HP/UHP Spring-Loaded Regulator

Similar documents
SPECIFICATIONS. Approximate Weight: 10 oz. Surface Finish: Ra micro inch or less MATERIALS OF CONSTRUCTION

Relief Valves. Relief Valves. International, Inc. Company ACIRCOR. RS Differential NB 9.5mm. RVA In-line Differential NB 6 to 19mm

Description Advanced Features Typical Applications

Petro-Chemical & Analyzer Sampling Systems

JSR Series. Sanitary Valves JSR Series Ultra-High Pressure Reducing Valves. High Purity Bio-Pharma Gas Pressure Reducing Valves.

1200 Series Pressure Regulators

Compact Regulator. ARX20 Series. 2.0 MPa compatible, piston type compact regulator ARJ

Petro-Chemical & Analyzer Sampling Systems

Regulators. For ultra high purity (UHP) For UHP gas delivery in semiconductor and other clean industries. AP1600/AP1900 AP1200. AP Series P.

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301

Tank Blanketing Pressure Regulators RHPS Series

Model PRS-07i. Stainless Steel Low Pressure, In-Line Pressure Regulator (Reducing Valve)

shutoff valves 900 Series psig Manual Shutoff Valves

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401

Precision Pressure Regulators. Precision Fluidics

Operation Manual. Diaphragm Sensed Gas Pressure Regulators

Specialty Gas Equipment Catalogue

780S Ultra High Purity Series

MEGR-1912 Instruction Manual

Operation Manual Piston Sensed Gas Pressure Regulators

PRO-50 Instrument Supply Regulator

Bourdon Tube Pressure Gauges Ultra High Purity (UHP) Series Type

JSRH Series. Sanitary Valves JSRH Series High Flow Pressure Reducing Valves. High Flow Bio-Pharma Clean Gas Pressure Reducing Valves

Smooth Vent Valve. Series XVD XL XL Q D- XVD XGT CYV

Standard Operating and Maintenance Instructions for Pumping System Model PS-90

1305 Series Pressure Reducing Regulators

SERIES 30. Spring Operated Tank Blanketing Valve PROTECTOSEAL.

REGULATORS FOR SPECIFIC APPLICATIONS

ALE-40. R06 Miniature Brass Body Regulator. Water and Compressed Air Service 1/8" and 1/4" PTF Port Sizes. Air line equipment.

Pressure Regulators. Operating Instructions. Instrumentation

JR Series. Gas Pressure Reducing Valve GAS PRESSURE REDUCING VALVE

Inert Air (N2) Systems Manual

THE BP-690 SERIES. Operating and Service Manual. Series includes all variants of BP-LF/MF-690/691

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

JR Series. Gas Pressure Reducing Valves. a division of Jordan Valve GAS PRESSURE REDUCING VALVES

Precision and Instrument Regulators 1/4" port size

Content. 1. Basic Product information. 2. Standard Equipment. 3. Special Gas Equipment. 4. Accessory. 5. Charts 6. GCE - -

Mechanical Pressure Measurement

ALE-32. Miniature General Purpose Regulators R07, R46 (non-repairable) Air line equipment. Technical data

Full Range Pressure Compensating Variable Flow Control

CVI Valve Line. Exceeds the industry s highest standards for reliability and performance

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.

INSTRUCTIONS FOR MODELS APC & APG HIGH PURITY, CORROSIVE GAS REGULATORS

THE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv)

Direct Operated Precision Regulator Modular Style. Standard Specifications

Ball Float Steam Trap UNA 45 MAX, UNA 46 MAX, UNA 46A MAX PN 40/Class 300 DN 40, 50, 65

ZUERCHER MRCib Series

A BRIEF TUTORIAL ON GAS HANDLING EQUIPMENT

A soft sealed atmospheric safety valve with large flow capacity and soft seat tightness for steam condenser and turbine applications

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

Best Practices for Installation of Gaseous Sample Pumps

Ultra High Purity Model 780S

Description Supply pressure Pressure range Connection Device Page max. bar bar thread

COMPONENTS MANUFACTURING

Calibrated or locked versions available. TREATMENT > Series MD regulators GENERAL DATA. New

Installation Operating Instructions for Simple Duplex Manual Manifolds PX-TSD Series

PULSATION DAMPENER / SUPPRESSOR SERIES PDS PROVIDES MULTIPLE SYSTEM SAFEGUARDS

1800C and 1800C-HC Service Regulators

High Purity High Performance Point-of-Use Pressure Regulator

DS05C,D,G Dial Set Pressure Regulating Valves

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

S300 Series. Valve Link. Features. Fisher Controls

R133 HELYON. Brass high pressure regulator, suitable for compressed air, gas and liquid

CVS10 Sanitary Check Valves

Smooth Vent Valve XVD. Series

64 Series Pressure Reducing Regulators

High-Purity. Ball Valves

PTFE-SINGLE GLASS FLOW METERS

VERTICAL BLADDER TANK

Series MX pressure regulators 3/

OPTIBAR P 1010 C Technical Datasheet

Smooth Vent Valve. XVD Series

Pressure Gauges Accessories

JSHM Series Hand Metering Valves

product range overview P.004 P.006 Switch over Boards Quality Standards Pressure Regulator Technology P.013 Technical Parameters

Life Sciences. Pressure control solutions for your industry.

