ScienceDirect. Helium contamination through polymeric walls

Similar documents
Cryocooler-Based Helium Recovery Plant for Applications Requiring Gas or Liquid with Extreme Purity

ATL. Take Control of your Helium Supply. Advanced Technology Liquefier The next generation of helium recycling

INTRODUCTION. The Quantum Technology system has the following advantages:, as it does not need plastic gas-bags which are volume-consuming,

Procedure of Xenon Transfer

PRELIMINARY TEST RESULTS ON A CLOSED-LOOP CONTAMINANT REMOVAL SYSTEM FOR PROCESSING OF METALLIC MELTS

Available online at Procedia Engineering 45 (2012 )

Chapter 8: Cryo-sorption pumps

Linde Cryogenics. Helium Recovery Systems.

The Polyethylene Casing as Diffusion Barrier for Polyurethane Insulated District Heating Pipes

Helium recovery at the National High Magnetic Field Laboratory

Helium Mass Spectrometric Leak Detection In Large Size Process Plants

Experimental Investigation on Stirling type Thermally Coupled Three Stage Pulse tube Cryocoolers with U type Configuration

Membrane modules for nitrogen and oxygen generator systems. Technology Overview ENGINEERING YOUR SUCCESS.

An Investigative and Synoptic Review on Helium Liquefaction Using a Commercial 4 K Gifford- McMahon Cryocooler

DEVICES FOR FIELD DETERMINATION OF WATER VAPOR IN NATURAL GAS Betsy Murphy MNM Enterprises 801 N. Riverside Drive Fort Worth, Texas 76111

Detector Carrier Gas Comments Detector anode purge or reference gas. Electron Capture Nitrogen Maximum sensitivity Nitrogen Argon/Methane

AN EXPERIMENTAL INVESTIGATION ON HELIUM LIQUEFACTION USING TWO-STAGE GIFFORD McMAHON CRYOCOOLER

Development of a high vacuum sample preparation system for helium mass spectrometer

maintaining storage tank dissolved oxygen levels utilizing gas transfer membranes

Finding leaks in Main Cryogenic Heat Exchangers without shutdown

The Principles of Vacuum Technology

VIC offers a variety of Calibrated Gas Leaks

Procedia Engineering Procedia Engineering 2 (2010)

Load Responsive Multilayer Insulation Performance Testing

Available online at ScienceDirect. Physics Procedia 67 (2015 )

Available online at ScienceDirect. Procedia Engineering 84 (2014 )

Introduction of Vacuum Science & Technology. Diffusion pumps used on the Calutron mass spectrometers during the Manhattan Project.

Earlier Lecture. In the earlier lecture, we have seen Kapitza & Heylandt systems which are the modifications of the Claude System.

Recovery of helium from rejected gas streams in Natural gas processing [1, 2, 3].

Memorandum Background: Results and Discussion:

CHAPTER 16 %UHDWKLQJ*DV0L[LQJ3URFHGXUHV

MASS FLOW SYSTEMS MASS FLOW MEASURING, CONTROLLING AND BLENDING SYSTEMS

What I have learned about SF 6 gas testing.a Practical explanation

Comparative Study of Oxygen Permeation Through Polymers and Gas Barrier Films

Experimental Research on Oxygen-enriched Air Supply System for Gasoline Engine

how to meet today s dissolved oxygen specifications with degasification membranes

APPLICATION NOTE. GC Integrated Permeation Device

INSTRUMENTS A THERMAL MASS FLOW SENSOR USING A CONSTANT DIFFERENTIAL TEMPERATURE ABOVE THE AMBIENT GAS TEMPERATURE

Gases and welding distributors continue

Experimental Analysis on Vortex Tube Refrigerator Using Different Conical Valve Angles

Development of High Efficiency 4K Two-Stage Pulse Tube Cryocooler

Advantages of Carrier Gas Leak Detection using Novel Helium or Hydrogen Leak Detectors with Specific Sensor Types

Influence of Ambient Temperature on Performance of a Joule-Thomson Refrigerator

METHOD 3C - DETERMINATION OF CARBON DIOXIDE, METHANE, NITROGEN, AND OXYGEN FROM STATIONARY SOURCES

Oxygen Contamination

Generating Calibration Gas Standards

Cryogenics is the science of ultra low temperatures. Low temperatures are achieved by the liquefaction of gases.

