Pneumatic Outflow Control

Similar documents
BUBBLER CONTROL SYSTEM

Float operated valve TYPE (SWDS)

BUBBLER CONTROL SYSTEM

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

Model 601CV. Mass Flow Controller. Product Features:

Mud Diver. Suspended solids level measurement and tank profile station for Clarifier, Thickener, CCD and Washer Control Optimisation

CSO/STORMWATER MANAGEMENT. HYDROVEX HHV-E Vortex Driven Regulator

WF STEUERUNGSTECHNIK GMBH. INFORMATION and TECNICAL DESCRIPTION

SILO SAFTEY EQUIPMENT. Silo Safety System KCS

FUNDAMENTAL PRINCIPLES OF SELF-OPERATED PRESSURE REDUCING REGULATORS. John R. Anderson Emerson Process Management Fluid Controls Institute

The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions

SILO SAFTEY EQUIPMENT. Silo Safety System KCS

200A Series ELECTRONIC LEVEL TRANSMITTER

CCT-7320/ROC-2313 Reverse Osmosis Controller

Automatic Control Unit. Cervomatic EDP.2. Type Series Booklet

LEA_EN_PZL Dynamometric Scale. Instruments and Systems for Geotechnical and Structural Monitoring

TH-1800-T TRX-700-CNG Converter

How to specify a product. Process Sensors and Mechanical Instruments

Pressure Independent Control Valves

Pneumatic Grippers Swivel Modules

Project Title: Pneumatic Exercise Machine

Installation and Operating Instructions Bypass Flow Meter DST

Integral type Differential pressure flowmeter VNT Series

Flamco Flamco-Fill STA Flamco-Fill STM

The benefits of the extended diagnostics feature. Compact, well-proven, and flexible

PWG-S. Application example. Pneumatic 2-Finger Angular Gripper Universal Gripper. Sizes. Gripping moment 5.98 Nm Nm. Weight 0.21 kg 1.

CSO/STORMWATER MANAGEMENT. HYDROVEX FluidMoon Self-Adjusting Knife-Gate Regulator

Model PIV UL/FM Post Indicator Valve. Maintenance and Operation Manual UL/FM Post Indicator Valve Configuration AWWA C515

High-performance submersible pressure transmitter For level measurement Model LH-20

Pneumatic high-pressure controller Model CPC7000

Pneumatic Gripping Modules. Pneumatic 2-Finger Radial Grippers

High-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20

Float Operated Level Controllers

Service Test Unit for ROSS Proportional Valves RESK

Features. Main Voltage: Vdc. Input Control Signal: 0-5 Vdc or 4-20 madc (Sourcing) Monitor Output Voltage: 0-5 Vdc or 4-20 madc (Sourcing)

TR Electronic Pressure Regulator. User s Manual

SonoMeter 30 Energy Meters

Product Information. Tolerance compensation unit TCU-Z

Tightness controls TC 1 3 and TC 4

Mass Flow Controller (MFC) for Gases

CONTROL and INSTRUMENTATION

DPZ-plus. Application example. Pneumatic 3-Finger Centric Grippers Sealed Grippers. Gripping force 520 N N. Sizes

SPG. Application example. Pneumatic 2-Finger Parallel Gripper Heavy-load Gripper. Weight 35 kg. Stroke per finger 100 mm.

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

REASONS FOR THE DEVELOPMENT

LT GasAnalyzer. LT GasAnalyzer Page 1 of 6

Visualize Nitrogen Gas Consumption

PZN-plus. Application example. Pneumatic 3-Finger Centric Gripper Universal Gripper. Sizes Gripping force 580 N..

