TRV-2, TRV-2S. Thermostatic radiator valves With presetting

Similar documents
TBV-CM. Combined control & balancing valves for small terminal units For modulating control

TBV-CM. Combined control & balancing valves for small terminal units For modulating control NPT threads

TA-COMPACT-P. Combined control & balancing valves for small terminal units Pressure independent balancing and control valve (PIBCV)

STAP. Differential pressure controller DN 15-50

TA-Modulator. Combined control & balancing valves for small terminal units Pressure independent balancing and control valve for modulating control

STAD. Balancing valves DN 15-50

STAP. Differential pressure controllers DN , ANSI flanges

Floor heating. Floor heating manifolds Distributors

STAD-D. Balancing valves Balancing valve for domestic water systems, DN Balancing valves

STAP. Differential pressure controller DN

STAD-C. Balancing valve ENGINEERING ADVANTAGE

STAG. Balancing valves Balancing valve with grooved ends DN

STA. Double regulating valves DN 15-50

STAP. Differential pressure controllers DN , ANSI fl anges

TA-FUSION-P. Combined control & balancing valves Pressure independent combined balancing and control valves with independent EQM characteristics

STAD. Balancing valves DN (MD60, MD61, MD62)

STAD-C. Balancing valves DN 15-50

STA. Double regulating valves DN 15-50

TA-FUSION-P. NPT threads / ANSI flanges

TA-H.U.B. Centralised balancing and control ENGINEERING ADVANTAGE

Technote. Frese PVS - Dynamic Pressure and Flow Regulation Valve. Application. Features. Benefits.

Dynamic Valve Type RA-DV Pressure Independent Radiator Valve

Chrome plated radiator valves type RA-NCX and lockshield valves type RLV-CX

V5001P. Kombi-Auto Differential Pressure Control Valve. Product specification sheet

Differential pressure controller (PN 25) AVP - return and flow mounting, adjustable setting

Automatic balancing valves ASV

HERZ-Motorised flow controler

Presetting Valve Type RA-N with Flange Connection

Technote. Frese PV-SIGMA Compact Dynamic Pressure and Flow Regulation. Description. Application. Operation. Features. Benefits.

Differential pressure and flow controller (PN 16) AVPQ - return mounting, adjustable setting

STAD BALANCING VALVES

RA-N radiator valves with integrated presetting and self-sealing tailpiece

Automatic balancing valves

Versions. Benefits. Balancing DN15-32 DN40 DN50 DN15, DN20, DN25, DN32, DN40, DN50. Dimensions

Automatic balancing valves ASV

differential pressure regulating valve - threaded

Differential Pressure Control Valve. Passim

AVP-F. p setting range (bar) Code No. 003H6200

Pressure Reducing Valve DMV 755

Ballorex Dynamic Description. Versions. Benefits. Balancing

Differential pressure controller with flow limitation (PN 16, 25, 40) AFPB / VFQ 2(1) AFPB-F / VFQ 2(1)

2-port and 3-port valves PN 16

Differential pressure controller (PN 16) AHP - return mounting, adjustable setting

Radiator valves VDN2.. VEN2.. VUN2..

KTM 50 (DN ) Installation, maintenance and operating instructions

Automatic Balancing Valve Pressure difference controller with integrated flow limiter AB-PM DN

CALEFFI. Ball zone valves. series /03 GB

2-port seat valves PN25 with externally threaded connections

MZX. Three-Port Seat Valves SPECIFICIATIONS AND GUIDE TO SELECTION

Pressure reduction controller (PN 16, 25, 40)

Differential pressure control and flow limiter AVPB/AVPB-F, PN 16

Upgradable balancing valves USV

Overview of types. T5-R B2/R B2 en v Subject to changes 1 / 4. k vs (Sequence 2)

Technote. Frese ALPHA cartridges. Application. Features. Benefits.

Overview of types. Technical data. Safety notes

Pressure independent control valve (PICV) FLOWMATIC

Radiator thermostats type RA2000, valve bodies type RA-FN (series D) and RA-G

Differential pressure controller (PN 16) AVPL - return mounting, adjustable setting

Differential pressure controller (PN 16) AVPL return mounting, adjustable setting

Radiator thermostats type RA2000, valve bodies type RA-FN (series D) and RA-G

Radiator valves VDN1.. VEN1..

