A CONCEPT OF MEAN ALVEOLAR AIR AND THE VENTI- LATION -BLOODFLOW RELATIONSHIPS DURING PULMONARY GAS EXCHANGE

Similar documents
Lung Volumes and Capacities

PICU Resident Self-Study Tutorial The Basic Physics of Oxygen Transport. I was told that there would be no math!

UNIQUE CHARACTERISTICS OF THE PULMONARY CIRCULATION THE PULMONARY CIRCULATION MUST, AT ALL TIMES, ACCEPT THE ENTIRE CARDIAC OUTPUT

Douglas and Haldane(2) has shown that the oxygen determinations. since it forms the basis of the "Coefficient of Utilisation" (Krrogh) and

ALVEOLAR - BLOOD GAS EXCHANGE 1

Collin County Community College. Lung Physiology

RESPIRATORY GAS EXCHANGE

I Physical Principles of Gas Exchange

Section Two Diffusion of gases

RESPIRATORY REGULATION DURING EXERCISE

Respiration (revised 2006) Pulmonary Mechanics

Respiratory physiology II.

Unit II Problem 4 Physiology: Diffusion of Gases and Pulmonary Circulation

T HE ANALYSIS OF BLOOD-GAS RELATIONSHIPS in the lungs is handicapped

Pulmonary Circulation Linda Costanzo Ph.D.

The physiological functions of respiration and circulation. Mechanics. exercise 7. Respiratory Volumes. Objectives

Chapter 4: Ventilation Test Bank MULTIPLE CHOICE

CHAPTER 3: The respiratory system

TERMINOLOGY AND SYMBOLS USED LN RESPIRATORY PHYSIOLOGY. Assistant, Medical Unit, Middlesex Hospital, London, W.i

CHAPTER 3: The cardio-respiratory system

PERFORMANCE AS RELATED TO COMPOSITION OF ALVEOLAR AIR1

Introduction. Respiration. Chapter 10. Objectives. Objectives. The Respiratory System

PCO2 levels apparently differed by less than 5 mm Hg. Fowler [1954] and. Godfrey and Campbell [1969] have shown that it is possible to resume a

By: Aseel Jamil Al-twaijer. Lec : physical principles of gas exchange

Respiratory System. Part 2

transfer, in part to difference of opinion regarding the mechanics of

exchange of carbon dioxide and of oxygen between the blood and the air in

Respiratory System. Prepared by: Dorota Marczuk-Krynicka, MD, PhD

Let s talk about Capnography

VENTILATION AND PERFUSION IN HEALTH AND DISEASE. Dr.HARIPRASAD VS

Circulatory And Respiration

AN OVERVIEW OF RESPIRATION AND AN INTRODUCTION TO DIFFUSION AND SOLUBILITY OF GASES 1

Respiratory Physiology. Adeyomoye O.I

partial pressure is to be applied to the dissociation curve of fully oxygenated

Measurement of cardiac output by Alveolar gas exchange - CO 2 -O 2 based methods

BREATH-BY-BREATH METHOD

Physical Chemistry of Gases: Gas Exchange Linda Costanzo, Ph.D.

Respiratory Medicine. A-A Gradient & Alveolar Gas Equation Laboratory Diagnostics. Alveolar Gas Equation. See online here

SIMULATION OF THE HUMAN LUNG. Noah D. Syroid, Volker E. Boehm, and Dwayne R. Westenskow

The Physiologic Basis of DLCO testing. Brian Graham Division of Respirology, Critical Care and Sleep Medicine University of Saskatchewan

Section Three Gas transport

Masaji Mochizuki ABSTRACT. ]p(deox). The Haldane effects of [CO2] and [HCO3. ] were obtained by subtracting [CO2]p(ox) from [CO2]p(deox) and [HCO3

2. State the volume of air remaining in the lungs after a normal breathing.

Capnography in the Veterinary Technician Toolbox. Katie Pinner BS, LVT Bush Advanced Veterinary Imaging Richmond, VA

Respiration - Human 1

THE literature on this subject, which was reviewed recently (CAMPBELL, doses of amytal, and in addition received A.C.E. mixture during the

