ALICE SPD cooling system

Similar documents
HANDBOOK SAFETY DEVICES. Ed SAFETY DEVICES DS-ED 01/ ENG 1

Enter your parameter set number (1-27)

The Discussion of this exercise covers the following points:

Visual Observation of Nucleate Boiling and Sliding Phenomena of Boiling Bubbles on a Horizontal Tube Heater

SELECTION CRITERIA FOR SAFETY VALVE

ANALYSIS OF HEAT TRANSFER THROUGH EXTERNAL FINS USING CFD TOOL

Gas Vapor Injection on Refrigerant Cycle Using Piston Technology

A Numerical Study of the Performance of a Heat Exchanger for a Miniature Joule-Thomson Refrigerator

Instruction Manual. Pipe Friction Training Panel

The Discussion of this exercise covers the following points: Pumps Basic operation of a liquid pump Types of liquid pumps The centrifugal pump.

Micro Channel Recuperator for a Reverse Brayton Cycle Cryocooler

1.2 Example 1: A simple hydraulic system

Exercise 4-2. Centrifugal Pumps EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Pumps

MATHEMATICAL MODELING OF PERFORMANCE OF A LIQUD PISTON COMPRESSOR

EDEXCEL NATIONALS UNIT 6 MECHANICAL PRINCIPLES and APPLICATIONS. ASSIGNMENT No. 4

CFD Flow Analysis of a Refrigerant inside Adiabatic Capillary Tube

Vibration-Free Joule-Thomson Cryocoolers for Distributed Microcooling

Practical Guide. By Steven T. Taylor, P.E., Member ASHRAE

Transient Analyses In Relief Systems

Energy and mass transfer in gas-liquid reactors.

LOW PRESSURE EFFUSION OF GASES revised by Igor Bolotin 03/05/12

ENGINEERING FLUID MECHANICS

Applied Fluid Mechanics

Pressure and/or Temperature Pilot Operated Steam Regulators Series 2000

International Journal of Technical Research and Applications e-issn: , Volume 4, Issue 3 (May-June, 2016), PP.

Application Worksheet

This portion of the piping tutorial covers control valve sizing, control valves, and the use of nodes.

THE WAY THE VENTURI AND ORIFICES WORK

Improvement of the Volumetric and Isentropic Efficiency Due to Modifications of the Suction Chamber

Capacity and pressure similar to R-507. Flooded systems. Low temperature (-46.7 C). R22 replacement as long as the condenser has the right size.

The water supply for a hydroelectric plant is a reservoir with a large surface area. An outlet pipe takes the water to a turbine.

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

Vortex Flow Meter Wafer or Flange Connection. - Steam - Liquid - Gas

Earlier Lecture. In the earlier lecture, we have seen Kapitza & Heylandt systems which are the modifications of the Claude System.

Technology issues regarding Blends of Refrigerants Buffalo Research Laboratory

Series Environmental Chambers

MONROE BROTHERS LTD Customer Sigmaphi Project JLab Dipole Safety Relief MB / Description Chimney Vent Capacity & Pressure Drop 301 Issue 1

Effect of Coiled Capillary Tube Pitch on Vapour Compression Refrigeration System Performance

Single Phase Pressure Drop and Flow Distribution in Brazed Plate Heat Exchangers

Modulating Valves for Atmospheric, Infrared, and Direct Fired Burners

A Depletion Compensated Wet Bath Simulator For Calibrating Evidential Breath Alcohol Analyzers

ASSIGNMENT 2 CHE 3473

Capacities Valve Station, type ICF 15, 20, 25

Procedure of Xenon Transfer

Using the CONVAL software for the petrochemical plant control valves checking. Case study

Schedule of Requirements THERMODYNAMICS LABORATORY- CHEMICAL ENGINEERING DEPARTMENT

Unit 24: Applications of Pneumatics and Hydraulics

SUMMARY OF THE EXPERIMENTAL STUDIES OF COLD HELIUM PROPAGATION ALONG A SCALE MODEL OF THE LHC TUNNEL

SOME TECHNICAL AND PRACTICAL RECOMMENDATIONS ABOUT PULSATION DAMPENERS IN CIRCUITS WITH DOSING OR VOLUMETRIC PUMPS

Bioreactor System ERT 314. Sidang /2011

Takayuki Ieki. Introduction. Feature Article

Radiator thermostats type RA2000, valve bodies type RA-FN (series D) and RA-G

Gerald D. Anderson. Education Technical Specialist

INSTRUMENTS A THERMAL MASS FLOW SENSOR USING A CONSTANT DIFFERENTIAL TEMPERATURE ABOVE THE AMBIENT GAS TEMPERATURE

Sign up to receive ATOTW weekly -

(Refer Slide Time: 2:16)

Integral type Differential pressure flowmeter VNT Series

Radiator thermostats type RA2000, valve bodies type RA-FN (series D) and RA-G

HW-1: Due by 5:00 pm EDT on Wednesday 13 June 2018 to GradeScope.

