Pneumatic Target Transfer System Model PT01

Similar documents
INSTRUCTION MANUAL Pressure Relief Device LPT

SG33KTL-M Quick Installation Guide. 1 Unpacking and Inspection

SG36KTL-M Quick Installation Guide. 1 Unpacking and Inspection

Installation, operating and maintenance Instructions for Seemag bypass level indicator

MUELLER. A Wall Type. Indicator Post. Reliable Connections. General Information 2. Technical Data/ Dimensions 3. Installation 4-5.

[Instruments for vacuum measurement, checking and adjustment] 3

Model 6810A Dual Lane Scoreboard Owner s Manual Rev B

Slit Valve. XGT Series. Low particle generation. With end lock mechanism. Service life of two million cycles. XLA XL XL Q D- XSA XVD XGT CYV

MUELLER. A A Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.

MoveRoll Conveyor Operating and Maintenance Manual

CONDUCTIVITY POINT/S LEVEL SWITCH JAYCEEAQUA 4000 SERIES

RPS900W Redundant Power Supply. Installation Guide.

HS653 Negative Pressure Ventilation Controller

OptiAir CA09 Pneumaticfluidizing

38999 Space grade ESA/SCC Section. MIL-DTL Space Grade Circular Connectors

TA-FUSION-P. Combined control & balancing valves Pressure independent combined balancing and control valves with independent EQM characteristics

MULTIFUNCTIONAL CONTROL FOR GAS BURNING APPLIANCE

MUELLER A A Non-Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.

Supplementary Operator s Manual 42/24-14 EN Rev. 3

SCAM T.P.E. WATER TREATMENT SYSTEM SWT- AP AUTOMATIC PURGE

ATH 500 M. Pumping speed ATH 500 M. 3.1 Vacuum generation / Turbopumps / Magnetically levitated / ATH 500 M. Page 398 / Part 3.1

BUBBLER CONTROL SYSTEM

SPECIFICATIONS ATTENTION

Operating Manual VSA100A. tina29e1 ( )

Sensor for Air Bubble Detection at Liquid Filled Tubes. SONOCHECK Type ABD06.xx. Operating Manual

Model 6812C Dual Lane Scoreboard Owner s Manual

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

System Pressure Manager Standard & System Pressure Manager Plus

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

I.H.S INSTALLATION INSTRUCTIONS

Hand lever valves VHER

RG2 Gripper Datasheet Version 1.6

UniSas BA. Physical single-person detection. Models: UniSas BA9, UniSas BA12. Energy savings. Eco-design. Recyclable product. Manual Attack Resistance

TANDEM MODULATOR FOR OUTLET GAS FLOW: STEPPED (836 TANDEM) - CONTINUOUS (837 TANDEM) SERVO-CONTROLLED PRESSURE REGULATOR

Pneumatic spool valve islands

Automatic Twin Greasing System

BUBBLER CONTROL SYSTEM

CompacSas BA. Comfort and design for high-security access

Levitronix LEVIBOOST 75 or 140. up to 75 or 140 l/min up to 20 or 37 gpm MANUAL

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

OEM Manual MODEL 2305 ECONOMICAL DIGITAL SINGLE CYLINDER SCALE

MULTIPOL - VDMA. PNEUMATIC SPOOL VALVE ISLANDS VDMA ISO 02 - ISO 01 (G1/8 - G1/4) designed for connection to a PLC by multiwire cable

4/2 way Pneumatic Solenoid Valve

Safety Standards. of the Nuclear Safety Standards Commission (KTA)

PART 1 GENERAL..2 Components of the gas chlorination system include, but are not limited to the following:

O P E R ATING INSTRUCTIONS FOR MODEL SPR-45 Automatic Screen and Stencil Printer

AutoChanger Installation & User Guide Issue 2

RAM 4021-DPX Operation Manual

AUTOMATIC GAS MANIFOLDS

Misaligned Folds Paper Feed Problems Double Feeds Won t Feed FLYER Won t Run iii

CCT-7320/ROC-2313 Reverse Osmosis Controller

Instruction Manual. PLT Series. 1. General Specification. 2. Installation. 3. Wiring. 4. Function. 5. Setting & Calibration

