VERTICAL BLADDER TANK

Similar documents
HORIZONTAL BLADDER TANK

Vertical and Horizontal Bladder Tanks

Vertical Bladder Tanks

Horizontal Bladder Tanks

Model MTB-ASME Vertical Bladder Tanks

Model MTB-ASME Vertical Bladder Tanks

Model MTB-ASME Horizontal Bladder Tanks

SABERINDO PACIF SABERINDO PACIFIC CIFIC SABERINDO PA. A Tyco International Company

LINE PROPORTIONERS LP NPR260 Approvals: UL, ULC

FOAM TANK (1/2) DATA SHEET

FOAM TANK (1/2) DATA SHEET

SEMI FIXED/PORTABLE LINE PROPORTIONERS SLP NPR270

TECHNICAL DATA OBSOLETE

TECHNICAL DATA. Low-Flow Foam Preaction System with Hydraulically Actuated Concentrate Control Valve.

TECHNICAL DATA. than the water inlet pressure to the concentrate

FM Approved - Automatic Water Control Valve as standard deluge valve. No formal approval available for coating. Foam Concentrate

BLADDER TANK PROPORTIONING SYSTEM PRE-PIPED

Bladder Tank Installation & System Design Information

DESIGN DATA OBSOLETE. C. Inspections - It is imperative that the system be inspected and tested on a regular basis. See Inspection

FM Approved - Automatic Water Control Valve as standard deluge valve. No formal approval available for coating. Foam Concentrate

Pipe Thread Connection 1/2 inch NPT. Friction Loss Refer to Figure 3

OBSOLETE. Wet pipe low flow manifold system

Wet pipe low flow foam/water system

DESIGN DATA A WET PIPE BLADDER TANK FOAM/WATER SYSTEM WITH HYDRAULICALLY ACTUATED DELUGE CONCENTRATE CONTROL VALVE

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B

TECHNICAL DATA Q= C. Table 1 - Specifications

TECHNICAL DATA OBSOLETE

TECHNICAL DATA. Trimpac 251a. Spetember 16, 2013

TECHNICAL DATA. Trimpac 244a. September 16, 2013

TECHNICAL DATA. Page 1 of 12

TECHNICAL DATA. Trimpac 257a. September 16, 2013

TECHNICAL DATA CAUTION

BALANCED PRESSURE PROPORTIONERS

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Trimpac 256a. October 31, 2013

ECS Protector Nitrogen Inerting Vent (PAV-WN)

TECHNICAL DATA. Pressure Regulation 531a. April 24, 2009

OBSOLETE DESIGN DATA. Foam 301a. February 9, 1998

Model B-1 Pipe Line Strainer 3, 4, 6 & 8 Inch (DN80, DN100, DN150 & DN200) 175 psi (12,1 bar) General Description. Technical Data

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

TECHNICAL DATA PILOT PRESSURE REGULATED DELUGE SYSTEM CONTROLLED BY PNEUMATIC RELEASE. 1. DESCRIPTION (Refer to Figures 1, 2 or 3.

TECHNICAL DATA. Page 1 of 8. model f /2 (dn40) & 2 (dn50)

TECHNICAL DATA DELUGE VALVE, MODEL F-1 STRAIGHT THROUGH STYLE

Anti-flood device Model B-1

End Connection. Thread x Thread N/A N/A N/A N/A Flange x Flange N/A

TECHNICAL DATA. Table 1 - Specifications

TECHNICAL DATA. Q= Cv S

AIR FOAM CHAMBER DATA SHEET

TECHNICAL DATA. the Viking Pilot Pressure Regulating Valve 1 Model A-1 Speed Control Assembly: OBSOLETE. the Viking Speed Control Assembly 1

TECHNICAL DATA ANTI-FLOOD DEVICE MODEL B-1 1. DESCRIPTION

PTF4 Pivotrol Pump (patented) version Dual Mechanism - Pressure Powered Pump

ABRASIVE REGULATOR II

Features. Model DDX-LP Dry Pipe Valve System 4 (100mm), 6 (150mm) & 165mm Sizes

Model DDX-LP Dry Pipe Valve System 8 (200mm) Features. Differential latching clapper-type, lighweight, dependable construction.