AVPQ/AVPQ-F, PN 16. Application

3-port seat valves with externally threaded connection, PN 16

Products no longer available

Technical data sheet. Type overview. Technical data. Safety notes. T5-R2.. Open-close en v Subject to changes 1 / 3

Pressure Relief Valve DHV 718

Aquapresso. Pressure stabilisation for potable water Pressure stabilisation for potable water

Two-port seat valves

PCMTV Pressure independent control valves, DN20-DN32 with integrated flow limiter for thermal emitters and differential pressure regulator

V5012C Kombi-DP Diaphragm Unit RETROFIT AUTOMATIC DP CONTROLLER

Hycocon. Technical information. Das Qualitätsmanagementsystem von Oventrop ist gemäß DIN-EN-ISO 9001 zertifiziert.

Pressure balanced valves (PN 25)

Pressure independent balancing and control valve AB-QM DN

Seated valves VRB 3, VRG 3

PCTV/PCMTV/PCTVS15-25

Pressure Independent Control Series

2-port and 3-port seat valves, PN16

Type overview. R B2 en-gb subject to changes 1

PVM 15-50, differential pressure valves

Cim 787 Variable orifice balancing valve

Product Sheet Pre-Fabricated Flushing Bypass Assembly for Terminal Applications Mini-Flush 40

DIFFERENTIAL PRESSURE REGULATING VALVE

Automatic balancing valves ASV

By-pass valves Series 466 Thermatic - Series USVR

DS MZ, MZF, MJF THREE-PORT SEAT VALVES

VFPIP/VFPIM/VFPI 15-25

Rp [ ] Sv min. [ ] C215QP-B 15 1/ C215QP-D 15 1/ C220QP-F 20 3/ [ ]

Overview of types. Technical data

Three-port valves. Special versions with special stem sealing gland for: High temperature hot water C Thermo oils

Products no longer available

BTV. Internally threaded 2-way control valve. Flow characteristics. Function

STA-F Description. STA-F Prefab insulation Measuring nipples

USER MANUAL Version: 1/2017

Some system examples

Pressure Relief Valve DHV 718

Balancing Valves. Applications/ Features: Ordering Information: Accessories:

STAD Series. Balancing and control valves. Technical Data Sheet. WattsIndustries.com

Multifunctional Thermostatic Circulation Valve MTCV - Lead free brass

Mounting and Operating Instructions EB 8546 EN. Supply Pressure Regulator Type Fig. 1 Supply pressure regulators

TECHNICAL CATALOGUE PRESSURE REDUCING VALVES EUROPRESS

Transcription:

TRV-2, TRV-2S Thermostatic radiator valves With presetting

IMI EIMEIER / Thermostatic heads and Radiator valves / TRV-2, TRV-2S TRV-2, TRV-2S Thermostatic radiator valve primary for radiators in heating systems and secondary for small cooling terminals. Key features > > Stepless presetting Accurate balancing. > > Max Δp 30 kpa Better comfort. > > ouble O-rings Trouble free operation. Technical description Applications: eating and cooling systems Function: Control Stepless presetting Shut-off imensions: N 10-20 Pressure class: PN 10 Max. differential pressure: Maximum differential pressure to ensure that the valve does not open against a closed thermostat: 100 kpa. Temperature: Max. working temperature: 120 C Min. working temperature: -10 C Materials: Valve body: Straight and angle of AMETA. Reversed angle of brass. O-rings: EPM rubber Valve disc: EPM rubber Return spring: Stainless steel Valve insert: Brass, PPS (polyphenylsulphide) Spindle: Stainless steel AMETA is the dezincification resistant alloy of IMI ydronic Engineering. Surface treatment: Valve body and fittings are nickel-plated Marking: TA, country code, flow direction arrow, size and KEYMARK symbol. TRV-2: White protection cap. TRV-2S: Red protection cap. The locking nut at the valve insert is marked in red. Standards: KEYMARK certified and tested according to EN 215. 026 Connection to thermostatic head: M30x1.5 2

Operating instruction The valve is supplied with a protective wheel. The protective wheel can easily be replaced by a handwheel, thermostatic head or an actuator. If the protective wheel is used to isolate when dismounting the radiator, the outlet must be plugged or capped. Attention! TRV-2/TRV-2S requires clean system water to work properly without disturbance because of clogging. Noise The following conditions must be fulfilled in order to avoid noise in the heating system: The maximum recommended pressure drop in order to aviod noise: 30 kpa = 0,3 bar. Flows correctly balanced The water in the system must have been de-aerated Circulation pumps which do not give too high differential pressure (alternative use a differential pressure controller, e.g. STAP). Setting The valve has stepless pre-setting which can be adjusted by the pre-setting tool. The valve is delivered with the pre-setting of 6, i.e. fully open valve. 1. Remove the protective wheel. 2. Set the required value using the pre-setting tool (Article No 50 198-004). 3. Refit the protective wheel (alternatively the thermostat head or the handwheel). 3

