INSTALLATION INSTRUCTIONS for the Kodak K-Lab PROCESSOR Service Code: 2044 for Kodachrome FILM, PROCESS K-14M

Similar documents
Installation Instructions

Installation Instructions

BUBBLER CONTROL SYSTEM

Installation Instructions

FX134, FX1234, FX3030 Problem and Solutions

BUBBLER CONTROL SYSTEM

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP

CC Burst Test System

DRS4-RM Manual. Set Up Instructions for DRS4 Series Single Tank

FOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM

Pressure Automated Calibration Equipment

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

24L OIL FREE AIR COMPRESSOR MODEL NO: TIGER 7/250 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS10/13

Accu-Tab Systems 2000 P Series by Axiall Corporation

R E D I C O N T R O L S

Saline C 6.0 Junction Box

Aquavar SOLO 2 Frequently Asked Questions

Accu-Tab Systems 1000 Series by Axiall Corporation

Owners Manual Models: 075-AQF-CX. Aquatrol Backwashing Catalytic Carbon Filter. Visit us online at.

Rejuvenation Instructions

Operation Instruction Manual

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units Digital Range

Gerber Sabre 404 and 408 Installation Instructions

VERTICAL AIR COMPRESSORS

BRILLIANT WONDERS LED BUBBLERS INSTALLATION INSTRUCTIONS & PRODUCT MANUAL CMP SERIES

ABRASIVE SYSTEM ABRASIVE REGULATOR II 800# BULK ABRASIVE DELIVERY POT Abrasive Regulator II and 800# Pot Manual

ECONORESS ELECTRONIC EPS & EPT - ENHANCED PRESSURISATION SET INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

WSN: XXXXXX 101 ROME COURT FORT COLLINS, CO, PHONE #: (970) FAX #: (970) TO-Clean Manual

AUTOMATIC TIRE INFLATOR # MW-60, MW-60-4WAY & MW-64HP

LUDLUM MODEL 239-1F FLOOR MONITOR. Revised December 2010

DPC-30 DPC-100. Reference Manual

INSTRUCTION MANUAL. FLOW CONTROL DRAWERS MANUAL / PLC CONTROL SERIES Model Version Perma Pure LLC Tel:

4 CONTROL-CHART EXAMPLES

SPECIFICATIONS APCEPH1

GASGUARD VENT LINE3 Ammonia Sensor OPERATING & INSTALLATION MANUAL

Armfield Distillation Column Operation Guidelines

100L AIR COMPRESSOR MODEL NO: TIGER 16/1010 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS01/13

J Air and Water Kit Instructions Part# 02584

Digital Vacuum Regulator

User Manual MFCS TM -EZ

In Vessel Composter Installation & Commissioning Manual

Nitrogen Tyre Inflator Owner s Manual

Instructions for Assembly, Installation, and Operation of the Gas Addition Kit Accessory with the CEM Discover Systems

GG-VL2-NH3 AMMONIA VENT LINE SENSOR. Installation and Operation Manual

VERTICAL AIR COMPRESSORS

OPERATION MANUAL NTF-15

D Series Air and Water Kit Part# 02550

OPERATION MANUAL RTI RHS650 RTI TECHNOLOGIES, INC East Market Street York, PA Manual P/N

OPERATION MANUAL NTF-60 Plus

Varian 325-MS LC/MS Quadrupole Mass Spectrometer Pre-installation Instructions

6900 Maintenance Instruction System Flush

AIR COMPRESSOR OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: CHAMP 3 PART NO: LS0115

accidents which arise due to non-observance of these instructions and the safety information herein.

24L AIR COMPRESSOR OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: RANGER 7/240 PART NO: LS0913

PRE-PURCHASE DECISIONS...1 BEFORE DELIVERY...1

24L AIR COMPRESSOR MODEL NO: TIGER 11/250 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS01/13

OPERATION MANUAL BFX-2

Superconducting Susceptometer (MPMS-5S) Quantum Design Room 296 (MPMS)

Duplex Commercial Softeners

Geotech 1.66 Auto-Reclaimer

Geotech 1.66 Auto-Reclaimer Installation and Operation

Hill PHOENIX Second Nature Medium Temperature Secondary Refrigeration Start-Up Guide

Varian 240-MS GC/MS Ion Trap Mass Spectrometer Pre-installation Instructions

Performa Cv Twin Alternating and High Flow Systems. Manual Supplement

AIR COMPRESSOR. Failure to follow all instructions as listed below may result in electrical shock, fire, and/or serious personal injury.

