drain. Shower Drain Grids PLUMBING SPECIALTIES PS_1018 EFFECTIVE OCTOBER 1, 2018 (SUPERCEDES PS_0918) The issuance of this price list is not an offer to sell the goods listed herein at the prices stated. Bath Coupling Elbow 123-096

More information

Latvin Luxury Shower Panel. Telephone Product Specification. ~ Minimum Working Pressure 1.0 bar ~ Maximum Working Pressure 3.

Latvin Luxury Shower Panel. Telephone Product Specification. ~ Minimum Working Pressure 1.0 bar ~ Maximum Working Pressure 3. Product Specification ~ Minimum Working Pressure 1.0 bar ~ Maximum Working Pressure 3.0 bar Latvin Luxury Shower Panel ~ Fixing Centres 150mm +/- 10mm ~ Outlet size 1/2" Bottom Outlet Always maintain a

More information

Model MTB-ASME Vertical Bladder Tanks

Model MTB-ASME Vertical Bladder Tanks DATA SHEET Model MTB-ASME Vertical Bladder Tanks Features n UL Listed for use with various proportioners and foam concentrates n 175 psi (12.1 bar) maximum allowable working pressure (design pressure)

More information

Model MTB-ASME Vertical Bladder Tanks

Model MTB-ASME Vertical Bladder Tanks DATA SHEET Model MTB-ASME Vertical Bladder Tanks Features n UL Listed for use with various proportioners and foam concentrates n 175 psi (12.1 bar) maximum allowable working pressure (design pressure)

More information

CONNECTION SYSTEM Includes Push-Fit and Barb Products and PEX Tubing

CONNECTION SYSTEM Includes Push-Fit and Barb Products and PEX Tubing 1 1-877-700-4242 1-877-700-4242 The CONNECTION SYSTEM Includes Push-Fit and Barb Products and PEX Tubing Contents Introduction 2-3 Push-Fit Fittings 4-6 Stops and Fixture Supply Fittings 7 Push-Fitting

More information

AKIT1901LM (Metal levers) AKIT1901XM (Cross Handles)

AKIT1901LM (Metal levers) AKIT1901XM (Cross Handles) PALLADIAN EXPOSED TUB SET WITH HANDSHOWER AKIT1901LM (Metal levers) AKIT1901XM (Cross Handles) COLORS/FINISHES WARRANTY FEATURES Palladian metal levers or cross handles Floor mounted exposed two handle

More information

THE PERFECT PRESSURE DROP TRAP PRIMER

THE PERFECT PRESSURE DROP TRAP PRIMER THE PERFECT PRESSURE DROP TRAP PRIMER FIGURE NO. 2694 PATENT NO. 9,708,808 Regularly furnished in Lead-Free Brass as shown (back). Optional finishes available in Chrome (front), Nickel, or Stainless Steel

More information

Horizontal Bladder Tanks

Horizontal Bladder Tanks DATA SHEET Horizontal Bladder Tanks Features UL Listed and FM Approved for use with various ANSUL proportioners and foam concentrates 175 psi (12.1 bar) maximum allowable working pressure (design pressure)

More information

Vertical Bladder Tanks

Vertical Bladder Tanks DATA SHEET Vertical Bladder Tanks Features UL Listed and FM Approved for use with various ANSUL proportioners and foam concentrates 175 psi (12.1 bar) maximum allowable working pressure (design pressure)

More information

Service Sink Faucets

Service Sink Faucets Service Sink Faucets Heavy-Duty Service Fittings Faucets in janitorial and maintenance sink locations are subjected to more abuse than any other faucet in your facility. Their exposure to chemicals and

More information

Model MTB-ASME Horizontal Bladder Tanks

Model MTB-ASME Horizontal Bladder Tanks DATA SHEET Model MTB-ASME Horizontal Bladder Tanks Features n UL Listed and FM Approved for use with various proportioners and foam concentrates n 175 psi (12.1 bar) maximum allowable working pressure

More information

Water Hammer Arrestors

Water Hammer Arrestors Water Hammer rrestors watts.com What is Water Hammer? T he noise from banging pipes is caused by shocks of high speed water flowing in the piping system when a fixture is suddenly closed. Sudden stoppage