Pressure switch Type BCP

AREA VALVE SERVICE UNITS

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 09.14

Installation and operating manual. Pneumatic control station LK product no: PCS 1-10

Flamco Flamco-Fill STA Flamco-Fill STM

Pressure switches for air and water CS

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

TANK MANAGER FOR TWO TANKS OPERATING MANUAL. 10/31/11 C-More T6C L color touch panel

Instruction and Maintenance Manual

Mass Flow Controller (MFC) for Gases

Radiation Safety Program Manual Part 3 Cyclotron - Isotope Production

9A5N Solid State CW Paddle

Instruction and Maintenance Manual

Series P48. Pressure Controls for Steam, Air or (hot) Water. Product Bulletin. Generous wiring space provided. Splash-proof enclosure (IP54)

Parallel Seal Type Slit Valve

TECHNICAL CHARACTERSTICS

Chapter 2 Rigging. Cutting Wire Rope. Anchoring Wire Rope to Drum. Winding Wire Rope Onto Drum

RAM Operation Manual

Model 130M Pneumatic Controller

TECHNICAL DATA. Q = C v P S

NEW TYPE M PRESSURE RELIEF DEVICE

Valve Proving System VDK 200 A S06*

Single and double acting, magnetic, self-centering Bores: ø 16, 20, 25, 32, 40 mm

BERMAD Waterworks. Level Control Valve with Altitude Pilot. 700 Series. Model X. Features and Benefits. Major Additional Features

Columbus Instruments

VR46.5V(A)/VR86.5V(A) SERIES

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

INSTRUCTION MANUAL. FLOW CONTROL DRAWERS MANUAL / PLC CONTROL SERIES Model Version Perma Pure LLC Tel:

SM6. instructions for use. connection with compartment for incoming cable from the top. MV distribution factory built assemblies at your service

Pneumatic high-pressure controller Model CPC7000

SKP Series SKP25 U.. Pressure Regulating Gas Valve Actuator with Safety Shut-off Function

ASSE International Product (Seal) Listing Program

Miniature controls. Contactors. Overload relays. Starters. Control relays

Dual Solenoid Gas Valve Installation

Gas Pressure Switch for DMV safety shutoff valves

Tightness control TC. Product brochure GB 3 Edition AGA

Metham Aviation Design Limited, Station Approach, Four Marks, Alton. Hants. GU34 5HN Tel +44 (0) Fax +44 (0)

Depth sensor. Product reference : REV 1. USER GUIDE and INSTALLATION GUIDE. nke Sailing competition

Micro grippers HGPM/HGWM

Air Plus User Manual

Pegasus Series Amphenol Pcd

Data sheet Pressure switch type CS December 2001 DKACT.PD.P10.A B1119

Auxiliary valve QDS6 Sequence valve, 3-way. Catalogue (GB) (US) October 1998

KMW3000C. User Manual. Water Chiller for Xcalibur and Gemini systems. Version 1.6, September 2010

The Limit Switch with Better Seal, Shock Resistance, and Strength. General-purpose Limit Switch. Model Number Structure

Mass Flow Controller (MFC) for Gases

T i m i n g S y s t e m s. RACEAMERICA, Inc. P.O. Box 3469 Santa Clara, CA (408)

36E DSI, HSI & Proven Pilot Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

Transcription:

Pneumatic Target Transfer System Model PT01 Technical Data Sheet ELEX Commerce LLC Bul. M. Pupina 10Z/IV 11070 Belgrade, Serbia www.elexcomm.com February 2018.

