Certificate of Approval. No 5/6B/211

Similar documents
Supplementary Certificate of Approval. No S433

EC type-examination certificate UK/0126/0065 Revision 1

United Kingdom of Great Britain and Northern Ireland

United Kingdom of Great Britain and Northern Ireland

Compiled by: B Beard. Approved by: SH Carstens. Description of requirements and procedures for compact provers to be used as verification standards.

pren CEN standard-draft pr EN 12261

Vehicle-mounted meters, pump supplied

INTERNATIONAL OIML R 32 RECOMMENDATION. Rotary piston gas meters and turbine gas meters ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION

InnoVfoam B.V. InnovDos Foam Proportioning System

Vehicle- or rack-mounted liquefied gas meters, pump supplied

InnovDos Foam proportioning system

SINGLE VALVE WITH LOW-FLOW BYPASS

Mass Flow Controller (MFC) for Gases

TRZ 03-K Volumeter. Proven Technology. Superior Performance. TRZ 03-K Volumeter is a Turbine Gas Flowmeter for Secondary Gas Metering.

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301

Mass Flow Meter (MFM) for Gases

Liquid ring vacuum pumps in compact design

Mass Flow Controller (MFC) for Gases

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10

OIL SUPPLY SYSTEMS ABOVE 45kW OUTPUT 4.1 Oil Supply

Guideline No.M-05(201510) M-05 AIR COMPRESSOR. Issued date: 20 October China Classification Society

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

Centrifugal Gas Separator ZGA. Operating Manual. Dimensions, weights and other technical data are subject to changes.

G96 Series BASOTROL Dual Operator Valve

WATER METERS.

PROCESS ROTATING EQUIPMENT (CENTRIFUGAL PUMPS )

On-Off switch. Selectable manual control for commissioning. Remote start input for control via an irrigation controller, or external sensor.

Design. Pompetravaini-NSB API SB Liquid Ring Compressor for Gas Processing. Working Principle

Displacement. from 2 up to 6 sections balanced, unbalanced from 0.8 to 31 ccm FLOW DIVIDERS

Integral type Differential pressure flowmeter VNT Series

Axial piston pumps type PVC

Axial piston pumps type PVC

Cover Page for Lab Report Group Portion. Pump Performance

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

MECHANICAL BULKMETERS BM Series

Measurement of Low GAS & Liquid Flows

Truck-mounted Mass Flow Metering for LPG Delivery

Liquid ring vacuum pumps in compact design

RMG Meßtechnik GmbH. Publication No E

Two-port valves, male threaded, PN25

ANDERSON GREENWOOD SERIES 9000 POSRV INSTALLATION AND MAINTENANCE INSTRUCTIONS

Torque Tube TB300 Digital Transmitters

American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM

SIHI LPH-X - Liquid Ring Compressors

Turbine Flowmeters for Gas Applications

BGA158 Series CE Approved Class A Shutoff Gas Valve

Dual Solenoid Gas Valve Installation

Model DE-1, VDE-1 and DE-2 Air Release Heads

GM Series Dual-Block Multi-Function Gas Control Valves

Fixed Displacement Pump KFA for commercial vehicles in open circuits

BGA158 Series CE Approved Class B Shutoff Gas Valve

Displacement 12, , Maximum flow rate (at 1450 rpm) bar.

RESOLUTION A.567(14) adopted on 20 November 1985 REGULATION FOR INERT GAS SYSTEMS ON CHEMICAL TANKERS

Pressure Independent Control Series

Turbine Flowmeters for Gas Applications

INSTRUCTION MANUAL. process. Ultrasonic Flowmeter Range

SABERINDO PACIF SABERINDO PACIFIC CIFIC SABERINDO PA. A Tyco International Company

Glass tube flowmeters Series 2000

Orifice Plate Flow Meter

Vortex Flow Meter Wafer or Flange Connection. - Steam - Liquid - Gas

TH-1800-T TRX-700-CNG Converter

Key Features & Advantages of JEHA MK IV (5,000 PSI Hydraulic Test Stands)

BERMAD Waterworks. Level Control Valve with Altitude Pilot. 700 Series. Model X. Features and Benefits. Major Additional Features

Location of CC Number if not located with the identification:

AFC. SDPROC and AFC Analog Mass Flow Controller ANALOG MASS FLOW CONTROLLERS. Principles of Operation. Design Features

Wet pipe low flow foam/water system

PLD 03 T A CASAPPA S.p.A.