Flow Material Length. Weight GPM LPM. Style 3095

TECHNICAL DATA PILOT PRESSURE REGULATED DELUGE SYSTEM CONTROLLED BY ELECTRIC RELEASE 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3.

TECHNICAL DATA CAUTION

MEDICAL EQUIPMENT CATALOG

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S

MUELLER. A Wall Type. Indicator Post. Reliable Connections. General Information 2. Technical Data/ Dimensions 3. Installation 4-5.

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Inlet Type Outlet Type OBSOLETE. 4. TECHNICAL DATA Approvals:

ABRASIVE REGULATOR II

FIK In-Tank Filters FIK. Max Flow: 170 gpm (643 lpm) Working Pressures to: Rated Static Burst to: Flow Range to:

WHEATLEY WHEATLEY SERIES 500 SWING CHECK VALVE. Installation, Operation and Maintenance Manual

TECHNICAL DATA. Q = C v P S

Inflatable Packer Single & Double. Single & Double Packer Dimension. Wireline Packer. Water Testing Packer (WTP) Packer

Data Sheet Issue A

ANSUL. Part No

TECHNICAL DATA. Q = C v P S

1 Exam Prep. Tabs and Highlights

Installation, Operation and Maintenance Manual for Back Pressure Regulator

Tank Blanketing Pressure Regulators RHPS Series

Operating Instructions Models and Hydrostatic Test Pumps

CAST IRON VALVES FLOAT VALVE

TECHNICAL DATA SINGLE INTERLOCKED PREACTION SYSTEM WITH PNEUMATIC RELEASE

Type S301 & S302 Gas Regulators INTRODUCTION INSTALLATION. Scope of Manual. Description. Specifications. Type S301 and S302. Instruction Manual

TECHNICAL DATA OBSOLETE

WELL COMPLETION & PROTECTION. www. .com MINERAL EXPLORATION ENVIRONMENTAL GEOTECHNICAL GEOTHERMAL ROTARY SONIC HDD

Full Range Pressure Compensating Variable Flow Control

SUBMITTAL NOTES PROJECT: Ross Model 50RWR-A Pilot Operated Surge Relief Valve with Hydraulic Anticipation. Size: inch / mm

Features. Model EX Low Pressure Dry Pipe Valve System 2 (DN50), 2½ (DN65), 3 (DN80), 76 mm, 4 (DN100 ), 6 (DN150), 165 mm & 8 (DN200)

V43 Pressure Actuated Water Regulating Valve

Bermad Pressure Reducing. Model: 42T

WaterSource Heat Pump Hose Kit Performance Specification-Summary

Operating Instructions Model and Hydrostatic Test Pump

ABRASIVE SYSTEM ABRASIVE REGULATOR II 800# BULK ABRASIVE DELIVERY POT Abrasive Regulator II and 800# Pot Manual

BERMAD Waterworks. Level Control Valve with Altitude Pilot. 700 Series. Model X. Features and Benefits. Major Additional Features

TECHNICAL ACCESSORIES

Operating Instructions Models 36200, , 46200, Hydrostatic Test Pumps

North American Orifice Metering System

Pressure and/or Temperature Pilot Operated Steam Regulators Series 2000

Worldwide Contacts. General Description

VIKING OBSOLETE CONCENTRATE CONTROL SYSTEM OPERATING, MAINTENANCE, AND FILLING MANUAL. Vertical And Horizontal Bladder Tanks

CONCENTRATE CONTROL SYSTEM

D05 Pressure Regulating Valves

Features. Model DDX-LP Dry Pipe Valve System 2 (50 mm), 2½ (65 mm), 3 (80 mm), 76 mm, 4 (100 mm), 6 (150 mm), 165 mm & 8 (200mm) Listings & Approvals

Model 4000 Pressure Controller

Transcription:

