Contents. Introduction...1 About Breeze... 1 Breeze Overlay... 2 Breeze Mattress Replacement... 2 Breeze Pump... 4 Controls and Indicators...

Similar documents
User Manual. 10. Dimensions and Ordering Codes. Integrity Alternating Pressure Mattress System. Alternating Pressure Mattress Systems

Diamond 8 Plus. Alternating + Micro Low Air Loss Pressure Relief System. User Manual. Distributed by: Quart Healthcare Inc.

Air Plus User Manual

Pegasus Aircare Mattress Overlay System Models 2200 and 2201

USER MANUAL. AltaDyne XT Model A AltaDyne XD Model A Alternating Pressure / Low Air Loss Replacement Mattress System

NIMBUS range. with people in mind

LOGIC RANGE AUTOMATIC PRESSURE

Operation Manual. H & R Healthcare 1750 Oak Street Lakewood, NJ Phone: Fax:

NIMBUS 4 NIMBUS PROFESSIONAL

Instruction Manual for Configura Cushionair Portable Pump

Alternating Pressure / Low Air Loss Mattress System

ALPHAXCELL. Active pressure relieving mattress overlay system for medium risk patients in all environments

APH166 Morpheus Air USER MANUAL. Apollo Healthcare Technologies Ltd. Holme Street, Liversedge, West Yorkshire, WF15 6JF.

LOGIC RANGE AUTOMATIC PRESSURE REDISTRIBUTING SySTEMS

Med Aire Alternating Pressure Pump and Pad System

NIMBUS 3 NIMBUS 3 PROFESSIONAL

Paradise Pump Series Operator s Manual

User Manual DIRECTHEALTHCARESERVICES.CO.UK

User Manual DIRECTHEALTHCARESERVICES.CO.UK

User Manual DIRECTHEALTHCARESERVICES.CO.UK

Lateral Turning System. User Guide.

Operator s Manual. Dynamic Low-Air-Loss Therapy with Alternating Pressure

MA90 Series Mattresses. MA95 Series Mattresses

AKRON CHILDS TILT TABLE

SALISBURY ACTIVE OVERLAY SYSTEM

RIK Fluid Overlay INSTRUCTIONS FOR USE

PRESSUREGUARD APM OWNER S MANUAL. PressureGuard APM Bariatric. Span-America Medical Systems, Inc. Greenville, SC

Key Product Features. Primary Use: Aggressive Treatment of Pressure Ulcers

LIFECOMFORT ACTIVE AIR

Use this key to determine which sections of this Product Manual apply to your job.

Domus series. Pressure Redistribution System

User manual STARLOCK. Careways International - Innovation Quality Performance

(DynaLaL III) Dynamic True Low Air Loss Mattress Replacement System

PRESSURE REDISTRIBUTION SYSTEM. with people in mind

Panacea AIR PRO MATTRESS. Owner s Manual. Please keep and refer to this Owner s Manual.

UK RBF Bath buddy instruction 16pp 21/9/07 09:07 Page 1. Bath-Buddy / Bathmate Instruction Book

User manual. ZX trolley.

User Manual. Version 1.2 July 2015 Pg. 1

AltaDyne AutoFloat. Alternating Pressure Management Plus. Model # Model # OPERATORS MANUAL

User Guide Antidecubitus systems EURO BASIC

SELECT SERIES LS200 ALTERNATING PRESSURE / LOW AIR LOSS MATTRESS SYSTEM

SELECT SERIES LS300 ALTERNATING PRESSURE / LOW AIR LOSS MATTRESS SYSTEM

770000S CLINICAL MAX LOW AIR LOSS WITH ALTERNATING PRESSURE SYSTEM USER MANUAL

User Manual DIRECTHEALTHCARESERVICES.CO.UK

Flat Fold Highchair INSTRUCTION MANUAL. Designed and manufactured to BS EN 14988: 2012 IMPORTANT:

Theatre Control Panel. Instructions for Use. January 2017 ASF-29 (1)

Actively supporting your health.

