Operation and Maintenance Manual

Similar documents
Operation and Maintenance Manual

Operation & Maintenance Manual GDS-68XP

Operating Instructions

FLAMMABLE GAS SENSOR/TRANSMITTER

Technical Manual. Sensepoint XCD Gas Detector

USER'S MANUAL HOT-WIRE TYPE GAS SENSOR NAP-100A SERIES ( NET10A(R) ) (For All Combustible Gases)

SEC Signature DIR Process Monitor

MODEL GT820 OXYGEN SENSOR

Ultima. XI Infrared Gas Monitor

9700 Transmitter Submersible hydrostatic level transmitter

LK-SX CO 2 +VOC. Application. Security Advice Caution. Notes on Disposal

XMO2. Panametrics Smart Oxygen Analyzer. Applications. Features. bhge.com. An oxygen transmitter for use in:

Electro-Pneumatic Converter YT-940 SERIES

White Paper. Chemical Sensor vs NDIR - Overview: NDIR Technology:

Transmitter CS 21 Operation Manual

CSA Sample Draw Aspirator Adapter Operator s Manual

RK-IR Sample Draw Aspirator Adapter Operator s Manual

Type N-10, N-11 Hazardous Area Non-incendive Transmitters

OSAT Series. Intrinsically Safe Infrared Temperature Sensor Operator's Guide

Transmitter CS 21 Operation Manual

FTS SUBMERSIBLE PRESSURE TRANSMITTER USER S MANUAL

CALIBRATION KIT. Instruction Manual

Sensoric 4-20 ma Transmitter Board Operation Manual

Detcon MicroSafe Model DM-534C Oxygen Deficiency Sensor (0-25% O2)

Verification Of Calibration for Direct-Reading Portable Gas Monitors

Features. Description

SPECIFICATIONS ATTENTION

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

CC Operation Manual Oak Valley Drive, Suite 20, Ann Arbor, Michigan USA fax

INSTRUCTION MANUAL MP4AR Remote Convection Gauge Range: 1 x 10-3 Torr to 1 x 10+3 Torr

Flow and Energy Measurement F-5400 THERMAL MASS FLOW METER

780S Ultra High Purity Series

EASIDEW TRANSMITTER with Current Source Output

Datasheet: K-30 ASCII Sensor

Ultima. X Series Gas Monitor

210 Series Transmitter with External Electrochemical Sensor

Table of Contents. Sensor Calibration and Troubleshooting CDS4000 CO 2. Introduction 1. Handling Information. Calibration 2.

Applications Note: Use of "pentane equivalent" calibration gas mixtures

Two-Wire In Situ Oxygen Analyzer (550 to 1400 C)

Sensepoint XCD. Calibration Guide

User Manual. GPL 3000 e. gas detector

AMT-Ex Dewpoint Transmitter

Hot extractive multi-channel gas analyser for continuous process and emissions monitoring.

GG-VL2-NH3 AMMONIA VENT LINE SENSOR. Installation and Operation Manual

Electropneumatic Transducer (I/P) Installation, Operation and

SX -X Concentration transmitter for flammable/ toxic gases Zone 1 ATEX (Cat. 2) Ex d IIB+H2 T6 Gb Ex tb IIIC T85 C Db IP6X

GasSense NDIR User Manual

ACV-10 Automatic Control Valve

The Ins and Outs of I/P Transducers

Supplementary Operator s Manual 42/24-14 EN Rev. 3

METHOD 25A - DETERMINATION OF TOTAL GASEOUS ORGANIC CONCENTRATION USING A FLAME IONIZATION ANALYZER

Columbus Instruments

GASGUARD VENT LINE3 Ammonia Sensor OPERATING & INSTALLATION MANUAL

combustion efficiency monitoring Flue gas oxygen analyzers General Purpose Applications Combustion & Environmental Monitoring

GAS DETECTION: CALIBRATION GAS

MASS FLOW SYSTEMS MASS FLOW MEASURING, CONTROLLING AND BLENDING SYSTEMS

How to specify a product. Process Sensors and Mechanical Instruments

GAS FUEL VALVE FORM AGV5 OM 8-03

Design Features. General Description

combustion efficiency monitoring General Purpose Applications Flue gas oxygen analyzers Combustion & Environmental Monitoring An Company

