Seated valve for steam (PN 25)

Similar documents
Seated valve for steam (PN 25) VFS 2 2-way valve, flange

3-way control valves VK 3

Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange

2 - way valve for steam, pressure relieved (PN 25) VGS - external thread

Seated valves (PN 6) VL 2 2-way valve, flange VL 3 3-way valve, flange

Seated valves VRB 3, VRG 3

Pressure balanced valves (PN 25)

2 - way valve (NO) for steam, pressure relieved (PN 25) VGS - external thread

Pressure reduction controller (PN 16, 25, 40)

VZL valve - 2/3/4-way

Pressure balanced valves (PN 25) VM 2 2-way valve, external thread VB 2 2-way valve, flange

The valves are used in combination with AMV(E) 130/140, AMV(E) 130H/140H and AMV(E) 13 SU actuators. DN k VS

The valves are used in combination with AMV(E) 130/140, AMV(E) 130H/140H and AMV(E) 13 SU actuators. DN k VS

Rotary valves HRB 3, HRB 4

Differential pressure controller (PN 25) AVP - return and flow mounting, adjustable setting

Differential pressure controller with flow limitation (PN 16, 25, 40) AFPB / VFQ 2(1) AFPB-F / VFQ 2(1)

2-Port Seat Valves with Flange, PN 16

Differential pressure and flow controller (PN 16) AVPQ - return mounting, adjustable setting

2-Port Seat Valves with Flange, PN 16

Two-port seat valves

Differential pressure controller (PN 16) AHP - return mounting, adjustable setting

V311. Venta. Three-way Plug Valve, Flanged PN 16

Seated valves (PN 16) VF 2-2-way valve, flange VF 3-3-way valve, flange

2-port and 3-port seat valves, PN16

PRESSURE REDUCING VALVE RP45 (EN)

2-port seat valves PN25 with externally threaded connections

Three-port valves. Special versions with special stem sealing gland for: High temperature hot water C Thermo oils

Rotary valves HRB 3, HRB 4

BTV. Internally threaded 2-way control valve. Flow characteristics. Function

Technical data sheet. Type overview. Technical data. Safety notes. T5-R2.. Open-close en v Subject to changes 1 / 3

Products no longer available

AVP-F. p setting range (bar) Code No. 003H6200

Two-port valves, male threaded, PN25

Pressure Reducing Valve for steam RP 45

Pressure Independent Control Series

Pressure and Flow Control Valves DBGM, German and European Patents

Series 42 Self-operated Regulators Differential Pressure Regulators with Type 2424/Type 2428 Actuator (closing) Type Type 42-28

VB-7212 Series. Application. Features. Applicable Literature. 5/8" O.D., 45 SAE Flared Stem Up Open, Two-Way Valves General Instructions

2-Port and 3-Port Seat Valves with Female Thread, PN16

Series 44 Self-operated Pressure Regulators. Type 44-0 B Pressure Reducing Valve. ANSI version

2-port and 3-port valves PN 16

Differential pressure controller (PN 16) AVPL return mounting, adjustable setting

PRESSURE REDUCING VALVE RP45 (ANSI)

STAP. Differential pressure controllers DN , ANSI flanges

Automatic Balancing Valve Pressure difference controller with integrated flow limiter AB-PM DN

Overview of types. T5-R B2/R B2 en v Subject to changes 1 / 4. k vs (Sequence 2)

3-port seat valves with externally threaded connection, PN 16

VBS-9263 Series. Application. Features. Applicable Literature

STAG. Balancing valves Balancing valve with grooved ends DN

VB-7213 Series. Application. Features. Applicable Literature. 1/2" to 2" Screwed NPT Stem Up Open, Two-Way Valves General Instructions

Differential pressure controller (PN 16) AVPL - return mounting, adjustable setting

VB-7273 Series. Application. Features. Applicable Literature

VB-7211 Series. Application. Features. Applicable Literature. 1/2" to 1-1/4" Union End NPT Stem Up Open, Two-Way Valves General Instructions

VB-7263 Series. Application. Features. Applicable Literature

Automatic balancing valves ASV

Overview of types. Technical data. Safety notes

Pressure reducing valves Index

MZX. Three-Port Seat Valves SPECIFICIATIONS AND GUIDE TO SELECTION

STAP. Differential pressure controller DN

Overview of types. Technical data

STAP. Differential pressure controllers DN , ANSI fl anges

Differential pressure control and flow limiter AVPB/AVPB-F, PN 16

Rp [ ] Sv min. [ ] C215QP-B 15 1/ C215QP-D 15 1/ C220QP-F 20 3/ [ ]

