INGRESS PROTECTION RATIO IP

Similar documents
IP DEFINITIONS. Technical Notes. Definitions. IPXX Code

1

Environmental Protection of HMI Components

Notes on equipment protection per EN/IEC and NEMA For Bourdon tube or diaphragm pressure gauges

Notes on equipment protection to DIN EN and NEMA

CTK Co., Ltd. (Ho-dong) 113, Yejik-ro, Cheoin-gu, Yongin-shi Gyeonggi-do KOREA, REPUBLIC OF Tel: Fax:

CTK Co., Ltd. (Ho-dong) 113, Yejik-ro, Cheoin-gu, Yongin-shi Gyeonggi-do KOREA, REPUBLIC OF Tel: Fax:

DC/DC Converter. Test item description...:

Introduction IP codes are used in electrical product catalogs, etc., to indicate waterproofness and so on.

FINAL VERSION VERSION FINALE

TEST REPORT EN Degrees of protection provided by enclosures (IP Code)

GENERAL APPLICATION NOTES

CUSTOM ENCLOSURE CUTOUTS

In Ground Buried Uplights

Intertek Testing Services Taiwan Ltd.

Session #: Selection of Explosion Protected Equipment for Hazardous Locations

TechNote FM APPROVAL: HAZARDOUS LOCATION EQUIPMENT CLASSIFICATION

Hazardous Location Coding System - NEC 500. Type of Protection. XP = Explosionproof. IS = Intrinsically Safe Apparatus

Further technical information is available on

Hazardous Location Coding System - For Division. Class I / II / III, Division 1 / 2 Type of Protection. XP = Explosionproof

DTG - LCD Digital Temperature Gauge USER MANUAL

High-performance submersible pressure transmitter For level measurement Model LH-10

E 094 E 103 E 143 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 135 l/min / 35.7 gpm

1.8 INDUSTRIAL PROCESS WEIGHING IN HAZARDOUS AREAS

TEST REPORT 545 EAST ALGONQUIN RD., SUITE F ARLINGTON HEIGHTS, IL USA. Project No. G August 12, 2013 Page 1 of 9

High-performance submersible pressure transmitter For level measurement Model LH-10

TEST REPORT IEC / EN Degrees of protection provided by enclosures (Ip code)

E 212 E 222 Tank top mounting Connection up to G1¼ / -20 SAE Nominal flow rate up to 220 l/min / 58.1 gpm

SR500 PAPR Copyright 2015 by The S.E.A. Group 1

High Pressure Tube Unions

Ultrasonic level transmitter and indicator

Sizing Enclosures for SCR Power Controllers

CP10 Sensor Installation and Maintenance Instructions

L3 Pressure and Level transmitter

Non-corrosive gas Liquid. Corrosive gas

Gas density monitor With integrated transmitter Model GDM-100-TI

Operating Instructions

Type N-10, N-11 Hazardous Area Non-incendive Transmitters

IEC Test Report for mini-box.com Report No. NF September 29, Test Report

Industrial Components Preventive Maintenance, Enclosures, and Contact Ratings Specifications

Related Products: Auto Drain Valve. Model/Specifications. Model

High-performance submersible pressure transmitter For level measurement Model LH-20

MODEL GT820 OXYGEN SENSOR

Air Sensor. SAC Ex. Manual ATEX. AQ Elteknik AB

Air Sensor. FCS Ex. Manual. AQ Elteknik AB

IP65 Test Report Issue by Design Technology Department Report No: 1605IP0667BR 8 Rugged Tablet PC : Taurus FM08 Rugged Tablet PC

Level transmitters and indicators Series LU Ultrasonic level transmitter and indicator for liquids and solids

General Accreditation Guidance. User checks and maintenance of laboratory balances

SDX Submersible Depth Transmitter User Manual

ISO INTERNATIONAL STANDARD. Pulps Determination of drainability Part 1: Schopper-Riegler method

High-performance submersible pressure transmitter For level measurement Model LH-20

