Calibration Procedure

Similar documents
Calibration Procedure

DeFelsko PosiTector CMM IS Probe

Calibration Procedure

Calibration Procedure

PosiTector UTG, UTG-STD & UTG-ME

DeFelsko PosiTector Dew Point Meter DPM & DPMD Probes

Calibration Procedure. PosiTest DFT Combo

Calibration Procedure

DOscan10 Pocket Dissolved Oxygen Tester Instruction Manual

Bante810 Benchtop Dissolved Oxygen Meter Instruction Manual

VITLAB Volumetric instruments

Relative Humidity Calibration Kit

BI-680 Online Dissolved Oxygen Controller Instruction Manual

PREPARED BY: Marshall K. Cheung, Ph.D., Laboratory Director. REVISED BY: Marshall K. Cheung, Ph.D., Laboratory Director

Water Quality Monitoring Using a Handheld Sonde for in situ Measurements Date Prepared: 11/17/2017

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

User Manual Pocket Pro + Multi 1

Relative Humidity Calibration Kit

Vaisala Pressure, RH & Temp. Transmitter. The instrument was operational upon receipt. The instrument was adjusted and calibrated.

Owner s Manual Humiport 10/20

Heavy Duty Dissolved Oxygen Meter

EC214 EC215 - EC215R Bench Conductivity Meters

Bante820 Portable Dissolved Oxygen Meter Instruction Manual

Dissolved Oxygen/Temp Waterproof Tester

QUICK START GUIDE TO DRINKING WATER MONITORING

BIOGAS COMBUSTION PLANT MAINTENANCE MANUAL

Simple, Robust, Reliable Measures ph Doses either acid (lower) or alkali (raise) Displays ph, Total Dose Count (DCT) and Dose Count per hour (DC/h)

Bante821 Portable Dissolved Oxygen Meter Instruction Manual

Health & Safety data sheet According to EC Directive 91/155/EC and following amendments

MA PHIT- Food Certificate Program

! Warning, refer to accompanying documents.

Vapor Sorption Analyzer

HEATEC TEC-NOTE Publication No Revised

Free Chlorine Sensor For additional information, please visit our website at

Nuclear Associates

JOLLY2. Installation user s manual. 6 different operating modes selectable. version 3.3. DATA TO BE FILLED OUT BY THE INSTALLER (Page 1)

Psyclone TM. Protimeter Thermo-Hygrometer. GE Sensing. Operating Manual. INS7800, Rev. A (September 2007)

HI 2314 HI 2315 HI 23151

FAULT CODE TROUBLESHOOTING INDEX

CHM 100 / Introductory Laboratory Experiment (r10) 1/11

Soil Water Characteristic Curve (SWCC) Using the WP4C

2014 Programme of Training Courses in Measurement & Calibration

Improve Process Reliability

Bristol Fire Department Standard Operating Procedures. Multi Gas Detector

GE Measurement & Control

SS32L Dissolved O 2 Probe

Table of Contents. Sensor Calibration and Troubleshooting CDS4000 CO 2. Introduction 1. Handling Information. Calibration 2.

Operating Manual. BACVis. Manual BACVis. for. Sensors and MilliGascounter. Rev

A180 DO/BOD/OUR/SOUR Meter Instruction Manual

CHM Introductory Laboratory Experiment (r17sd) 1/13

HI 9932 Autoranging Bench Microprocessor EC/TDS/NaCl/ C Meter

PRODUCT SHEET. Order probe only as RXPROBE02

Liquid Handling Systems

THE UNIVERSITY OF NEWCASTLE - DISCIPLINE OF MEDICAL BIOCHEMISTRY

SPECIFICATIONS APCEPH1

Measuring the Conductivity of Pure Water Using USP<645>

Laboratory practice. Preparation and use of an ice point bath as a reference temperature. Document number TE-LP-001. Version: 07

ali-q TM Gravimetric Verification Procedure

Instruction Sheet. Important Note: Information that requires special emphasis. Note: Information that supplements points in the main text.

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

Chapter Pipette service & maintenance. Pipette specifications according to ISO Repair in the lab or return for service?

Transferpette. Testing Instructions (SOP) 1. Introduction. October 1998

Testing of Active Flow Control actuators at harsh environment

REFER TO AQUATHERM TECHNICAL BULLETIN A-AQTTB FOR ADDITIONAL INFORMATION AND SAFETY PRECAUTIONS

Contacts. Quick Start Guide

Thermo Environmental 48C Carbon Monoxide QA Plan Section I Electronic Calibration Branch Responsibilities

Operation Manual. Pro CO. Carbon Monoxide Analyzer. Rev

NOVALYNX CORPORATION MODEL RAIN GAUGE CALIBRATOR INSTRUCTION MANUAL

Technical Procedure for General Laboratory Equipment

2B Technologies, Inc.