T 2523 EN Type 2406 Excess Pressure Valve Self-operated Pressure Regulators ANSI version

STAD-D. Balancing valves Balancing valve for domestic water systems, DN Balancing valves

SV5 Safety Valve Installation and Maintenance Instructions

STAINLESS STEEL LOW PRESSURE REDUCING VALVE LPRV ELITE

TA-FUSION-P. Combined control & balancing valves Pressure independent combined balancing and control valves with independent EQM characteristics

Automatic balancing valves ASV

STA. Double regulating valves DN 15-50

Application Notes for Valve Sizing Sizing valves for steam service with the aid of sizing charts

Integral type Differential pressure flowmeter VNT Series

Technote. Frese PV-SIGMA Compact Dynamic Pressure and Flow Regulation. Description. Application. Operation. Features. Benefits.

Multifunctional Thermostatic Circulation Valve MTCV - Lead free brass

TBV-CM. Combined control & balancing valves for small terminal units For modulating control

Products no longer available

AVPQ/AVPQ-F, PN 16. Application

Upgradable balancing valves USV

VB-7323 Series. Application. Features. Applicable Literature. 1/2 to 2 Screwed NPT Three-Way Diverting Valves General Instructions

Overflow valves Type OFV REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Presetting Valve Type RA-N with Flange Connection

Ball Float Steam Trap UNA 45 MAX, UNA 46 MAX, UNA 46A MAX PN 40/Class 300 DN 40, 50, 65

Series 44 Self-operated Pressure Regulators. Type 44-1 B Pressure Reducing Valve. Type 44-6 B Excess Pressure Valve

Automatic balancing valves

Vortex Flow Meter Wafer or Flange Connection. - Steam - Liquid - Gas

DS MZ, MZF, MJF THREE-PORT SEAT VALVES

M45 ISO Ball Valve DN25 to 150 Installation and Maintenance Instructions

6-way characterised control valves DN15 and DN 20

Technote. Frese PVS - Dynamic Pressure and Flow Regulation Valve. Application. Features. Benefits.

STV / STVL. Danfoss STV series of balancing valves provide testing and balancing of circuit flow for hydronic heating or cooling systems.

HERZ - Compact Flow Controller with

HERZ - Compact Flow Controller with

Pressure independent control valve (PICV) FLOWMATIC

Self-operated Pressure Regulators Type 2405 Pressure Reducing Valve

CALEFFI. Pre-adjustable pressure reducing valves with self-contained cartridge series 01085/17 GB. replaces 01085/14 GB

Self-operated Pressure Regulators Type 2405 Pressure Reducing Valve

Pressure Reducing Valve for Steam Type 2333 A

Overflow valves Type OFV Type OFV-SS REFRIGERATION AND AIR CONDITIONING. Technical leaflet

6-way characterised control valves DN15 / DN 20 / DN 25

Radiator thermostats type RA2000, valve bodies type RA-FN (series D) and RA-G

Transcription:

Data sheet Seated valve for steam (PN 25) VFS 2 Two way valve, flange Description VFS 2 valve is a range of 2 port flanged valve for chilled water, PHW, MPHW, HPHW (low, medium or high pressure hot water) and steam applications. The valve is designed to be combined with following actuators: DN 15-50 AMV(E) 25 (SU/SD), AMV(E) 35, AMV(E) 56 (with clutch "On request") DN 65-100 AMV(E) 55, AMV(E) 56, AMV(E) 85, AMV(E) 86, AMV (E) 65x Features: ogarithmic characteristic Rangeability R= >100:1 by DN 20-100 Suitable for steam applications Main data: DN 15-100 k VS 0.4-145 m 3 /h PN 25 Down to close Medium: Circulation water/glycolic water up to 50 % / steam (max. Δp = 6 bar) Temperature: 2 ( 10 1) ) 200 C 1) At temperatures from 10 C up to +2 C use stem heater ogarithmic characteristic Flange PN 25 connections Compliance with Pressure Equipment Directive 2014/68/EU. Ordering Example: Two way valve, DN 15, k VS 1.6, PN 25, T max 200 C, flange connection - 1 VFS 2 DN 15 valve Code No.: 065B1513 Two way valve VFS 2 DN 15 k VS PN T max. Code No. (m 3 /h) ( C) 0.4 065B1510 0.63 065B1511 1.0 065B1512 1.6 065B1513 2.5 065B1514 4.0 065B1515 20 6.3 065B1520 25 200 25 10 065B1525 32 16 065B1532 40 25 065B1540 50 40 065B1550 65 63 065B3365 80 100 065B3380 100 145 065B3400 Spare parts stuffing box DN Description Code No. 15 20 25 32 40 50 65 80 100 Accessories Type Four PTFE rings Seal for valve cover Gland ring Washer Instructions Three PFTE rings Gland ring Instructions Stem heater 24 V AC/DC (AMV(E) 25, 35 and VFS 2 valves DN 15-50) Stem heater 24 V AC/DC (AMV(E) 56 and VFS 2 valves DN 15-50) Stem heater 24 V AC/DC (AMV(E) 85, 86 and and VFS 2 valves DN 65-100) Stem heater 24 V AC/DC (AMV(E) 55, 56, 655, 658, 659 and VFS 2 valves DN 65-100) Adapter AMV(E) 25 (SU/SD), AMV(E) 35 and VFS 2 DN 15-50 (for media temperatures over 150 C) Clutch (AMV(E) 56 and VFS 2 valves DN 15-50) 065B0001 065B0006 Code No. 065B2171 065Z7020 065Z7021 065Z7022 065Z7548 On request Danfoss 2018.02 VD.HC.4.02 1

Technical data Nominal diameter DN 15 20 25 32 40 50 65 80 100 k VS value m 3 /h 0.4 0.63 1.0 1.6 2.5 4.0 6.3 10 16 25 40 63 100 145 Stroke mm 15 40 Rangeability > 30:1 > 50:1 > 100:1 Control characteristic ogarithmic Cavitation factor z 0.5 0.5 0.5 0.5 0.5 0.5 0.4 0.3 0.3 eakage acc. to standard IEC 534 < 0.05 % of k VS Nominal pressure PN 25 Medium Circulation water/glycolic water up to 50 % /steam (max. p = 6 bar) Medium ph Min. 7, max. 10 Medium temperature C 2 ( 10 1) ) 200 Connections Flange ISO 7005-2 Materials Body and cover Ductile iron EN-GJS-400-18-T (GGG 40.3) Cone, seat and spindle Gland seal 1) At temperatures from -10 C +2 C use stem heater. Stainless steel Replaceable PTFE rings Ductile iron EN-GJS-400-15 (GGG 40) Pressure temperature diagram Valve characteristics-logarithmic DN 15-50: EN-GJS-400-18-T (GGG-40.3) PN 25 DN 65-100: EN-GJS-400-15 (GGG-40) PN 25 Capacity 2-way A AB Stroke Max. closing pressure 1) and recommended Δp 2) DN 15 Valve Stroke (mm) Actuator AMV(E) 25 [AMV(E) 25 SU/SD] 3) AMV(E) 35 AMV(E) 55 AMV(E) 56 AMV(E) 85, 86 AMV(E) 65x max. closing pressure 1) (bar) 25 [22 3) ] 25-25 4) - - 15 (k VS 4.0) 25 [16 3) ] 20-25 4) - - 20 25 [10 3) ] 13-25 4) - - 25 15 16 [5 3) ] 8-21 4) - - 32 9 [2.5 3) ] 5-12 4) - - 40 6 [2 3) ] 3-8 4) - - 50 3 [0.5 3) ] 2-5 4) - - 65 - - 4.5 3 13 4.5 80 40 - - 3 2 8 3 100 - - 1.5 1 5 1.5 Note: 1) Max. Δp is the physical limit of differential pressure the valve will close against. Max. Δp for stem application is 6 bar. 2) The recommended Δp is based on the generation of noise, plug erosion etc. Max. recommended Δp is 4 bar. If max. closing pressure is smaller than 4 bar than the recommended Δp is the same as closing Δp. 3) Values in parentheses [ ] are based on the force of the actuator AMV(E) 25 SU/SD only. 4) With stem connector (On request) 2 VD.HC.4.02 Danfoss 2018.02