High-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

Guideline No.M-05(201510) M-05 AIR COMPRESSOR. Issued date: 20 October China Classification Society

Pressure Measurement Single-range transmitters for general applications

Operation manual Level sensor DC-LS-50 Operation Manual Level Sensor DC-LS-50

E 441 E 451 E 461 E 641 E 700 Tank mounting Nominal flow rate up to 800 l/min

C I R E D 18 th International Conference on Electricity Distribution Turin, 6 th to 9 th June 2005

PRODUCT DATA SHEET (ver.02/ ) One flap non return valves ( mm) Double flaps non return valves ( mm)

E 212 E 222 Tank top mounting Connection up to G1¼ Nominal flow rate up to 220 l/min

SPWE Series. Setup Instructions. Version 2.0

Blue Whale Spa :- Site Preparation and Delivery

SDX Submersible Depth Transmitter User Manual

Monitoring device NTS 30

Best Practice Guide, Servomex 2700

RESOLUTION MSC.94(72) (adopted on 22 May 2000) PERFORMANCE STANDARDS FOR NIGHT VISION EQUIPMENT FOR HIGH-SPEED CRAFT (HSC)

Hot Tub Pre-Delivery Guide

Pipe-Away Pressure Vacuum Vent /Conservation Vent

Title: Standard Operating Procedure for R&R Environmental Devices Model MFC201 Gas Dilution Calibrator

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

FAS-W. Features. Applications. Automatic condensation hygrometer

COMMON PRECAUTIONS Data Sheet - Be Sure To Read Before Handling Page 1 of 6

Instructions for Installation, Use and Maintenance FSI Safety Tank Shower Systems

GATES, CATTLE GUARDS AND PASSAGEWAYS. This factsheet looks at various options for allowing passage through fences for livestock, wildlife and people.

MODEL WEIGH MODULE

BT6HC Hygienic Sanitary Balanced Pressure Steam Trap for High Capacity and CIP/SIP Applications

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC

FTS SUBMERSIBLE PRESSURE TRANSMITTER USER S MANUAL

How to specify a product. Process Sensors and Mechanical Instruments

PASSENGER SHIPS Guidelines for preparation of Hull Structural Surveys

Precision pressure sensor Basic version Model CPT6020

INSTRUCTION MANUAL TIPPING BUCKET RAIN GAUGE. MODEL TB3/0.1mm

TEST REPORT IEC / EN Degrees of protection provided by enclosures (Ip code)

Provided by. Personal Protective Equipment. Workers Health & Safety Division HS96-101C (07-04)

Hydrostatic. Continuous level measurement. Overview Page 188 VEGAWELL 52 Page 190 VEGABAR 86, 87 Page 192 Accessory Page 196 AL-EN

WP2 Fire test for toxicity of fire effluents

Pressure Automated Calibration Equipment

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)

Two-Wire In Situ Oxygen Analyzer (550 to 1400 C)

E 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm

High Pressure Breathing Air Compressors

Vortex Flow Meter Wafer or Flange Connection. - Steam - Liquid - Gas

Wire rope lubrication system. Increases wire rope life and reduces lubrication time, lubricant waste and environmental contamination

9700 Transmitter Submersible hydrostatic level transmitter

Personal Protective Equipment Policy

E 328 E 498 Tank top mounting Connection up to G1½ and SAE 2 Nominal flow rate up to 600 l/min

GA24 Technical Datasheet

Mechanical vibration Rotor balancing. Part 11: Procedures and tolerances for rotors with rigid behaviour

ML3M Monnier Miniature Compressed Air Lubricator

Transcription:

INGRESS PROTECTION RATIO IP This technical note is made for giving a brief explanation about the meaning and utilization of the classification system established by the IP code and IP ratings in general, and set recommendations for use of these codes for the load cells and weighing systems. Definitions Obteined from the International Electrotechnical Vocabulary (IEV 826 03 12): Ingress Protection Ratio: The level of protection provided by an enclosure against access to hazardous parts, against the penetration of solid foreign bodies, against the penetration of water or against external mechanical impacts, and also takes place by standardized test methods. Enclosure: This element provides protection against the effects of external material in any direction and protects against direct contact. The IP protection degrees are described in the European Standard EN 60529 as well as in other equivalent and/or complementary standards as UNE 20324, IEC 529, ISO 29653 and DIN 40050 9. IPXX CODE This code constists of 2 numbers placed inmediately after the letters IP, called first and second digit, and sometimes features a third chacarter appears further, optionally in order to provide additional information on the degree of protection. Explanation of the first characteristic numeral IPXX The first characteristic numeral indicates the protection of equipment against the penetration of solid foreign objects. IP Degree of Protection First Numeral Brief Description Brief indication on the objects should not enter the enclosure 0 Non Protected No particular protection 23 09 2011 INGRESS PROTECTION RATIO IP 1/5

1 Protected against bodies 50mm and greater 2 Protected against bodies 12mm and greater 3 Protected against bodies 2,5mm and greater 4 Protected against bodies 1mm and greater Solid objects with 50mm diameter or greater, for example, human hand. Solid objects with 12mm diameter or greater, for example, human fingers. Solid objects with 12mm diameter or greater, for example, tools, etc. Solid objects with 1mm diameter or greater, for example, wires. 5 Dust protected Ingress of dust is not totally prevented, but dust shall not penetrate in a quantity to interfere with satisfactory operation of the apparatus or to impair safety. 6 Completely dust protected No ingress of dust. Explanation of the second characteristic numeral IPXX The second characteristic numeral indicates the protection of equipment against the penetration of water. IP Degree of Protection Second Numeral Brief Description Type of protection provided by the encolsure 0 Non Protected No particular protection 1 Protected vertically falling water drops 2 Protected vertically falling water drops when the enclosure is tilted up to 15º 3 Protected against spraying water 4 Protected against splashing water 5 Protected against water jets Vertically falling drops of water from 200mm height above the device during 10 minutes ( falling 3 5 mm 3 per minute), shall have no harmfull effects. Vertically falling drops of water, when the enclosure is tilted at any angle up to 15⁰ on either side of the vertical, during 10 minutes ( falling 3 5 mm 3 per minute), shall have no harmfull effects. Water sprayed at an angle of up to 60⁰ on either side of the vertical, averaging of 10 liters/minute with a 80 100kN/m 2 pressure, during a period under to 5 minutes, shall have no harmful effects. Water splashed against the enclosure will enclosure from any direction, averaging of 10 liters/minute with a 80 100kN/m 2 pressure, during a period under to 5 minutes, shall have no harmful effects. Water projected by a 6,3mm. nozzle in jets against the enclosure from any direction, averaging of 12,5 liters/minute with a 30kN/m 2 pressure during a period NO under 5 minutes, shall have no harmful effects. 23 09 2011 INGRESS PROTECTION RATIO IP 2/5