700 SERIES BMS II BUBBLER MONITORING SYSTEM

Light Commercial Reverse Osmosis System. EE-1000 Manual

PumpAgents.com - Click here for Pricing/Ordering Nominal psi (bar) Cut-In Cut-Out

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

Squeegee Unit for MRS Multi-Recovery System

Installation and Instructions 2. Product Features 3-6. Key Pad Functions 7. Distributor Information Programming Guide 8. Master Programming Guide 9-14

Installation, operating and maintenance Instructions for Seemag bypass level indicator

HZ-300 HAZER MACHINE USER MANUAL. Congratulations on the purchase of your new ANTARI HZ-300 Haze Machine.

Information Sheet. About this information sheet. Floor and wall loadings. Attachment of process module to floor. PlasmaPro Estrelas100

Installation, Operation, and Maintenance Manual

ABRASIVE REGULATOR II

AC1810 / AC1810-A TECHNICAL SPECIFICATIONS. Operating Pressure psi ( kgs/cm²) [AC1810] Displacement. Net Weight

200L BELT DRIVEN AIR COMPRESSOR

Calcium Reactor. CalcFeeder PRO. User Manual 1.1a. Model. CalcFeeder AC1 PRO CalcFeeder AC2 PRO CalcFeeder AC3 PRO CalcFeeder AC4 PRO

Precision Hydrogen (All B&W Screen Models)

SC505 Sof Care Inflator. Operating Instructions and Service Manual

MODEL 840 AIR HYDRAULIC PUMP INSTRUCTION

Smart JVA Module WARNING. For use with AquaLink RS systems with rev R firmware or newer.

HumiSys HF High Flow RH Generator

a division of Enviro Safety Products

Installation, Operation and Maintenance Manual

ENVIRONMENTAL INSTRUMENTS, LLC

Part IV: Troubleshooting

BioAerosol Nebulizing Generator. Operation and Maintenance User Manual

Safety instructions and operating manual

Water Mist Systems Inspection, Testing, and Maintenance of Water Mist Systems

Oxford Instruments Plasma Technology. PlasmaPro NGP80. Installation Data Sheet. Original Instructions.

WIDDER TOOLS. HPICAL Calibration Station 1 (203)

Vacuum Model Nitrogen Tyre Inflation System Main Features: PN-8820 Nitrogen Tyre Inflator Operation Steps

System Pressure Manager Standard & System Pressure Manager Plus

Operating Instructions Part No

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

Instruction Manual Recovery Station

INSTRUCTION MANUAL FOR MODEL 7360V VERTICAL CURING CHAMBER Revision E May

Transcription:

Publication No. II2044-1 06APR99 INSTALLATION INSTRUCTIONS for the Kodak K-Lab PROCESSOR Service Code: 2044 for Kodachrome FILM, PROCESS K-14M G128_0703HA GLOBAL CUSTOMER SERVICE AND SUPPORT Eastman Kodak Company

PLEASE NOTE The information contained herein is based on the experience and knowledge relating to the subject matter gained by Eastman Kodak Company prior to publication. No patent license is granted by this information. Eastman Kodak Company reserves the right to change this information without notice, and makes no warranty, express or implied, with respect to this information. Kodak shall not be liable for any loss or damage, including consequential or special damages, resulting from any use of this information, even if loss or damage is caused by Kodak s negligence or other fault. This equipment includes parts and assemblies sensitive to damage from electrostatic discharge. Use caution to prevent damage during all service procedures. Table of Contents Description Page Unpacking the System.................................................... 3 Unpacking the PROCESSOR...................................... 3 Unpacking the REPLENISHER RACK.............................. 9 Unpacking the FILLING STATION and CHILLER AY................. 11 Unpacking the COMPUTER Components............................ 13 Connecting the HOSES................................................... 14 Installing the Parts....................................................... 19 Connecting the Electrical Components....................................... 21 Connecting the Power in the ELECTRICAL CABINETS................ 21 Connecting the COMPUTER Components............................ 22 Connecting the INLINE WATER HEATER........................... 24 50/60 Hz Conversion..................................................... 25 Initial Test for Leakage................................................... 26 PROCESSOR................................................... 26 CHILLER...................................................... 26 Final Test for Leakage................................................... 27 Preparing for Testing............................................. 27 Calibrating the REPLENISHER PUMPS............................. 30 Filling the REPLENISHER LINES.................................. 33 Splicing the LEADER............................................ 36 Finishing Preparations............................................ 37 2 06APR99 II2044-1

