Hydraulic Training Systems

Similar documents
Hydraulic Training Systems

Hydraulic Training Systems

Introduction. Part one: Identify the Hydraulic Trainer Components

Lesson 6: Flow Control Valves

Exercise 2-3. Flow Rate and Velocity EXERCISE OBJECTIVE C C C

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL OTHER FLUID POWER VALVES. This work covers part of outcome 2 of the Edexcel standard module:

PTS1120TSJB PTS2120TSTSJB

Tech Tips. Service Call: Adjustable Hydraulic Valves Flow controls Pressure controls Sequence valves Holding valves

Basic Pneumatics. Module 8: Pressure control valves. Academic Services PREPARED BY. April 2012

Lecture 19 PRESSURE-CONTROL VALVES [CONTINUED]

TRAINING SCHEDULE FLUID POWER TRAINING CUSTOM TRAINING PRODUCT TRAINING

Copyright, 2005 GPM Hydraulic Consulting, Inc.

L125 SERIES POST-COMPENSATED SECTIONAL LOAD SENSE VALVE

American made since 1954

The University of Jordan. School of Engineering. Mechatronics Engineering Department

LV LOADER DIRECTIONAL CONTROL VALVES INSTALLATION & USER GUIDE

Simplified Digital Hydraulic Testers Operating Manual. Oil Solutions. DHC DHT HP

Hydraulics. Hydraulic Pressure Control

Document How to Set Single Stage Press Pressures

Priority (Swing) Motors Data and Specifications

Full Range Pressure Compensating Variable Flow Control

(Refer Slide Time: 0:26)

Basic Hydraulics. Module 4: Flow Control Valves & Pressure Relief Valves. Academic Services PREPARED BY. January 2012

Time-Delay Electropneumatic Applications

WORKHOLDING APPLICATION BOOKLET

Chapter 10: Bidirectional Flow Controls

Introduction to Pneumatics

Model 130M Pneumatic Controller

DBML-60/80 Squeeze Tool

Basic Pneumatics. Module 7: Time delay valve and sequence control systems. Academic Services PREPARED BY. January 2013

SPECIFICATIONS ATTENTION

Interface Devices, Inc. Hydraulic Mini Mule

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10

Unit 24: Applications of Pneumatics and Hydraulics

Proper Pump Installation Practices

Electro-Proportional Valves. Selection Guide HYDRA FORCE

Digital Hydraulic Multimeters

Safe hydraulics for hydroforming presses. more finished product to be created from less raw material.

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

MDC Series. Marine Grade 4-Way Directional Control Valve With Or Without Flow Control MDCF16TH304H MDC16TH404HB

G7S Hand Pump Owner s Manual

Directional Controls

Load Controls Screw In Cartridge Valves Pressures to 350 bar (5000 psi) Flows to 190 l/min (50 USgpm)

Xpress L90LS Directional Control Valve. Catalog HY /UK December, 2001

PVK OPEN LOOP PUMPS. Bulletin E

Installation and Service Manual

SDM to 8 sections monoblock valve D1WWDA02A

BUBBLER CONTROL SYSTEM

PVV Open Loop Pumps. Bulletin E

AutoDrill s OUTSTANDING FEATURES

Vickers. Flow Controls. Flow Controls FN, F(C)G, FRG. Released 6/94

Proportional Pressure-Relief Cartridge Valve, Size 2...4

Directional Controls

Contents. Catalog HY /US Load and Motor Control Valves SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI

Industrial Pneumatics

1 LS unloading (control valve, orifice, none) 2 LS max pressure relief. 3 Spool type

Inverse Prop. Pressure-Relief Cart., Size 2 4

Circuit building blocks

ATL R/V Atlantis AUXILIARY PLANT OPERATION APPENDIX OPERATING PROCEDURES

IFP C175-* REMOTE CONTROL RELIEF VALVE

HPB25 Hydraulic Paving Breaker

DUAL 444C ONBOARD AIR SYSTEM

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP

Section 4: Sequence valve adjustments

Pressure Dump Valve Service Kit for Series 2300 Units

Leak free Pipe Rupture Valve for Excavators

STAND ALONE SPREADER INSTALLATION INSTRUCTIONS AND OPERATOR S MANUAL

To plot the following performance characteristics; A pump is a device, which lifts water from a lower level to a higher

Displacement 12, , Maximum flow rate (at 1450 rpm) bar.

Marschalk Model # 94000

Basic Pneumatics. Module 2: Direct Control of single acting cylinder PREPARED BY. IAT Curriculum Unit. January 2011

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

WARNING: READ THE GENERAL INFORMATION MANUAL INCLUDED FOR OPERATING AND SAFETY PRECAUTIONS AND OTHER IMPORTANT INFORMATION.