Metering Code Gas TSO, measurement by connected party Effective from to the present

VersaFlow Vortex 100 Vortex Flow Meter Technical Datasheet. Specification. The all-in-one solution. Highlights. Industries.

RCD - Ultra-Rugged Differential Pressure Flowmeter

New! ProFlow. Sliding Vane Meters DN (½ - 2 ) _ 142. Product Bulletin

Model Series 62 Constant Differential Relay

THE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv)

SonoMeter 30 Energy Meters

Variable Displacement Double Pump A20VO. Series 1, for open circuits Axial piston - swashplate design, Back to back - design

Inverse Proportional Pressure-Relief Cart., Size 2 4

Target disk flowmeter Series DP. Instructions manual DP65 DP500. R-MI-DP Rev.: 4 English version

APPLICATION. Conveyors Metal working machines Machines for agriculture Road building machines Mining machinery Food industries

Level transmitter LT 100

ABB measurement & analytics data sheet. JAA, JAF and JAG Pneumatic indicating controllers

TECHNICAL MANUAL CALIBRATION INSTRUCTIONS FUEL PRESSURIZING & DUMP VALVE TEST STAND 1TL

Hydraulic pressure balance Model CPB5800

THE BP-690 SERIES. Operating and Service Manual. Series includes all variants of BP-LF/MF-690/691

Liquid ring vacuum pumps in compact design

COMPAFLOW. Compressed Air. Volumetric flow. Gas. Mass flow. Steam. Net volumetric flow. Liquid

Smart Water Application Technologies (SWAT)

776 Cryogenic Safety Valve

CONTROL VALVE TESTING

Glass tube flowmeters Series 2000 Variable area flowmeter for low flows of liquids and gases

Turbine Flowmeters for Gas Applications (Metric)

(AS AT 31 st MARCH, 2002)

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

These Terms and conditions apply to audit trails incorporated in weighing and measuring devices and systems 1.

PRODUCTS CATALOGUE 2017 / Torino - Strada Settimo 388/15 Tel (+39) /43 Fax (+39)

Validation of Custody Transfer Metering Skid at Site After Laboratory Proving

C-Flow Coriolis Mass Flow Meters

Dual displacement motor A10VM Plug-in dual displacement motor A10VE for open and closed circuit applications

Technical Manual. Liquid Level Transmitter CT801-LB/S

Transcription:

Certificate of Approval No 5/6B/211 Issued by the Chief Metrologist under Regulation 60 of the National Measurement Regulations 1999 This is to certify that an approval for use for trade has been granted in respect of the instruments herein described. Macnaught Model WM50 Liquid-measuring System submitted by Macnaught Pty Ltd 41-49 Henderson Street TURELLA NSW 2205 NOTE: This Certificate relates to the suitability of the pattern of the instrument for use for trade only in respect of its metrological characteristics. This Certificate does not constitute or imply any guarantee of compliance by the manufacturer or any other person with any requirements regarding safety. This approval has been granted with reference to document NMI R 117 Measuring Systems for Liquids Other than Water, dated June 2011. This approval becomes subject to review on 3/05/22, and then every 5 years thereafter. DOCUMENT HISTORY Rev Reason/Details Date 0 Pattern & variants 1 to 4 approved interim certificate issued 11/07/07 1 Pattern & variants 1 to 4 approved certificate issued 12/03/08 2 Variant 5 approved interim certificate issued 1/09/08 3 Variant 5 approved certificate issued 19/11/08 4 Variant 6 approved interim certificate issued 12/08/09 5 Variant 6 approved certificate issued 2/09/09 Page 1 of 14