Section 1: Unpacking the System Unpacking the System Unpacking the PROCESSOR Important If the Kodak K-Lab PROCESSOR is being installed out of the country, you might need to remove a plywood box from the PROCESSOR, REPLENISHER RACK, and CHILLER AY before doing this procedure. PROCESSOR HOSES 8 LEVELING FEET front G128_0437HCA G128_0437HC [1] Remove and discard the external packing material from the PROCESSOR. [2] Connect the 8 LEVELING FEET to the PROCESSOR. [3] Remove all the HOSES from the inside of the PROCESSOR. II2044-1 06APR99 3

INSTALLATION INSTRUCTIONS HOSES PROCESSOR PALLET front G128_0440HCA G128_0440HC Warning The weight of the PROCESSOR is 910 kg (2000 lbs). Kodak recommends that you use professional RIGGERS to move the equipment. [4] Lift the PROCESSOR from the PALLET. [5] Place all the HOSES over the top of the PROCESSOR to prevent damage while moving. 4 06APR99 II2044-1

Unpacking the System PROCESSOR HOSES G128_0800HCA G128_0800HC [6] Place the PROCESSOR in the permanent location. [7] Level the PROCESSOR. WIRE TIE leader STAPLES WIRE TIE SPLICE BOX ELEVATOR G128_0401HCA G128_0401HC [8] Remove: WIRE TIES from the SPLICE BOX STAPLES from the LEADER WIRE TIE from the ELEVATOR WIRE TIE II2044-1 06APR99 5

INSTALLATION INSTRUCTIONS DRIVE GEAR WIRE TIE DEMAND DRIVE WIRE TIES [9] Remove from all 7 TANKS: WIRE TIE from the TANK 4 WEDGES BLOCK WIRE TIES from each side of the DEMAND DRIVE WIRE TIE from the DRIVE GEAR 4 WEDGES BLOCK WIRE TIE G128_0402GCA G128_0402GC TANK RED REEXPOSURE PRINTER WIRE TIES BLUE REEXPOSURE PRINTER CENTER PACER DRIVE G128_0400BCA G128_0400BA WIRE TIE [10] Remove: WIRE TIES from the RED REEXPOSURE PRINTER WIRE TIES from the BLUE REEXPOSURE PRINTER WIRE TIE from the CENTER PACER DRIVE 6 06APR99 II2044-1

Unpacking the System WIRE TIE [11] Remove: WIRE TIE BOX of miscellaneous parts REM JET G128_0414CCA G128_0414CC BOX of miscellaneous parts II2044-1 06APR99 7

INSTALLATION INSTRUCTIONS 5 FLOATING COVERS TOP PRESSURE ROLLER G128_0424BCA G128_0424BC TOP AIR SQUEEGEES 14 TANK SQUEEGEES LEADER STAPLES PRESSURE ROLLER WIRE TIE [12] Check that the box of miscellaneous parts contains: 5 FLOATING COVERS PRESSURE ROLLER 14 TANK SQUEEGEES 2 AIR SQUEEGEES [13] Remove: WIRE TIES STAPLES TAKE-OFF PACER DRIVE STAPLES G128_0403GCA G128_0403GC 8 06APR99 II2044-1

Unpacking the System Unpacking the REPLENISHER RACK REPLENISHER RACK 4 LEVELING FEET SHIPMENT BANDS G128_0409HCA G128_0409HC PALLET [1] Remove and discard the external packing material from the REPLENISHER RACK. [2] Remove the 5 SHIPMENT BANDS. Warning The weight of the REPLENISHER RACK is 227 kg (500 lbs). [3] Lift the REPLENISHER RACK from the PALLET. II2044-1 06APR99 9

INSTALLATION INSTRUCTIONS DRAIN END G128_0706HCA G128_0706HA Important The DRAIN END must be the lowest point of the REPLENISHER RACK. [4] Place the REPLENISHER RACK in the permanent location. 10 06APR99 II2044-1

Unpacking the FILLING STATION and CHILLER AY FILLING STATION CHILLER AY Unpacking the System [1] Remove and discard the packing material from the FILLING STATION and CHILLER AY. G128_0435GCA G128_0435GC TANK WOOD RAILS [2] Remove the FILLING STATION from the PALLET and set it on the CASTERS. [3] Place the TANK on top of the FILLING STATION using the WOOD RAILS and the 4 SCREWS provided. FILLING STATION CASTERS 4 SCREWS G128_0425GCA G128_0425GC II2044-1 06APR99 11