Chapter 13 The Respiratory System

RESPIRATORY MUSCLES IN HEALTH AND EMPHYSEMA *

Measurement of cardiac output by Alveolar gas exchange - Inert gas rebreathing

Respiratory System Physiology. Dr. Vedat Evren

Vienna, Austria May 2005 MONITORING GAS EXCHANGE: FROM THEORY TO CLINICAL APPLICATION

Table of Contents. By Adam Hollingworth

1) Kety and others have attempted to predict

Chapter 17 The Respiratory System: Gas Exchange and Regulation of Breathing

LUNG CLEARANCE INDEX. COR-MAN IN Issue A, Rev INNOVISION ApS Skovvænget 2 DK-5620 Glamsbjerg Denmark


VOLUNTARY BREATHHOLDING. I. PULMONARY GAS

Respiratory Physiology Gaseous Exchange

02 (Do2) and three using CO (Dco) namely, the

Paul V. Jennemann Maryland Radon Laboratory, Inc Corporate Court, Suite E Ellicott City, MD 21042

A NEW METHOD FOR ASSURING ALVEOLAR-EQUILIBRATED BREATH ALCOHOL SAMPLES. A. Slemeyer, Ph.D.* SYNOPSIS

660 mm Hg (normal, 100 mm Hg, room air) Paco, (arterial Pc02) 36 mm Hg (normal, 40 mm Hg) % saturation 50% (normal, 95%-100%)

SUBCUTANEOUS GAS EQUILIBRATION IN

Predictors for oxygen and carbon dioxide IeveIs during anzesthesia*

CHAPTER 6. Oxygen Transport. Copyright 2008 Thomson Delmar Learning

BREATHING CIRCUIT. II. PULMONARY FIBROSIS

SERIAL DETERMINATION OF CARDIAC OUTPUT DURING PROLONGED WORK BY A CO2-REBREATHING TECHNIQUE

TV = Tidal volume (500ml) IRV = Inspiratory reserve volume (3,000 ml)

NORMAL CARDIAC OXYGEN CONSUMPTION

The physiological basis of pulmonary gas exchange: implications for clinical interpretation of arterial blood gases

MEDICAL EQUIPMENT IV MECHANICAL VENTILATORS. Prof. Yasser Mostafa Kadah

PROBLEM SET 9. SOLUTIONS April 23, 2004

throughout. The constant-flow respiration was administered through a intravenously at appropriate intervals (in addition to the general

BREATHING AND EXCHANGE OF GASES

Respiratory system & exercise. Dr. Rehab F Gwada

RESPIRATORY PHYSIOLOGY. Anaesthesiology Block 18 (GNK 586) Prof Pierre Fourie

Oxygen convulsions are believed by many workers to be caused by an accumulation

LAB 7 HUMAN RESPIRATORY LAB. Complete the charts on pgs. 67 and 68 and read directions for using BIOPAC

The over-ventilated cat shows a similar adjustment to diminished. being over-ventilated, and he considered that on that account there was

LOW PRESSURE EFFUSION OF GASES revised by Igor Bolotin 03/05/12

technique which have led to increased precision

Hypoxia Following Rapid Decompression to 18,288 m (60,000 ft) Attributable to Alveolar Hypoventilation

Yanal. Jumana Jihad. Jamil Nazzal. 0 P a g e

Tter person TERM PAPER. Date: 30/4/ MEDICAL VENTILATOR

Chapter 13 The Respiratory System

that, as a means of progression, walking is suitable for lower speeds

medical physiology :: Pulmonary Physiology in a Nutshell by:

PROBLEM SET 7. Assigned: April 1, 2004 Due: April 9, 2004

CARBON DIOXIDE ELIMINATION FROM SEMICLOSED SYSTEMS

P215 Respiratory System, Part 2

Gas exchange and ventilation perfusion relationships in the lung

4. For external respiration to occur effectively, you need three parameters. They are:

By S. GODFREY and E. J. M. CAMPBELL. From the Department of

Recitation question # 05

CHAPTER 16 %UHDWKLQJ*DV0L[LQJ3URFHGXUHV

PURE SUBSTANCE. Nitrogen and gaseous air are pure substances.

