REFERENCE SPECIFICATION FOR END

Similar documents
SOUTH AFRICAN NATIONAL STANDARD

Operating Instructions

Pressure Equipment Directive PED 2014/68/EU Commission's Working Group "Pressure"

Fiji Electricity Authority Transmission Unit 2 Marlow Street, Suva

GEMS SENSORS & CONTROLS

INSTALLATION AND OPERATING INSTRUCTIONS:

AIRMASTER SERIES RF AUTOMATIC DEWATERING VALVES. For the purging of water from compressed air systems WHERE DO YOU NEED AUTOMATIC DEWATERING VALVES

Specification For Water Meters. Pr10068

INSPECTION, TESTING AND CERTIFICATION OF GASFITTING WORK DONE UNDER SUPERVISION

Operating Instructions

Supersedes: The copy of this document located on Measurement Canada s website is considered to be the controlled copy.

Manual Power relay SR853

Miris Ultrasonic Processor

GUIDANCE FOR THE APPLICATION OF EQUIPMENT CALIBRATION AND TRACEABILITY OF MEASUREMENTS ON INSPECTION BODIES

Further technical information is available on

1. Introduction. The Easy Guide to TMV3 Approval

ASSE International Product (Seal) Listing Program

PERSONAL FLOTATION AIDS

Parts Manual. Spray Gun Series Master III. Issue /11/2017 Ref. NR ENG

SAFETY PRINCIPLES FOR PRESSURE REGULATORS FOR MEDICAL OXYGEN CYLINDERS

CCSSL35 Carry out the wiring and testing of electrical circuits and equipment

The SAG type flat, rubber-steel, balance ropes

GUJARAT STATE ELECTRICITY CORPORATION LIMITED

Technical Specifications (In-Cash Procurement)

CHOKER JOKER LIGHT CAMBIUM SAVER

Operating manual Mobile Man Anchor IM-200 Reference No. IM 200

ITTF APPROVED TABLES

3 Post Pressure Fit System Owner s Manual

INTERNATIONAL STANDARD

ITER_D_R8752R v.1.1. IDM UID D_R8752R v.1.1

GUNNEBO INDUSTRIES LIFTING SHACKLES

ISO INTERNATIONAL STANDARD. Personal protective equipment for protection against falls from a height Single-point anchor devices

Spring Loaded Safety Valves

Draft Indian Standard WIRE ROPE SLINGS AND SLING LEGS- SPECIFICATION (Second Revision) ICS ;

Loss Prevention Standard

SNOW PICKETS` Climbing and Mountaineering Equipment. Foreword

User Manual V14.1 IP68 LED FLEX NEON

For Department of CSSD

NIT LIMITED NO. NC-185-SCS-P-NOCB ARGON & NITROGEN CYLINDER WITH REGULATOR

Code of Practice for the Inspection and Testing of Portable Electrical Equipment (PAT)

Geopress. Instructions for Use. Year built: from 01/2004 en_int

SpanSet Gotcha CRD User Instructions. SpanSet Certified Safety

SUPPLY OF ISOLATION AND APPLIANCE VALVES PTS - APPLIANCE BALL VALVE

Guide to Documentation and Marking Part 5 Lifting Accessories, Slings

CERTIFICATION IMPACT ANALYSIS: IEC 60065, SEVENTH EDITION vs. GB Audio, video and similar electronic apparatus Safety requirements

CBMTG Laboratory Committee-Laboratory Guidance

SAFETY QUALITY TECHNOLOGY. Guidance on Safe Isolation Procedures

NIT LIMITED NO. RD-NC-40-SPS-PH

PECIMEN IMM6. Minor Electrical Installation Works Certificates. Amd 3: In accordance with BS 7671

LABELLING OF MEDICAL GAS CONTAINERS

Mounting instructions. Strain transducer SLB-700A. B 26.SLB700A.10 e

UIAA Standard (UIAA = Union Internationale des Associations d Alpinisme) January Mountaineering and Climbing Equipment. Connectors.

