780S Ultra High Purity Series

Similar documents
Ultra High Purity Model 780S

Steel-Mass Model 640S

7Flat-Trak Model 780S. Smart In-Line Thermal Gas Mass Flow Meter with Flow Conditioner. For information online...

Features. Description

Steel-Mass Model 640S

Technical Data Sheet High Performance Digital Gas Mass Flow Meters and Controllers Features Description

Max-Trak Model 180. Technical Data Sheet. NEMA 6 / IP67 Compliant Industrial Mass Flow Meters and Controllers For Gases

C-1500 Series Velocity Transmitter for HVAC Application (Gas, Liquid) C Thermal Mass Flow Meters. Gas & Liquid Type Mass Flow meter

SmartTrak 100HP. Ultra-High Pressure Digital Gas Mass Flow Meters & Controllers. FEATURES DESCRIPTION

SideTrak 830/840. Process Gas Mass Flow Meters and Controllers. FEATURES DESCRIPTION

Pro-V Multivariable Flowmeter

analytical bulk flow distance FLOW level pressure temperature industrial communication

GFM. Typical Aluminum GFM Mass Flow Meter NIST MASS FLOW METERS. Principles of Operation. Design Features

High Performance Digital Gas Mass Flow Meters & Controllers

Design Features. General Description

SmartTrak. High Performance Digital Gas Mass Flow Meters & Controllers. DESCRIPTION

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

For Multi-Parameter Meters see mvx

For Multi-Parameter Meters see mvx

Flow and Energy Measurement F-5400 THERMAL MASS FLOW METER

Mass Ultrasonic / 2006 Flow meter INSTRUMENTS, INC. THE FLOW MEASUREMENT. HVA/C Mass Flow Meter (HVA/C 1510)

PanaFlow MV82. Insertion Style Multivariable Flowmeter. GE Measurement & Control. Key Benefits. Applications

800 Series Mass Flow Meters and Controllers. High Performance Mass Flow Meters and Controllers

Brooks TMF-Zone 1 Models 5816-Ex/5864-Ex

MASS FLOW SYSTEMS MASS FLOW MEASURING, CONTROLLING AND BLENDING SYSTEMS

TransPort PT878GC Panametrics Portable Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features

XMO2. Panametrics Smart Oxygen Analyzer. Applications. Features. bhge.com. An oxygen transmitter for use in:

Two-Wire In Situ Oxygen Analyzer (550 to 1400 C)

Mass Flow Controllers

TransPort PT878GC Panametrics Ultrasonic Portable Gas Flowmeter. GE Infrastructure Sensing. Features. Applications

AFC. SDPROC and AFC Analog Mass Flow Controller ANALOG MASS FLOW CONTROLLERS. Principles of Operation. Design Features

Over 20,000 Strain Gage Target flowmeters installed since 1952.

Autocalibration Systems For In Situ Oxygen Analyzers

Model 601CV. Mass Flow Controller. Product Features:

Flow Meters and Flow Controllers

RCD - Ultra-Rugged Differential Pressure Flowmeter

TELEDYNE HASTINGS INSTRUMENTS PRELIMINARY BULLETIN. Models HFM-D-301 & 305, HFC-D-303 & 307

SITRANS P measuring instruments for pressure

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

TFE-LINED VAREA-METER PVC-TUBE VAREA-METER

Two-Wire In Situ Oxygen Analyzer (550 to 1400 C)

Energy Management solutions for compressed air and industrial gases. vpinstruments.com

Thermatel Model TA2 Mass Flow Transmitter

HP/UHP Spring-Loaded Regulator

KMT. Thermal Mass Flowmeter. for compressed air and gases. Measuring range: Nm³/h Nm³/h

THERMAL MASS FLOW MEASUREMENT FOR GASES

TransPort PT878GC Panametrics Ultrasonic Portable Gas Flowmeter. GE Sensing. Applications. Features