Balanced Pressure Proportioning System Reliable Foam System Requiring Only Water Power Perfect For Tight Spaces UL Listed, ASME, National Board Registered Bladder-UL162 Approved, High Tensile Pressure Formed Seams Interior Strainers And Flow Path Devices Supplied With All Valves, Piping And Equipment Necessary For Operation Custom Designs Available Description Features vent to the water drain connection, preventing bladder obstruction at The Bladder Tank Proportioning Compatible with all foam these openings. System is a balanced pressure concentrates proportioning system, requiring no Requires less floor space than The ratio controller (RCF) shall be a external power other than an adequate flanged style for mounting in Schedule horizontal tanks water supply. A bladder tank, with an 40 pipe between two 150# flat or raised Bottom foam concentrate discharge flanges of the same nominal size as appropriate proportioner(s), injects keeps feed piping full, eliminating air the RCF. The RCF shall be cast bronze foam concentrate into the water pockets and preventing corrosion with stainless steel hardware and shall supply of a fire protection system and Permanently welded lifting lugs for be rated for a working pressure of automatically proportions over a wide safe tank movement and positioning 250 psi (17 bar). The ratio controller range of flows and pressures. shall incorporate a recovery section Applications The Bladder Tank Proportioning System to minimize the pressure loss through the proportioner and reduce the employs water to pressurize the Frequently used in aircraft hangars, straight pipe length required after the bladder and force foam concentrate to loading racks, sprinkler systems, and controller. A ¼ (6.35 mm) female NPT the ratio controller. The water supply offshore platforms. port for sensing water pressure at the simultaneously feeds the ratio controller Technical Specifications inlet to the ratio controller water orifice and the bladder tank. As water flows shall be incorporated into the casting. through the ratio controller the level of The National Foam bladder tank system Each ratio controller shall automatically pressure reduction increases, thereby shall be a complete self-contained proportion over the range indicated on affecting a corresponding pressure drop proportioning system consisting of flow range chart without any manual across the foam concentrate metering a bladder tank, ratio controller, and adjustment. The foam concentrate orifice. The corresponding pressure assembled piping. The bladder tank inlet shall contain a foam concentrate shall be an ASME code welded carbon drop results in foam concentrate flow metering orifice with field adjustment steel pressure vessel with a working that is proportionate to the water flow feature to allow user to fine tune pressure of 175 psi (12 bar). The proportioning. through the ratio controller. As both tank shall be supplied in the vertical the water and foam concentrate flow configuration and shall be mounted The ratio controller shall be pre-piped into a common reduced pressure area, on full skirt securely welded to tank to the bladder tank. All external piping it is necessary only to maintain identical shell, complete with four mounting shall be Schedule 40, and shall be brass water and foam concentrate pressures clips. A flexible, thermoplastic for foam concentrate and carbon steel at the respective inlets of the ratio vulcanized rubber internal bladder for water. Brass or bronze ball valves of controller. separates the foam concentrate from the locking handle type, in accordance the incoming water. The bladder with NFPA requirements for valve During operation, the water outside shall be manufactured with single supervision, shall be supplied, and shall the bladder gradually displaces the piece nozzles and all seams shall be be complete with identification labels foam concentrate inside causing the temperature/pressure high tensile on the handles. A ball check valve shall bladder to collapse until the supply is strength using no adhesives. The tank be installed in the foam concentrate exhausted. The bladder tank may then shall have perforated PVC schedule line. Tank shall include all necessary be isolated and the system allowed to 0 center discharge piping, located drain and vent valves, concentrate discharge water only. Since the bladder within the bladder, to ensure that fill piping, fill cup, and tank content/ tank is pressurized, the bladder cannot foam concentrate flows to the bottom identification labels. External surfaces be refilled during operation. discharge. A section of 1-inch I.D. rubber of tank and piping shall be coated with hose installed between the bladder and red high solids acrylic polyurethane tank shell, shall extend from the water finish. 06/16 (Rev Q) Page 1 of 6