GWB Pneumatic 2-Finger Radial Gripper Universal Gripper Sizes Weight Gripping moment Opening angle per finger Workpiece weight

NIV EAU MATIC ST User Manual Made in Canada

Pettinaroli Pressure Independent Control Valves. EvoPICV

Pneumatic high-pressure controller Model CPC7000

2600T Series Pressure Transmitters Plugged Impulse Line Detection Diagnostic. Pressure Measurement Engineered solutions for all applications

Mass Flow Controller (MFC) for Gases

Ultima. X Series Gas Monitor

Lecture 10 : Sewer Appurtenances

Coriolis Mass Flow Meter

Design Features. General Description

HumiSys HF High Flow RH Generator

Test pumps. Pressure sources. Good reasons for proper and reliable calibration

Quick Installation Guide Doc nr.: C Date:

SINGLE VALVE WITH LOW-FLOW BYPASS

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

GAS FUEL VALVE FORM AGV5 OM 8-03

LT GasAnalyzer beyond standards

WW-730. Pressure Sustaining/Relief Control Valve

9A5N Solid State CW Paddle

X-Flow Mass Flow Controller 授权代理 : 北京品超思瑞科技学院公司

VACUVENT Valve functions - benefits - flowpath - VG series - Sewage

PGN. Application example. Pneumatic 2-Finger Parallel Grippers Universal Grippers. Gripping force 100 N N. Sizes

RS 2-75 D 109 D RSF 87 D 127 D with direct drive

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

Experiment Instructions. Circulating Pumps Training Panel

High-performance submersible pressure transmitter For level measurement Model LH-20

DF-550E PROCESS ANALYSERS APPLICATIONS FEATURES

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

COMPRESSOR PACK SUCTION CONTROLLER TYPE: LP41x

REF Description Picture Technical data Page

CONDUCTIVITY POINT/S LEVEL SWITCH JAYCEEAQUA 4000 SERIES

ENS-200 Energy saving trainer

Application of CHE100 in Frequency Conversion Alteration of Air Compressor System

SCOPE OF THIS GUIDE STARTING-UP. 1 Check mini CORI-FLOW functional properties

Electronic gas volume corrector model DGVC-04

Mass Flow Meter (MFM) for Gases

Autocalibration Systems For In Situ Oxygen Analyzers

Technical Data Sheet MF010-O-LC

PRODUCT DATA SHEET (ver.02/ ) One flap non return valves ( mm) Double flaps non return valves ( mm)

LX Compass module 3 Electronic compass device User manual

Pressure independent control valve (PICV) FLOWMATIC

DAV - WP DAV - WP. Wastewater Air Valves. Product Catalogue. (Wastewater Air Valves) DAV - WP

ACV-10 Automatic Control Valve

MANUAL KPS Pressure Control Valve

Brooks TMF-Zone 1 Models 5816-Ex/5864-Ex

Technical Information Conducal CLY421

- From 2005 year model, replacing with RM250 with 2-stroke engine, RM-Z450 with 4-stroke engine was introduced in the market. - From 2008 year model,

PFH. Application example. Pneumatic 2-Finger Parallel Gripper Long-stroke Gripper. Weight 2.65 kg 12.6 kg. Gripping force 630 N 2950 N

Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter

EXPERIMENT 1 AIR PRESSURE CONTROL SYSTEM

SCAM T.P.E. WATER TREATMENT SYSTEM SWT- AP AUTOMATIC PURGE

Transcription:

Technical Bulletin Pneumatic Outflow Control Pneumatically powered controls for the precise limitation of the volumes of waste water and rain water

Contents Applications... 3 Success features... 4 Technical design... 5 Wet installed pneumatic outflow control... 6 Dry installed pneumatic outflow control... 7 Function... 8 Fully-filled control... 8 Quantity control... 8 Emergency operation during power failure and equipment fault... 8 Flushing surge to prevent deposits... 9 Part-filled mode... 9 Self-control... 9 Typical assembly process... 10 Advantages.... 11 Reliability... 11 Control accuracy... 11 Ease of maintenance... 11 Cost cutting... 11 Technical specifications... 12 Theoretical construction lengths... 12 Wet installed version... 12 Dry installed version... 13 Communication interfaces... 13 Contact data... 14 Pneumatische Abflussregelung August 2016 STEBATEC AG 2

