Before we start. Copyright William C Cromer 2015

Similar documents
BOYLE S / CHARLES LAW APPARATUS - 1m long

OPERATING INSTRUCTIONS

tel: fax: web:

Exercise 2-3. Flow Rate and Velocity EXERCISE OBJECTIVE C C C

Construction Dewatering

Appendix B Harris County Standard Operating Procedure for Determining In Situ Hydraulic Performance of High Flow Rate Bioretention Media

DURRIDGE STAINLESS STEEL SOIL GAS PROBE

The water supply for a hydroelectric plant is a reservoir with a large surface area. An outlet pipe takes the water to a turbine.

29 Pressure, Temperature relationship of a gas

STANDARD OPERATING PROCEDURES. Andersen Instruments Federal Reference Method (FRM) Ambient Particulate (PM 10 /PM 2.

TO RECEIVE the most benefit from a

Florida Method of Test for MEASUREMENT OF WATER PERMEABILITY OF COMPACTED ASPHALT PAVING MIXTURES

Operating Instructions

INSTALLATION INSTRUCTIONS FOR GRT75-PF-RFS PET FOUNTAIN

OPERATING INSTRUCTIONS

Constructing a PVC Flute

In the liquid phase, molecules can flow freely from position. another. A liquid takes the shape of its container. 19.

In the liquid phase, molecules can flow freely from position to position by sliding over one another. A liquid takes the shape of its container.

METHOD 2E - DETERMINATION OF LANDFILL GAS PRODUCTION FLOW RATE. NOTE: This method does not include all of the

Tex-414-A, Air Content of Freshly Mixed Concrete by the Volumetric Method

In situ permeability measurement with the BAT Permeameter. Quick Manual Ou low test. Warranty details

In situ permeability measurement with the BAT Permeameter. Quick Manual Inflow test. Warranty details

Cover Page for Lab Report Group Portion. Head Losses in Pipes

Cover Page for Lab Report Group Portion. Pump Performance

DETERMINATION OF THE PERMEABILITY OF HOT MIX ASPHALT PAVEMENTS

An Improved Understanding of LNAPL Behavior in the Subsurface LNAPL - Part 1

Rates of Change GCSE MATHEMATICS. These questions have been taken or modified from previous AQA GCSE Mathematics Papers.

Exploring the Properties of Gases

STAD-D. Balancing valves Balancing valve for domestic water systems, DN Balancing valves

Evaluation of the function of Vertical drains.

EFLOW GUIDE. IRRIGATE UP TO 200m 2 SUITS DOMESTIC ONSITE APPLICATIONS

Standard Test Method for Infiltration Rate of Soils in Field Using Double-Ring Infiltrometer 1

SOIL GAS PROBE. In-Ground Radon Detection Accessory for the RAD7. DURRIDGE Hardened Steel Soil Gas Probe AMS Stainless Steel Soil Gas Probe

VACUUM TESTING PRECAST CONCRETE MANHOLES

Industrial Pneumatics

A Review of the Bed Roughness Variable in MIKE 21 FLOW MODEL FM, Hydrodynamic (HD) and Sediment Transport (ST) modules

1. The principle of fluid pressure that is used in hydraulic brakes or lifts is that:

Heat Engine. Reading: Appropriate sections for first, second law of thermodynamics, and PV diagrams.

Operating Instructions

Alan Davis Field Trip Activities

Module 2, Add on Lesson Depth Sensor. Teacher. 90 minutes

OPERATING INSTRUCTIONS

Standard Test Procedures Manual

CHAPTER 5: VACUUM TEST WITH VERTICAL DRAINS

ANSWERS TO QUESTIONS IN THE NOTES AUTUMN 2018

1. All fluids are: A. gases B. liquids C. gases or liquids D. non-metallic E. transparent ans: C

Blue Points 1 ¼ WELL POINT INSTALLATION INSTRUCTIONS

Department of Civil & Geological Engineering GEOE Engineering Geology

Orifice & Free Jet Flow. Instruction Manual F1-17 ISSUE 8

Energy Drilling Prospects

Cover Page for Lab Report Group Portion. Drag on Spheres

Single-Interval Gas Permeability Testing

(AS AT 31 st MARCH, 2002)

Pore-Air Entrapment during Infiltration

Ideal gas law. Introduction

#LZ400 LEAKALYZER. Water Loss Sensor INSTRUCTION MANUAL Country Dr. #190 St. Paul, MN