Approvals and Listings Underwriters Laboratories, Inc. (UL Listed) Technical Information Materials of Construction: Tank: Carbon steel, ASME code Bladder: Welded seam thermoplastic Internal Piping: Perforated PVC, Sch. 0 External Piping: Water Side: Carbon Steel, Sch. 40, Screwed Fm. Conc. Side: Brass, Sch. 40, Screwed Valves: Ball valve with locking handle, bronze body, and brass or chrome plated brass ball Fill Funnel: Polyethylene, 7½ diameter cup x 1 male NPT spout Ratio Controller: Cast Bronze (5-5-5-5), ASTM-B-54 alloy #3600 Exterior Finish: Red high solids acrylic polyurethane (NF Spec AS1-06-030) Working Pressure: 175 psi (12 bar) Options Sight gauge: 1½ (3 mm) O.D. polycarbonate with bronze ball shutoff valve Higher tank working pressures Coal tar epoxy internal coating Special finishes Pressure relief valve Type 304 or 316 stainless steel piping, screwed or welded Fill kit Automatic concentrate valve. Typically NF WPBV, also available as electrically or pneumatically actuated valve. Alternate style and multiple ratio controllers Reversed flow direction CONTRACTOR P.O.C.- SEE TABLE 4 FOR RC CONNECTION SIZE AND TYPE WATER FEED 2 4 "A" RATIO CONTROLLER CONTRACTOR P.O.C. - SEE TABLE 4 FOR RC CONNECTION SIZE AND TYPE CHECK VALVE "B" 5 INSTALLATION INSTRUCTION LABEL CAUTION LABEL LIFTING LUG 7-3/4 FILL FUNNEL TO BE SCREWED INTO VALVE #5 SEE NOTE #9 "H" "J" -3/4 "K" CONC. LEVEL CHECK LABEL "G" "C" OPERATING INSTRUCTIONS U.L. AND F.M. LABELS 3" THRU " RC ASSEMBLY 6 A 90 TYP. 9 A 7 1A 1 "F" C B B C 1-3/4 5-1/ 11-7/ 2" RC ASSEMBLY 9 Ø "E" HOLE (TYP. 4) 45 TYP. Ø "D" BOLT CIRCLE DETAIL A - A FLOOR ANCHORING DETAIL SIGHT GLASS (OPTIONAL) 7 9 SIGHT GLASS (OPTIONAL) 7 TABLE 1 - RC DIMENSIONS Assembly w/spool Q R S 3" RC 19 4 4-1/2 4" RC 25 4-1/4 7 6" RC 27 5-1/4 9-11/16 " RC 31 7 10 DETAIL B - B DETAIL C - C Page 2 of 6 06/16 (Rev Q)

TABLE 2 - VALVE DESCRIPTION Valve Normal Position No. Description Manual System Auto. System 1 Concentrate Supply Closed Open 1A Auto. Concentrate Supply (Optional) --- Closed 2 Water Pressure Supply Open Open 4 Tank Water Vent Closed Closed 5 Concentrate Vent/Fill Closed Closed 6 Water Drain/Fill Closed Closed 7 Concentrate Drain/Fill Closed Closed Sight Glass (Optional) Closed Closed 9 Sight Glass Supply (Optional) Open Open TABLE 3 - SUGGESTED RATIO CONTROLLER SIZES FOR SYSTEM FLOWS Ratio Controller Size in. (mm) Standard Flow Range gpm (lpm) Special Flow Range with AR-AFFF Foam Concentrate gpm (lpm) 2 (51) 30-10 (114-61) 60-10 (227-61) 3 (76) 70-450 (265-1703) 170-450 (644-1703) 4 (102) 150-1200 (56-4542) 320-1200 (1211-4542) 6 (152) 300-2500 (1136-9463) 700-2500 (2650-9463) (203) 50-5000 (321-1925) 1400-5000 (5300-1927) Water & Concentrate Line Sizes in. (mm) Line Sizes to be Determined by NF at System Design. Ratio Controller Connections in. (mm) Inlet Outlet 2 (51) NPT (F) 3 (76) 4 (102) 6 (152) (203) 2 (51) NPT (F) 3 (76) 4 (102) 6 (152) (203) NOTES: 1. All dimensions are approximate and may vary slightly. 2. Weights listed apply to empty tanks. 3. All tank and valve openings will be plugged for shipping. 4. Optional sight glass assembly includes: Polycarbonate sight glass tube, 1½ (3) O.D. open to atmosphere (vented cap) Ball shutoff valve Split pipe clamp w/ threaded rod 5. Fill funnel and optional sight glass tube will be packed and shipped separately. 6. Optional sight glass level check cannot be performed with alcohol type AFFF concentrates. Refer to the operating and maintenance manual for further instructions. 7. Contents label will be supplied to customer by NF with foam concentrate order and applied by customer.. When designing a building to house bladder tanks, provisions must be to allow for the removal of the internal piping and bladder. These items are the full height of tank. 9. Concentrate vent valve #5 will also be used to top off the concentrate level. A fill funnel will be provided with each tank for this purpose. 10. For non-standard or special tanks, refer to the tank s specific outline assembly drawing for details. 11. For tanks exceeding reasonable shipping crate sizes, piping will be supplied disassembled using grooved couplings for easy assembly at installation site. 06/16 (Rev Q) Page 3 of 6