More information

Twin & Triple Control Concealed Thermostatic Shower Valve

Twin & Triple Control Concealed Thermostatic Shower Valve Twin & Triple Control Concealed Thermostatic Shower Valve Installation & Operating Guide Please leave this installation & user guide with the end user CONTENTS: 1. Introduction & Safety 1 2. Dimensions

More information

Kitchen Price List N O R T H A M E R I C A

Kitchen Price List N O R T H A M E R I C A Kitchen Price List N O R T H A M E R I C A Kitchen Price List N O R T H A M E R I C A [2] numerical price index CODE FINISH DESCRIPTION PRICE LIST PAGE CERTIFICATION TIME LINE AND STATUS 915 915 920 920

More information

PRO SINK -R 1 and 2. Dilution system CONTENTS

PRO SINK -R 1 and 2. Dilution system CONTENTS PRO SINK -R 1 and 2 Dilution system CONTENTS 1.0 Product description 2 2.0 Warnings.. 3 3.0 Installation procedure 4 4.0 Plumbing connections 4 5.0 Technical features.. 5 6.0 Maintenance... 6 7.0 Troubleshooting......6

More information

WaterSource Heat Pump Hose Kit Performance Specification-Summary

WaterSource Heat Pump Hose Kit Performance Specification-Summary WaterSource Heat Pump Hose Kit Performance Specification-Summary AUTOMATIC & MANUAL BALANCING HOSE KITS Contractor shall provide and install Hays Hose Kits. Each kit, shall include a Hays 2500 Series Mesurflo

More information

Summary of Substantive Changes between the 2012 and 2018 editions of CSA B125.3 Plumbing Fittings

Summary of Substantive Changes between the 2012 and 2018 editions of CSA B125.3 Plumbing Fittings Summary of Substantive Changes between the 2012 and 2018 editions of CSA B125.3 Plumbing Fittings Presented to the IAPMO Standards Review Committee on October 15, 2018 General: The changes to this standard

More information

MUELLER. A Wall Type. Indicator Post. Reliable Connections. General Information 2. Technical Data/ Dimensions 3. Installation 4-5.

MUELLER. A Wall Type. Indicator Post. Reliable Connections. General Information 2. Technical Data/ Dimensions 3. Installation 4-5. Installation Instructions manual MUELLER table of contents PAGE A-20814 Wall Type General Information 2 Technical Data/ Dimensions Installation 4-5 Maintenance 6 Parts 7 Indicator Post! WARNING: 1. Read

More information

Water Temperature Control - Groups of Fixtures

Water Temperature Control - Groups of Fixtures Digital - Outlook ASSE 1070 Certified Up to six outlets from a single valve Programmable timed flow (independent for each outlet) On/Off or preset timed flow control with either touch or no touch sensors

More information

SABERINDO PACIF SABERINDO PACIFIC CIFIC SABERINDO PA. A Tyco International Company

SABERINDO PACIF SABERINDO PACIFIC CIFIC SABERINDO PA. A Tyco International Company CIF A Tyco International Company 1 Foam Concentrate CIF 3% AFFF -UL Listed -UL Canada Listed 6% AFFF 6 parts AFFF concentrate to 94 parts water -UL Listed- Foam Liquid -UL Canada Listed 3% FLUOROPROTEIN

More information

SOLUTION ASTM F1960. Sioux Chief Tubing. Mr. PEX Tubing. Sioux Chief PowerPEX. Wolverine Brass WOLV-XPEX. Milwaukee Expansion Tools

SOLUTION ASTM F1960. Sioux Chief Tubing. Mr. PEX Tubing. Sioux Chief PowerPEX. Wolverine Brass WOLV-XPEX. Milwaukee Expansion Tools ASTM SOLUTION Sioux Chief Tubing Mr. PEX Tubing Sioux Chief PowerPEX Wolverine Brass WOLV-XPEX Milwaukee Expansion Tools Phone: 1-800-523-5130 Fax: 1-800-338-1867 www.plumbmaster.com Phone: 1-800-944-9292

More information

Effective Date: October Rev. 1/29/2018- Void After: October Product: Lead Free Plumbing Products File No. 6544

