Rev. 1. Cryogenics Thermoflasks. 2122, 2123, 2124, 2129, and 2130

Similar documents
DUQUESNE UNIVERSITY. Liquid Nitrogen Safety

Artic Express. Cryogenic Dual Shippers. Visit us online to register your warranty

Model: 8126/ /50 Liter LN2 Supply Tank. Operating and Maintenance Manual Manual No: Rev. 1

OPERATING & HANDLING INSTRUCTIONS

Operating Instruction Manual for Liquid Nitrogen Containers. CRY/CRYC Series. Hagavish st. Israel Tel: , Fax:

Cryogenics is the science of ultra low temperatures. Low temperatures are achieved by the liquefaction of gases.

Type 131. Roller base. Information and Operating Instructions for Dewar Vessels Type 131 up to 135 boxed shaped KGW-ISOTHERM

THE UNIVERSITY OF NEWCASTLE - DISCIPLINE OF MEDICAL BIOCHEMISTRY

KGW-ISOTHERM. Information and Operating Instructions for Dewar Vessels Type 26 to 29 B or B-E

Cryogenic Materials Operating Procedure and Safety Requirements

Locator and Locator Plus Cryogenic Storage Vessel with or without Ultrasonic Level Monitor Operation Manual and Parts List

EHS Laboratory Guidance: Cryogenic Material

School of Plant Biology - Liquid Nitrogen Induction

EXPERIENCE WITH CRYOGENICS SAFETY, PROBLEMS AND SOLUTIONS

Owners Manual CM Class SSC Class SSC-ET Class VS Class LD Class

Each cryogenic liquid has its own specific properties, but most cryogenic liquids can be placed into one of three groups:

THE UNIVERSITY OF NEWCASTLE- DISCIPLINE OF MEDICAL BIOCHEMISTRY. STANDARD OPERATING PROCEDURE PROCEDURE NO: GLP 022 MOD: 1st Issue Page: 1 of 8

THE UNIVERISTY OF NEWCASTLE - SCHOOL of BIOMEDICAL SCIENCES

Standard Operating Procedure (SOP)

USER MANUAL FLOW SELECTOR PM1000 SAVE THESE INSTRUCTIONS. Federal (USA) law restricts this device to sale by or on the order of a physician.

Product Manual. Cryo-Cyl Liquid Cylinder 35/50 LP. Designed and Built by: Chart Inc Airport Dr. Ball Ground, GA USA (800)

MATERIAL SAFETY DATA SHEET

MATERIAL SAFETY DATA SHEET

Safe Handling & Use of Liquid Nitrogen and Other Cryogenic Gases

Lecture Demonstrations Safety Manual & New Staff Induction

U S E R M A N U A L CAUTION. SAVE THESE INSTRUCTIONS Federal (USA) law restricts this device to sale by or on the order of a physician.

TactAir PCP Fill Kit/Adapter. Operation Manual

MANAGEMENT OF LIQUID NITROGEN

Material Safety Data Sheet Potassium nitrate MSDS# Section 1 - Chemical Product and Company Identification MSDS Name: Potassium nitrate Catalog

Safe Handling - Dimethylamine

Safe Handling Methylamine (Monomethylamine)

Hazardous Substances Policy - Control Measures POLICY

Compressed Gas Properties. Introduction. Compressed Gas Properties. Definition of a Compressed Gas

HAYWARD FLOW CONTROL TFS SERIES FLOW METER INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

AND OPERATION INSTRUCTIONS

3M Liqui-Cel EXF-4x13 and 4x28 Series Membrane Contactors

ALU-CD 12, ALU-CD 25, ALU-CD 35, ALU-CD

U S E R M A N U A L AIR FLOWMETER. MODELS: 1MFA2001 (shown) 1MFA9001 CAUTION. ISO Certified

USER MANUAL SAVE THESE INSTRUCTIONS. For the most current manual revision, please visit our Website:

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

CSA Sample Draw Aspirator Adapter Operator s Manual

B. Working with liquid nitrogen local rules when using the X-ray facility, room 5.20, Flowers building

Compressed Gases and Cryogens

Operation Manual. O2 Quickstick. Oxygen Analyzer

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)

MATERIAL SAFETY DATA SHEET

BlenderBuddy 2. Operating Manual & Instructions For Use ENGLISH R233M01 REV. A

Circular Sight Windows

3M Liqui-Cel EXF-14x28 and 14x40 Series Membrane Contactor

BP OIL -- TOLEDO REFINERY

INSTRUCTION MANUAL MP4AR Remote Convection Gauge Range: 1 x 10-3 Torr to 1 x 10+3 Torr