TABLE 2 - CAPACITY AND DIMENSIONS CHART Capacity gal. (liters) A B C D E F G Empty Weight lb (kg) 25 (95) 20 (50) 22 (559) 46 (116) 22-3/4 (57) 9/16 (14) 4 (102) 49 (1245) 350 (159) 36 (136) 24 (610) 24 (610) 46 (116) 22-3/4 (57) 9/16 (14) 4 (102) 50 (1270) 420 (191) 50 (19) 24 (610) 24 (610) 46 (116) 22-3/4 (57) 9/16 (14) 4 (102) 5 (1473) 507 (230) 100 (379) 24 (610) 24 (610) 5 (2159) 22-3/4 (57) 9/16 (14) 4 (102) 7 (2210) 665 (302) 150 (56) 30 (762) 27 (66) 2 (1561) 27-3/4 (705) 9/16 (14) 4 (102) 6 (214) 20 (372) 200 (757) 30 (762) 27 (66) 100 (2540) 27-3/4 (705) 9/16 (14) 4 (102) 104 (2642) 957 (434) 300 (1136) 36 (914) 30 (762) 103 (2616) 32-3/4 (32) 9/16 (14) 4 (102) 10 (2743) 1301 (591) 400 (1514) 4 (1219) 36 (914) 3 (210) 41-1/2 (1054) 11/16 (17) 4 (102) 91 (2311) 1704 (773) 500 (192) 4 (1219) 36 (914) 97 (2464) 41-1/2 (1054) 11/16 (17) 4 (102) 105 (2667) 1760 (799) 600 (2271) 4 (1219) 36 (914) 112 (245) 41-1/2 (1054) 11/16 (17) 4 (102) 120 (304) 169 (4) 700 (2649) 4 (1219) 37-1/2 (953) 126 (3200) 41-1/2 (1054) 11/16 (17) 4 (102) 134 (3404) 2099 (953) 750 (239) 4 (1219) 37-1/2 (953) 134 (3404) 41-1/2 (1054) 11/16 (17) 4 (102) 142 (3607) 2200 (999) 00 (302) 60 (1524) 43-1/2 (1105) 102 (2591) 51-1/2 (130) 11/16 (17) (203) 113 (270) 2304 (1046) 900 (3407) 60 (1524) 43-1/2 (1105) 110 (2794) 51-1/2 (130) 11/16 (17) (203) 122 (3099) 2634 (1196) 1000 (375) 60 (1524) 43-1/2 (1105) 120 (304) 51-1/2 (130) 13/16 (21) (203) 132 (3353) 3030 (1375) 1100 (4164) 60 (1524) 43-1/2 (1105) 130 (3302) 51-1/2 (130) 13/16 (21) (203) 141 (351) 4123 (171) 1200 (4542) 60 (1524) 43-1/2 (1105) 140 (3556) 51-1/2 (130) 13/16 (21) (203) 150 (310) 3521 (159) 1300 (4921) 60 (1524) 43-1/2 (1105) 150 (310) 51-1/2 (130) 13/16 (21) (203) 160 (4064) 3640 (1652) 1400 (5300) 60 (1524) 43-1/2 (1105) 15 (4013) 51-1/2 (130) 13/16 (21) (203) 169 (4293) 3759 (1706) 1500 (567) 60 (1524) 43-1/2 (1105) 167 (4242) 51-1/2 (130) 13/16 (21) (203) 17 (4521) 310 (1729) 1600 (6057) 72 (129) 49-1/2 (1257) 134 (3404) 57-1/2 (1461) 13/16 (21) (203) 144 (365) 3900 (1770) 1700 (6435) 72 (129) 49-1/2 (1257) 140 (3556) 57-1/2 (1461) 13/16 (21) (203) 150 (310) 4125 (172) 100 (614) 72 (129) 49-1/2 (1257) 147 (3734) 57-1/2 (1461) 13/16 (21) (203) 157 (39) 4250 (1929) 1900 (7192) 72 (129) 49-1/2 (1257) 153 (36) 57-1/2 (1461) 13/16 (21) (203) 163 (4140) 4375 (196) 2000 (7571) 72 (129) 49-1/2 (1257) 160 (4064) 57-1/2 (1461) 13/16 (21) (203) 170 (431) 4500 (2043) 2100 (7949) 72 (129) 49-1/2 (1257) 166 (4216) 57-1/2 (1461) 13/16 (21) (203) 176 (4470) 4625 (2099) 2200 (32) 72 (129) 49-1/2 (1257) 173 (4394) 57-1/2 (1461) 13/16 (21) (203) 13 (464) 4750 (2156) 2300 (706) 72 (129) 49-1/2 (1257) 179 (4547) 57-1/2 (1461) 13/16 (21) (203) 19 (401) 475 (2213) 2400 (905) 72 (129) 49-1/2 (1257) 16 (4724) 57-1/2 (1461) 13/16 (21) (203) 196 (497) 5000 (2270) Page 4 of 6 06/16 (Rev Q)