Metal Expansion Joints. System solutions for reliable connections in plant engineering and construction.

Flexible & Intelligent

INTERNATIONAL STANDARD

SUPPLY OF ISOLATION AND APPLIANCE VALVES PTS - ISOLATION BALL VALVE

Instructions for Use. Plug connection for medical gas and vacuum acc. to DIN / 2004 DIN EN ISO

POLICY FOR COSHH (CONTROL OF SUBSTANCES HAZARDOUS TO HEALTH) POLICY

THE BP-690 SERIES. Operating and Service Manual. Series includes all variants of BP-LF/MF-690/691

Check with local zoning official for property line distance requirements.

Guidance on the Legal Obligations for Importers, Retailers and Distributors of Category 1 Fireworks

International Civil Aviation Organization DANGEROUS GOODS PANEL (DGP) MEETING OF THE WORKING GROUP OF THE WHOLE. Montreal, 18 to 22 April 2005

NIT LIMITED NO. NC-105-P-SCS-NOCB CYLINDERS & REGULATORS

SOUTH AFRICAN NATIONAL STANDARD

ISO 5367 INTERNATIONAL STANDARD. Breathing tubes intended for use with anaesthetic apparatus and ventilators

ISO INTERNATIONAL STANDARD. Personal fall-arrest systems Part 1: Full-body harnesses

GGG-M-125/3A September 20, 1982 SUPERSEDING GGG-M-125/3 March 28, 1975 FEDERAL SPECIFICATION

Norrsken Family Booklet

ISO 5359 INTERNATIONAL STANDARD. Low-pressure hose assemblies for use with medical gases

IRATA International. Jonathan Capper Executive Chairman

TECHNICAL AND COMPLIANCE COMMITTEE Sixth Regular Session 30 September - 5 October 2010 Pohnpei, Federated States of Micronesia

Distribution Connection Forms

CONTRACTOR WHS HAZARD STANDARD HAZARDOUS CHEMICALS EXTERNAL USE ONLY

Part 3: Safety Rules for the Installation and Maintenance of Underground Electric Supply and Communication Lines

Good things come in threes

Gas Welding Hoses and connections, the weak link

OFFER INQUIRY NO. 02/07/2015

Pressure Equipment Directive PED 2014/68/EU Commission's Working Group "Pressure"

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401

Women s Division 2017

PULSAR 5000 SERIES OPERATING & INSTALLATION INSTRUCTIONS SERIES 5000 PLEASE READ CAREFULLY BEFORE INSTALLING

Requirements for the certification of movements and mechanical watches resistant to magnetic fields of 1.5 T ( G)

$ Plan Review Fee when Permit Application is submitted HOT TUBS AND SPAS BUILDING PERMIT APPLICATION. COST: $80.

DigiTRON Electrical Flying Leads, Jumpers and Harness Assemblies Site Received Test Manual

OCP TRF LIMITED (BMHE DIVISION)

Document Control Summary Status: Replacement for Electricity High Voltage SOP v1.0 Version: V1.1 Date: July 2017 Author/Title: Owner/Title:

Protector Aluminium Fencing and Balustrades

GOOD MANUFACTURING PRACTICE GUIDE PART I FOR MEDICAL GASES

SPOOL VALVES. pilot operated single/dual solenoid (mono/bistable function) ISO mm - pad mounting body M12 connection

Regulatory Compliance Mark

Respiratory protective devices

Assembly instruction. Operating temperature range -60 C +85 C Protection. IP 66, 67, 68 (5 bar)

TECHNICAL SPECIFICATION

Technical Data. Dimensions

Farm Animals Breeding Act 1

Operating Instructions VETTER Industrial Lifting Bags 8 bar - Type IKV

ASEAN STANDARD FOR SAPODILLA (ASEAN Stan 25:2012)

About. providing superior performance and reliability. Bromic regulators are AGA or UL144 approved.