Brooks TMF-Zone 1 Models 5816-Ex/5864-Ex

BI-680 Online Dissolved Oxygen Controller Instruction Manual

P9000 DESCRIPTION. For parts requiring RoHS compliance, please contact factory. P February /6

EX-5150-MOS Sensor/Transmitter For PPM or %LEL Manual

I/P Transducer Positioner Module

Alphasense 4-20 ma transmitters offer convenience and easy maintenance for toxic sensors:

HLM-2000-TX Gas Transmitter User Manual

Portable Gas Monitor GX User Maintenance Manual (H4-0050)

Preferred Instruments Danbury, CT USA

analytical bulk flow distance FLOW level pressure temperature industrial communication

C-Flow Coriolis Mass Flow Meters

TECHNICAL DATA. Trimpac 244a. September 16, 2013

CO, NO, NO 2, NO x, SO 2, CH 4, HCl, CO 2 & H ² O. Extractive low cost, low maintenance devices for continuous process and emissions monitoring.

PURA. Pure Gas Dewpoint Transmitter. Users Guide

Model PDT Dewpoint Transmitter

Autocalibration Systems For In Situ Oxygen Analyzers

Using the UltraRAE. Firmware 2.35

Simrad GD10P Extended On-site Maintenance

Title: Standard Operating Procedure for R&R Environmental Devices Model MFC201 Gas Dilution Calibrator

Technical Data Sheet MF010-O-LC

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases

HLM-2000-TX Gas Transmitter User Manual

Best Practice Guide, Servomex 2700

Operation manual Level sensor DC-LS-50 Operation Manual Level Sensor DC-LS-50

Specifications of Oxygen Sensor Module V-8344A

DeltaSpan Pressure Transmitters LD10 Series Owner s Manual

LK-SX VOC. Application. Security Advice Caution. Notes on Disposal. Combined sensor mixed gas. Data sheet

MODELS (2 foot Version) (4 foot Version)

OC Panel High Limit Aquastat Kit, Manual Reset p/n

BUBBLER CONTROL SYSTEM

RGC-IR Remote Gas Calibrator for IR400

DF-310E PROCESS ANALYSERS APPLICATIONS FEATURES

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

AND EQUIPMENT FOR ENVIRONMENTAL APPLICATIONS (800) B Polk Street Houston, TX

G92 Series BASOTROL Automatic Pilot Gas Valve

1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure

TECHNICAL DATA. Trimpac 251a. Spetember 16, 2013

TEL/jlRE" Introduction. Display Features and Modes. Startup Procedure. Power-Up Procedure. Adjustment Modes

Gas-Detection Instruments

Bubble Tube Installations

Transcription:

Operation and Maintenance Manual GDS-50 Remote Infrared Sensor Transmitter for Combustibles & CO 2 AUTHORIZED DISTRIBUTOR: GasDetectorsUSA.com - Houston, Texas USA sales@gasdetectorsusa.com - 832-615-3588

CAUTION: FOR SAFETY REASONS THIS EQUIPMENT MUST BE OPERATED AND SERVICED BY QUALIFIED PERSONNEL ONLY. READ AND UNDERSTAND INSTRUCTION MANUAL COMPLETELY BEFORE OPERATING OR SERVICING. ATTENTION: POUR DES RAISONS DE SÉCURITÉ, CET ÉQUIPEMENT DOIT ÊTRE UTILISÉ, ENTRETENU ET RÉPARÉ UNIQUEMENT PAR UN PERSONNEL QUALIFIÉ. ÉTUDIER LE MANUE D INSTRUCTIONS EN ENTIER AVANT D UTILISER, D ENTRETENIR OU DE RÉPARER L ÉQUIPEMENT. REVISION HISTORY Revision 1.0 5/1/13 First release Copyright 2013 GDS Corp. All Rights Reserved P/N 1200-0734-01 GDS Corp Page 2 info@gdscorp.com