ORDERING INFORMATION Part Number Approx. Approx. Shipping Package Dimensions Capacity (with or without Shipping Weight L W H gal. liters sight gauge) lb kg in. mm in. mm in. mm 25 95 Tanks with prepiped ratio 760 345 34 64 34 64 55 1397 36 136 controllers are custom to 770 350 36 914 36 914 56 1422 50 19 customer request. 00 363 36 914 36 914 64 1626 100 379 Please contact 950 431 93 2362 41 1041 50 1270 150 56 National Foam Inc. for 1095 497 92 2337 3 965 52 1321 200 757 part numbers and pricing. 1225 556 110 2794 3 965 52 1321 300 1136 2000 90 114 296 43 1092 57 144 400 1514 2200 999 97 2464 55 1397 69 1753 500 192 2350 1067 109 2769 55 1397 69 1753 600 2271 2500 1135 124 3150 55 1397 69 1753 700 2649 2650 1203 13 3505 55 1397 69 1753 750 239 200 1271 146 370 55 1397 69 1753 00 302 2900 1316 119 3023 67 1702 2 203 900 3407 3250 1475 12 3251 67 1702 2 203 1000 375 3600 1634 13 3505 67 1702 2 203 1100 4164 3950 1793 147 3734 67 1702 2 203 1200 4542 4300 1952 156 3962 67 1702 2 203 1300 4921 4650 2111 166 4216 67 1702 2 203 1400 5300 5000 2270 175 4445 67 1702 2 203 1500 567 5350 242 14 4674 67 1702 2 203 1600 6057 5550 2519 150 310 79 2007 94 23 1700 6435 5750 2610 156 3962 79 2007 94 23 100 614 5950 2701 163 4140 79 2007 94 23 1900 7192 6150 2791 169 4293 79 2007 94 23 2000 7571 6350 22 176 4470 79 2007 94 23 2100 7949 6550 2973 12 4623 79 2007 94 23 2200 32 6750 3064 19 401 79 2007 94 23 2300 706 6950 3155 195 4953 79 2007 94 23 2400 905 7150 3245 202 5131 79 2007 94 23 06/16 (Rev Q) Page 5 of 6

Page 6 of 6 06/16 (Rev Q) National Foam 350 East Union Street, West Chester, PA 1932, USA 24hr RED ALERT : 610-363-1400 Fax: 610-431-704 www.nationalfoam.com National Foam operates a continuous program of product development. The right is therefore reserved to modify any specification without prior notice and National Foam should be contacted to ensure that the current issues of all technical data sheets are used. National Foam