Installation, commissioning and servicing instructions

Similar documents
Installation, commissioning and servicing instructions

Installation, commissioning and servicing instructions

CALEFFI. Pre-adjustable pressure reducing valves with self-contained cartridge series 01085/17 GB. replaces 01085/14 GB

Pre-adjustable pressure reducing valves with self-contained cartridge

Installation, commissioning and servicing instructions

High Performance BSP Dial Up Pattern Pressure Reducing Valve

Tempering valve for solar and instantaneous applications Installation, commissioning and servicing instructions 2522HP series

CALEFFI. Inclined pressure reducing valves series 01024/17 GB. replaces 01024/14 GB

ACCREDITED H series Inclined pressure reducing valve sizes DN 15 (1/2 ) and DN 20 (3/4 )

Art PRESSURE REDUCER

TECHNICAL CATALOGUE PRESSURE REDUCING VALVES EUROPRESS

TECHNICAL CATALOGUE PRESSURE REDUCING VALVES EUROPRESS

TEC 1/2 3/4 DN A B C 32,25 32,25 F Kg/cm 2 bar LBS - psi

553 Series.

ACCREDITED. Function. series 5360/

valves Total Control.

Filling valves AL, ALM Series Automatic filling units ALOMDIW, ALOMDNW Series

Installation, commissioning and servicing instructions

Pressure reducing valves

Function. Code Automatic filling units with pressure gauge connection Size 1/2 Code Automatic filling units with pressure gauge Size 1/2

SEQUENTIAL SHOWER VALVE INSTRUCTION MANUAL PLEASE LEAVE THIS MANUAL WITH THE END USER

DN 1/2" to 2" Female BSP + 0 C C Max Pressure : 16 Bars Specifications : Stainless steel removable filter Female / Female With draining valve

Overview of types. T5-R B2/R B2 en v Subject to changes 1 / 4. k vs (Sequence 2)

TEC 1/2 3/ /4 1 1/ /2 3 4 DN A B 125,5 125,

differential pressure regulating valve - threaded


Materials : Brass body dezincification-resistant up to DN1 1/4

PRESSURE REDUCING VALVE EUROBRASS 143 FF

Pre-adjustable pressure reducing valves

PRESSURE REDUCING VALVE EUROBRASSBLU CR FF

Technical data sheet. Type overview. Technical data. Safety notes. T5-R2.. Open-close en v Subject to changes 1 / 3

Pressure independent control valve (PICV) FLOWMATIC

Thermocirc Installation and Maintenance Instructions

SRV66 Sanitary Pressure Reducing Valve

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

INSTALLATION INSTRUCTIONS

CAST IRON SAFETY VALVE TYPE 6301

Materials : Brass body dezincification-resistant

Two-port valves, male threaded, PN25

WATER PRESSURE REDUCER (SBD)

SINGER MODEL 106/206-RPS-L&H

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

V311. Venta. Three-way Plug Valve, Flanged PN 16

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron body

Twin & Triple Control Concealed Thermostatic Shower Valve

MZX. Three-Port Seat Valves SPECIFICIATIONS AND GUIDE TO SELECTION

Materials : Stainless steel ASTM A351 CF8M

Thermostatic Mixing Valves 61022CPB & 61028CPB Intamix Pro V

2-port seat valves PN25 with externally threaded connections

PRESSURE REDUCING VALVES

Overview of types. Technical data. Safety notes

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron body

Pressure reducing valves Index

Pressure Relief Valve DHV 718

FULL FLOW GAS BALL VALVES: LONDON EN 331 APPROVED. GAS BALL VALVES

C 10 Pressure Reducing Valve

POP Safety Valve. POP Safety Valve INTRODUCTION DEFINITIONS

OPERATING INSTRUCTIONS

Type overview. R B2 en-gb subject to changes 1

Dival 500 Pressure Regulators

Model GP PRESSURE REDUCING VALVE Installation & Operation Manual

Intamix Thermostatic Mixing Valve

DN 3/8" to 4" Female BSP - 10 C C Max Pressure : 16 Bars up to DN 2 Specifications : Removable stainless steel filter Female / Female

Installation Guide - C01202 & C01203 Thermostatic Mixing Valve TMV2

M45 ISO Ball Valve DN25 to 150 Installation and Maintenance Instructions

Pressure reducing valves Series DRV/DRVM - DRVN/DRVMN

Technote. Frese ALPHA cartridges. Application. Features. Benefits.

Self-help Temperature Adjustment

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.

Installation Instructions and User Guide 15mm & 22mm Thermostatic Mixing Valve

Reduce pressure zone device suitable for high and medium hazard rated applications BSP screwed connections

PRV4 PT Pressure Reducing Valve

WW-720. Pressure Reducing Control Valve

KTM 50 (DN ) Installation, maintenance and operating instructions

Mounting and operating instructions EB 2530 EN. Self-operated Pressure Regulator. Pressure Reducing Valve Type M 44-2

Mounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator

6301 TYPE CAST IRON SAFETY VALVES

HERZ-Motorised flow controler

TBV-CM. Combined control & balancing valves for small terminal units For modulating control

Mounting and Operating Instructions EB 2555 EN. Self-operated Pressure Regulators. Pressure Reducing Valves Type 50 ES Type 50 EM.

