H&D Fitzgerald Pressure Pyknometry System Mark 5

Similar documents
Micro Motion 7812 Fiscal Gas Density Meter

DENSITY CALIBRATIONS AT MIKES. Heikki Kajastie, Jorma Manninen and Kari Riski Centre for Metrology and Accreditation (MIKES) ABSTRACT

Volume Determination for 2 kg~20 kg in NIM

Compiled by: B Beard. Approved by: SH Carstens. Description of requirements and procedures for compact provers to be used as verification standards.

Test pumps. Pressure sources. Good reasons for proper and reliable calibration

CRYOGENIC PRESSURE REGULATOR

AUTOMATIC HOSE TEST UNIT, TYPE SPU

Oxygen Measurement Systems High Reliability and Wide Application Coverage

Operating Manual ALU 7 - ALU 10 - ALU 20 - ALU 26 ALU 35 - ALU 60 - ALU 100

ONSITE PROVING OF GAS METERS. Daniel J. Rudroff WFMS Inc West Bellfort Sugar Land, Texas. Introduction

JOS 15 JOS 25 JOS 40. Manual and semiautomatic test benches from DN 25 to DN 40. Characteristics. Basic characteristics. Test bench using balances

Brooks Flow Controllers for Gas and Liquid Service Model FC 8744, Series FC 8800 and FC 8900

TRZ 03-K Volumeter. Proven Technology. Superior Performance. TRZ 03-K Volumeter is a Turbine Gas Flowmeter for Secondary Gas Metering.

ADVANTAGES DESCRIPTION MECHANICAL FITTINGS AND DIMENSIONS

TESTING BENCHES for watermeters

Flexible Metal Hose Products

Hydraulic pressure balance Model CPB5800

Micro Motion 7835 Series Density and Concentration Meters

Unique mounting features for Thermal Mass Flow Meters. By Martin Raab in cooperation with CaTeC b.v.

FPG8601 Force Balanced Piston Gauge

ALU-CD 12, ALU-CD 25, ALU-CD 35, ALU-CD

THE NATURAL CHOICE. High end valves for the natural gas value chain. Inspired By Challenge

800 Series Mass Flow Meters and Controllers. High Performance Mass Flow Meters and Controllers

CHAPTER 6 MEASUREMENT OF INSPECTION PARAMETERS. Measurement Ports

Technical Datasheet ZHA Series Gear Flow Meters Aluminum Version with ball bearing for lubricating media

Electro-Magnetic Flowmeters Electromagnetic Sensor

P3000 Series. Pneumatic Deadweight Testers Model P3000. Technical Data. Features

Validation of Custody Transfer Metering Skid at Site After Laboratory Proving

P3000 Series. Pneumatic Deadweight Testers Model P3000. Technical Data. Features

TEK-SUB 4800B. Submersible Level Transmitter. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys LEVEL

Hydraulic hand test pump Models CPP700-H and CPP1000-H

GFM. Typical Aluminum GFM Mass Flow Meter NIST MASS FLOW METERS. Principles of Operation. Design Features

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER TRANSPORTABLE CRUDE OIL CONTAINER

Improve Process Reliability

ASME and PED Requirements for Drum Level Instrumentation. Presented by: Amir Hedayatnia Clark-Reliance Corp.

Impact of imperfect sealing on the flow measurement of natural gas by orifice plates

Peak Pressure Indicator MSI-3

Coriolis Mass Flow Meter

HUMOR 20. High Accuracy Humidity Calibrator. Water T, p1 HUMOR 20 V1.0

Multiphase MixMeter. MixMeter specification. System Specification. Introduction

Tensiometer For the measurement of surface and interfacial tension

Instrumentation Catalogue

PP-1, PP-1W, PP-2, & PP-3

Self-operated Pressure Regulators for special applications

CHE Well Testing Package/Service:

Aging Cell, OFITE Style. Included Items

Pressure is our Business

Elcometer Viscosity Cup. Operating Instructions

Micro Motion 3098 Gas Specific Gravity Meter

Integral type Differential pressure flowmeter VNT Series

Automatic Isokinetic Sampler. ST5 Evo

Vaisala Pressure, RH & Temp. Transmitter. The instrument was operational upon receipt. The instrument was adjusted and calibrated.

TECHNOLOGIES. M Series. Positive return metering pumps [API675]

Guide No. 2/2009. Design, training and equipment Martin Firlus. Physikalisch Technische Bundesanstalt Braunschweig und Berlin

NEW VERSAFLOW CORIOLIS

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER RELIEF VALVE

CHECK VALVES FOR CRYOGENIC SERVICE

Instrumentation & Data Acquisition Systems

White Paper August , Rev AA

Additel 761 Automated Pressure Calibrators Selection Guide

Additel 761 Automated Pressure Calibrators

GMC-I Service GmbH Calibration Center

Thermo Probe, Inc. TP-5 TP-7 TP-8. Instruction Manual English. Switch. Display. Carry Strap. Probe. Ground Clip. Switch. Display.

