In-line Air Filter. 100 kpa to 1.0 MPa. New RoHS. Series ZFC. Operating pressure range

Similar documents
Relays/Valves. Lock-Up Valve. Series IL201/211/220 EMC.IL A-UK

Vacuum Saving Valve Series ZP2V How to Order ZP2V A5 03 Connection thread symbol for the pad Male thread connection Symbol Thread Applicable fixed ori

No.IL02-OM00011-A PRODUCT NAME LOCK UP VALVE. MODEL/ Series IL201 IL211

Air operated valve. VGA342R Series

30% (SMC comparison) Silencer. New. New. The M5 silencer is now added! The resin silencer is now a more compact size! Series AN.

14.5 m kg. Main Line Filter. 5 kpa or less. New. AFF Series. 160 mm. 170 mm 20 %

Doc. No.SYJ300-OMO0002-A. Air Operated Valve PRODUCT NAME. SYJA300 / SYJ3000 Series MODEL/ Series

COMMON PRECAUTIONS Data Sheet - Be Sure To Read Before Handling Page 1 of 6

Port size. Model Screw-in ZFA10 1/8 ZFA20 1/4 ZFB10 ZFB20 ZFB30 ZFB40 ZFC5 ZFC7

Prevents condensation

Industrial Filter. FGD series

IR1200-A IR2200-A IR3200-A

Series ZFC. Air Suction Filter In-line Type with One-touch Fittings

Series ITVH CAT.EUS60-23A-UK

PRODUCT NAME. Main Line Filter. MODEL / Series / Product Number

90 % [l/min (ANR)] Compared with the current IR1000/2000/3000. twice. [l/min (ANR)] Compared with the current IR1000/ %

Series AS-FPQ/AS-FPG. Speed Controller with One-touch Fitting for Clean Room. Speed controllers for clean room use

5 Port Air Operated Valve

Pressure Relief 3 Port Valve New. Sonic Conductance 45% With the indicator window Step1. With locking holes

Related Products: Auto Drain Valve. Model/Specifications. Model

Series IR1000/2000/3000

Membrane Air Dryer. IDG1-C06 Series IDG1-C06-P Series

Lightweight and Compact Type Floating Joint

Series ZFC. Air Suction Filter. In-line Type with One-touch Fittings

Filter-Regulator-Lubricator

Series IRV1000/2000/3000

Series SFD. Clean Air Filter. Variations. Made to Order. Type. Cartridge (replaceable element) Disposable (non-replaceable element) Up to 100

Booster Regulator/Air Tank Increase factory air pressure by up to 4 times! Air-only operation requires no power supply, reduces heat generation, and

Pressure Sensor/ PSE57 /PSE300AC Series. 3-Screen Display Sensor Monitor 500 V AC. Remote Type. Change the settings while checking the measured value.

reduces flow setting time and setting errors!

Series AMJ. Drain Separator for Vacuum

SeriesTRBU. Flame Resistant (Equivalent to UL-94 Standard V-0) FR Double Layer Polyurethane Tubing

How to Order. Body size. Pressure: 2 MPa. Pressure increase ratio 0 Twice. Symbol. Thread type. Body size

(100: 1) Expanded flow range! Compact, Space saving. 2-Colour Display Digital Flow Switch Applicable fluid. Series PFMB. Air, N2

Pilot Check Valve: Metal Body Type

SAFETY IN FOCUS BASIC GUIDE TO SAFETY PNEUMATIC CIRCUITS FOR ISO YOUR AUTOMATION PARTNER

Moisture Control Tube

Doc. No.VFR3000-OMH0005-B. 5 Port Air Operated Valve PRODUCT NAME. VFRA3000, 4000 Series MODEL/ Series

kpa or less 5.0. Compressed Air Preparation Filter. AFF/AM/AMD Series CAT.ES30-17B. 1 μm (Current model: 3 μm) 20% 60% 52% 160 mm.

Digital Flow Switch. New. New. Expanded flow range! Compact, Space saving Compared with the current PF2A, 2-Colour Display. Series PFMB.

