Size Selection & Installation of QSZH-125

Similar documents
OC Panel High Limit Aquastat Kit, Manual Reset p/n

Teledyne Oil & Gas North Williamson Blvd. Daytona Beach, FL USA (phone) (fax)

HST-3000 VDSL QUICK CARD

AD-3050 Seal Test Equipment

Infrared Thermography Inspection Guidelines. Date Issued:

Rigel 601 CHECKBOX. Instruction Manual. 348A551 Issue 2.0. April Seaward Electronic Ltd. Issue 2.0

Best Practice for Calibrating LTH Conductivity Instruments

ALTERNATIVE INSTALLATION PROCEDURES FOR 90 AND 45 KTKK MOULDED PART AND ADAPTOR ASSEMBLIES

INTERACTION BETWEEN WIND-DRIVEN AND BUOYANCY-DRIVEN NATURAL VENTILATION Bo Wang, Foster and Partners, London, UK

A hose layline contains important information for specifying the replacement assembly: manufacturer, hose trade name, working pressure and hose ID.

Vibrating Wire Load Cell (3, 4, 5 And 6 Gauge Cells) User Manual

TANK MANAGER FOR TWO TANKS OPERATING MANUAL. 10/31/11 C-More T6C L color touch panel

INSTALLATION PROCEDURES FOR COATED RAYATEN MOULDED PARTS ONTO D-SUBMINIATURE CONNECTORS

Translation of the original Operating Instructions for HKS rubber compensators

HumiSys HF High Flow RH Generator

Rapidmain Installation Guide

May08 Rev B

ES18 Security Theory/Regulations Answer Schedule

Instruction and Maintenance Manual

GENERAL APPLICATION NOTES

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

Importance of Wave Height Measurement in Wave Solder Process Control

DTG - LCD Digital Temperature Gauge USER MANUAL

ASSE International Product (Seal) Listing Program

deltaflowc deltaflowc Venturi or Probe

Constant Pressure Inlet (CCN) Operator Manual

QPEO2/037N Credit Value: 15 QCF Level: 2 GLH: 68 Maintaining electrical equipment/systems

L 100. Bubble-Tube Level System. Installation, Operation and Maintenance Instructions

Dissolved Oxygen Guide

T EK-SUB 4800C 19 mm Submersible Level Transmitter

COMPARISON OF DIFFERENTIAL PRESSURE SENSING TECHNOLOGIES IN HOSPITAL ISOLATION ROOMS AND OTHER CRITICAL ENVIRONMENT APPLICATIONS

SG36KTL-M Quick Installation Guide. 1 Unpacking and Inspection

Pulsed Eddy Current (PEC) Inspection through Insulation

Cover Page for Lab Report Group Portion. Head Losses in Pipes

Best Practice Guide, Servomex 2700

POWR-BLOKS Distribution/Splicer Blocks and Covers

Ground Fault Circuit Interrupter(GFCI) Policy

INSTRUMENTS A THERMAL MASS FLOW SENSOR USING A CONSTANT DIFFERENTIAL TEMPERATURE ABOVE THE AMBIENT GAS TEMPERATURE

TWC Services, Inc. Structured On-The-Job Training for JT- 1, 2, 3

The Outer Seal is highly abrasion resistant and provides mechanical stiffness to the splice in order to better match the cable stiffness.

C&G 2395 Exam Paper April Section A - All questions carry equal marks. Answer all three questions. Show all calculations.

Circuit diagnosis. Plan of attack Testing techniques and analysis. Failures causes and patterns

VI.D AIR DISCONNECT SWITCHES

Agilent Wedge for Probing High-Pitch ICs A Hands-Free Solution for Probing Fine-Pitch ICs

Thermal Profiling the Reflow Process

How to specify a product. Process Sensors and Mechanical Instruments

STANDARD OPERATING PROCEDURES. Andersen Instruments Federal Reference Method (FRM) Ambient Particulate (PM 10 /PM 2.

Tank Continuous Liquid Level Detector

Preferred Instruments Danbury, CT USA

Standard Pneumatic Test Procedure Requirements for Piping Systems

General maintenance engineering applications

Instruction and Maintenance Manual

Installation, operating and maintenance Instructions for Seemag bypass level indicator

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

Oxygen Dialflow Meter. Instructions for Use

General maintenance engineering applications

Instrumentation & Data Acquisition Systems

Mass Spec will not Autotune

Sizing Pulsation Dampeners Is Critical to Effectiveness

TC65M/15M TEMPERATURE CALIBRATOR USER S MANUAL

CCSSL35 Carry out the wiring and testing of electrical circuits and equipment

Level MEASUREMENT 1/2016

Instructions for SMV 3000 Multivariable Configuration (MC) Data Sheets

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

CHAPTER 3 RESULTS AND DISCUSSION

Calculating Total Uncertainty of Temperature Calibration with a Dry Block. Calibration White Paper. Beamex.