4/18/12 MECHANISM OF RESPIRATION. Every Breath You Take. Fun Facts

IV. FROM AQUATIC TO ATMOSPHERIC BREATHING: THE TRACHEA & THE LUNG

For more information about how to cite these materials visit

HUMAN Sample Experiment High Altitude Simulation (a one variable experiment) (version 5/04/06)

Transcription:

A CONCEPT OF MEAN ALVEOLAR AIR AND THE VENTI- LATION -BLOODFLOW RELATIONSHIPS DURING PULMONARY GAS EXCHANGE HERMANN RAHN From the Department of Physiology and Vital Economics, University @ Rochester, School of Medicine and Dentistry ROCHESTER, NEW YORK I N THE past many different methods have been employed for the direct sampling of alveolar air. A sound criticism of the validity of the technique has usually been futile since one was at loss to define or determine mean alveolar composition. The ease with which alveolar air composition can be altered by the slightest change in ventilation is very impressive and makes one aware of the possibility of unequal ventilation in various parts of the lung and the consequential regional variability of gas concentration. The concept of unequal bloodflow to the various alveoli has received less attention, although this factor is equally important in altering the gas composition. It is the purpose of this paper 1) to define the alveolar air composition in terms of alveolar ventilation and pulmonary bloodflow which allow one to define a concept of mean alveolar gas composition; 2) to discuss a method for the direct sampling of mean alveolar air; 3) to compare this with the Haldane technique of sampling alveolar air; 4) to predict on the basis of the ventilation-bloodflow equations the effect of unequal ventilation and bloodflow upon the alveolar-arterial oxygen gradient. A Concept of Mean Aheolar Air. The alveolar air equation and the alveolar ventilation equation have given us a theoretically precise definition of the relation of the alveolar-gas concentrations and the ventilation (I). When this equation is combined with the Fick equation, it allows one to express the alveolar gas concentration in terms of bloodflow and ventilation (a). Let F = bloodflow in liters/min. Va = alveolar ventilation in liters/mm. B.T.P.S. (A-V)02 = arterial-venous oxygen difference in ml/l. x0 = oxygen intake in ml/min. S.T.P. Q = respiratory quotient PC = partial pressure of CO2 in alveolar air. then the bloodflow according to the equation of Fick is Xo = F(A-V)G 0 I and the alveolar ventilation according to Fenn et al. (I) is Va X pc x0 = ~.864Q 02 Combining the equations and eliminating X0 we have pc = ;a(a-v)od.86~q) (3) Received for publication March 14, 1949. 1 Work done under contract with the Air Materiel Command, Wright Field. 21

22 HERMANN RAHN Volume 158 The ~02 can be calculated for equatiort 3 from the alveolar air equation if the R.Q. is known. Since Va and F appear as a ratio, the equation becomes independent of metabolic rate. The pcoe, ~02 and R.Q., therefore, become a function of the Va/F for any given inspired gas tension and mixed venous blood gas tension (see below). The solution of this equation for a given steady state is most easily accomplished by a graphic method. If one assumes a specific pr/2 and pco2 tension of the mixed venous blood entering the lung as well as an inspired oxygen cension, then one can graphically, with the aid of the Henderson nomogram for blood and the Penn diagram (I) for gas R.Q., determine all the simultaneous p0~ and pcoz tensions which satisfy equation 3. This is done in the following manner. Various gas R.Q. lines are plotted radiating from the inspired 02 tension, I, on the Fenn 02 - CO2 diagram (fig. I). The point describing the 02 and CO O2 CONTENT VOL % I5 It 18 18.5 19. 19.4 19.6 19.8 -~- - ~~ - 40 50 60 70 80 90 100 110 120 I30 MO I. Fig. I. THE CURVE (SOLID LINE) represents all the possible simultaneous 02 and CO2 tensions which could theoretically exist in the pulmonary capillaries and the alveolar air when the mixed venous blood has the composition V, and the inspired gas tension has the composition I. The solid diagonals represent various iso-gas R.Q. lines and the dotted lines the iso-oxygen content. Each point on this curve is the product of a certain ventilation-bloodflow ratio, Va/F, which simultaneously determines the respiratory quotient, Q, at which the blood and alveoli are exchanging. tensions of the mixed venous blood, V, is likewise located on the diagram. A straightedge connecting the venous 02 and CO% tensions of V on the blood nomogram is then pivoted on its point of intersection with a chosen blood R.Q. point until the pcoz and ~02 values correspond to identical values on the diagonal of figure I representing the same R.Q. At these tensions only, can blood and alveolar gases exchange at the same R.Q. Similar points can be found for various other R.Q. s which yield a curve (fig. I) denoting all the possible combinations of CO2 and 02 tensions which could exist under these conditions. Since the original development of this procedure (2) Riley (3) has (personal communication) proposed quite independently a similar solution. Essentially, he plots all the possible 02 and CO:! tensions for a given blood R.Q. coming from a given venous point and shows where they intersect the gas R.Q. line. This procedure has much merit for it affords a more graphic visualization of blood and gas exchange on the OhCO2 diagram. It follows from the equation that any point along this curve is the result of a particular alveolar ventilation to bloodflow ratio, Va/F. To determine this ratio from eqtiation 3 the (A-V) oxygen difference must be known in addition to the pco2 and Q. This can be obtained from the isopleths of arterial 02 content that have been added to the figure I. Thus, between the venous point, V, where the ventilation is o, and the other end of the curve I, where the bloodflow is o, an infinite number of Va/F ratios can theoretically exist in the various alveoli. In the alveoli where normally the maximal exchange occurs, at an R.Q. of.8, the Va/F ratio in this particular example is 1.0. PO2