POWERPRESS UNIT. User Manual. Gradient Pneumatic Sequential Compressor. Neomedic

Autom ate d t u r n i n g at yo u r f i n g e r t i ps

FLOWTRON HYDROVEN 3. User Manual. Intermittent Pneumatic Compression System

Joerns Healthcare. transforming wound management. User-Service Manual TriLine Support Surface. To avoid injury, read user s manual before using.

MA60 Series. MA60 Alternating Pressure System. MA65 Alternating Pressure On-Demand Low Air Loss System. Owner s Operator and Maintenance Manual

DYNAMIC COMPRESSION THERAPY

SC505 Sof Care Inflator. Operating Instructions and Service Manual

User Manual. This manual MUST be given to the user of the product. BEFORE using this product, read this manual and save for future reference.

Instructions for Use

PressureGuard APM 2 and PressureGuard APM 2 Safety Supreme

Leglifter. user instructions. Simple solutions for everyday independence

450P- RV AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

Continuing Education classes during the month of June will be dedicated to the following topic matter:

450P AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

PETERSEN 161-SERIES HIGH PRESSURE LIFTING AIR BAGS OPERATING INSTRUCTIONS WARNING!

General User/ Safety Guide ROYAL/ ROYAL EXTRA REPLACEMENT SYSTEM

User Manual soft air wds

Pressure Regulator. Instructions for Use

Instructions for Use. OptiLife Nasal Lab Mask

GAS BBQ 4 burner. instructions for. model no: BBQ10

User Manual. soft air simplex wds. Health. Security. Independence. Pressure ulcer prevention and treatment-system Assembly and Operation instructions

Bath Buddy / Bathmate Instruction Book

Oxygen Dialflow Meter. Instructions for Use

LYMPHA PRESS MANUFACTURED BY MEGO AFEK IMPORTED BY LYMPHA PRESS USA, Ltd. USERS MANUAL LYMPHA PRESS MODEL 201-M

Regalia Oxygen Concentrator

Seating Systems. The Company. Park House

Intermittent Pneumatic Compression System

OPERATOR'S MANUAL. TOTALIFT - II LATERAL TRANSFER / TRANSPORT CHAIR Model No R02 AN

Precioso series 2. Prevention and therapy for everybody, everyday NURSING-CARE HEALTHCARE

User-Service Manual Joerns Support Surface FlapCair. To avoid injury, read user s manual before using.

Nanofold Highchair Instruction Manual

DOC PCB901 Rotating Half Rail Instructions REV 001

Digital Melting Point Apparatus

General User/ Safety Guide ROYAL/ ROYAL EXTRA REPLACEMENT SYSTEM

EasyFit SilkGel Full Face Mask

ORB-400 BUBBLE/HAZE MACHINE. Item ref: UK User Manual

POWER ASSISTED BICYCLES OWNERS MANUAL

SUPREME 2 OVERLAY SYSTEM

MODEL NUMBER: PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank

BABY ROCKER WITH TOY BAR

Safety Powder Spray Systems

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:

CONTENTS SPECIFICATIONS GENERAL INFORMATION RECOMMENDED USE OPERATING PRINCIPLE TIPS ON TAKING YOUR BLOOD PRESSURE 3-4 BATTERY INSTALLATION

Cascade Patient Transfer Lift System Safe Operation & Daily Maintenance Instructions

The Univentor 1250 Anaesthesia Unit

Standing Slings Instruction & Safety Manual

IsoAir. Operation/Maintenance Manual. Stryker Customer Service: /12 AO-SM-70-C REV 4.00

LikoStretch Product Description. Instruction Guide

Oxygen Dialflow Meter. Instructions for Use

CircuFlow Quick Setup Guide

EasyFit Lite Nasal Mask, Silicone. Nasal Mask. EasyFit Lite Nasal Mask. Device Description and Instructions for Use. Caution:

Oxygen concentrators. A user guide.