Installation T max 150 C for AMV(E) 25 (SU/SD), 35 T max 200 C for other AMV(E) AMV(E) 25(SU/SD)/35 AMV(E) 55/56 AMV(E) 65x T max = 150... 200 C AMV(E) 25 (SU/SD), 35 Adapter for VFS 2 DN 15-50 AMV(E) 85/86 Valve mounting Before mounting the valve be sure that the pipes are clean and free from abrasion. It is essential that the pipes are lined up squarely with the valve at each connection and that they are free from vibrations. Always install the valve with the arrow on the body in the same direction as the flow. In order to avoid turbulence, which will affect the measuring accuracy, it is recommended to have a straight length of pipe up and down stream from the valve as shown (D - diameter of pipe). Install the motorized control valves with the actuator in a vertical or horizontal position in accordance to recommendations described in Installation above. Note that the actuator may be rotated up to 360 with respect to the valve body by loosening the retaining fixture. After this operation retighten. FVR/FVF AMV(E) eave sufficient clearance to facilitate the dismantling of the actuator from the valve body for maintenance purposes. 2D 6D Note that the actuator may be rotated up to 360 with respect to the valve body by loosening the retaining fixture. After this operation retighten. Note: Install a strainer upstream of the valve (e.g. Danfoss FVR/FVF) Disposal The valve must be dismantled and the elements sorted into various material groups before disposal. Danfoss 2018.02 VD.HC.4.02 3

Control valve sizing diagram for fluids Flow liquid with specific gravity of 1 Flow liquid with specific gravity different to 1 FOW Pressure drop kpa (100 kpa = 1 bar = ~10 m H 2 O) Specific gravity Examples: 1 For fluids with specific gravity of 1 (e.g. water) Design data: Flow rate: 6 m 3 /h System pressure drop: 55 kpa ocate the horizontal line representing a flow rate of 6 m 3 /h (line A-A). The valve authority is given by the equation: p1 Valve authority, a = p1+ p2 Where: Δp1 = pressure drop across the fully open valve Δp2 = pressure drop across the rest of the circuit with a full open valve The ideal valve would give a pressure drop equal to the system pressure drop (i.e. an authority of 0.5): If Δp1 = Δp2 p a 1 0.5 2 p 1 In this example an authority of 0.5 would be given by a valve having a pressure drop of 55 kpa at that flow rate (point B). The intersection of line A A with a vertical line drawn from B lies between two diagonal lines; this means that no ideally-sized valve is available. The intersection of line A A with the diagonal lines gives the pressure drops stated by real, rather than ideal, valves. In this case, a valve with k VS 6.3 would give a pressure drop of 90.7 kpa (point C): 90.7 hence valve authority = = 0.62 90.7 + 55 The largest valve, with k VS 10, would give a pressure drop of 36 kpa (point D): 36 hence valve authority = = 0.395 36 + 55 Generally, the smaller valve would be selected (resulting in a valve authority higher than 0.5 and therefore improved control). However, this will increase the total pressure and should be checked by the system designer for compatibility with available pump heads, etc. The ideal authority is 0.5 with a preferred range of between 0.4 and 0.7. 2 For fluids with specific gravity (S.G. ) different from 1 Design data: Flow rate: 6 m 3 /h of fluid, S.G. 0.9 System pressure drop: 10 kpa For this example, the left hand axis of the diagram must be ignored. Starting from the right hand axis, the flow rate of 6 m 3 /h is located (point E). The intersection of the diagonal line from point E with a vertical line from S.G. = 0.9 (point F) gives the starting point for the effective flow rate line G-G. The process then continues as for Example 1, so 10 kpa intersects G-G nearest to the k VS 16 diagonal. The intersection of G-G with k VS 16 gives a valve pressure drop of 12.7 kpa (point H). 4 VD.HC.4.02 Danfoss 2018.02

Control valve sizing diagram for steam Max. Δp in low pressure steam application variance from 0.5 bar to 6 bar (see page 2) mass flow of saturated water steam (kg/h) mass flow of superheated water steam (kg/h) Critical Pressure Drop (kpa) Superheat C Saturated Sream Temperature Absolute Inlet Pressure Critical Pressure Drop (kpa) Steam valve sizing is based on 40 % of the absolute steam pressure (immediately upstream of the valve), being dropped across the valve when fully open. At this condition the steam is travelling at or close to its critical velocity (approx. 300 m/s) and throttling will occur over the full valve stroke. If the steam is travelling slower than this then the first part of the valve stroke will merely increase the velocity of the steam without reducing the volumetric flow. Danfoss 2018.02 VD.HC.4.02 5

