BAPI Pressure Line of Products - FAQs

Similar documents
Installation and Operation Manual

2600T Series Pressure Transmitter Models 264DC Differential and 264HC Gage Level Transmitters. Kent-Taylor

Precision pressure sensor Basic version Model CPT6020

ATM - Analog Pressure Transmitter

AMS 6916 Board mount pressure sensor with ratiometric analog output

ATM.ECO - Analog Pressure Transmitter

Additel 761 Automated Pressure Calibrators

COMPARISON OF DIFFERENTIAL PRESSURE SENSING TECHNOLOGIES IN HOSPITAL ISOLATION ROOMS AND OTHER CRITICAL ENVIRONMENT APPLICATIONS

How to specify a product. Process Sensors and Mechanical Instruments

L 100. Bubble-Tube Level System. Installation, Operation and Maintenance Instructions

Programmable pressure and temperature transmitters PTM/RS485

DPC-30 DPC-100. Reference Manual

Parametrable / Programmable Pressure Transmitter

Programmable pressure and temperature transmitters PTM/RS485

3.0 Pressure Transmitter Selection

Programmable Submersible Level Transmitters

P9000 DESCRIPTION. For parts requiring RoHS compliance, please contact factory. P February /6

ATM/Ex - Analog Pressure Transmitter

Pressure Transmitters 36 F-27839

Additel 761 Automated Pressure Calibrators Selection Guide

BS12N Piezoresistive OEM Pressure Sensor

Sensoric 4-20 ma Transmitter Board Operation Manual

ATM.1ST. Pressure transmitters CUSTOMER BENEFITS

Type N-10, N-11 Hazardous Area Non-incendive Transmitters

AMS 6915 Board mount pressure sensor with digital output (I²C)

Additel 761 Automated Pressure Calibrators

7250 Sys. Ruska Multi-Range Pressure Calibration System. GE Sensing & Inspection Technologies. Features. Applications

Additel 761 Automated Pressure Calibrators Selection Guide

ATM/Ex - Intrinsically Safe Analog Pressure Transmitter - ATEX / IECEx Certified

ATM/GR. Electronic pressure switches CUSTOMER BENEFITS

Additel 761 Automated Pressure Calibrators

The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions

ATM.ECO/IS - Analog Transmitter with Temperature compensation

Cover Page for Lab Report Group Portion. Pump Performance

USING THE CS400/CS405 (KPSI SERIES 169/173) SUBMERSIBLE PRESSURE TRANSDUCER WITH CAMPBELL SCIENTIFIC DATALOGGERS INSTRUCTION MANUAL

UNIK 5600/5700 Marine Certified Pressure Sensing Platform

ACCURACY, PERFORMANCE, AND HANDLING OF OIL-FILLED DIGIQUARTZ PRESSURE INSTRUMENTATION

PRESSURE SENSOR - ABSOLUTE (0 TO 700 kpa)

BS12 Piezoresistive OEM Pressure Sensor

The Ins and Outs of I/P Transducers

ASDX Series Silicon Pressure Sensors

DTG - LCD Digital Temperature Gauge USER MANUAL

High-performance submersible pressure transmitter For level measurement Model LH-10

Improving distillation tower operation

9700 Transmitter Submersible hydrostatic level transmitter

Instruction Manual Differential Pressure Transmitter

P499 Heavy Duty Pressure Transducer

SX150A. Features. Typical Applications. Description

AMS 2710 PCB pressure sensor module with V output

Series 7250 Ruska High-Speed Digital Pressure Controller. GE Sensing. Features

628 Differential Pressure Decay Leak Tester

Pneumatic high-pressure controller Model CPC7000

AFC. SDPROC and AFC Analog Mass Flow Controller ANALOG MASS FLOW CONTROLLERS. Principles of Operation. Design Features

Pressure Sensor Bridge Configurations

Instrumentation & Data Acquisition Systems

Installation, operating and maintenance Instructions for Seemag bypass level indicator

Technical Note. PendoTECH Single Use Pressure Sensors: Calibration, Accuracy, and Implementation. Introduction

CDS-2000 CO 2 Sensor Verification, Calibration, and Troubleshooting Bulletin

Differenz-Drucktransmitter Differential pressure transmitter Transmetteur de pression différentielle bar

BAROMETER PRESSURE STANDARD PRESSURE CONTROLLER

ADT 761 Automated Pressure Calibrator

Additel 780 Series Pressure Controller

Operating Instructions for Intrinsically Safe Pressure Transmitters Series DMG/******** for Hazardous Application in Coal Mining Industry