Deep Submersible Level Transducer Series 300DS

C-Flow Coriolis Mass Flow Meters

Porter Lab & Analytical Products

Features. Main Voltage: Vdc. Input Control Signal: 0-5 Vdc or 4-20 madc (Sourcing) Monitor Output Voltage: 0-5 Vdc or 4-20 madc (Sourcing)

Torque Tube TB300 Digital Transmitters

High Purity & Ultra High Purity

Type N-10, N-11 Hazardous Area Non-incendive Transmitters

TEK-THERMAL 1700B. Thermal Mass Flowmeter. FLOW. Technology Solutions

High-performance submersible pressure transmitter For level measurement Model LH-10

Autocalibration Systems for In Situ Oxygen Analyzers

Micro Motion 7812 Fiscal Gas Density Meter

BUBBLER CONTROL SYSTEM

Bourdon Tube Pressure Gauges Ultra High Purity (UHP) Series Type

Z, Y, and X PURGE INDICATORS / CONTROLLERS

How to specify a product. Process Sensors and Mechanical Instruments

KMT. Thermal Mass Flow Meter. for Compressed Air and Gases. Measuring range: m3n/h m3 N

SLA5810/20/40 SLAMf10/20 Series

VIC offers a variety of Calibrated Gas Leaks

ALL-IN-ONE MINI THERMAL MASS FLOWMETER

BUBBLER CONTROL SYSTEM

SSL. Smart Valve Positioner.

3000 Series OPTIMASS Mass Flowmeter. Stainless Steel Hastelloy

3.0 Pressure Transmitter Selection

Level transmitter LT 100

CORI-FLOW PRECISION MASS FLOW METER / CONTROLLER FOR LIQUIDS AND GASES

Thermal Energy Flowmeter Model KEC. Application Range. Special Features

DTG - LCD Digital Temperature Gauge USER MANUAL

Micro Motion H-Series Hygienic Coriolis Flow and Density Meters

KDV HIGH ACCURACY GLASS TUBE ROTAMETER

EXPLOSION-PROOF PRESSURE, VACUUM, DIFFERENTIAL PRESSURE AND TEMPERATURE SWITCHES

The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions

LPS Product Guide. LPS Series Nitrogen Generators. N2-GEN LPS TM - Layup Protection System Copyrighted All Rights Reserved

DF-310E PROCESS ANALYSERS APPLICATIONS FEATURES

Electropneumatic Positioner Type 4763 Pneumatic Positioner Type 4765

9700 Transmitter Submersible hydrostatic level transmitter

Vortex flow sensor VA Di Ex-d with integrated, configurable transducer UVA in a flameproof enclosure for applications in explosive atmospheres

Series INTELLIGENT PRESSURE- AND LEVEL TRANSMITTERS For all industries. Description ALL STAINLESS DESIGN

Advance Optima -- High Performance Measurement Technology Oxygen Analyzer Module Magnos 16/17

KTE6000 / KTU6000 Series OEM pressure transmitters for industrial media

DM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

Plasma. Argon Production Helium Liquefaction Truck Loading Pure Gas Bottling

Analogue and Digital Mass Flow Meters and Controllers for Gases MASS-STREAM

X-Flow Mass Flow Controller 授权代理 : 北京品超思瑞科技学院公司

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

red-y compact series product information Battery Powered Thermal Mass Flow Meters for Gases

Thermatel Enhanced Model TA2 Thermal Mass Flow Meter

Varea-Meter Flowmeters. For Metering and Controlling Flows of Process Fluids

Model 4000 Pressure Controller

SERIES METAL TUBE VAREA-METER STRAIGHT THROUGH TYPE ROTAMETER

ASIC-Based Small Bore Submersible Level Transducer

ellison sensors international

SELECTION GUIDE SELECTION GUIDE. Pressure, Flow, Level & Temperature Products for Ultra-Clean Processing P R E C I S I O N S E N S O R S

Technical Datasheet. Pressure Transmitter: Analogue Series 387. Performance characteristics. Product applications. How can we help you?