Vacuum Pad with Ejector. Series ZHP

Machinery Directive (MD) 2006/42/EC. SMC meeting tomorrow s machine safety standards today

IR1000-A IR1010-A IR1020-A

5.0 MPa Maximum Supply Pressure. New. Stepless control of air pressure proportional to an electrical signal. Series ITVX CAT.

Pressure Sensor PSE53#

Change Valve. Push-In Fitting Type Three-way Changeover Valve. Changeover Air Direction by 90. Lightweight and Compact Design.

Cautions : 1. Be careful when you release the Stop Fitting with some internal pressure

F.R.L. Units Precautions 1 Be sure to read this before handling.

(1) Type (2) Thread size (T) (3) Wrench size specification : inch spec. (NPT, UNF) : mm spec. (M, R)

5 Port Solenoid Valve

Cautions : 1. Clogging of the element raises resistance to exhaust, thus lowering the

Hand Valve Series. Push-In Fitting Type Shut-off Valve (Residual Pressure Release Valve) Control Open/Close for Air Supply.

Miniature Tubing & Miniature Fittings

Coiling Tube with Twist-Proof Fitting

Recommended applicable tubing. Specifications. Operating vacuum pressure. 20 C to 80 C Threads. Principal parts material

(1) Name of tube (2) Tube dia. (O.D./I.D.) (3) Tube length. (4) Tube color. Model UD0425. UD1290 O.D. I.D. (mm) UD1075 UD0860 UD

Operation Manual Air Saver Unit ASV5000 Series

435 psi (3.0 MPa) Maximum Supply Pressure High Pressure Electro-Pneumatic Regulator. Maximum supply pressure. Set pressure range.

(1) Type. (2) Tube dia. (ød) : ø8mm (ø5/16in.) (3) Thread size (T) (4) Specification. Fluid medium. Air, water * 1, * 2, * 3 Max. operating pressure

Filter-Regulator-Lubricator

IRV Series. Vacuum Regulator. New RoHS. New and Improved. Series IRV10/20

8 to 2000 ml/min PB1013A and PB1313A are available up to 1000 ml/min. 52 mm. Car washing machine Water/ detergents supply. Body wetted parts PB1011A

Push-In Fitting Type Silencer

Cautions : 1. The gauge orientation on the GPU and GPM types can be changed by using

PVC Quick Drain Valve

Insert Ring. Protection Ring from Tube Deformation. Protect tubes from deformation. Ultra soft tube is connectable to Fitting.

Push-In Fitting Type Pressure Gauge

Pressure Sensor PSE54#

F.R.L. Units Precautions 1 Be sure to read this before handling products.

(1) Type (2) Cylinder dia. (3) Gripper action : Single-acting closing gripper (normally open) (4) Holder type

Parallel Seal Type Slit Valve

Air preparation filter

Tube Cutter with Measuring tape built-in

Low torque Metal seal type Rotary joint

Series 10-IRV10/20. Vacuum Regulator C08 IRV C08 IRV 20 A. How to Order. Standard connections. Single sided connections. Accessory w Nil G ZN ZP ZA ZB

Process Pump PB1000A

Push-In Fitting Type with Stop Valve

Precision Regulator IR3120

The plastic bowl guard does not corrode. The draining method is selectable between the push type and the auto drain type.

(2) Effective sectional area (no code for mini type) (3) Intake-side shape (no code for mini type) : Quick-fitting joint type : Taper pipe thread type

New Product. Air Consumption 70% Down. Precision Regulator Air Saving Type. RPE Series PRECISION REGULATOR RPE SERIES CC-1072A

Suitable for Semi-Conductor, Measuring Instrument, Printing and Medical Industries

High Vacuum L Type Valve PRODUCT NAME. XLF Series MODEL/ Series

Low Friction Cylinders

Model PCøD-TSUS PC4-M6SUS PC4-01SUS PC4-02SUS PC6-M5SUS PC6-M6SUS PC6-01SUS PC6-02SUS PC16-03SUS

Pressure Gauge Series

Regulator for 2 MPa ARX 20. How to Order. Bracket. Pressure gauge. Port size 1/8 1/4. Panel nut

Tube for Clean Environment Polyurethane Tube Clean-Room Package

Static dissipative Resin (Surface Resistivity : 10 4 ~10 7 Ω).