Table of Contents 1 SAFETY INFORMATION... 4 WARNINGS... 4 2 GENERAL INFORMATION... 5 INFRARED SENSORS... 5 3 SPECIFICATIONS... 6 4 INSTALLATION... 8 CHOOSING A LOCATION... 8 ELECTRICAL CONNECTIONS... 9 5 CALIBRATION... 10 CALIBRATION OVERVIEW... 10 GENERALIZED CALIBRATION PROCEDURE... 10 6 OPERATION AND MAINTENANCE... 12 SENSOR REPLACEMENT... 12 7 SPARE PARTS... 14 8 DRAWINGS AND DIMENSIONS... 15 List of Figures Figure 3-1: Sensor Types... 7 Figure 4-1: GDS-50 Enclosure... 8 Figure 4-2: GDS-50 Wiring Connections... 9 Figure 5-1: Applying Calibration Gas to GDS-50... 11 Figure 6-1: Sensor Replacement... 13 Figure 8-1: GDS-50 Dimensions... 15 GDS Corp Page 3 info@gdscorp.com

1 SAFETY INFORMATION Important Read Before Installation Users should have a detailed understanding of GDS-50 operating and maintenance instructions. Use the GDS-50 only as specified in this manual or detection of gases and the resulting protection provided may be impaired. Read the following WARNINGS prior to use. WARNINGS The GDS-50 sensor transmitter described in this manual must be installed, operated and maintained in accordance with information contained herein. Installation in any hazardous area must comply with all applicable restrictions, requirements and guidelines for said hazardous areas. It is the end user customer s final decision to ensure that the GDS-50 is suitable for the intended use. The GDS-50 is designed and constructed to measure the level of certain gases in ambient air. Accuracy in atmospheres containing steam or inert gases cannot be guaranteed. Always mount the sensor head vertically with the sensor head facing down. Do not paint sensor assembly. Do not operate the GDS-50 if its enclosure is damaged or cracked or has missing components. Make sure the cover, internal PCB s and field wiring are securely in place before applying power. Do not expose the GDS-50 to electrical shock or continuous severe mechanical shock. Protect the GDS-50 and related sensor assemblies from dripping liquids and high power sprays. Calibrate with known target gas at start-up and check on a regular schedule, at least every 90 days. More frequent inspections are encouraged to spot problems such as dirt, oil, paint, grease or other foreign materials on the sensor head. Periodically test for correct operation of the system s alarm events by exposing the monitor to a targeted gas concentration above the High Alarm set point. Use only for applications described within this manual. GDS Corp Page 4 info@gdscorp.com

2 GENERAL INFORMATION The GDS-50 Remote Infrared Sensor Transmitter is designed to measure combustible hydrocarbon gases including methane, propane, ethane, ethanol and many others, as well as both ppm level and percent-by-volume levels of carbon dioxide. The GDS-50 is ideally suited for installation where reliability and cost are critically important and where a local display is not required. The GDS-50 has the following key features: Standard 4 to 20 ma output (current source) High performance SmartIR infrared sensor with integrated IR source, dual channel receiver, temperature compensation and fault detection. Field-replaceable sensor element Remote fault indication for sensor fail or missing sensor (at controller) Powder-coated aluminum enclosure with 316 stainless steel sensor head Enclosure certified for use in Class I Division 1, Groups B, C & D hazardous areas NOTE: THE GDS-50 DOES NOT HAVE INTERNAL ZERO AND SPAN CALIBRATION ADJUSTMENTS AND MUST BE USED WITH A CONTROLLER THAT PROVIDES LOCAL CALIBRATION CAPABILITY. ALL GDS CORP CONTROLLERS OFFER THIS FEATURE. INFRARED SENSORS use an infrared light source to detect hydrocarbons. Carbon-hydrogen bonds in most common hydrocarbon molecules absorb certain frequencies of infrared light. As a result, when any hydrocarbon gas passes between the infrared source and detector, the detector output drops, indicating the presence of gas. A reference beam that is not affected by H-C bonds is used to monitor changes in source intensity and eliminate false alarms. GDS Corp SmartIR infrared sensors contain fully integrated source, receiver and microprocessor-based circuitry to perform this function. GDS Corp Page 5 info@gdscorp.com