INSTALLATION INSTRUCTIONS REPLENISHER RACK [4] Unpack the CHILLER AY. [5] Place the CHILLER AY next to REPLENISHER RACK. G128_0416GCA G128_0416GC CHILLER AY 12 06APR99 II2044-1

Unpacking the System Unpacking the COMPUTER Components MONITOR POWER SUPPLY CENTRAL PROCESSING UNIT SPEAKERS DENSITOMETER KEYBOARD G128_4902HCA G128_4902HC [1] Unpack: MONITOR CENTRAL PROCESSING UNIT KEYBOARD POWER SUPPLY DENSITOMETER SPEAKERS II2044-1 06APR99 13

INSTALLATION INSTRUCTIONS Section 2: Connecting the HOSES 100 WATER HOSE 14 REPLENISHER HOSES HOT and COLD WATER HOSES AIR SUPPLY to REGULATOR 85 WATER HOSE AIR HOSE INTELLIFAUCET HOSE G128_5714HCA G128_5714HC [1] Connect: 14 REPLENISHER HOSES 2 WATER HOSES AIR HOSE INTELLIFAUCET HOSE 14 06APR99 II2044-1

Connecting the HOSES REM JET REPLENISHER TM 1.9 cm (3/4 in.) DURABRADE 85 WATER HOSE from INTELLIFAUCET VACUUM SQUEEGEE AIR LINE 1.9 cm (3/4 in.) DRAIN HOSE First DEVELOPER REPLENISHER front 1.9 cm (3/4 in.) DRAIN HOSE Cyan DEVELOPER REPLENISHER 1.9 cm (3/4 in.)chiller IN HOSE from CHILLER OUTPUT 1.9 cm (3/4 in.) CHILLER OUT HOSE to CHILLER INPUTS TM 1.9 cm (3/4 in.) DURABRADE 100 WATER HOSE from INTELLIFAUCET Yellow DEVELOPER REPLENISHER VACUUM SQUEEGEE and BLEACH AIR LINE Magenta DEVELOPER REPLENISHER BLEACH REPLENISHER CONDITIONER REPLENISHER FIXER REPLENISHER FINAL RINSE REPLENISHER 1.9 cm (3/4 in.) DRAIN HOSE G128_0438HCA G128_0438HC [2] Connect the 1.9 cm (3/4 in.) HOSES to the bottom of the PROCESSOR. See the graphic for the correct positions. Note The HOSES must reach the drains. AIR REGULATOR to COMPRESSED AIR AIR SUPPLY HOSE G128_5715HCA G128_5715HC [3] Install a 1.2 cm (1/2 in.) AIR SUPPLY HOSE to the AIR REGULATOR. II2044-1 06APR99 15

INSTALLATION INSTRUCTIONS AIR REGULATOR 25 0 60 G128_0014HC EXHAUST DUCT COLLAR [4] Set the AIR REGULATOR to 25 psi. [5] Route the DRAIN HOSES to the drain. Note The flow for the DRAIN HOSE must not be blocked. [6] Connect the FIXER OUTPUT HOSE to the FIXER OUTPUT. [7] Connect the EXHAUST DUCT to the COLLAR. FIXER OUTPUT FIXER OUTPUT HOSE G128_0417GCA G128_0417GC 3 DRAIN HOSES 16 06APR99 II2044-1

Connecting the HOSES from PROCESSOR [8] Connect the INPUT and OUTPUT HOSES from the PROCESSOR to the CHILLER AY. [9] Route the DRAIN HOSE to the drain. CHILLER AY G128_0418GCA G128_0418GC DRAIN HOSE INPUT/OUTPUT HOSES II2044-1 06APR99 17

INSTALLATION INSTRUCTIONS 18 06APR99 II2044-1

Section 3: Installing the Parts Installing the Parts PRESSURE ROLLER SPLICE BOX G128_0406HCA G128_0406HC [1] Install the PRESSURE ROLLER in the SPLICE BOX. PRESSURE ROLLER BRACKET PROCESSOR ENTRANCE ROLLER G128_0423HCB G128_0423HC [2] Install the PRESSURE ROLLER in the BRACKET for the PROCESSOR ENTRANCE ROLLER. II2044-1 06APR99 19

INSTALLATION INSTRUCTIONS AIR SQUEEGEE G128_0420BCA G128_0420BC 14 TANK SQUEEGEES AIR SQUEEGEE AIR SQUEEGEE 6 7 TOP G128_0432ACA G128_0432AC AIR SQUEEGEE [3] Install the 2 AIR SQUEEGEES and 14 TANK SQUEEGEES. G128_5213GCA G128_5213GA 20 06APR99 II2044-1

