TANDEM MODULATOR FOR OUTLET GAS FLOW: STEPPED (836 TANDEM) - CONTINUOUS (837 TANDEM) SERVO-CONTROLLED PRESSURE REGULATOR

Similar documents
MULTIFUNCTIONAL CONTROL FOR GAS BURNING APPLIANCE

SIT Group 710 MINISIT MULTI-FUNCTIONAL GAS CONTROL THERMOELECTRIC FLAME SUPERVISION DEVICE PRESSURE REGULATOR TEMPERATURE CONTROL PIN 0085AQ0287

828 NOVAMIX ENGLISH - ITALIANO - FRANCAIS - DEUTSCH - NEDERLANDS - ESKY

GasBloc Multifunctional gas control Combined regulator and safety shut-off valves single-stage atmospheric operating mode GB-(LEP) 057 D01

Old documentation - Only for your information! Product is not available any more!

VR46.5V(A)/VR86.5V(A) SERIES

VK41../VK81.. GAS CONTROLS FOR COMBINED VALVE AND IGNITION SYSTEM SPECIFICATIONS APPLICATION DESCRIPTION INSTRUCTION SHEET

GasBloc Multifunctional gas control Combined regulator and safety shut-off valves Electrically modulating GB-M(P) 055 D01

Old documentation - Only for your information! Product is not available any more!

GasBloc Multifunctional gas control Combined regulator and safety shut-off valves Integrated gas-air system GB-GD 057 D01

QPL... Pressure Switches. Siemens Building Technologies HVAC Products

WhirlWind Multifunctional gas control Fully integrated gas-air system with control and safety function GB-WND 055 D01

VRB00 Series CLASS B SERVO REGULATED COMBINATION VALVES

VR400/VR800 SERIES. Honeywell CLASS A SERVO REGULATED COMBINATION VALVES APPLICATION. Contents PRODUCT HANDBOOK

GS-20/25 and GS-40/45 Series Single-block Multi-function Gas Control Valves

Installation, use and maintenance instructions. Gas burner (5)

Operator: Save these instructions for future use!

GasMultiBloc Combined regulator and safety valve Infinitely variable air/ gas ratio control mode MBC-300-VEF MBC-700-VEF MBC-1200-VEF

VR400/VR800 SERIES. Honeywell CLASS A SERVO REGULATED COMBINATION VALVES APPLICATION DESCRIPTION INSTRUCTION SHEET

WhirlWind Combined fully integrated gas/air control and safety system GB-WND 055 D01

UL Listed GM-20/25 and GM-40/45 Series Dual-block Multi-function Gas Control Valves

Tightness controls TC 1 3 and TC 4

36E DSI, HSI & Proven Pilot Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

Governor with solenoid valve VAD Air/gas ratio control with solenoid valve VAG

GM Series Dual-Block Multi-Function Gas Control Valves

Old documentation - Only for your information! Product is not available anymore!

Tightness control TC. Product brochure GB 3 Edition AGA

36E DSI and HSI Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

Dual Solenoid Gas Valve Installation

SOLENOID VALVES AND PNEUMATIC VALVES

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

Compact pressure switches for gas and air

36H SERIES Combination Gas Valve

4/2 way Pneumatic Solenoid Valve

GM-7000 Series CE Approved Gas Control Valve

Prop. 3-Way Pressure-Reducing Cart., Size 5 / SAE 08

VK41../VK81..SERIES GAS CONTROLS FOR COMBINED VALVE AND IGNITION SYSTEM APPLICATION. Contents PRODUCT HANDBOOK

Solenoid gas valve. The solenoid gas valve is also applicable as a main gas valve Pilot gas valve for forced draft burners

HUPF Series DESCRIPTION APPLICATION INSTRUCTION SHEET GAS PRESSURE REGULATOR WITH INCORPORATED FILTER EN1C-0003NL05 R1205.

Data sheet Pressure switch type CS December 2001 DKACT.PD.P10.A B1119

36E03 and 36E38 DSI and HSI Step Opening Combination Gas Valve INSTALLATION INSTRUCTIONS

BGC258 Series BASOTROL Gas Valve

VR400/VR800 SERIES UNIVERSAL GAS VALVES CLASS A SERVO REGULATED COMBINATION VALVES APPLICATION. Contents PRODUCT HANDBOOK. General.

