MS-500. User Manual. MS-500 (500g x 0.1g) Copyright 2010 Fast Weigh Scales All rights reserved. Rev. 2.0

Similar documents
BCM-Series. User Manual. American Weigh Scales. BCM-100 (100g x 0.01g) BCM-650 (650g x 0.1g)

AXIS. User Manual. American Weigh Scales. AXIS-100 (100g x 0.01g) AXIS-650 (650g x 0.01g)

CÜBE. User Manual. American Weigh Scales. CUBE-100 (100g x 0.01g) CUBE-650 (650g x 0.1g)

EPSILON. User Manual. EP-5KG (5000g x 1g) Copyright 2011 American Weigh Scales, Inc. All rights reserved. Rev. 1.0

American Weigh Scales, Inc. LB User Manual

American Weigh Scales, Inc. BLADE Series D i g i t a l P o c k e t S c a l e BLADE-550. User Manual BLADE-400 BLADE-1000

All Purpose AP-Series Operation Manual

YAMATO CORPORATION 1775 S. Murray Blvd. Colorado Springs, CO USA Tel (719) Fax (719)

STANDARD OPERATING PROCEDURE

Operating Manual Body fat balance

StockWeigh 500 D3632 US-B

User Manual. Portable Balances PL-E

Troubleshooting Guide: 640 Pediatric Exam Table with Midmark Scale

TABLE OF CONTENTS INTRODUCTION 3 SAFETY PRECAUTIONS 3 PACKAGE CONTENTS 4 DEVICE OVERVIEW 4 BUTTON OPERATION SUMMARY 5 BASIC OPERATION 6

SPS-5. Rate Computing Scale. Operation Manual

ANALYTICAL BALANCE OPERATING MANUAL. U.S. Solid USS-DBS Models All Rights Reserved Page 1 USS-DBS MODELS

OEM Manual MODEL 2305 ECONOMICAL DIGITAL SINGLE CYLINDER SCALE

KERN CM Version /2004

CHM Introductory Laboratory Experiment (r17sd) 1/13

OEM Manual. MODEL ½ Digit DRUM SCALE

SPECIFICATIONS APCEPH1

SAUTER FK Version /2016 GB

How to Achieve Optimal Weighing Performance

Reflow Oven HHL3000 INSTRUCTION MANUAL POHUA - jedyny autoryzowany przedstawiciel w Polsce

KERN EG/EW Version /02

Ambient Weather WS-03 Thermo-Hygrometer

Sensoric 4-20 ma Transmitter Board Operation Manual

Harvard Trip Balance BA710. Impact Test Equipment Ltd & User Guide. User Guide

FOOD INTAKE MONITOR. Hardware and Software User s Manual DOC-047 Rev 3.0. Copyright 2009 All Rights Reserved

CHM 100 / Introductory Laboratory Experiment (r10) 1/11

Sartorius Basic plus Service Manual. WBP5007-e95021

Application Notes. SLP85xD Load Cells

Adam Equipment. DENSITY DETERMINATION KIT for AFP, AAA and AAA/LE SERIES BALANCES OPERATOR S MANUAL

PTG100 Precision Test Gauge

Gilson Aqua-Check Moisture Tester MA-26X

Infrared Ear and Head Thermometer Instruction Manual

BASIC LABORATORY TECHNIQUES (Revised )

User Manual GRI- 1500Li

Manual Weighingblock VB2 series and Uniscale

Eclipse Precision & Analytical Balances

Adam Equipment. DENSITY DETERMINATION KIT for AAA, ADA and ADP SERIES BALANCES OPERATOR S MANUAL

Elcometer ISO Groove Depth Checker. Operating Instructions

Fingertip Pulse Oximeter

NOVALYNX CORPORATION MODEL RAIN GAUGE CALIBRATOR INSTRUCTION MANUAL

Heavy Duty Dissolved Oxygen Meter

MicroTim XB. User Manual. Precision Digital Barometric Altimeter / Barometer / VSI. Document Revision 1.0 Firmware Version 3.0