Section 4: Connecting the Electrical Components Connecting the Electrical Components Connecting the Power in the ELECTRICAL CABINETS GROUND STUD LINE FILTER G128_0411ACA G128_0411AC MAIN FUSE AY red wire green wire black wire white wire orange wire Important An electrician should make these connections. [1] Check that all the connections are correct in the ELECTRICAL CABINET of the PROCESSOR. Check that: black wire red wire orange wire white wire green wire is connected to: MAIN FUSE AY MAIN FUSE AY MAIN FUSE AY LINE FILTER GROUND STUD [2] Check that the supplied voltage meets the site specifications. LINE FILTER MAIN FUSE AY white wire green wire black wire [3] Check that all the connections are correct in the ELECTRICAL CABINET of the REPLENISHER RACK. Check that: black wire white wire green wire is connected to: MAIN FUSE AY LINE FILTER GROUND STUD [4] Check that the supplied voltage meets the site specifications. [5] Connect the power of the CHILLER AY into the wall OUTLET. G128_0407GCA G128_0407GC GROUND STUD II2044-1 06APR99 21

INSTALLATION INSTRUCTIONS Connecting the COMPUTER Components POWER SUPPLY TOUCH SCREEN CABLE COM 1 MONITOR CABLE SPEAKERS LINE/TEL CO JACK KEYBOARD COMMUNICATIONS CABLE DENSITOMETER TELEPHONE CABLE REPLENISHER RACK PROCESSOR from PROCESSOR to REPLENISHER RACK G128_0408DCA G128_0408DC to COMPUTER [1] Connect the COMPUTER to the PROCESSOR and the REPLENISHER RACK. Connect: From: To: TELEPHONE CABLE PHONE JACK LINE/TEL CO JACK COMMUNICATIONS CABLE CENTRAL PROCESSING UNIT PROCESSOR COMMUNICATIONS CABLE PROCESSOR REPLENISHER RACK TOUCH SCREEN CABLE MONITOR CENTRAL PROCESSING UNIT MONITOR CABLE MONITOR CENTRAL PROCESSING UNIT DENSITOMETER COMMUNICATIONS CABLE DENSITOMETER COM 1 on the CPU 22 06APR99 II2044-1

Connecting the Electrical Components Connect: KEYBOARD MONITOR DENSITOMETER AC POWER CENTRAL PROCESSING UNIT UPS POWER SUPPLY To: CENTRAL PROCESSING UNIT SWITCHED WALL OUTLET SWITCHED WALL OUTLET UPS POWER SUPPLY WALL OUTLET (Do not use the SWITCHED WALL OUTLET). Note Some COMPUTERS have different positions for the connections. If the film breaks, you have 30 seconds to prevent exposure of the film to light. You must de-energize the room lights, MONITOR, and DENSITOMETER within this time. It would be convenient to have a SWITCH RECEPTACLE for the MONITOR and DENSITOMETER next to the room lights SWITCH. II2044-1 06APR99 23

INSTALLATION INSTRUCTIONS Connecting the INLINE WATER HEATER INLINE WATER HEATER TERMINAL BLOCK SCREWS GROUND STUD entrance COVER G128_0430HCA G128_0430HC [1] Remove the COVER from the INLINE WATER HEATER. [2] Route the CABLE through the entrance. Connect: black wire white wire green wire To: TERMINAL BLOCK TERMINAL BLOCK GROUND STUD [3] Tighten the TERMINAL BLOCK SCREWS. [4] Place the COVER on the INLINE WATER HEATER. Note You may have to do this procedure more than once if your hot water supply does not support the PROCESSOR. 24 06APR99 II2044-1

Section 5: 50/60 Hz Conversion 50/60 Hz Conversion CONTROL BOARD 50 Hz JUMPER G128_1705HCA G128_1705HC Note This is for the European, African, and Middle Eastern Regions (EAMER) only. [1] Cut the 50 Hz JUMPER wire on the 3 MOTOR CONTROL BOARDS: DEMAND DRIVE BOARD CENTER POWER BOARD TAKE-OFF PACER BOARD II2044-1 06APR99 25

