CLEAN-PROTECT Emergency Gas Release Absorber Models: CP500SF, CS1000SF

Similar documents
Customer Responsibilities

Oxford Instruments Plasma Technology. PlasmaPro NGP80. Installation Data Sheet. Original Instructions.

Information Sheet. About this information sheet. Floor and wall loadings. Attachment of process module to floor. PlasmaPro Estrelas100

AIRLINE-SERIES HELMET AIR FILTER

LK-SX VOC. Application. Security Advice Caution. Notes on Disposal. Combined sensor mixed gas. Data sheet

490 Micro GC Site Preparation Checklist

Model MTB-ASME Vertical Bladder Tanks

Model MTB-ASME Vertical Bladder Tanks

Pneumatic dead-weight tester Model CPB3500

High Pressure Breathing Air Compressors

Vertical Bladder Tanks

Cellular Gas Filters DF 100. Product Information

Infrared Linescanners

Self-operated Pressure Regulators Type 2405 Pressure Reducing Valve

Use of Hazardous Gases Standard Operating Procedure

MMS Mercury Monitoring System for Natural Gas

Model MTB-ASME Horizontal Bladder Tanks

Horizontal Bladder Tanks

T 2523 EN Type 2406 Excess Pressure Valve Self-operated Pressure Regulators ANSI version

Digital pressure gauge Model CPG500

HORIZONTAL BLADDER TANK

VERTICAL BLADDER TANK

Air Operated Hydraulic Pumping Systems to 50,000 psi

LK-SX CO 2 +VOC. Application. Security Advice Caution. Notes on Disposal

High-performance submersible pressure transmitter For level measurement Model LH-10

Mass Flow Meter (MFM) for Gases

Operating Instructions. Ball valve fitting according to ZB For pressure transmitter VEGABAR 82. Document ID: 50027

Precision pressure sensor Basic version Model CPT6020

NGN Series nitrogen generator

Compact pressure switches for gas and air

Gas-Detection Instruments

Pressure transmitter PASCAL Ci4

Ball Float Steam Trap UNA 45 MAX, UNA 46 MAX, UNA 46A MAX PN 40/Class 300 DN 40, 50, 65

MEDAP-MOBILE GAS SUPPLY

High-performance submersible pressure transmitter For level measurement Model LH-10

PROCESS GAS SAMPLING SYSTEMS

Self-operated Pressure Regulators for special applications

BY GREGGERSEN CATA LOG

Types ACE95 and ACE95Sr Tank Blanketing Valves

MEDICAL EQUIPMENT CATALOG

Air Differentail Pressure Switch

PROCESS ANALYSERS. SERVOPRO PureGas. Gas Purifier. Operator Manual. Part Number: A Revision: 0 Language: UK English

Gas Cabinets and Valve Manifold Boxes: Applying CGA G13- Rev 2015 to Gas Delivery Equipment

Type 4708 Supply Pressure Regulator

BULLETIN E485A. Standard Interface Poppet Valve Construction Customized Solutions Plug-and-Play Design.

SITRANS P measuring instruments for pressure

FOAM TANK (1/2) DATA SHEET

Energy Management solutions for compressed air and industrial gases. vpinstruments.com

Peak Pressure Indicator MSI-3

Differential pressure

BULLETIN E485B. Poppet Valve Construction Customized Solutions Plug-and-Play Design. Subject to technical modifications.

Hydraulic comparison test pump Models CPP1000-X, CPP1600-X

FOAM TANK (1/2) DATA SHEET

FLAMMABLE GASES AND FLAMMABLE CRYOGENIC FLUIDS

MOBILAIR M 235. Portable Compressor With the world-renowned SIGMA PROFILE Flow rate 18.1 to 23.3 m³/min ( cfm)

Model PDT Dewpoint Transmitter

FPG8601 Force Balanced Piston Gauge

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI

Do you require maximum pressure stability in your gas supply?

Description Advanced Features Typical Applications

Armatures for analytical probes

NGP-250/500 Nitrogen Generator Quick Start Guide

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

The routine maintenance and inspection of local exhaust ventilation (LEV)

TYPICAL TOXIC GAS SYSTEM INSPECTION VIOLATIONS

...makes sense! Combined CO 2 /O 2 analyzers. Monitor your process in real-time: OUR CER. BlueSens.com

High-performance submersible pressure transmitter For level measurement Model LH-20

Draw-wire system SZG165

Vibration isolation system 1VIS10W. User manual

Security and confidence at height.

