Notice of Intent to Close Inactive CCR Surface Impoundments

Similar documents
Coal Combustion Residuals Closure Plan

CLOSURE PLAN. CFR (b) GERS Bottom Ash Pond. Northeastern 3&4 Power Station Oologah, Oklahoma. October, 2016

CLOSURE PLAN. CFR (b) Bottom Ash Pond Complex Cardinal Plant Brilliant, Ohio. September, 2016

CLOSURE PLAN. CFR (b) Document ID: GERS Bottom Ash Complex. Mountaineer Plant New Haven, West Virginia.

CLOSURE PLAN. CCR (b) GERS East and West Bottom Ash Ponds. Pirkey Power Plant Hallsville, Texas. October, 2016

Written Closure Plan. Pawnee Station - North CCR Landfill Public Service Company of Colorado Denver Colorado. October 17, 2016

TABLE OF CONTENTS LEGAL NOTICE

TABLE OF CONTENTS 1.0 INTRODUCTION PLAN CERTIFICATION (B)(4) 1

D.B. Wilson Station CCR Landfill

2018 Annual Inspection Report

2016 Annual Inspection Report

CLOSURE PLAN. CCR (b) GERS Landfill Area. Welsh Power Plant Pittsburg, Texas. October, 2016

CCR Landfill 2017 Annual Inspection Report NC1 Ash Disposal Area

TABLE OF CONTENTS LEGAL NOTICE

TABLE OF CONTENTS LEGAL NOTICE

Written Closure Plan. Pawnee Station - Active CCR Landfill Public Service Company of Colorado Denver Colorado. October 17, 2016

Written Closure Plan. Comanche Station - Active CCR Surface Impoundment Public Service Company of Colorado Denver, Colorado

Written Closure Plan. Cherokee Station - Active CCR Impoundments Public Service Company of Colorado Denver, Colorado.

2017 Annual Inspection Report

CCR Closure Plan. CCR Certification: Written Closure Plan (b) & (c) for the. Landfill Sedimentation Pond. A. B. Brown Generating Station

Closure Plan for CCR Surface Impoundments

Mr. Michael Malone CPS Energy 145 Navarro Street, Mail Drop San Antonio, Texas Project No

CHOLLA POWER PLANT CLOSURE PLAN (b) SEDIMENTATION POND CH_ClosPlan_004_

FOUR CORNERS POWER PLANT CLOSURE PLAN (b) UPPER RETENTION SUMP FC_ClosPlan_011_

2016 Annual Inspection Report

Hard Hat Services ph: hardhatinc.com 932 N. Wright St., Suite 160 Naperville, IL 60563

STRUCTURAL STABILITY ASSESSMENT

FOUR CORNERS POWER PLANT CLOSURE PLAN (b) COMBINED WASTE TREATMENT POND (CWTP) FC_ClosPlan_012_

Annual CCR Landfill Inspection OML Existing Landfill OML Expansion Phase 1

CCR Unit Closure and Post-Closure Plan. The business of sustainability. Texas Municipal Power Agency Gibbons Creek Steam Electric Station

APPENDIX C VEGETATED EMERGENCY SPILLWAY. VERSION 1.0 March 1, 2011

Whitewater Valley Station Surface Impoundment Coal Combustion Residual Annual Report

CCR Closure Plan Ash Impoundment

CCR Landfill 2018 Annual Inspection Report North Omaha Ash Landfill

Hard Hat Services ph: hardhatinc.com 932 N. Wright St., Suite 160 Naperville, IL 60563

Initial Annual CCR Landfill Inspection OML Existing Landfill OML Expansion Phase 1

CCR Certification: Fugitive Dust Control Plan (b) for the. West Ash Pond. at the. F. B. Culley Generating Station.

LEGAL NOTICE. Report No. SL Revision: 0 Page No. i. Ottumwa Generating Station Notification of Intent to Initiate Closure

CCR Fugitive Dust Control Plan

Amec Foster Wheeler 2016.