VACUUM REGULATORS CONTENTS

Compressed Air Cleaning Filter Series

(1) Union Filter for positive and negative pressure (2) Filter size. (3) Tube dia. (4) Holder option : without Holder : with Holder

Vacuum Regulator. IRV10/20 Series. Weight reduced by. RoHS ARJ ARX AMR ARM ARP IR -A IR IRV VEX SRH SRP SRF ITV

Coiling Tube Series. Coiling Tube for General Pneumatic Piping. Coiling Tube for General Pneumatic Piping. Suitable for Air Gun or Air Driver.

Anti-spatter Tube. Spatter-Proof Tube for Pneumatic Piping. Polyamide type Tube Coated with Flame-Retardant Resin(Equivalent to V-0 )

Clean Regulator/Fluororesin Type

1.0. ISE70/71 Series CAT.ES A. MPa/1.6 MPa. 3-Screen Display High-Precision Digital Pressure Switch. Angled display.

Ball Valve Series. Push-In Fitting Type Shut-off Valve. Control Open/Close Air Supply. Ensure Effective Area for Variety of Tube Dia.

Model SPCøD-T SPC4-M5 SPC4-M50 * 1 SPC4-M6 SPC4-02 SPC6-M5 SPC6-M6 SPC6-01 SPC6-02 SPC16-03

Wafer Check Valve. Contents. User s Manual. (1) Be sure to read the following description of our product warranty 1

Transcription:

In-line Air Filter Operating pressure range 0 kpa to 1.0 MPa Both positive pressure and vacuum pressure can be used with one unit! Positive pressure 1.0 MPa e.g.) Protection of solenoid valves Positive pressure 0 to 1 MPa IN OUT Vacuum pressure 0 kpa Filtration μm Vacuum pressure 0 to 0 kpa Workpiece IN Pad Protection of equipment under dust environment New RoHS OUT Series Variations ZFC Series ø4 ø/32" Maximum flow rate under positive pressure [] Metric size Inch size 0 0 0 4 ø1/4" 0 ZFC7 ø1/4" 1 ø/16" 20 ø3/8" 0 ø12 30 Flow rate (positive pressure) conditions: Supply pressure 0.1 MPa, Differential pressure kpa Metric size: sizes Inch size: 4 sizes Light grey Orange Series ZFC CAT.EUS0-3A-UK

Series ZFC With lock mechanism During positive pressure, prevents components from being scattered when they are loosened. 2 types of transparent case materials are available. Polycarbonate (Standard) Possible to degrease with alcohol. 2 element colours are available. No adhesion of foreign matter Nylon (Made to Order) Resistant to coolant oil Blue element (Made to Order) White element (Standard) With One-touch fitting Metric size: ø4 to ø12 Inch size: ø/32" to ø3/8" Adhesion of foreign matter 2 levels of filtration rating are available. μm μm/made to Order Easy to visually check white foreign matter Available with different bores on IN and OUT sides IN side < OUT side IN port size OUT port size ø4 IN side > OUT side IN port size OUT port size ø12 IN side IN side Made to Order OUT side OUT side Application examples Improvement of air quality for air blow Flexible mounting orientation Allow a sufficient margin of tube length when piping, in order to prevent twisting, tensile, moment loads, vibration or impact being applied to the tubes and filter body. Features 1

Filter Variations Flow rate under vacuum condition Flow rate under positive pressure In-line Air Filter For positive pressure Series AF to 0 ZFC777 AF AF to 30 to 30 Spacesaving Easy to install to the line Flexible mounting orientation to to 0 For vacuum pressure to 0 ZFC4 ZFB to 0 ZFA Flow rate (positive pressure) conditions: Supply pressure 0.1 MPa, Differential pressure kpa Features 2