AVK SERIES 601, 602, 603 & 605 UNIVERSAL COUPLINGS, ADAPTORS & END CAPS INSTALLATION, OPERATION & MAINTENANCE MANUAL

Maintaining electrical equipment/systems

RADIATION PROCEDURES MANUAL Procedure Cover Sheet

ESA Elbow Sealing Adapter Kit

General Requirements of the NEC Advanced Course. Building Officials and Inspectors Educational Association

_ pressure transducers. User Manual

Gas Network Craftsperson

Use equation for the cylindrical section and equation or for the ends.

Polatrak ROV II - Tip Contact Probe Operation Manual

Current Leads for Cryogenic Systems

PROCESS MONITORING AND CONTROL

Aquavar SOLO 2 Frequently Asked Questions

OIL & GAS. 20th APPLICATION REPORT. SOLUTIONS for FLUID MOVEMENT, MEASUREMENT & CONTAINMENT. Q&A: OPEC Responds to SHALE BOOM

New Thinking in Control Reliability

The Science Behind Conveyor Oven Thermal Profiling

The Best Use of Lockout/Tagout and Control Reliable Circuits

DRILL MAINTENANCE ADJUSTMENTS BEFORE GOING TO THE FIELD

Testing of Active Flow Control actuators at harsh environment

CRANE WITH WINCH USE AND MAINTENANCE MANUAL. Code Rev. Release MD /03

DISTILLATION POINTS TO REMEMBER

TG GUIDELINES CONCERNING CALIBRATION INTERVALS AND RECALIBRATION

MACH ONE MASS FLOW CONTROLLER. MACH ONE SERIES flow control. MASS FLOW CONTROLLERS at the speed of sound.

RESISTORS, HEATERS, FLEXIBLE, SINGLE AND DOUBLE LAYER. ESCC Detail Specification No. 4009/002

Gilson Aqua-Check Moisture Tester MA-26X

Model 23H Hand Crank Seamer

Product information. Capacitive. Level detection in liquid VEGACAP 62 VEGACAP 63 VEGACAP 64 VEGACAP 66 VEGACAP 69. Document ID: 29983

Overspeed governors (113 OG Моment 250 MR, 114 OG Moment 250 A3, 115 OG Moment 250 MRL, 119 OG Moment 250 MRL/1)

A REVIEW OF THE 2000 REVISIONS TO ANSI 2530/API MPMS 14.3/AGA REPORT NO. 3 - PART2 Paul J. LaNasa CPL & Associates

Over 20,000 Strain Gage Target flowmeters installed since 1952.

Mounting and Operating Instructions EB 2172 EN. Series 43 Temperature Regulators. Type 43-5 and Type Type Type 43-6

CONTROL and INSTRUMENTATION

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

Malema Sensors M-2700 Integrated Ultrasonic Flow Meter

MODELS (2 foot Version) (4 foot Version)

Transcription:

Product Installation Procedure (PIP) No: PIP-101 Revision: 2 Dated: January 2012 Title:- Size Selection & Installation of QSZH-125 Prepared By: Name: Clive Benning Date: January 2012 Reviewed & Approved By: Name: Kurt Joachim Date: January 2012 Note: This document is electronically reviewed and approved - therefore no signature will appear Page 1 of 21

Contents 1 Scope... 3 2 Revision History/ Reason for Change/ Related Documents... 3 3 Introduction... 3 4 Splice Design & Preparation Guidelines... 4-8 Page 5 Tube Size Selection & Installation Guidelines... 9-12 6 Sealing Verification/ Visual Standards... 13-16 Appendix 1 General Wire Chart... 17-18 Appendix 2 UHI-250A Thermal Probe... 19 Appendix 3 Test Methods... 20 Appendix 4 Trouble Shooting... 21 Page 2 of 21