Vapor Sorption Analyzer

_ pressure transducers. User Manual

LOW PRESSURE EFFUSION OF GASES revised by Igor Bolotin 03/05/12

Experiment 11: The Ideal Gas Law

Fluid Machinery Introduction to the laboratory measurements

CONE PENETRATION TESTS

Pesticide Applicator Safety for Structural Applicators Calculations

BioAerosol Nebulizing Generator. Operation and Maintenance User Manual

OHD L-44 METHOD OF TEST FOR MEASUREMENT OF WATER PERMEABILITY OF COMPACTED PAVING MIXTURES

Applications of Bernoulli s principle. Principle states that areas with faster moving fluids will experience less pressure

TEST FOR STABILOMETER VALUE OF BITUMINOUS MIXTURES

Infiltration and Air Pressure Build-up

Soil water retention determination using the Wetlab facility at CSIRO, Davies Laboratory

Exploring the Properties of Gases. Evaluation copy. 10 cm in diameter and 25 cm high)

Relative Humidity Calibration Kit

Using the Akta Prime plus October 22, 2012

Science 8 Chapter 9 Section 1

1. Introduction Why use the Flow-Through Cell? Component Identification... 1

Exp. 5 Ideal gas law. Introduction

Tripod Setup Guide (M-TPx)

EUROFLO CULVERT PIPE. Fittings / Pipes

Fun Physics Workshop

OHD L-44 METHOD OF TEST FOR MEASUREMENT OF WATER PERMEABILITY OF COMPACTED PAVING MIXTURES

The activated sludge process

IMPORTANT PLEASE READ BEFORE COMMENCING INSTALLATION

RST INSTRUMENTS LTD.

PHYS 101 Previous Exam Problems

Quiz name: Chapter 13 Test Review - Fluids

γ water = 62.4 lb/ft 3 = 9800 N/m 3

Third measurement MEASUREMENT OF PRESSURE

. In an elevator accelerating upward (A) both the elevator accelerating upward (B) the first is equations are valid

AP Lab 11.3 Archimedes Principle

3. A fluid is forced through a pipe of changing cross section as shown. In which section would the pressure of the fluid be a minimum?

Standard Test Method for Field Measurement of Infiltration Rate Using a Double-Ring Infiltrometer with a Sealed-Inner Ring 1

Cell Disruption System

Hours / 100 Marks Seat No.

Static Fluids. **All simulations and videos required for this package can be found on my website, here:

Hydrostatics Physics Lab XI

OPERATING INSTRUCTIONS

L 100. Bubble-Tube Level System. Installation, Operation and Maintenance Instructions

Depth sensor. Product reference : REV 1. USER GUIDE and INSTALLATION GUIDE. nke Sailing competition

FINALIZATION OF THE HAND DUG WELL. Version : April 2009 Published by : Foundation Connect International Autors : Henk Holtslag & John de Wolf

LAB 13: FLUIDS OBJECTIVES

m v = 1.04 x 10-4 m 2 /kn, C v = 1.29 x 10-2 cm 2 /min

Transcription:

Before we start Welcome to this preview of the Cromer Constant Head Permeameter. In Microsoft PowerPoint, the preview is best viewed as a full-screen Slide Show presentation. If your current view is smaller, we strongly recommend you go to Slide Show on the menu bar above, and select View Show from the drop-down menu. To move from one slide to the next within the Slide Show, left-click your mouse (anywhere on your screen will do) or use the up and down arrow keys. To end the Slide Show at any stage, right-click and select End Show from the drop-down menu. To revisit a slide from within the Slide Show, use the up arrow, or rightclick and select Go and By Title from the drop-down menu. If you need to, choose View Show now. Left click to go to the next slide. Right click to navigate or end the slide show. This message will not be repeated.

This preview is free, and may be copied, printed or e-mailed for further distribution, but only in full. Users are reminded that its contents, including all text and diagrams, are copyright, and should not be amended in any way. For more information, contact: Bill Cromer Email Website 61+408 122 127 billcromer@bigpond.com www.williamccromer.com

The CROMER CONSTANT HEAD PERMEAMETER - a Preview Bill Cromer B.Sc. Hons (Geology) June 2015

What does the permeameter do? The Cromer Constant Head Permeameter is designed to measure the hydraulic conductivity (commonly called 'permeability') of nearsurface, unsaturated soils, sediments, fractured rocks, fill, or any other suitable material, under constant head field conditions. The test is usually done in a shallow, circular, augered hole. The practical range of permeabilities able to be measured with the instrument is between about 0.005 and 10 metres per day (m/day).

Why was the permeameter conceived? The permeameter was conceived primarily to aid in the assessment of soils and sites for in-ground wastewater disposal (for example, using the Trench 3.0 software package), but it has many other uses. The range of permeabilities able to be measured (from about 0.005 m/day to about 10 m/day) spans the range of permeabilities of most soils, including those most suitable for wastewater disposal.