J&Y I949 ALVEOLAR AIR STUDIES 23 We have now defined for this specific example all the possible simultaneous 02 and CO2 tensions which could exist in any part of the lung as well as in the pulmonary capillary blood if we assume that the terminal diffusion gradient across the alveolar membrane is for practical purposes negligible. The next object is to determine the mean alveohr gas concentration. This is done easily, if the R.Q. is known. Thus, if we choose in our example an R.Q. of.8 then the intersection of this gas R.Q. line with the curve of figure I determines the only point at which blood can exchange at this particular R.Q. This is at a pco2 and ~02 of 40 and IOO mm. Hg respectively and assumes that all blood in all the alveoli is exchanging at this particular R.Q. Of course, it is very probable that this is not normally the case and that alveoli exchange individually at various R.Q. s and that only the mean of all of them result in an R.Q. of.8. As will be discussed below, a normally distributed population of Va/F values will not appreciably affect the predicted alveolar value, but only change the arterial poz. The validity of the theoretical alveolar air curve (fig. I) should be experimentally demonstrable if one could alter the Va/F ratio without changing the steady state and the venous tension, V. The closest approach to such a test can be accomplished by analysis of the alveolar air composition after breath holding and hyperventilation when this is done at various intervals up to one circulation time (20 sec.). It might be assumed that the venous tension will remain constant during this period. Such experiments have been previously described (4), and are here compared with the theoretical curve (fig. 2). Although a discrepancy is apparent, probably due to altered CO2 output, cardiac output and partial recirculation, a general agreement is rather striking and lends support to the theoretical conclusions regarding the possible combinations of CO2 and 02 which could exist simultaneously in the alveoli. It has always been an impressive fact that the simultaneous gas tensions could be altered only along the steady state was altered a very narrow and predictable pathway no matter by what method (5). Sampling of Mean Alveolar Air. It has been shown above that the mean alveolar air can be theoretically defined provided 3 facts are known: I) the venous gas tensions, z) the inspired gas tensions and 3) the R.Q. (It also presupposes that there exists no terminal alveolar membrane gradient.) The question now arises how close these values for the theoretical mean alveolar air can be approached by direct methods which do not involve the sampling of mixed venous blood. Riley et al. (6) have approached this problem by collecting and analyzing the arterial blood for the CO2 tension. Since such a sample represents a mixture of practically all the blood that has passed through the pulmonary capillaries, it must represent the mean arterial pco2 tension and is for all practical purposes in equilibrium with the alveolar pcoz. (It can be shown that a considerable venous admixture has a negligible effect upon the mean arterial pco2 tension. Furthermore, it is shown below that a normal probability distribution of Va/F among the alveoli, likewise has a negligible effect.) On the basis of the theoretical discussion above, this mean arterial pco2 value should be identical with the mean alveolar CO2 tension. (This theoretical mean tension has been designated as ideal tension by Riley (3)). Thus, substituting mean alveolar CO:! for mean arterial pco2 and determining the respiratory quotient from the expired air, Riley is able to calculate the mean alveolar flz from the alveolar air equation. This method is theoretically entirely sound for obtaining the mean alveolar composition but offers practical difficulties since it requires an arterial puncture and considerable skill in the determination of arterial pcoz. Furthermore, any single determination of arterial pcoz by the method of Riley et al. (6) can only be read with an accuracy of rf= 3 mm. pc0~.