In-line Air Filter Series ZFC RoHS How to Order ZFC 4 B 7 3 4 6 7 B D E F Body size L/min 0 L/min Body size Filtration area 70 mm 2 1260 mm 2 Metric size ø4 ø12 ø/32" ø1/4" ø/16" ø3/8" ZFC ZFC7 Inch size X01 X02 X03 X04 X0 X06 Option None B With bracket Made to Order Refer to page for details. Specifications Different diameters (IN side < OUT side) Different diameters (IN side > OUT side) Blue element Filtration: μm FKM/Oil free (Seal) Nylon Specifications Max. Operating Pressure and Operating Temperature Model Port size () Metric size Inch size Fluid Operating pressure Flow rate (Positive pressure) [L/min] Note) Flow rate (Vacuum pressure) [L/min] Proof pressure [MPa] Operating and ambient temperature range [ C] F]iltration [μm] Element replacement differential pressure [MPa] Filtration area [mm 2] Applicable tubing material Weight [g] Internal capacity [cm3] Total length [mm] Total width [mm] Bracket total length [mm] Case material ø4 ø/32" 4 ZFC 70. 4. 3.9 19.0 23.0 ø1/4" 0 ø1/4" ZFC7 Air, Nitrogen 0 kpa to 1.0 MPa 1 ø/16" 20 70 1. 0 to 60 (Filtration efficiency 9%) 0.1 (Vacuum pressure kpa) 1260 Nylon, Soft nylon, Polyurethane.0 6.0 68.4 23.6 27.3 Polycarbonate ø3/8" 0 80 2.0 7.0 79.7 ø12 30 0 Note) Flow rate (positive pressure) conditions: Supply pressure 0.1 MPa, Differential pressure kpa Max. operating pressure [MPa] 1.0 0.8 0.6 0.4 0.2 0.0 0 40 0 60 Operating temperature [ C] 1

In-line Air Filter Series ZFC Flow Characteristics ZFC3 ø4 ZFC4 0.1 MPa 0.3 MPa 0.1 MPa 0.3 MPa Differential pressure [kpa] 0.7 MPa 0. MPa Differential pressure [kpa] 0.7 MPa 0. MPa 0 0 40 60 80 0 Flow rate [] 0 0 0 0 10 0 Flow rate [] ZFC74 ZFC7 0.1 MPa 0.3 MPa 0. MPa 0.1 MPa 0.3 MPa Differential pressure [kpa] 0.7 MPa Differential pressure [kpa] 0.7 MPa 0. MPa 0 0 0 0 10 0 20 Flow rate [] 0 0 0 0 0 400 00 Flow rate [] ZFC76 ZFC77 ø12 0.1 MPa 0.3 MPa 0.1 MPa 0.3 MPa Differential pressure [kpa] 0.7 MPa 0. MPa Differential pressure [kpa] 0.7 MPa 0. MPa 0 0 0 400 600 Flow rate [] 0 0 0 400 600 Flow rate [] 2

Series ZFC Construction Component Parts No. Description Material Quantity 1 2 3 4 Case Cover Element Seal Bracket PC Resin PBT Sintered resin HNBR Resin PBT 1 2 1 2 1 One-touch fittings w OUT Replacement Element Part No. Part no. Applicable filter model Element size Set description ZFC-EL-3 ZFC-EL-4 ZFC ZFC7 ø12 x x L ø16 x ø12 x L2 Spare element: pcs. Spare element: pcs. e q r t IN Element Replacement Procedure 1. Stop operation and reduce the filter s internal pressure to atmosphere. 2. Slide the lock mechanism in the direction of the arrow to release the lock. 3. Rotate the cover counterclockwise at least 90 degrees. 4. Pull the cover out of the case to remove the element. Remove dust and other debris remaining inside the case by blowing it out with air, etc. (Also, confirm that the O-ring is not damaged.). Install a new element on cover and insert it into the case. 6. Align the raised part of the cover with the model no. display of the body, and push the cover to the end of the body and rotate it clockwise until it stops. 7. Set the lock mechanism and check that the cover is locked completely. Unlocked state Locked state Procedure 2 Rotating Procedure 3 Product no. display Procedure 7 Procedure 6 Case Element Cover Procedure 4 Protrusion on the cover Procedure 3

