Versatility. Accuracy. Compact. Versa. Automated Headspace Vial Sampler

Similar documents
Environmental Petrochemical, Pharmaceutical, Foods & Flavors, Chemicals, Personal Care, Forensics,...and more!

General Specifications: Forensic. Petrochemical Environmental. Lab Quality Analyses in the Field, It Goes with you Anywhere!

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

Automated Determination of Dissolved Gases in Water Anne Jurek. Abstract: Discussion:

The HumiPyc - Model 1 - Gas Pycnometer; Density, Moisture, Permeation Analyzer; RH sensor Calibrator

Headspace Troubleshooting Made Easy. Presented today by: Susan Scheib Sr. Technical Support Specialist Joe Barta FSE Chicago & Escalation Engineer

Sorbent Pen Heavy & Labile SVOC s Taints, Off-Flavors, Odors

HumiSys HF High Flow RH Generator

The HumiPyc ( Model 2) - Gas Pycnometer; Density, Moisture, Permeation Analyzer; Filter Integrity Tester; RH sensor Calibrator

Automated Determination of Dissolved Gases in Water Anne Jurek

UNITY 2 TM. Air Server Series 2 Operators Manual. Version 1.0. February 2008

Ghost Peaks: How to Fix a Haunting Problem. Jacob A. Rebholz Teledyne Tekmar VOC Product Line Manager

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs.

780S Ultra High Purity Series

Optimizing Vial Pressurization Parameters for the Analysis of <USP 467> Residual Solvents Using the 7697A Headspace Sampler

Automated Determination of Dissolved Gases in Water By Headspace Calibration of Mixed Gases Anne Jurek

Agilent 7697A Headspace Sampler

Major Design Features

A SCENT OF FUTURE. Master DHS. Dynamic Head Space Sampler. Operating Manual

Rapid and Reliable Detection of Dissolved Gases in Water

Ruskinn Hypoxia and Anoxia Workstations. innovation in incubation

THE PMI AUTOMATED GAS/HELIUM PYCNOMETER PYC-G100A

SHORT FORM CATALOGUE

BUBBLER CONTROL SYSTEM

BUBBLER CONTROL SYSTEM

FAST EVAPORATION AT NORMAL PRESSURE

The Tekran Series 2600-IVS Difference!

The instrument will process the samples one by one till all the samples have been cleaned up.

Series Ruska Digital Pressure Indicator. GE Sensing & Inspection Technologies. Features

OMCL Network of the Council of Europe QUALITY ASSURANCE DOCUMENT

Bubble Point / Pressure Decay Test / Gas Transport Rates through Membranes

ONH836 Series: Oxygen/Nitrogen/Hydrogen by Inert Gas Fusion

Improve Process Reliability

Setting a New Standard in Flash Chromatography Performance

Complete Range of Force Tensiometers

Organic Elemental Analysis Series II CHNS/O Elemental Analyzer. proven performance. reliable results

CAPITAL CONTROLS SERIES NXT3000

The instrument should have a mass range from 2 to 2000 m/z or better Interface

STANDARD OPERATING PROCEDURES

Ultra High Purity Model 780S

Application Note. Rapid performance verification of AZURA systems with refractive index detector. Summary. Introduction

VIAFLO 96. Electronic 96 Channel Hand Held Pipettor

LPS Product Guide. LPS Series Nitrogen Generators. N2-GEN LPS TM - Layup Protection System Copyrighted All Rights Reserved

Series 7250 Ruska High-Speed Digital Pressure Controller. GE Sensing. Features

Markes Thermal Desorption Systems Site Preparation Page 1 of 8

SUPERIOR RESULTS WITH UNIQUE FEATURES

Capital Controls Series NXT3000 Modular design gas feed system with self-contained automatic switchover capability.

GCMSD-Headspace Analysis SOP

BETTER SAMPLE CARE. Spark Holland introduces. SPH1299 UHPLC Gradient Pump

High Automation of Thermo Scientific FlashSmart CHNS/O Analyzer using the MultiValve Control (MVC) Module

Features. Main Voltage: Vdc. Input Control Signal: 0-5 Vdc or 4-20 madc (Sourcing) Monitor Output Voltage: 0-5 Vdc or 4-20 madc (Sourcing)

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment Varian 310

Porter Analytical & Industrial Products

7250 Sys. Ruska Multi-Range Pressure Calibration System. GE Sensing & Inspection Technologies. Features. Applications

ON736 Series: Oxygen/Nitrogen by Inert Gas Fusion

Gases&Technology. Measurement of Impurities in Helium Using the Dielectric Barrier Discharge Helium Ionization Detector. FEATURE.