Rev Reason/Details Date 6 Pattern & variants 1 to 6 reviewed & updated certificate 15/05/13 issued 7 Pattern reviewed & updated certificate issued 03/05/17 CONDITIONS OF APPROVAL General Instruments purporting to comply with this approval shall be marked with pattern approval number NMI 5/6B/211 and only by persons authorised by the submittor. It is the submittor s responsibility to ensure that all instruments marked with this approval number are constructed as described in the documentation lodged with the National Measurement Institute (NMI) and with the relevant Certificate of Approval and Technical Schedule. Failure to comply with this Condition may attract penalties under Section 19B of the National Measurement Act and may result in cancellation or withdrawal of the approval, in accordance with document NMI P 106. Auxiliary devices used with this instrument shall comply with the requirements of General Supplementary Certificates No S1/0/A or No S1/0B. Signed by a person authorised by the Chief Metrologist to exercise their powers under Regulation 60 of the National Measurement Regulations 1999. Dr A Rawlinson Page 2 of 14

TECHNICAL SCHEDULE No 5/6B/211 1. Description of Pattern approved on 11/07/07 A bulk flowmetering system incorporating a Macnaught model WM50 (*) 50 mm positive displacement flowmeter (Figure 1 and Table 1) for bulk metering of petroleum products other than LPG. (*) The full model number of the meter is in the form WM50ARP-3 E refer to Table 1. 1.1 Field of Operation The field of operation of the measuring system is determined by the following characteristics: Minimum measured quantity, Vmin 200 L (#1) Maximum flow rate, Qmax 350 L/min Minimum flow rate, Qmin 35 L/min Maximum pressure of the liquid, Pmax 1800 kpa Minimum pressure of the liquid, Pmin 90 kpa (#2) Dynamic viscosity 0.5 to 250 mpa.s (at 20 C) (#3) Liquid temperature range -10 C to 50 C (#4) Ambient temperature range -25 C to 55 C Accuracy class 0.5 (#1) The calculator/indicator indicates the volume at least in 1 L increments. (#2) As specified for the gas elimination device for effective operation. (#3) The flowmeter is adjusted to be correct for the liquid for which it is to be verified/certified as marked on the data plate. (#4) Range may be reduced by the calculator/indicator volume conversion for temperature to 15 C facility. 1.2 Components of the Flowmetering System (i) Tank A supply tank which may incorporate a detector for low liquid-level. The detector is used to prevent further deliveries when the low liquid-level is reached, and prevents air from entering the pipework. (ii) Pump A positive displacement, centrifugal or submersible turbine type pump may be used to provide flow through one or more flowmeters. A submersible turbine type pump may be used either alone or supplying a centrifugal type pump positioned above or below the liquid level of the supply tank. The pump(s) is/are positioned either in a flooded suction configuration, i.e. below the liquid level in the supply tank or in a manner such that the inlet pressure is always greater than the atmospheric pressure and saturated vapour pressure of the liquid. Page 3 of 14

In any case, for all combination of usage, the pump(s) shall be of sufficient capacity to ensure that each flowmeter can operate over its approved flow rate range. (iii) Non-return Valve A non-return valve is fitted upstream of the flowmeter to prevent reverse flow and keep the pipework full of liquid at all times. (iv) Gas Elimination Device (Figure 2a) A Macnaught model MAE21-CA1 gas extractor with an integral filter/strainer (or any other equivalent (*) approved gas elimination device), fitted as close as practical to the flowmeter inlet to prevent vapour entering the flowmeter. For applications where the liquid viscosity exceeds 20 mpa.s at 20 C, for example light oils and hydraulic fluids, the supply tank has low liquid-level detection to automatically stop the pump and a gas elimination device need not be fitted. (*) Equivalent is defined to mean other proprietary equipment of the same or better specifications requiring no changes to the software specified in this approval for satisfactory operation of the complete system. (v) Measurement Transducer The measurement transducer is a Macnaught model WM50ARP-3E positive displacement flowmeter (Figure 2b) incorporating oval gear rotors with two magnets per rotor that pass across a pulser circuit board with dual Hall Effect sensors to produce a dual output signal proportional to the volume throughput. The measuring transducer has the following characteristics: Input supply voltage 4.5 to 24 DC Pulse output Square wave output proportional to supply voltage Nominal k-factor 6.68 pulses/litre per channel Maximum pulse output 39 Hz per channel Cyclic Volume 299.40 ml The flowmeter may be mounted in horizontal or vertical pipelines provided the shaft from the meter to the pulser is in the horizontal plane. (vi) Calibration Adjustment The flowmeter calibration adjustment is achieved using the k-factor and/or meter factor facility provided by the compatible (#) approved controller/indicator. Provision is made in the pipework for measuring the liquid temperature and pressure at the flowmeter during verification/certification of the system. The calibration adjustment is carried out using the liquid which the flowmeter is intended to measure. (vii) Controller/Indicator An Enraf Contrec model Trac-40 controller/indicator or any other compatible (#) approved controller/indicator. The Trac-40 is described in the documentation of approval NMI S367A. For applications where volume at 15 C is required, the approved controller/indicator incorporates volume conversion for temperature facility and is connected to a temperature probe fitted as close as practical to the flowmeter. (#) Compatible is defined to mean that no additions/changes to hardware/software are required for satisfactory operation of the complete system. Page 4 of 14