APG. Intrinsically Safe, Heavy Duty Pressure Transducer Series: PT-400

Pressure Measurement

Hand-held pressure calibrator with integrated pump Model CPH6600

SPD Pressure Sensor Families

deltaflowc deltaflowc Venturi or Probe

Series Ruska Digital Pressure Indicator. GE Sensing & Inspection Technologies. Features

High-performance submersible pressure transmitter For level measurement Model LH-10

Additel 780 Series Pressure Controller

I/P Transducer Positioner Module

Lab 1c Isentropic Blow-down Process and Discharge Coefficient

PM105 PRESSURE METER USER S MANUAL

Pressure Measurements

Pneumatic high-pressure controller Model CPC7000

DPI 610/615 Series. Druck Portable. Pressure Calibrators. GE Sensing. Features. Setting the Standard for Portable. Pressure Calibrators

TEK-SUB 4800B. Submersible Level Transmitter. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys LEVEL

ATM.1ST/Ex - High Precision Transmitter

Design Features. General Description

Automatic Isokinetic Sampler. ST5 Evo

Differential Pressure Transmiter

Cover Page for Lab Report Group Portion. Head Losses in Pipes

Amplified Middle Pressure Sensors

UNIK 5600/5700. Marine Certified Pressure Sensing Platform. High Quality. Features. Bespoke as Standard. Expertise. bhge.com

INDUSTRIAL. Pressure Transmitters. Product Guide. Low cost to high accuracy portfolio. Ranges from 70 mbar to 1400 bar. Flexible, rugged and reliable

Lab 1: Pressure and surface tension. Bubblers, gravity and the mighty paper clip.

The Discussion of this exercise covers the following points:

Specifications and information are subject to change without notice. Up-to-date address information is available on our website.

UNDERSTANDING, ACCELERATED

Radar, Ultrasonic and RF Level Transmitters

HTD series digital differential pressure sensors

O3 3E 1 F Gas Sensor Module

[Instruments for vacuum measurement, checking and adjustment] 3

SITRANS P measuring instruments for pressure

INSTRUCTION MANUAL MP4AR Remote Convection Gauge Range: 1 x 10-3 Torr to 1 x 10+3 Torr

SPD310/SPD360 Air Differential

OPTIMA 7 - BIOGAS Calibrating the gas sensors SENSOR ADJUSTMENT. Diamond Scientific 625 Peachtree St., Cocoa, Florida /Tel:

DeltaSpan Pressure Transmitters LD10 Series Owner s Manual

ACCURATE PRESSURE MEASUREMENT FOR STEAM TURBINE PERFORMANCE TESTING

Transcription:

Table of Contents 1. Several manufacturers produce pressure transmitters, why should I purchase from BAPI?... p. 2 2. BAPI makes several styles of pressure transmitters. What are the features of each?... p. 2-3 3. What is inches of water column?... p. 4 4. Why use inches of water?... p. 4 5. What is differential pressure?... p. 4 6. How is differential pressure measured?... p. 4 7. How is accuracy calculated with sub-ranges?... p. 4 8. What is burst pressure?... p. 4 9. What is proof pressure?... p. 4 10. What is bidirectional pressure?... p. 4 11. What is Auto-Zero?... p. 4 12. What is absolute pressure?... p. 4 13. What is gauge pressure?... p. 4 14. What is static pressure?... p. 4 15. What is velocity pressure?... p. 4 16. What is total pressure?... p. 4 17. What does temperature error mean?... p. 5 18. Are BAPI pressure transmitters able to withstand electrical interference, such as EMI/RFI, transient and ESD?.. p. 5 19. When I turn on my pressure transmitter, I get 2.5V on the analog output with zero applied pressure. Why?.. p. 5 20. What pressure measurement units are the transmitters calibrated to?... p. 5 21. How often do BAPI pressure transmitters need to be recalibrated?... p. 5 22. Are zero and span adjustments available on BAPI pressure transmitters?... p. 5 23. What does long-term stability mean and how does it affect the measurements?... p. 5 24. How do I know what pressure range to use?... p. 6 25. Is National Institute of Standards and Technology traceability available for BAPI Transmitters?... p. 6 26. May the published pressure and temp specifications for BAPI pressure transmitters be safely exceeded?... p. 6 27. Why do you recommend that pressure transmitters be mounted with the ports down?... p. 6 28. What does Bidirectional Pressure Measurement mean?... p. 6 29. Can Differential Pressure Transmitters be used for measuring Suction Pressure?... p. 6 30. What length of tubing may I attach to the transmitter s pressure ports?... p. 6 31. What if I need a pressure range that s not in your catalog?... p. 6 32. Will the pressure transmitter work properly if the supply voltage is slightly below the minimum specified level?.. p. 6 33. Where are BAPI s products made?... p. 6 34. How do I get more information?... p. 6 Pg. 1