Effective Date: October Rev. 1/29/2018- Void After: October Product: Lead Free Plumbing Products File No. 6544 IAPMO Research and Testing, Inc. is a product certification body which tests and inspects samples taken from the supplier's stock or from the market or a combination of both to verify compliance to the

More information

HORIZONTAL BLADDER TANK

HORIZONTAL BLADDER TANK Balanced Pressure Proportioning System Reliable Foam System Requiring Only Water Power Perfect For Low Ceilings UL Listed, ASME, National Board Registered Bladder-UL162 Approved, High Tensile Pressure

More information

Product Catalogue. February We mean progress. PEX plumbing Fire safety Hydronic piping Radiant heating and cooling Pre-insulated piping

Product Catalogue. February We mean progress. PEX plumbing Fire safety Hydronic piping Radiant heating and cooling Pre-insulated piping Product Catalogue February 2019 PEX plumbing Fire safety Hydronic piping Radiant heating and cooling Pre-insulated piping We mean progress. Table of contents Table of contents 1 Uponor Design Services

More information

TECHNICAL DATA. Trimpac 244a. September 16, 2013

TECHNICAL DATA. Trimpac 244a. September 16, 2013 September 16, 2013 Trimpac 244a 1. DEsCrIpTION DESCRIPTION TRIMPAC Model B-1 and B-1B is a factory-assembled trim package with an electric release module in a metal enclosure. The standard trim normally

More information

VERTICAL BLADDER TANK

VERTICAL BLADDER TANK Balanced Pressure Proportioning System Reliable Foam System Requiring Only Water Power Perfect For Tight Spaces UL Listed, ASME, National Board Registered Bladder-UL162 Approved, High Tensile Pressure

More information

Operators Manual. Supera Wall Mount Anesthesia Machines. Models: M2300 M2500. (All shown with optional equipment) M2300 M2500

Operators Manual. Supera Wall Mount Anesthesia Machines. Models: M2300 M2500. (All shown with optional equipment) M2300 M2500 Operators Manual Supera Wall Mount Anesthesia Machines Models: M2300 M2500 (All shown with optional equipment) M2300 M2500 Examination and Preparation for Use Thank you for ordering an Supera Anesthesia

More information

Pressure Independent Control Series

Pressure Independent Control Series Document No. 155-522 Pressure Independent Control Series Two-Way Cast Iron Flanged Bodies, ANSI 125 and 250 Description Siemens Pressure Independent Control Valves integrate three functions into a single

More information

Heavy Duty Commercial Supply Stops

Heavy Duty Commercial Supply Stops Heavy Duty Commercial Supply Stops Designing the best stop valve solutions for 100 years. 1/4-Turn Ball Valve 1/4 Turn Ball Valve In 1914, Chicago Faucets developed its first stop valve the A-1200. Over

More information

BASIN AND WALL MIXER INSTALLATION INSTRUCTIONS

BASIN AND WALL MIXER INSTALLATION INSTRUCTIONS BASIN AND WALL MIXER INSTALLATION INSTRUCTIONS IMPORTANT INFORMATION IMPORTANT All tapware and showers to be installed by a licensed plumber and to Australian Standards. Fit tempering and pressure reduction

More information

U.KIT3L (Lever Handles) U.KIT3X (Cross Handles)

U.KIT3L (Lever Handles) U.KIT3X (Cross Handles) PERRIN & ROWE EDWARDIAN EXPOSED SHOWER PACKAGE WITH TUB SPOUT Perrin & Rowe Bath U.KIT3L (Lever Handles) U.KIT3X (Cross Handles) FEATURES COLORS/FINISHES WARRANTY Shower package components: - U.5550L or

More information

PRESSURE, VACUUM AND TEMPERATURE

PRESSURE, VACUUM AND TEMPERATURE 5 4 S er i es 5 4 Se r i e s PRESSURE, VACUUM AND TEMPERATURE features Compact Size Wide Selection of Adjustable Ranges: Pressure: 30 Hg Vac to 6000 psi (-1 to 413,7 bar) Temperature: -130 to 650 F (-90

More information

Effective Date: February Rev. 7/13/2018- Void After: February Product: Plumbing Fixtures (Stainless Steel) File No.