(viii) Power Supply NMI 5/6B/211 The power supply to the measurement transducer may be provided either by: (a) Connecting to the auxiliary power supply provided by the controller/indicator, such as the Enraf Trac-40, which also incorporates a control relay to stop the pump in the event of a power failure; or (b) (ix) Connecting to a common power source defined by wiring, such that in the event of the power supply failure to the measurement transducer, the delivery pump is simultaneously affected and the flow stops. Transfer Device The transfer device is located downstream of the flowmeter and clearly defines the start and stop of the measured quantity. The transfer device may be in the form of a breakaway coupling, a nozzle or a positive shut-off component, such as a manually or automatically operated flow control valve. Whatever the transfer device used, the pipework upstream of the transfer device shall be maintained full of liquid. The system may have more than one transfer point however the pipework design is such that once the measurement starts the flow continues through the intended transfer point until delivery is finalised; there is no possibility for diverting the measured quantity other than through the intended transfer point. If a nozzle is used, the nozzle has an anti-drain valve installed either in the nozzle or immediately before it, and having a retaining pressure valve of not less than 55 kpa: the nozzle is the transfer device. The pipework between the gas eliminator device and the transfer point shall be kept full of liquid during the measurement and shutdown periods. For systems with hose reel (Figure 1), the volume between the flowmeter and the transfer point shall not exceed the specified minimum measured volume (Vmin) for the flowmeter. 1.3 Verification Provision Provision is made for the application of a verification mark. 1.4 Sealing Provision Refer to approval for the controller/indicator used for sealing requirements. Page 5 of 14

1.5 Descriptive Markings and Notices Each measuring system shall bear the following information, placed together either on the indicating device or on a data plate: Pattern approval mark NMI 5/6B/211 Manufacturer s identification mark or trade mark.. Meter model.. Serial number of the instrument.. Year of manufacture.. Maximum flow rate, Qmax.. L/min Minimum flow rate, Qmin.. L/min Maximum pressure of the liquid, Pmax.. kpa Minimum pressure of the liquid, Pmin.. kpa Type of the liquid for which the system is verified... (#) Environmental class class C (#) This may be located separately, e.g. on a metal tag sealed to the instrument. The minimum measured quantity (Vmin) is clearly visible on the indicating device, e.g. Minimum Delivery 200 L. 2. Description of Variant 1 approved on 11/07/07 The dual Hall Effect sensors replaced by dual Reed switches having a contact rating of 15 VA and a maximum voltage rating of 150 V DC. 3. Description of Variant 2 approved on 11/07/07 The dual Hall Effect sensors replaced by a single Reed switch and a single Hall Effect sensor. 4. Description of Variant 3 approved on 11/07/07 Using certain other Macnaught WM series flowmeters as listed in Table 1 below. Meters may also be known as M series of the same models. The meters are also available in a base mount housing (Figure 3a) and the inlet and outlet ports may be either threaded or flanged (Figures 3b or 3c, respectively). TABLE 1 Flowmeter Model (#) Minimum Flow Rate (Qmin) (L/min) Maximum Flow Rate (Qmax) (L/min) Minimum Delivery (Vmin) (L) WM10 24 (#2) 120 20 WM40 50 (#2) 250 50 WM50 (#3) 70 (#2) 350 200 WM80 (#1) (#3) 140 (#2) 700 200 WM100 (#1) (#3) 240 (#2) 1200 200 Page 6 of 14