MET Lecture 8 Atmospheric Stability

SOLAR 93 THE 1993 AMERICAN SOLAR ENERGY SOCIETY ANNUAL CONFERENCE. Washington, DC April 22028,1993. Editors: S. M. Burley M. E.

CYCLE ANALYSIS OF LINEAR COMPRESSORS USING THREE- DIMENSIONAL CFD

DISTILLATION POINTS TO REMEMBER

IMPROVED XENON LOADING EQUIPMENT WITH LOADING CAPACITY UP TO 1200 KG FOR ALPHABUS

Heat Pump Connections and Interior Piping

PURE SUBSTANCE. Nitrogen and gaseous air are pure substances.

Numerical prediction and experimental verification of cavitation of Globe type Control Valves

Increase in Evaporation Caused by Running Spa Jets swhim.com

STAD Series. Balancing and control valves. Technical Data Sheet. WattsIndustries.com

Meteorology. Circle the letter that corresponds to the correct answer

Normal Cryogenic Fluid Behavior (emphasis on helium, but not superfluid, which will be covered later) Tom Peterson, SLAC January 2017

Sizing Pulsation Dampeners Is Critical to Effectiveness

EXAM # 2. First Name Last Name CIRCLE YOUR LECTURE BELOW: INSTRUCTIONS

and its weight (in newtons) when located on a planet with an acceleration of gravity equal to 4.0 ft/s 2.

Figure 1 The LHC cryogenic islands and plants layout

SPECIFYING MOTIONLESS MIXERS

AIR EJECTOR WITH A DIFFUSER THAT INCLUDES BOUNDARY LAYER SUCTION

The Air-Sea Interaction. Masanori Konda Kyoto University

ASSIGNMENT 2 CHE 3473

Overview of Earlier Lecture

AIRFLOW GENERATION IN A TUNNEL USING A SACCARDO VENTILATION SYSTEM AGAINST THE BUOYANCY EFFECT PRODUCED BY A FIRE

EDUCTOR. principle of operation

CORESTA RECOMMENDED METHOD N 6

An Investigation of Liquid Injection in Refrigeration Screw Compressors

Gianluca Gemme LN2 DISTRIBUTION PLANT

Figure 1 Schematic of opposing air bearing concept

Study on the Influencing Factors of Gas Mixing Length in Nitrogen Displacement of Gas Pipeline Kun Huang 1,a Yan Xian 2,b Kunrong Shen 3,c

Barcol-Air BRM Radiant Module

EXPERIENCE WITH A PRE-SERIES SUPERFLUID HELIUM TEST BENCH FOR LHC MAGNETS

1 PIPESYS Application

Numerical Simulations of a Train of Air Bubbles Rising Through Stagnant Water

An innovative technology for Coriolis metering under entrained gas conditions

Chapter 13 Fluids. Copyright 2009 Pearson Education, Inc.

Experiment 8: Minor Losses

Performance Testing of a High Capacity Compressor for a 20K 20W Cryocooler

Another convenient term is gauge pressure, which is a pressure measured above barometric pressure.

A virtual EXV mass flow sensor for applications with two-phase flow inlet conditions

XCFD4NRS. Experiments and CFD Codes Application to Nuclear Reactor Safety. OECD/NEA & International Atomic Energy Agency (IAEA) Workshop

AMS 2710 PCB pressure sensor module with V output

This test shall be carried out on all vehicles equipped with open type traction batteries.

Transcription:

ALICE SPD cooling system Requirements: To remove a nominal power of 1380 W distributed per 60 staves (cooling channels) at a nominal duct temperature of C 1 To ensure as much as possible a temperature uniformity along the stave (even if for the time being this requirement has not yet been formulated). To work at reasonable pressure (near atmospheric pressure) in order to reduce the material budget as much as possible To be as much as possible unlikely to leak To be adjustable in real-time, allowing the tuning of the cooling temperature and power removed for each individual stave 1 The overall heat transfer coefficient between the duct inner wall and the chips is unknown at this stage. To begin with, an evaporating temperature of C will be envisaged, believing that the chips' temperature will then stabilize between 0 C and 5 C. In any case, as it will be seen later, the system is flexible enough to vary the evaporation temperature over a reasonable range, in case C turns out to be too high/low. CERN/ST/CV/Cooling of Detectors & Electronics 1