Transcription:

Smart Ultra High Purity Thermal Gas Mass Flow Meter Features Measures mass flow directly, no seperate temperature or pressure inputs required Field adjustment of critical flow meter settings via on-board switches or Smart Interface (RS 232) Field validation of flow meter calibration Immersible sensor technology eliminates zero-drift problems associated with capillary-type mass flow meters Outstanding rangeability One-second response to changes in flow rate FM, CSA and EEx certified for hazardous areas CE approved 5 Harris Court, Bldg. L Monterey CA 93940 831/373-0200 800/866-0200 FAX: 831/373-4402 www.sierrainstruments.com 780S Ultra High Purity Series S Description ierra Instruments Series 780S UHP gas mass flow meters are the instruments of choice for gas distribution service in semiconductor fabs, pharmaceutical production and other ultra-clean processes. The Ultra High Purity meters are constructed of 316L electro-polished, stainless-steel with a 7-10 Ra or 20-25 Ra interior finish. The versatile microprocessor-based transmitter integrates the functions of flow-range adjustment, meter validation and diagnostics in either a probe-mounted or remote housing. Mass flow rate and totalized flow, as well as other configuration variables, are displayed on the meter s optional 2 x 12 LCD panel. The programmable transmitter is easily configured via RS-232 communication port and Sierra s Smart Interface software, or via the display and magnetic switches on the instrument panel. The Series 780S UHP Smart Electronics allow you to easily configure the following performance parameters: flow range, reset totalizer, alarm settings, time response, low flow cut-off and a calibration correction factor. The Series 780S UHP has a built-in flow conditioner which eliminates velocity-profile distortions caused by upstream disturbances. The meter is FM, CSA and CENELEC approved for operation in hazardous areas and is available with a variety of input-power, output-signal, mounting and packaging options. The information contained herein is subject to change without notice.

Dimensional Specifications 1 Through 6-inch 780S UHP (E2) Remote 780S UHP Specifications Remote Mounted with Junction Box (E4) H1 To center of pipe Per Customer Cable Length Requirement, 100 Feet Maximum NEMA 4X Remote Mounted with Junction Box (EN4) 0.70 (17.8) 3.93 (99.8) H2 To center of pipe Per Customer Cable Length Requirement, 100 Feet Maximum 780S UHP DIMENSIONS TUBING GENERAL BUTT WELD TRI-CLAMP VCR TUBE SIZE H1 H2 L1 L2 T1 T2 V1 V2 WALL.375 10.30 10.20 2.85 5.70 3.48 6.96.035 (9.5) (262) (259) (72.4) (144.8) (88.4) (176.8) (0.9).500 10.40 10.20 2.90 5.80 4.00 8.00.049 (12.7) (264) (259) (73.7) (147.3) (101.6) (203.2) (1.2) 1.00 9.10 9.20 2.50 5.00 3.00 6.00 4.72 9.44.065 (25.4) (231.1) (234) (63.5) (127) (76.2) (152.4) (119.9) (239.8) (1.7) 1.50 9.10 9.30 2.00 5.50 2.50 6.50.065 (38.1) (231.1) (131.3) (50.8) (139.7) (63.5) (165.1) (1.7) 2.00 10.90 10.80 2.50 7.00 3.00 8.00.065 (50.8) (276.9) (183.1) (63.5) (177.8) (76.2) (203.2) (1.7) 3.00 10.70 10.90 3.00 10.50 3.50 11.50.065 (76.2) (271.8) (178.1) (76.2) (266.7) (88.9) (292.1) (1.7) 4.00 10.70 10.90 4.00 14.00 4.62 15.25.083 (101.6) (271.8) (277) (101.6) (355.6) (116.8) (387.4) (2.1) 6.00 12.70 11.90 6.00 21.00.109 (152.4) (322.6) (302) (152.4) (533.4) (2.8) 3/8 & 1/2-inch 780S UHP Side View (EN2) 3/8 & 1/2-inch 780S UHP Front View (EN2) 0.70 (17.8) 0.90 (25.4) 1.97 (50.0) 3.93 (99.8) 2.38 (60.5) C L UPSTREAM STRAIGHT PIPE LENGTH REQUIREMENTS (1) AT 1 ATM Piping Condition 3/8 and 1/2-inch 780SUHP (2) 1 to 6-inch 780SUHP (4) Single 90 Elbow or T-Piece 1D 1D Reduction (4:1) 1D 3D Expansion (4:1) 3D 3D After Control Valve 3D 3D Two 90 Elbows (In Same Plane) 3D 3D Two 90 Elbows (Different Planes) 5D 5D Notes: (1) Number of diameters (D) of straight pipe required between upstream disturbance and the flow meter. (2) Requires 1D of straight pipe downstream of the flow meter. (3) Requires 3D of straight pipe downstream of the flow meter. (4) Requires 0D of straight pipe downstream of the flow meter. (5) Consult factory for pressure effect. L2 V2 L1 V1 3.93 (99.8) H2 All dimensions are inches. Millimeters are in parentheses. Certified drawings are available on request.