Site Preparation Specification for GCMS system. Dimensions and Weight. Agilent 7820MSD Series G3175A (G7020A), G3176A (G7021A)

ASTM 3612/TOGA/Dissolved Gas GC Revised October 2013

6890 GC Site Preparation

Specifications...Easy CLIA Classification: Sample Type: Blood gas analyzer operation has never been simpler Sample Size: Measured Parameters PCO2

Automated Liquid Handling Station

M-CTE250(T)(i) TM. Micro-Chamber/Thermal Extractor Operator Manual. Version February 2012

Customer Responsibilities

Pneumatic high-pressure controller Model CPC7000

DOS in Food Science & Nutrition, Manasagangotri, Mysore

Thermo Scientific Chromatography Well Plates

Thermo Scientific Chromatography Well Plates

Code Basic module and level control complete with optionals code

Quadruple mass spectrometers (transducer type)

AC : MEASUREMENT OF HYDROGEN IN HELIUM FLOW

CORROSION AT THE AIR-WATER INTERFACE REMOVE THE GAS

Automatic Isokinetic Sampler. ST5 Evo

Applied Compression s nitrogen generator packages offer users a cost-effective alternative to costly bottled nitrogen.

TA Instruments Installation Requirements for the Thermal Discovery Series

Customer Responsibilities

STANDARD OPERATING PROCEDURES

FROG-4000 TM Chemical Analysis System

ID-Cube. Installation and Operations Manual For ID-Cube Source and Power Supply. Revision 2 Document #:

Autocalibration Systems For In Situ Oxygen Analyzers

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

DF-550E PROCESS ANALYSERS APPLICATIONS FEATURES

LUMAZOTE T ECHNICAL BRO CHU RE

Vapor Intrusion. Sampling Solutions VAPOR INTRUSION. Sampling Solutions

Your local gas generation partner. Precision series Modular gas generation solution for GC.

The Air Liquide Gas System Equipment Brochure

/ /

WHEATON. Peristaltic Pumps. Advancing the Science of Liquid Handling

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS

Miniature Electronic Pressure Controllers. Precision Fluidics

FAS-W. Features. Applications. Automatic condensation hygrometer

Organic Elemental Analysis Series II Nitrogen Analyzer. proven performance. reliable results

TANK MANAGER FOR TWO TANKS OPERATING MANUAL. 10/31/11 C-More T6C L color touch panel

Technical Data Sheet High Performance Digital Gas Mass Flow Meters and Controllers Features Description

Discovery HP-TGA 75/750. Site Preparation Guide

High Pressure Asher HPA-S

Your local gas generation partner. Precision series Modular gas generation solution for GC.

4-7 kw/ hp. Dual Output Compressors (Air/Nitrogen) Driving Nitrogen Forward

Life Sciences. Pressure control solutions for your industry.

METHOD 204F--VOLATILE ORGANIC COMPOUNDS CONTENT IN LIQUID INPUT STREAM (DISTILLATION APPROACH) 1.1 Applicability. This procedure is applicable for

Transcription:

Versatility Accuracy Compact Versa Automated Headspace Vial Sampler

Small Size. Big Value. Automated Static Headspace System Static headspace is one of the most popular techniques due to its versatility for analyzing volatile organic compounds (VOCs) in a complex variety of matrices. This is due to the elimination of tedious sample preparation steps and prevents contamination problems that are common to other sample introduction techniques. Teledyne Tekmar draws on our experience as a leader in low-level VOC analysis with the introduction of this companion autosampler to the Headspace product line. Versa is the perfect solution for applications which require all the advantages of headspace analysis and is economical to fit any budget.