Material Safety Data Sheet Sodium Nitrate MSDS# Section 1 - Chemical Product and Company Identification MSDS Name: Sodium Nitrate Catalog

Operation Manual. O2 Quickstick. Oxygen Analyzer 08.17

Sterile Visual Flow Indicator

MSDS Ecopro Silicate Masonry Paint 1-170

Instruction Manual LIMITED 1 YEAR WARRANTY. Hydraulic Punch Driver Read this material before using this product.

PURPOSE OF THE POLICY

INSTRUCTIONS FOR MODELS SG3897 AND SG3898 CROSS PURGE ASSEMBLIES

MATERIAL SAFETY DATA SHEET

Model nd Order SQUID Gradiometer System

HEAT EXCHANGE AND TRANSFER, INC. 500 Superior Street Carnegie, PA (412) Fax: (412)

453 Series Steam Heated Vaporizing Regulator

User Instruction Manual

Stainless Steel 142 mm Filter Holder YY

USER GUIDE. Fog Generator. ATMOSPHERE APS TM Series Haze Generator. MAX APS TM Series. No: , Revision A/a

Model ASSEMBLY and OPERATING INSTRUCTIONS

Operation Manual. Pro CO 2 Analyzer. Carbon Dioxide Analyzer. Rev

COMPACT METAL bender 99826

0RGHO /6 /6/6/6 /LTXLGÃ/HYHOÃ(TXLYDOHQWV

Working with Cryogenic Liquids

Operating Manual ALU 7 - ALU 10 - ALU 20 - ALU 26 ALU 35 - ALU 60 - ALU 100

Operating Manual. Models AQT-02 & AQT-COO2 Manual No. MON004 (Rev 2 April 2000)

200 PSI HIGH-FLOW AIR SOURCE KIT

ZHE+ Zero Headspace Extractor Operation & Instruction Manual

Pub.No Flushing out your heat transfer system was a dirty job, a big expense, and a serious bummer.

SDS -Series 4C-D201/-D202 Supplemental Drying System User s Manual

Operating Instructions and Parts Manual 24529

TITAN FLOW CONTROL, INC.

ROPV R40 E Series User Manual

INSTALLATION MANUAL Matheson Tri-Gas Cabinet Enclosures

60 farm jack. Distributed exclusively by Harbor Freight Tools Mission Oaks Blvd., Camarillo, CA 93011

S1, S2, S3, S5, S6, S7, S8, S12 and S13 Separators Installation and Maintenance Instructions

Operation Manual. Pro He Alarm TM. Helium Analyzer. Rev 08.17

TOP VALVE. Pat. #5,857,486 & 5,944,050. Mid-Range Pressure PSIG Back Pressure and Pressure Relief Valves. Instruction Manual

AC1810 / AC1810-A TECHNICAL SPECIFICATIONS. Operating Pressure psi ( kgs/cm²) [AC1810] Displacement. Net Weight

MATERIAL SAFETY DATA SHEET

COOPER POWER. SERIES VariSTAR type composite light-duty under-oil (CLU) MOV arrester installation instructions. Surge Arresters MN235023EN

Hygienic Bubble Trap Installation and Operations Manual

Material Safety Data Sheet Calcium Sulfate Hemihydrate MSDS# Section 1 - Chemical Product and Company Identification MSDS Name: Calcium Sulfate

RK-IR Sample Draw Aspirator Adapter Operator s Manual

Material Safety Data Sheet Potassium nitrite MSDS# Section 1 - Chemical Product and Company Identification MSDS Name: Potassium nitrite Catalog

J138RSH and J150RSH 3/8" J138RSH 1/2" J150RSH. 3/8" Drive Sealed Head Ratchet 1/2" Drive Sealed Head Ratchet. Operation and Maintenance Manual WARNING

Liquid nitrogen. Safetygram 7

GETZ EQUIPMENT INNOVATORS PART No. 4G59678 CARBON DIOXIDE MINI PUMP FOR EXTINGUISHER SERVICE (Revised )

MODEL NUMBER: PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank

Psyclone TM. Protimeter Thermo-Hygrometer. GE Sensing. Operating Manual. INS7800, Rev. A (September 2007)