Performance Specifications Accuracy ± 2% of reading from 10 to 100% of calibrated range ± 0.5% of full scale below 10% of calibrated range Repeatability ± 0.2% of full scale Temperature Coefficient ± 0.02% of reading per F within ± 50 F of customer specified conditions ± 0.03% of reading per F within ± 50 F to 100 F of customer specified conditions ± 0.04% of reading per C within ± 25 C of customer specified conditions ± 0.06% of reading per C within ± 25 C to 50 C of customer specified conditions Pressure Coefficient.02% per psi for air, consult factory for other gases Response Time One second to 63% of final velocity value Operating Specifications Gases Argon, helium, hydrogen, nitrogen, oxygen (consult factory for other gases) Gas Pressure (2 limitations) Mechanical design pressure: Compression fittings: 500 psig (34.5 barg) Application gas pressure: See mass flow range tables for maximum application gas pressure Gas & Ambient Temperature Gas............... 15 F to 250 F (-10 C to 120 C) Ambient........... -5 F to 120 F (-20 C to 50 C) Leak Integrity 5 X 10-9 cc/sec of helium maximum Power Requirements 18 to 30 VDC (regulated), 625 ma maximum 100 to 240 VAC, 50/60 Hz, 15 watts maximum Output Signal Linear 0 5 VDC or 0-10 VDC proportional to mass flow rate, 1000 ohms minimum load resistance or Linear 4 20 ma proportional to mass flow rate, 700 ohms maximum resistance power supply dependent User-selectable..Active non-galvanically separated or passive galvanically separated (loop power rired) Alarms Hard contact user-adjustable high and low Dead band adjustable with Smart Interface software Relay ratings........ Maximum 400 VDC or VAC (peak), 140 ma Displays Alphanumeric 2 x 12 digit backlit LCD Adjustable variables via on-board switches (password protected) or with Smart Interface software Adjustable variables.. Full scale (50 to 100 %) Time Response (1 to 7 seconds) Correction factor setting (0.5 to 5) Zero and span Totalizer Seven digits (9,999,999) in engineering units Resettable by software, on-board switches or external magnet Viton, Neoprene, Kalrez, and Teflon are registered trademarks of Dupont. Windows and Excel are registered trademark of Microsoft. Software Smart Interface Windows -based software Minimum 8 MB of RAM, preferred 16 MB of RAM RS 232 communication Additional features.. Alarm dead band adjustment Zero cut-off adjustment Linearization adjustment Save / Load configurations Flow meter validation Physical Specifications Wetted Materials 316L stainless steel UHP............... 7 to 10 Ra internal finish HP................. 20 to 25 Ra internal finish Enclosure Hazardous-Area Location Enclosure (IP67) or NEMA 4X (IP65) Both are powder-coated cast aluminum Electrical Connection Two 3/4 inch NPT... Hazardous-Area Location Enclosure (IP67) One 1/2 inch NPT... NEMA 4X Enclosure (IP65) Certifications CE (All enclosures) CSA (Explosion proof for Class I, Division 1, Groups B, C, D) EEx (EEx d IIC T6 T2) Cenelec FM (Explosion proof for Class I, Division 1, Groups B, C, D) Hazardous-Area Location Enclosures must be specified for CSA, EEx or FM approved products. Mass Flow Ranges EEx approved meters maximum velocities and flow rates are 50% of standard values shown in charts 780S-UHP-Air - Gas Code 0 standard accuracy 3/8" 0.00043 20,000 9 14 120 standard accuracy 1/2" 0.00093 20,000 19 29 120 standard accuracy 1" 0.00410 20,000 82 129 120 standard accuracy 1-1/2" 0.01020 20,000 204 322 120 standard accuracy 2" 0.01910 20,000 382 602 120 standard accuracy 3" 0.04490 20,000 898 1416 120 standard accuracy 4" 0.08020 20,000 1604 2530 120 standard accuracy 6" 0.18235 20,000 3647 5752 120 780S-UHP-Argon - Gas Code 1 standard accuracy 3/8" 0.00043 28,000 12 19 120 standard accuracy 1/2" 0.00093 28,000 26 41 120 standard accuracy 1" 0.00410 28,000 115 181 120 standard accuracy 1-1/2" 0.01020 28,000 286 450 120 standard accuracy 2" 0.01910 28,000 535 843 120 standard accuracy 3" 0.04490 28,000 1257 1983 120 standard accuracy 4" 0.08020 28,000 2246 3542 120 standard accuracy 6" 0.18235 28,000 5106 8052 120 780S-UHP-CO 2 - Gas Code 2 standard accuracy 3/8" 0.00043 19,800 9 13 120 standard accuracy 1/2" 0.00093 19,800 18 29 120 standard accuracy 1" 0.00410 19,800 81 128 120 standard accuracy 1-1/2" 0.01020 19,800 202 319 120 standard accuracy 2" 0.01910 19,800 378 596 120 standard accuracy 3" 0.04490 19,800 889 1402 120 standard accuracy 4" 0.08020 19,800 1588 2504 120 standard accuracy 6" 0.18235 19,800 3611 5694 120