Precision Liquid Settlement Array Manual

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

Cover Page for Lab Report Group Portion. Pump Performance

TQC Bresle Chloride test 2008

OPERATOR S MANUAL Ar-Gone Weld Gas Analyzer

INSTRUCTION MANUAL. Automatic Blood Pressure Monitor with Fit Cuff. =Fit Cuff=!"#$% IA1B. Model

User Guide. 2 Player Basketball Game

DOscan10 Pocket Dissolved Oxygen Tester Instruction Manual

DT 630 ALTIMETER, BAROMETER AND COMPASS WATCH OPERATING INSTRUSTIONS

Infrared Thermometer Instruction manual

ACCUSTRIDE ACCUSTRIDEFM. Digital Clip-on Pedometer WC153. Digital Clip-on Pedometer WC154 ENGLISH

CONGRATULATIONS ON YOUR PURCHASE OF YOUR THUNDER COMPRESSOR For your personal safety please read, understand and follow the information provided in

Instruction Manual HI 9146 Dissolved Oxygen and Temperature Meter

DO NOT RETURN IT TO THE STORE!

DTG - LCD Digital Temperature Gauge USER MANUAL

444C DUAL PERFORMANCE VALUE PACK

MODEL NUMBER: P-A AUTOMATIC PORTABLE COMPRESSOR

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:

INSTRUCTION MANUAL MANUAL INFLATION BLOOD PRESSURE MONITOR

ActiveYield. Operation and Adjustment

1. Features CONTENTS. English

MILITARY SPECIFICATION POWDER, BLACK

DIGITAL AUTOMATIC TYRE INFLATOR

Short manual testo

Operating Instructions Part No

BOEING AIRCRAFT WEIGH WORKSHEET

IMPORTANT SAFETY INSTRUCTIONS

200 PSI COMPRESSORS - MODEL NUMBERS

100C Air Compressor Kit

Module No GETTING ACQUAINTED GENERAL GUIDE TIMEKEEPING

Lab 1. Instrumentation Familiarity: Using Micropipetters and Serological Pipettes

Altimeter and Compass Watch Instruction Manual

Calibration Gas Instrument INSTRUCTION MANUAL. Release I. Advanced Calibration Designs, Inc.

Service Manual. Sartorius Expert. LE-Models Electronic Analytical and Precision Balances. WLE5001-e04022

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

General Accreditation Guidance. User checks and maintenance of laboratory balances

EC214 EC215 - EC215R Bench Conductivity Meters

Vapor Sorption Analyzer

Misaligned Folds Paper Feed Problems Double Feeds Won t Feed FLYER Won t Run iii

Operating Instructions

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

Ti-Pure TITANIUM DIOXIDE DETERMINATION OF OIL ABSORPTION (OA) METHOD: T WP

Pneumator. Testo Industrial Services More assurance, better service. Pressure calibrator and measuring instrument.

Requirements and Methods for Calibration of Equipment in Clinical Laboratories. NK Chan (HKRCBTS) 24 August 2007

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

II. MATERIALS REQUIRED FOR PERFORMANCE TESTING

Quick Installation Guide Doc nr.: C Date:

This test shall be carried out on all vehicles equipped with open type traction batteries.

English. Quick Guide MS-TS Precision and Analytical Balances

This multi-functional device allows the determination of up to six quality parameters with only one measurement:

BASIC LABORATORY TECHNIQUES (Revised )

SomnoSuite FAQ. Setup. Calibration 4. What are the calibration requirements for the SomnoSuite? Settings

42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only)

Transcription:

User Manual MS-500 (500g x 0.1g) Copyright 2010 Fast Weigh Scales All rights reserved. Rev. 2.0