1 Scope This document details the important aspects of splice design together with selection and installation criteria when using TE Connectivity QSZH-125 splice sealing products. 2 Revision History / Reason for Change / Related Documents Rev Date Prepared By Doc Approved By CR No. New Product. Initial document. 1 February 2008 Barry Jenkins Joao Rocha New document 2 January 2012 Clive Benning Kurt Joachim CR12-DP-041 Reason for Revision: Related Documents: Review content and update product references. TE Connectivity Flier - RBK-ILS-MK2 Processor Maintenance & Repair Manual TE Connectivity Flier - Seal Test equipment AD 3050 No. TFAE0043 THFIT/MR/020 TFAE0017 3 Introduction This guide has been produced to aid the splice designer and user of TE Connectivity QSZH-125 adhesive lined tubing to select the most appropriate size and installation conditions to produce optimum results for an environmentally sealed splice. The document has three main sections: Section 4 Section 5 Section 6 Splice Design and Preparation Guidelines Tube size selection and installation guidelines Sealing verification guidelines NB: The recommendations presented here are based on general industry information. Since TE Connectivity does not have knowledge of the specific application and the end use conditions of all users, each user should determine the correct size of tubing together with the installation conditions for their own application and evaluate the splice against individual requirements. (Refer to TE Connectivity to ensure latest issue of this document). Page 3 of 21

4 Splice Design and Preparation Guidelines 4.1 Splice Design There are many factors, which can influence the successful installation of a heat shrink sleeve for splice sealing. These include: i) ii) iii) iv) total number of wires; number difference of wires between each side; cumulative insulation cross-sectional area; cumulative insulation cross-sectional area difference between each side. Generally for splices having no more than 4 wires per side the installation and sealing characteristics are excellent. For splices having 5 to 7 wires per side the configuration is more complex and corresponding installation times are likely to be longer and the installation window smaller. Consequently, these splices may require additional work in establishing production installation conditions. For optimum performance and compatibility it is recommended that T3 (125 C) rated wire be used and the following guidelines followed: Tubing Size Parameter Nr 1 Nr 2 Nr 3 Nr3A Nr 4 Maximum number of wires per 7 7 7 7 7 side Min./max. CSA range (mm 2 ) NB1 1.3 to 12 3 to 20 5 to 35 15 to 60 30 to 85 Preferred maximum CSA 8 12 22 30 35 difference between sides of splice (mm 2 ) Absolute maximum CSA difference between sides of splice (mm 2 ) 11 14 28 40 50 NB: See also the splice balancing matrix which pictorially shows additional guidelines with respect to both number of wires per side of splice and difference in CSA (cross sectional area). NB 1: Due to variations in wire insulation thickness between manufacturers of similar gauge wires, the cross-sectional areas shown above relate to the cumulative areas of a splice using the outside diameter, of each wire insulation, in the calculation. Splices outside of these recommendations will require extensive testing to ensure that reliable sealing of the splice can be consistently achieved. Page 4 of 21

SPLICE BALANCING MATRIX: TE Connectivity QSZH-125 NR 1 NR 2 Maximum number of wires on one side 7+ 7 4 1 0 8 11 Difference in CSA mm 2 Maximum number of wires on one side 7+ 7 4 1 0 12 14 Difference in CSA mm 2 17 NR 3 NR 3A Maximum number of wires on one side 7+ 7 4 1 Maximum number of wires on one side 7+ 7 4 1 0 22 28 Difference in CSA mm 2 30 0 30 40 Difference in CSA mm 2 45 NR 4 Excellent Sealing Complex Geometry Not Recommended Maximum number of wires on one side 7+ 7 4 1 0 35 50 Difference in CSA mm 2 55 Page 5 of 21

4.2 Splice Preparation Guidelines The splice can be constructed by conventional techniques such as resistance welding, ultrasonic welding, or mechanical crimping or clip and dip. The strands of the conductor must be completely captured in the nugget or crimped area. There should be no loose strands, especially those pointing upwards which could poke-through the tubing material during installation. It is important to ensure that the distance from the welded nugget or crimp, to the wire insulation is 3.5 ± 1.5mm to allow the adhesive sufficient space to flow and seal between the wires (see Figures 1 & 2). The copper wire strands from opposing sides of the splice must not compromise this dimension. Additionally, the wire around the splice should be essentially free of dirt, oil, solder, flux and moisture for optimum performance. Figures 1 & 2 (see over) Page 6 of 21

Figure 1 Splice preparation guidelines ( Ultra sonic welded splices) 2 to 5mm 2 to 5mm QSZH-125 PRIMARY CRITICAL SEALING ZONE SECONDARY SEALING ZONE 2 to 5mm 2 to 5mm Loose strand Page 7 of 21