Description of the operating principle 3 Capillary Back Pressure Regulator Stave Pressure Regulator 1 5B 5A Condenser Chilled water 4A circulator 4B Fig 1: Conceptual circuit and Thermodynamic cycle in P-h diagram (qualitative) CERN/ST/CV/Cooling of Detectors & Electronics

The coolant enters the staves as saturated or slightly evaporated liquid (state 1). Evaporation takes place along the stave and the mass flow should be such that nearly saturated vapor (χ 95%?) should leave the staves (state ). If necessary an electrical heater can ensure that the eventual remaining liquid evaporates before exiting the SPD volume. The pressure in the staves is set by the back pressure regulators (). These, as well as the return piping, inevitably introduce a small head loss so the vapor reaches the condenser at state 3. Yet it should be noticed that the pressure in the staves is determined only by the set point on the back pressure regulators and is not influenced by how much lower the pressure is in the condenser. The pressure in the condenser is determined by the flow and temperature of the chilled water. Obviously this pressure should be sufficiently lower than the pressure in the staves so ensure the return of vapor (state 3). See at: http://www.goreg.com/tech_info/animation/bp3_anim.htm for an animation explaining the operation of a Back Pressure regulator (Dome loaded). Assuming that condensation takes place at 1 C, the corresponding pressure drop 3 for the three candidate coolants is(see P-T saturation curves in appendice): 60mbar C 5 F 1, 30 mbar forc 6 F 14 00 mbar for C 4 F 10 To avoid cavitation, the temperature at the inlet of the pump should be as far below 1 C as possible. ST/CV provides a network of chilled water at 6 C throughout CERN, so with an efficient heat exchange, it should be possible to lower the temperature at state 4A down to 8 C? The line 4A 4B represents the pressure rise given by the pump. The temperature rise (resulting from the thermodynamic inefficiency of the pumping process) is usually small, so, unless point 4A is at the right temperature or heat is transferred along the supply line (4B 5A), the liquid will be delivered to the pressure regulators at a temperature which may not be adequate. This would result to liquid being supplied to the staves too cold to be able to start evaporating at the very beginning of the stave (point 1 located to the left of the saturated liquid curve) or in opposition, wasting latent heat of evaporation by being too much into the two phase region.note that states 5A (inlet of pressure regulators) and 5B (inlet of capilaries) are approximately at the same temperature, i.e. equal or, ideally, slightly above the evaporation temperature, (isothermal lines are pretty much vertical on the subcooled liquid side of the P-h diagram). In this case, the whole liquid supply line would be above the dew point in the cavern, and probably would not exchange heat with the outer volumes of the detector in its routing into the SPD. A capillary represents a fixed pressure drop in which the flow is laminar and thereby proportional to the driving pressure difference applied at its ends (Pressure difference P 5B - P 1 ). The pressure at the capillary outlet ( P 1 ) is set by the back pressure regulators and is the pressure at which evaporation takes place in the staves. On the other hand, pressure regulators introduce an adjustable pressure drop, so one can modify the pressure at the capillary inlet P 5B in order to obtain the desired flow rate. CERN/ST/CV/Cooling of Detectors & Electronics 3

The higher the pressure available upstream of the capillary, the wider the available proportional range of flow through it to accommodate stave heat load variation (e.g. varying numbers of powered silicon modules). Hence, the pressure at the pump outlet should be high enough to allow for this proportional fluid flow tuning process. The pump speed can be regulated with a frequency drive in order to obtain the desired outlet pressure. The lower limit to this flow variation happens when the pressure 5B reaches the saturated liquid pressure Psat. For lower Pressure Regulator outlet pressures, evaporation would take place upstream of the capillary thereby obstructing it with vapor bubbles. Preliminary design parameters An evaporating temperature of ºC shall be assumed in the staves. A dissipation of 3W/stave will be assumed The corresponding vapor pressures for the three coolant candidates are: C 5 F 1 (FC-87 from 3M) Psat@ºC= 577 mbara C 6 F 14 (FC-7 from 3M) Psat@ºC= 189 mbara C 4 F 10 (PF-5030 from 3M) Psat@ºC= 1.9 bara The corresponding latent heat of vaporization is: C 5 F 1, Hfg @ºC =104 618 J/kg C 6 F 14, Hfg @ºC =107 958 J/kg C 4 F 10, Hfg @ºC =91 008 J/kg Mass and volumetric flow needed Density at ºC Kg/m3 Flow / stave 6 staves (one sector) 60 staves Sat Sat g /s L/min g /s L/min g /s L/min liquid vapour in out in out in out C 5 F 1 163.8 7.3 0. 0.01 1.8 1.3 0.05 10.95 13.19 0.49 109.47 C 6 F 14 1747..7 0.1 0.01 4.70 1.8 0.04 8. 1.78 0.44 81.97 C 4 F 10 36 0.75 0.5 0.01 0.73 1.5 0.06 4.38.16 0.59 43.85 Note: this is assuming saturated liquid at the staves inlet and saturated vapor at the outlet, i.e., full advantage is taken of the latent heat (ideal situation). In reality, the flow needed may be up to 1.5 times higher (corresponding to /3 of the max latent heat being used). For selecting the pump, a nominal flow rate of 0.75 L/min and P=5 bar shall be assumed. CERN/ST/CV/Cooling of Detectors & Electronics 4

