ALTERNATIVE INSTALLATION PROCEDURES FOR 90 AND 45 KTKK MOULDED PART AND ADAPTOR ASSEMBLIES

Similar documents
INSTALLATION PROCEDURES FOR COATED RAYATEN MOULDED PARTS ONTO D-SUBMINIATURE CONNECTORS

PREPARATION & APPLICATION OF S1125 ADHESIVES

VARIABLE TEMPERATURE HOT AIR GUN VALIDATION

The Outer Seal is highly abrasion resistant and provides mechanical stiffness to the splice in order to better match the cable stiffness.

Teledyne Oil & Gas North Williamson Blvd. Daytona Beach, FL USA (phone) (fax)

ESA Elbow Sealing Adapter Kit

Gas Lines. Technical Manual. Sumitomo (SHI) Cryogenics of America, Inc Vultee Street Allentown, PA U.S.A.

COOPER POWER SERIES. 200 A 15/25 kv class deadbreak straight connector installation instructions. Deadbreak Apparatus Connectors MN650043EN

FOSC-400B4-MC-X06-X-NV

COOPER POWER SERIES. DS250 deadbreak straight connector installation instructions interface A. Connectors MN650027EN

Any tool, at the ready. 3M DBI-SALA Fall Protection for Tools Pocket Reference Guide

Any tool, at the ready. 3M DBI-SALA Fall Protection for Tools Pocket Reference Guide

Roofing Primer. Primer 610 Spray PRODUCT DESCRIPTION PRODUCT DATA. Spray Applied Primer for use with S-Vap 7000 E DP & Decostik SP

PRODUCT SPECIFICATION. SFP+ Cage and Cage Assembly 1 of 8 A

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

Technical Data Sheet PART A & PART B

INSTRUCTION MANUAL MP4AR Remote Convection Gauge Range: 1 x 10-3 Torr to 1 x 10+3 Torr

COOPER POWER SERIES. 200 A 15/25 kv class elbow installation instructions. Deadbreak Apparatus Connectors MN650042EN

COOPER POWER SERIES. DE250 deadbreak elbow connector installation instructions interface A. Screened Separable Connectors MN650025EN

Roofing Adhesive PRODUCT DESCRIPTION PRODUCT DATA. Spray Applied Insulation Adhesive for Sarnafil Roofing Systems

E X R A D I N Spherical Ion Chambers A3. A4 REF DOC #

Angled Sign Light with Shade

DT400/436 Tee Connector Installation Instructions

3M Liqui-Cel EXF-14x28 and 14x40 Series Membrane Contactor

Instruction Manual. Model TC1-S TopSide Clamp. top side clamp. For your personal safety READ and UNDERSTAND instructions before using tools.

200 A, 15 and 25 kv class loadbreak bushing insert installation instructions

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

2-1- Shipping Receiving Lifting Location on Site Installation Stages 6

TDUX Inflatable Duct Sealing System 1.0 General Product Information

Damage Control/Luminous Shipboard Markings

3M Liqui-Cel EXF-4x13 and 4x28 Series Membrane Contactors

INSTALLATION COMMISSIONING, OPERATION & MAINTENANCE MANUAL

Operating Instruction English. Revision A Date author NH This operating instruction is not subject to updating. Airgun

OPERATING and MAINTENANCE INSTRUCTIONS MAXIS Grips

APPLICATION NOTE AN-2100 PREVENTIVE MAINTENANCE OF FIBER OPTIC CABLES AND FINISAR OPTICS

ULTRA-LIGHT DUTY ONBOARD AIR SYSTEM

SOTR Special Operations Tactical Respirator

Operator s Manual 701 Test Kit for Static Control Surfaces (Megohmmeter)

Cleaning rod: spring steel, stainless steel or carbon fibre cleaning rod - only use a one-piece rod. Avoid using snakes.

Avery Dennison Instructional Bulletin 1.4 Application Methods for Pressure Sensitive Adhesive Films

FLANGED MULTI-PORT BALL VALVES

32374 R. Jazowski 4/4/ D. W. Mudge G. Sivik 1 of 8 ODN TITLE: Installation & Operation Manual for Nautilus G2 Connectors

Any tool, at the ready. 3M DBI-SALA Fall Protection for Tools Pocket Reference Guide

3M Liqui-Cel EXF-10x28 Series Membrane Contactor with ANSI or JIS Connections with Integrated End Caps

Hardener: at least 24 months when stored cool and dry

Instruction Manual LIMITED 1 YEAR WARRANTY. Hydraulic Punch Driver Read this material before using this product.