VMR VMR-OTN VMR 6 bar

Dual fuel Gas-Oil/Gas burner

VK41../VK81..SERIES GAS CONTROLS FOR COMBINED VALVE AND IGNITION SYSTEM APPLICATION. Contents PRODUCT HANDBOOK

VR400/VR800 SERIES UNIVERSAL GAS VALVES CLASS A SERVO REGULATED COMBINATION VALVES APPLICATION. Contents PRODUCT HANDBOOK

Pressure regulator with solenoid valve VAD Air/gas ratio control with solenoid valve VAG

MV-01. Features. 2/2-way Solenoid Valve for Fluids. Description: Application:

Pressure regulator with solenoid valve VAD Air/gas ratio control with solenoid valve VAG Variable air/gas ratio control with solenoid valve VAV

BGA158 Series CE Approved Class B Shutoff Gas Valve

BGA158, BGA171 and BGA110 Series Shutoff Gas Valve

Solenoid valves VZWF, force pilot operated

1 LS unloading (control valve, orifice, none) 2 LS max pressure relief. 3 Spool type

Inverse Proportional Pressure-Relief Cart., Size 2 4

3-Way Safety Block DSV

Electrically Operated Pressure-Relief Cartridge, Size 10

SV - Safety Shutoff Valve with Proof of Closure 1/2" NPT - 2" NPT. SV/614 Series SV-DLE/614 Series

BGA158 Series CE Approved Class A Shutoff Gas Valve

PVQ 13 A2 R SE 1 S 20 C-11 D

Proportional Pressure-Relief Cartridge Valve, Size 2...4

filtered air without lubricant. If lubricated air is used, it is recommended to use ISOVG32 oil and to never interrupt lubrication.

Intrinsically safe solenoid valves on/off controls - ATEX certification

Gas Pressure Regulator HON 300

Proportional Throttle Cartridges, Size 16

Inverse Proportional Pressure-Relief Cartridge, Size 10

SPCH/ Blowing block

SPECIFICATIONS ATTENTION

INSTRUCTION MANUAL Pressure Relief Device LPT

MECAIR CSN RAINTIGHT ENCLOSURE CLEAN AIR SOLUTIONS PRODUCT LEAFLET

EVRM-NC EVRM-6NC. delta-elektrogas.com. Safety solenoid valves for gas Manual reset - Normally closed DN10 DN300.

Filling valves AL, ALM Series Automatic filling units ALOMDIW, ALOMDNW Series

Operator: Save these instructions for future use!

SPECIFICATIONS CAPACITY

Safety. Operating instructions Filter module VMF Measuring orifice VMO Fine-adjusting valve VMV DANGER. Contents WARNING CAUTION

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

Dual Modular Safety Shutoff Valves with Two-stage operation. DMV-ZRD/602 Series DMV-ZRDLE/602 Series

Owner s Manual Installation and Operation

GasMultiBloc Combined regulator and safety shut-off valves Single-stage function MB-D(LE) B01

VR8104, VR8204, and VR8304 Intermittent Pilot Combination Gas Controls

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

Modulating Valves for Atmospheric, Infrared, and Direct Fired Burners

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R

Operator: Save these instructions for future use!

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 09.14

G92 Series BASOTROL Automatic Pilot Gas Valve

Proportional Pressure-Relief Cartridge Valve, Size 2...4

V46../V86.. series COMPACT COMBINATION GAS CONTROLS APPLICATION. Contents page Description... 2 Features... 3 PRODUCT HANDBOOK.

V5197A. Firing Rate Gas Valve APPLICATION FEATURES PRODUCT HANDBOOK

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

Safety and Shut-off Block SAF/DSV

Valve Proving System VDK 200 A S06*

G96 Series BASOTROL Dual Operator Valve

Pneumatic valve islands

Inverse Prop. Pressure-Relief Cart., Size 2 4

Valve Proving System VDK 200 A S02

TECHNICAL CHARACTERSTICS

Inverse Proportional Pressure-Relief Cart., Size 2 4

VK42.. / VK82.. SERIES

36C/36D HSI, DSI Proven Pilot Gas Valves INSTALLATION INSTRUCTIONS

Transcription:

