Thanks for choosing EJAI SOLAR product

Similar documents
Installation and commissioning instructions 255 series and 256 series

INSTALLATION & MAINTENANCE INSTRUCTION

INSTRUCTION MANUAL. January 23, 2003, Revision 0

JANIS OPERATING INSTRUCTIONS FOR SUPERCONDUCTING MAGNET CRYOSTATS

Installation, Operation, and Maintenance Manual

OPERATOR S MANUAL Ar-Gone Weld Gas Analyzer

Instruction Manual Updated 7/26/2011 Ver. 2.2

Pressure Dump Valve Service Kit for Series 2300 Units

UltRo Dual Flow Reverse Osmosis Water System

IMPORTANT PLEASE READ BEFORE COMMENCING INSTALLATION

Installation and Operation Manual for Solar Systems with KTU R Collectors

PX3005. Rangeable Industrial Pressure Transmitter M-5721/1018

Dilution Refrigerator manual

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual

Pressure Dump Valve Service Kit for Series 3000 Units

Discharge Relief Valve Operation & Maint.

Booster Regulator/Air Tank

Installation Instructions

High-performance submersible pressure transmitter For level measurement Model LH-10

Section 3- Repair and Calibration Procedures

INSTRUCTIONS FOR CONVERTING CONDENSING GAS MOBILE HOME FURNACES MODEL SERIES: CMA3*, CMC1*, VMA3*, VMC1*

INSTALLATION INSTRUCTIONS

OWNER S TECHNICAL MANUAL

RHPS Series RD(H)F40 User Manual. Read the complete manual before installing and using the regulator.

Table of Contents Want full page pictures with most important parts labeled in the beginning.

COMBINATION AIR RELEASE DEGASSING (CARD) VALVES INSTALLATION AND MAINTENANCE MANUAL

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

VACUUM REGULATORS CONTENTS

ENERGY BLADE 3K4. Energy Blade Installation Instructions

Solar Water Heaters for Swimming Pools

from Thames Cryogenics Ltd Total Cryogenic Solutions Cryogenic Cluster Day 22/09/2010

ACCESSORY KIT INSTALLATION MANUAL

APPS-160 Gen 2 User Manual

Operating Instructions Model and Hydrostatic Test Pump

TS1. Ultrasonic Tank Sender. Installation and Operating Instructions. For TS1 Firmware v3.8. Page 1 INST-TS1-V13 18/11/10

3/8" Dr. Air Butterfly Impact Wrench

Operating Instructions

HORIZONTAL BLADDER TANK

Installation, Operation and Maintenance Instructions for Pacific PA Non-Storage Heat Exchanger

Installation and operation Manual. Bermad Surge Anticipation Valve. Model No 435

SIMPLAIR PIPING TOOL. JXT Company

WATER MADE EASY MARINE ENERGY MUNICIPAL INDUSTRIAL

Combination Air Valve Model

Heat Pump Connections and Interior Piping

CSA Sample Draw Aspirator Adapter Operator s Manual

Series Environmental Chambers

Shut-Off Valves and Valve Boxes

How to specify a product. Process Sensors and Mechanical Instruments

ST 18 Aluminium Gas Model

DECLARATION OF INCORPORATION

Installation and operating manual. Pneumatic control station LK product no: PCS 1-10

Installation Instructions

Installation, Operation and Maintenance Instructions Buffer Vessel OM006

OPERATION MANUAL RTI RHS650 RTI TECHNOLOGIES, INC East Market Street York, PA Manual P/N

Installation Instructions

Atmospheric relief valve type 1100 Installation and maintenance instructions

Installation, Operation and Maintenance Instructions for Mild Steel Buffer Vessel

VERTICAL BLADDER TANK

SERIES 20 CHAMBERS THE RC-25 AND RC-25F CHAMBERS ASSEMBLY

ABB MEASUREMENT & ANALYTICS DATA SHEET. AP100 ph/redox (ORP) cartridge sensors with water-wash option

Hand Valve Series. Push-In Fitting Type Shut-off Valve (Residual Pressure Release Valve) Control Open/Close for Air Supply.