What does constant head mean? Constant head means that a constant depth of water is maintained in the test hole during the permeability test. The test measures the rate of flow of water into the hole from a graduated reservoir. This contrasts with the Falling head or Percolation test method, which measures the rate of fall of the water level in a test hole. Falling head tests are generally discouraged.

Test only unsaturated materials Although the permeameter can be set up to measure permeabilities below a water table, the equations provided in the Manual and in this slide show are applicable only to unsaturated materials above a water table. Unless you are able to apply the correct equations for saturated conditions, you should use the instrument to test only unsaturated materials.

Units of permeability Permeability is a measure of the volume of fluid moving through a cross-sectional area in a given time. Units can therefore be, for example, cubic metres per day per square metre, cubic centimetres per second per square centimetre, etc. These two examples reduce to metres per day (m/day), and centimetres per second (cm/sec) respectively. Other commonly used units are cm/min, cm/sec, m/sec, and in the imperial system, ft/day. In the Instruction Manual, permeability is expressed in m/day.

Materials and their permeabilities Typical ranges of permeability for naturally-occurring materials are: m/day Clay soils at the surface 0.01 to 0.2 Clays at deeper levels 10-8 to 10-2 Clay, sand and silt mixtures 0.01 to 1 Sand (fine grained) 1 to 5 Sand (medium grained) 5 to 20 Sand (coarse grained) 20 to 100 Gravel 100 to 1000

Equipment supplied with the permeameter The basic package contains the following equipment: - one clear polycarbonate, 4.5 litre, graduated water reservoir, fitted with an (optional) valve (tap) at the bottom and a rubber bung at the top, - four 20mm diameter delivery tubes of various lengths, - two 50mm diameter PVC slotted screens, and assorted fittings, - reels of thread tape for airtight seals on the delivery tubes, - a hard-copy Instruction Manual, various files on a storage device, - a basal plate to support the instrument over the test hole, and - a robust carry case.

Equipment supplied with the permeameter Rubber bung Graduated 4.5-litre, polycarbonate reservoir Support base Thread tape Optional valve (tap) Threaded delivery tube Joiners Delivery tubes Threaded screened casing to support collapsing holes

Equipment supplied with the permeameter Instruction manual and carry case

How the permeameter works Like other constant head permeameters, the Cromer permeameter is essentially a graduated water reservoir and a delivery tube, which together operate on a very simple principle to maintain a constant depth of water in the test hole. For permeability testing, the reservoir is fitted with a delivery tube, and the assembly is lowered vertically into a test hole (containing previously-added water) until the lower, open end of the tube is just immersed in the water.as follows.

How the permeameter works Reservoir containing water. Rubber bung firmly in place at top. With (optional valve open and) tip of tube immersed, no water can leave the instrument. Ground surface Partial vacuum created. (More accurately, atmospheric pressure acting on the surface of the water in the test hole supports the column of water in the tube and reservoir.) Valve (optional) open Tip of tube immersed Auger hole with added water

How the permeameter works Water infiltrates into the soil, and the water level in the test hole drops. Air enters the tip of the open delivery tube, and rises as bubbles in the reservoir Ground surface Tip of tube now exposed to air Infiltration of water into soil, at a rate determined by the permeability of the soil. Air Valve (optional) open

How the permeameter works Air bubbles rising in reservoir displace an equal volume of water out the delivery tube into the test hole. Water level in reservoir therefore falls, and water level in test hole rises until the tip of the delivery tube is once again immersed. Bubbles then cease, and all activity (except infiltration into the soil) temporarily stops before starting again. The net effect is a constant water level in the test hole, at the tip of the delivery tube. The sole purpose of the reservoir is to deliver water at the required rate so as to keep the water level in the test hole at the tip of the delivery tube. Bubbles stop Valve (optional) open Tip of tube once again immersed Auger hole with added water

Doing a permeability test Step 1. Select a site. Auger or dig one or more circular holes to establish the soil profile, and the interval you want to test. You may also need to log (describe the materials in) the holes, locate the holes with GPS coordinates and/or show them on a site sketch. Auger hole

Doing a permeability test Step 2. Select a hole. The top of the interval you test is determined by the combined length of the (optional) valve and delivery tube on the permeameter. The bottom is determined by the depth of the hole. Ideally, the test interval (i.e. depth of water) should be at least 3 times the hole diameter. Optional valve Delivery tube (choose a length to suit your test) If the hole is in clayey or similar materials which smear during augering, scour or scrape its sides and bottom to restore permeability. Clean out. Top Test interval Bottom