24 HERMANN RAHN Volume 158 On the other hand, methods of obtaining alveolar air directly offer many practical advantages and it is our purpose to ascertain how closely these methods approach the theoretical concept of mean alveolar air. In the past there have been essentially 2 methods of sampling alveolar air. In the original method (Haldane) all the expiratory reserve was forced out of the lung and the last part analyzed, while others have sampled from the last part of each normal tidal volume. These 2 methods do not yield identical results and the difference can probably be best appreciated when the time course of CO2 concentration is recorded for each individual breath on a fast infrared CO2 analyzer recently described by Fowler (7) from this laboratory (fig. 3). It can be seen that after the deadspace is washed out with a normal tidal expiration, the CO2 concentration rises quickly and tends to plateau off. With a forced expiration (Haldane), however, the alveolar CO2 keeps on rising. This curve is typical of some 15 healthy individuals who have been recorded by this method. IO * 76 80 90 100 110 120 130 140 AN. p 02 Fig. 2. THEORETICAL ALVEO- LAR AIR COMPOSITION CURVE (solid line) compared with directly obtained samples (dashed line) when - the Va/F ratio of the normal alveolar air (open circle) is altered by breath holding or hyperventilation. - (see text). With the Haldane technique part X is sampled. In a method described by us recently (5, S), part Y is sampled. In this example the CO2 difference between these 2 points is approximately 3 mm. Hg. Sampling the last part of each normal tidal has several advantages, for it averages the last IO-IS cc. of each tidal volume expired during normal breathing and, furthermore, it does not require trained subjects for delivering a properly timed, forced expiration. In addition to the automatic sampling the continuous analysis is extremely convenient. In order to determine the reliability of these samples as representing mean alveolar air, tests were performed comparing the alveolar pcoz with the arterial pcoz. The CO2 comparisons were carried out by Miss Suskind in this laboratory (unpublished). While the alveolar air was analyzed continuously by the method referred to above, blood samples were taken from the radial artery in the human subjects and the femoral artery in the dogs. This approach allowed for simultaneous sampling of these 2 components. Nine experiments were carried out on man and 80 were done on dogs under nembutal or pentothal narcosis. The mean difference

I B I I I I t I I1 t 1 I I I 11 I J@JY I949 ALVEOLAR AIR STUDIES 25 for all experiments between the alveolar pcoz and the arterial pco2 was 0.78 mm. Hg, standard error of the mean 0.58. (In our hands we find that on the average the pco2 determination of the blood differs from the equilibrating test gas mixture by less than.3 mm. Hg with a standard deviation of 2.5.) These observations would suggest that the alveolar pco2 obtained by this method of sampling from the last fraction of each tidal volume is in very close agreement with the arterial pco2. Therefore, this value, as pointed out above, represents the mean alveolar pcoe unless an appreciable terminal membrane gradient exists, which is unlikely (6). In the continuous method of alveolar air analysis the ~02 is simultaneously therefore, represent the mean alveolar ~02 provided that the identical to the expired air R.Q., the latter representing the analyzed and must, alveolar air R.Q. is classical standard. To test the possible discrepancy between these, the alveolar R.Q. was determined by continuous alveolar air analysis and compared with R.Q. values from the Fig. 3. INSTANTANEOUS co2 CONCENTRATION recorded by an infrared analyzer during a normal expiration and a forced expiration. The simultaneous expiratory velocities are recorded below. The inspiratory velocity curve is not shown. X and Y denote the part of the alveolar air sampled by the Haldane technique and the continuous technique, respectively. i NORMAL EXRR. I ; N.INSP i FORCED EXPIR. i INS!? collected expired air. The expired air was analyzed by the same automatic meters as well as by Haldane gas analyses in 27 experiments on 7 different subjects. The average values are presented in table I A and show no significant difference between the expired air and the simultaneous alveolar air R.Q. These results would suggest that this method of sampling yields an R.Q. which is in agreement with expired air R.Q. values. Thus, we may draw the conclusion that the alveolar air sampled continuously from the end of normal tidal expirations, yields a value which must be very close to the theoretical mean alveolar ~02 and pcoz. The other method (Haldane) for sampling alveolar air must also be discussed. This method analyzes the last part of the forced expiration. When this method is compared with samples taken by the previous method (8) one finds on the average a 2 mm. higher CO2 and a 5 mm. lower ~0% for the Haldane technique. This is not surprising when we look at figure 2 and also consider that this forced expiration usually lasts 2-3 seconds beyond the time taken for a normal expiration (end-expiratory sample). Similar differences were obtained by Riley et al. (6) who compared the alveolar CO2 obtained by the Haldane technique (end-inspiratory samples) with the arterial pco2. They observed on the average a 4.4 mm. Hg higher value in the alveolar sample taken at rest. SECONDS