(#1) Fitted with model MAE21-CA1 gas extractor or any other compatible approved gas extractor. (#2) The minimum flow rate Qmin reduced to be 1/10 of Qmax when using the linearisation correction facility of the Enraf Trac-40 controller/indicator or any other compatible approved controller/indicator used. (#3) When these model flowmeters are fitted with the rotary encoder pulser of Variant 4, the minimum delivery (Vmin) is 100 litres. (#) The full model number of the meter is in the form WM50ARP-3 E (or M50ARP-3 E ) as set out below in Table 2. WM (or M ) designates meter series TABLE 2 50 designates nominal meter size in mm, e.g. the pattern (model WM50) is nominally 50 mm (2 inch) A R P designates meter body material, namely A = aluminium; or B = bronze; or S = 316 stainless steel. designates rotor material, namely R = resin (WM10, WM40 & WM50 (or M equivalents) only); S = 316 stainless steel (all models); or A = aluminium (WM80 & WM100 (or M equivalents) only) designates output, namely P = integral pulser; or FB = high resolution pulser -3 designates process connections, e.g. 3 = ANSI-150 flanges (can be in the range 1 17 representing the meter port size and Form, e.g. ANSI flanged or BSPP threaded) designates construction type, namely Blank = pipe mount; P = plant (foot mount); or C = compact (foot mount) designates configuration, namely Blank = pipe mount meter; or 0-9 = meter configuration (for foot mount meter only) E designates sensor type, namely Blank = dual Reed PCB; E = dual Hall Effect PCB; or ER = Reed/Hall Effect PCB designates seal (O-ring) material, namely Blank = Nitril (NBR); V = Viton; K = Teflon encapsulated; or J = EDPM Page 7 of 14

5. Description of Variant 4 approved on 11/07/07 With the pulser of the pattern replaced by certain models of the Hontko HPN-6A (*) series of rotary encoder pulsers (Figure 4). (*) The full model number of the pulser has additional alphanumeric suffixes. The pulser characteristics are as follows: Supply voltage: Pulse output: Maximum shaft rotation: Number of outputs: Resolution: (i) (ii) 8 to 26 V DC Square wave output proportional to supply voltage. 2000 rpm Three channels (A, B and Z). WM10, WM40, WM50 flowmeters may be fitted with a pulser that has 100 pulses per shaft revolution for channels A and B; 50 pulses per shaft revolution for channel Z. M80 and M100 are fitted with a pulser that has 1000 pulses per shaft revolution for channels A and B; 500 pulses per shaft revolution for channel Z. When this pulser is fitted to the WM50, WM80 or WM100 flowmeters (or their M series versions), the minimum delivery (Vmin) is 100 litres. 6. Description of Variant 5 approved on 2/09/08 A bulk flowmetering system incorporating a Macnaught model WM7 (or M7) 25 mm positive displacement flowmeter constructed of PPS (Ryton) material and approved for use with AdBlue fluid AUS32 (aqueous urea solution 32.5%). The model WM7 (M7) meter is similar to the pattern (WM50) but has specifications as listed below in Table 3. Flowmeter Model (#) TABLE 3 Minimum Flow Rate (Qmin) (L/min) Maximum Flow Rate (Qmax) (L/min) Minimum Delivery (Vmin) (L) WM7 14 (#1) 70 15 (#) The full model number of the meter is in the form WM7RRP-1 E (or M7RRP-1 E ) as set out in Table 2 for the pattern. (#1) The minimum flow rate Qmin reduced to be 1/10 of Qmax when using the linearisation correction facility of the Enraf Trac-40 controller/indicator or any other compatible approved controller/indicator used. 7. Description of Variant 6 approved on 12/08/09 A bulk flowmetering system incorporating any Macnaught WM series flowmeter, as listed in Table 4 below. Meters may also be known as M series of the same models. Page 8 of 14

