Halsey Taylor Owners Manual

Similar documents
Halsey Taylor Owners Manual

SWIRLFLO Refrigerated fountains with FLEXI-GUARD

Installation/Care/Use Manual Soft Sides Fountains with FLEXI-GUARD

Halsey Taylor Owners Manual

Owners Manual. Models 4420BF1U & 4420BF1L Floor Mounted Bi-Level Bottle Filler Tubular Fountain

Halsey Taylor Owners Manual STOP!

Halsey Taylor Owners Manual 4410 Freeze Resistant Tubular Fountain STOP!

Owners Manual Models 4430BF3, 4430BF2 & 4430BF1 Floor Mounted Tri-Level Bottle Filling Tubular Fountain

Installation and Use Manual

PAGE (Rev. A - 06/17)

INSTALLATION, CARE & USE MANUAL. EMASMB & LMASMB Surface Mount Bottle Filling Stations

Installation/Care/Use Manual

Installation Instructions

Installation Instructions

INSTALLATION INSTRUCTIONS FOR GRT75-PF-RFS PET FOUNTAIN

INSTALLATION INSTRUCTIONS

BASIN AND WALL MIXER INSTALLATION INSTRUCTIONS

LK4420BFFR - FTN, 4420BFFR - FTN. Owners Manual

Pressure Dump Valve Service Kit for Series 3000 Units

Anderson Greenwood Series 93 Positive Pressure POSRV Installation and Maintenance Instructions

VOLUMATIC WATER REGULATOR

Installation Instructions

Pressure Dump Valve Service Kit for Series 2300 Units

SUMMITTM 400 & 600. Natural Gas Barbecues. Step-By-Step Guide

Booster Pump PB4-60 Replacement Kits

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual

UltRo Dual Flow Reverse Osmosis Water System

INSTALLATION INSTRUCTIONS 1/2 THERMOSTATIC VALVE AND TRIM

Installation Troubleshooting Maintenance Instructions Installation / Start-up

Engineering Excellence. Installation Guide

Final Assembly Instructions Bikes with 16 Wheel Size

DS05C,D,G Dial Set Pressure Regulating Valves

Service and Repair Manual

Santa Fe Cycles Assembly Guide Introduction

V46 Series 2-Way Pressure-Actuated Water-Regulating Valves With Union Fittings

D05 Pressure Regulating Valves

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

Aquor House Hydrant V2

Contents. Stainless Steel Side Block. 1.1 Separating the Side Block. Stainless Steel Side Block Reassembly of. Assembly from the Helmet Shell

ETL listed for installations within 5 ft. (1.5M) of outer edge of water

UNITY 2. Uni-DAAMS Manual. Version 1.3 (Changes to Section 1.1) March 2010

INSTALLATION INSTRUCTIONS

Multi-Probe Sampling System User Guide & Manual

TECHNICAL DATA CAUTION

V48 Series 3-Way Pressure-Actuated Water-Regulating Valves With Union Fittings

BP48-1 AND SSP48-1 IN-GROUND POST INSTALLATION INSTRUCTIONS

BPB26-1 AND SSPB26-1 PATIO BASE INSTALLATION INSTRUCTIONS

REVERSE OSMOSIS WATER FILTRATION SYSTEM MODEL EWR 4075 INSTRUCTION MANUAL

PART NUMBER: E361SXA200 DESCRIPTION: KAYAK CARRIER

LRS(H)4 Pressure-Reducing Regulator User Manual

Anti-flood device Model B-1

TECHNICAL DATA. Page 1 of 12

MUELLER. A Wall Type. Indicator Post. Reliable Connections. General Information 2. Technical Data/ Dimensions 3. Installation 4-5.

Agilent 1290 Infinity Pump Head Maintenance

MMR Air Mask With. with Quick-Connect Hose

D05T Compact Design Pressure Regulating Valves

Latvin Luxury Shower Panel. Telephone Product Specification. ~ Minimum Working Pressure 1.0 bar ~ Maximum Working Pressure 3.

Model VR6 System. Installation, Operation & Maintenance

MUELLER A A Non-Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.

