from Thames Cryogenics Ltd Total Cryogenic Solutions Cryogenic Cluster Day 22/09/2010

Similar documents
Series Environmental Chambers

Liquid Gas Cylinder (LGC)

MEDICAL EQUIPMENT CATALOG

Chem Bio Liquid Nitrogen Facility

Cryogenic Equipment. Accessories. Directors. Director Series Storage Vessels Specifications

INTRODUCTION. The Quantum Technology system has the following advantages:, as it does not need plastic gas-bags which are volume-consuming,

Microscopy Cryogenic WORKSTATION. Performance by Design

Series 58 SAFETY VALVES 312

Cryostream 800 Series

MODEL 269DF-LCF-LCF/WS FILLING SYSTEM

AUTOMATIC GAS MANIFOLDS

Delivery of Low Pressure Liquid Nitrogen

CVI Valve Line. Exceeds the industry s highest standards for reliability and performance

TANKTRONIC. STANDARD CONFIGURATION Single Tank. ADVANCED CONFIGURATION Multiple Tanks. Twin Tank (common valve) Twin Tank (separate valves) Vent box

OPERATION AND MAINTENANCE MANUAL

krones Sensometic VP and VPL The intelligent probe filler systems

The Protection of Silos From Over. Pressurisation During Filling

RC102 & RC110 Sample in Vacuum Continuous Flow Cryogenic Workstation Cryostats

Description Advanced Features Typical Applications

LPG DRIVER ATTENDED TRANSPORT LOADING

Vacuum Jacketed Piping Solutions

MANUAL GAS MANIFOLDS

Thanks for choosing EJAI SOLAR product

Summary of the MRA LPG Codes of Practice

Information Sheet. About this information sheet. Floor and wall loadings. Attachment of process module to floor. PlasmaPro Estrelas100

AutoDrill s OUTSTANDING FEATURES

Standard Operating and Maintenance Instructions for Pumping System Model PS-90

Work Horses of the Breathing Air Industry

Procedure for Operating Columbia (Nevis) LHe Electron Bubble Chamber Cryostat. Version 5.1

PMO 2.0 pee em ō too point ō

Major Design Features

Mobile Breathing Air Systems

ACV-10 Automatic Control Valve

OPERATION MANUAL NTF-15

Multiple Pressure Booster Systems With Variable Speed Controller Type BL

TECHNICAL SPECIFICATION. SPC-1 Stirling Process Cryogenerator

Nitrogen Generators. PMNG Commercial Series. Section 50 Bulletin A -20

TECHNICAL SPECIFICATION. SPC-4 Stirling Process Cryogenerator

English. Introduction. Safety Instructions. All Products. Inspection and Maintenance Schedules. Parts Ordering. Specifications WARNING WARNING

Table of Contents Want full page pictures with most important parts labeled in the beginning.

White Paper. Electrical control valve actuators on oil and gas production separators

OIL SUPPLY SYSTEMS ABOVE 45kW OUTPUT 4.1 Oil Supply

ABRASIVE SYSTEM ABRASIVE REGULATOR II 800# BULK ABRASIVE DELIVERY POT Abrasive Regulator II and 800# Pot Manual

Operating Manual ALU 7 - ALU 10 - ALU 20 - ALU 26 ALU 35 - ALU 60 - ALU 100

TOPLINE ELECTRONICS LTD CO2 CONTROL UNIT MANUAL

HORIZONTAL BLADDER TANK

hydro-pac, inc. Low-Pressure Gas Compressors 1500 to 6000 PSI

NGP-250/500 Nitrogen Generator Quick Start Guide

ALU-CD 12, ALU-CD 25, ALU-CD 35, ALU-CD

AC : ACCURATE CRYOCHAMBER FOR A SMALL LABORATORY WITH SMALL BUDGET

Turnkey Industrial Gas Projects and Equipment

Automatic LN2 Fill Station Instructions

Reverse Osmosis System Installation Guide and Operation Manual.

Oxford Instruments Plasma Technology. PlasmaPro NGP80. Installation Data Sheet. Original Instructions.

OPERATION MANUAL NTF-60 Plus

APPS-160 Gen 2 User Manual

CHE Well Testing Package/Service:

Equipment and Accessories. ROMIL LiQuiSure. Designed for High Purity Containment & Dispensing PURE CHEMISTRY

Innovative Pressure Testing Equipment

Operating Instructions Part No

In Vessel Composter Installation & Commissioning Manual

SEPARATION SYSTEMS. Separator (MBD-1600) or the Wet Oil Tank, (ABJ-1800). Water is

Precision Hydrogen (All B&W Screen Models)

WATER MADE EASY MARINE ENERGY MUNICIPAL INDUSTRIAL

OPERATING INSTRUCTIONS AND PARTS LIST AUTOMATIC FILLING MACHINE DE-401-GB-AUTO

Liquid Helium Bath Cryostat

Tentec. Instruction Document. Mini Air Driven Pump Unit Model: HTT.627X Series. Part Identifier

UBEC 1AT. AUTO TANK Fill System Installation, Operation, & Setup Instructions

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

V10K GAS FEED SYSTEM WALLACE & TIERNAN PRODUCTS

Sweeper Dual Control. Automatic Sweeper Switching System SW SERIES SWEEPERS SW-4815 SW-4820 SW-4825 MAGUIRE PRODUCTS INC.

Valve test benches. Systems overview

KRONES filling systems for beer Filling of glass containers and cans

Cryogenics is the science of ultra low temperatures. Low temperatures are achieved by the liquefaction of gases.