Page 2/13 REVISION HYSTORY No. Description Made by Date 1. Modifications made reflecting the Rev. 2 of the system J. Čomor 2016/04/18 2. Communication between PTS and ACS described in detail J. Čomor 2018/02/22 VALIDATION HISTORY Created by Verified by Validated by Name: Jožef Čomor Đuro Jovanović Jožef Čomor Date: February 22, 2018 February 22, 2018 February 22, 2018 Signature: ELEX Commerce LLC Bulevar Mihajla Pupina 10Z/IV, p.p. 29 11070 Belgrade, Serbia Phone/fax: +381-11-311-5239 E-mail: office@elexcomm.com ELEX Commerce has an established Quality Management System according to ISO 9001:2015 standard Copyright 2018 ELEX Commerce LLC. All Rights Reserved. The unauthorized use, copying or distribution of this document may result in severe criminal or civil penalties, and will be prosecuted to the maximum extent allowed by law.

Page 3/13 Short description of the system PT01 is a fully automatic pneumatic target transport system, which provides for oneway transfer of solid target disks irradiated in the Nirta Solid Compact target station into hot cells for further radiochemical processing. The system uses a powerful blower for generating under-pressure, which transfers the sealed and locked capsule with the target disk. This way the system is inherently safe, i.e. radioactive particles released from the target cannot enter the atmosphere of the installation. The system has four main sub-systems: the robotic target handling station, the control cabinet with the PLC-based control and safety system, the blower station and up to five airlocks for inserting the capsules with the target disks into the hot cells. The control system of the pneumatic transfer system can be integrated into the control system of the cyclotron. Specifications of the pneumatic target transport system Target disk dimensions Max. Ø24 2 mm Disk material Platinum, silver, copper, etc. Number of receiving hot cells Max. 5 Maximum distance from the target station to the hot cell 35 m Mode of operation Automatic, semi-automatic and manual Built-in safety and interlock functions YES Dimensions and weight Size (W D H) Weight Robotic target handling station 63 51 140 cm 35 kg Control box 50 50 20 cm 10 kg Blower station 65 70 38 cm 25 kg

Page 4/13 Dimensions and weight Size (W D H) Weight Airlock 28 28 100 cm (of these 100 only 37 cm is in the hot cell) 10 kg Power requirements Voltage (VAC) Current (A) Control box 220 240 (50-60 Hz) 6 Site requirement specifications General specifications The following terms and conditions should be fulfilled for a successfull installation: 1. The local shielding around the airlock (located below the hot cell) and the tube for the rabbit (layed down in trenches) is not supplied by ELEX. The required lead bricks should be provided by the end user or the supplier of the hot cell. 2. The local shield around the airlock and transfer tubes should be built from min. 50 mm thick lead bricks. 3. The dimensions shown are the minimum internal dimensions within the local shield. The actual local shield can be bigger (and thicker). 4. The airlock (below the hot cell) and the receiving station (inside the hot cell) are to be installed on the same flange welded to the bottom of the hot cell s internal containment. Sufficient space should be provided around the receiving station inside the hot cell and through the opening through the shielding of the bottom of the hot cell. The flange on the bottom of the hot cell should be welded to the containment of the hot cell prior to the installation of the transfer system. 5. The local shielding around the airlock bellow the hot cell should be well fixed, in order to prevent that it collapses in case of an earthquake. 6. The receiving station shall be directly accessible by the right ball-tong manipulator. There should be no equipment placed in front of the receiving station (i.e. between the ball tong and the receiving station). 7. The receiving station shall be clearly visible through the lead window on the front side of the hot cell. 8. The control system of the hot cell shall provide an interlock signal in form of a dry relay contact with the following functionality: a. CLOSED CONTACT means the hot cell is ready to receive the rabbit; b. OPEN CONTACT means the hot cell is not ready to receive the rabbit. 9. This relay should be of normally open type, i.e. in case of power failure it shall provide an open contact. 10. For the connection of the airlock it is necessary to weld a flange onto the floor of the inner containment of the hot cell as specified on the following drawings.