SIT Group 836-837 TANDEM MULTIFUNCTIONAL GAS CONTROL MODULATOR FOR OUTLET GAS FLOW: STEPPED (836 TANDEM) - CONTINUOUS (837 TANDEM) SERVO-CONTROLLED PRESSURE REGULATOR ALL ADJUSTMENTS ACCESSIBLE FROM ABOVE PIN 63AP7060/4

ELECTRICALLY MODULATED AUTOMATIC MULTIFUNCTIONAL CONTROL Multifunctional control with two near-silent automatic on-off valves, fitted with electrically modulated stepped (836 TANDEM) or continuous (837 TANDEM) gas flow. Servo-controlled pressure regulator. 836-837 TANDEM is suitable for appliances for catering, water heating and convector heaters, fitted with automatic ignition and flame supervision systems, which require the regulation of the gas flow as a function of the temperature. MAIN FEATURES Electric modulator of the gas outlet pressure: stepped (836 TANDEM) or continuous (837 TANDEM). Two near-silent automatic shut-off valves in class B (class A on request). Servo-controlled pressure regulator. Pilot outlet (optional) with gas flow restrictor. Inlet and pilot filters. Inlet and outlet pressure test points. Threaded gas inlet and outlet with provision for flange connection. Connection for pressure regulator/combustion chamber compensation. Data refer to EN 6

DESCRIPTION 1 On-off solenoid valve EV1 2 Gas outlet pressure modulator 3 Adjustment screw for gas flow to the pilot 4 Inlet pressure test point Outlet pressure test point 6 On-off solenoid valve EV2 7 Pilot outlet 8 Main gas outlet 9 Holes (M4) for fixing flanges 10 Connection for pressure regulator / combustion chamber compensation 2 4 3 7 10 1 6 9 8 TECHNICAL DATA Gas connections: Rp 1/2 ISO 7 Installation position: any position Gas families: I, II and III Maximum gas inlet pressure: 60 mbar Working temperature range: 0... 60 C (-20... +60 c on request) Pressure regulator: Class C Automatic solenoid valves Class B (Class A on request) 836 TANDEM stepped modulator - outlet gas pressure setting range: - max. pressure 7-0 mbar (230V version: 7... 37 mbar) - min. pressure 2-4 mbar (230V version: 2... 30 mbar) 837 TANDEM continuous modulator - outlet gas pressure setting range: 2-20 mbar (white screw) on request 3-37 mbar (red screw) on request 7-0 mbar (black screw) POWER SUPPLY STEPPED MODULATOR (836) CONTINUOUS MODULATOR (837) Voltage Consumption Voltage Consumption (rectified AC) (ma) (DC) (ma) 230 V 27 220 V max 2 max 24V 270 28 V max 16 max 16 V max 310 max SAFETY SOLENOID VALVES EV1 + EV2 Class A Class B Low Power vers. Voltage (AC) Consumption (ma) Consumption (ma) Consumption (ma) 230 V 0 Hz 80 80-220 V 60 Hz - 90-24 V 0 Hz 900 80 00 24 V 60 Hz - 900 600 Electrical protection rating IP4 with 10 type connectors. Data refer to EN 6

DIMENSIONS SMD 104 n6. 22 4 2 108 17 Rp1/2 Rp1/2 22 n M4 28 27. 32 3 17 18 11 140 10 96. 27. 32 28 60 n M4 EV1 EV2 PILOT I STEP 3 2 17. EV1 COM 17 33 21 24. EV2 26 9 FLOW RATE AS A FUNCTION OF PRESSURE DROP Q [m 3 /h 3 /h d=0.6] d=0.6] 7 6 CLASS B+B 4 3 2 CLASS B+B I Family (d = 0.4) Q = 4.8 m 3 /h p = mbar II Family (d = 0.6) Q = 4.2 m 3 /h p = mbar III Family (d = 1.7) Q = 2.8 kg/h p = mbar 1 0 1 2 3 4 6 7 8 9 10 11 p [mbar] p