GAS PRESSURE CONTROL UNIT TYPE 132

A17W23_MASE_MUS_EN MANUAL

JUMO dtrans p30 Pressure Transmitter

Full-Vacuum Chlorinator C 2212 MB / 1

PRESSURE TANKS HANDLING & INSTALLATION INSTRUCTIONS INSTALLATION MANUAL CONTROL VALVES

Noth American 7347 High Pressure Gas Regulators

TRZ 03-K Volumeter. Proven Technology. Superior Performance. TRZ 03-K Volumeter is a Turbine Gas Flowmeter for Secondary Gas Metering.

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI US Edition

490 Micro GC Site Preparation Checklist

Vertical and Horizontal Bladder Tanks

S265 Remote seals with capillary tube. 2600T Series Pressure Transmitters. Engineered solutions for all applications

NEW: CO2 incubator with sterilizable sensor

Introduction. Description. Series P48 Pressure Controls for Steam, Air or (hot) Water. Feature and Benefits

Types ACE95 and ACE95Sr Tank Blanketing Valves

Series 44 Self-operated Pressure Regulators. Type 44-0 B Pressure Reducing Valve. ANSI version

pressure regulator Zero pressure regulator Proportional pressure regulator Compressed air-controlled

Valve Proving System VDK 200 A S06*

Series MG Mixing Tubes

ATM/GR. Electronic pressure switches CUSTOMER BENEFITS

Mounting and operating instructions EB 2530 EN. Self-operated Pressure Regulator. Pressure Reducing Valve Type M 44-2

Gas Appliance Pressure Regulators with integrated gas filter. FRI/6 Series

Pressure booster combination DPA-CRVZS. Operating instructions a [ ]

Installation, commissioning and servicing instructions

Type ACE95jr Tank Blanketing Valve

Instructions for Use. Plug connection for medical gas and vacuum acc. to DIN / 2004 DIN EN ISO

Technical Information Conducal CLY421

Technical Data Sheet T 2025

TECHNICAL DESCRIPTION

Ball Float Steam Trap UNA 43 PN 16/CL 125/JIS 10K UNA 46 PN 40/CL 150/CL 300/JIS 10K/JIS 20K DN 80, 100, 150, 3", 4", 6"

Transcription:

CLEAN-PROTECT Emergency Gas Release Absorber Models: CP500SF, CS1000SF Controlled product information. Intended use: technical reference for quotations and similar customer projects. Not intended for general distribution or for advertising purposes. 2015 - AG Property of AG All rights reserved. Rev. 201530518

Product Description CLEAN-PROTECT Series CLEAN-PROTECT CP500SF /CP1000SF S S S Customer Gas sensor Customer alarm and safety system CLEAN-PROTECT emergency absorber hooked up to three gas cabinets. Schematic depicting emergency release in one cabinet. Leaker cabinet Safeguard against accidental release of hazardous gases Hazardous process gases are commonly used in the chemical, pharmaceutical, and semiconductor industries, among others. Most usually, the gases are supplied to the process from cylinders which are housed in an air-extracted cabinet. Larger supply vessels are often stored in concrete bunkers connected to a forced ventilation duct. Hazardous release from gas cylinders poses a very serious threat to the workforce and factory neighborhood. The CLEAN-PROTECT product line was specially developed to absorb toxic, corrosive, or pyrophoric gases during an emergency gas release incident. At the heart of the CLEAN-PROTECT system is the dry chemisorbent material, CLEANSORB. Installed in-line, the system is constantly on stand-by. Escaping gases undergo an irreversible chemical reaction (oxidation or neutralization) within the CLEAN-PROTECT system, where they are safely converted into non-volatile, solid by-products. Provided the system has not absorbed gas, the chemisorbent bed has a stable lifetime of up to five years between change-outs. CLEAN-PROTECT Emergency Gas Release Absorber High air extract flowrates, protection of multiple gas cabinets Scrubbing capacity for full gas cylinder Low pressure drop Permanently online, practically no maintenance Fully passive no electrical connections Typical 5 years service life between absorber refills Applicable to a wide range of hazardous gases, including: AsH 3, BF 3, Br 2, Cl 2, ClF 3, COCl 2, F 2, HCl, HF, HBr, H 2 S, H 2 Se, HCN, NH 3, N 2 H 4, PH 3, SO 2 Worldwide Service and Support customers can avail of a worldwide sales and service network. Given the important safety function assigned to the CLEAN-PROTECT system, commissioning, maintenance and refilling is only permitted by authorized service partners. CP systems can also be used for selected non-emergency applications involving high airflows. 2