Figure 2 QSZH-125 Splice preparation guidelines (Crimped splices) PRIMARY SEALING ZONES GOOD 2 to 5mm SECONDARY ZONES 2 to 5mm EXCESS OVERLAP OF WIRE STRANDS BAD BAD RISK OF POKE THROUGH Page 8 of 21

5 Tube Size Selection and Installation Guidelines 5.1 5.1.1 Tube Size Selection Wire insulation diameters for a given gauge of wire can vary depending on the manufacturer. This will influence the cumulative cross sectional area of the wire bundle in the splice. A general chart showing nominal wire insulation OD (mm) and corresponding cross sectional areas (mm 2 ) is given in this guide (Section 6). However, it is recommended that the simple calculation shown in 5.1.1 and Fig 3 be followed to determine the cumulative cross sectional area more accurately for each side of the splice. Cumulative Cross Sectional Area Figure 3 SIDE 1 (S1) SIDE 2 (S2) A B C D E F S1 = 0.8 (A 2 + B 2 + C 2...) S2 = 0.8 (D 2 + E 2 + F 2...) Where S1 = Cumulative area of side 1 S2 = Cumulative area of side 2 A Diameter of wire A B Diameter of wire B C Diameter of wire C D Diameter of wire D E Diameter of wire E F Diameter of wire F Note: /4 0.8 Page 9 of 21

5.1.2 Tubing Size Range Table When the cumulative areas for each side of the splice have been determined use the Table below to find the smallest tube size which can accommodate both values, e.g. : S1 = 3 ) Use # 1 S2 = 11 ) S1 = 15 ) Use # 3 S2 = 23 ) NB: When mechanical crimping techniques are used it may be necessary to use the next largest tube size. QSZH-125 TUBING SIZE RANGE TABLE 30 85 Nr 4 15 60 Nr 3A 5 35 Nr 3 3 20 Nr 2 1.3 12 Nr 1 0 10 20 30 40 50 60 70 80 90 Cumulative cross sectional area based on wire insulation OD (mm²) Page 10 of 21

5.2 Installation Guidelines Installations can be carried out using various techniques including discrete or belt type heaters, the selected method being dependent on production area layout and required throughput. It is important that TE Connectivity installation equipment be maintained in a state of calibration using an UHI-250A thermal probe as described in the RBK-ILS-MK2 Processor Maintenance & Repair Manual THFIT/MR/020. The installation window will be dependent on the set point temperature of the equipment, geometry and preparation of splice and the size of tubing. Generally the installation window will be small if the splice geometry is complex and the equipment set point high. For lower temperature set points the window will be larger but the corresponding installation time will be longer. Generally, it is recommended that discrete heaters such as the TE Connectivity RBK-Processor be set at 450-500 C, and the Model 19 belt heater at 550 C. It is recommended that heat input as seen by the splice to be installed be measured via an UHI-250A Thermal Probe. (PCN: 288869, CLT-EQUIP-UHI-250A-PROBE. Refer to Appendix 2 for explanation of the Thermal Probe.) Verification of sealed joints can be determined as outlined in Section 6. 5.2.1 Installation Method 5.2.1.1 Determine tube size per section 5.1 5.2.1.2 Ensure installation equipment has been switched on for a minimum of 30 minutes to stabilize. 5.2.1.3 Recheck for loose wire stands and wire insulation cut back. Centrally locate the tubing onto the splice and position centrally within the heating zone of the application equipment. (See Figures 4 & 5) 5.2.1.4 Run the splice through the heating equipment; record the installation conditions, i.e. processor time/set point, or belt heater speed/set point. Run the UHI probe through at the same conditions to obtain the UHI temperature. 5.2.1.5 Increase the UHI probe temperature by 5-10 C increments by changing the processor time in 1-2 second steps or belt heater speed (not the set temperature) until the wire insulation or tubing jacket material shows visual signs of damage. (This is the upper limit of the installation window.). 5.2.1.6 Check all splices for sealing efficiency (0.5 bar air pressure per section 6). If the sample installed at the lowest UHI sealing temperature passes then lower the UHI probe temperature by 5-10 C increments until a sealing failure occurs. 5.2.1.7 Prepare 5 sample splices at the minimum conditions, which gave a pass result when tested per section 6. If all 5 pass, this can be regarded as the lower limit of the installation window. If failures occur raise the UHI probe temperatures as previously until 5 from 5 pass to give the lower limit. If damage is seen before sealing is achieved, then the splice configuration may need re-designing. In order to optimise sealing efficiency in a production environment it is recommended that the mid point between upper and lower limit be used. Page 11 of 21