In-line Air Filter Series ZFC Dimensions ZFC (ø4, ) 4. 6.4 1.7 13. 24.7 ø19 33.4 (ø4, ) IN 18 23 3.9 ZFC7 (,, ø1/4", ø/16") 4. ø23.6 8.7.7 19.2 28. 24 34 68.4 8.7 26.7 19.2 33.8 24 39.8 (,, ø1/4", ø/16") IN 27.3 ZFC7 (, ø12, ø3/8") 4. ø23.6 39.8 (, ø12, ø3/8") IN 27.3 34 79.7 4

Series ZFC Made to Order Please contact SMC for detailed specifications, dimensions and delivery. 1 Different diameters (IN side < OUT side) IN side applicable tubing O.D. (Metric size): ø4 OUT side applicable tubing O.D. (Metric size): ZFC 3 X01 -X01 3 Blue element Easy to recognize white foreign matter on the element by colouring the element. Standard product X03 -X03 IN side < OUT side Blue element 3 IN port ø4 OUT port IN side Option None B With bracket OUT side 4 Filtration: μm Standard product X04 -X04 Filtration: μm 2 Different diameters (IN side > OUT side) IN side applicable tubing O.D. (Metric size): to ø12 OUT side applicable tubing O.D. (Metric size): to ZFC7 6 7 IN side ø12 OUT side X02 -X02 IN side > OUT side Option None B With bracket 6 Seal material: FKM Oil free: Seal Standard product X0 Case material: Nylon Standard product X06 Case material: Nylon -X0 -X06 IN side OUT side

Series ZFC Specific Product Precautions 1 Be sure to read before handling. Refer to back cover for Safety Instructions, Handling Precautions for SMC Products (M-E03-3) and Operation Manual for Vacuum Equipment Precautions. Please download it via our website, http://www.smc.eu Caution Mounting 1. Operation manual Install the products and operate them only after reading the operation manual carefully and understanding its contents. Also, keep the manual where it can be referred to as necessary. 2. Maintenance space Allow sufficient space for maintenance and inspection. 3. Observe the tightening torque for screws. Tighten the screws to the recommended torque for mounting the product. 4. Connect tubing to the IN and OUT One-touch fittings in accordance with the precautions for Onetouch fittings. 1. Connect the piping after checking the arrow indication showing the flow direction on the body. If the piping is connected the other way around, it is not possible to seal the element. 2. Positive and negative pressures cannot be used together in the same circuit. 3. Allow a sufficient margin of tube length when piping, in order to prevent twisting, tensile, moment loads, vibration or impact being applied to the tubes and filter body. Maintenance 1. Perform maintenance inspection according to the procedures indicated in the operation manual. If handled improperly, malfunction and damage of machinery or equipment may occur. 2. Maintenance work If handled improperly, compressed air can be dangerous. Assembly, handling, repair and element replacement of pneumatic systems should be performed by a knowledgeable and experienced person. 3. Drain flushing Remove drainage regularly from the air filters, etc. 4. Removal of equipment, and supply/exhaust of compressed air When components are removed, first confirm that measures are in place to prevent workpieces from dropping, run-away equipment, etc. Then, cut off the supply pressure and electric power, and exhaust all compressed air from the system using the residual pressure release function. When machinery is restarted after remounting or replacement, confirm that the equipment is operating normally. Caution Maintenance. The performance of an ejector will deteriorate due to clogged suction filters and silencers. High flow filters should be used, especially in dusty locations. Vacuum release valve Speed controller for release flow adjustment If a filter is required on the release pressure side, a different filter should be prepared. Not possible to use vacuum pressure and positive pressure together in the same line. 6. When the element becomes clogged, stop operation and adjust the internal pressure of the filter to atmospheric pressure before replacing the element. 1. Element should be replaced in either of the two cases below. 1) When pressure drop reaches 0.1 MPa in a positive pressure or kpa in a vacuum pressure. 2) When the set values (flow rate, vacuum reaching time) change. 2. During disassembly and assembly, confirm that there are no scratches or damage, etc, on the O-ring. 3. Before using, confirm there is no leakage after replacing elements. Pad Vacuum pump Vacuum switch valve Air suction filter Vacuum pressure switch 6