Development of high pressure-high vacuum-high conductance piston valve for gas-filled radiation detectors

Helium-Liquefaction by Cryocooler for High-Field Magnet Cooling

Experiment 18 Properties of Gases

Oil-Lubricated Compressors for Regenerative Cryocoolers Using an Elastic Membrane

Storage and transfer of cryofluids

Available online at ScienceDirect. Procedia Engineering 112 (2015 ) 40 45

Major Design Features

THE GUIDE TO MEMBRANE NITROGEN GENERATORS

Laser Gases and Support

The Helium Leak Detector

Plasma. Argon Production Helium Liquefaction Truck Loading Pure Gas Bottling

HYDROGEN - METHANE MIXTURES : DISPERSION AND STRATIFICATION STUDIES

Available online at ScienceDirect. Physics Procedia 67 (2015 )

Experimental Verification of Integrated Pressure Suppression Systems in Fusion Reactors at In-Vessel Loss-of -Coolant Events

Micro Channel Recuperator for a Reverse Brayton Cycle Cryocooler

Automatic Permeability Testing: The Challenges and Solutions Author: Alyce Hartvigsen, PBI-Dansensor A/S, Ringsted, Denmark

AC : MEASUREMENT OF HYDROGEN IN HELIUM FLOW

Current Trends in Leak Testing Technology. A. P. Fonseca, H. P. Marques, A. M. C. Moutinho and O. M. N. D. Teodoro

The Origin and Time Dependence of the Amount and Composition of Non- Constituent Gases Present in Crystal Growth Systems

Vacuum. Dry Turbo Pumping Stations. Roughing Pumps for 1 K Helium Pots and Lambda Refrigerators. Hermetically Sealed Pumps for He3 Recirculation

Sampling Considerations for Equilibrium Dissolved Oxygen [DO] Sensors


Gas Vapor Injection on Refrigerant Cycle Using Piston Technology

29th Monitoring Research Review: Ground-Based Nuclear Explosion Monitoring Technologies

LEAP CO 2 Laboratory CO 2 mixtures test facility

Microscopy Cryogenic WORKSTATION. Performance by Design

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs.

Effect of Coiled Capillary Tube Pitch on Vapour Compression Refrigeration System Performance

Chapter 6 Leak detection

On-Stream Tightness Testing of Vacuum Process Installations

RC102 & RC110 Sample in Vacuum Continuous Flow Cryogenic Workstation Cryostats

How To Use Getters and Getter Pumps

Ignition Sensitivity of Nonmetallic Materials in Oxygen-Enriched Air NITROX : A Never Ending Story in SCUBA Diving?

M-06 Nitrogen Generator (Nitrogen Making Machine)

CFD Simulation and Experimental Validation of a Diaphragm Pressure Wave Generator

Gases&Technology. Measurement of Impurities in Helium Using the Dielectric Barrier Discharge Helium Ionization Detector. FEATURE.

Columbus Instruments

11/22/ (4) Harmonization: <846> SPECIFIC SURFACE AREA

Technical Data Sheet MF010-O-LC

Title: Choosing the right nitrogen rejection scheme

Detecting Hydrogen in Helium Streams. Samuel Goodman. Pittsford Mendon High School. Rochester, New York. Advisor: Dr.

TIGHTNESS. Glass sealing Thanks to our glass-sealing technology, ODU products can meet the most demanding tightness requirements.

DETERMINATION OF TETRAHYDROTHIOPHENE IN AMBIENT AIR BY GAS CHROMATOGRAPHY WITH A PFPD DETECTOR COUPLED TO A PRECONCENTRATION TECHNOLOGY

T208VR Series Tank Blanketing Vacuum Regulator

Dr. Thiedig DIGOX 5 CO 2. In-line measurement of CO 2 for constant product quality. Anlagen- und Analysentechnik

Development of Helium Leak Testing System and Procedure for testing Welds of Steam Generator

Determination of Air Density with Buoyancy Artefacts

KATEDRA MATERIÁLOVÉHO INŽENÝRSTVÍ A CHEMIE. 123MEAN water vapor transport

CHEMISTRY - CLUTCH CH.5 - GASES.