e.do Gripper Safety requirements, technical features and assembly and integration instructions

CABLE ENTRIES IN HAZARDOUS AREAS CORRECT SELECTION, INSTALLATION AND MAINTENANCE

Transcription:

TITLE SPECIFICATION FOR END CONNECTORS AND INSULATING DATE: DECEMBER 2003 SLEEVES PAGE: 1 OF 18 TABLE OF CONTENTS Page FOREWORD... 2 INTRODUCTION... 3 1 SCOPE... 3 2 CONSTRUCTIONAL REQUIREMENTS... 3 2.1 End connector... 3 2.2 Insulating sleeve... 3 2.3 Size... 4 3 MARKING, PACKING AND DOCUMENTATION... 5 3.1 Marking... 5 3.2 Packing... 5 3.3 Documentation... 5 4 QUALITY MANAGEMENT... 5 5 TRAINING... 6 Annex A - Bibliography... 7 Annex B - Revision information... 8 Annex C - Item 1: END CONNECTOR NO. 2 SAP NO. 5510... 9 Annex C - Item 2: END CONNECTOR SLEEVE NO. 2 SAP NO. 5511... 12 Annex C - Item 3: END CONNECTOR NO. 3 SAP NO. 6233... 15 Annex C - Item 4: END CONNECTOR SLEEVE NO. 3 SAP NO. 6234... 18 Annex D Stock Items... 21

PAGE 2 OF 18 FOREWORD Recommendations for corrections, additions or deletions should be addressed to the: Technology Services Manager City Power Johannesburg (Pty) Ltd P O Box 38766 Booysens 2016

PAGE 3 OF 18 INTRODUCTION In order to provide a quick and electrically sound way of connecting cable cores together and insulating them the use of end connectors and insulating sleeves shall be specified for this use. 1 SCOPE This specification covers City Power s requirements for end connectors and insulating sleeves. 2 CONSTRUCTIONAL REQUIREMENTS 2.1 End connector 2.1.1 The end connector shall be: a) Of a standard size as to accommodate the cables used, b) Of a non-corrosive metal construction, c) Clean and free from any defects that may have a detrimental effect on its performance in service, d) Free from any projections that are sharp and rough on the edges and corners, and e) Re-usable. 2.1.2 The conductor shall be clamped by the use of a socket head grub screw. 2.1.3 The grub screw shall accommodate a size 4 Allen key. 2.2 Insulating sleeve 2.2.1 The insulating sleeve shall: a) Be of a high quality non-flammable, non-toxic rubber, b) Be red or black in colour, c) Have an easy but tight fit over the connector and cables used, and d) Be re-usable.

PAGE 4 OF 18 2.3 Size The following size conductors, as per table 1, shall apply to this connector and insulating sleeve: ITEM (Annex D) CONDUCTOR (mm 2 ) CORES KEY SIZE 1 16 2 4 1 16 4 4 3 25 4 4 Table 1: Basic conductor sizes End Connector Grub Screw Insulating Sleeve Figure 1: Typical arrangement of an end connector and insulating sleeve.

PAGE 5 OF 18 3 MARKING, PACKING AND DOCUMENTATION 3.1 Marking Each package shall bear the following information legibly and indelibly marked on a label that is securely attached to the package: a) Brand name or trade mark, b) Description of contents, c) All end connectors shall have the connector size number indelibly marked on the connector, d) All insulating sleeves shall have the connector size number indelibly marked on the sleeve, e) The quantity, and f) City Power s SAP number. 3.2 Packing The end connectors and insulating sleeves shall be so packed as to protect them from damage during normal transportation. 3.3 Documentation 3.3.1 Documentation shall be submitted in a technical catalogue format. 3.3.2 The technical catalogue shall specify the sizes, dimensions, reference numbers, and if applicable, the complete range of other products and accessories available. 4 QUALITY MANAGEMENT 4.1 The supplier (deemed to be an organization that undertakes any manufacturing or assembly operation) shall have a formally documented and implemented quality management system (QMS), that as a minimum meets with the requirements of the international code of practice for quality systems ISO 9002. City Power reserves the right to audit quality management systems for suitability and effectiveness, and to verify all goods for conformance prior to delivery. 4.2 Foreign, and third party manufacturers, shall, in addition, hold valid certification of their quality management system. Such certification shall be from a national quality systems certification body (Registrar), duly accredited by a QMS accreditation body, which is signatory to a mutual recognition agreement with South Africa.