Series ZFC Specific Product Precautions 2 Be sure to read before handling. Refer to back cover for Safety Instructions, Handling Precautions for SMC Products (M-E03-3) and Operation Manual for Vacuum Equipment Precautions. Please download it via our website, http://www.smc.eu Recommended Piping Conditions 1. When connecting piping to the One-touch fitting, use pipe length with sufficient margin, in accordance with the piping conditions shown in Figure 1. Also, when using a tying band, etc., to bind the piping together, make sure that external force does not come to bear on the fitting. (see Figure 2) Tubing size ø4, /32" ø1/4", /16" ø3/8" ø12 Straight line Mounting pitch A Figure 1 Recommended piping Mounting pitch A Nylon tube Soft nylon tube Polyurethane tube 6 or more or more 26 or more 84 or more 39 or more 39 or more 89 or more 6 or more 7 or more 112 or more 8 or more 2 or more 140 or more 70 or more 69 or more 134 or more 76 or more 69 or more 168 or more 82 or more 88 or more Recommended No good Unit: [mm] Straight-line pipe length or more or more 32 or more 40 or more 0 or more 48 or more 60 or more Figure 2 When using a tying band to bind the piping together Handling of One-touch Fittings Caution 1. Tubing attachment/detachment for One-touch fittings 1) Installing of tubing (1) Use tubing with no flaws on its periphery and cut it off at a right angle. When cutting the tubing, use a tube cutter, TK-1, 2 or 3. Do not use pinchers, nippers or scissors, etc. If cutting is done with tools other than tube cutters, the tubing may be cut diagonally or become flattened, etc. This can make a secure installation impossible, and cause problems such as the tubing pulling out after installation or air leakage. Allow some extra length in the tubing. (2) The outside diameter of the polyurethane tubing swells when internal pressure is applied to it. Therefore, it may not be possible that the tubing can be re-inserted into the One-touch fitting. Confirm the tubing outside diameter, and when the accuracy of the outside diameter is +0.1 or larger, re-insert the tubing into the One-touch fitting without cutting it. When the tubing is re-inserted into the One-touch fitting, confirm that the tubing goes through the release button smoothly. (3) Grasp the tubing and push it in slowly, inserting it securely all the way into the fitting. (4) After inserting the tubing, pull on it lightly to confirm that it will not come out. If it is not installed securely all the way into the fitting, this can cause problems such as air leakage or the tubing pulling out. 2) Removal of tubing (1) Push in the release button sufficiently. When doing this, push the collar evenly. (2) Pull out the tubing while holding down the release button so that it does not come out. If the release button is not pressed down sufficiently, there will be increased bite on the tubing and it will become more difficult to pull it out. (3) When the removed tubing is to be used again, cut off the portion which has been chewed before reusing it. If the chewed portion of the tubing is used as it is, this can cause trouble such as air leakage or difficulty in removing the tubing. 2. Do not install the SMC s KQ One-touch fitting series with a metal rod into the ZFC series fittings. The metal rod will not be held and the fitting will shoot out. 7