Model SM/PL Series. Calibration Guide. Precision Loads. Anritsu Company 490 Jarvis Drive Morgan Hill, CA USA

Size Selection & Installation of QSZH-125

1.0mm PITCH I/O CABLE IDT TOOL

Instruction Manual. PE Pipe Squeeze-off Tool Model TR650

Hot Tapping Machine. OPERATIONS MANUAL and OPERATING INSTRUCTIONS

FLANGED TWO-PIECE BALL VALVES

Owners Manual MAX-10/45 Upper Receiver. Rev. A. NFA Warning. LAGE Manufacturing, L.L.C. 916 E. Baseline Rd. STE #113 Mesa, AZ 85204

DRAFT DRAFT Version: March 25, 2008

Floor Mount Socket. T: +44 (0) F: +44 (0)

Operating Instructions

How to terminate an F/UTP CAT 6 cable with the LP-LRJ458P8CC6FS21 Plug.

Congratulations on your purchase of a JC Series Performer trike! The Performer JC Series is designed for everything from touring to commuting and

Status Date Prepared Reviewed Endorsed Approved

TECHNICAL MANUAL DHR80 LED. Den Haan Rotterdam MED96/98/EC

3M Liqui-Cel EXF-10x28 Series Membrane Contactor

Agilent 1290 Infinity Pump Head Maintenance

12 Inch Barn Light. Owner s Manual

AGM 33 PIKE ALL FIBERGLASS. Specifications Length: 92 Diameter 5.5 Weight: 24 lbs Motor Mount: 75mm Fins: 6-3/16 G10 CP: 68 from nose tip Parts List

Vevazz. Operation Manual. Vevazz, LLC Rancho California Road. Suite Temecula, CA Phone: (773) Fax: (888)

Titanium Powder Safety Data Sheet

OKLAHOMA CITY COMMUNITY COLLEGE PERSONAL PROTECTIVE EQUIPMENT PROGRAM. Environmental Health and Safety

airplaine kite Model assembly & Operating Instructions Important: If damage is caused due to a crash; your warranty is void.

Arbor Terminator Press Operation Manual For IDT Connectors Order No Engineering No: AM

COOPER POWER SERIES. 600 A 35 kv class PUSH-OP deadbreak connector installation instructions. Deadbreak Apparatus Connectors MN650052EN

FLANGED TWO-PIECE BALL VALVES

DP40 is a versatile 2K Epoxy Surfacer. It is light grey in colour, chromate-free and has good corrosion resistance over bare metal.

3 Scotch-Weld Polyurethane Reactive Adhesive Applicator Replacement Part Installation Guide

Transmitter CS 21 Operation Manual

May08 Rev B

PERFORMANCE SPECIFICATION HARNESS AND CABLE ASSEMBLIES

Vertical Lifeline. Ladder Climb. User Instructions. 3M Occupational Health and Environmental Safety. Fall Protection Equipment

PVC Quick Drain Valve

Calcium Safety Data Sheet

E X R A D I N. Parallel Plate Ion Chambers User Manual DOC #

Installation and Operation Manual

Instruction Manual AC350 GUIDED-TYPE FALL ARRESTER ON RIGID ANCHORAGE LINE EN 353-1:2002

NeoNatalie Resuscitator Oxygen kit

APT Electrofusion Ducting

600 A 35 kv class PUSH-OP deadbreak connector installation instructions

Test Report No Insulguard Fire Resistance Enclosure. Insulguard Australia Bentleigh, Victoria

TECHNICAL MANUAL DHR60 LED. Den Haan Rotterdam MED96/98/EC

DEPARTMENT OF DEFENSE TEST METHOD STANDARD METHOD 215, RESISTANCE TO SOLVENTS

COOPER POWER SERIES. D-73P3 bypass switches installation instructions. Switches MN008005EN. Effective April 2016 Supersedes S June 2013

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

275 RID Assembly Instructions

Hygienic Bubble Trap Installation and Operations Manual

Effective May 2017 Supersedes July 2009 (S ) 600 A 35 kv Class T-OP II connector assembly installation instructions 200 A PROTECTIVE CAP LRTP

TITAN FLOW CONTROL, INC.

Accu-Tab Systems 1000 Series by Axiall Corporation

Accu-Tab Systems 2000 P Series by Axiall Corporation

Compatible with Desothane HS topcoats Excellent adhesion and corrosion resistance Service temperature -54 C to 177 C (-65 F to 350 F)

S&S. Installation Instructions: S&S Stealth Air Cleaner Kit for Harley-Davidison Models With Stock Cable Operated Delphi EFI

3.1 T AND TKH FERRULES EUROPEAN STANDARD SYSTEM EN

Pre-filter for Brushless Blower Instruction Manual

Transcription:

Rayaten Moulded Parts Installation Procedures Code of Practice ELE-3COP-524 23 rd Mar 2018 Class I ALTERNATIVE INSTALLATION PROCEDURES FOR 90 AND 45 KTKK MOULDED PART AND ADAPTOR ASSEMBLIES ELE-3COP-524 TE Connectivity s 90 and 45 KTKK Moulded Part / Adaptor Assemblies ELECTRONIC APPROVAL, NO SIGNATURES WILL APPEAR. IF PRINTED THIS DOCUMENT BECOMES UNCONTROLLED Before starting work please read this document carefully and note the guidance given.