CCR Landfill 2015 Annual Inspection Report NC1 Ash Disposal Area

Northern Indiana Public Service Company Michigan City Generating Station Primary Settling Pond Number Annual RCRA CCR Unit Inspection Report

Amended Written Closure Plan

October 16, GRDA CCR Landfill Compliance Report Grand River Dam Energy Center 8142 Hwy 412B PO Box 609 Chouteau, OK Dear Mr.

COAL COMBUSTION RESIDUALS (CCR) FUGITIVE DUST CONTROL PLAN SANDY CREEK ENERGY STATION RIESEL, TEXAS. Prepared for:

ANNUAL INSPECTION BY A QUALIFIED PROFESSIONAL ENGINEER ALL CCR IMPOUNDMENTS CCR Rule Section (b)

FUGITIVE DUST CONTROL PLAN

COAL COMBUSTION RESIDUALS (CCR) FUGITIVE DUST CONTROL PLAN SANDY CREEK ENERGY STATION RIESEL, TEXAS. Prepared for:

CCR CLOSURE PLAN Sibley Slag Settling Impoundment Sibley Generating Station East Johnson Rd Sibley, Missouri

Annual CCR Landfill Inspection. Lansing Landfill. Interstate Power and Light Company. Prepared for:

Sediment Basin 7E-12. Design Manual Chapter 7 - Erosion and Sediment Control 7E - Design Information for ESC Measures BENEFITS.

Chutes Part 2: Synthetic linings

SECTION [ ] [02730] STABILIZED DECOMPOSED GRANITE SURFACING

Green CCR Surface Impoundment

Suitable Applications Check dams may be appropriate in the following situations: To promote sedimentation behind the dam.

ANNUAL INSPECTION BY A QUALIFIED PROFESSIONAL ENGINEER ALL CCR IMPOUNDMENTS CCR Rule Section (b)

As temporary grade control facilities along waterways until final stabilization is established.

COAL COMBUSTION RESIDUAL (CCR) FUGITIVE DUST CONTROL PLAN

Annual Inspection Report of CCR Impoundment and CCR Landfill Wenck Project # B

2016 Annual Landfill Inspection Report. SCE&G Wateree Station Class III Landfill

ITEM 400 STRUCTURAL EXCAVATION AND BACKFILL

(Revised February,2005) CULVERTS, BRIDGES, AND FORDS

Low Gradient Velocity Control Short Term Steep Gradient Channel Lining Medium-Long Term Outlet Control Soil Treatment Permanent [1]

ENGINEER S CERTIFICATION OF AQUIFER SEPARATION DEMONSTRATION (40 CFR )

JAP Additional Information Sheet

FUGITIVE DUST CONTROL PLAN

Bids DECEMBER 21, 2018 AT 2:00 P.M. (EASTERN) (Estimated Cost: $4,700,000.00)

COAL COMBUSTION RESIDUAL (CCR) FUGITIVE DUST CONTROL PLAN

CENGRS GEOTECHNICA PVT. LTD. Job No Sheet No. 1

HISTORY OF CONSTRUCTION

The Spartan Cap Athletic Field System

INFILTRATION PRACTICE MAINTENANCE INSPECTION FORM

Definitions as used in this Subchapter:

Researchers propose a cost effective solution for failing native soil athletic fields across Michigan.

Consulting Engineers and Scientists Annual Landfill Inspection Report. for the. Williams Station Highway 52 Class III Landfill

BIOREACTOR LANDFILLS: GEOTECHNICAL ASPECTS OF STABILITY EVALUATION

Big Rivers Electric Corporation - D.B. Wilson Generating Station. Fugitive Dust Control Plan for Coal Combustion Residuals

Earthen Embankments. turning into larger, more costly repairs. The following. The State Dam Safety Program has inspection

COTTER MILL SITE SUMMARY - RML

Trout Unlimited Comments on the Scope of Environmental Impact Statement for the Constitution Pipeline Project, Docket No. PF12-9

USING A LABYRINTH WEIR TO INCREASE HYDRAULIC CAPACITY. Dustin Mortensen, P.E. 1 Jake Eckersley, P.E. 1

Dry Hydrants. The installation of a non-pressurized pipe system into local water sources provides a ready means of supplying water to fire engines.