26 HERMANN RAHN Volume 158 It should be pointed out that the subjective impression of the time it takes to expire completely may be quite misleading, unless a simultaneous air velocity record is obtained. It is during the last phase of expiration that the CO2 in many subjects rises rather steeply due to the smaller lung volume which is still exchanging with the blood. Actually, tests have shown (unpublished) that during this prolonged expiration, the oxygen uptake remains normal, but the COz output is reduced. The net result is that not only must the CO2 rise above and the O2 fall below the average value existing at the end of a normal tidal, but the ratio between oxygen uptake and CO2 output is altered, producing an abnormally low R.Q. These changes become exaggerated when larger intervals than 2-3 seconds are used for the forced expiration or when the breath is held (4). Table I B shows the alveolar R.Q. differences obtained by the 2 methods of sampling. These experiments were done on IO subjects and were reported elsewhere (8). But in view of the values cited in table I A, they assume new interest A COMPARISONOF EXPIRED AIRB.Q.ANDALVEOLAR AIR R.Q. (END OF NORMALTIDAL SAMPLE) TABLE $y S.E.M. ta.. -- Expired air R.Q............828.OIO 27 Alveolar air R.Q............82g 307 27 A...................... I ALVEOLARR.Q.OBTAINED B BY SAMPLESFROM: End of normal tidal expiration.................82 I.0052 148 End of forced expiration.....7go 30541 148 A...................... I l O3I I I since they show the Haldane method to deviate from the expired air R.Q. and by an average value of.03 R.Q. units. This would support the contention that a forced expiration is actually equivalent to breath holding which brings about similar changes in 02, CO2 and R.Q. of alveolar air (4). The 02 and CO2 Dead Space. The discrepancy between the tidal air samples and forced expiration samples, furthermore, explains the difference which has been noted by others between the dead space calculated from the oxygen values and CO2 values. Theoretically, it can be shown that this dead space must be the same as long as the R.Q. of the expired and alveolar air are the same. The reason for the observed difference of a larger oxygen dead space is very probably that the alveolar samples were always obtained by the Haldane technique. Figure 4 shows the average expired air, E, and the alveolar air, A, values obtained in 27 experiments in which the alveolar COZ, O2 and R.Q. values were 38.1, 102 and.829 and the expired COZ, deadspace O2 and R.Q. were 27.8, 114 and A328 respectively. The Bohr formula, tidal volume = A-E can be represented graphically in figure 4 for the 02 as well as the CO2 A A-E values. The ratio ---A- must be equal for both sides of the quadrangle as long as both A and E are on the same diagnonal or R.Q. line.

Julr I949 ALVEOLAR AIR STUDIES 27 If one assumes on the basis of the former experiments (6) that a Haldane sample had been delivered instead, the alveolar air values would have been located at point A-I in figure 4. During the delivery of the sample, the concentration of point A would change and move up on the breath holding curve, B.H. (4). The actual values cited above yield with the average tidal volume of 648 CC. (B.T.P.S.) an O2 and CO2 deadspace of 176 cc. If we subtract a 35 cc. apparatus deadspace from this figure, we obtain a personal deadspace (breathing through the nose) of 140 cc. Had Haldane samples been used instead, the personal deadspace Fig. 4. A AND E REPRESENT the average alveolar and expired gas concentrations which fall upon the same R.Q. diagonal. The relative dead space to tidal volume ratio is shown graphicaly for 02 and CO2 and are the same as long as the R.Q. for E and A are the same. Point A-I represelnts the alveolar value which would have resulted if the sample had been delivered from a forced expiration instead of from the end of a normal tidal expiration. The broken curve, B.H., describes the alveolar air changes when the breath is held at A (see text). would have been 164 cc. for CO2 and 188 cc. for 02. On the basis of the foregoing discussion it would appear that the deadspace values derived from Haldane samples are probably too large, particularly for the 02 deadspace. Effect of Unequal Ventilation and BloodJlow upon the Alveolar-Arterial Gradient. In the foregoing discussion the concept of the theoretical mean alveolar gas concentration was based upon the assumption that all alveoli exchanged at the same R.Q. However, there is much evidence that ventilation is not equal in various parts of the lung (for a recent review see Rauwerda (9)) and Wearn et al. (IO) have shown that the bloodflow is not constant in the alveoli. Thus, to appraise the variations in gas concentrations that may exist from one alveolus to the next and what effect this would produce upon the mean alveolar gas composition as well as upon the mean arterial gas tension, the variation of bloodflow and alveolar ventilation must be considered. Since both exert their effect upon the gas tensions, it is convenient to con-