Mass Flow Ranges EEx approved meters maximum velocities and flow rates are 50% of standard values shown in charts Pressure Drop for 780S UHP 780S-UHP-Helium - Gas Code 3 standard accuracy 3/8" 0.00043 12,400 5 8 120 standard accuracy 1/2" 0.00093 12,400 12 18 120 standard accuracy 1" 0.00410 12,400 51 80 120 standard accuracy 1-1/2" 0.01020 12,400 126 199 120 standard accuracy 2" 0.01910 12,400 237 374 120 standard accuracy 3" 0.04490 12,400 557 878 120 standard accuracy 4" 0.08020 12,400 994 1568 120 standard accuracy 6" 0.18235 12,400 2261 3566 120 780S-UHP-Hydrogen - Gas Code 6 standard accuracy 3/8" 0.00043 9,600 9 13 135 standard accuracy 1/2" 0.00093 9,600 18 29 135 standard accuracy 1" 0.00410 9,600 98 128 135 standard accuracy 1-1/2" 0.01020 9,600 100 155 135 standard accuracy 2" 0.01910 5,235 100 158 135 standard accuracy 3" 0.04490 2,227 100 158 135 standard accuracy 4" 0.08020 1,246 100 158 135 standard accuracy 6" 0.18235 548 100 158 135 See chart below for flows greater than 100 SCFM standard accuracy 2" 0.01910 9,600 188 289 85 standard accuracy 3" 0.04490 5,568 250 395 85 standard accuracy 4" 0.08020 3,117 250 395 85 standard accuracy 6" 0.18235 1,370 250 395 85 See chart below for flows greater than 250 SCFM standard accuracy 3" 0.04490 8,908 400 632 ambient standard accuracy 4" 0.08020 4,988 400 632 ambient standard accuracy 6" 0.18235 2,194 400 632 ambient 780S-UHP-Nitrogen - Gas Code 10 standard accuracy 3/8" 0.00043 19,800 9 13 120 standard accuracy 1/2" 0.00093 19,800 18 29 120 standard accuracy 1" 0.00410 19,800 81 128 120 standard accuracy 1-1/2" 0.01020 19,800 202 319 120 standard accuracy 2" 0.01910 19,800 378 596 120 standard accuracy 3" 0.04490 19,800 889 1402 120 standard accuracy 4" 0.08020 19,800 1588 2504 120 standard accuracy 6" 0.18235 19,800 3611 5694 120 780S-UHP-Oxygen - Gas Code 11 4% correlation 3/8" 0.00043 19,800 9 13 120 4% correlation 1/2" 0.00093 19,800 18 29 120 4% correlation 1" 0.00410 19,800 81 128 120 4% correlation 1-1/2" 0.01020 19,800 202 319 120 4% correlation 2" 0.01910 19,800 378 596 120 4% correlation 3" 0.04490 19,800 889 1402 120 4% correlation 4" 0.08020 19,800 1588 2504 120 4% correlation 6" 0.18235 19,800 3611 5694 120