Series ZFC Specific Product Precautions 3 Be sure to read before handling. Refer to back cover for Safety Instructions, Handling Precautions for SMC Products (M-E03-3) and Operation Manual for Vacuum Equipment Precautions. Please download it via our website, http://www.smc.eu Caution Other Tube Brands 1. When tubing of brands other than SMC s are used, verify that the tubing O.D. satisfies the following accuracy; 1) Nylon tubing : Within ±0.1 mm 2) Soft nylon tubing : Within ±0.1 mm 3) Polyurethane tubing : Within +0.1 mm, Within 0.2 mm Do not use tubing which does not meet these outside diameter tolerances. It may not be possible to connect them, or they may cause other trouble, such as air leakage or the tube pulling out after connection. 2. Connecting products with metal rods After connecting the products with metal rods (Series KC, etc.) to the One-touch fittings, do not use tubes, resin plugs or reducers, etc. These may come off the fittings. Design 1. Confirm the specifications. Products represented in this catalogue are designed only for use in compressed air systems (including vacuum). Do not operate at pressures or temperatures, etc., beyond the range of specifications, as this can cause damage or malfunction. (Refer to the specifications.) Please contact SMC when using a fluid other than compressed air (including vacuum). We do not guarantee against any damage if the product is used outside of the specification range. 2. Modification prohibited Do not make any modifications, including additional machining. It may cause human injury and/or an accident and will void the warranty. Air Supply 1. Type of fluids Please consult with SMC when using the product in applications other than compressed air. 2. When there is a large amount of drainage. Compressed air containing a large amount of drainage can cause malfunction of pneumatic equipment. An air dryer or water droplet separator should be installed upstream from filters. 3. Drain flushing If condensate in the drain bowl is not emptied on a regular basis, the condensate will overflow and allow it to enter the compressed air lines. This will cause a malfunction of pneumatic equipment. If the drain bowl is difficult to check and remove, installation of a drain bowl with an auto drain option is recommended. Refer to SMC Air Preparation System for further details on compressed air quality. 4. Use clean air. Do not use compressed air that contains chemicals, synthetic oils including organic solvents, salt or corrosive gases, etc., as it can cause damage or malfunction. Operating Environment 1. Do not use in an atmosphere having corrosive gases, chemicals, sea water, water, water steam, or where there is direct contact with any of these. 2. Do not use in a place subject to heavy vibration and/or shock. 3. Do not use in an environment where flammable gas or explosive gas exists. Usage may cause a fire or explosion. The products do not have an explosion proof construction. 4. The valve should not be exposed to prolonged sunlight. Use a protective cover.. Remove any sources of excessive heat. 6. In locations where there is contact with spatter from water, oil, solder, etc., take suitable protective measures. 8