Advantages of the Versa Small on size yet big on value (only 12 wide) 20-position autosampler/single position platen oven for static sampling analysis of 22 ml vials Sample heating to 200 o C throughout pathway Built-in pressure control to ensure consistent volume for all samples regardless of external conditions Inert sample pathway including transfer line, sample needle, and loop provide superior analytical results by eliminating adsorption and reducing carryover Automatic Leak Check and Benchmark test for quick troubleshooting Simple method development using Method Optimization Mode (M.O.M.) Versa TekLink 2G software for use as standard or full 21 CFR compliance

Applications and Industries The Versa can quickly and accurately identify residual solvents in bulk or finished pharmaceuticals as prescribed in the United States Pharmacopeia (USP) and it meets all of the guidelines per USP Method <467>. Other applications include: Dissolved Gas Analysis per Method RSK-175 Contaminants in packaging materials Volatile Organic Compounds (VOCs) in drinking water, wastewater, and soils Screening of high level samples with EPA Method 5021 China Environmental Method GB-5749 Flavor and Fragrance profiling Forensics and Toxicology Residual Solvents per USP <467> This static flow diagram shows the system in a standby mode in which the loop and needle are continuously swept with an inert gas to ensure cleanliness between samples.

Walk-away Automation Inert Sample Pathway 21 Deep 12 Wide Vial Cover (Optional)

VOC TekLink 2G Fully Optimized User Interface Versa comes with easy-to-use and proven TekLink 2G software that operates from Windows XP or higher and includes 21 CFR compliance tools. All instrument parameters, method scheduling and editing can be programmed. Schedule Screen - Versa TekLink 2G is capable of performing useful diagnostics such as a Leak Check and Benchmark test. The Benchmark screen contains an interactive program that tests the Versa components including heaters, LEDs, valves, and the continuity of inputs and outputs. Diagnostics Screen - Developing a new method to achieve the best analytical results for an application can be both difficult and time consuming. With M.O.M., the analyst can optimize different method variables such as platen temperature, sample equilibration time, pressurization, mixing, loop fill, and inject times in order to substantially shorten the time required for method development. The method starts with a value and the parameter of choice will increment during the optimization process. For example, a value of 10 will increment the platen/sample temperature by 10 o C for every sample. The first sample will be heated to 50 o C, the next sample at 60 o C, and so on.

Versa Specifications Autosampler Capacity 20-Position Platen Heater Single position; ambient to 200 C via resistance heater settable in 1 C increments Vial Size 22 ml vials Sample Loop Ships with a standard 1 ml Silco coated loop. Other optional loop sizes include 100, 250, 500 µl as well as 2, 3, and 5 ml Sample Mixing System allows variable power settings from low / medium / high Sample Pathway SilcoNert 1000 tubing. Entire sample pathway temperature controlled up to 200 C Software GC Interface Pressure Control Valving Versa TekLink 2G software in a Windows XP or greater environment via USB connection Versa TekLink 2G can be configured for full 21 CFR Part 11 compliance tool capability Interface to virtually all commercially available GC instruments. Supplies or accepts GC and Data System start/ready signals via software selectable GC/IO configuration Software has the ability to control pressure to ensure consistent volume regardless of external conditions for all samples via a pressure transducer Motor-actuated 6-port valve with removable rotor (controlled from ambient to 200 C) Voltage Requirements 100/115 VAC ±5%, 50/60 Hz, 5 amps & 220/240 VAC ±5%, 50/60 Hz, 2.5 amps Gas Requirements Ultra-high purity (99.999%) Helium or Nitrogen; incoming pressure: 45-140 psig Unit Dimensions (H x W x D) 21 in (53.34 cm) x 12 in (30.48 cm) x 21 in (53.34 cm) Weight 40 lbs (18.14 kg) Environmental Conditions Operating Temperature: 10 to 30 C; Storage Temperature: -20 to 60 C; Relative Humidity: 10% to 90% Corrosion Resistance The chassis and carousel tray are resistant to aqueous samples with ph range 1-10 Windows is a registered trademark of Microsoft, SilcoNert 1000 is a registered trademark of SilcoTek. TekLink is a registered trademark of Teledyne Tekmar.

www.teledynetekmar.com 2015 Teledyne Technologies Incorporated 4736 Socialville-Foster Rd. Mason, OH 45040 USA Phone: (513) 229-7000 90023_9/17