1. Several manufacturers produce pressure transmitters, why should I purchase from BAPI? BAPI manufactures high quality pressure transmitters at affordable prices. BAPI uses state of the art monocrystalline silicon capacitive transducers. These transducers have very low inherent drift and imperceptible span shifts. BAPI s computer controlled calibration equipment provides pressure transmitters with unsurpassed accuracy. Each transmitter comes with a free NIST traceable certificate of accuracy. If you ever misplace the certificate, BAPI can replace it when you provide us with the pressure transmitter s serial number. BAPI knows the difficulties that field technicians face when troubleshooting mechanical equipment malfunctions. BAPI s pressure transmitters have displays that allow them to be used as test instruments. A simple glance will tell you if you are in or out of the calibrated range. BAPI manufactures a pressure transmitter for every air-side application. ZPS (Zone Pressure Sensor) or BAPI-Box Pressure The original ZPS was the industry s first multi-range pressure transmitter. DIP switches allow the field technician to select one of 10 precision calibrated pressure ranges and one of 3 output ranges. ZPS-EZ (EZ Mount Enclosure) or EZ Pressure The ZPS-EZ is optimized for equipment or control panel mounting. 10 field selectable pressure ranges and 3 output ranges allow the flexibility to pick what s needed for a particular application. It is available in the EZ mount enclosure for 2.75 snaptrack, 35 mm DIN rail, or mounting to any surface. ZPT (Zone Pressure Touch) or Touch Pressure The ZPT is the logical extension of the ZPS, with all the features of the ZPS and more. A touch button menu allows the field technician to select one of 20 precision calibrated pressure ranges, one of 5 output ranges, and even set the endpoints for a custom pressure range in the field. FRP (Fixed Range Pressure) The FRP is BAPI s pressure transmitter for cost conscious applications. One pressure range and one output range are selected at time of order. A multi-color LED indicates the applied pressure. Custom pressure ranges are available with NCNR minimum quantity orders. ZPM (Zone Pressure Multi-Sensor) BAPI s Zone Pressure Multi-Sensor is the most flexible pressure sensor on the market. Output, range, units, directionality, and response time are quickly set in the field with no tools, no power and no small components. Comes with 3 LEDs on the face of the unit to indicate when the pressure is Out of Range Low, In Range or Out of Range High. ZPS ZPS-EZ ZPT FRP ZPM 2. BAPI makes several styles of pressure transmitters. What are the features of each? ZPS Features Multi-range pressure transmitter for general pressure applications 3 pressure range models, all ranges within each model are field selectable via DIP switches High - 5 ranges between 0 and 30 W.C. or 0 and 7,400 Pa Three field selectable outputs: 4 to 20 ma, 0 to 5 VDC, 0 to 10 VDC Optional LCD aids in troubleshooting because it shows the entire operational pressure range of the unit regardless of the pressure range selected BAPI-Box enclosure with hinged cover ZPS Pg. 2

ZPS-EZ Features Multi-range pressure transmitter optimized for control panel mounting Two pressure range models, all ranges are field selectable within each model Three field selectable outputs: 4 to 20 ma, 0 to 5 VDC or 0 to 10 VDC Field selection is done via rotary switch, pushbutton and the display, no DIP switches Revolutionary EZ mount enclosure: 2.75 snaptrack, 35 mm DIN rail or surface mount. LCD aids in troubleshooting because it shows the entire operational pressure range of the unit regardless of the pressure range selected ZPT Features Multi-range pressure transmitter for general pressure applications Two pressure range models, all ranges are field selectable within each model Field selectable units of Pascal or inches W.C. Custom ranges can be created in the field Five field selectable outputs: 4 to 20 ma, 0 to 5 VDC, 1 to 5 VDC, 0 to 10 VDC or 2 to 10 VDC All ranges are field selectable through the front panel with a touch interface and the display ZPS-EZ Field selectable output dampening: Fast = 0.05 second time constant Slow 0.5 second time constant BAPI Box enclosure (Screw to any surface) LCD aids in troubleshooting because it shows the entire operational pressure range of the unit regardless of the pressure range selected ZPT FRP Features One factory set pressure and one factory set output range for specific applications. Sixteen ranges between -5 and +5 W.C. or -1,250 and +1,250 Pa A multiple color LED indicates pressure status Four outputs: 0 to 5 VDC, 1 to 5 VDC, 0 to 10 VDC, 2 to 10 VDC BAPI Box enclosure (Screw to any surface) Other mounting options are available, contact BAPI for details. ZPM Features Multi-range pressure transmitter optimized for control panel mounting Three pressure range models, all ranges are field selectable within each model High - 5 ranges between 0 and 30 W.C. or 0 and 7,400 Pa 3 LEDs on the face of the unit to indicate when the pressure is Out of Range Low, In Range or Out of Range High Five outputs: 0 to 5 VDC, 1 to 5 VDC, 0 to 10 VDC, 2 to 10 VDC, 4 to 20 ma All ranges and outputs and othe parameters are field selectable without power or tools FRP ZPM Pg. 3