COMPACT TRIPLE WALL OUTLET STATION MODEL INSTALLATION AND OPERATING INSTRUCTIONS

Operation Manual Piston Sensed Gas Pressure Regulators

CO2 Tank Conversion Kit P.N , P.N , and P.N

!!!! SERVICE MANUAL PRESSURE POT 2 GALLON. Service Manual: LT Washington St 931 Progress Ave., #7

TECHNICAL DATA. Pressure Regulation 531a. April 24, 2009

Speed control assembly model A-1

INSTRUCTION MANUAL. January 23, 2003, Revision 0

RD(H)20/25 Pressure-Reducing Regulator User Manual

Final Assembly Instructions Bikes with Threaded Headsets

book : t95575.fm Seite 1 Mittwoch, September 20, :10 AM. Avensys. Exposed Single Lever Mixer

Anderson Greenwood Series 400 Diaphragm Pilot Operated Safety Relief Valves. Installation and Maintenance Instructions for

HPIC D Hydrostatic Test Pump PRODUCT INFORMATION AND OPERATING INSTRUCTIONS

MUELLER. A A Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.

299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012

FOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM

INSTALLATION INSTRUCTIONS

bathrooms.com Concentric Thermostatic Shower Mixers Cleaning and Care Installation Manual Contents

Syringe, Distribution Valve and Infusion Pump Removal/Replacement ATTENTION SYRINGE REPLACEMENT

Medical Gas Control Panel

Assembly Drawing: W-311B-A01, or as applicable Parts List: W-311B-A01-1, or as applicable Special Tools: , , &

INSTALLATION & MAINTENANCE INSTRUCTION

INSTALLATION and OPERATION INSTRUCTIONS

Thank you for purchasing your new Empire Reloader B Sound-Activated 3-Speed Paintball Hopper!

SERVICE MANUAL SALAMANDER BROILERS RADIANT AND INFRARED 36RB 36IRB VULCAN C36RB C36IRB WOLF

INSTALLATION GUIDELINES

RG1200 Service and Repair Manual

INSTALLATION GUIDELINES

SLIPPER & ROLL-TOP FREESTANDING BATHS

Floor Drinking Systems

Carter Option X Valve connector assembly. Maintenance manual

MUELLER. Mega-Lite Drilling Machine. Reliable Connections. table of contents PAGE. Equipment 2. Operating Instructions 3-4. Parts Information 5

2.5 & 5.0 GALLON PRESSURE TANKS

Constant Pressure Crude Oil Container Model CPCCP

830 SureFlo Soap Systems Installation Instructions. Foam Soap Cabinet... Pages 2-9 Liquid Soap Cabinet... Pages 10-19

3.5 litr es per INSTALLATION INSTRUCTIONS. Avon 21 Self-closing taps (Push button) B0992AA Self-closing basin pillar tap

Type S301 & S302 Gas Regulators INTRODUCTION INSTALLATION. Scope of Manual. Description. Specifications. Type S301 and S302. Instruction Manual

DL 8 Dome Port. Product Registration. Product Number 75340

TECHNICAL DATA ANTI-FLOOD DEVICE MODEL B-1 1. DESCRIPTION

Wafer Check Valve. Contents. User s Manual. (1) Be sure to read the following description of our product warranty 1

INTRODUCTION... 3 II II II II II II II II II II II II II I 4-5 ASSEMBLY... 6,7,8 II II II II II II II... 9

RIX COMPRESSORS. MICROBOOST Owner s Manual CONFIGURATION A MB-115 MB-230. November 21, 2002 APPLICABILITY [ A]

Transcription:

Halsey Taylor Owners Manual Refrigerated Marblyte Fountains with Back Panel HRFG - ER HRFG - SR HRFG - SER Installer To assure you install this model easily and correctly, PLEASE READ THESE SIMPLE INSTRUCTIONS BEFORE STARTING THE INSTALLATION. CHECK YOUR INSTALLATION FOR COMPLIANCE WITH PLUMBING, ELECTRICAL AND OTHER APPLICABLE CODES. After installation, leave these instructions inside the fountain for future reference. IMPORTANT ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON IMPORTANT! INSTALLER PLEASE NOTE. THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO WATER LINES IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY FROM THE BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNTAIN, CREATING AN ELECTROLYSIS WHICH CAUSES A METALLIC TASTE OR AN INCREASE IN THE METAL CONTENT OF THE WATER. THIS CONDITION IS AVOIDABLE BY USING THE PROPER MATERIALS AS INDICATED. ANY DRAIN FITTINGS PROVIDED BY THE INSTALLER SHOULD BE MADE OF PLASTIC TO ELECTRICALLY ISOLATE THE FOUNTAIN FROM THE BUILDING PLUMBING SYSTEM. PAGE 1 97878C (Rev. B - 11/04)