Page 5/13 11. There should be an opening in the lead shielding bellow the floor of the hot cell around this flange as indicated in the following drawings. This opening can be circular or square. 12. The distance from the lower face of the containment of the hot cell to the floor and from the lower face of the lead shielding to the floor shall be communicated to ELEX as early as possible. 13. The control system of the target transfer system should be integrated into the control system of the cyclotron through a number of relay input/output contacts as explained at the end of this TDS. General layout of a typical facility The robotic target handling station installed below the target station

Page 6/13 Robotic target handling station Target transport capsule (self-locking type) Drawing explaining how to weld the flange to the bottom of the hot cell s containment (the orientation of the tapped holes (not visible in this cross section) is irrelevant, since the receiving station can be continuously rotated around the central axes of the flange before fixing it by 8 M10 bolts

Page 7/13 Production drawing of the flange to be welded to the bottom of the containment of the hot cell for the installation of the receiving station (all dimensions are in mm)

Page 8/13 Sectional view through the hot cell showing the position of the receiving station in the containment of the hot cell as well as the location of the airlock with the corresponding lead shielding Positioning of the flange for the installation of the receiving station: horizontal sectional view through the hot cell (the dimensions are indicating the distance between the center of the flange to the inner walls of the hot cell; the receiving station should be positioned into the right-rear corner of the containment)

Page 9/13 Building the lead shielding around the airlock below the hot cell. The dimensions are indicating the minimum space required for the airlock. The shielding can be easily built from standard lead bricks using standard-size components. Docking stations Capsule The target receiving station. Left: closed, right: open station (the capsule is visible after it arrived into the station). The caps can be removed by hanging the capsules in the dedicated recess and pulling the body downwards. The target disk can be poured out from the capsule into the funnel, from which it can be grabbed by the ball-tong manipulator. There are two docking stations for turning the target disk up-side-down.

Page 10/13 Disposition and dimensions of the blower station, shielded trench for tubing and control cabinet The control cabinet should be connected to the control system of the cyclotron (Accelerator Control System, ACS) in order to integrate the operation of the pneumatic target transport system into the control software of the cyclotron. This will allow to the cyclotron operator to initiate the transfer and to visualize the status of the transport system on the control screen of the cyclotron. There is a dedicated connector on the bottom of the control cabinet, which can be used to connect the cable, which can be laid-down between the two systems. The following drawing provides all relevant information for making such a cable (not in the scope of delivery of the pneumatic transport system) and it describes also the functionality of the communication between the two systems.

Braid W-9 W-10 W-8 W-7 W-6 W-5 W-4 W-3 W-1 W-2 W-1-9 W-1-10 Reserve GND W-1-8 W-1-7 W-1-6 W-1-5 W-1-4 W-1-2 W-1-1 +24 VDC Page 11/13 INIT_DISK_TRANSFER=true/false (100 ma max.) DISK_RELEASED=true/false (100 ma max.) Closed contact: PTS is ready to receive the disk (READY_TO_RECEIVE_DISK=true) Maximum permitted resistive load: 2 A @250 VAC, 1 A @ 30 VDC Closed contact: PTS is operational (SYSTEM_OUT_OF_ERROR=true) Maximum permitted resistive load: 2 A @250 VAC, 1 A @ 30 VDC Closed contact: capsule is in transit (CAPSULE_TRANSFER_IN_PROGRESS=true) Maximum permitted resistive load: 2 A @250 VAC, 1 A @ 30 VDC W-1-3 +24 VDC Control System of the Pneumatic Transport System (PTS) Female square flange receptacle, 12 pin #16 (UTG01412S, Souriau 12 RC24M9K, Souriau) ACS-X4 M L K J H G F E D C B A Accelerator Control System (ACS) ACS+X3 Male cable plug, 12 pin #16 (UTG61412PN, Souriau 12 RM24M9K, Souriau UTG14PG, Souriau) M L K J H G F E D C B A Cable provided by the cyclotron vendor: LiYCY, 10 0.25 mm 2 ACS-C Shortcut: Capsule is in transit (CAPSULE_TRANSFER_IN_PROGRESS=true) This signal is for the building management system (BMS) or for the radiation protection safety system Shortcut: PTS is operational (SYSTEM_OUT_OF_ERROR=true) Shortcut: PTS is ready to receive the disk (READY_TO_RECEIVE_DISK=true) Closed contact: Target released from target station (DISK_RELEASED=true) Closed contact: Initiate disk transfer (INIT_DISK_TRANSFER=true) Braid W-10 W-9 W-8 W-7 W-6 W-5 W-4 W-3 W-2 W-1 Specifications of the communication cable between the control system of the pneumatic transport system (PTS) and the control system of the cyclotron (ACS).