Doing a permeability test Step 3. Screw the desired length of delivery tube to the base of the permeameter. Add test water to the instrument through the bung hole at top. (To do this more easily, stand the permeameter upright with your finger blocking the open end of the delivery tube, or close the optional valve.) Make airtight by pushing the rubber bung firmly into place. The bung will fit easier if you wet it first. Check instrument for leaks. Lay it aside. Optional valve closed Reservoir does not need to be full

Doing a permeability test Step 4. Insert the slotted 50mm PVC screen into the hole (if required). Add water to the hole, to near the top of your test interval. Add the circular base to hold the instrument upright. Until you insert the permeameter, you may need to keep topping the water level in the hole up as the Place support Test water water infiltrates the soil. base over hole Optional valve shut Top Test interval Overfill for sandy soils Underfill for clayey soils

Doing a permeability test Step 5. Hold the permeameter vertically over the open hole, with your finger over the open end of the delivery tube, or, if you are using the valve supplied, open it now, and lower the instrument into the hole until the base of the reservoir rests in its support base on the ground. Instrument placed inside its support base Remove finger or open optional valve

Doing a permeability test Step 6. In high permeability soils. If you have slightly overfilled the hole with test water (because the soils are sandy or of high permeability), record the volume in the reservoir now. The test starts when the water level in the hole falls below the level of the tube, and bubbles start rising in the reservoir. Record water level before bubbles rise and test starts Overfill for sandy soils

Doing a permeability test Step 6 (continued). In low permeability soils. If you have slightly underfilled the hole with test water (because the soils are clayey or of low permeability), the test starts only when the water level in the hole rises to the level of the tube, and bubbles temporarily stop rising in the reservoir. Record the water level in the reservoir when bubbles temporarily stop. Record water level after initial bubbles stop and test starts Underfill for clayey soils

Doing a permeability test Step 7. Record the water level in the reservoir at various times. Record the time interval between readings. For example, in high permeability soils, measure the level every minute or so, as required. In moderate permeability soils, measure the water level every (say) 5 to 20 minutes. In low permeability soils, measure the water level at longer intervals. Record water levels, and time intervals between readings Water level remains constant

Doing a permeability test Step 8. As the test continues, track the rate of flow (L/min) from the instrument for different pairs of readings. For example, Water level at time t = 4.95 L Water level 2 mins. Later = 4.55 L Infiltration (flow) in 2 mins = 0.4 L Flow in 1 min = 0.2 L End the test when 2 or more successive flow rates do not differ by more than about 10%. Record water levels, and time intervals between readings Water level remains constant

Doing a permeability test Step 9. You may use less than a litre of water testing low permeability materials, less than a reservoir full (about 4.5 L) in moderate permeability materials, and perhaps 10-15 L doing a test in high permeability materials. If you have to refill the instrument during a test, treat the refill as a separate test: ie pull out, turn (optional) valve off, pull out bung, refill instrument, replace bung, test for leaks, lay aside, top-up test hole (overfill), open valve, re-insert instrument, start readings. Continue readings to steady flow rate.

Doing a permeability test Step 10. Backfill the auger hole(s) tightly. Open holes are dangerous to (the legs of) humans and animals. Clean up the site.

Minimum recording of test results You should record field results in a systematic manner. The minimum information you require to calculate a permeability from a circular test hole is: test hole diameter depth of water in test hole (steady) flow rate from instrument in L/min (which must be converted to cubic metres per day by multiplying by 1.44).

Defensible recording of field results To be defensible, you should record more than the minimum information required. This field sheet is a suggested example. It summarises two tests. It also allows you to graph the flow rate with time, to better see when steady-flow conditions are approached. Copy it from the hard or digital copy of the Instruction Manual supplied with the permeameter. (Company name) (Company address, etc.) Permeability Field Test Project Test site description Constant head permeameter Test hole geometry Hole depth (m) Hole diameter (mm) Depth to water (m) Depth int. tested (m) TEST 1 Time (hr:m) Tested soil type Time elapsed (mins) Instrument brand name Location ID Reservoir volume (L) Sheet of TEST 1 TEST 2 TEST 1 TEST 2 Source of test water Volume reading (L) Volume infiltrated (L) Infiltration rate (L/min) Est. salinity of test water (mg/l) Est. SAR of test water Depth (m) below hole to imperm. layer TEST 2 Time (hr:m) Tested soil type Time elapsed (mins) Volume reading (L) Tested by Volume infiltrate d (L) Infiltration rate (L/min) For more details of the test, you should add test hole depth, description of the materials in the hole, GPS grid coordinates of the hole, and site photographs TEST 1 Graph of field results Time (mins) since first reading Volume reading (L) TEST 2 Volume reading (L) Graph of field results Time (mins) since first reading

Calculating permeability To calculate permeability from constant head tests, the Instruction Manual uses two equations. The first is from Australian/New Zealand Standard 1547-2012 On-site domestic wastewater management (page 118). The second is from Australian Standard 1547-1994 Disposal systems for effluent from domestic premises, and Talsma and Hallam (1980). These and other references are listed at the end of this slide show. These equations are approximations because they include simplifying assumptions about soil conditions and infiltration processes. Other equations are available, and these also provide approximate results.