Safety Instructions Caution: : Danger : Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury. These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of Caution, or Danger. They are all important notes for safety and must be followed in addition to International Standards (ISO/IEC) 1), and other safety regulations. 1) ISO 4414: Pneumatic fluid power General rules relating to systems. ISO 4413: Hydraulic fluid power General rules relating to systems. IEC 604-1: Safety of machinery Electrical equipment of machines. (Part 1: General requirements) ISO 218-1: Manipulating industrial robots - Safety. etc. 1. The compatibility of the product is the responsibility of the person who designs the equipment or decides its specifications. Since the product specified here is used under various operating conditions, its compatibility with specific equipment must be decided by the person who designs the equipment or decides its specifications based on necessary analysis and test results. The expected performance and safety assurance of the equipment will be the responsibility of the person who has determined its compatibility with the product. This person should also continuously review all specifications of the product referring to its latest catalogue information, with a view to giving due consideration to any possibility of equipment failure when configuring the equipment. 2. Only personnel with appropriate training should operate machinery and equipment. The product specified here may become unsafe if handled incorrectly. The assembly, operation and maintenance of machines or equipment including our products must be performed by an operator who is appropriately trained and experienced. 3. Do. not service or attempt to remove product and machinery/equipment until safety is confirmed. 1. The inspection and maintenance of machinery/equipment should only be performed after measures to prevent falling or runaway of the driven objects have been confirmed. 2. When the product is to be removed, confirm that the safety measures as mentioned above are implemented and the power from any appropriate source is cut, and read and understand the specific product precautions of all relevant products carefully. 3. Before machinery/equipment is restarted, take measures to prevent unexpected operation and malfunction. 4. Contact SMC beforehand and take special consideration of safety measures if the product is to be used in any of the following conditions. 1. Conditions and environments outside of the given specifications, or use outdoors or in a place exposed to direct sunlight. 2. Installation on equipment in conjunction with atomic energy, railways, air navigation, space, shipping, vehicles, military, medical treatment, combustion and recreation, or equipment in contact with food and beverages, emergency stop circuits, clutch and brake circuits in press applications, safety equipment or other applications unsuitable for the standard specifications described in the product catalogue. 3. An application which could have negative effects on people, property, or animals requiring special safety analysis. 4. Use in an interlock circuit, which requires the provision of double interlock for possible failure by using a mechanical protective function, and periodical checks to confirm proper operation. Caution 1. The product is provided for use in manufacturing industries. The product herein described is basically provided for peaceful use in manufacturing industries. If considering using the product in other industries, consult SMC beforehand and exchange specifications or a contract if necessary. If anything is unclear, contact your nearest sales branch. Limited warranty and Disclaimer/ Compliance Requirements The product used is subject to the following Limited warranty and Disclaimer and Compliance Requirements. Read and accept them before using the product. Limited warranty and Disclaimer 1. The warranty period of the product is 1 year in service or 1. years after the product is delivered, wichever is first. 2) Also, the product may have specified durability, running distance or replacement parts. Please consult your nearest sales branch. 2. For any failure or damage reported within the warranty period which is clearly our responsibility, a replacement product or necessary parts will be provided. This limited warranty applies only to our product independently, and not to any other damage incurred due to the failure of the product. 3. Prior to using SMC products, please read and understand the warranty terms and disclaimers noted in the specified catalogue for the particular products. 2) Vacuum pads are excluded from this 1 year warranty. A vacuum pad is a consumable part, so it is warranted for a year after it is delivered. Also, even within the warranty period, the wear of a product due to the use of the vacuum pad or failure due to the deterioration of rubber material are not covered by the limited warranty. Compliance Requirements 1. The use of SMC products with production equipment for the manufacture of weapons of mass destruction (WMD) or any other weapon is strictly prohibited. 2. The exports of SMC products or technology from one country to another are governed by the relevant security laws and regulations of the countries involved in the transaction. Prior to the shipment of a SMC product to another country, assure that all local rules governing that export are known and followed. Safety Instructions Be sure to read Handling Precautions for SMC Products (M-E03-3) before using. SMC Corporation (Europe) Austria +43 (0)2262622800 www.smc.at office@smc.at Belgium +32 (0)331464 www.smcpneumatics.be info@smcpneumatics.be Bulgaria +39 (0)2807670 www.smc.bg office@smc.bg Croatia +38 (0)13707288 www.smc.hr office@smc.hr Czech Republic +4 41424611 www.smc.cz office@smc.cz Denmark +4 7022900 www.smcdk.com smc@smcdk.com Estonia +372 6370 www.smcpneumatics.ee smc@smcpneumatics.ee Finland +38 71313 www.smc.fi smcfi@smc.fi France +33 (0)1647600 www.smc-france.fr promotion@smc-france.fr Germany +49 (0)6340 www.smc.de info@smc.de Greece + 2 271726 www.smchellas.gr sales@smchellas.gr Hungary +36 2311390 www.smc.hu office@smc.hu Ireland +33 (0)14039000 www.smcpneumatics.ie sales@smcpneumatics.ie Italy +39 0292711 www.smcitalia.it mailbox@smcitalia.it Latvia +371 67817700 www.smclv.lv info@smclv.lv Lithuania +370 28118 www.smclt.lt info@smclt.lt Netherlands +31 (0)318888 www.smcpneumatics.nl info@smcpneumatics.nl Norway +47 671290 www.smc-norge.no post@smc-norge.no Poland +48 (0)222119616 www.smc.pl office@smc.pl Portugal +31 22616670 www.smc.eu postpt@smc.smces.es Romania +40 213111 www.smcromania.ro smcromania@smcromania.ro Russia +7 81271844 www.smc-pneumatik.ru info@smc-pneumatik.ru Slovakia +421 (0)413213212 www.smc.sk office@smc.sk Slovenia +386 (0)7388412 www.smc.si office@smc.si Spain +34 9021840 www.smc.eu post@smc.smces.es Sweden +46 (0)8603 www.smc.nu post@smc.nu Switzerland +41 (0)23963131 www.smc.ch info@smc.ch Turkey +90 212 489 0 440 www.smcpnomatik.com.tr info@smcpnomatik.com.tr UK +44 (0)84 121 122 www.smcpneumatics.co.uk sales@smcpneumatics.co.uk SMC CORPORATION Akihabara UDX 1F, 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 1-0021, JAPAN Phone: 03-7-8249 FAX: 03-298-362 1st printing RV printing RV 00 Printed in Spain Specifications are subject to change without prior notice and any obligation on the part of the manufacturer.