6 Protected against powerful water jets and seaway 7 Protected against the effects of temporary immersion in water 8 Protected against the effects of continous immersion in water Water projected by a 12,5mm. nozzle in jets against the enclosure from any direction, averaging of 10 liters/minute with a 100kN/m 2 pressure during a period NO under 3 minutes and a distance NO under 3m, shall have no harmful effects. When totally immersed the encolusre in water, in a depth up to 1m and no longer to 30minutes, shall have no harmful effects Enclosure totally and continously immersed in a depth and time specified by the manufacturer and always in worse conditions than value 7. The common specification is 1m depth and 100h time. 9K Protected against highpresure jets The device is suitable to be used in aplications with high pressure jets, from any direction with 100 bar pressure, 80 C temperature, 15l/min. caudal and a distance no under 10cm. Special recommendations for weighing systems Solid bodies and/or dust: Althought most of the load cells, and associated electronic equipment, have their electronics protected enought against dust and solid bodies intrusions, we consider the weighing system must remain clean of dirt and dust to be able to move, in vertical and horizontal axis, with sufficient freedom to measure with high repeatability and accuracy, and, at the same time, we must consider to use external limitators to assure the stability and the safety suitable for the application. For that, the designers of the weighing systems must consider use aditional barriers, enclosures, shields, etc. as well as leaving enought space to avoid accrued dust will difficult correct measurements. Also we have to adopt a maintenance plan allowing a regular verification and cleaning, for example yearly, or whatever necessary according the specifications of the instalation. Water and moisture/humidity: In general the weighing equipment and load cells in particular, are very sensitive to moisture, due to handle signals of very few microvolts, produced by very small changes on the ohmic values in their extensiometric gauges. This circumstance makes that when load cells will be used in potentially moisture conditions we should extreme the ingress protection at maximum and we should prepare the instalation to ensure good drainage and water evacuation. Special attention should be taken on the instalation of cables and the conexion boxes ubication, to avoid floods and encouraging drainage and ventilation. Is also essencial a maintenance plan to verify and clean the dirt that accumulate humidity and prevent the proper drainage. In all of cases we must avoid prolongated immersions, whatever the degree of protection of the chosen equipment. IP selection guide to chose the apropiate load cell according to their application enviroment: Despite of the codes indicating the IP protection, and because their classification is based on relatively short term test, we will always select our equipment by using the principle of oversizing and maximize protection against water, considering a 23 09 2011 INGRESS PROTECTION RATIO IP 3/5

reliable and durable long term use. For this reason, the following recomendatios, even being oversized, are a good practice: o Indoor applications, always in dry places, with low ambiental humidity and without condensation ( Offices, stores, wharehouses, etc.) : Without any particular protection. o Indoor applications with sporadic water projections (Workshops, factories with normal cleaning with water, but not at high pressure, machines with no moisture/condesation inside, etc.): IP65 or higher. o Outdoor applications, under cover and potential splashes of water and/or rain (outdoor machinery with load cells protected under covers or housings, installations in buildings/floors with open sides exposed to rain, etc.): IP66 or higher. o Outdoor applications, opened to the wheather conditions, directly exposed to rain without protection covers (Outdoor tanks and silos, chemical or food industry without direct high pressure cleans and good drain, etc): IP67 or higher. o Applications in pit and/or places with high moisture and/or highly probable presence of water and/or sporadic and short floods (in pit pallet scales, in pit truck scales, etc.): IP68. o Applications with direct high pressure water jet cleaning (food/ chemical/pharmaceutical scales, on board vehicle scales with high pressure jets cleaning): IP69K. Comments, hot spots and other recommendations o The IP protection degree tests only includes the detrimental effect of the intrusion of solids and water in the enclosure of the equipment, but do not guarantee anything about the protection against the corrosion of the device, either internally or externally, for which we should complement their choice with other concepts, such as choosing the right construction materials and/or other applicable recommendations to each environment and use. o The hot spot to be protected against the malfunction of the load cell is preserve the moisture in their internal circuit, for this reason the most suitable cells are the fully made in stainless steel and hermetically sealed by welding metallic covers. There are manufacturers that specifies cells as IP68 and they are only protected with a silicon pot and a metal enclosures that are not hermetically welded, they will probably fail at medium/long term under high moisture conditions. o The end of external load cell cable and wires should be always preserved from the intrusion of water, for this reason we should connect them into a good quality junction box. o All good practices of the sector and application of use will be kept. o The quality and reliability of the equipment in general is inside the details, in the design and in the manufacturing of the product, and it is very important as well to make a good installation. From Utilcell we hope that this technical note can be of help to know and understand the IP ratings. It is done only as a guideline and will not serve as a contractual specification. The specifications of each product should be consulted on his data sheet as well as in the standards to 23 09 2011 INGRESS PROTECTION RATIO IP 4/5

which reference is made. We reserve the right to change the content of this technical note at any time without previous notice. We will remaining at your disposal for any further information. 23 09 2011 INGRESS PROTECTION RATIO IP 5/5