3. What is inches of water column? An inch of water is the pressure exerted by a column of water one inch tall. There are 27.68 inches of water in one pound per square inch. Automobile tires at 32 psi pressure have a pressure of 885.76 inches of water. 4. Why use inches of water? Air supply ducts typically work at pressures of 0.75 to 2.5 inches of water. It is easier to say 1 inch of water rather than 0.036 psi. 5. What is differential pressure? Differential pressure is the pressure difference between two pressure sources. 6. How is differential pressure measured? The output is the difference from the high pressure port to the low pressure port. For example, if the high pressure port is connect to a pressure of 10 of water and if the low pressure port is connected to a pressure of 8 of water, then the transmitter s output is 2 inches of water. 7. How is accuracy calculated with sub-ranges? The accuracy of our differential pressure transducers include the non-linearity, hysteresis, and non-repeatability at 25 C. The accuracy specification is a percentage of possible error throughout the full range of the sensor. For example, a ±1.0 WC pressure transmitter with a ±0.25% accuracy specification could have an accuracy error up to ±0.005 WC. This accuracy error applies to all sub-ranges available within the sensor s range. Our pressure transmitters are calibrated and validated to be within accuracy specification. 8. What is burst pressure? Burst pressure is the maximum pressure that may be applied to the sensor without damaging the sensor. If this happens, a transmitter will need to be replaced. See product datasheet for details. 9. What is proof pressure? Proof pressure is the maximum pressure that may be applied without changing the transducer performance. If this pressure is exceeded, the transmitter will likely need factory recalibration. See product datasheet for details. 10. What is bidirectional pressure? Bidirectional pressure refers to pressure values above and below the pressure on the negative pressure port. The output signal is at the center of the range at zero differential pressure. 11. What is Auto-Zero? Auto-zero is the field calibration of the zero pressure output measurement. 12. What is absolute pressure? Absolute pressure is the pressure measured relative to a perfect vacuum. 13. What is gauge pressure? Gauge pressure is the differential pressure between the local ambient pressure and another pressure source. 14. What is static pressure? Static pressure is the pressure on the walls of a vessel at right angle to any flow. Static pressure is usually measured with a static pressure probe. 15. What is velocity pressure? Velocity pressure is the pressure caused by the momentum of moving air. Velocity pressure is usually measured with a Pitot tube assembly. 16. What is total pressure? Total pressure is the arithmetic sum of static pressure and velocity pressure. Total pressure is usually measured with a total pressure tube. Pg. 4