INSTALLATION INSTRUCTIONS Section 6: Initial Test for Leakage PROCESSOR [1] Fill the TANKS in the PROCESSOR with water. [2] Check the PROCESSOR for leakage. G128_0410ACA G128_0410AC water TANK CHILLER RESERVOIR CAP [1] Remove the COVER. [2] Remove the RESERVOIR CAP. [3] Fill the CHILLER AY with water. water COVER Warning Dangerous Voltage [4] Energize the CHILLER. [5] Add additional water as the air escapes from the CHILLER. [6] Install the RESERVOIR CAP. [7] Check the CHILLER AY for leakage. CHILLER AY G128_0421GCA G128_0421GC 26 06APR99 II2044-1

Section 7: Final Test for Leakage Final Test for Leakage Preparing for Testing CONNECTION TO BIB REPLENISHER RACK G128_4307HCA G128_4307HC REPLENISHER BIBS [1] Connect the REPLENISHER BIBS to the REPLENISHER RACK. [2] Fill the TANKS with water to the top. Warning Dangerous Voltage [3] Energize the PROCESSOR, REPLENISHER RACK and COMPUTER. The PROCESSOR is in the Sleep Mode. G128_0410ACA G128_0410AC water TANK II2044-1 06APR99 27

INSTALLATION INSTRUCTIONS K-LAB Processor Management System Processor Status Replenisher Status Operator Actions OpAlert Log Mode Selection Settings Sleep Mode Status Power Off Operation Sleep Tank Temp. Host Computer Status = IN SLEEP Standby Reexposure Processor Status = IN SLEEP Processing Repl. Rate Replenisher Rack Status = IN SLEEP Calibrate Repl. Rack Pumps Miscellaneous Start PPMS Temp Controller Status = IN SLEEP Reexposure Printers Status = IN SLEEP Change or Refill BIB/Tank KPMS Help Press F1 for Help G128_0007HC Processor Mode SLEEP Processor Status Processing Condition Current Time 12:33:39 PM [4] Select Standby for the Mode Selection. K-LAB Processor Management System Processor Status Replenisher Status Operator Actions OpAlert Log Mode Selection Power Off Settings Operation Entering Standby Mode...please wait Sleep Tank Temp. Host Computer Status = IN STANDBY Standby Reexposure Reexposure Printers Status = CALIBRATING Processing Repl. Rate Processor Status = Calibrate Repl. Rack Pumps Miscellaneous Start PPMS Replenisher Rack Status = Temp Controller Status = Change or Refill BIB/Tank KPMS Help Press F1 for Help G128_0008HC Processor Mode ENTERING STANDBY Processor Status Processing Condition Current Time 1:57:56 PM [5] The above screen displays. 28 06APR99 II2044-1

Final Test for Leakage K-LAB Processor Management System Processor Status Replenisher Status Operator Actions OpAlert Log Mode Selection Settings Standby Mode Status Power Off Operation Sleep Tank Temp. Host Computer Status = IN STANDBY Standby Reexposure Reexposure Printers Status = IN STANDBY Processing Repl. Rate Processor Status = IN STANDBY Calibrate Repl. Rack Pumps Miscellaneous Start PPMS Replenisher Rack Status = IN STANDBY Temp Controller Status = AT SETPOINTS Change or Refill BIB/Tank KPMS Help Press F1 for Help G128_0009HC Processor Mode STANDBY Processor Status Processing Condition Current Time 1:59:28 PM [6] Wait until the PROCESSOR enters the Standby Mode and the above screen displays. G128_0410ACA G128_0410AC water TANK Important The TANK levels will drop when the RECIRCULATION PUMPS are energized. [7] Fill the TANKS to the top with water. [8] Select Change or Refill BIB/Tank. [9] Install the 8 required BIBS on the REPLENISHER RACK. [10] Enter the correct mix codes. [11] Fill the lower TANKS with water. [12] Enter the correct mix codes. [13] Exit Change or Refill BIB/Tank. II2044-1 06APR99 29

INSTALLATION INSTRUCTIONS Calibrating the REPLENISHER PUMPS BUTTON FINAL RINSE RUN RUN CAL CAL VALVE VALVE CALIBRATION HOSE CHILLER AY G128_0429HCA G128_0429HC PUMP [1] Pull the CALIBRATION HOSE for the appropriate PUMP from its storage position. [2] Open the VALVE on the CALIBRATION HOSE. [3] Move the VALVE to the CAL position. [4] Press the BUTTON until air is removed from the CALIBRATION HOSE. [5] Place the CALIBRATION HOSE into a 250 ml GRADUATE. 30 06APR99 II2044-1