HRFG-ER/SR ROUGH-IN FINISHED FLOOR LEGEND: A = 1/4" O.D. TUBE WATER OUTLET B = 3/8" O.D. TUBE WATER INLET C = 1-1/4" O.D. WASTE TUBE (NOT INCLUDED) FIG. 1 97878C (Rev. B - 11/04) PAGE 2

HRFG-SER ROUGH-IN FINISHED FLOOR LEGEND: A = 1/4" O.D. TUBE WATER OUTLET B = 3/8" O.D. TUBE WATER INLET C = 1-1/4" O.D. WASTE TUBE (NOT INCLUDED) FIG. 2 PAGE 3 97878C (Rev. B - 11/04)

INSTALLATION INSTRUCTIONS 1. Install remote chiller. Remove front panel of chiller. Remove and discard cardboard inner pack from between compressor and side panel. Slide chiller onto the shelf and position it to the left within the guides on the shelf. NOTE: Building construction must allow for adequate air flow on both sides, top, and back of chiller. A minimum of 4" (102mm) on both sides and top is required. See chiller instructions for additional instructions. 2. Make water supply connections. The inlet port is marked on the chiller (1/4" O.D. copper tube). Bend the copper tube (provided) at an appropriate length from chiller to opening in frame. Install the in-line strainer (provided with chiller) by pushing it in until it reachs a positive stop, approximately 3/4" (19mm) on the marked chiller inlet port. Attach an unplated and deburred copper water inlet line and a service stop (not provided) to the in-line strainer. Turn on the water supply and flush the line thoroughly. DO NOT SOLDER TUBES WHILE INSERTED INTO THE STRAINER AS DAMAGE TO THE O-RINGS MAY RESULT. 3. Hang the upper panel on the mounting frame hanger. Align holes in the panel with the holes in the mounting frame. Be sure that panel is engaged with hanger at top of frame before releasing it. 4. Install fountain. Remove access cover plate on underside of fountains and save the screws. Mount the fountains to the upper panel and the wall frame with (4) 5/16" x 1-1/4" (32mm) long bolts, washers, and nuts. Tighten securely, but do not overtighten. Over tightening will crack the Marblyte Fountain. NOTE: The short fountain should be mounted to the upper left hand side of the panel. 5. Remove elbow from end of p-trap and attach it to drain tube. Re-attach elbow to p-trap and cut waste tube to required length using plumbing hardware and trap as a guide. 6. Make connection between remote chiller outlet tube and fountain(s). Outlet port is marked on the chiller (1/4" O.D. copper tube). Install a 1/4" union/tee (provided) on the marked chiller outlet port. Insert the 1/4" poly tubing coming from the fountain(s) into the union/tee. Turn on water supply and check for leaks. DO NOT SOLDER TUBES WHILE INSERTED INTO THE STRAINER AS DAMAGE TO THE O-RINGS MAY RESULT. (See figure 8 or 9). 7. These products are designed to operate on 20-105 PSIG supply line pressure. If inlet pressure is above 105 PSIG, a pressure regulator must be installed in the supply line. Any damage caused by reason of connecting these products to supply line pressures lower than 20 PSIG or higher than 105 PSIG is not covered by warranty. 8. Make electrical connections to the chiller. See chiller instructions. 9. Check stream height from bubbler. Stream height is factory set at 35-40 PSI. If supply pressure varies greatly from this, adjust the screw on regulator item 9 by using a small screwdriver through the small hole in the push button item 5 (See Fig.6). Clockwise adjustment will raise stream height and counter-clockwise adjustment will lower stream height. For best adjustment stream height should be approximately 1-1/2" (38mm) above the bubbler guard (See Figure 5, Page 5). 10. Mount lower panel. Loosen the (2) #10-24 x 5/8" (16mm) screws at frame bottom lip. Slide upper tongue of lower panel under lower edge of already installed upper panel. Tighten previously loosened screws securely. 11. Replace bottom access panel to fountain basin using screws provided. Tighten securely. Care and Maintenance of Halsey Taylor Marblyte Fountains Marblyte provides an exremely durable, nonporous surface which resists staining. Care is very simple. Routine cleaning with a soft sponge or cloth, or with water or non-abrasive aerosol foam cleaner, is all that is normally needed to give many years of trouble free service. Cleaners left standing on the fountain surface can dull the surface finish. Be certain to rinse all cleaning agents completely and polish with a soft cloth. Harsh abrasive cleaners are not required and should not be used. Mild abrasives such as liquid automotive cleaning compound or baking soda paste will remove simple scratches and stains. Cigarette burns can normally be removed without noticeable effect. Deeper scratches or gouges can be corrected with fine grit sandpaper (240 grit then 400 grit) or a green Scotchbrite pad. To maintain or regain luster and make cleaning easier, periodic applications of automobile wax or like products will keep the finish looking like new. 97878C (Rev. B - 11/04) PAGE 4