Installation Instructions

INDUSTRIAL HYGIENE GROUP Standard Operating Procedure. TVA-1000 PID/FID Portable Toxic Vapor analyzer. 1 of 9. Contents

Installation Instructions

Transferpette. Testing Instructions (SOP) 1. Introduction. May 2009

Using the UltraRAE. Firmware 2.35

Instruction Manual HI Portable Waterproof Dissolved Oxygen Meter.

Management Plan for Confined Spaces

OxyScan Graphic. Operating Instructions. UMS Micro-oxygen sensor 501. Microprocessor instrument

Version BA D

ACV-10 Automatic Control Valve

TR Test Report Complementary Testing RKN e1 Container (+5 C) Protection by Insulation Version: 01 Page: 2 (22)

Trion PECVD SOP IMPORTANT: NO PLASTIC, TAPE, RESISTS, OR THERMAL PASTE ARE ALLOWED IN THE CHAMBER

COSMO INSTRUMENTS CO., LTD.

ISE-730 Oxygen Electrode and DO2-100 Currentto-Voltage

Title: Xactix XeF2 Etcher Semiconductor & Microsystems Fabrication Laboratory Revision: A Rev Date: 03/23/2016

FOOD INTAKE MONITOR. Hardware and Software User s Manual DOC-047 Rev 3.0. Copyright 2009 All Rights Reserved

DO NOT PRINT THIS PAGE

Instruction Manual. Multiparameter Benchtop Meter

COMBAT SWIM BOARD. RJE International, Inc. RJE International January 16, TAC-300 Revision 4

Standard Operating Procedure

VARIABLE TEMPERATURE HOT AIR GUN VALIDATION

Manual Weighingblock VB2 series and Uniscale

Simrad GD10P Extended On-site Maintenance

NEULOG OXYGEN LOGGER SENSOR GUIDE

Verification Of Calibration for Direct-Reading Portable Gas Monitors

Transferpette -8/-12

Elcometer 138. Bresle Kit and Patches. Operating Instructions

Digital Melting Point Apparatus

The Oxygen Sensor can be connected to all types of einstein Tablets, einstein LabMate, and einstein LabMate +.

Siting classification for Surface. Michel Leroy, Météo-France

Transcription:

Management Procedure 2557 Revision: B Date Issued: September 20, 2016 Date Revised: March 13, 2018 Calibration Procedure PosiTector SST Soluble Salt Tester Table of Contents 1 Introduction and UUC Performance Requirements... 2 Table 1-1... 2 2 Measurement Standards and Support Equipment Performance Requirements... 2 Table 2-1 UUC Accuracy Requirements and Description... 2 Table 2-2 Minimum Use Specification... 2 Table 2-3 Actual Equipment Specification... 3 Table 2-4 Calibration Environmental and Warm-up Requirements... 3 3 Preliminary Operations... 3 4 Calibration Process... 4 5 Performance Requirements... 5 Table 5-1 Performance Requirements and Calibration Data... 5 for PosiTector SST... 5 Management Procedure 2557 Rev B Page 1 of 6

1 Introduction and UUC Performance Requirements 1.1 This procedure describes the calibration of DeFelsko Corporation PosiTector SST probe and gage. Table 1-1 Models Measurement Range 0.0 1500 µs/cm PosiTector SST 0.0 50.0 o C 1.2 The unit being calibrated will be referred to as the UUC (unit-under-calibration). 2 Measurement Standards and Support Equipment Performance Requirements 2.1 The UUC accuracy requirements are based upon the published UUC performance specifications. 2.2 The test uncertainty ratio applied in this Calibration Procedure is 4:1 unless otherwise stated. The 0.0 200 µs/cm range has a 2.5:1 test uncertainty ratio. 2.3 The Minimum-Use-Specifications are the minimum test equipment specifications required to meet all the UUC accuracy requirements and the test uncertainty ratio applied. Table 2-1 UUC Accuracy Requirements and Description UUC Parameter Performance Specifications Test Method 0.0 200 µs/cm ± 2 µs/cm >200 600 µs/cm ± 10 µs/cm Compare to Standard Solution >600 1500 µs/cm ± 20 µs/cm 0.0 50.0 o C ± 0.5 o C Digital Thermometer Table 2-2 Minimum Use Specification Parameter Range Accuracy 0.0 200 µs/cm ± 0.5 µs/cm >200 600 µs/cm ± 2.5 µs/cm >600 1500 µs/cm ± 5.0 µs/cm Solution 0.0 50.0 o C ± 0.125 o C Management Procedure 2557 Rev B Page 2 of 6