Effective Date: February Rev. 7/13/2018- Void After: February Product: Plumbing Fixtures (Stainless Steel) File No. IAPMO Research and Testing, Inc. is a product certification body which tests and inspects samples taken from the supplier's stock or from the market or a combination of both to verify compliance to the

More information

Wet pipe low flow foam/water system

Wet pipe low flow foam/water system December 6, 2010 Foam 14a 1. The Viking Low Flow Foam/Water proportioning system, is a UL Listed and FM Approved system, for use with Viking supplied foam concentrates. This system consists of a standard

More information

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B September 16, 2013 Trimpac 250a 1. DESCRIPTION DEsCRIPTIoN is a factory assembled trim package for a ed an electric/pneumatic release module in a metal enclosure. The standard trim normally required on

More information

GAS DISTRIBUTION PRODUCTS TRANSITION FITTINGS

GAS DISTRIBUTION PRODUCTS TRANSITION FITTINGS GAS DISTRIBUTION PRODUCTS TRANSITION FITTINGS CONTINENTAL INDUSTRIES, INC. The Ultimate Connection CONTINENTAL INDUSTRIES, INC. ABOUT US THE ULTIMATE CONNECTION Our Company Continental Industries, Inc.,

More information

PLUMBING WATER & GAS TRADE CATALOGUE

PLUMBING WATER & GAS TRADE CATALOGUE PLUMBING WATER & GAS TRADE CATALOGUE 2015 Index Plumbing, Water & Gas Hoses & Fillers P-04 Tanks Containers Accessories P-07 PumpsP-11 Water is our most precious resource and a necessity when camping and

More information

SUPPLY OF ISOLATION AND APPLIANCE VALVES PTS - APPLIANCE BALL VALVE

SUPPLY OF ISOLATION AND APPLIANCE VALVES PTS - APPLIANCE BALL VALVE PTS - APPLIANCE BALL VALVE 2 30.06.17 Issued for Tender AS ADE GS 1 12.04.17 Issued for Tender AS AD GS 0 06.03.17 Issued for Client s Comments AS AD GS Rev. Date Subject of revision Author Checked Approved

More information

Installation Instructions

Installation Instructions LP and High Altitude LP Gas Conversion Kit For United States Installations Installation Instructions For Model Series *G6/PGF1 Furnaces, *L1/PGC1 Furnaces, and *R4/PPG1 Gas/Electric Appliances using Honeywell

More information

TECHNICAL DATA. Trimpac 251a. Spetember 16, 2013

TECHNICAL DATA. Trimpac 251a. Spetember 16, 2013 Spetember 16, 2013 Trimpac 251a 1. DEsCrIpTION DESCRIPTION TRIMPAC Model B-6 and B-6B is a factory assembled trim package for a double interlocked preaction system with an electric/pneu-lectric release

More information

D. ACCESSORIES ADAPTER KITS IMPELLER & SEAL INSTALLATION TOOLS CARRYING HANDLES & LIFT CORDS GALVANIC PROTECTION KITS MUSHROOM STRAINER

D. ACCESSORIES ADAPTER KITS IMPELLER & SEAL INSTALLATION TOOLS CARRYING HANDLES & LIFT CORDS GALVANIC PROTECTION KITS MUSHROOM STRAINER . ACCESSORIES AAPTER KITS IMPELLER & SEAL INSTALLATION TOOLS CARRYING HANLES & LIFT CORS GALVANIC PROTECTION KITS MUSHROOM STRAINER SLUGE STRAINERS NEMA 4 WATERTIGHT CONTROL & UAL LEVEL CONTROL (Replaces

More information

MIDDLESEX COUNTY COLLEGE EDISON, NJ LOCAL SUPPLIER BLANKET ORDER SPECIFICATIONS

MIDDLESEX COUNTY COLLEGE EDISON, NJ LOCAL SUPPLIER BLANKET ORDER SPECIFICATIONS MIDDLESEX COUNTY COLLEGE EDISON, NJ 08818 LOCAL SUPPLIER BLANKET ORDER SPECIFICATIONS The College is soliciting bids to award a Local Supplier Blanket Order agreement for the purchase of supplies for the