Thank you for purchasing the Fast Weigh MS-500 digital pocket scale. Please read all operating instructions carefully before use. Scales are precision measuring devices and should always be handled with proper care. To ensure years of reliable service, keep these simple tips in mind: Do not exceed the scale s maximum capacity. Overloading your scale can permanently damage it! Avoid exposure to extreme heat or cold. Scales perform best at normal room temperature. If temperatures have changed dramatically, calibration and adjustment may be necessary. Allow your scale to warm up for 30-60 seconds before performing calibration and adjustment(if available). Store your scale in a clean, dry location. Dust, dirt, and moisture can accumulate on the weighing sensors and electronics causing inaccuracy or malfunction. Avoid using your scale in close proximity to strong radio wave emitting devices such as computers, cash registers, and cordless phones. Always weigh on a flat and level surface, free from vibrations and drafts. The corner of a room is usually the most stable. Gently apply all items to be weighed. Do not drop items onto the weighing platform. Avoid dropping your scale. The warranty does not cover damage due to rough treatment or overload. Check the batteries first if you are having any trouble with your scale. This simple step can remedy most scale issues. Do not disassemble your scale. This product contains no user serviceable parts.

I. Part List 1. Scale 2. Cover / Weighing Tray 3. AAA Batteries (x2) II. Key Description Weight Indicator Mode Key M T ON/OFF Key III. Battery Installation 1. Before using the scale for the first time, check the battery compartment and remove any plastic insulation strips or packaging that may be in place to prevent battery drainage during shipping/storage. 2. If you are replacing the batteries, make sure the positive and negative contacts are properly aligned. AAA AAA

IV. Operation 1. Place the scale on a flat, level surface and press the T key to turn the scale on. 2. Once the start-up process completes and the scale goes to zero you are ready to weigh. 3. Place the quantity to be weighed onto the weighing platform. 4. Wait a couple seconds for the display to stabilize before taking a weight reading. V. Changing the Unit of Measure 1. Press the M key to change the scales displayed unit of measure. 2. If the scale is turned off then back on, it will default to the last unit used. MS-500 Units: g (gram) oz (ounce) ozt (troy ounce) dwt (pennyweight) VI. Using the Tare Feature You can use this scale s tare feature to subtract the weight of an empty container or vessel for net weight determination. NOTE: The weight of the container will subtract from the available capacity. 1. Place the empty container or vessel on the weighing platform. 2. Press the T key once. The display will then reset to zero. If the container is removed, it s weight will be displayed as a negative number. 3. You may now fill the container with the quantity to be weighed. The display will show the net weight of the contents.

VII. 4. To return to normal weight display (gross weight), remove any items from the weighing platform and press the T key again to re-zero the scale. Calibration Calibration and adjustment are performed at the factory. However, the weighing range can shift slightly during shipping. Also, due to changes in local acceleration of gravity around the world, adjustment is recommended when moving the scale from one location to another. To check calibration: VIII. 1. Place the required calibration weight on the scale and note the displayed value. 2. If the displayed value is not within acceptable tolerance (see chart below), adjustment is required. Model Acceptable Calibration Recommended Tolerance (±) Weight Accuracy Class MS-500 0.2g 500g OIML M2 Adjustment 1. Turn the scale OFF. 2. Press and hold the M key then tap the T key to turn the scale on. 3. Release the M key once the display shows a random number (ISN). 4. Tap the T key again. The display will show Zero followed by the required calibration weight. 5. Place the required weight on the center of the platform and press the T once more. 6. The display will show PASS and return to normal

weighing mode. Calibration is complete! IX. Troubleshooting Problem: Scale will not turn on Solution: Check the batteries Problem: Displayed weight fluctuates randomly Solution: Make sure your workspace is stable and free of any air currents or vibration Problem: Displayed weight is inaccurate Solution: Perform a calibration adjustment X. Error Codes 1. OUTZ - Zero range has shifted. Perform calibration adjustment. If the problem persists, the load cell may be permanently damaged due to overloading. 2. UNST - Scale is unstable. Use in a more stable position. 3. HHHHH - Maximum capacity exceeded. Remove the extra weight to avoid damaging the load cell. 4. L - Batteries are low. Replace the batteries.

XI. Specifications MS-500 Max. Capacity 500g Readability 0.1g Min. Weight 0.2g Power 2 x AAA Alkaline Batteries Dimensions 0.8 x 2.4 x 3.5 Platform Dimensions 2.2 x 2.2 Warranty 5 Year Limited Warranty XII. Capacity/Readability Charts MS-500 500g x 0.1g 17.64oz x 0.001oz 16.08ozt x 0.001ozt 321.5dwt x 0.1dwt