FITTINGS THREAD LUBRICANTS. Fittings 20,000 PSI

Operating Instructions Models and Hydrostatic Test Pumps

SEQUENTIAL SHOWER VALVE INSTRUCTION MANUAL PLEASE LEAVE THIS MANUAL WITH THE END USER

TOOL BOX 033- HOSEREEL SERVICE / FAULT FINDING

Conversion Procedure Manual For use with developing future iterations of MSD Project P13051

The Discussion of this exercise covers the following points:

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.

ANDERSON GREENWOOD SERIES 9000 POSRV INSTALLATION AND MAINTENANCE INSTRUCTIONS

OPERATION MANUAL NTF-15

ACCESSORY KIT INSTALLATION INSTRUCTIONS

Installation, Operation, and Maintenance Manual

with O 2 Controller Instruction Manual

Coiling Tube with Twist-Proof Fitting

Propane Conversion Kit Instructions

OPERATION MANUAL NTF-60 Plus

General No. 25 and D-25 Handy Operating Instructions

BASIN AND WALL MIXER INSTALLATION INSTRUCTIONS

RK LEL Sample Draw Aspirator Adapter Operator s Manual

LUBRICATOR ASSEMBLY AND OPERATING INSTRUCTIONS

ST 18 Aluminium Gas Model

Cold-acclimatised pipelines

Plasson Pressure Reducers & Pressure Regulators

Installation, operating and maintenance Instructions for Seemag bypass level indicator

Safety Aspects and Design of the Vent Isolation Chamber. Prepared: W.M. Snow Checked: H. Nann Approved: W. M. Snow

Hand lever valves VHER

Inflatable Packer Single & Double. Single & Double Packer Dimension. Wireline Packer. Water Testing Packer (WTP) Packer

Booster Pump PB4-60 Replacement Kits

Halsey Taylor Owners Manual

DPC-30 DPC-100. Reference Manual

INSTALLATION & MAINTENANCE INSTRUCTIONS - ORIGINAL VERSION AVK KNIFE GATE VALVES

Variable Temperature Storage Dewar Mount Inserts

FIK In-Tank Filters FIK. Max Flow: 170 gpm (643 lpm) Working Pressures to: Rated Static Burst to: Flow Range to:

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

Installation, Operation and Maintenance Manual for Back Pressure Regulator

Installation Instructions

Advanced Fluid Handling Cart Owner s Manual

Nickel-Plated Brass Right Angle Flow Control Valves NPTF/Inch Series GSCU, GMCU, GSVU, GMVU, GSCO, GMCO

System Pressure Manager Standard & System Pressure Manager Plus

Transcription:

SPLIIT SOLAR WATER HEATER (( YYJ--S01 SERIIES )) IINSTALLATIION MANUAL

www.ejaisolar.com ZHEJIANG EJAI SOLAR TECHNOLOGY CO.,LTD. 1 Thanks for choosing EJAI SOLAR product Content 1. Important Information....2 1.1 Local Standards 1.2 Local Standards 1.3 Pressure and Temperature Control and Relief 1.4 Hail Resistance 1.5 System Design and Installation 2. Unpack and inspection....3 2.1 Tube Inspection 2.2 Frame Inspection 3. Plumbing.....3 3.1 Plumbing Connection 3.2 Choice of Piping Material 3.3 Pressure Levels 3.4 Temperature Sensor Insertion 4. Stagnation and Overheating.. 4 5. Working principle of heat pipe vacuum tube solar collector.4 6. Collector installation....5-6 6.1 Installation Direction of collector 6.2 Installation Angle of Collector 6.3 Installation Steps 7. Circuit Installation Illustration....7 8. Liquid filling illustration....8-9 8.1 Liquid filling Steps 9. Illustration for the full system....9 10. Water tank Location.. 10 11. Insulation of the pipe..10