Manual. Online Degasser DDG-75. Manual Degasser DDG-75 April DURATEC Analysentechnik GmbH Rheinauer Strasse 4 DE Hockenheim Germany

CHAPTER 3 RESULTS AND DISCUSSION

Characterization and Modeling of Wafer and Die Level Uniformity in Deep Reactive Ion Etching (DRIE)

CO 2 and O 2 scrubbers

Transcription:

Available online at www.sciencedirect.com ScienceDirect Physics Procedia 67 (2015 ) 141 146 25th International Cryogenic Engineering Conference and the International Cryogenic Materials Conference in 2014, ICEC 25 ICMC 2014 Helium contamination through polymeric walls M.Gabal a*, M.P. Lozano b, A.Oca c, M.P. Pina a, J.Sesé a,c. Rillo d a INA, Universidad de Zaragoza,Zaragoza 50018,Spain b Departamento de Física de la Materia Condensada, Universidad de Zaragoza,Zaragoza 50009,Spain c C.P.G.E. Air Liquide España, Madrid 28021, Spain d ICMA,CSIC-Universidad de Zaragoza,Zaragoza 50009,Spain Abstract The concentration of impurities in helium gas is an important parameter for a recovery and liquefaction plant. A low level of impurities is necessary to maintain an optimum liquefaction rate in any kind of liquefier. The main origin of the impurities is the air contamination that enters into the helium mainstream at some point in the recovery cycle. In this work we have: i) identified the main sources for impurities in an experimental helium recovery plant, ii) quantified the contamination rate and iii) proposed a mitigation strategy. An analysis of the He impurities composition reveals a nitrogen/oxygen ratio different to the one existing in air. This observation is in accordance with the permeability values for nitrogen and oxygen through the polymer materials used in the plant. Experimental on line measurements for oxygen content in the He mainstream with sensitivity below 1 ppm, have been performed after recirculation through metal and polymeric pipelines, respectively, to validate our hypothesis. In addition, the dependence of the impurities concentration with the He retention time in the recovery gas bag has been evaluated. Finally some operational recommendations are given for practical applications. 2015 2014 The The Authors. Published Published by Elsevier by Elsevier B.V. B.V. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). Peer-review under responsibility of the organizing committee of ICEC 25-ICMC 2014. Peer-review under responsibility of the organizing committee of ICEC 25-ICMC 2014 Keywords: Helium Liquefaction Plant, Helium Recovery, Permeation Process, Helium Impurities, Oxygen Diffusion * Corresponding author. Tel.: +34-976-761-228. E-mail address: mgabal@unizar.es 1875-3892 2015 The Authors. Published by Elsevier B.V. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). Peer-review under responsibility of the organizing committee of ICEC 25-ICMC 2014 doi:10.1016/j.phpro.2015.06.025

142 M. Gabal et al. / Physics Procedia 67 ( 2015 ) 141 146 1. Introduction During the last years, the low temperature community has suffered periods in which it has been difficult to get liquid helium from commercial suppliers. Indeed the worldwide supply of helium cannot be guaranteed because it is a scarce and fossil element with a small amount of sources around the planet [1]. Thus, liquefaction and reutilization of the helium once it evaporates emerge as one of the most adequate strategies for laboratory or industrial applications. A typical configuration for a helium recovery plant is shown in Fig. 1. An undetermined number of cryostats and transport dewars are connected to the metallic pipes of the recovery line that could be extended over several labs located on different buildings. The evaporated helium flows through the recovery line into the gas bag that acts as a temporary storage buffer. The compressor enables the He pumping and storage on the gas cylinders at high pressure (2 10 7 Pa). One of the main problems deals with the potential contamination of recovered He by other permanent gases existing in the atmosphere (namely nitrogen, oxygen, Fig. 1. Scheme of a general liquefaction-recovery helium plant. Blue lines: metallic pipes, blue dashed line: Liquid helium transfer, red line: helium gas connection pipes to recovery line, material in study at this report. Main elements: Transport dewars or instrument cryostats, gas bag, a compressor, high pressure storage bottles, a system to purify and a system to liquefy the helium. water, or carbon dioxide) due to the permeability properties of the pipelines. Consequently, a purification step is mandatory due to the fact that He purity is the determining performance factor for any liquefier. In medium-pressure recovery systems without gas bag and with only metallic pipework, the total content of impurities can be lowered to tens of ppm. In those cases the helium gas can be cleansed by liquid nitrogen traps or heated getter systems [2]. In high-pressure recovery systems, with a compressor and gas bag, a more powerful purification step is needed. In fact, large-scale Collins liquefiers have internal purifiers; whereas small scale liquefiers based on cryocoolers require external counterparts [3]. The case of the liquefaction-recovery plant of Universidad de Zaragoza analysed in this work has a 487 STPm 3 of total helium capacity, the gas bag has a volume of 10 m 3, the compressor has a pumpability of 5.56 10-3 STPm 3 s -1 at 1.5 10 7 Pa, the storage cylinders have a volume of 1.6 m 3, the purifier is an ATP30, and the liquifiers are 2 ATLs [4]. The amount of impurities that enter into the helium recovery circuit has to be controlled and maintain at the minimum level, to ensure the liquefaction rate. Otherwise, the purifier will be rapidly saturated. The gas permeation through polymeric membranes is identified as the main source of He contamination in a recovery plant. The major contamination focus is the gas bag used as storage flexible tank with tunable capacity (i.e. up to several cubic meters). Less notorious is the contribution of the polymeric tubes used for the connection of the instruments or