Kansas Department of Transportation. Tabulation of Bids

RULES OF THE OIL AND GAS PROGRAM DIVISION OF WATER RESOURCES CHAPTER DRILLING WELLS TABLE OF CONTENTS

New Castle County Guidelines for the Certified Construction Reviewer, Owner/Developer, Site Contractor and Professional Engineer

CHAPTER 4: BEST MANAGEMENT PRACTICES FOR EROSION AND SEDIMENTATION CONTROL

RoaDrain Synthetic Subsurface Drainage Layer (SSDL)

Dredging Engineering Short Course Texas A&M University January 2016

ROAD OCCUPANCY PERMIT APPLICATION # Damascus Township, 60 Conklin Hill Road, Damascus, PA Tel Fax

Bids MAY 24, 2018 AT 2:00 P.M. (EASTERN) (Estimated Cost: $7,500,000.00)

ADA on Construction. Guidance for Section C Plan Preparers

PRELIMINARY STORM DRAINAGE REPORT

Accommodating Pedestrians in the Work Zone

Big Rivers Electric Corporation - Sebree Generating Station (R. A. Reid, R. D. Green and HMPL Station Two)

2018 INSPECTION REPORT

COAL COMBUSTION RESIDUALS FUGITIVE DUST CONTROL PLAN

Design Assessment Checklist: Infiltration / Detention Basin

RIIWMG203D Drain and Dewater Civil Construction Site Learner Guide

Trout Buffer Variance

ADA Training Standard Plans

Transcription:

Notice of Intent to Close Inactive CCR Surface Impoundments Virginia Electric and Power Company Possum Point Power Station Coal Combustion Residual Surface Impoundments A, B, C, D, and E Dumfries, Virginia GAI Project Number: C150132.00 December 2015 Prepared by: GAI Consultants, Inc. Prepared for: Virginia Electric and Power Company Richmond Office 5000 Dominion Boulevard 4198 Cox Road, Suite 114 Glen Allen, Virginia 23060-3308 Glen Allen, Virginia 23060

Notice of Intent to Close Inactive CCR Surface Impoundments Virginia Electric and Power Company Possum Point Power Station Coal Combustion Residual Surface Impoundments A, B, C, D, and E Dumfries, Virginia GAI Project Number: C150132.00 December 2015 Prepared for: Virginia Electric and Power Company 5000 Dominion Boulevard Glen Allen, Virginia 23060-3308 Prepared by: GAI Consultants, Inc. Richmond Office 4198 Cox Road Suite 114 Glen Allen, Virginia 23060

Page i Table of Contents A. B. Introduction... 1 Site Description... 1 C. Closure of Surface Impoundments... 1 C.1 C.2 Surface Impoundments A, B, C, and E Closure Description...1 Surface Impoundment D Closure Description... 1 D. E. Closure Schedule... 3 Professional Engineer s Certification... 4 Table 1 Tab le 2 Surface Impoundments A, B, C, and E Construction Schedule Surface Impoundment D Construction Schedule 2015 GAI Consultants, Inc.