Rp [ ] Sv min. [ ] C215QP-B 15 1/ C215QP-D 15 1/ C220QP-F 20 3/ [ ]

Pressure relief valve DHV 716 set range: 0,5-10,0 bar

AVPQ/AVPQ-F, PN 16. Application

PRESSURE REDUCING VALVE RP45 (EN)

Seated valves VRB 3, VRG 3

WW-720. Pressure Reducing Control Valve

Overview of types. Technical data

Installation, operation & maintenance manual - original version

Scald Protection Three-Way Thermostatic Mixing Valve

Seated valves (PN 6) VL 2 2-way valve, flange VL 3 3-way valve, flange

Products no longer available

776 Cryogenic Safety Valve

Manual Actuated Boiler Blowdown Valves

Mainsboost Installation, Operation & Maintenance Instructions

Deluge Optimo Shower valve and kit 10032CP

HAYWARD FLOW CONTROL Series PBV Back Pressure Valve and Series RPV Pressure Relief Valve INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS

Pressure Independent Control Series

PV4 and PV6 Piston Valves

WW-730. Pressure Sustaining/Relief Control Valve

Transcription:

488.03 www.reece.com.au Pressure reducing s Installation, commissioning and servicing instructions Function Pressure reducing s are installed in residential water systems to reduce and stabilise inlet pressure from the water mains supply which is generally too high and variable for domestic appliances to function properly. These s can also be used to control inlet pressure to domestic hot water storage. The Tomson PRV series have been specifically designed and manufactured to meet the requirements of AS37.:00 Valves primarily for use in warm and hot water systems - P. : Control s. Product range AS 37. C of C 0467 Straight Pressure reducing DN (/ ), DN 0 (3/4 ) and DN ( ) Female connections (ISO 7/) Right-angle Pressure reducing DN 0 (3/4 ) Female connections (ISO 7/) Technical specifications Materials: Body: - Straight: dezincification resistant alloy CR EN 6 CW60N, chrome plated - Right-angle: dezincification resistant alloy CR EN 6 CW60N Cover: PA6G30 Control spindle: stainless steel Cartridge: PPS-PSU Components: brass EN 6 CW67N Diaphragm: EPDM Seals: EPDM Strainer: stainless steel Performance: Pressure setting range: 00 600 kpa (Straight); 00 kpa (Right-angle) Factory setting: 30 and 00 kpa Max. inlet pressure: 000 kpa Max. working temperature: 80 C Medium: water Complies with: AS 37.

AS 37. WMKA 0467 33 Series Pressure range: 00 600 kpa Max inlet pressure 600 kpa Flow rate: 30 @ 00 kpa 30 @ 600 kpa Max temperature: 60 C Dimensions B C D AS 37. WMKA 0467 33 Series Pressure range: 00 600 kpa Max inlet pressure 600 kpa Flow rate: 30 @ 00 kpa 30 @ 600 kpa Max temperature: 60 C A A E Prod. code Ref. code Set (kpa) DN A B C D E Mass (kg) 9097 3344H TMS 9098 334H TMS 30 30 904090 334H TMS 90409 33H TMS 00 00 / 74, Ø 46 79 0,4 0 3/4 74, Ø 46 84, 0,46 9099 3364H TMS 30 90409 336H TMS 00 74, 3 Ø 46 9 0,4 B D C Pressure drop diagram Under following conditions: - Inlet pressure: 800 kpa - Outlet set pressure: 00 kpa p (kpa) / 3/4 p (m w.g.) 0 0 0 9 00 90 8 80 7 6 70 60 4 0 40 3 30 0 0, 0, 0 Flow rate (AS 37.): 0 DN DN 0 DN 0 l/min 30 l/min 0 l/min @ 00 kpa 60 l/min 0 l/min 30 l/min @ 30 kpa 70 l/min 0 l/min 40 l/min @ 00 kpa 7 l/min l/min 4 l/min @ 600 kpa 0 A Flow rate (l/min) (m 3/h) p (kpa) 0 0 00 90 80 70 60 3/4 p (m w.g.) 0 9 8 7 6 4 0 3 40 30 0 E 0, 0, 0 0 0 Flow rate (l/min) (m 3/h) Prod. code Ref. code Set (kpa) DN A B 904093 33H TMS 00 0 3/4 67 C D E Mass (kg) 46 Ø 46 43 0,49 Flow rate (AS 37.): DN 0 30 l/min @ 00 kpa Installation The pressure reducing must be installed by a licensed plumber and in accordance with AS/NZS 300, relevant local requirements and following these instructions. Installation diagram Check Pressure reducing Line strainer (where fitted) Isolating MAINS SUPPLY