3 SPECIFICATIONS Model: Power Input: Display: Sensor: Accuracy: Repeatability: Temperature Performance: Long Term Zero Drift: Calibration: Warm-up Time: Output: Response Time: Temperature: Fault Indication: Housing: Approvals: Warranty: GDS Corp GDS-50 Remote Infrared Sensor Transmitter for Combustible Gases and Carbon Dioxide 4-20mA current output; power consumption less than 2.0 watts max in over-range condition. None Type 10-96xx direct connect voltage output SmartIR infrared sensors for combustible and carbon dioxide. ± 2% full scale @ 20 C (68 F), 1 bar pressure, applied gas; 2.5% volume methane Zero: ± 1% full scale at 20 C ambient Span: ± 2% full scale at 20 C ambient ± 10% of reading up to 50% full scale, ± 15% of reading from 50% to 100% full scale, or 2% full scale whichever is greater over the range -20 C to +50 C (-4 F to 122 F) ± 1% full scale per month @ 20 C (68 F) ambient, (max ± 3% full scale per year) Output is factory adjusted but is not calibrated. Receiving device must provide zero and span (two-point) calibration. The GDS-50 is compatible with all GDS Corp controllers with bridgestyle inputs that provide two-point calibration capability. Sensor warm-up to final zero ± 2% full scale in one minute at 20 C ambient. GDS Corp recommends a one hour warm-up before attempting final calibration Uncalibrated 4-20mA (current source). Maximum loop resistance is 600 ohms with nominal 24V power supply. Less than 30 seconds (T 90 ) at 20 C ambient Less than 10 seconds (T 50 ) at 20 C ambient -20 C to + 50 C operating Zero volt output for sensor fail or sensor missing Junction box epoxy-coated aluminum, sensor head 316 stainless steel. Enclosure CSA certified for use in Class 1, Division 1, Groups B, C and D Explosion Proof area. Two years on electronics, one year on sensor GDS Corp Page 6 info@gdscorp.com

Sensor Target Gas Range % by volume Comments 50 Methane 0-100 % LEL 0 5% Fully characterized over temp range 51 Propane 0-100% LEL 0 2% Fully characterized over temp range 52 Methane 0-100% v/v 0 100% Fully characterized over temp range 53 Carbon Dioxide Multiple Ranges Multiple Ranges Range 0-2000 ppm to 0-100% v/v 54 Propylene 0-100% LEL 0 2% Fully characterized over temp range 55 Butane 0-100% LEL 0 2% Fully characterized over temp range 56 Pentane 0-100% LEL 0 2% Fully characterized over temp range 57 Ethylene Oxide 0-100% LEL 0 3% Fully characterized over temp range 58 Ethane 0-100% LEL 0 3% Fully characterized over temp range 59 Hexane 0-100% LEL N/A Output linearized for hexane 5A Acetone 0-100% LEL N/A Response factor based on propane 5B Ethane 0-100% LEL 0 3% Fully characterized over temp range 5C Ethanol 0-100% LEL N/A Response linearized for ethanol 5X Specify Gas TBE -20 C to + 50 C Contact Factory Figure 3-1: Sensor Types GDS Corp Page 7 info@gdscorp.com

4 INSTALLATION CHOOSING A LOCATION Factors such as air movement, gas density, emission sources and environmental variables affect sensor location. Air movement by fans, prevailing winds and convection should be carefully evaluated to determine if a leak is more likely to raise gas levels in certain areas within the facility. Vapor density of a gas determines if it will rise or fall in air when there are no significant currents. Lighter than air gases should have the monitors mounted 12 18 inches (30 45 cm) above the potential gas leak and heavier than air gases should be this distance below. Even though the GDS-50 sensor transmitter is designed for rugged service, it should be protected from environmental damage due to water, snow, shock, vibration or dust / dirt. The GDS-50 should always be mounted with the sensor head opening facing down. If necessary, a Splash Guard (p/n 10-0198) should be attached if there is any chance that water or liquid spray could enter the sensor opening from below. Be sure to leave sufficient room (~ 12 ) below the sensor head to allow easy access for attachment of a Calibration Cup and / or removal of the sensor head cover for sensor replacement. ¾ NPT Female (2) 0.25 dia (2) 5 spacing Figure 4-1: GDS-50 Enclosure GDS Corp Page 8 info@gdscorp.com