Applications Two different types if equipment are used for the pneumatic outflow control. One for fully filled and one for partly filled outflows. Both are mainly used: at the outflow end of storm-water basins and storm-water overflows for limiting the outflow to the sewage treatment plant. at the outflow end of road runoff treatment plants (SABA) for limiting the flow rate. Self-cleaning flow measurement with 40 % less pondage when compared with conventional flow meters. Flow direction Pneumatische Abflussregelung August 2016 STEBATEC AG 3

Success features Pneumatic outflow controls are important components of an integral control system of the sewerage and a must for future intelligent storm-water basin controls. The throttling level parameters can be set / are variable across the entire outflow range The system can be remote-controlled and is compatible with all conventional process control systems in the market Supports water-holding management Measures the flow with a maximum deviation of 1% of the measuring value, controls with high precision, with shortest integral-action time and without limitation of the operating time Combined flow metering and control system, including stilling section, on the smallest possible footprint area Detects pollutions and eliminates them systematically (flushing surge, debris elimination) Continues operating on an emergency program during a power failure Admits part-filled operation and prevents deposits Is easy to maintain and can be removed/opened without tools Works with a standardized, fully mature control program Can be installed in wet or dry environment Pneumatische Abflussregelung August 2016 STEBATEC AG 4

Technical design Control with fully filled flow measurement Example of a suspended type adaption Cable with protective hose Rope suspension point Spring Lifting cushion Hatch open Hatch Runoff collar splash guard Flanged bolts Hatch closed Control with part-filled flow measurement Electronics box Gaspressure spring Sensor box Hatch Double bellows Hatch open Hatch closed Pneumatische Abflussregelung August 2016 STEBATEC AG 5

Wet installed pneumatic outflow control The wet installed pneumatic outflow control in original design. Exemplary formation in the inflow of the outflow controller. The formation was made already transformed into a rectangle, a few meters before the throttle section. Shortened construction, where the slow down section was installed in the upstream wall and into the room before. Pneumatische Abflussregelung August 2016 STEBATEC AG 6

Dry installed pneumatic outflow control Pneumatische Abflussregelung August 2016 STEBATEC AG 7

Function The pneumatically controlled hatch ensures that the MID (if installed) is fully filled and restricts the flow to a pre-settable maximum value. A pneumatic pressure cushion controls the hatch; when the cushion inflates, a lever axis closes the hatch. In deflated state, the hatch remains open without backpressure. Fully-filled control In dry weather and when the flow is less than the throttled flow, the system switches to automatic fully-filled control (provided this function is enabled). Controlled by the signal of the integrated pressure sensor, the hatch opens wide enough that the fully-filled state of the measuring sensor is maintained. This ensures highest measuring accuracy by the measuring sensor (magnetic-inductive flow measurement for fully-filled state). Fully-filled level Quantity control When the pre-set flow rate is exceeded, the plant switches to quantity control in which the flow is controlled by the signal of the flow measurement and limits the outflow quantity accordingly. Emergency operation during power failure and equipment fault The pneumatic outflow control features several possible reactions to an emergency; these will be defined together with the responsible sales engineer. Pneumatische Abflussregelung August 2016 STEBATEC AG 8