IMI EIMEIER / Thermostatic heads and Radiator valves / TRV-2, TRV-2S iagram TRV-2 Straight and angle (KvΔT2K) kpa 50 40 1.5 2.5 3.5 4.5 5.5 1 2 3 4 5 6 30 20 15 10 5 4 3 2 1.5 1 5 10 20 50 100 200 500 1000 l/h Pre-setting value 1 1.5 2 2.5 3 3.5 4 4.5 5 5.5 6 KvΔT2K* 0,047 0,073 0,098 0,130 0,161 0,198 0,234 0,299 0,364 0,416 0,468 Fully open valve disc** 0,054 0,079 0,104 0,139 0,174 0,211 0,247 0,353 0,459 0,630 0,800*** iagram TRV-2 Reversed angle (KvΔT2K) kpa 50 40 1.5 2.5 3.5 4.5 5.5 1 2 3 4 5 6 30 20 15 10 5 4 3 2 1.5 1 5 10 20 50 100 200 500 1000 l/h Pre-setting value 1 1.5 2 2.5 3 3.5 4 4.5 5 5.5 6 KvΔT2K* 0,063 0,089 0,095 0,120 0,152 0,171 0,206 0,281 0,348 0,421 0,462 Fully open valve disc** 0,063 0,089 0,095 0,123 0,158 0,180 0,221 0,323 0,430 0,626 0,727*** *) The values are valid when used together with thermostic head TRV 300. **) The values are valid for on/off regulation with, for example, thermo actuator EMO T. ***) Fully open valve. 4

iagram TRV-2S ow flow (KvΔT2K) kpa 50 40 1.5 2.5 3.5 4.5 5.5 1 2 3 4 5 6 30 20 15 10 5 4 3 2 1.5 1 5 10 20 50 100 200 500 1000 l/h Pre-setting value 1 1.5 2 2.5 3 3.5 4 4.5 5 5.5 6 KvΔT2K* 0,017 0,022 0,041 0,047 0,063 0,075 0,111 0,142 0,177 0,228 0,316 Fully open valve disc** 0,017 0,022 0,041 0,047 0,063 0,078 0,114 0,150 0,187 0,240 0,350*** *) The values are valid when used together with thermostic head TRV 300. **) The values are valid for on/off regulation with, for example, thermo actuator EMO T. ***) Fully open valve. 5

IMI EIMEIER / Thermostatic heads and Radiator valves / TRV-2, TRV-2S Excluding radiator union Straight N 1 2* KvΔT2K EAN Article No 10 G3/8 M22x1,5 50 36 107 0,047-0,468 7318793757500 50 861-610 15 G1/2 M26x1,5 58 38 109 0,047-0,468 7318793757609 50 861-615 20 G3/4 M34x1,5 68 38 109 0,047-0,468 7318793757708 50 861-620 N 1 2* KvΔT2K EAN Article No 10 G3/8 M22x1,5 50 36 107 0,017-0,316 7318793788009 50 861-010 15 G1/2 M26x1,5 58 38 109 0,017-0,316 7318793788108 50 861-015 20 G3/4 M34x1,5 68 38 109 0,017-0,316 7318793788207 50 861-020 Angle N 1 2* KvΔT2K EAN Article No 10 G3/8 M22x1,5 23 20 36 107 0,047-0,468 7318793758309 50 863-610 15 G1/2 M26x1,5 26 24 38 109 0,047-0,468 7318793758408 50 863-615 20 G3/4 M34x1,5 31 28 36 107 0,047-0,468 7318793758507 50 863-620 N 1 2* KvΔT2K EAN Article No 10 G3/8 M22x1,5 23 20 36 107 0,017-0,316 7318793946805 50 863-010 15 G1/2 M26x1,5 26 24 38 109 0,017-0,316 7318793946904 50 863-015 20 G3/4 M34x1,5 31 28 36 107 0,017-0,316 7318793947000 50 863-020 Reversed angle N 1 2* KvΔT2K EAN Article No 10 G3/8 M22x1,5 23 21 47 119 0,063-0,462 7318793759009 50 864-610 15 G1/2 M26x1,5 26 25 47 119 0,063-0,462 7318793759108 50 864-615 N 1 2* KvΔT2K EAN Article No 10 G3/8 M22x1,5 23 21 47 119 0,017-0,316 7318793787606 50 864-010 15 G1/2 M26x1,5 26 25 47 119 0,017-0,316 7318793787705 50 864-015 Angle For replacement of radiator valve in manifold assemblies. 1, 2 N 1 2* KvΔT2K EAN Article No 10 G3/8 M22x1,5 27 46,5 37 108 0,017-0,316 7318793947703 50 864-210 *) Valve with fitted thermostat. Kv = m 3 /h at Δp = 1 bar. KvΔT2K = The values are valid when used together with thermostatic head TRV 300. 6 All valves can be connected to smooth pipes by means of the KOMBI compression coupling - See catalogue leaflet KOMBI.