www.ejaisolar.com ZHEJIANG EJAI SOLAR TECHNOLOGY CO.,LTD. 2 1. Important Information 1.1 Local Standards Installation must be completed in accordance with the relevant local standards and regulations. 1.2 Qualified Installer Installation must be completed by qualified plumbing professionals. 1.3 Pressure and Temperature Control and Relief Solar loop should be designed for normal operaton at <600kpa via use of a pressure limiting (pressure reduction) valve on the mains cold supply line. System design must provide mean for allowing pressure release at no more than 800kpa (113psi) and hot water dumping from the solar loop or storage tank once the temperature reaches 99 (210 ). It is recommended that the lever on the pressure and temperature relief valve (PTRV) be checked once every 6 months to ensure reliable operation. It is important to raise and lower the lever gently. 1.4 Hail Resistance The glass evacuated tubes are surprisingly strong and able to handle significant impact stresses once installed. Testing and impact stress modeling proves that the tubes are able to withstand impact from hail up to 25mm/1 in diameter when installed at angle of 40 or greater. The ability of the evacuated tubes to withstand impact from hail is greater influenced by the angle of impact and so instanlling the collectors at low angles do reduce their impact resistance. However, even when laying flat, impact by hail up to 20mm/3/4 in size will not cause breakage. It is recommended that in areas prone to large hail ( >20mm 3/4 the solar collector should be installed at an angle of 40 or greater to provide optimum protection. As many resident areas in the world fall within the latitude of +30-70 this angle is generally a common installation one. 1.5 System Design and Installation Please read all installation instruction carefully before starting system design or installation. The system configuration may need to be customized to suit the specific requirements of the installation. Please ensure that any system designs to be suitable for certain installation.

www.ejaisolar.com ZHEJIANG EJAI SOLAR TECHNOLOGY CO.,LTD. 3 2. Unpack and inspection 2.1. Tube Inspection Open the tube carton which contains the evacuated tubes with heat pipes to check and make sure the evacuated tubes are all intact and the bottom of each tube is still in silver color. Do not expose the tubes to sunlight until installed otherwise the inner tube and heat transfer fin will become very hot. The outer glass surface will not become hot. 2.2 Frame Inspection Unpack the carton which packed with frame kit and manifold. If a flat roof frame or tile roof frame is being used those componenst is packed separately in the same carton. It might be necessary to purchase bolts or other fasteners to suit the installation surface. 2.3 Tank Inspection (This item only happen if you buy full system from us) Open the tank carton which contains tank to make sure there is no visible damage 2.4 Working station Inspection (This item only happen if you buy full system from us) Open the carton which contains working station to check the pressure gauge and controller. It must be intact. 3. Plumbing 3.1 Plumbing Connection Once the frame has been mounted and the manifold has been attached to the frame then the manifold header can be connected to the plumbing system. 3.2 Choice of Piping Material 12mm OD and 15 OD copper copper piping is generally used for most solar collector installations. As the flow rate is slow so large diameter pipe is unnecessary and will only increase system costs and heat loss. Ejai solar collectors come standard with two flexible SS pipes (not in all market). They are designed for connection to the manifold as they are easy to bend and pass through the roof. The end of the flexible pipe is either 1/2 for 3/4 BSP thread and so can accept standard male BSP thread fittings for connection to copper pipe. 3.3 Pressure Levels Regardless of installation configuration, pressure release value,expansion vessels and / or other pressure control devices must be installed. The solar loop should be designed to operate at no more than 800Kpa (PRV maybe 850 Kpa). (800Kpa = 8 bar = 116psi). For installation where mains pressure water is used the system should ideally be designed to operate at a pressure of <600kPA achieved by use of pressure limitation/reduction value. 3.4 Temperature Sensor Insertion

www.ejaisolar.com ZHEJIANG EJAI SOLAR TECHNOLOGY CO.,LTD. 4 The solar controller s temperature sensor should be coated with a thick layer of thermal paste and inserted into the sensor port to the full depth. If the fit is too loose, slide a piece of copper plate or wire in beside the sensor, seal the sensor port opeining with silicone sealant to prevent water ingress. Ensure that sensors used on the collector are high temperature rated (up to 250 /486 ) in particular the cable. 4. Stagnation and Overheating Stagnation refers to the condition that occures when the pump stops running due to pump failure, power blackout, or as a result of a high tank temperature protection feature build into the controller,which turns the pump off. If a PTRV is installed on the collector, steam will form in the header. Eventually some steam may feed back to the storage tank via the return line. The PTRV on the tank will open to release pressure or heat as required. Under such conditions the manfold will normally reach a maximum temperature of around 230 /446. Generally the heat returning from the collector in the form of steam is not enough to affect a continued increase in tank temperature (ie.heat input <tank heat losses). Under normal use stagnation should rarely occur as a result of pump stoppage,since power blackouts normally happen during storms and not clear sunny weather. High tan ktemperature protection should only occure when hot water is not used for several days(when on holiday), and only during strong periods of sunlight(summer). If leaving the house for a extended period of time (more than 2-3 days) it is advisable to cover the collector panel or design the system with a heat dissipation device or alternative use for the heat. Thus preventing overheating of the system and collector stagnation. Stagnation of the solar collector will NOT damage the solar collector,however insulation used on the piping close to the manifold inlet and outlet should be able to withstand temperature of up to 230 /446 (Eg. Glass wool or mineral wool with an exterior wrap of aluminum foil thus protection against the elements.) 5. Working principle of heat pipe vacuum tube solar collector