Taylor Wharton Germany GmbH Mildstedter Landstraße Mildstedt Tel.: Fax:

1. PRODUCT IDENTIFICATION 2. COMPOSITION / INFORMATION ON HAZARDOUS INGREDIENTS

INSTRUCTIONS FOR MODELS UPH & UPHS HIGH FLOW, HIGH PURITY GAS REGULATORS

INSTRUCTIONS PARTS LIST

Transcription:

Operating Manual Application Catalog Number 056-720-00 Rev. 1 Cryogenics Thermoflasks 2122, 2123, 2124, 2129, and 2130 Important Read these operating instructions. Failure to read, understand and follow the instructions in this manual may result in damage to the unit, injury to operating personnel, and poor equipment performance. s Caution All internal adjustments and maintenance must be performed by qualified service personnel. s 2017 Thermo Fisher Scientific. All rights reserved.

Handling Thermoflasks It is recommended that care be taken in the use of Thermo Scientific Thermoflasks. Any product used under vacuum is a potential hazard and, therefore, should be treated with caution. If in doubt, consult the safety regulations of your laboratory or institution. Specific warnings are listed below to avoid some of the more common errors. Failure to follow proper procedures, heed warnings, and cautions can result in failure of the flask with potential expelling of the contents and subsequent harm to user. Warning Contact of liquid nitrogen with the skin or eyes may cause serious (freezing) injury. When handling liquid gases, appropriate Personal Protection Equipment (PPE) must be worn, such as goggles or facemasks, and insulated or rubber gloves large enough to allow quick removal, and insulated or rubber aprons. s Caution A potentially dangerous situation could result from pouring liquid gases into a Thermoflask without pre-cooling the flask. When pouring liquefied gases from one container to another, the receiving container should be cooled gradually to prevent thermal shock. The liquid should be poured slowly to avoid splashing. A receiving vessel should always be vented to the atmosphere and high concentrations of excess oxygen and/or nitrogen should not be allowed to collect. s Warning Nitrogen gas can cause suffocation without warning. Store and use liquid nitrogen only in a well-ventilated place. As the liquid evaporates, the resulting gas displaces the normal air in the area. (The cloudy vapor that appears when liquid nitrogen is exposed to the air is condensed moisture, not the gas itself. The issuing gas is invisible.) In closed areas, excessive amounts of nitrogen gas reduces the concentration of oxygen and can result in asphyxiation. Because nitrogen gas is colorless, odorless, and tasteless, it cannot be detected by the human senses. Breathing an atmosphere that contains less than 19.5% oxygen can cause dizziness and quickly result in unconsciousness and death. Therefore, the use of oxygen monitoring equipment is strongly recommended. s Caution It is recommended to have this vessel tested by the manufacturer or qualified cryovessel service technician every 7-10 years, regardless of any problems (or lack thereof) there may have been in the past. This will help insure your samples against sudden loss of liquid nitrogen due to vacuum failure. s Warning All Thermoflasks in stainless steel containers (catalog numbers 2122~2124) have vented lids to prevent build-up of gas pressure when holding a gassing substance. The ability of the vent to release pressure should be checked periodically. s 2 Thermoflasks

Handling Thermoflasks (cont.) Warning Do not cover any glass Thermoflask with any fixed or heavy object that might form a seal around the rim either naturally, or induced by freezing. s Warning If liquid gases or other materials of extremely low temperatures are being used, ONLY use a stirring rod with a PTFE (polytetrafluoroethylene) or comparable form of protective coating, to mix or stir substances in the Thermoflask. s Liquid Nitrogen Holding Times Size Holding Time 1 Liter 38 Hours 2 Liters 48 Hours 4.5 Liters 54 Hours The holding times in the table on the left are intended as a guide only, to illustrate the probable time it takes for a stainless steel Thermoflask, with lid, to empty completely after being filled with liquid nitrogen. The times may change depending on higher or lower ambient temperatures, whether or not the lid is removed for examination of the contents, and according to the mass of the material being frozen. Even though the Thermoflasks may be almost empty of liquid nitrogen, they will continue to be effective storage vessels for frozen material because the contents will be held in the vapor phase of the nitrogen, i.e. the liquid nitrogen will have boiled to become a very low temperature gas. This can benefit users who wish to store materials in a frozen state, but not at the exceptionally low temperature of the liquid nitrogen itself. Specifications Catalog Number Capacity - Liters Inside Diameter - Outside Diameter - Height - Ship Wt. - lbs (kg) 2122 1.0 3.6 (9.1) 4.6 (11.7) 9.0 (22.9) 6 (2.7) 2123 2.0 4.2 (10.7) 5.6 (14.2) 10.7 (26.9) 8 (3.6) 2124 4.5 5.9 (15.0) 7.2 (18.2) 13.8 (35.0) 10 (4.5) 2129 1000ml 5.1 (13.0) 6.3 (16.0) 4.5 (11.6) 8 (3.6) 2130 1900ml 6.1 (15.5) 7.3 (18.5) 5.4 (13.7) 10 (4.5) Thermoflasks 3