OPERATION Reading the inlet pressure The inlet pressure can be read at the pressure test point E with or without both on-off solenoid valves energized. Pilot burner ignition When the automatic shut-off valve EV1 is powered, it permits the gas to supply the pilot burner outlet (applications with intermittent pilot) after passing through the inlet filter, the pilot filter and the pilot flow rate restrictor (PILOT). Main burner ignition When both automatic valves, EV1 and EV2, are energized, gas passage to the main burner is opened. Outlet pressure The outlet pressure is read at the test point A. E PILOT A EV1 EV2 REGULATED FLOW RATE IN ACCORDANCE WITH EN 88 Q [m 3 /h d=0.6] Qgas [m 3 /h d=0.6] 8 7 6 4 3 2 1 0 7 8 9 10 11 13 2H 2L 14 1 16 17 Pu [mbar] POUT [mbar] CLASS B+B Inlet pressure range (mbar) Gas type Nominal Max. Min. 2H 20 2 17 2L 2 30 20 Outlet pressure tolerance +10%...-1% 837: CHARACTERISTIC CURVES OF THE CONTINUOUS MODULATOR Vertical position Horizontal position Outlet pressure POUT (mbar) 20 Outlet pressure POUT (mbar 20 1 1 10 10 0 0 0 100 10 Current intensity (ma) 0 0 0 100 10 Current intensity (ma) VERSION 2...20 mbar

INSTALLATION Main gas connection The connection is made using gas pipes with Rp 1/2 ISO 7 threading. Torque: 2 Nm. If, alternatively, flanges (available on request) are used, first screw the pipes onto the flanges and then the flanges to the valve. Recommended torque for the flange fixing screws: 3 Nm. Connection to the pilot burner Pipes with a 4 mm, 6 mm or 1/4 Ø can be used. Use a nut and olive of appropriate dimensions. Tighten to 7 Nm torque. Connection to the combustion chamber Pressure regulator / combustion chamber compensation is possible when the latter is pressurized (see figure). Electrical connections Use the special connectors for the connection of the mains-powered versions. To ensure that the valve is connected to the earth circuit of the appliance it is necessary for the power connector, which includes the earth terminal, to be used at all times and secured by means of the associated screw. The 24Vac versions must be powered by means of an isolating transformer (with a very low safety voltage to EN 60742). Use terminals AMP 6.3 x 0.8 mm, DIN 46244 for the connection. Carry out the connections in accordance with the rules for the appliance. The electrical safety cut-off devices (for example the flame supervision device, limit thermostat, and the like) must cut off the power supply to both solenoid valves. Stepped modulator connection (836 TANDEM) The stepped modulator must be powered by rectified voltage. Type 30 connectors with an integrated rectified circuit should be used; otherwise insert a diode bridge and a voltage limiter, appropriately dimensioned, into the circuit. CAUTION: after making the connections, check gas tightness and electrical insulation. V~ SMD Stepped modulator connection (836 TANDEM)

SETTINGS AND ADJUSTMENTS Measurement of the inlet and outlet pressure The inlet and outlet pressures of the gas can be measured by unscrewing the provided test point sealing screws. Replace screws with 2. Nm torque. Outlet pressure adjustment Maximum pressure: power the modulator in the maximum condition - screw in the nut (B) to increase outlet pressure and screw it out to decrease it. Minimum pressure (make this adjustment only after adjusting the maximum pressure): cut off the power supply to the modulator and, keeping the nut (B) blocked, screw in the screw (A) to increase the pressure and unscrew it to decrease it. Put back the protective plastic plug (C). Gas flow-rate adjustment to the pilot Screw in the associated screw to reduce the flow or unscrew it to increase flow. Overriding gas flow-rate adjustment to the pilot It is sufficient to screw the adjustment screw in flush and then screw it out two complete turns. Changing the gas family or group Check suitability for use with the gas family or group of interest. Following the instructions given above, adjust the outlet pressure to the values indicated in the instruction booklet of the appliance. C CAUTION: Check tightness and efficiency and seal the adjustment devices. A B Implement the provisions in the Use and Maintenance manual - code 9.96.836, code 9.96.837 - for installation, adjustment and use. Outlet pressure adjustment

836-837 TANDEM Multifunctional control with double solenoid valve and electrical flow modulator for gas appliances fitted with automatic ignition and flame supervision systems which require the regulation of the gas flow as a function of the temperature. 9.9.997 R00 GRAPHIC DESIGN BY START - PD - ITALY