Page 1 A. Introduction Coal Combustion Residual (CCR) Surface Impoundments A, B, C, D, and E are Inactive CCR Surface Impoundments located at the Possum Point Power Station (Station). The Station is owned and operated by Virginia Electric and Power Company, d/b/a Dominion Virginia Power (Dominion). The Surface Impoundments are subject to the United States Environmental Protection Agency s (EPA) final rule for Disposal of CCRs from Electric Utilities in Title 40 Code of Federal Regulations (CFR) Part 257, Subpart D (CCR rule). Dominion intends to initiate closure of these Inactive CCR Surface Impoundments, as defined by the CCR rule, under the requirements of 257.100(b) of the CCR rule. B. Site Description The Station is located near Dumfries in Prince William County, VA. The Station is accessed by Possum Point Road (Route 633) and is adjacent to the Potomac River and Quantico Creek. There are currently five inactive CCR impoundments located at the Station: Surface Impoundments A, B, C, D, and E. The Station stopped using coal as a fuel in 2003 and therefore no CCR has been generated by the Station since that date. C. Closure of Surface Impoundments The Inactive CCR Surface Impoundments A, B, C, D, and E will be closed pursuant to 40 C.F.R. 257.100(b). A description of how the impoundments will be closed is provided below. C.1 Surface Impoundments A, B, C, and E Closure Description Surface Impoundments A, B, C, and E will be closed through the removal of CCR in the impoundments, thus meeting the requirements of 40 CFR 257.100(b)(5). Prior to October 19, 2015, Dominion mechanically dredged CCR from Surface Impoundments A, B, C, and E and placed the dredged CCR in Surface Impoundment D per the requirements of the Station s Virginia Pollutant Discharge Elimination System (VPDES) Permit No. VA0002071. CCR remaining in Surface Impoundments A, B, C, and E after October 19, 2015 will be excavated and properly disposed off-site. Water that comes in contact with CCR during closure activities or is generated by dewatering activities will be discharged in accordance with the Station s VPDES Permit No. VA0002071. After removal of the CCR from the impoundments, a registered professional engineer will visually examine the bottom of Surface Impoundments A, B, C, and E for the purpose of verifying that all CCR in the surface impoundments has been effectively removed per regulatory requirements. All CCR in Surface Impoundments A, B, C, and E will be removed no later than April 17, 2018 in accordance with 40 CFR 257.100(b). After removal of CCR from the Surface Impoundments, the impoundment areas will be regraded back into the existing landscape and stabilized with vegetation. C.2 Surface Impoundment D Closure Description Surface Impoundment D will be closed in place, with a cover system that will be constructed in accordance with 40 CFR 257.100(b)(1) through (4). To prepare for closure, the upper portion of the CCR in Surface Impoundment D will be dewatered and graded to make the surface suitable for construction of the final cover system. 40 CFR 257.100 (b)(2)(i) requires that free liquids be eliminated by removing liquid wastes or solidifying the remaining wastes and waste residues. To meet this requirement, water ponded on the surface of the CCR impoundment will be removed and the CCR dewatered to a depth determined by a qualified professional engineer to provide a surface sufficiently stable for the installation of the final cover system. 40 CFR 257.100 (b)(2)(ii) requires the remaining CCR be stabilized sufficient to support the final cover system. To meet this requirement, the CCR impoundment will be dewatered as described above and earth fill from onsite or offsite borrow areas and the Surface Impoundment D embankment