Calculating permeability This diagram shows the symbols used for the equations. Fall in water level Reading at earlier time Reading V 1 at time t 1 K = permeability of the soil Q = rate of flow of water from the instrument (steady infiltration rate), equal to (V 1 V 2 )/(t 2 - t 1 ) opposite. H = the depth of water (wetting) in the test hole r = the radius of the test hole (= half diameter, d/2) S = the depth to the impermeable layer Surface Reading V 2 at time t 2 Q = (V 1 V 2 )/(t 2 - t 1 ) If V is in Litres, and t is in minutes, Q is in Litres/minute. To convert Litres/minute to cubic centimetres/minute, multiply by 1000. To convert Litres/minute to cubic metres/day, multiply by 1.44 (i.e. 1 Litre/minute = 1.44 cubic metres/day). sinh -1 = the inverse hyperbolic sine function π= Pi (i.e. 3.1416) H>=5d H Tested soil interval (permeability K) d r S Impermeable layer (permeability<=0.1k)

Calculating permeability Equation 1 Equation 1 is used in situations where the distance from the bottom of the test hole to an impermeable layer is more than twice the depth of water in the hole (i.e. where S>2H in the previous slide): K = 4.4Q.{0.5sinh -1 (H/2r)-[(r/H) 2 +0.25] 0.5 +r/h}/2π H 2 (Equation 1) If Q = L/day, and H and r are in metres, K is in metres/day. If Q = cm 3 /min,and H and r are in cm, K is in cm/minute. The impermeable layer should have a permeability less than one-tenth that of the soil being tested. You should establish whether such a layer exists at your test site before deciding whether to use Equation 1 or Equation 2.

Calculating permeability Equation 2 Equation 2 is used in situations where the distance from the bottom of the test hole to an impermeable layer is equal to or less than twice the depth of water in the hole (i.e. where S<=2H): K = 3Q.ln(H/r)/π H(3H + 2S) (Equation 2) If Q = L/day, and H, r and S are in metres, K is in metres/day. If Q = cm 3 /min,and H, r and S are in cm, K is in cm/minute. This equation should not be used if a more permeable layer exists beneath your surface layer.

Calculating permeability nomogram If you have used a circular, 120 mm diameter hole for your test, this nomogram can be used in the field or office to estimate permeability calculated from Equation 1 (but not Equation 2). The nomogram is also in the Instruction Manual.

Calculating permeability precision Soil permeability can change substantially over very small distances, both horizontally and vertically. The Cromer Constant Head Field Permeameter has in-built imprecision (for example, you cannot read water levels more accurately than to about the nearest 0.05 L), and the equations you are using are approximations. Therefore, don t report your calculated permeability to more significant figures than your data allow. For example, a reported field permeability of 0.0125 m/day is unjustified. Round it off to 0.013 m/day, or better still, 0.01 m/day. Similarly, 3.79 m/day should be rounded off to 4 m/day. Generally, extra accuracy and precision are not needed.

Further reading Australian Standard 1547-1994. Disposal systems for effluent from domestic premises. Standards Association of Australia. Australian/New Zealand Standard 1547-2012. On-site domestic wastewater management. Standards Association of Australia. Reynolds, W. D. and Elrick, D. E. (1983). A Reexamination of the Constant Head Well Permeameter Method for Measuring Saturated Hydraulic Conductivity above the Water Table. Soil Science, 136 (4) pp 250-268. Reynolds, W. D., Elrick, D. E. and Clothier, B. E. (1985). The Constant Head Well Permeameter: Effect of Unsaturated Flow. Soil Science, 139 (2) pp 172-180. Talsma, T. and Hallam, P. M (1980). Hydraulic Conductivity Measurement of Forest Catchments. Australian Journal of Soil Research, 30, pp 139-148. Zangar, C. N. (1957). Theory and Problems of Water Percolation. Engineering Monograph No. 8, Bureau of Reclamation, US Dept. of the Interior (Denver, Colorado). 75 pp.

This is the last slide. Right-click and select End Show from the drop-down menu.