Operation Before using your any vessel, carefully inspect it. Check for signs of damage, such as scratches, chips or discoloration of glass. If any damage is found, do not use! It is advisable to fill (see Filling Instructions) all new units with liquid nitrogen and watch liquid nitrogen loss rate for a few days. If there are any problems, call Technical Services as soon as possible. Use a wooden yardstick to measure liquid nitrogen level. Level will be indicated by frost line which develops when dipstick is removed and waved in a back and forth motion away from the user. To avoid damage to your cryogenic storage vessel which may result in premature vacuum loss, it is important that the following procedure be used during the addition of liquid nitrogen to a warm vessel: 1. Add only a small amount of liquid nitrogen (10% of unit volume) to new or warm vessels. Glass Lined Dewar Sealed Vacuum Container 2. Allow this small amount of liquid nitrogen to sit in the covered vessel for a minimum of 2 hours. This will limit stress caused by the sudden temperature change associated with adding liquid nitrogen to a warm vessel. 3. Add an additional 20% of unit volume of LN2 to vessel. 4. Allow vessel to sit for 48 hours and monitor liquid nitrogen consumption. 5. Fill vessel as desired. Remember to allow for displacement of liquid nitrogen when canisters and canes are inserted. 6. Insert and remove samples slowly. Allow liquid nitrogen to run out of samples. Caution Never overfill liquid nitrogen vessels. s 4 Thermoflasks

THERMO FISHER SCIENTIFIC STANDARD PRODUCT WARRANTY (LN2 Vacuum) The Warranty Period starts two weeks from the date your equipment is shipped from our facility. This allows for shipping time so the warranty will go into effect at approximately the same time your equipment is delivered. The warranty protection extends to any subsequent owner during the first year warranty period. During the first year, component parts proven to be non-conforming in materials or workmanship will be repaired or replaced at Thermo's expense, labor included. LN2 Vacuum Integrity is covered for one year. Installation and calibration are not covered by this warranty agreement. The Technical Services Department must be contacted for warranty determination and direction prior to performance of any repairs. Expendable items, glass, filters and gaskets are excluded from this warranty. Replacement or repair of components parts or equipment under this warranty shall not extend the warranty to either the equipment or to the component part beyond the original warranty period. The Technical Services Department must give prior approval for return of any components or equipment. At Thermo's option, all non-conforming parts must be returned to Thermo postage paid and replacement parts are shipped FOB destination. THIS WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES, WHETHER WRITTEN, ORAL OR IMPLIED. NO WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE SHALL APPLY. Thermo shall not be liable for any indirect or consequential damages including, without limitation, damages relating to lost profits or loss of products. Your local Thermo Sales Office is ready to help with comprehensive site preparation information before your equipment arrives. Printed instruction manuals carefully detail equipment installation, operation and preventive maintenance. If equipment service is required, please call your Technical Services Department at 1-800-438-4851 (USA and Canada) or 1-740-373-4763. We're ready to answer your questions on equipment warranty, operation, maintenance, service and special application. Outside the USA, contact your local distributor for warranty information. Rev. 0 5/10 ISO 9001 REGISTERED Material in these instructions are for information purposes only. The contents and the product it describes are subject to change without notice. Thermo Fisher Scientific makes no representations or warranties with respect to these instructions. In no event shall Thermo be held liable for any damages, direct or incidental, arising out of or related to the use of this manual. Instruction Sheet 056-720-00 (7002122) 1 41172 9/21/16 Updated information and safety symbols ccs 0 -- 1/15/10 Original (was 056-720-00 6/10/08) ccs Rev ECR/ECN Date Description By Thermo Fisher 401 Millcreek Road (800) 438-4851 Scientific Marietta, OH 45750 (740) 373-4763 Thermoflasks 5