1/4" O.D. TUBE WATER INLET TO CHILLER 3/8" O.D. UNPLATED COPPER TUBE CONNECT COLD WATER SUPPLY BUILDING WATER INLET NOTE: WATER FLOW DIRECTION SERVICE STOP (NOT FURNISHED) FIG. 3 OPERATION OF QUICK CONNECT FITTINGS SIMPLY PUSH IN TUBE TO ATTACH TUBE IS SECURED IN POSITION PUSH IN COLLET TO RELEASE TUBE PUSHING TUBE IN BEFORE PULLING IT OUT HELPS TO RELEASE TUBE FIG. 4 FIG. 5 PAGE 5 97878C (Rev. B - 11/04)

5 13 6 2 9 7 10 BASIN 16 26 FIG. 6 TOP VIEW 23 8 3, 4 15 SEE FIG. 5 24 18 1 25 SEE FIG. 6 19 11, 14, 17 FIG. 7 97878C (Rev. B - 11/04) PAGE 6

TO BUBBLER CHILLER OUTLET 20 TO BUBBLER HRFG - ER / SR TUBE ROUTING 12 CHILLER INLET TO BUBBLER 22 CHILLER OUTLET HRFG - SER TUBE ROUTING 12 CHILLER INLET FIG. 8 FIG. 9 PAGE 7 97878C (Rev. B - 11/04)

ITEM NO. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 22 23 24 25 26 NS PART NO. LK464 15005C 40038C 40619C 45662C 45738C 50986C 51544C 61313C 75672C 112627543890 55996C 56087C 27201C 27658C 26839C 26837C 26835C 40045C 75554C 70012C 27026C 26833C 70683C 56092C 70682C 55969C 56053C 56025C 56056C 100322740560 15029C 45736C 75674C PARTS LIST DESCRIPTION Drain Retaining Nut Strainer Tailpipe Ferrule Push Button Push Button Sleeve Regulator Holder Bubbler Regulator Screw - Cap Screw #10-24 x 1/2 PH TR HD-Z Strainer Push Button - Extension Bottom Cover Plate-Short Bottom Cover Plate-Extended Back Panel HRF-SER Back Panel HRF-ER Back Panel HRF-SR Hex Nut Insert - Threaded Bubbler Locknut Lower Panel HRF-SER Lower Panel HRF-ER/SR Union - 1/4" Poly Tubing - Cut To Length Tee - 1/4" Fountain-Galaxy Gray(HRFG-S) Fountain-Galaxy Gray(HRFG-E) Fountain-Black(HRFG-S) Fountain-Black(HRFG-E) Gasket - Black Nipple Assembly Nut - Regulator Mounting Wrench - Allen 7/64 TROUBLE SHOOTING & MAINTENANCE Orifice Assy: Mineral deposits on orifice can cause water flow to spurt or not regulate. Mineral deposits may be removed from the orifice with a small round file not over 1/8" diameter or small diameter wire. CAUTION: DO NOT file or cut orifice material. Stream Regulator: If orifice is free of material deposits, regulate flow as instructions on page 4(Step 9). If replacement is necessary, see parts list for correct regulator part number. Actuation of Quick Connect Water Fittings: Cooler is provided with lead-free connectors which utilize an o-ring water seal. To remove tubing from the fitting, relieve water pressure, push in on the gray collar while pulling on the tubing.(see Fig.4, Page 5) To insert tubing, push tube straight into fitting until it reaches a positive stop, approximately 3/4". 2222 CAMDEN COURT OAK BROOK, IL 60523 630.574.3500 PRINTED IN U.S.A. 97878C (Rev. B - 11/04) www.drinkingfountaindoctor.com 800-518-5388 PAGE 8