CRYOGENIC TANK SERVICES - CHART RECORDER MANUAL

Density2Go. Hydrometers Pycnometers Digital Hydrometers. 3 Ways to Measure Density Know-How, Hints, and More

PHIL JANOSI MSC. International Product Manager, Coriolis Flowmeter KROHNE Ltd, UK.

Product information. Capacitive. Level detection in liquid VEGACAP 62 VEGACAP 63 VEGACAP 64 VEGACAP 66 VEGACAP 69. Document ID: 29983

HUMOR 20 HUMOR 20. High-precision Humidity Calibrator. Water T, p1

Description Advanced Features Typical Applications

UKAS calibration laboratory 8809 Temperature, pressure and electrical signals calibration guide

ZHM ST Series. Technical Datasheet. Gear Flow Meters for lubricating, non lubricating, abrasive and corrosive fluids

Brooks Flow Controllers for Gas and Liquid Service Model FC 8744, Series FC 8800 and 8900

130400A 1/2 NPT Female A 3/4 NPT Female A 1 NPT Female A 1 1/4 NPT Female A 1 1/2 NPT Female A 2 NPT Female

High-speed pressure sensor Model CPT6140

Tensiometer For the measurement of surface and interfacial tension

Beamex. Calibration White Paper. Weighing scale calibration - How to calibrate weighing instruments

Additel 761 Automated Pressure Calibrators Selection Guide

HUMOR 20. High-precision Humidity Calibrator HUMOR 20. Operation

Sartorius CCL kg Prototype Mass Comparator

Precision pressure sensor Basic version Model CPT6020

Brooks TMF-Zone 1 Models 5816-Ex/5864-Ex

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS

Pressure Automated Calibration Equipment

PMI Advanced Automated. Pulse Decay Permeameter APDP-10K-HP-101. Not just products... Solutions!

Albany Connecticut Vermont Westchester

ABB MEASUREMENT & ANALYTICS DATA SHEET. AP100 ph/redox (ORP) cartridge sensors with water-wash option

Technical Data Sheet. OPTIMASS 7000 Custody Transfer Mass Flowmeter

SPECIFICATION // DATA SHEET WATER DRAIN VALVE AM SENSORS LTD AMS-S-084/DS/ (ISSUE 1)

SV5 Safety Valve Installation and Maintenance Instructions

tel: fax: web:

Hand-held pressure calibrator with integrated pump Model CPH6600

DIGITAL AUTOMATIC TYRE INFLATOR

FPD175 Compact orifice carrier assembly

ASEPTIC SAMPLING VALVES SANITARY SAMPLING VALVES SANITARY SAMPLING BOTTLE TANK BOTTOM ASEPTIC VALVE

abc INSTALLATION, OPERATING & MAINTENANCE MANUAL FOR HYDRAULIC EXTRACTOR

T EK-SUB 4800C 19 mm Submersible Level Transmitter

Operational experiences with the EuroLoop Liquid Hydrocarbon Flow Facility

Specific Accreditation Criteria Calibration ISO IEC Annex. Mass and related quantities

CERTIFICATE on measurement instruments type approval

SF 6 Product Guide. Gas Analysis Instruments and Accessories

Transcription:

Setting the standard in density H&D Fitzgerald Pressure Pyknometry System Mark 5 Simple Portable Traceable Remember! Your density meter is only as good as its last calibration! A fundamental calibration method for hydrocarbon density meters Fully compliant with iso 9857, api Chapter 9.4, and gost 8.024, mi 2816

Pressure Pyknometry The H&D Pyknometer The H&D Pressure Pyknometry System Mark 5 (pps5) is designed to allow pyknometry measurements in a laboratory or on site to mi 2816 The standard system is suitable for sampling oils with densities from 700 to 1600 kg/m³, at pressures up to 6.5 MPa and liquid temperatures from 3 C to 50 C. We can also supply systems meeting pressure ranges up to 10 MPa, and temperature ranges up to 90 C. The pps5 has type approval certificate 30919, registed in the State Register of Measuring Instruments under 37320-08, and is manufactured under our iso 9001 accreditation. A pyknometer is a stainless steel pressure vessel which is used to calibrate and validate density meters for oil and oil products. Pyknometry gives direct verification of the density meter s reading, and so enables very accurate calibration of the instrument in-situ. Unlike secondary techniques, such as transfer densitometers, pyknometry is a fundamental calibration method which allows traceable calibration of online density meters at their on-line conditions. Features: 11.5 mm diameter valve ports to enable high flow rates through the vessel, and give rapid temperature stabilisation. Internal shape designed to give good mixing with no low-velocity zones. This mitigates against the collection of gas bubbles or water droplets. Simple, low-maintenance valves, and integral clip-on connectors. A working pressure of up to 100 bar, with test certificates from dnv (similar to Lloyds and Rostechnadzor). The vessel is also fitted with a rupture disc to guard against the build up of excess pressure. Built under European ped approval from dnv. The H&D pressure pyknometer, through its unique design, ensures accurate measurements, and is simple to use. Measurement you can trust