Note: Sealing time for a given splice will depend on its complexity, number of wires and the wire type. In accordance with the above procedure the following times are offered as approximate start points for determining the installation window of a particular splice when using the following TE Connectivity Installation Equipment and may need to be adjusted up or down accordingly. MK2 Processor Set Temperature 450 C 500 C Time (seconds) QSZH-125-NR1 7 QSZH-125-NR2 11 QSZH-125-NR3 12 QSZH-125-NR3A 15 Model 19 Belt Heater 550 Belt Speed Belt Speed Indicator setting (actual belt speed) QSZH-125-NR1 600 (914mm/min) QSZH-125-NR2 QSZH-125-NR3 QSZH-125-NR3A QSZH-125-NR4 500 (762mm/min) 400 (610mm/min) 300 (457mm/min) 200 (305mm/min) Page 12 of 21

Figure 4 QSZH-125 Visual standards before installing tubing (Ultra sonic welded splices) 2 to 5mm 2 to 5mm Check for gap between weld and wire Check for loose Centralise the splice and the tubing in the equipment Page 13 of 21

Figure 5 Visual standards before installing tubing (Crimped splice) 2 to 5mm 2 to 5mm QSZH-125 Check for gap between crimp and wire insulation RISK OF POKE THROUGH Check for loose strands Centralise the splice and the tubing in the installation equipment Page 14 of 21

6 Sealing Verification / Visual Standards 6.1 Test Methods A variety of test methods exist which are incorporated by many major Automotive OEM s to determine the environmental integrity of an installed splice including: 1. Current Leakage 2. Insulation Resistance 3. Air Pressure a) Not suitable for splices manufactured by clip and dip. b) Will not detect poke-through. Refer to Appendix 3 for Test Methods. For speedy determination of splice installation windows it is recommended that an air pressure test be used. Experience has shown excellent correlation between this method and Insulation Resistance/Current Leakage techniques for most types of splices. TE Connectivity Seal Test equipment AD 3050 has been found to be acceptable (for details see TE Connectivity Flier No TFAE0017). It can also be used to monitor sealing efficiency periodically throughout a production run. Final verification should be per OEM specification. Page 15 of 21

6.2 Visual Standards QSZH-125 Visual Standards after Installation 1. Under installed 2. Over heat of tubing 3. Over heat of wires 4. Tubing off centre and wire exposed 5. Tubing off centre (verify sealing) 6. Wire strand poke through 7. Acceptable Page 16 of 21

Appendix 1: General Wire Chart Approximate Cross Sectional Area based on wire insulation diameter (mm 2 ) Nominal Number of Wires OD (mm) 1 2 3 4 5 6 7 1.4 2 3 5 6 8 9 11 1.5 2 4 5 7 9 11 12 1.6 2 4 6 8 10 12 14 1.7 2 5 7 9 11 14 16 1.8 3 5 8 10 13 15 18 1.9 3 6 9 11 14 17 20 2.0 3 6 9 13 16 19 22 2.1 3 7 10 14 17 21 24 2.2 4 8 11 15 19 23 27 2.3 4 8 12 17 21 25 29 2.4 5 9 14 18 23 27 32 2.5 5 10 15 20 25 29 34 2.6 5 11 16 21 27 32 37 2.7 6 11 17 23 29 34 40 2.8 6 12 18 25 31 37 43 2.9 7 13 20 26 34 40 46 3.0 7 14 21 28 35 42 49 3.1 8 15 23 30 38 45 53 3.2 8 16 24 32 40 48 56 3.3 9 17 26 34 43 51 60 3.4 9 18 27 36 45 54 64 3.5 10 19 29 38 46 56 67 3.6 10 20 31 41 51 61 71 3.7 11 22 32 43 54 65 75 3.8 11 23 34 45 57 68 79 3.9 12 24 36 48 60 72 84 Page 17 of 21

Appendix 1: General Wire Chart (continued.) Approximate Cross Sectional Area based on wire insulation diameter (mm 2 ) Nominal Number of Wires OD (mm) 1 2 3 4 5 6 7 4.0 13 25 38 50 63 75 88 4.1 13 26 40 53 66 79 4.2 14 28 42 55 69 83 4.3 15 29 44 58 73 87 4.4 15 30 46 61 76 4.5 16 32 48 64 80 4.6 17 33 50 66 83 4.7 17 35 52 69 87 4.8 18 36 54 72 4.9 19 38 58 75 5.0 20 39 59 79 5.1 20 41 61 82 5.2 21 42 64 85 5.3 22 44 66 88 5.4 23 46 69 5.5 24 48 71 5.6 25 49 74 5.7 26 51 77 5.8 26 53 79 5.9 27 55 82 6.0 28 57 85 6.1 29 58 87 6.2 30 60 6.3 31 62 6.4 32 64 6.5 33 66 6.6 34 68 6.7 35 70 6.8 36 73 6.9 37 74 7.0 38 77 7.1 40 80 7.2 41 81 7.3 42 84 7.4 43 86 7.5 44 88 7.6 45 7.7 46 7.8 48 Page 18 of 21