Page 12/13 The control system of the pneumatic transport system can also communicate to individual hot cells. In order to prevent that radioactive material is sent into the hot cell while it is not ready for safely receiving radioactive materials (e.g. the shielding door is not closed, the under-pressure in the containment is not appropriate, there is already too much activity in the hot cell, etc.) the delivery of the capsule into any of the hot cells can be interlocked by a safety interlock provided by the hot cell s safety system. Such an interlock should be a dry contact (e.g. relay contact), which status will be understood by the control system of the pneumatic transport system in the following way: OPEN CONTACT: the hot cell is not ready to receive the capsule. CLOSED CONTACT: the hot cell is ready to receive the capsule. This contact, provided by the hot cell, can be transmitted to the control system through a dedicated screw-in-wire connector one can find on each airlock. Using a two-wire cable one should connect the relay contact of the safety system of the hot cell to pins 1 and 2 of the connector on the airlock, as indicated in the following drawing. Control system of the pneumatic target transport system (PTS) Dry switch HCY.OK Safety system of the hot cell: closed dry contact means the hot cell is ready to receive the target (doors and airlocks closed, ΔP lower limit) HCY.OK-C External system in responsibility of the end user +24 VDC +24 VDC IRRY.4-X1 IRRY.4+X2 1 1 2 2 3 3 4 4 5 5 6 6 HCY.EN-C Dry switch HCY.EN Safety system of the hot cell: closed dry contact means the hot cell should be treated as enabled for the pneumatic target transport system 1825543 (Phoenix) 1852066 (Phoenix) 1778027 (Phoenix) External system in responsibility of the end user HCY.AL-C HCY.OK=true/false (100 ma max.) HCY.EN=true/false (100 ma max.) Open contact: Airlock alarm condition (HCY.AL=true) Maximum permitted resistive load: 2 A @250 VAC, 1 A @ 30 VDC HCY.AL Safety system of the hot cell: open contact means there is an alarm condition in the capsule receiving station inside the hot cell External system in responsibility of the end user NOTE: In every annotation Y denotes the ident. number of the hot cell in which the target receiving station is installed. Valid numbers are 1-5. Schematics of the interconnection of safety interlocks between the hot cell and the pneumatic transport system.

Page 13/13 The control system of the pneumatic transport system provides one more useful feature. Namely, in case the hot cell is out of operation for certain time (during service and maintenance or breakdown), it can be completely excluded from the operation of the transport system with a second interlock. This interlock signal (dry contact) could be provided by a key operated switch mounted onto the operating panel of the hot cell. The status of this contact will be understood by the control system of the pneumatic transport system in the following way: OPEN CONTACT: the hot cell is not available exclude it from the list of available hot cells. CLOSED CONTACT: the hot cell is available include it into the list of available hot cells. This safety interlock (hot cell available/not available) can be connected to the same connector of the airlock, using pins 3 and 4 as indicated in the previous drawing. Finally, the control system of the pneumatic transport system is providing a dry contact to external users (systems), which can be used as an alarm signal. Namely, if the airlock of the capsule receiving system is malfunctioning and the safety system detects the situation that the door of the receiving station is open and at the same time at least one of the ball valves of the airlock is not closed, the control system will activate a relay and open a dray contact, which is connected to pins 5 and 6 as indicated in the previous drawing. This open contact between pins 5 and 6 can be used by the safety system of the hot cell for instance to activate an alarm (audio and/or visual alarm). Indicating that the tightness of the hot cell is compromised.