Tank Blanketing Regulators

Gas delivery systems. How to ensure uninterrupted high quality gas delivery from the source to the apparatus? Dr. Gastons Vereskuns Trakai,Lithuania

DIAPHRAGM GAS SAMPLING PUMPS

HORIZONTAL BLADDER TANK

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

LRS(H)4 Pressure-Reducing Regulator User Manual

Propor tional Re lief Valve s

Product Manual. Description. Specifications. CVS Type 1301F and CVS Type 1301G Regulator. Introduction

Precision matters. HiQ equipment for specialty gases.

THE HF-210 SERIES. Operating and Service Manual. Series includes all variants of HF-210/211. Issue A October 2014 *Section 6.

MATHESON s LaserPro Gases and Gas Delivery Equipment

Precision Pressure Regulators

ANDERSON GREENWOOD SERIES 9000 POSRV INSTALLATION AND MAINTENANCE INSTRUCTIONS

Test Report # Rev 0. Adiabatic Compression In Nitrogen Service

670 Series Panel-Mounted Loading Regulators

ACCUMULATOR OPERATING & MAINTENANCE INSTRUCTIONS

Model 10. Low-Medium Pressure Reducing Regulator

Proportional Relief Valves

1213B2 Service Regulators Maximum Inlet Pressure 125 PSIG

Tank Blanketing Regulators

VACUUM REGULATORS CONTENTS

World Area Differences Technical Information

Pressure Relief Valve DHV 718

v. Size shall be specified on drawings.

Transcription:

Description HP (High Purity) and UHP (Ultra High Purity) products are for service where the product must be kept free of contamination. The design is kept simple to minimise dead areas where contaminants might collect. Elastomers are not used and polymers are carefully selected for suitability. UHP uses the same design as HP but the parts are machined to a better surface finish to improve cleanliness. The valve is assembled in a clean room and is Helium leak tested by mass spectrometer. HP/UHP products may be used on reactive, corrosive and/or toxic products. Special materials are available for resistance to particularly aggressive chemicals. We offer a range of spring-loaded regulators that provide a flow of gas at controlled pressure. The outlet pressure is set by turning the control knob. A diaphragm isolates the process fluid from the spring compartment. The range of outlet pressure is set by the diameter of the diaphragm and the strength of the spring. The outlet pressure is substantially unaffected by flow rate but it does drop slightly as the inlet pressure is increased. A back pressure variant is available. This controls the inlet pressure by venting pressure to the outlet if the inlet pressure exceeds the set value. Standard Types HP5 back pressure regulator HP/UHP1T forward pressure regulator with tied diaphragm for low pressure HP/UHP11 high flow forward pressure regulator HP/UHP14 - forward pressure regulator for low absolute pressure HP/UHP155 - low flow forward pressure regulator UHP16 forward pressure regulator with no valve lift spring HP/UHP17 two stage forward pressure regulator Build Standards (UHP only) Built to ultra high purity standards in a dedicated clean room facility. Ra 1 to 15 micro inch finish on wetted surfaces. Final assembly and testing is carried out under class 1 conditions. Each valve is tested for leakage using a mass spectrometer. Leak rate is less than 1-9 mbar l/s of Helium, inboard, outboard and across seat. No lubrication is used in the flow path and the seat materials are chosen for minimal gas absorption.

Standard See next page for specification of individual types Ports: 1/4 NPT female for HP, 1/4 Cajon VCR fittings on welded stubs for UHP (except where stated ) Temperature range: -4 to +1 C Standard Materials Alternative materials can be supplied Body: Stainless Steel or Brass Valve: Stainless Steel, Monel or Hastelloy Valve Seat: PCTFE Diaphragm: Stainless Steel (PTFE coating optional) or Hastelloy Options Please contact us for details Ordering Information Ports: alternative port configurations can be supplied including additional ports for gauges and relief valves. Materials: suitable combinations of materials can be supplied for various applications such as Oxygen service or semiconductor manufacturing. Mounting: all types have threaded mounting holes in the base but an optional threaded bonnet is available for panel mounting. The standard control knob may be replaced by a lever or by a locking cap. A maximum outlet pressure limit stop is fitted as standard but a minimum outlet pressure limit stop is available as an option Steam heated and explosion proof electrically heated variants are available. Certification: variants are available approved for use with Oxygen, for medical Oxygen service or for ATEX service. Some variants have passed adiabatic shock (BAM) tests. Please supply the following information when ordering Cleanliness level Outlet pressure range Forward or back pressure Flow medium Tied diaphragm (where available) Control knob or locked output (state required outlet pressure) Panel mounting required Internal limit stops state maximum pressure Port configuration Operating and storage temperature ranges Certification and QA requirements Panel Mounting and Locked Output Pressure Locked Outlet Cap (Option) Panel Mounting (Option) Lever Control and Outlet Limit Stops Operating Lever (Option) Maximum Limit Stop (Standard) Minimum Limit Stop (Option)