Logic Elements Screw-in Cartridge Valves Pressures to 290 bar (4200 psi) Flows to 303 l/min (80 USgpm)

PVQ 13 A2 R SE 1 S 20 C-11 D

Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW. Tel +44 (0)

PRESSURE ADJUSTMENT Main pressure adjustment

MADILL 24.7" 365 TILT SET-UP PROCEDURE WITH REXROTH VALVE ON MACHINE

[You may download this article at: ]

Inverse Proportional Pressure-Relief Cartridge, Size 10

Calera Fire Department Breathing Air System Technical Specifications

BERMAD Waterworks. Level Control Valve with Altitude Pilot. 700 Series. Model X. Features and Benefits. Major Additional Features

Index Table. Model 794. Installation, Operating and Maintenance Instructions

DuPage County Environmental, Safety, Health & Property Loss Control Program Hazardous Energy Control (Lockout/Tagout)

A4s Operation Manual

Target Cleanliness Worksheet. Systemic Contamination Control

Basic Pneumatics. Module 9: Time delay valve. Academic Services PREPARED BY. April 2012

Learning System for Automation and Communications. Hydraulics. Workbook Basic Level

200 PSI COMPRESSORS - MODEL NUMBERS

Dimensions [All numbers in brackets are in millimeters.] K4-2 US (supplied) 1/2" Centered (Default)

General maintenance engineering applications

100C Air Compressor Kit

JLG Models 1200SJP 1350SJP Service and Maintenance Manual P/N PDF download

Technical Data Sheet TI-F50 Locking Units series KFH

INDIAN INSTITUTE OF TECHNOLOGY KHARAGPUR NPTEL ONLINE CERTIFICATION COURSE. On Industrial Automation and Control

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL ACCUMULATORS. This work covers part of outcome 2 of the Edexcel standard module:

BUBBLER CONTROL SYSTEM

Phuel Portable Control Units

42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only)

Cover headline. Cover subheadline. Check Valves

Transcription:

MF102-H-TS Training System - The Model 102-H-TS has the same features and capabilities as the models MF102-H and MF102-H-TSE. The letters TS denote troubleshooting. The only difference between the TS and TSE models is that the TS model has manually operated fault switches and the TSE model has electronically controlled fault switches. Model MF102D-H-TS shown with power unit & hose caddy in swing-out position The TSE model is equipped with an on-board panel PC and a 19 (48cm) touchscreen. The MF102 series training systems are FPTI s flagship models and are undoubtedly our best-selling products. Over a decade of research - FPTI s founder and chief designer is not only a legendary teacher, but he is also one of the most respected hydraulic diagnostics technicians in the country. His contribution to safe and effective troubleshooting is remarkable: He conducted a ten-year study of leakage rates in hydraulic components. He developed a technique that makes it possible to test over 95% of the components in any hydraulic system with the power unit safely locked out. There is no need to remove or disassemble the components, and each test averages 15 minutes. He wrote a best practices manual on safe techniques for testing hydraulic components. He is aware of the critical shortage of hydraulic diagnostic technicians the USA, and indeed the world, faces. In collaboration with industry and education FPTI developed a much-needed solution - It took FPTI over ten years to develop the most effective hydraulic training system on the planet. In the hands of a properly trained teacher the model MF102-H-TS training system has the power to turn ordinary technicians into extraordinary hydraulic technicians because they will have the skillsets needed to revolutionize the industry. Here are just a few of the MF102-H-TS s most outstanding and exclusive features: Safety the MF102-H-TS is equipped with the same lockout system used in industry. It also has FPTI s exclusive Safe-T-Bleed system for de-energizing and air-bleeding hydraulic systems and components. Almost every page in the brilliant textbooks, every Power- Point slide, and every trip to the training system is designed to remind students of their most important responsibility safety.