Final Test for Leakage K-LAB Processor Management System Processor Status Replenisher Status Operator Actions OpAlert Log Mode Selection Settings Standby Mode Status Power Off Operation Sleep Tank Temp. Host Computer Status = IN STANDBY Standby Reexposure Reexposure Printers Status = IN STANDBY Processing Repl. Rate Processor Status = IN STANDBY Calibrate Repl. Rack Pumps Miscellaneous Start PPMS Replenisher Rack Status = IN STANDBY Temp Controller Status = AT SETPOINTS Change or Refill BIB/Tank KPMS Help Press F1 for Help G128_0009HC Processor Mode STANDBY Processor Status Processing Condition Current Time 1:59:28 PM [6] Select Calibrate Repl Rack Pumps. II2044-1 06APR99 31

INSTALLATION INSTRUCTIONS K-LAB Processor Management System Processor Status Replenisher Status Operator Actions OpAlert Log Mode Selection Power Off Sleep Standby Processing Calibrate Repl. Rack Pumps Change or Refill BIB/Tank Miscellaneous Settings Operation Tank Temp. Reexposure Repl. Rate Start PPMS KPMS Help Replenisher Rack Pump Calibration Select Pump None #1 -Rem Jet Remover #2 -First Developer, Part A #3 -First Developer, Part B #4 -First Developer, Part C #5 -Cyan Developer #6 -Yellow Developer, Part A #7 -Yellow Developer, Part B #8 -Magenta Developer #9 -Bleach #10 -Conditioner #11 -Conditioner Blend Water #12 -Fixer Blend Water #13 -Fixer #14 -Final Rinse Start calibration Use arrows to select chemistry volume (in ml.) and press "Store Volume" 90 Store Volume Exit pump calibration Press F1 for Help G128_0010HC Processor Mode Processor Status Processing Condition Current Time SLEEP 01:10:12 PM [7] Select the correct PUMP. [8] Select Start calibration. A COUNTER appears. [9] When the COUNTER reaches 0, close the VALVE. [10] Place the CALIBRATION HOSE into the storage position. [11] Move the VALVE to the RUN position. Caution The measurement for this calibration must be correct. [12] Enter the measured calibration using the and BUTTONS. Note If the Volume is not 90, do the calibration again until the Volume is 90. [13] Select Store Volume. [14] Repeat this procedure for the remaining PUMPS. [15] Select Exit pump calibration. The PROCESSOR is in Standby Mode. 32 06APR99 II2044-1

Final Test for Leakage Filling the REPLENISHER LINES The purpose of this procedure is to fill the REPLENISHER LINES with fresh chemistry. tape FILM SENSOR G128_0423HCC G128_0423HC CENTER PACER DRIVE [1] Block the FILM SENSOR with tape. [2] Remove the LEADER from the CENTER PACER DRIVE. LEADER G128_0433ACA G128_0433AC II2044-1 06APR99 33

INSTALLATION INSTRUCTIONS TAKE-OFF PACER DRIVE [3] Remove the LEADER from the TAKE-OFF PACER DRIVE. G128_0431ACA G128_0431AC leader K-LAB Processor Management System Processor Status Replenisher Status Operator Actions OpAlert Log Mode Selection Settings Standby Mode Status Power Off Operation Sleep Tank Temp. Host Computer Status = IN STANDBY Standby Reexposure Reexposure Printers Status = IN STANDBY Processing Repl. Rate Processor Status = IN STANDBY Calibrate Repl. Rack Pumps Miscellaneous Start PPMS Replenisher Rack Status = IN STANDBY Temp Controller Status = AT SETPOINTS Change or Refill BIB/Tank KPMS Help Press F1 for Help G128_0009HC Processor Mode STANDBY Processor Status Processing Condition Current Time 1:59:28 PM [4] Select Processing for the Mode Selection. 34 06APR99 II2044-1

Final Test for Leakage K-LAB Processor Management System Processor Status Replenisher Status Operator Actions OpAlert Log Mode Selection Settings Processing Mode Status Power Off Operation Sleep Tank Temp. Host Computer Status = PROCESSING Standby Reexposure Processor Status = PROCESSING Processing Repl. Rate Replenisher Rack Status = PROCESSING Calibrate Repl. Rack Pumps Miscellaneous Start PPMS Temp Controller Status = AT SETPOINTS Reexposure Printers Status = PROCESSING Change or Refill BIB/Tank KPMS Help Press F1 for Help G128_0012HC Processor Mode PROCESSING Processor Status RUNNING K25/40/64 Processing Condition NORMAL Current Time 2:00:50 PM [5] The above screen displays. [6] Check the PROCESSOR and REPLENISHER RACK for leakage. Note Calibration should continue until the REPLENISHER LINES are full. The small PUMPS replenish at a small rate. It might be necessary to use the green BUTTONS to complete filling the REPLENISHER LINES for the small PUMPS. II2044-1 06APR99 35