1. PURPOSE AND SCOPE This Code of Practice describes the procedures to be used when installing 90 and 45 KTKK moulded part/adaptor assemblies from TE Connectivity (TE). The instructions stated in this document take preference over IPC/WHMA requirements, as do the drawing and any customer documentation. It is good working practice that where trained operators have not installed this product for over 6 months, a sample installation should be carried out by the operator to refresh installation practice. Performance of the sample can be checked using the inspection standards described within this document. Page 2 of 14

TABLE OF CONTENTS 1. PURPOSE AND SCOPE... 2 2. PERFORMANCE OBJECTIVE... 4 3. MATERIALS AND EQUIPMENT... 5 4. HEALTH AND SAFETY... 6 5. PROCEDURE - PREPARATION... 7 6. INSPECTION REQUIREMENTS... 12 7. VISUAL STANDARDS... 13 8. REVISION HISTORY... 14 Table of Figures Figure 1 Degreased and abraded cable jacket... 9 Table of Tables Table 1 Cut back length... 7 Table 2 Post heating times... 10 Table 3 Revision history... 14 Page 3 of 14

2. PERFORMANCE OBJECTIVE ELE-3COP-524 This code of practice is produced to support operators already trained in the installation of heat shrinkable and harnessing products. It identifies an alternative procedure which may be used when installing 90 and 45 KTKK moulded part/adaptor assemblies for all screened and unscreened assemblies with preinstalled adhesive on J end of boot (Method 1), and all coated and uncoated assemblies without pre-installed adhesive on J end of boot (Method 2). Page 4 of 14

3. MATERIALS AND EQUIPMENT Appropriate 90 or 45 KTKK Moulded part/adaptor Assembly. Raychem S1125 adhesive (Method 2 only). Raychem S1184 adhesive (Method 2 only). P100 grit Emery Cloth or equivalent. Degreasing Agent isopropyl alcohol or isopropanol (IPA) impregnated tissue wipe. Heavy duty tissues. Heat Gun CV1981 or equivalent. Other hot air guns may be used but these must be capable of delivering the temperatures required for installation of the Rayaten Moulded Part. This also includes hot air guns with temperature displays. Reflector PR-24, PR-26 or equivalent. Bend Test Fixture 500Z1270 (TE Connectivity). Heat Resistant Gloves. Safety Glasses. Page 5 of 14

4. HEALTH AND SAFETY ELE-3COP-524 Adhere to local Codes and Regulations relating to Safe Working practices. For the UK, adhere to requirements of the Health and Safety at Work Act 1974 and subsequent amendments. The installation should be carried out in a well-ventilated area. Always wear heat resistant safety gloves when handling hot plastics and adhesives. The use of suitable protective gloves and barrier cream is recommended when using solvents. Avoid prolonged repeated skin contact with solvents and always wash hands after using solvents. Care should be taken to wear safety glasses when using and handling chemical solvents. If eyes do become contaminated, flush with water and obtain medical assistance immediately. Always ensure all equipment is calibrated before use. Page 6 of 14

5. PROCEDURE - PREPARATION This procedure covers two methods: Method 1 - For all screened and unscreened assemblies with pre-installed adhesive on J end of boot, ignore steps 5.1, 5.10, 5.11 and 5.13. Method 2 - For all screened and unscreened assemblies without pre-installed adhesive on J end of boot, include steps 5.1, 5.10, 5.11 and 5.13. 5.1. (For screened and unscreened) METHOD 2 ONLY. Degrease the uncoated J end of the moulded part and abrade with P100 grade emery cloth. Remove any loose particles with a dry tissue. Take care not to abrade coated area. 5.2. (For screened and unscreened) Slide the KTKK assembly onto the cable. 5.3. (For screened and unscreened) Cut back the cable jacket sufficiently to terminate the conductors to the connector. The recommended dimensions depend upon the size of the moulded part and are given in Table 1 (Dimension L). Allow an extra 20 mm for service loops if required. Fold back cable braid over cable jacket and temporarily secure. Table 1 Cut back length Moulded Part Size L (mm) A (mm) 222K132 38 20 222K142 40 25 222K152 40 25 222K163 50 30 222K174 70 30 222S121 38 10 222S132 40 10 222S142 45 10 222S152 50 12 222S163 65 20 222S174 80 20 Page 7 of 14