PAGE 6 OF 18 5 TRAINING The supplier shall provide the following details with regard to certified staff training offered: a) the available training courses and their duration; b) the cost per delegate; c) the minimum number of delegates required; d) the certification of delegates; e) on-site training, and f) training course content.

PAGE 7 OF 18 Annex A - Bibliography None

PAGE 8 OF 18 Annex B - Revision information DATE. NO. NOTES Dec. 2003 0 First issue

PAGE 9 OF 18 Annex C - Item 1: END CONNECTOR NO. 2 SAP NO. 5510 Schedule A: Purchaser's specific requirements Schedule B: Guarantees and technical particulars of equipment offered Item Subclause of CP_TSSPEC_101 Description Schedule A Schedule B 1 Manufacturer xxxx 2 2.1.6 Grub screws supplied with each connector /No 3 3.1 Is the connector marked with the size? /No 4 3.1 Does the marking comply with /No 5 3.1 Brand name or trade mark marked on the connector? /No 6 3.2 Does the labelling comply with /No 7 3.3 Does the packing comply with /No 8 Installation instructions /No 9 3.3 Technical catalogue provided /No 10 5 Training provided /No Tender Number: Tenderer s Authorised Signatory: Name in block letters Signature Full name of company:

PAGE 10 OF 18

PAGE 11 OF 18 Item 1: END CONNECTOR NO. 2 SAP NO. 5510 Deviation schedule Any deviations offered to this specification shall be listed below with reasons for deviation. In addition, evidence shall be provided that the proposed deviation will at least be more costeffective than that specified by City Power. Item Subclause of CP_TSSPEC_101 Proposed deviation Tender Number: Tenderer s Authorised Signatory: Name in block letters Signature Full name of company:

PAGE 12 OF 18 Annex C - Item 2: END CONNECTOR SLEEVE NO. 2 SAP NO. 5511 Schedule A: Purchaser's specific requirements Schedule B: Guarantees and technical particulars of equipment offered Item Subclause of CP_TSSPEC_101 Description Schedule A Schedule B 1 Manufacturer xxxx 2 2.2.1 Material of insulating sleeve Rubber 3 2.2.2 Colour Red / Black xxx 4 3.1 Is the sleeve marked with the size? /No 5 3.1 Does the marking comply with /No 6 3.1 Brand name or trade mark marked on the sleeve? /No 7 3.2 Does the labelling comply with /No 8 3.3 Does the packing comply with /No 9 Installation instructions /No 10 3.3 Technical catalogue provided /No 11 5 Training provided /No Tender Number: Tenderer s Authorised Signatory: Name in block letters Signature Full name of company:

PAGE 13 OF 18

PAGE 14 OF 18 Item 2: END CONNECTOR SLEEVE NO. 2 SAP NO. 5511 Deviation schedule Any deviations offered to this specification shall be listed below with reasons for deviation. In addition, evidence shall be provided that the proposed deviation will at least be more costeffective than that specified by City Power. Item Subclause of CP_TSSPEC_101 Proposed deviation Tender Number: Tenderer s Authorised Signatory: Name in block letters Signature Full name of company:

PAGE 15 OF 18 Annex C - Item 3: END CONNECTOR NO. 3 SAP NO. 6233 Schedule A: Purchaser's specific requirements Schedule B: Guarantees and technical particulars of equipment offered Item Subclause of CP_TSSPEC_101 Description Schedule A Schedule B 1 Manufacturer xxxx 2 2.1.6 Grub screws supplied with each connector /No 3 3.1 Is the connector marked with the size? /No 4 3.1 Does the marking comply with /No 5 3.1 Brand name or trade mark marked on the connector? /No 6 3.2 Does the labelling comply with /No 7 3.3 Does the packing comply with /No 8 Installation instructions /No 9 3.3 Technical catalogue provided /No 10 5 Training provided /No Tender Number: Tenderer s Authorised Signatory: Name in block letters Signature Full name of company:

PAGE 16 OF 18

PAGE 17 OF 18 Item 3: END CONNECTOR NO. 3 SAP NO. 6233 Deviation schedule Any deviations offered to this specification shall be listed below with reasons for deviation. In addition, evidence shall be provided that the proposed deviation will at least be more costeffective than that specified by City Power. Item Subclause of CP_TSSPEC_101 Proposed deviation Tender Number: Tenderer s Authorised Signatory: Name in block letters Signature Full name of company:

PAGE 18 OF 18 Annex C - Item 4: END CONNECTOR SLEEVE NO. 3 SAP NO. 6234 Schedule A: Purchaser's specific requirements Schedule B: Guarantees and technical particulars of equipment offered Item Subclause of CP_TSSPEC_101 Description Schedule A Schedule B 1 Manufacturer xxxx 2 2.2.1 Material of insulating sleeve Rubber 3 2.2.2 Colour Red / Black xxxx 4 3.1 Is the sleeve marked with the size? /No 5 3.1 Does the marking comply with /No 6 3.1 Brand name or trade mark marked on the sleeve? /No 7 3.2 Does the labelling comply with /No 8 3.3 Does the packing comply with /No 9 Installation instructions /No 10 3.3 Technical catalogue provided /No 11 5 Training provided /No Tender Number: Tenderer s Authorised Signatory: Name in block letters Signature Full name of company:

PAGE 19 OF 18

PAGE 20 OF 18 Item 4: END CONNECTOR SLEEVE NO. 3 SAP NO. 6234 Deviation schedule Any deviations offered to this specification shall be listed below with reasons for deviation. In addition, evidence shall be provided that the proposed deviation will at least be more costeffective than that specified by City Power. Item Subclause of CP_TSSPEC_101 Proposed deviation Tender Number: Tenderer s Authorised Signatory: Name in block letters Signature Full name of company:

PAGE 21 OF 18 Annex D Stock Items Material Group : ELEC-ACCS Item SAP No. SAP Short Description SAP Long Description 1 5510 END CONNECTOR NO 2 END CONNECTOR. METAL WITH A SOCKET HEAD GRUB SCREW. TO BE USED WITH A NO. 4 ALLEN KEY. SUITABLE FOR CONNECTING COPPER CONDUCTORS UP TO 2 X 16 MM SQ PLUS 1 X 4 MM SQ. ITEM SPECIFICATION NO. CP_TSSPEC_101 2 5511 END CONNECTOR SLEEVE NO 2 END CONNECTOR. INSULATING SLEEVE. RED. SUITABLE FOR CONNECTING FOR INSULATING THE NO. 2 END CONNECTOR. ITEM SPECIFICATION NO. CP_TSSPEC_101 3 6233 END CONNECTOR NO 3 END CONNECTOR. METAL WITH A SOCKET HEAD GRUB SCREW. TO BE USED WITH A NO. 4 ALLEN KEY. SUITABLE FOR CONNECTING COPPER CONDUCTORS UP TO 2 X 35 MM SQ PLUS 1 X 16 MM SQ. ITEM SPECIFICATION NO. CP_TSSPEC_101 4 6234 END CONNECTOR SLEEVE NO 3 END CONNECTOR. INSULATING SLEEVE. RED. SUITABLE FOR CONNECTING FOR INSULATING THE NO. 3 END CONNECTOR. ITEM SPECIFICATION NO. CP_TSSPEC_101