M. Gabal et al. / Physics Procedia 67 ( 2015 ) 141 146 143 transport dewars to the metallic recovery line. Due to the harmful effects on vacuum technology, previous studies have been devoted to the study of gas permeation through different materials [5], [6]. 2. Experimental measurements 2.1. First considerations We have measured the purity of the helium in our recovery plant when it arrives to the storage bottles using a gas chromatography instrument from GOW-MAC, Model 295R DID. The result shows that the helium in the storage bottles is typically 99.92 % pure, and the main impurities are in fact nitrogen and oxygen from the atmosphere. The impurities composition is 63.01 % nitrogen, 36.95 % oxygen and 0.05 % carbon dioxide. As it was expected, the N 2 :O 2 molar ratio notably differs from the air value, 1.7 versus 3.7. This observation agrees with the differences in permeation behavior of nitrogen and oxygen through polymers [7]. The mechanism of gas permeation through polymeric films could be described by the solution-diffusion model, in which permeants dissolve in the membrane material and then diffuse through the membrane down a concentration gradient. The permeants are separated because of the differences in the solubilities of the materials in the membrane and the differences in the rates at which the materials diffuse through the membrane. Accordingly, the permeation flow rate of component i, F i, through the membrane (expressed in STPm 3 s -1 ) can be calculated as follows [8]: A P F K (1) d Where K is the membrane permeability, and is a measure of the membrane s ability to permeate gas, A is the permeation area (expressed in m 2 ), d is the membrane thickness (expressed in m) and P is the driving force for component i permeation (expressed in hpa). The membrane permeability can be written as: K D S (2) Where D is the concentration-independent, diffusion coefficient (expressed in m 2 /s) which reflects the mobility of the individual molecules in the membrane material and S is the gas sorption coefficient (expressed in STPm -3 hpa -1 ) which reflects the number of molecules dissolved in the membrane material. This work is mostly focused on the analysis of the O 2 concentration in the helium mainstream. The N 2 concentration from the results above is assumed to be 1.7 folds the encountered O 2 values. The concentration of other impurities is practically negligible. Continuous oxygen monitoring is carried out by means of a Zirconia based sensor (SERVOMEX: Servopro Multiexact) that operates with 0.4 slpm as flow rate with a detection limit below 1 ppm. Our simple model for the study of oxygen contamination in the He recovery plant is depicted in Fig. 2. As it can be observed, a pure He stream is pumped via stainless-steel and polymeric pipelines and the O 2 concentration is continuously measured downstream. Fig. 2. Schematic representation of how the oxygen contamination enters the helium flow. Gray parts: metallic pipe, blue parts: polymeric pipe. The atmosphere is the source of the oxygen flow