Appendix 2: UHI-250A Thermal Probe UHI-250A UHI-250A (pcn 288869) The heat applied to a splice is conveniently measured by a TE Connectivity UHI-250A Thermal Probe. This Thermal Probe has a known mass of aluminium with fixed dimensions and a thermocouple embedded in the aluminium. The theory of use of the Probe is derived from the equation for calculating the quantity of heat required to raise a mass from one temperature to another. Q = Mkc (t 2 - t 1 ) Where Q = Quantity of Heat M = Mass k = units constant c = specific heat t 1 = ambient temperature t 2 = final temperature When using the probe, M, k, c and t 1 are constant so that the final temperature (ignoring heat loss) is proportional to the quantity of heat. t 2 = Q The temperature rise of the aluminium is proportional to the heat received during the time the Probe is in the heat zone of the heater. By relating this temperature to the sealing performance of a given splice the window for this splice can be defined. The lower point is the lowest temperature at which the splice seals and the upper point the highest temperature at which no thermal damage is observed. The best probe temperature (quantity of heat) for a given splice is normally set at the midpoint of the window. This midpoint temperature is best determined in the manufacturing environment where the splice is to be sealed. The UHI-250A Thermal Probe is available through your local TE Connectivity Office (PCN: 288869). Page 19 of 21

Appendix 3: Test Methods Current Leakage: Test Method Immerse the centre section of the specimens in a water bath containing 5 percent by weight of sodium chloride (23 ± 2 C). Check for current leakage after 24 hours immersion. Applied test voltage is 50V dc. Take the reading after 60 seconds. The splice shall be considered sealed if current leakage is less than 0.25 micro amps Spice 5% NaCl Solution Current meter 50 volt Insulation Resistance: Test Method Immerse the centre section of the specimens in a water bath containing 5 percent by weight of sodium chloride (23± 2 C). Check for Insulation Resistance after 24 hours immersion. Applied test voltage is 100V dc. Take the reading after 60 seconds. The splice shall be considered sealed if the Insulation Resistance is greater than 2 x 10 8 ohm Splice 5% NaCl solution Resistance meter 100 volt Air Pressure: Test Method Immerse the centre section of the specimens in a water bath. Connect both ends to a regulated air supply and apply 0.5 bar for 1 minute. If no bubbles arise from the splice area sealing is considered acceptable. Final verification should be per OEM specification. 0.5 bar Splice 0.5 bar Page 20 of 21

Appendix 4: Trouble Shooting Fault Possible Cause Solution Sleeve not fully shrunk onto splice Insufficient heat Increase heat. Check UHI-250A reading Insufficient time Increase time in heater element Sleeve incorrectly positioned after installation (milk-off) Sleeve partially recovered at one end Sleeve or wire overheated Sleeve scorched on one side Sleeve splits Wire strand pokes through tube Cannot seal splice Wire damage at sleeve edge but sleeve visually OK Wrong tube size selected Incorrect location prior to installation Splice unbalanced Splice did not align centrally in application equipment Excessive heat Excessive wire curvature Splice located incorrectly in machine Sharp edge of nugget/crimp Wire strand loose Excessive heat Wrong tube size selected Wire strand loose from welding or crimp Inadequate heat Incorrect size of tube Too many wires Contamination on wires Inadequate sealing zone Excessive heat Splice not centered in machine Mismatch of tube/wire Temperature rating Re-assess tube selection Locate correctly (offset tube accordingly) Use alignment guide on heater Redesign splice if possible Consult local TE Connectivity representative Use guidelines on machine for centralisation Check calibration Reduce installation time or temperature Check calibration Use straightened wire Reposition splice Check welder/crimp tooling Reduce installation time or temperature Re-assess tube selection Check welder/crimp tooling Check splice construction Increase installation time or temperature Refer to sizing guide Reconstruct splice Clean splice Check splice manufacturing process Check equipment calibration Reduce installation time or temperature Use guides on machine Page 21 of 21