28 HERMANN RAHN Volzcme 158 sider them simultaneously and to evaluate the effect of the variation of alveolar ventilation to bloodflow ratio, Va/F (I I). From equation 3 we obtain by rearrangement : Va -F=.864 Q (A-V)02 If we return to our original conditions of our example, figure I, with a R.Q. equal to.8 then the mean alveolar ~02 and pco2 must be 100 and 40 mm. Hg respectively, provided all the blood in ali the alveoli is exchanging at this R.Q. Furthermore, these particular tensions are brought about by a Va/F ratio of 1.0. Theoretically other Va/F ratios can occur ranging from o at the venous point to a at the inspired gas tension. Therefore, we may assume that the distribution of PC TABLE 2 A) Values which will be found at the various standards of deviation which are not apparent in jig.4-3 -2-1 MEAN 3-I +2 +3 -- Va/F......... 945 49-77 1.00 1.30 I.69 2.20 R.Q.......... -53-60 -68,230 1-98 I.17 1.38 B) Blood and alveolar values which wodd be obtained if all alveoli exchanged at a Va/F ratio of LO, (A), are compared with the mixture which wodd result if the Va/F ratio varied arozcnd the mean (B) (see text) 02CONTENT C02CONTENT ALV.P02 ALV.PC02 A... 19-Q 48.00 100 40 B... 19-55 47-90 99-4 39-7 Difference... 0.10 0.10 0.6 o-3 the pulmonary bloodflow, F, as well as the ventilation, Va, among the various alveoli is normal along a logarithmic scale.2 The distribution of the ratio Va/F will then also be normal along a logarithmic scale. Returning to our example, we can say that not all alveoli have a Va/F of 1.0 but that some have a larger and others a smaller ratio distributed along a normal logarithmic distribution curve with the mean of the log 1.0. A standard deviation equal to the log 1.3 is arbitrarily chosen. Table 2 A lists the various Va/F ratios and R.Q. s which then will be found at I, 2, and 3 standard deviations from the mean Va/F of 1.0 and figure 5 shows how this distribution affects the O2 and CO2 content of the arterial blood and the ~02 and pco2 of the alveolar air. The resulting mixtures which would result for each of the 4 entities are calculated (the sum of the values of each class interval multiplied by the frequency of its occurrence) and listed in table 2 B to be compared with the theoretical mean value which would be obtained if no variation of Va/F had oc- ft Among the various kinds of distribution curves, this is probably the simplest form which could be assumed for the distribution of a ratio.

July I949 ALVEOLAR AIR STUDIES 29 curred as originally assumed. It can be seen that from a practical standpoint none of the resulting mixtures differ from the theoretical mean with the exception of the 02 content. Here we find that the arterialized blood leaving the lung capillaries has an 02 content 0.1 volume per cent lower than if all the exchange had gone on at a Va/F of 1.0. The arterial blood leaving the capillaries is, therefore, represented by the open circle (fig. 5> and it can be seen that this is at an oxygen tension 8 mm. Hg lower than the mean alveolar 02 tension. (Although the CO2 content of the mixture also differs from the theoretical value by the same amount as the 02 content, it affects the arterial pcoz by less than 0.2 mm. Hg.) It should be pointed out that the Or CONTENT - VOL. %. 70 80 90 IO0 II0 120 130 PO2 z 49 z 47 $ Fig. 5. DISTRIBUTION OF THE PULMONARY blood gas values and alveolar gas values when a normal logarithmic distribution of Va/F is assumed around the mean value (solid circle). The resulting average mixture of the arterial blood will be altered only in respect to the oxygen content and arterial ~02 (open circle). The resulting average mixture of alveolar gases remains essentially unchanged. Thus, the distribution of Va/F induces an alveolar-arterial p0~ gradient of 8 mm. Hg (see text). mixed alveolar air as well as the mixed arterial blood points (table 2, B) no longer lie precisely on the blood R.Q. or gas R.Q. line of 23. This would suggest that the Va/F ratios are not symmetrically, but unequally distributed in such a manner that the mixed values still maintain an R.Q. of 2. However, the above example is a first approximation and the discrepancy in this case may be considered negligible. When, under otherwise identical conditions, various other venous points are chosen, the ~02 gradient is not appreciably altered. This means that a large or a small (A-V)02 difference does not affect this gradient. On the other hand, if a larger deviation of Va/F than log. 1.3 is assumed, the ~02 gradient can become appreciably larger. This may explain the greater alveolar-arterial oxygen gradient observed during exercise by Riley et al. (6). It should also be pointed out that an unequal distribution of Va/F ratios will result in increased 02 gradients, particularly if a preponderance of alveoli have a Va/F ratio which is smaller than the theoretical mean. 45 ; 43 d 41 $