5.4. (For screened and unscreened) Terminate the conductors to the connector in the appropriate way. 5.5. (For screened and unscreened) Slide the KTKK assembly along the cable and temporarily secure it to the connector. Mark the cable where the moulded part ends. 5.6. (For screened and unscreened) Release the KTKK and slide it back along the cable. Make a second mark, distance A towards the connector, from that made in step 5.5. Distance A depends on the size of the moulded part and is given in Table 1 (dimension A). 5.7. (For screened) Pull down cable braid tight over the cable jacket and cut back to Mark 6. Page 8 of 14

5.8. (For screened) Secure the ends of the braid with the tinned copper wire, ensuring that the twisted ends are folded flat against the braid. 5.9. (For screened and unscreened) Degrease area A and the cable braid with the cleaning tissue provide. Thoroughly abrade area A with the P100 grit emery cloth and then remove any loose particles with a dry tissue. DO NOT use a solvent wipe. The whole surface of the cable jacket should be abraded removing any print on the cable jacket. See Figure 1. Take care to avoid abrading the plating of the braid. Figure 1 Degreased and abraded cable jacket This part of the cable preparation is very important in ensuring a strong bond to the moulded part. Page 9 of 14

5.10. (For screened and unscreened) METHOD 2 ONLY. Mix the S1125 adhesive, taking note of the approximate pot life of 60 mins at ambient temperature. 5.11. (For screened) METHOD 2 ONLY. Mix the S1184 adhesive and work into the length of the braid and thickness 2 mm. 5.12. (For screened and unscreened) With the major keyway in the correct position, secure the KTKK to the connector using the appropriate mating half and tighten to the specified torque value. Refer to ELE-3COP-452 5.13. (For screened and unscreened) METHOD 2 ONLY. Apply S1125 adhesive to area A on the cable jacket and to the uncoated area of the J end of the moulded part. 5.14. (For screened and unscreened) Using a CV-1981 Heat Gun set to 230 C to 250 C and with a PR24 or PR26 reflector, shrink the rear of the moulded part onto the cable. Heat must be applied evenly around the moulded part to recover evenly and prevent scorching. Ensure the part is fully recovered onto the cable. Look for evidence that adhesive is present and clean off excess adhesive. Post heat times shown in Table 2 should be adhered to in order to give sufficient bonding. Table 2 Post heating times Moulded Part Size Approx recovery time (secs) Post Heat time (secs) 121 30 90 132 30 120 142 45 135 152 45 150 163 60 165 174 60 180 Note: When using S1184 and s1125 adhesives the post heat times must be followed by a further 24 hours at RT, or 1 hour at 85 C, or 15 minutes at 150 C before handling. Page 10 of 14

Always ensure that the air vent on the rear of the hot air gun is open and that it is dust free. Always allow the hot air gun to stabilize at the required temperature and setting for two minutes before commencing calibration and installation. Hot air gun validation shall be carried out on a regular basis, frequency will depend on usage. Please refer to the Manufacturers guide for hot air gun calibration and maintenance and ELE-3COP-711 for hot air gun validation. For Screened Assemblies In order to verify correct installation, it is important that certain checks are carried out to ensure that there are no high resistance terminations. This can be done by recording the DC resistance of the braid prior to installation of the KTKK. Upon completion of installation of the KTKK assembly, the DC resistance value should not increase by greater than 2.5 milliohms. The measurement of DC resistance gives no statement about the screening performance of the harness, it only tells the quality of the termination. Page 11 of 14

6. INSPECTION REQUIREMENTS ELE-3COP-524 The termination should be rotated so it is subjected to a flex test of 90º in each of four planes around a mandrel with a diameter equal to 6 times the cable diameter. 90 There should be no separation between the Moulded Part and the cable jacket at the adhesive bond line. The Moulded Part must be free from fingerprints and scorch marks. Record DC resistance measurements. Page 12 of 14

7. VISUAL STANDARDS No visual standard currently available. Page 13 of 14

8. REVISION HISTORY Author Approved Date Rev Comments K. Carter P. White 30JUN1988 2 - P. Newman N. Dorricott 05AUG2010 3 CR09-DM-018 P. VU H. Smith 23MAR2018 4 Table 3 Revision history Plated Rayaten replaced by Coated Rayaten moulded parts RTS-1364475.1 All of the above information is believed to be reliable. Users, however, should independently evaluate the suitability of each product for their application. TE makes no warranties as to the accuracy or completeness of the information and disclaims any liability regarding its use. TE s only obligations are those in the Standard Terms and Conditions of Sale for these products and in no case will TE be liable for any incidental / indirect or consequential damages arising from the sale, resale, use or misuse of the product. TE s specifications are subject to change without notice. In addition, TE reserves the right to make changes in materials or processing, without notification to the Buyer, which do not affect compliance with any applicable specification. Page 14 of 14