INSTALLATION INSTRUCTIONS Splicing the LEADER [1] Pull the supply LEADER through the SPLICE CABINET. [2] Route the LEADER as shown in the graphic. [3] Use STAPLES to keep the LEADER together. SPLICE CABINET STAPLES G128_0413ACA G128_0413AC 12.7 mm (0.5 in.) maximum 36 06APR99 II2044-1

Final Test for Leakage Finishing Preparations K-LAB Processor Management System Processor Status Replenisher Status Operator Actions OpAlert Log Mode Selection Settings Sleep Mode Status Power Off Operation Sleep Tank Temp. Host Computer Status = IN SLEEP Standby Reexposure Processor Status = IN SLEEP Processing Repl. Rate Replenisher Rack Status = IN SLEEP Calibrate Repl. Rack Pumps Miscellaneous Start PPMS Temp Controller Status = IN SLEEP Reexposure Printers Status = IN SLEEP Change or Refill BIB/Tank KPMS Help Press F1 for Help G128_0007HC Processor Mode SLEEP Processor Status Processing Condition Current Time 12:33:39 PM [1] Select Standby for the Mode Selection. K-LAB Processor Management System Processor Status Replenisher Status Operator Actions OpAlert Log Mode Selection Power Off Settings Operation Entering Standby Mode...please wait Sleep Tank Temp. Host Computer Status = IN STANDBY Standby Reexposure Reexposure Printers Status = CALIBRATING Processing Repl. Rate Processor Status = Calibrate Repl. Rack Pumps Miscellaneous Start PPMS Replenisher Rack Status = Temp Controller Status = Change or Refill BIB/Tank KPMS Help Press F1 for Help G128_0008HC Processor Mode ENTERING STANDBY Processor Status Processing Condition Current Time 1:57:56 PM [2] The above screen displays. [3] Wait until the PROCESSOR enters the Standby Mode. II2044-1 06APR99 37

INSTALLATION INSTRUCTIONS K-LAB Processor Management System Processor Status Replenisher Status Operator Actions OpAlert Log Mode Selection Settings Standby Mode Status Power Off Operation Sleep Tank Temp. Host Computer Status = IN STANDBY Standby Reexposure Reexposure Printers Status = IN STANDBY Processing Repl. Rate Processor Status = IN STANDBY Calibrate Repl. Rack Pumps Miscellaneous Start PPMS Replenisher Rack Status = IN STANDBY Temp Controller Status = AT SETPOINTS Change or Refill BIB/Tank KPMS Help Press F1 for Help G128_0009HC Processor Mode STANDBY Processor Status Processing Condition Current Time 1:59:28 PM [4] Select Processing for the Mode Selection. 38 06APR99 II2044-1

Final Test for Leakage K-LAB Processor Management System Processor Status Replenisher Status Operator Actions OpAlert Log Mode Selection Settings Processing Mode Status Power Off Operation Sleep Tank Temp. Host Computer Status = PROCESSING Standby Reexposure Processor Status = PROCESSING Processing Repl. Rate Replenisher Rack Status = PROCESSING Calibrate Repl. Rack Pumps Miscellaneous Start PPMS Temp Controller Status = AT SETPOINTS Reexposure Printers Status = PROCESSING Change or Refill BIB/Tank KPMS Help Press F1 for Help G128_0012HC Processor Mode PROCESSING Processor Status RUNNING K25/40/64 Processing Condition NORMAL Current Time 2:00:50 PM [5] Do the following tests: Procedure Check Speed of the CENTER PACER DRIVE Check Speed of the TAKE-OFF PACER DRIVE Check the Film Tension. Adjusting the DEMAND DRIVE ROLLERS Check the Temperature Calibration Calibration Offset Adjustment Check the Re-exposure Calibration [6] Inspect the film for scratches and edge damage. Publication ADJUSTMENTS AND REPLACEMENTS ADJUSTMENTS AND REPLACEMENTS ADJUSTMENTS AND REPLACEMENTS, DIAGNOSTICS OPERATOR S MANUAL II2044-1 06APR99 39

Kodak, K-Lab, and Kodachrome are trademarks. ii2044_1_06apr99.f m GLOBAL CUSTOMER SERVICE AND SUPPORT EASTMAN KODAK COMPANY ROCHESTER, N.Y. 14650