30 HERMANN RAHN Vohr21ae I58 As discussed before, the standard deviation of this ratio was quite aribtarily chosen and at present there is no way to ascertain the magnitude of this deviation nor whether the distribution of this Va/F ratio is distributed symetrically or asymetrically. On the other hand, with the above assumption we can say that in the normal lung this deviation is no greater than the one we assumed because the gradient of 8 mm. poa obtained is of the same order of magnitude as that observed for the total gradient normally occurring (6). This gradient has so far been largely attributed to venous admixture arising from direct venous shunts, Thebesian and bronchial veins. SUMMARY An equation is derived which expresses the alveolar gas concentration in terms of the relative alveolar ventilation and pulmonary bloodflow. A graphical solution of this relationship is given which describes all the simultaneous O2 and CO2 concentrations which could theoretically exist for given mixed venous and inspired air tensions of these gases. Each of the possible alveolar air values, and therefore each R.Q., is determined by a definite ventilation to bloodflow ratio. If the R.Q. is known, the theoretical mean alveolar air composition can be defined by this equation. This theoretical concept of mean alveolar air presupposes that the ventilation to bloodflow ratio is the same in all the alveoli. Since this is unlikely, a variation of this ratio along a normal distribution curve is assumed. The mean alveolar air mixture resulting from such a distribution does not differ appreciably from the theoretical mean. The resulting arterial blood mixture, however, yields a lower poa tension, thus giving rise to an alveolar-arterial oxygen gradient. Evidence is presented which indicates that the sampling of alveolar air from the last part of each normal expiration yields a value which is very close to the theoretical mean alveolar air composition, while the Haldane method of sampling yields CO2 values which are slightly too high and R.Q. values which are slightly too low. The latter method is responsible for the difference in dead space volumes when they are calculated separately from the 02 and CO2 values. Theoretically, the volumes should be the same if the expired air R.Q. and alveolar air R.Q. are equal. The author wishes to acknowledge the valuable criticism and suggestions received from his colleagues, Drs. A. B. Otis and W. 0. Fenn, during the preparation of this manuscript. REFERENCES I. FENN, W. O., H. RAHN AND A. B. OTIS. Am. J, Physial. 146: 63 7, 1946. 2. RAHN, H. Am. J. Physiol. 155: 462, 1948. 3. RILEY, R. L. Personal communication. 4. OTIS, A. B., H. RAHN AND W. 0. FENN, Am. J. Physiol. 152: 675, 1948. 5. RAHN,H. AND A.B. OTIS. J. Applied Physiol. I: 717, 1949. 6. RILEY, R. L., J. L. LILIENTIIAL, JR., D. D. PROEMMEL AND R. E. FRANKE. Am. J. Physiol. 147: 191, 199, 1946. 7. FOWLER, R. C. Rev. Scients. Instruments. 20: 175,rgJg. 8. RKHN, H, J. MOHNEY, A. B. OTIS AND W. 0. FENN. J. Aviation Med. I 7: I 73, 1946. 9. RAUWERDA, P.E. Unequal Ventilation of Dijj erent Parts of the Lung. Dissert : Groningen, 1946. IO. WEARN, J.T. et al. Am. J. Physiol. Iog: 236, 1934. I I. RAHN, H. Federation Proc. 8: 129, 1949.