144 M. Gabal et al. / Physics Procedia 67 ( 2015 ) 141 146 These, experimental values are correlated with the permeation flow of oxygen through the polymeric wall, F O2, and the total helium flow in the main stream, F He according to the equation (3) in which we assume that F O2 << F He F 2 10 F O 6 ppm [ O ] 2 (3) 2.2. Polymeric pipelines characterization He Usually, the connection of instruments and dewars to the recovery line is made via inexpensive and easy to handle polymeric tubing. In this work, silicone and natural rubber based pipelines have been studied due to they are among the most commonly used. For the experiments, a bundle of bottles containing high purity helium (99.999%) have been connected to a forward pressure controller to ensure 1448 mbar as absolute pressure upstream. Different pipelines, varying length, diameter and wall thickness and polymer nature have been tested at helium flow rate of 0.4 slpm; a typical value for the evaporation rate in a transport Dewar. Table 1 shows the so obtained permeability values where literature data for similar polymers have been also included for comparison purposes. The results reveal a reasonable agreement between our experimental permeability data and those already published. This observation underlines the goodness of our hypothesis about helium contamination sources. As it can be observed, natural rubber and polyurethane based polymer tubes are the most adequate among the tested to reduce the O 2 impurities content, but the polyurethane, due to its stiffness, is inadequate for an easy connection. It is worthwhile to mention the relative high stabilization periods to attain stationary values for the oxygen concentration in the He main stream, up to 18 hours for natural rubber 6 mm thick. A possible explanation relies on the pipelines storage conditions rendering to O 2 saturation levels of the polymers corresponding to equilibrium at atmospheric conditions. In fact, additional experiments to study the oxygen contamination dependence with the helium flow were performed (see Fig. 3) with a silicone pipeline (2 m length, 3 mm thick and 16 mm as internal diameter). As it was expected, the stabilization period decreases monotonically with the He flow rate due to the sweep effect on the adsorbed species on the internal polymeric walls. From the linear fitting and equation 3, an average O 2 permeation flow rate through the silicone membrane 3 mm thick of 1.53 10-9 STPm 3 s -1, has been obtained. Similarly, the experimental O 2 permeability value is 215 10-15 (STPm 3 ms -1 m -2 hpa -1 ) in reasonable agreement with published data (76-460 10-15 (STPm 3 ms -1 m -2 hpa -1 ) reported in [10], 375 10-15 (STPm 3 ms -1 m -2 hpa -1 ) reported in [7]. Table 1. O 2 concentration measurements in the helium mainstream due to air permeation through the connection pipes to recovery line at room temperature. Obtained permeability values literature data (*Sources are:[7], [9]). Material Dimensions [Length (m); Diameter (mm); Thickness (mm)] Steady State O 2 concentration (ppm) Permeability K (10-15 STPm 3 ms -1 m -2 hpa -1 ) Silicone Rubber [0.5; 16; 3] 62.5 234.4 Silicone Rubber Silicone Rubber Natural Rubber Natural Rubber Polyurethane Stainless Steel Flexible [2; 16; 3] [5; 16; 3] [2; 22; 6] [4; 22; 6] [2.6; 8; 1] [2; 28; 1] 266 631 2.13 3.07 1.07 0.5 249.4 236.7 2.90 2.09 0.51 - Average Permeability K (10-15 STPm 3 ms -1 m -2 hpa -1 ) 240.2 ± 6.6 2.5 ± 0.4 0.51 Literature Permeability K (10-15 STPm 3 ms -1 m -2 hpa -1 )* 375 17.2 25.1

M. Gabal et al. / Physics Procedia 67 ( 2015 ) 141 146 145 300 250 200 O 2 (ppm) 150 100 50 Fig. 3. Evaluation of O 2 contamination due to polymeric pipelines as a function of the helium flow rate: left) experimental set-up; right): experimental results. Moreover, to validate the O 2 contamination source, a blank experiment was also performed with stainless steel pipelines (see table 1). In this particular case, the registered O 2 concentration values were always below the detection limit of the SERVOMEX. Accordingly, stainless steel non porous flexible tubing seems the most adequate to avoid He contamination in the recovery line at the expense of higher unitary cost compared to polymeric counterparts. 2.3. Gas bag characterization. 0 0 0,5 1,0 1,5 2,0 2,5 3,0 1/F He (min/l) The gas bag in our recovery system is fabricated in J-22 material, a modified vinyl based polymer, including up to 3% wt. polyvinylidene chloride, and polymeric non-migrating plasticizers (http://www.flexiliner.com/specsheetj22.pdf). According to the supplier specifications, the He permeability in J-22 is 644,7 10-15 (STPm 3 ms -1 m -2 hpa -1 ) at 340 K. Thus, the estimated He flow rate permeating through J-22 is 7.83 10-6 (STPm 3 s -1 ), circa 250 (STPm 3 ) of He losses per year. Fig. 4. Evaluation of O 2 contamination due to the gas bag during filling-evacuation cycles: left) experimental configuration note that the instruments are connected to the recovery line using metallic pipes; right) overpressure (black line) and height (red line) of the gas bag with time on stream, note that the compressor turns on for He pumping to the gas cylinders at 1700 mm and 0.75 mbarg as height of the bag and gas overpressure, respectively. The experimental set up used to evaluate He contamination in the gas bag is shown in Fig. 4. The parameter used to control the process of bag filling is the height of the bag. For such purposes, a non-contact ultrasonic distance measurement sensor is deployed. The high-pressure compressor (2 10 7 Pa) and the O 2 analyzer turn on simultaneously when the height of the bag reaches the upper limit (1700mm) (Fig. 4 right) In this work, several experimental conditions have been tested to simulate different He recovery rates. Fig. 5 shows the oxygen concentration values as a function of He flow rate from the instruments; that means, as a function of He retention time in the gas bag. The obtained data follow the expected linear trend from equation (3), with an average O 2 flow