Pressure reducing Line strainer (where fitted) Isolating MAINS SUPPLY Check System without recirculation STORAGE HOT WATER HEATER Tempering COLD WATER INLET. Flush the system.. Install the pressure reducing in any position either vertically or horizontally, not upside down, paying attention to the direction of flow indicator on the body of the. 3. Tomson PRV series pressure reducing s are factory set at 30 kpa or 00 kpa. 4. If required, reset the pressure by turning the screw on the top of the plastic cover. Turn it clockwise to increase the pressure and anticlockwise to decrease it. Note: Right-angle has fixed setting, not adjustable. 3

Recommendation for installation conditions Cavitation diagram Upstream pressure (kpa) 000 600 00 800 400 Cavitation high risk Normal working conditions Out of working conditions 00 00 400 600 800 000 00 Downstream set pressure (kpa) To minimize the risk of cavitation within the that may result in malfunctioning with erosion of sealing area, vibrations and noise, it is highly recommended to refer to the working conditions represented in the above diagram. Due to the numerous factors and variable conditions experienced such as system pressure, water temperature, air presence, flow rate and velocity, which may affect the behavior of the pressure reducing, it is advisable that the pressure ratio between the upstream pressure and the downstream set pressure is kept ideally to a value : and no greater than a value of 3:. (For example, upstream 000 kpa, set pressure 00 kpa, the pressure ratio = 000/00 = :). In these conditions, the possible risk of cavitation and malfunctioning is minimised, however this does not exclude the possible effects of the many other variables within the system under operating conditions. If the pressure ratio exceeds the indicated limit, the system design pressure or use of st stage pressure reducing s shall be reviewed. (For example, st stage reducing pressure from 600 to 800 kpa and then nd stage from 800 to 400 kpa). Pipework upstream and downstream of the pressure reducing shall be supported in accordance with the manufacturer s instructions, AS/NZS 300 along with any other local authority requirements, to avoid the creation and transfer of vibration and/or noise into the installation. The inlet strainer of the pressure reducing shall be periodically checked and cleaned, to minimize any partial or complete blockage which may limit the flow rate from the and/or create noise. 4

System flushing, cleaning and disinfection of the pipework to which the is installed shall be performed by suitably qualified persons in accordance with the system component manufacturer s instructions, AS/NZS 300 along with any other applicable local authority requirements. Exceeding the maximum stated chemical concentrations and/or duration of exposure may negatively impact on the performance of the system and/or components installed such as the pressure reducing. Chemical dosed products must be chemically compatible with materials used for the construction of the pressure reducing, specified in its technical documentation. Installation below ground If installing the Tomson PRV series underground, please ensure that steps are taken to protect the from becoming frozen in frost-prone areas or at risk of being submerged by raising water. Please allow yourself sufficient space to remove the cartridge should maintenance be required. The reading of a gauge for setting purposes may be difficult and an alternate means of checking downstream pressure may be necessary. Water hammering This is one of the main problems which may affect pressure reducing s. It is best to fit special devices to absorb water hammering when fitting pressure reducing s in systems at risk. WARNING: If it is critical to maintain the downstream pressure setting to protect equipment, as a safety measure, we recommend that a pressure, or safety, relief is installed downstream of the pressure reducing. Trouble-shooting. Increased downstream pressure near a water heater This problem is due to the water being heated by the water heater. There is no relief of the pressure because the reducing is correctly closed. The solution is to install an expansion vessel (between the heater and the reducer) to absorb the pressure increase.. The pressure reducing does not maintain its set pressure In most cases this is the result of impurities that deposit on the seat causing leakage with a resulting increase in pressure downstream. The solution is to fit a filter upstream from the reducer and subsequently to maintain and clean the cartridge (see Maintenance). Maintenance The pressure reducing is a device that controls the hydraulic circuit and its functioning needs to be checked at least every months. Proceed as follows for periodic cleaning of the strainer and inspection of the cartridge:

Turn off upstream water supply to the pressure reducing and open an outlet downstream to relief pressure Unscrew (anticlockwise) the setting screw to decompress the spring inside. 3 Unscrew the cover. 4 Extract the cartridge with the aid of pincers to grip the head of the screw. After inspection and cleaning, refit the cartridge or, alternatively, fit a replacement cartridge (cover tightening torque: 0 N m). 6 Reset the (see Installation). 3 4 Safety If the pressure reducing is not installed, commissioned and maintained properly in accordance with the instructions contained in this manual, it may not operate correctly, and may cause damage to objects and/or persons. Make sure that all the connections are water-tight. When installing the pressure reducing, make sure not to over-tighten the connections to the as, over time, a failure can occur with subsequent water leakage causing damage. Water temperatures higher than 0 C may cause severe burns. When installing, commissioning and maintaining the device, take the necessary precautions so that these temperatures will not endanger people. In the case of highly aggressive water, arrangements must be made to treat the water before it enters the pressure reducing, in accordance with current legislation. Otherwise, the pressure reducing may be damaged and not function correctly. Leave this operating manual with the user DISTRIBUTOR FOR AUSTRALIA: Reece Australia Ltd 8 Burwood Highway Burwood Victoria 3 Australia Tel. 6 3 974 0000 Fax 6 3 974 03 www.reece.com.au