7.1 Field of Operation The field of operation for this variant is as described for the pattern except for the following characteristics: Minimum measured quantity, Vmin as listed in Table 4 below Maximum flow rate, Qmax as listed in Table 4 below Minimum flow rate, Qmin as listed in Table 4 below Dynamic viscosity.. (at 20 C) (*) (*) to include products such as: (i) (ii) (iii) AdBlue fluid AUS32 (aqueous urea solution 32.5%), 0.5 to 20 mpa.s; Stock feed additives, 20 to 1000 mpa.s; and Worm castings, vermicast, etc. 0.5 to 20 mpa.s. TABLE 4 Flowmeter Model [#] Minimum Flow Rate (Qmin) (L/min) Maximum Flow Rate (Qmax) (L/min) Minimum Delivery [#1] (Vmin) (L) Material of Construction [#2] Approved Products [#3] M7 14 [#6] 70 15 Pl S & W M10 24 [#6] 120 20 Al & SS A, S & W M40 50 [#6] 250 50 Al & SS A, S & W M50 [#6] 70 [#6] 350 200 Al & SS A, S & W M80 [#4] [#6] 140 [#6] 700 200 Al & SS A, S & W M100 [#4] [#4] 240 [#6] 1200 200 Al & SS A, S & W [#] The full model number of the meter is in the form WM50ARP-3 E (or M50ARP-3 E ) as set out in Table 2 for the pattern. [#1] Minimum measured quantity, Vmin, also known as Minimum Delivery. [#2] Al = aluminium, Pl = plastic, SS = 316 stainless steel. [#3] A = AdBlue, S = stock feed additives, W = worm castings. [#4] Fitted with a model MAE21-CA1 gas extractor or any other compatible approved gas extractor. [#5] The minimum flow rate Qmin reduced to be 1/10 of Qmax when using the linearisation correction facility of the Enraf Trac-40 controller/indicator or any other compatible approved controller/indicator used. [#6] When these model flowmeters are fitted with the rotary encoder pulser of Variant 4, the minimum delivery (Vmin) is 100 litres. Page 9 of 14

TEST PROCEDURE No 5/6B/211 Instruments shall be tested in accordance with any relevant tests specified in the National Instrument Test Procedures. Tests should be conducted in conjunction with any tests specified in the approval documentation for any controller/indicator and/or any conversion device, etc. used. The instrument shall not be adjusted to anything other than as close as practical to zero error, even when these values are within the maximum permissible errors. Maximum Permissible Errors The maximum permissible errors are specified in Schedule 1 of the National Trade Measurement Regulations 2009. Power Failure Test This test need only be carried out for new installations or when the power supply wiring to the measurement transducer or controller/indicator has been altered. Interrupt the power supply to the measurement transducer and check that the delivered volume and the volume displayed by the controller/indicator does not exceed a volume equal to the sum of 0.5% of the delivered volume plus 5% of Vmin specified for the flowmeter. Page 10 of 14

FIGURE 5/6B/211 1 NMI 5/6B/211 Macnaught Model WM50 Flowmetering System (Including Showing a Typical Delivery System With Hose Reel) Page 11 of 14

FIGURE 5/6B/211 2 NMI 5/6B/211 (a) Macnaught Model MAE21-CA1 Gas Extractor With Integral Filter/Strainer (b) Macnaught Model WM50ARP-3E Flowmeter With Integral Pulser Page 12 of 14

FIGURE 5/6B/211 3 NMI 5/6B/211 (a) WM (or M) Series Flowmeter With Base (Foot) Mount Body (b) Model WM10 (or M10) With Threaded Ports (c) Model WM100 (or M100) With Flange Ports Page 13 of 14

FIGURE 5/6B/211 4 NMI 5/6B/211 Macnaught Model M50 Flowmeter with a Hontko HPN-6A Series Rotary Encoder Pulser ~ End of Document ~ Page 14 of 14