Transcription:

English

Contents Introduction........................................................1 About Breeze................................................... 1 Breeze Overlay................................................. 2 Breeze Mattress Replacement..................................... 2 Breeze Pump................................................... 4 Controls and Indicators........................................... 4 Clinical Applications.................................................6 Indications..................................................... 6 Contraindications................................................ 6 Patient In Chair................................................. 6 Operation..........................................................7 Preparing the Pump and Mattress System for Use...................... 7 CPR Facility.......................................................10 Patient Transport..................................................11 Controls and Indicators.............................................12 Power Button.................................................. 12 Comfort Adjust................................................. 12 Mode Button.................................................. 12 Low Pressure.................................................. 13 Power Fail.................................................... 13 Turn Valves................................................... 13 Decontamination...................................................14 During Use.................................................... 14 Troubleshooting Guide..............................................15 Warranty and Service...............................................16 Technical Data.....................................................17 Cover options and features....................................... 19 (i)

(ii)

General Safety Before you connect the system pump to a mains socket, read carefully all the installation instructions in Section 3 - Operation. The system has been designed to comply with regulatory safety standards including EN60601-1. UL2601-1 & CAN/CSA C22.2 No 601-1 Safety Warnings The cover of this product is vapour permeable but not air permeable and may present a suffocation risk. It is the responsibility of the care giver to ensure that the user can use this product safely. Electrical equipment may be hazardous if misused. The pump's case back should only be removed by authorised technical personnel. Do not use the pump in the presence of flammable gases such as anaesthetic agents. Whilst patient is unattended, bed side rails should be used in line with local clinical practice. If bed side rails are used, no gap wide enough to entrap a patient's head or body should exist when the mattress is secured. Otherwise death or serious injury may occur. Due to the inherently lower flame retardancy of the high performance event 1 fabric, it is NOT suitable for use in the homecare environment. Precautions For your own safety and the safety of the equipment, always take the following precautions: Keep the pump away from sources of liquids and do not immerse in water. Do not expose the system, especially the mattress, to naked flames, such as cigarettes etc. Do not store the system in direct sunlight. Switch off the electrical supply to the pump by disconnecting the pump from the mains socket before cleaning and inspection. Do not use hypercarbonate or phenolic based cleaning solutions. Ensure the system is clean and dry prior to storage. Never use sharp objects or electrically heated under blankets on or under the system. Store the pump and mattress in the protective bags supplied. Only the pump and mattress combination as indicated by Huntleigh Healthcare should be used. The correct function of the product cannot be guaranteed if the incorrect pump/mattress combinations are used. 1. event is a registered trademark of BHA Technologies Inc. (iii)

(iv)

1. Introduction About Breeze The Breeze low air loss systems are one of the most advanced Pressure Area Management Systems manufactured by Huntleigh Healthcare for the prevention and management of pressure sores. Breeze is a Low Air Loss overlay or mattress replacement system, which is easy to install and use with either standard hospital beds or divan beds within the home. Beds can be adjusted or gatched without impairing the pressure reducing performance of the Breeze system. The system comprises the Breeze pump and either an overlay or mattress replacement, which together assist in achieving effective pressure area care, with correct patient support and maximum comfort. The Breeze pump is lightweight and compact with controls which allow comfort adjustment to suit the individual patient. The pump provides three modes of operation: Static Mode provides continuous low pressure. Pulsate Mode combines continuous low pressure with a periodic pulsation of the support surface. Autofirm Mode provides a firm support surface to facilitate nursing procedures and/or patient transfer. The Breeze mattresses are made up of 17 ventilated cells which form a constant low pressure support surface. The cells form three zones of pressure reduction: Eight torso section cells provide effective support under the heaviest body area. Three head section cells have even lower cell pressures. Six leg section cells have the lowest cell pressures. Each cell is capable of being individually deflated by the use of an inline turn valve. The Breeze mattress replacement has an additional single air-filled sub-mattress which acts as a replacement for a standard bed mattress. 1