17. What does temperature error mean? Temperature error or compensated temperature range is an often misunderstood specification. This does not mean that there are no errors due to changing temperature, just that the errors are known, measured, and specified. BAPI s standard range pressure transmitters have the specification of 0.01% FS/ F (0.02% FS/ C) (±5.0 W.C. @ -4 to 140 F [-20 to 60 C]). This means that between -4 and 140 F, for every degree Fahrenheit away from 72 F, the output may shift from 0 up to ±0.01% of full scale. Below -4 F and above 140 F, the errors for BAPI pressure transmitters are not known. Refer to individual data sheets for product specification 18. Are BAPI pressure transmitters able to withstand electrical interference, such as EMI/RFI, transient and ESD? Yes, all of BAPI s pressure transmitters are certified to CE standards for electrostatic discharge, radiated susceptibility, electrical fast transient, surge, conducted immunity, voltage fluctuations, power frequency magnetic fields, and voltage dips. 19. When I turn on my pressure transmitter, I get 2.5V on the analog output with zero applied pressure. Why? When BAPI pressure transmitters are in bidirectional mode they measure negative as well as positive pressure. The 0 to 5V analog output is divided to swing from 2.5 to 0 volts when operating with negative pressure and 2.5 to 5.0 volts when operating with positive pressure. Zero pressure is at one-half the output range. 20. What pressure measurement units are the transmitters calibrated to? BAPI sells pressure transmitters calibrated in Inches of Water Column or Pascals. ZPS, ZPS-EZ, and FRP require either inches W.C. or Pascals to be specified at time of order. ZPT ships calibrated in both inches W.C. and Pascals and can be converted from inches W.C. to Pascals or back again in the field. Conversion factors 27.68 in W.C. = 1 psi 249.09 Pa = 1.00 in W.C. 0.001 Bar = 100 Pa 21. How often do BAPI pressure transmitters need to be recalibrated? For most applications performing an auto-zero whenever it appears that the transmitter has drifted is all that s required. For critical applications, the unit should be tested and zeroed 2-3 times a year. 22. Are zero and span adjustments available on BAPI pressure transmitters? Zero yes, span no. All BAPI pressure transmitters have a simple auto-zero process. To auto-zero connect the transmitter s high pressure port to the low pressure port with a short length of tubing. Press the auto zero button, flip the auto-zero switch, or select the Auto Zero menu, depending on model, and zero will be set in a few seconds. BAPI has had twelve pressure transmitters continuously powered since August 2008 and no identifiable shift in the span measurement has been revealed. Even though we are confident in the long-term reliability of our pressure transmitters, BAPI recommends making periodic inspections to check for damage. BAPI s technical service representatives will be happy to consult with you and make recommendations based on your requirements. 23. What does long-term stability mean? How does it affect the measurements? Lack of long-term stability manifests itself as zero pressure drift. Drift is normally associated with aging of electronic components, adhesive creep of strain gauges, or relaxation over time of tensioned diaphragms. BAPI s mono-crystalline silicon diaphragm is not tensioned and does not relax with age as metal diaphragms may do. BAPI s capacitive pressure sensing transducers do not use strain gauges, so there is no possibility of creep. Pg. 5

24. How do I know what pressure range to use? A pressure range of 1 ½ to 2 times the working pressure is generally selected. 25. Is National Institute of Standards and Technology traceability available for BAPI Transmitters? Yes. BAPI s instrumentation calibrations are traceable to NIST. 26. May the published pressure and temperature specifications for BAPI pressure transmitters be safely exceeded? Pressures up to the specified proof pressure may be applied without damage. Temperatures up to the specified storage temperatures may be applied without damage. If the unit is powered, the temperature compensation error is undefined between -40 F to -4 F and 140 F to 203 F (-40 C to -20 C and 60 C to 95 C). 27. Why do you recommend that pressure transmitters be mounted with the ports down? As long as an auto-zero is performed after installation, BAPI s pressure transmitters may be mounted in any orientation. BAPI recommends that the ports face down so that any condensation that collects in the tubing may not enter the transmitter. It is good practice to leave drip loops in the tubing just before the transmitter. 28. What does Bidirectional Pressure Measurement mean? The output signal is scaled over a pressure range which can vary with positive and negative pressures. For example; -1.00 in W.C. to +1.00 in W.C. = 0 to 10 Volts dc. 29. Can Differential Pressure Transmitters be used for measuring Suction Pressure? Yes, if the pressure transmitter has a positive range higher than the suction pressure, connect the negative side port to the suction pressure and leave the positive port open to ambient air pressure. 30. What length of tubing may I attach to the transmitter s pressure ports? BAPI has tested the ZPS family with 1,000 feet of tubing attached to the transmitter s positive pressure port and 1,000 feet of tubing attached to the negative pressure port simultaneously. No degradation in accuracy was detected. Response to pressure changes was slowed due to the length of tubing. 31. What if I need a pressure range that s not in your catalog? ZPS, ZPS-EZ, and ZPS-FR transmitters may all be ordered with custom pressure ranges, contact your BAPI representative for details. BAPI s ZPT allows custom pressure ranges to be field selected. Please see the Installation & Operation instructions or contact your BAPI representative for details. ZPM is fully field configurable to 10 defined ranges. Custom ranges can be special ordered. 32. Will the pressure transmitter still work properly if the supply voltage is slightly below the minimum specified level? BAPI does not recommend powering the pressure transmitter from power supplies lower than specified. 33. Where are BAPI s products made? Over 99% of BAPI s products are made in Gay Mills, Wisconsin, USA. If you are in the area, please feel free to stop by for a visit! See http://www.bapihvac.com/content/uploads/2011/07/bapi_buy_american_act.pdf for a full explanation. 33. How do I get more information? Call 1-608-735-4800 and speak to a BAPI Customer Service representative, Email sales@bapihvac.com, or go to our website and click on the chat button. Pg. 6