More information

FIRE PROTECTION PRODUCTS

FIRE PROTECTION PRODUCTS AGF Manufacturing Inc. FIRE PROTECTION PRODUCTS PRODUCT CATALOG CAT-AGF_V002 1/15 Reliability, Versatility, Code Compatibility AGF Product Catalog Table of Contents COLLECTa ndrain Auxiliary Drains Model

More information

FM Approved - Automatic Water Control Valve as standard deluge valve. No formal approval available for coating. Foam Concentrate

FM Approved - Automatic Water Control Valve as standard deluge valve. No formal approval available for coating. Foam Concentrate December 6, 2010 Foam 21a 1. Description With Multiple Foam/Water Deluge Systems Supplied by a Bladder Tank, multiple deluge foam risers can be supplied from a single foam concentrate source. Where a bladder

More information

INSTALLATION INSTRUCTIONS MANUAL ON/OFF SAFETY VALVE/PILOT KIT MODEL GA9050A-1 (F0235)

INSTALLATION INSTRUCTIONS MANUAL ON/OFF SAFETY VALVE/PILOT KIT MODEL GA9050A-1 (F0235) P/N 126905-01 Rev. B 11/2016 INSTALLATION INSTRUCTIONS MANUAL ON/OFF SAFETY VALVE/PILOT KIT MODEL GA9050A-1 (F0235) For All Single, Dual and Triple Burner Natural and Propane/LP Gas Logs P126905-01 For

More information

REGULATORS FLOWMETERS HUMIDIFIERS. Professional GAUGES ASSESSORIES. Medical Apparatus. and Assessories ISO 13485/ISO 9001 CERTIFICATION

REGULATORS FLOWMETERS HUMIDIFIERS. Professional GAUGES ASSESSORIES. Medical Apparatus. and Assessories ISO 13485/ISO 9001 CERTIFICATION Medical Apparatus REGULATORS FLOWMETERS Professional Medical Apparatus and Assessories HUMIDIFIERS GAUGES ASSESSORIES ISO 13485/ISO 9001 CERTIFICATION Company Profile MORRIS ENGINEERING WORKS LTD. was

More information

TECHNICAL DATA. than the water inlet pressure to the concentrate

TECHNICAL DATA. than the water inlet pressure to the concentrate Foam102a 1. DESCRIPTION The Viking Low Flow Foam/Water proportioning system, is a UL Listed and FM Approved system, for use with 3M foam concentrates. This system consists of a standard wet pipe sprinkler

More information

TECHNICAL DATA. Trimpac 257a. September 16, 2013

TECHNICAL DATA. Trimpac 257a. September 16, 2013 September 16, 2013 Trimpac 257a 1. DESCrIpTION DESCRIPTION The Viking Double SUREFIRE SIngle Interlock Preaction TRIMPAC Model D-2 and D-2B used with either a Model E or F Deluge Valve (A.1), a Viking

More information

appendix a recommended rules For sizing the water supply system PRE-PRINT Chart a 1.2 FriCtion losses For Disk-type water Meters

appendix a recommended rules For sizing the water supply system PRE-PRINT Chart a 1.2 FriCtion losses For Disk-type water Meters recommended rules For sizing the water supply system Because of the variable conditions encountered, it is impractical to lay down definite detailed rules of procedure for determining the sizes of water

More information

Presented to the IAPMO Standards Review Committee on March 7, 2016

Presented to the IAPMO Standards Review Committee on March 7, 2016 Summary of Substantive Changes between the 2015 edition of ASSE 1070/ASME A112.1070/CSA B125.70, Water Temperature Limiting Devices, the 2004 edition of ASSE 1070, Water Temperature Limiting Devices, and

More information

Installation/Care/Use Manual

Installation/Care/Use Manual Installation/Care/Use Manual EMASM Surface Mount Bottle Filling Station IMPORTANT THIS IS AN INDOOR APPLICATION ONLY! ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSONNEL. TOOLS/ITEMS REQUIRED