Estimation of heat transferred at the condenser (for 60 staves) and water flow rate required: Cp (J/Kg. ºC) Liq @ 10 ºC g /s Hfg @1ºC (J/kg) Qcond (W) To subcool to 8ºC (W) Water flow rate required L/min (Tin=6ºC, Tout=10ºC) C 5 F 1 109 13.19 105 607 1393 54 5. C 6 F 14 109 1.78 108 875 1391 5 5. C 4 F 10 1056.16 9 079 1396 64 5. For 6 staves (one sector): Qcond (W) To subcool to 8ºC (W) Water flow rate required L/min (Tin=6ºC, Tout=10ºC) C 5 F 1 139 5 0.5 C 6 F 14 139 5 0.5 C 4 F 10 139 6 0.5 SYSTEM CONTROL Similarly to other LHC experiments, in the final installation pressure regulators are likely to be located in the experimental cavern, where the magnetic field might be beyond the acceptable limit for standard industrial control electronics. This will require the use of analog air pressure-piloted regulators driven by remote electro-pneumatic converters. To ensure that the correct flow rate is being sent into each stave, the pressure regulators will be individually tuned via feedback control according to the circuit load variation. A temperature sensor on the exhaust tubing sends a feedback signal to a commercial PID controller (model G9FTE-R*E1R-88-N Mfr: RKC Instruments). The PID controller sends an analog signal to an electro-pneumatic converter, which in turns sends an analog pressure signal to a (several) pressure regulators. Alternatively, PID control can be implemented using a BridgeView PID extension toolkit, with WAGO DAC modules to pilot the electro-pneumatic converters. A hard-wired thermal interlock system triggered by negative temperature coefficient sensors (NTC) automatically cuts power to individual silicon modules should their temperature exceed safe values (in case of coolant flow or de-lamination of a particular module from its cooling channel, etc) Pressure at the pump outlet (state 5A) can be regulated via PID variation of the pump speed. CERN/ST/CV/Cooling of Detectors & Electronics 5

Which liquid to choose? The ideal would be to evaporate at a pressure below atmospheric in order to avoid leaks, yet not too low so that thinner cooling ducts can be used. On the other hand, the pressure drop in the return line must be lesser or equal to the difference between evaporation and condensation pressure (if it is lesser, additional head losses can be added). An estimation will be made for the pressure drop endured by the coolant from the moment it enters the stave as saturated liquid at C to the reservoir where condensation takes place. a) estimation of pressure loss in one stave Relevant Properties for head losses calculation: Density at ºC Kg/m3 Sat liquid Sat vapour Kinematic viscosity Sat liquid m /s Sat vapour C 5 F 1 163.8 7.3 3 x10-7 5 x 10-7 C 6 F 14 1747..7 4.37x10-7 5 x 10-7 C 4 F 10 36 0.75 1.6x10-7 5 x 10-7 The equivalent hydraulic diameter for the cooling ducts is 0.6 (.8 0.6) 0.6 + π D Area 1.607 = 4. = 4. 4 = 4. = 1. mm H wettedperimeter (.8 0.6) + π 0.6 6.85 0 Theoretical estimation of frictional pressure drop for two-phase flow is not only complex but also of uncertain accuracy so it will not be attempted here. Instead, estimations were made for two hypothetical cases: (i) assuming 100% of the mass flow as liquid all along the stave and (ii) 100% of the mass flow as vapor all along the stave. As can be seen below, due to the fact that pressure losses depend loosely from the square of the velocity, the flow would be laminar in case (i) and turbulent in case (ii). Since the staves are of reduced length (L=88 mm) the approximation adopted will be to take the average between (i) and (ii). CERN/ST/CV/Cooling of Detectors & Electronics 6