Breeze Overlay The Breeze cover is water resistant and vapour permeable to enhance patient comfort whilst protecting the cells from ingress of contaminants. The cover is simple to clean in situ, but may easily be removed for laundering or autoclaving, preventing cross contamination. In the event of cardiac arrest both the overlay and the mattress replacement can be easily deflated in approximately 10 seconds to allow cardiac resuscitation procedure to be performed. Cover Head End 17 Static Ventilated Cells Holding Strap Securing Apron Foot End Inline Turn Valve Breeze Mattress Replacement Cover Head End 17 Static Ventilated Cells Base Cover Foot End Single Tubing Connector & CPR Release Inline Turn Valve 2

Г Cells Turn Valves Seventeen polyurethane (PU) cells approximately 125mm (5 ) high providing support to the patient. Incorporated into the manifold of the six leg cells are inline turn valves. These valves enable each cell to be deflated individually. Before setting up the system ensure that the Turn Valves are in the correct position according to the type of therapy required. Tube Set Tube Connector and CPR Release Cover Air Cell Sub-Mattress (Mattress Replacement Only) Made from materials which reduce the risk of accidental kinking of the tubing. Located at the pump end of the tubing set is a specially designed snap-lock connector. This particular design helps prevent accidental disconnection of the mattress from the pump. Releasing the connector allows the air to escape from the cells in approximately 10 seconds to facilitate CPR. The mattress is totally enclosed in a double zipped cover. The top and sides of the cover are constructed from a two-way stretch and water resistant material, which is vapour permeable for maximum patient comfort. The base of the cover is constructed from a tough abrasion resistant material and is fitted with bed attachment straps and sheet clips. A 75 mm (3 ) thick sub-mattress made of a single airfilled cell. 3

Breeze Pump Power Button Power Lights Mode Button and Indicator Lights Comfort Adjust Controls and Indicator Lights 8 7 6 5 4 3 2 1 Mode! Low Pressure Alarm Light Mounting Hooks Controls and Indicators The pump has a tough outer case, with non-slip feet situated on the back. As an alternative to laying the pump on its back on a firm surface, the mounting hooks allow easy positioning of the pump on the bed frame. Power Button When the pump is connected to a suitable power supply, the orange Standby light illuminates. When the Power button is pressed, the green On light illuminates. Power Fail Alarm This indicator will flash and an audible warning will sound in the case of power failure. Mode This control allows the user to switch between the three modes below. Autofirm provides a firmer surface for patient transfer on and off the bed and allows for easier nursing procedures. 4

Static provides a constant low pressure support surface. Pulsate provides a low pressure support surface with a regular pulse which may stimulate patient movement. Low Pressure Alarm Light! Situated on the front of the pump, the red low pressure alarm light illuminates if the pump blower fails and cannot deliver the required pressure. Comfort Adjust Control Located on the front of the pump, this control provides the means for adjusting the pressure inside the mattress. 5

2. Clinical Applications A risk assessment tool combined with clinical judgement should be used when determining a patient s level of risk of developing pressure ulcers. Patient risk assessment should be an ongoing process as changes in the patient s condition may increase or decrease their risk level. Г Indications Contraindications Patient In Chair The Breeze mattress system is indicated for patients up to 140 kg (308 lb.) and is suitable for the prevention and management of all grades of pressure ulcers. The Breeze system should not be used for patients with unstable spinal fractures. In the case of patients with other unstable fractures, where a moving surface can be harmful, advice should be obtained from the appropriate physician before using the Breeze system. If the patient will be sitting in a chair for any period of time, it is strongly recommended that a pressure reducing or pressure relieving seat cushion is used. The Breeze mattresses are an aid to the prevention and management of pressure ulcers. If there is no improvement in the patient s condition, clinical advice should be sought. The above are guidelines only and should not replace clinical judgement or experience. 6