Ordering the Model 780S UHP 780S PARENT MODEL NUMBER 780S Ultra High Purity In-Line Mass Flow Meter with built-in flow conditioner AGENCY APPROVALS NAA Non-Agency Approved Meter CSA Explosion Proof for Class I, Division 1, Groups B, C, D EEx EEx d IIC T6 T2 Cenelec FM Explosion Proof for Class I, Division 1, Groups B, C, D RA FINISH HP UHP 20 25 Ra Internal Finish 7 10 Ra Internal Finish MOUNTING BW1 3/8-inch Tube O.D. Butt Weld Prep VCR1 3/8-inch Tube O.D. Female VCR Fitting BW2 1/2-inch Tube O.D. Butt Weld Prep VCR2 1/2-inch Tube O.D. Female VCR Fitting BW4 1-inch Tube O.D. Butt Weld Prep VCR4 1-inch Tube O.D. Male VCR Fitting TR4 1-inch Tube O.D. Tri-Clamp Connection BW5 1.5-inch Tube O.D. Butt Weld Prep TR5 1.5-inch Tube O.D. Tri-Clamp Connection BW6 2-inch Tube O.D. Butt Weld Prep TR6 2-inch Tube O.D. Tri-Clamp Connection BW7 3-inch Tube O.D. Butt Weld Prep TR7 3-inch Tube O.D. Tri-Clamp Connection BW8 4-inch Tube O.D. Butt Weld Prep TR8 4-inch Tube O.D. Tri-Clamp Connection BW9 6-inch Tube O.D. Butt Weld Prep (Available in HP Finish Only) ENCLOSURES E2 Hazardous-Area Location Enclosure E3(ft) Remote Hazardous-Area Location Enclosure (Only with EEx Meters) E4(ft) Remote Hazardous-Area Location Enclosure with Junction Box EN2 NEMA 4X EN4(ft) Remote NEMA 4X with Junction Box Specify Cable Length in Parentheses, Maximum 200 feet (60 m), Length in Feet using 5 ft. increments to 20 ft., 10 ft. increments to 200 ft. INPUT POWER P2 19 30 VDC P3 100 240 VAC (Not Available on EN Enclosures) OUTPUT SIGNAL V1 0 5 VDC, Linear V3 0 10 VDC, Linear V4 4 20 ma, Linear DISPLAY NR DD No Readout Digital Display GAS CODE 0 Air 1 Argon 2 CO 2 6 Helium 4 Hydrogen 10 Nitrogen 11 Oxygen (Correlation) 99 Other OPTION 1 PT CC NC Pressure Test Certificate Certificate of Conformance NACE Certificate ACCESSORIES (CONSULT FACTORY)

5 Harris Court, Building L Monterey, California (800) 866-0200 (831) 373-0200 Fax (831) 373-4402 www.sierrainstruments.com SIERRA INSTRUMENTS b.v. Bijlmansweid 2 1934 RE Egmond a/d Hoef The Netherlands +31 (0) 72 5071400 Fax +31 (0) 72 5071401 780S UHP 04/03