146 M. Gabal et al. / Physics Procedia 67 ( 2015 ) 141 146 rate permeating through J-22 of 2.38 10-8 (STPm 3 s -1 ). This constant source of He contamination by O 2 depends on the gas bag material, dimensions (total area and thickness) and pressure driving force. Therefore, the proper design for a recovery plant implies a gas storage buffer with minimum dimensions but large enough to handle with the high flow rate occurring during helium transfers. From the average O 2 flow rate, F O2, and using equation (1), an O 2 permeability in J-22 material of 9.20 10-15 (STPm 3 ms -1 m -2 hpa -1 ) has been estimated, rather similar to the evaluated for natural rubber (see table 1). 3. Conclusions Fig. 5. Evaluation of O 2 contamination due to storage in the gas J-22 bag as a function of retention time. The gas permeation through polymeric walls is the main source for contamination in a helium recovery plant. Firstly, the gas bag, used as temporary storage buffer, plays a critical role in the high-pressure recovery system. This work demonstrates that its design (size and material) is controlling the purity of the recovered helium. Thus, the size should be the lowest as possible, once the plant requirements are fulfilled, to minimize the exposed area for air permeation Secondly, the air permeation through polymeric pipelines used as connectors between dewars/instruments and the recovery line is also responsible for He contamination by O 2. Among the polymer type tubing tested, natural rubber provides the best results, but still is insufficient to preserve He purity. On the other hand, stainless-steel flexible tubing is the most adequate to avoid contamination in the recovery circuir at the expense of higher cost. Acknowledgements The authors gratefully acknowledge the financial support from the Spanish Ministry of Economy and Competitiveness through the INNPACTO project IPT-2012-0442-420000 and the facilities provided by Servicio General de Apoyo a la Investigación-SAI, Universidad de Zaragoza. References [1] K. H. Kaplan, Helium shortage hampers research and industry, Phys. Today, vol. 60, pp. 31 32, 2007. [2] M. P. Lozano, M. Gabal, J. Sesé, M. P. Pina, and C. Rillo with ICEC 25 ICMC 2014, Purification of recovered Helium with low level of impurities: evaluation of two different methods, Physics Procedia. 2014. [3] Quantum Design s Advanced Technology Liquefiers (http: //www.qdusa.com/products/helium-liquefiers.html). 2013. [4] ATLs and ATPs are products developed by Quantum Design (http: //www.qdusa.com), in collaboration with GWR Instruments, Universidad de Zaragoza and Consejo Superior de Investigaciones Científicas (CSIC). 2013. [5] P. Sturm, M. Leuenberger, C. Sirignano, R. E. M. Neubert, H. A. J. Meijer, R. Langenfelds, W. A. Brand, and Y. Tohjima, Permeation of atmospheric gases through polymer O-rings used in flasks for air sampling, J. Geophys. Res., vol. 109, no. D4, 2004. [6] S. J. Schowalter, C. B. Connolly, and J. M. Doyle, Permeability of noble gases through Kapton, butyl, nylon, and Silver Shield, Nucl. Instruments Methods Phys. Res. Sect. A: Accel. Spectrometers, Detect. Assoc. Equip., vol. 615, pp. 267 271, 2010. [7] R. W. Baker, Membrane Technology and Applications. Wiley, 2004. [8] W. G. Perkins, Permeation and Outgassing of Vacuum Materials, J. Vac. Science and Technology, vol. 10, no. 4. pp. 543 556, 00-1973. [9] C. Shih-Hsiung, Y. Kuang-Chang, H. Shih-Liang, and L. Juin-Yih, Gas transport properties of HTPB based polyurethane/cosalen membrane, Journal of Membrane Science, vol. Volume 173. 10-Jul-2000. [10] R. N. Peacock, Practical selection of elastomer materials for vacuum seals, J. Vac. Sci. & Technol., vol. 17, pp. 330 336, 1980.