HP5 Back Pressure Regulator Maximum inlet pressure: 17bar (25psi) Outlet pressure ranges: to 2 bar ( to 3psi), to 7 bar ( to 1psi), to 17 bar ( to 25psi) Flow factor (Cv):.12 bar (psi) 13 (2) 11 (16) 8.2 (12) 5.5 (8) 2 4 6 8 1 HP/UHP1T HP5 Increasing Flow Decreasing Flow Maximum inlet pressure: 27bar (3psi) Outlet pressure ranges: to 1.7 bar ( to 25psi), to 3.4 bar ( to 5psi), to 7 bar ( to 1psi), to 1 bar ( to 15psi) Flow factor (Cv):.16 6.9 (1) 6.2 (9) HP1T 2psi 1psi 5psi 2psi Ø45 Ø7 Ø32 17 123 136 5.5 (8) 3.5 (5) 2.7 (4) 2. (3) 1.4 (2) Ø51 18.7 (1) 4 8 12 16 2 24 28 32

HP/UHP11 High Flow Maximum inlet pressure: 31bar (45psi) Outlet pressure ranges: to.7 bar ( to 1psi), to 1.7 bar ( to 25psi), to 3.4 bar ( to 5psi), to 7 bar ( to 1psi), to 14 bar ( to 2psi), to 2 bar ( to 29psi) Flow factor (Cv):.2 Process Ports: 3/8 NPT female for HP, 1/2 Cajon VCR fittings on welded stubs for UHP Pressure Variation** %:.6 Tied diaphragm option available 6.9 (1) 6.2 (9) HP11 5psi 3psi 2psi Ø66 Ø42 26 186 5.5 (8) 3.5 (5) 2.7 (4) 2. (3) 1.4 (2) Ø56.7 (1) 4 8 12 16 2 24 28 32 ** Pressure variation is the RISE in outlet pressure for a DROP in inlet pressure

HP/UHP14 Absolute Pressure This regulator is for use at vacuum and low positive pressure. It includes an internal spring to compensate for ambient pressure. Maximum inlet pressure: 1barg (15psig) Outlet pressure range:.7 to 2.1 bar (1 to 3psi) absolute Flow factor (Cv):.3 1.1 (16) HP14 12psi 7psi 25psi Ø32 127.96 (14).83 (12).69 (1).55 (8).41 (6) Ø58 19.27 (4).14 (2) 14 28 42 56 71 85 1 114 128 156

HP/UHP155 Low Flow Maximum inlet pressure: 376bar (545psi) Outlet pressure ranges: to 2 bar ( to 3psi), to 5 bar ( to 75psi), to 7 bar ( to 1psi), to 1 bar ( to 15psi), to 2 bar ( to 29psi) Flow factor (Cv):.9 Pressure Variation** %:.8 Tied diaphragm option available HP155 25 bar 1 bar 4 bar 13 1 (145) 9 (131) 8 (116) 7 (11) 6 (87) 5 (72.5) 4 (58) 3 (43.5) Ø48 17 2 (29) 1 (14.5) 1 2 3 4 5 6 ** Pressure variation is the RISE in outlet pressure for a DROP in inlet pressure

UHP16 Springless This regulator has no spring in the process flow to eliminate the possibility of contamination from the spring. The diaphragm acts as the valve lifting spring. Because of this the diaphragm is tied to the valve mechanism. This type is only offered as ultra high purity. Maximum inlet pressure: 218bar (3161psi) Outlet pressure ranges: to 2 bar ( to 3psi), to 7 bar ( to 1psi), to 17 bar ( to 25psi) Flow factor (Cv):.9 13.8 (2) 12.4 (18) 11. (16) HP16 2psi 1psi 5psi Ø46 17 12 9.6 (14) 8.3 (12) 6.9 (1) 5.5 (8) 4.1 (6) 2.7 (4) 1.4 (2) 4 8 12 16 2 24 28 32

HP/UHP17 Two Stage This regulator incorporates two stages of regulation in a common body. This significantly reduces the effect of changes in inlet pressure on the outlet pressure. It also reduces the cooling effect of large pressure drops. Maximum inlet pressure: 376bar (545psi) Outlet pressure ranges: to 2 bar ( to 3psi), to 5 bar ( to 75psi), to 1 bar ( to 15psi) Flow factor (Cv):.65 Pressure Variation** %:.64 Tied diaphragm option available 6.9 (1) 6.2 (9) HP17 35 to 3 Ø32 Ø45 16 5.5 (8) 4.8 (7) 4.1 (6) 3.5 (5) 2.7 (4) Ø32 58 2 (3) 1.4 (2).7 (1) 2 4 6 8 1 12 ** Pressure variation is the RISE in outlet pressure for a DROP in inlet pressure