3. Operation Preparing the Pump and Mattress System for Use The system is very simple to set up using the following guidelines. 1. Remove the system from its packaging. 2. Plug the pump power cord into the electrical outlet; the Standby light will illuminate. 3. The pump should be placed feet down on any convenient surface or alternatively suspended from the bed foot rail by means of the swing out hooks. Breeze Overlay If you have the Breeze Overlay mattress it should be installed as follows: 1. Place the overlay mattress on top of the base mattress, with the tube-set located near the foot end of the bed. Caution Do not use the mattress overlay directly on the bed frame. 2. Secure the overlay to the base mattress by securing the apron under the foot end of the mattress and the corner straps to the head end. Breeze Mattress Replacement To Complete the Mattress Installation If you have the Breeze Mattress Replacement it should be installed as follows: 1. Remove the existing mattress from the bed frame and check that there are no protruding bed springs or sharp objects on the bed frame surface. 2. Unroll the mattress onto the bed frame and ensure that the tube-set is located near the foot end of the bed. The cells of the mattress must be uppermost. 3. Attach the mattress to the bed frame using the fastener straps. 1. Ensure the protective cover over the cell assembly is fixed in position. This will reduce the risk of the cell assembly becoming contaminated. 7

2. Connect air feed tubes to the pump unit, ensuring that the tubes are not kinked or excessively twisted. Push the connector in until it clicks. Г 3. Press the Power On button; the On indicator will illuminate and the pump blower will start. 4. Allow approximately three minutes for the mattress to inflate fully. Lift the cover and ensure the cells are fully inflated and in line. For the mattress replacement, check that the static pad is level. Refit cover. 5. Place a bed sheet over the mattress and tuck in loosely without wrinkles. The 6 leg cells can be individually deflated for medical procedures, refer to Turn Valves on page 13. This product can be used with a pillow to enhance comfort. Ensure the head does not develop pressure damage. 8

WARNING Ensure that the patient is not bottoming out by sliding a hand between the inflated top cells, and above the air-filled sub-mattress/bed mattress underneath the patient s heaviest point; e.g. buttocks. The correct amount of lift is achieved when two fingers can be easily slid underneath. If only the flat hand can be slid under, then more support is required. Increase the comfort adjust control slightly, wait 1 minute and check again, adjusting if necessary. If more than two fingers can be slid underneath, i.e. three fingers depth, there is too much support. Decrease the comfort adjust control, wait 1 minute and check again, adjusting if necessary. If the patient s position changes, recheck the lift as above. Alignment of bed frame, bedside rails and mattress should leave no gap wide enough to entrap a patient s head or body. Care should be exercised to prevent occurrence of gaps by compression or movement of the mattress. Death or serious injury may result. 9

4. CPR Facility IMPORTANT In the event of cardiac arrest, depress the red release catch on the tubeset/pump connector, and at the same time pull the tubeset out and away from the pump. Г Located on the left hand side of the pump is a red release catch marked with an arrow. In the event of cardiac arrest, depress this catch and pull the tubeset from the pump. Deflation will occur in approximately 10 seconds. To reinflate the mattress, reconnect the tubeset to the pump. Ensure that the pump is connected to the power supply and switched on. 10

5. Patient Transport Г The patient may be transported on the Breeze Mattress Replacement only, by disconnecting the pump from the mains power supply. The air-filled sub-mattress will provide temporary support for up to six hours. Do not disconnect the tubeset from the pump, as this deflates the air-filled sub-mattress. If the patient is lying on the mattress, do not remove the mattress from the bed. 11