Emergency throttle In standard versions of the plants, the hatch is normally open when no power is supplied. This may not be suitable for some applications because the pre-set flow level may not be maintained when power fails. In the event of power failure, the emergency throttle shortens the pressure cushion at the controller with the pressure reservoir at the compressor by a pressure reducer. The setting of the pressure reducer defines the cushion pressure in emergencies. The setting depends on the situation we will be glad to advise you. Flushing surge to prevent deposits To prevent deposits which may occur during basic full-filling or also to improve the dynamic behaviour of the sewer system, the plant has a self-cleaning function (flushing surge). The surge is produced by closing the hatch in controlled intervals and then opening it to produce a controlled surge flushing. Part-filled mode In systems with part-filled flow measurement, the part-filled mode is enabled permanently. The system switches to quantity control automatically when the maximum amount is obtained. In the version with magnetic-inductive (MID) flow measurement the control hatch maintains the system in fully filled state. This causes basic filling in the upstream line. In part-filled mode, the control hatch remains open in dry weather and only changes to fully-filled or quantity control mode when the water level rises. Without basic filling, the risk of deposits everywhere in the sewerage decreases. If the MID is to be used again later, a simple mouse-click can disable the part-filled mode. Self-control The pneumatic outflow control operates on three reference signals, viz. flow (flow measurement), water level, and pneumatic backpressure in the pressure cushion. The relations among these three reference signals must always be within defined limits; otherwise the system changes its state: If the water level in proportion to the flow and the backpressure in the cushion is too high, deposits in the control hatch are assumed = the hatch opens briefly. If the pressure in the cushion increases whereas flow and water level remain constant, the hatch may be jammed by debris = the hatch opens briefly. Pneumatische Abflussregelung August 2016 STEBATEC AG 9

Typical assembly process The assembly process of the part-filled pneumatic outflow control described below by way of example applies analogously also to the fully-filled pneumatic outflow control. Lower the pneumatic outflow control unit down the manhole into the shaft on ropes. Align the unit horizontally in the previously installed adaption for suspended installation and lower the unit until the top edge of the wedge plate is flush with the adaption. During initial installation, the feet supporting the unit have been adapted to the canal in such a way that the unit is horizontal when positioned finally. Pneumatische Abflussregelung August 2016 STEBATEC AG 10

Advantages Reliability The uncomplicated system design and the use of suitable materials ensure reliable operation of the system for many years. Control accuracy The control hatch is located immediately downstream the flow measurement so it reacts quickly to changes and can maintain the programmed control value with only minutest deviations. For comparisons with knife gate valves flow controls the fixed rule is 1 to 10: Whereas a knife gate valve can 100 individual positions in steps, the pneumatic outflow control with its step less pressure control, by comparison, covers at least 1000 individual positions which is the basis for the high control accuracy. Ease of maintenance The flow inside the unit is a laminar flow so that solids and debris are eliminated systematically. As a consequence of this, the maintenance intervals are longer. The STEBATEC adaption for suspended installation of the unit makes installation and removal a lot easier. The unit, which has no bolts or screws, is positioned exactly so that no alignment is necessary after installation. Cost cutting In many applications, the pneumatic outflow control does not require or when compared with other systems requires fewer modifications of the existing building structure, which cuts the overall cost. Pneumatische Abflussregelung August 2016 STEBATEC AG 11

Technical specifications Measuring range: 0.2 5000 l/s (depends on the system nominal size) Control range: 0.2 l/s and more Nominal sizes: 100 mm 1500 mm Materials: Polypropylene; metal V4A or as required Seals/gaskets: EPDM Temperature: 0 45 C ph range: 6 9 Protection class: IP 68 Compressed-air supply: Compressor with automatic water drainage Voltage supply: 230 V / 50 Hz / 10 A Theoretical construction lengths Wet installed version Pneumatische Abflussregelung August 2016 STEBATEC AG 12

Dry installed version interfaces Communication Standard with GPRS modem, fixnet internet link and VPN technology Signal outputs: 4 20 ma: momentary flow rate and set control value digital (active/passive): quantity meter and 2x fault Signal inputs: 4 20 ma: setpoint control value digital (floating): OPEN (remote); CLOSE (remote); AUTOMATIC; MANUALL START CLEANING; Communication: RS485 (Modbus RTU/ASCII), RS232, ethernet (Modbus TCP) Linkup via GPS possible. VPN links for remote maintenance by STEBATEC (internet link via GPRS required) Terminal connections diagram on request Pneumatische Abflussregelung August 2016 STEBATEC AG 13

Contact data STEBATEC AG Mattenstrasse 6a CH-2555 Brügg Tel. +41 (0)32 373 15 71 Fax +41 (0)32 373 15 63 info@stebatec.ch www.stebatec.ch Pneumatische Abflussregelung August 2016 STEBATEC AG 14