www.ejaisolar.com ZHEJIANG EJAI SOLAR TECHNOLOGY CO.,LTD. 5 The Heat pipe series solar collector are always connected with exisiting heating supply device. The selective coating on the inner cover of the evacuated tubes converts solar energy into heat energy and transfers heat to the heat pipes by aluminum fins. The liquid inside of the heat pipe changes into vapour which rises to the condenser. The heat ehn passes through the heat exchanger and the vapour becomes liquid returning to the base of the heat pipe. The het conducts to the heat transfer liquid ( anti-freezing liquid or water ) via a copper pipe. This transference of heat into the liquid creates a continuous circulation as long as the collecto is heated by the sun. 6. Collector installation 6.1 Installation Direction of collector The Collector should be installed to face the equator.to install the collector in the correct direction with right angle ensures the heat output of the collector. And a deviation of 10 is acceptable. 6.2 Installation Angle of Collector It is recommended to install the collector at an angle that corresponds to the latitude of the location. Installing at an angle less than 30 is not recommended. Because the heat pipe works best between the degree of 30-70. According to this an angle of latitude +/- 10 is acceptable. An angle beyond this scope will decrease the output of the heat. The following is the pictures for installation.

www.ejaisolar.com ZHEJIANG EJAI SOLAR TECHNOLOGY CO.,LTD. 6 6.3 Installation Steps: STEP1: Install the tailed support on the tailed track and then screw off the cap from the tailed support. STEP2: Put the Anti-dust rubber ring on thevacuum tube (lubricate the vacuum tube by mild dish washing liquid or water would be much easier when put the Anti-dust rubber ring on the vacuum tube). Coat the condenser end with heat paste grase. STEP3: Insert the vacuum tube into the tailed support. Please be careful and do not let the vacuum tube on the ground otherwise it might be broken. STEP4: Insert the vacuum tube into the manifold. STEP5: Screw the jacket on the tailed support.

www.ejaisolar.com ZHEJIANG EJAI SOLAR TECHNOLOGY CO.,LTD. 7 7. Circuit Installation Illustration

www.ejaisolar.com ZHEJIANG EJAI SOLAR TECHNOLOGY CO.,LTD. 8 8. Liquid filling illustration Medium Liquid = 56% Pure water + 44%Original Anti-freezing Liquid Pure water :56% Diving Pump Using diving pump filling medium liquid Original anti-freezing liquid:44% + 56% pure water

www.ejaisolar.com ZHEJIANG EJAI SOLAR TECHNOLOGY CO.,LTD. 9 8.1 Liquid filling Steps : STEP1: Open V1, V3, close V2 and then start the diving pump to filling the medium liquid from V1 until the liquid flow out from V2. Let the circulation last for 1 minute until exhaust all the air from the pipeline. STEP2: Close V3 and Open V2 STEP3: Continue to filling the medium liquid from V1 until the pressure gauge shows the pressure to 2 bars or 3 bars and then close V1 and take off the diving pump. STEP4: Starting the system check the flowing meter (V5) to see if there is any air inside the pipeline. If there is air inside the pipeline then loosen (for 1-2 circles) the switch (located in the middle of the pump) in anti-clockwise direction. After all the air in the pipeline is exhausted tight the switch. 9. Illustration for the full system

www.ejaisolar.com ZHEJIANG EJAI SOLAR TECHNOLOGY CO.,LTD. 10 10. Water tank Location: The water storage tank should be placed as close as possible to the collector to avoid long pipe connections (considering the heat loss through the pipe). 11 Insulation of the pipe The pipes running to and from the collector are recommended to be heavily insulated. And regular checking of this insulation material (foam or other related material) is necessary. Here we recommended to use UV stabilized foam (or metallic wrap) as insulated material. The following is an example of the insulated pipe by foam.