Control valve sizing diagram for steam (continued) 1 For saturated steam Design data: Flow rate: 1000 kg/h Absolute inlet pressure: 5 bar (500 kpa) - follow dashed line - The absolute inlet pressure is 500 kpa. 40% of this is 200 kpa. ocate the diagonal line corresponding to the pressure drop of 200 kpa (line A-A). Read the absolute inlet pressure on the lower left hand scale (point B), and draw a horizontal line across until it meets the pressure drop diagonal (A-A) at point C. From this point extend a vertical line upwards until it meets the horizontal line representing the steam flow of 1000 kg/h from point D. The intersection of this is point E. The nearest diagonal k VS line above this is line F-F with a k VS of 25 (point E ). If the ideal valve size is not available the next largest size should be selected to ensure design flow. The pressure drop through valve at the flow rate is found by the intersection of the 1000 kg/h line with F-F (point E ) and dropping a vertical; this actually hits the horizontal line for 500 kpa (point E ) inlet pressure at a pressure drop diagonal of 70 kpa. This is only 14 % of the inlet pressure and the control quality will not be good until the valve has partially closed. As with all steam valves this compromise is necessary since the next smaller valve would not pass the required flow (maximum flow would have been about 600 kg/h). The maximum flow for same inlet pressure is found by extending the vertical line (C-E) through point E until it crosses the k VS 25 line F-F (point E ) and reading off the flow (1700 kg/h). 2 For superheated steam Design data: Flow rate: 500 kg/h Absolute inlet pressure: 5 bar (500 kpa) Steam temperature: 190 C The procedure for superheated steam is much the same as for saturated steam, but uses a different flow scale which slightly elevates the readings according to the degree of superheat. - follow dotted line - As before, the diagonal pressure drop line A-A is located as before for 40 % of 500 (200 kg/h). The horizontal inlet pressure line through point B is now extended to the left to read off the corresponding saturated steam temperature at point G (150 C). The difference between the saturated steam temperature and the superheated steam temperature is 190 C - 150 C = 40 C. The superheated steam flow is found on the upper right hand scale, point H, and the diagonal line is followed down from here until it meets a vertical line from the steam temperature elevation (40 C) at point J. As before, the horizontal line through point B is drawn to cut line A-A at point C and the point where the vertical line from this point meets the horizontal line from point J is the operating point (point K). This horizontal line, J-K, is the corrected flow line. The nearest diagonal line above this is for k VS 10 (point K ). A vertical line dropped from the intersection of J-K with the 10 k VS line intersects the 500 kpa inlet pressure line (point K ) at a pressure drop diagonal of about 150 kpa. This is about 30% of the inlet pressure which will give reasonable control quality (compared to recommended ratio of 40%). 6 VD.HC.4.02 Danfoss 2018.02

Dimensions min. 150 min. 100 min. 150 min. 81 H 1 H 2 H 3 118.5 k H d n Adapter 065Z7548 VFS 2 (DN 15-50) + AMV(E) 25, 35 (SU/SD) min. 118 k H 1 VFS 2 (DN 15-50) + AMV(E) 56 + clutch "On request" DN H H 1 k d n mm (number) Valve weight (kg) 15 130 237 383 65 14 4 3.6 20 150 237 383 75 14 4 4.3 25 160 237 383 85 14 4 5.0 32 180 259 405 100 18 4 8.7 40 200 259 405 110 18 4 9.5 50 230 259 405 125 18 4 11.7 d n VFS 2 (DN 65-100) + AMV(E) 55, 56 VFS 2 (DN 65-100) + AMV(E) 65X VFS 2 (DN 65-100) + AMV(E) 85, 86 DN H 1 H 2 H 3 k d n Valve weight mm (number) (kg) 65 290 484 525 568 145 18 8 23.0 80 310 503 544 587 160 18 8 28.1 100 350 530 571 614 190 22 8 40.7 Danfoss 2018.02 VD.HC.4.02 7

Data sheet VFS 2 Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary eady agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved. 8 VD.HC.4.02 Danfoss DHS-SRMT/SI 2018.02