Page 2 will be placed in the impoundment area to help raise the grade of the impoundment and create a slope for proper drainage. Closure will be accomplished by placing the final cover system consisting of geosynthetic and soil layers over the CCR surface to reduce and minimize infiltration of water into the CCR and minimize releases of CCR, leachate, or contaminated run-off to the ground, surface waters or atmosphere, as required by 40 CFR 257.100(b)(1)(i). An erosion resistant spillway channel meeting the requirements of 40 CFR 257.100(b)(1)(ii) will also be constructed to prevent future impoundment of run-on waters. 40 CFR 257.100(b)(1)(iii) requires that the final cover slope be stable. The majority of the final cover will be relatively flat (2 to 2.5 percent), but a portion of the Surface Impoundment D cover will be sloped at 4 horizontal (H) to 1 vertical (V). A drainage layer has been designed to reduce the potential for saturation of the steeper slopes during large rainfalls, and stability analyses calculated the shear strength of each final cover system material and interface that is required to achieve a recommended factor of safety of 1.5 for static conditions and 1.1 for seismic conditions at the designed slopes, based on current seismic classification(s). Material interfaces will be tested prior to construction to document that the required shear strength will be achieved. 40 CFR 257.100(b)(1)(iv) requires that the proposed closure design minimize the need for further maintenance of the surface impoundment. This closure design reduces the need for further maintenance by providing a permanent cap system that will be protected with 18 inches of protective cover soil. The soil cover will be topped with a six inch vegetative support layer to reduce erosion. The grades of the final cap will be designed to promote drainage with minimal erosion. The drainage channels will be constructed with turf reinforcement mats or other permanent erosion controls to reduce maintenance needs. The final cover design is in accordance with 40 CFR 257.100(b)(3)(i) for the closure of inactive CCR surface impoundments. The layers of the final cover system to be installed are described below (from top to bottom). Vegetation. Consists of combination of quick-cover vegetation, such as annual ryegrass, and easily maintained perennial grasses and legumes, such as Kentucky 31 Fescue and clover. The seed mix for the cap will be selected in accordance with the Virginia Erosion and Sediment Control Handbook recommendations. Vegetative Support Layer. Consists of six inches of soil that can sustain vegetation. This layer will consist of topsoil or site soil amended with appropriate nutrients to facilitate vegetative growth. The vegetative support layer will be spread by low-ground-pressure equipment and will be compacted only as required for access and stability. Protective Cover Soil Layer. Consists of an 18-inch-thick soil layer. The protective cover soil layer will store moisture and support vegetation. It will also act as a protective layer for the drainage and barrier layers. Drainage Layer. Consists of a geocomposite drainage net (GDN), which is a synthetic drainage net sandwiched between two pieces of geotextile fabric. This layer provides lateral drainage over the barrier layer. The geotextile filter fabric on the top of the GDN will allow the flow into the net while filtering out fine soil particles from the cover soil layer. The nonwoven geotextile fabric on the bottom of the GDN will act as a cushion to protect the 40-mil LLDPE geomembrane. Barrier Layer. This layer prevents water from infiltrating into the CCRs. The barrier layer will consist of a 40-mil LLDPE geomembrane. Cushion Geotextile (as needed). Consists of nonwoven geotextile that will act as a cushion to protect the 40-mil linear low-density polyethylene (LLDPE) geomembrane. This

Page 3 layer will be constructed directly on top of a prepared subgrade layer which may be CCR or earth fill. Cushion geotextile will not be needed where the prepared subgrade surface is smooth. The CCR in Surface Impoundment D was analyzed to evaluate the stability and settlement of the final cover system and assess that positive slopes will be maintained. Based on the results of the geotechnical investigation and settlement calculations, final slopes should remain at a minimum of 2 percent after settlement for overland areas and 1 percent for channels. This post-settlement slope meets the requirements of 40 CFR 257.100(b)(3)(i)(D). D. Closure Schedule Tables 1 and 2 below provide schedules for the closure of Surface Impoundments A, B, C, and E and Surface Impoundment D, respectively. Surface Impoundments A, B, C, D, and E ceased receiving CCRs before October 19, 2015. Construction activities related to the closure of the surface impoundments will be completed by April 17, 2018 in accordance with 40 CFR 257.100(b). Table 1. Surface Impoundments A, B, C, and E Construction Schedule Construction Activity Dispose of any remaining CCRs in Surface Impoundments A, B, C, and E at an offsite disposal facility. Lower the A, B, C, and E dam embankments, decommission dams, and construct temporary sediment basins in the former Surface Impoundments A, B, C, and E to control stormwater. Grade and fill former impoundment areas and establish vegetation in former Surface Impoundments A, B, C, and E areas after CCR is removed. Approximate Start Date Approximate End Date November 2015 April 2018 March 2016 September 2016 1 March 2016 April 2018 Closure of all surface impoundments complete. - April 17, 2018 Notes: 1 Temporary Sediment Basins will be removed once vegetation is fully established in accordance with Prince William County Sediment and Erosion Control requirements. Anticipated removal of temporary sediment basins is one year after permanent seeding of the closed impoundment areas.