Pump On Demand. Skimmer System

SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER

Air Operated Hydraulic Pumping Systems to 50,000 psi

Gas Cabinets and Valve Manifold Boxes: Applying CGA G13- Rev 2015 to Gas Delivery Equipment

Installation, Operation and Maintenance Instructions for Mild Steel Buffer Vessel

Installation, Operation and Maintenance Instructions Buffer Vessel OM006

Instructions for SILEX 1C Mixed bed cartridge filter

PREVENTION OF EXCESSIVE PRESSURE DURING FILLING OF CRYOGENIC VESSELS

DEPARTMENT OF CHEMICAL ENGINEERING INDIAN INSTITUTE OF TECHNOLOGY MADRAS CHENNAI , INDIA

Pneumatic spool valve islands

Inert Air (N2) Systems Manual

Medical Gas Control Panel

CENTRAL GAS SUPPLY SYSTEMS : CYLINDER BATTERIES AND HIGH PRESSURE HOSES

CRYO INDUSTRIES. Liquid Helium Research Dewars

Liquid Level Controllers

Vacuum Insulated vertical cryogenic CO 2 & N 2 O Tanks

Adsorption Unit Operating Procedures: CO2 Adsorption on to Activated Carbon

MicroBulk Solutions. Next Generation Solutions for Safe and Efficient Delivery for Gas and Liquid Applications

Pressure Differential Automatic Manifold For LPG. PDH1000 Series. LPG Installation & Operations Instructions

Vaporizer Piping Liquid Chlorine Manifolds

D R A F T. Operating Procedures for the NPDGamma Liquid Hydrogen Target at the BL 13. Version 1.00

DRAFT. Operating Procedures for the NPDGamma Liquid Hydrogen Target in TA-53, Building MPF-35

MODEL NUMBER: PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank

GUIDELINES. Systems. Pressure

Cold-acclimatised pipelines

AC : MEASUREMENT OF HYDROGEN IN HELIUM FLOW

Transcription:

from Thames Cryogenics Ltd Total Cryogenic Solutions Cryogenic Cluster Day 22/09/2010

Dewar vessel noun. A container with an evacuated space between two walls, capable of maintaining its contents at a nearconstant temperature over relatively long periods of time. Dewar

Suitable for all manual filling applications Handle Rigid filling tube Sinter Sinter shroud Variable length and diameter. Simple decant hose

Safety improvement for manual decanting Fail-safe Uncomplicated No services required. Mechanical dead-man s handle

Improvements over mechanical DMH Easier to use Space Push button can be remote from decant point But does require electrical supply and possibly pneumatics. Push-to-fill

For end of line decant points, combination with a gas vent system pre-cools line and prevents large gas discharge Interface prevents operation until gas vent has operated. Push-to-fill combined with gas vent

For sites with a high pressure tank Deals with inlet pressures up-to 20 bar Provides freeventing liquid for open dewar filling Variant available with level sensor for auto filling. Pressure-reducing open dewar filling station

Features Manual valve Filter Pressure reducing valve Phase separator Vacuum insulated exhaust Manual decant flexible Wall or floor mounted on frame. Pressure-reducing open dewar filling station

For the filling of pressurised dewars (liquid cylinders) from a bulk tank Automated fill Deals with any size dewar Can be sited inside buildings if required Reduces pressure from source if required Pressurised dewar filling station

Temperature controlled Optional proximity sensors Relief valves combined for ease of piping away Wall or floor mounted on frame Optional swipe card system for access and logging. Pressurised dewar filling station

Where multiple dewar fill stations are required Combined control panel Combined feed and vent streams. Multi-pressurised dewar filling station

Current ways of getting LN 2 to areas that are remote from the supply point Manual handling of dewars from delivery point to use point Vacuum jacketed pipework from bulk tank to use point. ISIS Internally Sited Intermediate Storage

Drawbacks with manual handling of dewars Physical weight of a full dewar (up to 1/3 tonne) means any risk assessment will advise against moving them Weight of liquid is supported on thin neck tube in dewar which is prone to damage if dewar is not moved carefully, particularly across uneven ground Use point may be on a different level meaning that the dewar needs to be placed within a lift!!! ISIS Internally Sited Intermediate Storage

Drawbacks with piping systems Systems which are run dry can have long waiting times to get liquid at use points. Multiple decants of small volumes during a day result in the pipe being cooled frequently and high losses Systems which are run wet have static losses which can be quite high. Keeping a pipeline full of liquid means throwing away liquid. ISIS Internally Sited Intermediate Storage

Thames Cryogenics have developed the ISIS system to overcome these problems Essentially we have created a hybrid system that gives all the convenience of liquid on demand without the penalty of high liquid consumption and importantly ticks all the boxes with respect to safety In a nutshell the dewar remains in the room or location where liquid is required and is filled once a day, automatically via a vacuum superinsulated pipeline. ISIS Internally Sited Intermediate Storage

Components of an ISIS Pressurised dewar Can be existing, user owned or leased or supplied as part of a new package QPL3K control panel A highly sophisticated, programmable control panel that controls filling, decanting and venting and can be wired to depletion systems to shut-down in an emergency. Can be configured to fill on a timed basis or when the dewar has reached a preset level. Can also be used with key card access to prevent unauthorised use ISIS Internally Sited Intermediate Storage

Components of an ISIS (contd) Valve arrangement mounted on a frame for ease of installation, utilising high reliability valves and designed to allow all safety valves and vent valves to be piped away to a safe area Vacuum superinsulated pipework to convey liquid to the ISIS from a bulk tank with a minimum of boil off. ISIS Internally Sited Intermediate Storage

Result Liquid on demand for either manual decanting or for automatic feed into other equipment Minimal losses in pipework system Removal of hazardous handling of pressurised dewars Enclosed system of flow and return so gas generated during filling is piped safely away Links to detection systems and BMS to ensure full monitoring and safety. ISIS Internally Sited Intermediate Storage