6. Controls and Indicators Г Power Button Comfort Adjust This is situated on the front of the pump. When power is supplied to the pump unit, the orange Standby indicator is illuminated. Pressing the Power Button will activate the pump, the standby indicator will extinguish. The green On indicator will be illuminated. The default condition at switch-on is Static mode, Comfort level 4. These controls adjust the amount of air flowing to the cells and thus their firmness. The level can be seen represented on the scale marked 1-8 with 1 being the lowest pressure setting and 8 being the highest setting. To increase the firmness of the cells push the To decrease the firmness of the cells push the See Section 3 for selecting the correct setting. arrow. arrow. A lock-out facility prevents accidental alterations being made to the comfort adjust, operation mode and the operation of the pump. This lockout facility is disabled by pressing both the and together, allowing the desired adjustment(s) to be made. Lock-out is activated when the On light is flashing, and deactivated when the On light is continually illuminated. Lock-out reactivates itself after five minutes from last unlock. Mode Button Press this button to switch between modes. The Mode light flashes for a few seconds before the selected mode is activated to allow you to scroll between modes. Once a mode is activated, the light becomes steady. Autofirm - mode inflates the cells to their maximum pressure to provide a firm and stable surface to facilitate nursing procedures and/or patient transfer. Г After 10 minutes the system will revert to static mode at the previously set comfort level. A one minute alarm will give warning of this change. Pressing the Mode button twice more will reset Autofirm for a further 10 minutes. Static - mode is the normal operating mode of the system and provides constant low pressure. 12

Low Pressure! Power Fail Turn Valves Pulsate - mode results in a small fall and then rise in cell pressure approximately every 30 seconds. Some users may find that this further enhances their comfort level. This light illuminates if the pump blower fails and cannot deliver the required pressure. An audible alarm will also be activated. Refer to the Troubleshooting section. In the event of a power failure, the red Power Fail indicator will be illuminated. An audible alarm will be activated. To mute the alarm, press the Power button. To reset the alarm, restore power and press the Power button. Refer to the Troubleshooting section. Each of the six leg cells is capable of being individually deflated by the use of an Inline Turn Valve. Each valve has two positions: Open - Allows the cell to be inflated. Г Turn the Valve so that it points toward the head end of the mattress. Closed - Deflates the cell. Г Turn the Valve so that it points toward the foot end of the mattress. INFLATED DEFLATED Г Before setting up the system ensure that the Turn Valves are in the correct position according to the type of therapy required. 13

7. Decontamination The following guidelines have been established in accordance with good infection control practice. Should you have any questions regarding cleaning or if you require further information please contact our service centre. Caution Gloves and protective clothing should always be worn when carrying out decontamination procedures. During Use WARNING Switch off the electrical supply to the pump and disconnect the power cord from the mains supply before cleaning and inspection. To clean To disinfect Laundering Further Information The mattress, pump, tube-set and other ancillary parts should be cleaned weekly and in between each patient use using a disposable cloth soaked in mild detergent and warm water. Do not use abrasive compounds or pads. The user should avoid immersing electrical parts in water during the cleaning process. All parts can be wiped down with sodium hypochlorite or NaDCC solution at 1000ppm of available chlorine following the cleaning procedure. Outside the UK use disinfectant recommended in local hospital infection control guidelines. Do not use Phenol or Quarternary Ammonium Compound (QAC) based cleaning solutions as these will damage the surface coating. The mattress top covers can be easily unzipped for complete removal to allow laundering at 65 C for 10 minutes or 80 C for 3 minutes to achieve thermal disinfection. This complies with HSG(95) 18 Hospital Laundry arrangements for used and infected linen (UK) 1995. DO NOT TUMBLE DRY COVERS ABOVE 50 C. For further detailed decontamination guidance, consult Huntleigh Healthcare Infection Control Procedures. Policy Guidelines. 14

8. Troubleshooting Guide WARNING Electrical equipment may be hazardous if misused. The pump s case back should only be removed by authorized technical personnel. There are no user-serviceable parts. Problem Possible Cause Action Mattress not inflating. 1. Tubes kinked. Check 2. Pump not switched on. Check 3. No pump output. 4. Punctured cell or leakage from T connector Check - See Pump not operating below Check 5. Tubes or connector notcorrectly fitted. Check Leg Cell(s) Not Inflated Inline Turn Valve in Closed Position Check. Consistent Low Pressure Alarm. Pump blower not operating. Call Service Engineer for maintenance. The Power Fail indicators (audible and visual) are active. The Power Fail indicator remains constantly illuminated but there is no audible alarm. Pump makes a lot of abnormal noise and/or is causing lot of vibration. Pump not operating. Standby light not lit. 1. A Mains power failure has occurred. 2. The power cord has been removed from the wall socket. There has been a power failure but power has been restored. System damaged. 1. Pump is not switched on. 2. Plug not inserted correctly. 3. Technical failure. No power to pump. Check. Check. Press Power button to activate pump. Call Service Engineer for maintenance. Press Power button. Check Call Service Engineer for maintenance. Check unit plugged in and fuse in plug is OK. Fuse(s) inside unit blown. Call Service Engineer to replace fuse. Г Ensure pump alarms are reset by operating the Power button after the fault has been corrected. 15