More information

Laars Combi Heat PV Gas Water Heater

Laars Combi Heat PV Gas Water Heater RESIDENTIAL GAS REPLACEMENT PARTS LIST Laars Combi Heat PV Gas Water Heater Document 11040 Effective: September, 2006 ECO 6885 NOTE: BOTH MODEL AND SERIAL NUMBERS ARE REQUIRED FOR ORDERING REPLACEMENTS

More information

Crest Heating Boilers FBN(L) Series &

Crest Heating Boilers FBN(L) Series & Replacement Parts List PARTS & SERVICE DEPARTMENT Nashville, Tennessee 877-554-5544 Fax: 615-882-2918 parts_team@lochinvar.com www.lochinvar.com Crest Heating Boilers FBN(L) 751-2001 Series 100-101 & 110-111

More information

INSTRUCTION MANUAL. Gas Salamander

INSTRUCTION MANUAL. Gas Salamander INSTRUCTION MANUAL Gas Salamander This manual contains important information regarding your unit. Please read this manual thoroughly prior to equipment set-up, operation and maintenance. Failure to comply

More information

Self-help Temperature Adjustment

Self-help Temperature Adjustment Self-help Temperature Adjustment The Shower Valve temperature is pre-set to 42 C, but on certain installations the temperature may need to be adjusted. Note: The hot water supply must be above 60 C. Turn

More information

Your safety and the safety of others are very important.

Your safety and the safety of others are very important. NATURAL GAS TO PROPANE CONVERSION KIT ALPKT57- INSTALLATION INSTRUCTIONS PROPANE CONVERSION KIT SAFETY... INSTALLATION REQUIREMENTS... Tools and Parts... LP Gas Requirements... Table of Contents INSTALLATION

More information

Product Catalogue. July We mean progress. PEX plumbing Fire safety Hydronic piping Radiant heating and cooling Pre-insulated piping

Product Catalogue. July We mean progress. PEX plumbing Fire safety Hydronic piping Radiant heating and cooling Pre-insulated piping Product Catalogue July 2018 PEX plumbing Fire safety Hydronic piping Radiant heating and cooling Pre-insulated piping We mean progress. Table of contents Table of contents 1 Uponor Design Services and

More information

TECHNICAL DATA. Low-Flow Foam Preaction System with Hydraulically Actuated Concentrate Control Valve.

TECHNICAL DATA. Low-Flow Foam Preaction System with Hydraulically Actuated Concentrate Control Valve. Foam 302 a 1. DESCRIPTION (Refer to Figure 1 on page 302 e.) The Viking Low-Flow Foam/Water Proportioning System is a UL Listed and FM Approved system, for use with 3M and Viking brand foam concentrate.

More information

Halsey Taylor Owners Manual

Halsey Taylor Owners Manual Halsey Taylor Owners Manual Wall Mount Steel Refrigerated Fountains INSTALLER These series fountains are among the easiest to install Fountains on the market today. To assure you install these models easily

More information

FM Approved - Automatic Water Control Valve as standard deluge valve. No formal approval available for coating. Foam Concentrate

FM Approved - Automatic Water Control Valve as standard deluge valve. No formal approval available for coating. Foam Concentrate December 6, 2010 Foam 31a 1. Description With Multiple Pilot Pressure Regulating Foam/Water Deluge Systems Supplied by a Bladder Tank, multiple pilot pressure regulating foam risers can be supplied from

More information

MDX² INSTALLATION MANUAL (RETROFIT FIBERGLASS, VINYL & CONCRETE POOLS WITH MDX)

MDX² INSTALLATION MANUAL (RETROFIT FIBERGLASS, VINYL & CONCRETE POOLS WITH MDX) Only for Pools with an existing MDX sump ANTI-ENTRAPMENT DEBRIS DRAIN MDX² INSTALLATION MANUAL (RETROFIT FIBERGLASS, VINYL & CONCRETE POOLS WITH MDX) Safety compliant according to the Virginia Graeme Baker

More information

OBSOLETE. Wet pipe low flow manifold system

OBSOLETE. Wet pipe low flow manifold system June 1, 2008 Foam 15a 1. Description Multiple risers can be supplied from a single proportioning device. A riser manifold is installed with various riser types and sizes that are to supply foam solution