Load-cycle capable At the push of a lever the cylinder lifts an onboard load into the air, and the bi-directional hydraulic motor has infinitely variable torque capability for a realistic training and troubleshooting experience. Pressure/leak Testing this revolutionary technique, developed by FPTI, will teach students how to test 95% of the components in a hydraulic system with the power unit safely locked out. There is no need to remove or disassemble components, and each test averages 10 to 15 minutes. Quite frankly, there is no other way to test these components. Toggle switch fault insertion activating a toggle switch makes it possible for almost every component on the MF102-H-TS to automatically wear out. FPTI studied wear patterns in hydraulic components for a decade and designed the identical wear patterns into the components on the training system. Student-driven troubleshooting activities Usually when fault switches are manually operated the switches are concealed and the teacher will tell the students to disappear while a fault is being introduced. Not always fair to the teacher because students tend to chat with other students, and it leaves the teacher chasing from one simulator to another to install and remove faults. To keep the student s minds on the topic and avoid undue stress on the teacher, FPTI put the seventeen (17) numbered fault switches in clear sight, and made it so the switches are out of synchronization with one another. When a student is given a troubleshooting activity he/she simply activates the specified switches and proceeds with the activity. Upon completion of the activity the student records which component(s) was defective and then resets the switches for the next activity. Masterfully develops thinking skills the single most important skill technicians must learn is to think. The MF102-H-TS teaches this skill masterfully. When a student is given an assignment, timely and satisfactory completion of the task is determined by how much thinking the student applies to the problem. The student starts out with a chief complaint and one, or more symptoms: identical to a real world situation. The training system activities are designed to let students practice what they are taught about theory, protocols, and practical demonstrations performed by their teachers. In no time at all you will have your students challenging each other as to who can troubleshoot a problem in the least amount of time, with the least number of attempts, and having replaced the least number of components: Isn t that exactly what industry is crying for? Learn in real time on real systems You can achieve a level of training on the MF102-H-TS that s almost impossible to achieve on an actual machine: if, for no other reason than safety. You can give the student a copy of the hydraulic schematic for any type of machine. Then, while it s operating in real time under actual load cycles, the students can learn to troubleshoot it in the safety and comfort of the classroom.

Teach any type of system or component - Fixed displacement pump - standard Pressure-compensated pump standard Load-sensing pump optional Students advance from fixed displacement pump circuits, to pressure-compensated pump circuits, and, if the curriculum permits, load-sensing circuits, on one training system. Six directional control valves - Three (3) industrial-type (parallel) One (1) industrial-type (series) One (1) mobile-type (cylinder spool center) One (1) mobile-type (motor spool center) Why this feature is important: The most logical learning path for a student is to begin with fixed displacement pumps, and then advance to pressure-compensated pumps and then to loadsensing pumps. The MF102-H-TS training system provides instructors the opportunity to teach all of these popular systems. Why these features are important: Students graduate from learning simple, single-valve/ single actuator, circuits to constructing the types of circuits they will see in any plant or on any construction machine. There is almost no limit to the number and variety of circuits students can construct on the MF102-H-TS training system. The MF102-H-TS A winner that begets winners When well-trained technicians can troubleshoot hydraulic systems safely, effectively, and time efficiently everyone wins. Unprecedented student retention - MF102-H-TS training system achieves the highest student retention of any hydraulic training system currently available bar none! Hardware in perfect harmony with the software - The MF102-H-TS training system works in perfect harmony with the equally as well engineered curriculum, visual aids, textbooks, PowerPoint presentations, animations, and support. Why does our course teach pressure control valves before pumps? Because a pressure compensator is a pressure relief valve. Why does it teach flow control valves before load sensing systems? Because the flow compensator in a load-sensing pump is a pressurecompensated flow control valve. The technicians win because they are safe, productive and proud. Their company wins because problems are solved safely, efficiently and cost effectively. Teachers win because they provided students with the tools they needed to become brilliant technicians. And finally, schools win because they fulfilled their responsibility to the teachers, students, industry, and society.

Port identification consistent with industry standards - It is absolutely critical that students learn how important it is to make proper transmission line connections when installing hydraulic components or reconnecting transmission lines. An error can result in severe injury or death. Component manufacturers typically use letters and/or numbers for port identification. All components on FPTI training systems are marked with the appropriate identification. Also, all hydraulic schematics in the student activities manuals show the appropriate markings. Not just a training simulator, an entire turnkey training system - Not only do you get the most advanced hydraulic training simulator in the world, you also get everything you need to conduct a world-class course: Textbooks - written and produced by one of the most successful and renowned hydraulics instructors in the industry - FPTI s founder Rory S. McLaren. Every topic is to the point and safety-based. Student workbooks - well written and superbly illustrated with need-to-know information. PowerPoint -based CD s covering at least 40 hours of instruction in hydraulics and another 40 hours of advanced diagnostics. Instructor answer books. Interactive CD - makes teaching and learning hydraulic symbols fun and challenging. Everything you need to conduct a world-class course is included It s limits? - Your imagination - Teach any pump/system fixed displacement, pressure compensated, load-sensing. Teach any type of component - even the one s it doesn t have with the optional Flex-Plate modules. Simply fasten your unique component to a universal mounting plate (available from FPTI ) and when needed clip it on the FlexPlate - no hardware needed. There is also a convenient 24VDC power supply and illuminated on/off switch for electric valves. Many of the add-on valves are available - readyto-use - from FPTI. See the entire assortment at: www.fluidpowertrainingsystems.com If you don t see what you are looking for on our website let us know and we will build it for you - ready to use. Flex-Plate modules expand the capability of your MF102 series training system Plug-and-Play modules give the MF102 series unlimited training flexibility - Want to teach mobile directional control valves; proportional direction/flow control valves; stacked valves; orbitrol steeringsystems; logic valves; etc? Simply purchase an affordable plug-and-play module, which easily attaches to either side of the MF102 series simulator. The modules are designed to integrate seamlessly with the components on any model MF102 Most plug-and-play modules are available with diagnostics capability.