9. Warranty and Service Huntleigh Healthcare s standard terms and conditions apply to all sales. A copy is available on request. These contain full details of warranty terms and do not limit the statutory right of the consumer. For service, maintenance and any questions regarding this, or any other Huntleigh Healthcare product, please contact: Huntleigh Healthcare Ltd 310-312 Dallow Road Luton Bedfordshire, LU1 1TD Tel : +44 (0) 1582 413104 Fax : +44 (0) 1582 459100 or your local distributor. 16

10. Technical Data Pump Model No: LAL001 Size: 305 x 186 x 135 mm (12 x 7.5 x 5.5 in.) Weight: 4 kgs (9 lbs) Rated Voltage: 230 V Rated Frequency: 50 Hz Rated Input Power: 460 V A Complies with: BS EN 60601-1 Fuse ratings: Plug: 5A to BS1362 Display board: 500 ma Filter board: 2 x 5 A Protection Class: Type BF Class I. Not protected against entry of water. Mode of operation: Continuous Equipment Symbols: Alternating Current! Warning SN: Serial number Environmental Conditions Operating Temperature range: +10 C to +40 C Relative Humidity: 30% to 75% Atmospheric Pressure: Storage Storage temperature range: Relative humidity: Atmospheric Pressure: Environmental Protection: 700hPa to 1060 hpa -40 C to +70 C 10% to 100% (non-condensing) 500 hpa to 1060 hpa Please dispose of this unit in accordance with local regulations. 17

Mattress Overlay Size: Inflated Mattress Height: Cell Material: Mattress Replacement Size: Inflated Top Cell Height: Inflated Mattress Height: Cell Material: Air-filled sub-mattress size: 642001OLDAR (Standard Cover) 642001OLADV (Advantex Cover) 642001OLEVE (event Cover) 2090 x 866 mm (82 x 34 inches) 133 mm (5 inches) Polyurethane 624001DAR (Standard Cover) 624001ADV (Advantex Cover) 624001EVE (event Cover) 2090 x 866 mm (82 x 34 inches) 133 mm (5 inches) 203 mm (8 inches) Polyurethane 2032 x 838 x 63.5 mm (80 x 33 x 3 inches) 18

Cover options and features Feature Standard Cover Advantex event Fabric * Moisture vapour permeable Yes Yes 12 x higher Air permeable No No Yes Low friction Yes 18% lower 20% lower Water resistant / repellent Yes Yes Yes Infection Control Bacteriostatic, fungistatic, antimicrobial Bacteriostatic, fungistatic, antimicrobial INERT MATERIAL does not support bacterial growth Fire retardant BS 7175: 0,1 & 5 BS 7175: 0,1 & 5 BS EN ISO 12952-1 ONLY 2 way stretch Yes Some No Cleaning conditions Removable cover, washable at 80 C Removable cover, washable at 80 C Removable cover, washable at 80 C Life span 50 Wash Cycles 50 Wash Cycles 15 Wash Cycles Application area Acute and Homecare Acute and Homecare Acute ONLY * Due to the inherently lower flame retardancy of the high performance event fabric, it is NOT suitable for use in the homecare environment. Cleaning Symbols Wash at 176 F (80 C) Do not iron Do not use phenol or QAC based cleaning solutions Do not tumble dry above 50 Wipe surface with damp cloth Use solution diluted to 1000 ppm 19

20