ELECTRICAL CONNECTIONS The GDS-50 is a three-wire 4-20mA output sensor that requires +24V and outputs an uncalibrated 4-20mA signal to the remote controller or receiver. Incorrect wiring can result in sensor damage or failure. +18 36V IN 4-20mA OUT GND Three-wire connection PWR ma OUT GND to remote receiver or controller PWR Figure 4-2: GDS-50 Wiring Connections Shielded cable is always recommended and should never be run in conduit with high voltage AC power wiring. When power is initially applied to the GDS-50 the output may momentarily indicate a temporary off-scale low (FAULT) or off-scale high (OVERRANGE) value before settling down. All GDS Corp controllers provide a warm up interval during which the sensor input is ignored. This keeps the controller from indicating an alarm due to sensor warm-up characteristics. Total warm-up time is dependent on the type of sensor and range selected. GDS Corp recommends a four to eight hour interval between initial power-on and first calibration. If the sensor has been powered up, and has only been offline for a few hours, the warm-up time will be shorter. GDS Corp Page 9 info@gdscorp.com

5 CALIBRATION CALIBRATION OVERVIEW The GDS-50 does not have the capability to perform zero and span calibration. Final zero and span calibration must be performed by the controller or receiving device. Follow these GDS-50 calibration guidelines: Calibration accuracy is only as good as the calibration gas accuracy. GDS Corp calibration gases are traceable to NIST (National Institute of Standards and Technology). Never use calibration gas that has passed its expiration date. Always use a GDS Corp calibration cup that completely surrounds the sensor head. Be sure to use ZERO AIR, a mixture of 21% oxygen and 79% nitrogen, as a zero reference unless you are certain that no target gas exists in the area. Ambient gas may result in an elevated zero condition that will cause a FAULT to occur once the ambient gas is no longer present. GDS Corp recommends using a span gas that is between 25% and 75% of full scale. GDS Corp does not recommend using full scale as the span set point. Always calibrate a new sensor before depending on the device for personnel or equipment safety Calibrate on a regular schedule. GDS Corp recommends a full calibration every 3 months, with periodic bump tests on a more frequent basis to ensure that the sensor has not been affected by temperature extremes or the presence of incompatible gases. In general, calibration involves applying a zero reference gas and telling the receiving device to accept that output as zero, followed by the application of a span reference gas and then telling the receiving device to accept the new output as span once the output has stabilized. This is generally performed by two persons, one at the sensor transmitter and one at the receiving device. Actual procedures, time intervals and techniques for indicating zero and span values depend on the specific receiving device. All GDS Corp display and alarm controllers provide the necessary local calibration capability. GENERALIZED CALIBRATION PROCEDURE Before beginning calibration, make sure you have the following items: A cylinder of calibration gas, fixed flow regulator and an appropriate calibration cup connected to the regulator via a length of flexible tubing. If necessary, a cylinder of zero air may be necessary if the absence of target gas cannot be confirmed. GDS Corp recommends a flow rate of 0.5 liters / minute. GDS Corp Page 10 info@gdscorp.com