Specifications (Model MF102-H-TS) - The model MF102-H-TS training systems are equipped with the following components: 1. Pump - Axial piston-type, variable volume, pressure-compensated; 3.78 Lpm (1.0 GPM); 69 bar (1000 PSI); adjustable pressure compensator; adjustable flow 2. Electric motor - Single-phase; 115V; TEFC; 1750 RPM; C-face; thermal overload protection 3. Electric motor on/off switch - Lockout/tagout mechanism; thermal overload protection with manual reset 4. Hydraulic reservoir - capacity 17 liter (4.5 gallon) 5. Filtration - 10 micron, spin on/off element w/bypass gauge 6. Directional control valves - six (6) total; One (1) DO3-type; tandem-center; 3-position; 4-way; spring-centered; solenoid-controlled; 24V coils. Also includes sandwich-mounted, knob-adjustable pump port flow control valve Two (2) DO3-type; closed-center; 3-position; 4-way; spring-centered; solenoid-controlled; 24V coils. Also includes sandwich-mounted, dual, knob-adjustable flow control valves One (1) DO3-type; float-center; 3-position; 4-way; spring-centered; solenoid-controlled; 24V coils. Also includes sandwich-mounted, knob-adjustable pump port flow control valve One (1) Monoblock type valve; cylinder spool; 3-position; 4-way; spring-centered; hand-lever operated w/pressure relief valve One (1) Monoblock type valve; motor spool; 3-position; 4-way; spring-centered; hand-lever operated w/pressure relief valve 7. Pilot-operated pressure relief valve w/knob adjustment 8. Direct-operated pressure relief valve w/knob adjustment 9. Sequence valve w/knob adjustment 10. Pressure reducing valve w/knob adjustment 11. Counterbalance valve with internal reverse flow check w/knob adjustment 12. Needle valve w/knob adjustment 13. Flow control valve w/knob adjustment 14. Pressure-compensated flow control valve restrictor-type; reverse flow bypass; w/knob adjustment 15. Check valve 16. Pilot-operated check valve w/manual over ride 17. Cylinder - single-rod; double-acting; 36 cm (14 ) stroke 18. Cylinder - double-rod; double-acting; 36 cm (14 ) stroke; w/load engage/disengage mechanism 19. Motor - bi-directional; gear-type; w/infinitely variable torque capability 20. Flow meters - two (2); 7.56 Lpm (0-2.0 GPM) 21. Tachometer - digital-type; panel-mount; hydraulic motor shaft speed 22. Ammeter - analog-type, panel-mount 23. Dual scale temperature gauge - digital-type; panel-mount; upper: oil temperature; lower: ambient temperature 24. Stopwatch - digital, self-retractable 25. Pressure gauges - three (3); 103 bar (0-1500 PSI); PSI and bar scales; 6.35 cm (2.5 ); glycerine-filled; Bourdon tube type; w/flat-face type quick-connect/disconnect type valves 26. Load - 45 Kg (100 lb); Engage/disengage with mechanical latch. Entire weight is contained within a transparent safety enclosure. 27. Hose storage caddy - stow-away/swing-out 28. Hoses (per side) - Four (4) - 152 cm (60 ) Eight (8) - 107 cm (42 ) Six (6) - 71 cm (28 ) SAE 100-R1; w/flat-face type quick-connect/ disconnect type valves 29. T s - eight (8) (per side) w/flat-face type quick-connect/disconnect type valves

Shipping Specifications - Shipping weight (does not include pallet or packaging): Double unit: 408 kgs (900 lbs) Single unit: 340 kgs (750 lbs) Warranty - FPTI warrantees it s products against defect in materials or workmanship for a period of two (2) years from date of delivery. Shipping dimensions (all models): 196 cm (77.0 ) tall x 122 cm (48.0 ) wide x 76 cm (30.0 ) deep All FPTI training systems are available for operation at any voltage or frequency MF102-H-TS (03/13/13) COPYRIGHT 2013