More information

Recommended Retail Price List

Recommended Retail Price List Hansgrohe P ty Ltd 1/ 123 Cam berwell Rd East Hawthorn 3123 Australia Tel: 03 9811 9971 P a g e 1 Recommended Retail Price List Effective December 2017 Hansgrohe P ty Ltd 1/ 123 Cam berwell Rd East Hawthorn

More information

PRESSURE REGULATORS AND FLOWMETERS, ALL MEDICAL GASES

PRESSURE REGULATORS AND FLOWMETERS, ALL MEDICAL GASES PRESSURE REGULATORS ALL MEDICAL GASES In this section we propose our pressure regulators (FM series, MU and MERCURY ) and our Rs flowmeters for applications other than oxygen therapy (presented in the

More information

Chrome plated radiator valves type RA-NCX and lockshield valves type RLV-CX

Chrome plated radiator valves type RA-NCX and lockshield valves type RLV-CX Chrome plated radiator valves type RA-NCX and lockshield valves type RLV-CX Application RA-NCX angle RA-NCX straight RA-NCX left angle RLV-CX straight RLV-CX angle RA-NCX and RLV-CX is a series of chrome

More information

RELIABLE PROTECTION FOR A WIDE RANGE OF RESIDENTIAL, COMMERCIAL AND INDUSTRIAL APPLICATIONS. water pressure reducing valves

RELIABLE PROTECTION FOR A WIDE RANGE OF RESIDENTIAL, COMMERCIAL AND INDUSTRIAL APPLICATIONS. water pressure reducing valves RELIABLE PROTECTION FOR A WIDE RANGE OF RESIDENTIAL, COMMERCIAL AND INDUSTRIAL APPLICATIONS water pressure reducing valves Table of Contents Product...Page How Pressure Reducing Valves Work...3 36 Series...

More information

TECHNICAL DATA. Trimpac 256a. October 31, 2013

TECHNICAL DATA. Trimpac 256a. October 31, 2013 October 31, 2013 Trimpac 256a 1. DESCRIPTION The Viking SUREFIRE SIngle Interlock Preaction TRIMPAC Model D-1 and D- 1B used with either a Model E or F Deluge Valve (A.1), a Viking Easy Riser check valve

More information

MUELLER A A Non-Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.

MUELLER A A Non-Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3. Installation Instructions manual MUELLER table of contents PAGE A-20808 General Information 2 Technical Data 3 Dimensions 4 A-20809 Non-Adjustable Installation 5-6 Parts 7 Maintenance 8 Vertical Indicator

More information

G92 Series BASOTROL Automatic Pilot Gas Valve

G92 Series BASOTROL Automatic Pilot Gas Valve Installation Instructions Issue Date September 17, 2008 G92 Series BASOTROL Automatic Pilot Gas Valve Installation IMPORTANT: Only qualified personnel should install or service BASO Gas Products. These

More information

Model PDT Dewpoint Transmitter

Model PDT Dewpoint Transmitter Model PDT Dewpoint Transmitter Instruction Manual Alpha Moisture Systems Alpha House 96 City Road Bradford BD8 8ES England Tel: +44 1274 733100 Fax: +44 1274 733200 email: mail@amsytems.co.uk web: www.amsystems.co.uk

More information

American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM

American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM ASSE STANDARD #1019 - REVISED: 2011 Wall Hydrant with Backflow Protection and Freeze Resistance MANUFACTURER: CONTACT PERSON: E-MAIL:

More information

FITTINGS THREAD LUBRICANTS. Fittings 20,000 PSI

FITTINGS THREAD LUBRICANTS. Fittings 20,000 PSI Jetstream offers a wide variety of fittings with various connection types to fit your 20,000 psi application needs. The standard connection types, Type M, MP, and MP Tube lance, are available in standard

More information

Aquor House Hydrant V2

Aquor House Hydrant V2 Aquor House Hydrant V2 IN-WALL OUTDOOR FAUCET SYSTEM FLUSH-MOUNT QUICK-CONNECT SELF-DRAINING ANTI-SIPHON NON-FREEZE VBH-SERIES AQUOR HOUSE HYDRANT V2: WALL HYDRANT / FREEZELESS SILLCOCK Freezeless sillcock

More information