In the case of PID sensors, it may be desired to substitute a surrogate gas for the target gas, especially if the target gas is dangerous or unavailable in a calibration gas cylinder. For more information on surrogate gases and relative response factors for common volatile organic compounds, contact GDS Corp for a list of available gases and response factors. The actual steps involved in calibration vary depending on the receiving device, but can be generalized as follows: 1. Select the appropriate channel on the controller or receiver and enable Calibration Mode. This should disable alarms during the calibration process. Make sure that the controller s Cal Span value matches the cylinder of calibration gas. 2. Apply zero air to the sensor as shown in Fig. 6-1 or confirm the absence of any target gas. 3. At the controller or receiver, press the Set Zero button to confirm that the current reading is zero. 4. Apply span gas to the sensor as shown in Fig 6-1. 5. At the controller or receiver, monitor the output until it stabilizes. When stable, press the Set Span button to confirm that the current reading corresponds to the Span value. 6. Turn off the regulator and remote the calibration cup from the sensor head. 7. At the controller or receiver, exit Cal Mode and resume normal operation. Fixed Flow Regulator Cylinder of Calibration Gas Calibration Cup Figure 5-1: Applying Calibration Gas to GDS-50 GDS Corp Page 11 info@gdscorp.com

6 OPERATION AND MAINTENANCE In the normal operating mode, the 4-20mA output corresponds to the detected gas concentration. In the event of a significant gas release, the GDS-50 will indicate an overrange condition if the sensor s output continues to increase beyond the full scale value. In the event that the sensor output drops below zero due to interference gases or sensor failure, the output will drop to zero, indicating a FAULT condition to the remote receiver or controller. If the sensor is removed, the output will also drop to zero. The GDS-50 should be checked regularly for damage, water ingress or flame arrestor clogging due to excessive dust or dirt. If the flame arrestor has become contaminated by dust, dirt or moisture, remove the sensor head cover (after first making sure to declassify the area) and carefully clean with compressed air. Use of solvent is discouraged as remnants of the solvent material may affect the sensor. There are no user-serviceable components and maintenance is limited to cleaning and/or sensor replacement. Some GDS Corp controllers and gas detectors monitor sensor life by calculating a value between 0 and 100% based on the current response to calibration gas as compared to the initial response when the sensor was first installed. To ensure that the calculations are accurate, please make certain to follow the new sensor installation instructions in the appropriate device manual. SENSOR REPLACEMENT If a sensor shows FAULT, does not respond to gas or can no longer be calibrated, it should be replaced. GDS-50 sensor transmitters use GDS Corp type 10-96XX sensors, where the XX is the gas type shown in Section 3. The range value should also be specified when ordering replacement sensors. For example, a replacement SmartIR infrared for methane, 0-100% LEL would be 10-9650-R0100. To replace a sensor, review Fig. 6-1 and follow these steps: 1. Declassify the area or remove power to the GDS-50. 2. Unscrew the sensor head cover. If unable to open the cover by hand, use a Sensor Head Replacement Tool (p/n 10-0187). 3. Remove the old sensor by pulling straight down. NOTE: PULL STRAIGHT DOWN. DO NOT TRY TO UNSCREW THE SENSOR. 4. Carefully install the replacement sensor by aligning the arrow on the sensor with the arrow engraved on the sensor head. Push straight up until the sensor connector seats firmly into the sensor connector. GDS Corp Page 12 info@gdscorp.com

5. Reinstall the sensor head cover by CAREFULLY screwing the cover onto the sensor head. NOTE: IF THE SENSOR FALLS OUT OF THE SENSOR HEAD DURING THIS STEP, IT CAN BE DAMAGED. USE CAUTION WHEN REINSTALLING THE SENSOR HEAD COVER. Figure 6-1: Sensor Replacement GDS Corp Page 13 info@gdscorp.com

7 SPARE PARTS Enclosure: 12-0099 Enclosure, yellow, solid cover 20-0097 Sensor interface PCB assembly Sensor Head: 10-0247 Stainless steel sensor head Note: Does not include sensor Sensor: 10-96xx GDS Corp SmartIR (V) Sensor Sensor Head Splash Guard 10-0198 Splash Guard (Fits all sensor heads) Sensor Head Flow Cell 10-0205 Flow Cell (1/8 NPT compression fittings) 20-0205S Other (specify) Splash Guard Flow Cell GDS Corp Page 14 info@gdscorp.com

8 DRAWINGS AND DIMENSIONS 4.96 4.5 7.8 Figure 8-1: GDS-50 Dimensions GDS Corp Page 15 info@gdscorp.com