Table 2-3 Actual Equipment Specification Manufacturer/Model Parameter Range Accuracy # s Applicable 84 µs/cm ± 0.8 µs/cm Hanna Instruments HI6033 500 µs/cm ± 2.0 µs/cm Ricca Chemical 2241 1413 µs/cm ± 5.0 µs/cm Hanna Instruments HI7031 Solution Room ± 0.05 o Control Company C 6412 Caution: The instructions in this Calibration Procedure relate specifically to the equipment and conditions listed in Section 2. If other equipment is substituted, the information and instructions must be interpreted accordingly. Table 2-4 Calibration Environmental and Warm-up Requirements Measurement Standards & Support Equipment : 23 ± 2 C. Environmental Requirements: Relative Humidity: 40-60% Measurement Standards & Support Equipment Warm-up and Stabilization Requirements: Not Required 3 Preliminary Operations Note: Review the entire document before starting the calibration process. 3.1 Visual Inspection 3.1.1 Visually inspect the UUC for, but not limited to: Dirty or contaminated test cell Probe damage 3.1.2 Damage or excess wear shall be repaired prior to beginning the calibration process. 3.1 For product returned for service, ensure the gage has been updated with the most recent firmware. 3.2 Gage Reset 3.2.1 When the unit is powered down, simultaneously hold the + and middle buttons until the reset symbol (2 arrows) appears. 3.3 On the Gage body menu navigate to the Setup menu, select Hi Res then select Exit Management Procedure 2557 Rev B Page 3 of 6

4 Calibration Process Note: Do not place any objects in the sensor cell. Do not blow into the sensor cell. Do not touch the tip of the conductivity standard or deionized water spouts with exposed skin. Make sure the conductivity standards and probe have had a chance to reach room temperature. To reduce temperature effects, touch the probe as little as possible. 4.1 Review the Performance Requirements Table 5-1. Note: Whenever the test requirement is not met, verify the results of each test and take corrective action before proceeding. 4.2 4.2.1 Place the UUC such that the probe is over a container that can collect the liquids that will spill. 4.2.2 Fill the probe test cell to over flowing with the 84 µs/cm conductivity standard and empty it out. Do not take a reading. 4.2.3 Repeat step 4.2.2 a second time. 4.2.4 Fill the probe test cell a third time and verify there are no air bubbles in the test cell. 4.2.5 Record the γ reading, in µs/cm, as displayed on the UUC. 4.2.6 Repeat steps 4.2.2-4.2.5 using the 500 µs/cm standard solution and again with the 1413 µs/cm solution. 4.2.7 Record the conductivity value and lot numbers from the certificates of analysis for the conductivity solutions. 4.2.8 Rinse the test cell with deionized water. 4.3 Solution 4.4 Place at least the entire white plastic tip of the UUC probe in an insulated chamber containing the reference temperature probe. 4.5 After at least 30 minutes record the UUC and reference probe readings. Management Procedure 2557 Rev B Page 4 of 6

5 Performance Requirements Table 5-1 Performance Requirements and Calibration Data for PosiTector SST Reference UUC Parameter Value Min 1 Reading Max 2 Lot Number Solution N/A 1) 84.0 µs/cm min= reference value - 2.0 µs/cm 500 µs/cm min = reference value - 10 µs/cm 1413 µs/cm min = reference value - 20 µs/cm = reference value - 0.5 o C 2) 84.0 µs/cm min= reference value + 2.0 µs/cm 500 µs/cm min = reference value + 10 µs/cm 1413 µs/cm min = reference value + 20 µs/cm = reference value + 0.5 o C Note: Do not write in this procedure. Management Procedure 2557 Rev B Page 5 of 6

Management Procedure Change Notice Procedure Number: MP 2557 Revision Level: B Date of Change: March 13, 2018 Title: Calibration Procedure, PosiTector SST Soluble Salt Tester Reason for Change: Increased measurement range of SST Description of Change: Change 0.0-199.9 range to 0.0-200 Changed 200 500 range to >200 to 600 Added range from 600 1500us/cm Updated tables 1-1, 2-1, 2-2, 2-3 and 5-1 I confirm I have read and understand the procedure and the change described above. Printed Name Signature Date Management Form 0010.02-05/1998 Management Procedure 2557 Rev B Page 6 of 6