Product Description CLEAN-PROTECT Series Important! The configuration of a CLEAN-PROTECT emergency absorber system requires careful consideration by the manufacturer of the exhaust gases to be treated and the associated installation. Before requesting a system recommendation or quotation, please ask your authorized sales and service partner to provide you with a Process Definition form so that we can recommend a model and configuration which is optimized for your process. Available Models Column Size CLEAN-PROTECT CP500SF Approx. 500 liter CLEAN-PROTECT CP1000SF Approx. 1,000 liter Basic System Components and Configuration System Description Cylindrical absorber column, constructed from 316L stainless steel. Filled with CLEANSORB granulate to safely remove hazardous gases by irreversible chemical reaction at ambient temperature. The scrubber medium is free of combustible materials such as activated carbon or organic binders. To be installed in the air extract ducting downstream of one or several gas cabinets, allowing permanent airflow through the absorber bed. Specially designed to handle high airflows with minimal pressure drop. Housing containing dust filter at inlet of CP system, fitted with lid for quick changeout of filter bag. Documentation 2 individual differential pressure gauges mounted on cylindrical body to monitor pressure drop across inlet dust filter and main absorber bed. Anchoring sockets on support legs for seismic protection. Operating manual in English language with customer-specific specifications and system check-out protocol. 3

Product Description CLEAN-PROTECT Series Optional Accessories Dust filter horizontal, galvanized: Dust filter horizontal, stainless steel: Dust filter vertical, stainless steel: Galvanized filter housing incl. filter element, diameter 355 mm, butt end connector for horizontal installation, foldaway clamp to connect filter outlet to CP inlet. Stainless steel filter housing incl. filter element, diameter 355 mm, butt end connector for horizontal installation, foldaway clamp to connect filter outlet to CP inlet. Stainless steel filter housing incl. filter element, Ø 355, butt end connector for vertical installation, incl. frame for filter housing, 90 elbow Ø 355, 2 fold-away clamp to connect filter element. Photo showing CLEAN-PROTECT with inlet dust filter for vertical connection. Though specifications for this and other non-standard configurations are not provided in this document, we will be pleased to advise you regarding your individual installation requirements. 4

Technical Data CLEAN-PROTECT Series System Specifications Series Models CLEAN-PROTECT CP500SF, CP1000SF 1 Connection for gas outlet φ 355 mm (14 in), butt end; flow for CP500SF: < 1800 m 3 /h (1060 foot 3 /minute) flow for CP1000SF: < 3600 m 3 /h (2120 foot 3 /minute) 2 Differential pressure displays 0...500 Pa (display for pressure drop over pre-filter) 0...2 kpa (display for pressure drop over pre-filter + absorber) 3 Pre-filter (particle filter) material of housing: stainless steel (different material on request); dimensions: 1100mm x 670mm x 670mm (43.3in x 26.4in x 26.4in) filter type: bag filter, GU-4-5 EU4) 4 Connection for gas inlet φ 355 mm (14 in), butt end; flow for CP500SF: < 1800 m 3 /h (1060 foot 3 /minute) flow for CP1000SF: < 3600 m 3 /h (2120 foot 3 /minute) Model H W D CP500SF 1660 mm (65.35 in) 2370 mm (93.30 in) 1200 mm (47.24 in) CP1000SF 2450 mm (96.45 in) 2370 mm (93.30 in) 1200 mm (47.24 in) Weight with heaviest filling Pressure build up at max. flow Lifetime of absorber filling 1000 kg (2205 lb) for CP500SF 1600 kg (3527 lb) for CP1000SF 6...11 mbar (0.09...0.16 psi) for CP500SF 7...12 mbar (0.10...0.17 psi) for CP1000SF 5 years, if no contact with toxic gas after contact with toxic gas, the filling is to be exchanged to get ready for use again 5

Technical Data CLEAN-PROTECT Series On-site Conditions for System Operation Temperature range Humidity Installation site Altitude 5...35 C (41...95 F); for special setups and applications a range of up to -28...+60 C (-18...+140 F) is possible 80 % relative humidity (non-condensing!) indoors, illumination > 270 lux, mechanical ventilation or outdoors (protected from unauthorized access) max. 2000 m (6600 ft) above sea level Floor space absolutely level; according to DIN 18202 Contact the manufacturer AG for further details on outdoor installation. Space requirement for installation and refill The CLEAN-PROTECT safety absorber is to be refilled on site. Space is needed for a pallet jack or forklift truck as well as a platform ladder. Model h w w d CP500SF 3550 mm (140 in) 600 mm (24 in) 2400 mm (95 in) 3300 mm (130 in) CP1000SF 4250 mm (168 in) 600 mm (24 in) 2400 mm (95 in) 3300 mm (130 in) 6

AG Fraunhoferstrasse 4 85737 Ismaning, Germany Phone: +49 (89) 96 24 00-0 Fax: +49 (89) 96 24 00-122 E-mail: General: welcome@csclean.com Distribution: sales@csclean.com URL: www.cscleansystems.com