H&D Fitzgerald Pressure Pyknometry System Mark 5 A fundamental calibration method for oil and oil products density meters A fully portable calibration system Pyknometry is the most reliable way of calibrating density meters. It is the only calibration method which overcomes possible measurement errors such as liquid viscosity, flow rate, temperature, mounting torque, pressure, position and vibration. H&D Fitzgerald s Pressure Pyknometry System Mark 5 (pps5) provides a foolproof way of calibrating crude oil density meters in-situ, and is fully compliant with iso 9857 and api Chapter 9.4. This measurement system is capable of determining density to better than 0.1 kg/m 3 at the 95% confidence level. All aspects of the pps5 are calibrated traceably to recognised national standards. A full set of calibration certificates is provided. The pps5 is fully portable, for easy transport by air. All the equipment that you need is fitted into five toughened polypropylene cases. Main System Case Balance Case Weights Case Hoses Case Pyknometer Carry Case Total: 21 kg 10 kg 7 kg 20 kg 13 kg 71 kg All cases are water resistant, dustproof, and crushproof, and can be locked for security. Setting the standard in density

A Comprehensive Calibration System Main System Case The main system case is connected to the plant during sampling. It contains all the equipment necessary to collect a representative sample of oil at the same temperature and pressure as that flowing through the density meter. Features: Two Wika cpt6210 pressure sensors with digital displays. These units have a resolution of 0.01 bar and are intrinsically safe. Two Elemer тцм 9410-м1-н dual-input compact digital thermometers. One unit connects to two contact sensors in protective shoes which measure the temperature of the oil sample in the pyknometers. The other connects to two temperature probes which measure the temperature of the oil in the pipeline. Again, the units are intrinsically safe. A valve plate with flow indicator and self-sealing Dry Break stems for connecting the hoses from the plant to the pyknometers. An insulated pyknometer box. This is mounted in an upright position during sampling. An integrated toolbox containing various tools required when operating and servicing the system, and sufficient spare parts for three years operation. Pyknometer Carry Case The pyknometer carry case ensures the safe storage and transport of the calibrated pyknometers when not in use. Measurement you can trust

All instruments and weights supplied by H&D Fitzgerald are calibrated traceably to national standards. Hose Case The hose case contains all the necessary hoses and connectors to connect the system to the plant. All hoses have smooth ptfe liners, stainless steel braid for safety, a layer of insulating foam rubber, oil-resistant Viton sheaths, and are designed to guard against the build up of static electricity. The hoses are also equipped with Dry Break connectors which are oil and gas leak free when disconnected. An adaptor is provided to allow the hoses to be emptied and cleaned prior to transport. Balance Case The system is supplied with a Mettler Toledo xs6002s Precision Balance. This is used to weigh the pyknometers. The balance has a working range of up to 6.1 kg, with a readability of 10 mg. Weights Case The system comes complete with four stainless steel oiml Class e2 weights (2 2 kg and 2 1 kg) which are used to calibrate the balance. These precision weights are engraved for identification, and have ultra low magnetic field strength and permeability. Setting the standard in density

Traceability Giving you confidence in your measurements All instruments and weights supplied as part of the Pressure Pyknometry System Mark 5 are calibrated traceably to recognised national standards held by the UK National Physical Laboratory and other National Measurement Institutes. Each system comes with a quality manual containing calibration certificates, test certificates, and a comprehensive operators manual. All documentation is provided in Russian. Measurement you can trust

Procedure Couldn t be easier! Pyknometry is a simple and foolproof calibration method. Two empty and clean pyknometers are weighed and connected in series to the flowing oil directly downstream of the density meter to be calibrated. The pyknometers are then filled with a representative sample of oil at the same temperature and pressure as the oil flowing through the density meter. The system measures the pressure immediately upstream and downstream of the pyknometers so that the average value gives the pyknometer pressure. Once the pyknometers have stabilised at the oil temperature, the valves are closed. The pyknometers are then are removed from the pipeline, the outsides are cleaned, and they are reweighed. The oil density at density meter conditions is then calculated from the mass of oil in the pyknometers, the volume of the pyknometers at the measured temperature and pressure, and the air density. An independent density is calculated for each pyknometer. The two independent results can then be checked against each other, as per the gost requirements. The illustrated operators manual describes this process in detailed, easy-to-follow steps. Pyknometry measurements made in this way ensure compliance with iso 9857, api Chapter 9.4, and gost 8.024 and mi 2816. Setting the standard in density

Designed, built, and calibrated by: H&D Fitzgerald Ltd Cefn Du Tremeirchion St. Asaph LL17 0US UK Tel: +44 1352 720774 sales@density.co.uk www.density.co.uk Sold by: IMS Vavilova Street, Building 47a 117312, Moscow Russian Federation Tel.: +7 (495) 775-77-25 Fax: +7 (495) 221-10-51 ims@imsholding.ru www.imsholding.ru H&D Fitzgerald is recognised as a world authority on density metrology. For more information about our other products and services please visit www.density.co.uk Setting the standard in density