Including radiator union d Straight N d 1 2* KvΔT2K EAN Article No 10 R3/8 G3/8 M22x1,5 75 36 107 0,047-0,468 7318793757807 50 861-110 15 R1/2 G1/2 M26x1,5 88 38 109 0,047-0,468 7318793757906 50 861-115 20 R3/4 G3/4 M34x1,5 102 38 109 0,047-0,468 7318793758002 50 861-120 N d 1 2* KvΔT2K EAN Article No 10 R3/8 G3/8 M22x1,5 75 36 107 0,017-0,316 7318793788306 50 861-510 15 R1/2 G1/2 M26x1,5 88 38 109 0,017-0,316 7318793788405 50 861-515 Straight d N d 1 2* KvΔT2K EAN Article No 10 R3/8 G3/8 M22x1,5 93 46 36 107 0,047-0,468 7318793758101 50 862-110 15 R1/2 G1/2 M26x1,5 106 52 38 109 0,047-0,468 7318793758200 50 862-115 d Angle N d 1 2* KvΔT2K EAN Article No 10 R3/8 G3/8 M22x1,5 48 20 36 107 0,047-0,468 7318793758606 50 863-110 15 R1/2 G1/2 M26x1,5 56 24 38 109 0,047-0,468 7318793758705 50 863-115 20 R3/4 G3/4 M34x1,5 65 28 36 107 0,047-0,468 7318793758804 50 863-120 N d 1 2* KvΔT2K EAN Article No 10 R3/8 G3/8 M22x1,5 48 20 36 107 0,017-0,316 7318793947109 50 863-510 15 R1/2 G1/2 M26x1,5 56 24 38 109 0,017-0,316 7318793947208 50 863-515 20 R3/4 G3/4 M34x1,5 65 28 36 107 0,017-0,316 7318793947307 50 863-520 d Reversed angle N d 1 2* KvΔT2K EAN Article No 10 R3/8 G3/8 M22x1,5 48 21 47 119 0,063-0,462 7318793758903 50 864-110 15 R1/2 G1/2 M26x1,5 56 25 47 119 0,063-0,462 7318793759603 50 864-115 N d 1 2* KvΔT2K EAN Article No 10 R3/8 G3/8 M22x1,5 48 21 47 119 0,017-0,316 7318793787804 50 864-510 15 R1/2 G1/2 M26x1,5 56 25 47 119 0,017-0,316 7318793787903 50 864-515 *) Valve with fitted thermostat. Kv = m 3 /h at Δp = 1 bar. KvΔT2K = The values are valid when used together with thermostatic head TRV 300. All valves can be connected to smooth pipes by means of the KOMBI compression coupling - See catalogue leaflet KOMBI. 7

IMI EIMEIER / Thermostatic heads and Radiator valves / TRV-2, TRV-2S Accessories Pre-setting tool EAN Article No 7318793748102 50 198-004 Servicing tool TRV-2, TRV-2S When changing of valve insert during operation EAN Article No 4024052298914 9721-00.000 Spare parts The valve insert can be exchanged during operation - please contact IMI ydronic Engineering for more information. The products, texts, photographs, graphics and diagrams in this document may be subject to alteration by IMI ydronic Engineering without prior notice or reasons being given. For the most up to date information about our products and specifications, please visit www.imi-hydronic.com. 1-5-5 TRV-2, TRV-2S 09.2014