Reynolds - if only liquid- Reynolds - if only vapor- pressure loss - if only liquid- (mbar) pressure loss - if only vapor- (mbar) Average (liq+vap)/ (mbar) Corresponding T glide along the stave C C 5 F 1 87 (laminar) 38731 (turb.) 3.7 81.8 4.7 C 6 F 14 175 (laminar) 9871 (turb.) 5.1 164.5 84.8 1 C 4 F 10 639 (laminar) 335 (turb.).3 44.3 3.3 0.5 Note : Pressure losses were calculated with: P = 64 Re 1 V P = 0.184Re L D 0. ρ 1 V Laminar flow L D ρ Turbulent flow b) Pressure loss estimation for one vapor return line (segment within the detector) The diameter within the detector has to be reduced to the bare minimum, so three values were considered: 10, 1 and mm. The length of the pipe is not known yet, nor is the number of elbows. For one elbow, the equivalent length in pipe diameters can be assumed as 0 40. This means that, for instance, it would take 10 elbows to introduce an additional equivalent length of 1 m in linear losses for a 10mm pipe. Pressure losses in mbar Inner Diameter 10 mm ID 1 mm ID 14 mm ID Equivalent length 1m 5m 1 m 5m 1m 5 m C 5 F 1 6.4 660 11 75 5.3 131. C 6 F 14 54.5 1363 3 568 10.8 71 C 4 F 10 14.6 365 6.9 7.5 c) Pressure loss estimation for vapor return line outside the detector Once the pipe exits the detector, the diameter can be enlarged to reduce pressure losses to negligible values (note that pressure losses are loosely proportional to 1/ 4.8 for turbulent regime). Each group of N individual lines will then converge into a collector which in its turn leads to a back pressure regulator. Finally, all the 60/N back pressure regulator's outlets will converge to a single line returning to the condenser. CERN/ST/CV/Cooling of Detectors & Electronics 7

Why evaporate? 6 reasons: 1. To enhance the heat transfer The heat transfer coefficient changes progressively as the refrigerant evaporates along the tube. The vapor fraction increases and the agitation thereby caused enhances the heat transfer coefficient. When the refrigerant is nearly all vaporized, the coefficient drops off to the magnitude applicable to vapor transfering heat by forced convection. Fig 1 shows very clearly that the heat transfer coefficient increases significantly from liquid convection (left of the curve) to liquid boiling (peak of the curve) V. Vacek and Greg Hallewell measured coefficients in the order of 000 to 5000 W/m K for similar perfluorocarbons evaporating along a 3.6mm ID capillary. CERN/ST/CV/Cooling of Detectors & Electronics 8

. To reduce the temperature increase along the stave The heat transferred to the liquid is used for phase change and not to increase its temperature, so the temperature increase along the stave is very small. Temperature uniformity is a common requirement for HEP detector cooling 3. To reduce the circulating coolant mass The latent heat of evaporation is much higher than the sensible heat. example: for C3F8 at -30 C latent heat = 104 kj/kg sensible heat = 1 kj/kg per K of liquid temperature increase so 1 kw can be removed at -30 C by evaporating 9.6 g/s of liquid C3F8 or by increasing 1 K the temperature of a 1000 g/s flow of liquid C3F8 4. To reduce pipe dimensions (lower material budget) Smaller flow rates smaller pipe diameter. Smaller flow rates smaller pressure drops thinner pipes may be used. 5. Possibility to have parallel channels at different temperatures By evaporating at different pressures (ex. by means back pressure regulators). Such control is impossible in a parallel liquid cooling system with a single liquid supply temperature ) 6. Little pipe insulation required Insulation is only needed downstream of the expansion device, which usually is very close to the detector. CERN/ST/CV/Cooling of Detectors & Electronics 9

Price estimation a)test Unit aims: To determine an overall heat-transfer coefficient for the cooling duct-chips. To determine the ideal evaporation temperature to obtain 0 C on the chip surface. To determine the pressure loss along the cooling ducts To compare two configurations of access to SPD barrel Config 1: service the SPD barrel from one side 5 3 7 8 7 6 4 5 1 0 1 3 13 1 14 CERN/ST/CV/Cooling of Detectors & Electronics 10

Config : service the SPD barrel from both sides 5 7 8 7 3 6 4 5 1 0 1 3 13 1 14 CERN/ST/CV/Cooling of Detectors & Electronics 11