User s Guide. Pressure Controller for liquid delivery systems

Similar documents
User s Guide. Vacuum Controller for liquid delivery systems

User s Guide. CO2 Controller for miniature incubators

User s Guide. CO2 & O2 Controller for miniature incubators

Overview. Front Panel: Keypad and Display

MCQ Gas Blender 100 Series 3 Channels Gas Mixer

User Manual MFCS TM -EZ

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP

Warner Instruments, Inc Dixwell Avenue, Hamden, CT (800) / (203) (203) fax

Pegas 4000 MF Gas Mixer InstructionManual Columbus Instruments

UNIVERSAL MASK TEST SYSTEM

5 Channel Calibrator

PRESSURE SENSOR - ABSOLUTE (0 TO 700 kpa)

INSTRUCTION MANUAL. January 23, 2003, Revision 0

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

T i m i n g S y s t e m s. RACEAMERICA, Inc. P.O. Box 3469 Santa Clara, CA (408)

STANDARD OPERATING PROCEDURES. Andersen Instruments Federal Reference Method (FRM) Ambient Particulate (PM 10 /PM 2.

ABRASIVE REGULATOR II

Instructions for Assembly, Installation, and Operation of the Gas Addition Kit Accessory with the CEM Discover Systems

Yoke Block Instruction Manual

Microfluidic Demonstration

BPS-2, Rev TABLE OF CONTENTS

Superconducting Susceptometer (MPMS-5S) Quantum Design Room 296 (MPMS)

Operations Manual. Internal automatic Pressure control for orbital tube welding. By Exel Orbital Systems, Inc. Page

ABRASIVE REGULATOR II

Model 687 Mouse Ventilator User s Manual. Model 687 Mouse Ventilator

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

GA-300 Gas Analyzer. Technical Note. Overview. Front Panel. iworx Systems, Inc. GA-300

GALISO SOAP OPTION FOR PCT-ADW-D

HumiSys HF High Flow RH Generator

PH01 Perfusion Cannula Manual

Do Not Print This Page.

- Repeat calibration until desired results are reached otherwise set SW2 and SW1-8 open.

Basic Nitriding Sampling System Hydrogen Analyzer with Calculated % DA, % NH 3, and K N Values. Operations Manual

RAM 4021-DPX Operation Manual

WIDDER TOOLS. HPICAL Calibration Station 1 (203)

BGA244 Binary Gas Analyzer

Table of contents. Table of contents 1. Installation 2. Introduction ( Display, monitor ) 3. Introduction ( Operating elements ) 4

Gas Pressure Sensor (Order Code GPS-BTA)

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

In Vivo Scientific, LLC INSTRUCTION MANUAL

MASK INTEGRITY TEST ACCESSORY (MITA) MODEL 8120

SERIES 20 CHAMBERS THE RC-25 AND RC-25F CHAMBERS ASSEMBLY

SomnoSuite FAQ. Setup. Calibration 4. What are the calibration requirements for the SomnoSuite? Settings

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

RK-IR Sample Draw Aspirator Adapter Operator s Manual

CSA Sample Draw Aspirator Adapter Operator s Manual

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

Yoke Block Instruction Manual

Radnoti Liver Perfusion System

Techcon Systems TS1258 Pressure Pot

Instruction Manual. PLT Series. 1. General Specification. 2. Installation. 3. Wiring. 4. Function. 5. Setting & Calibration

RAM Operation Manual

MAGNA-CHEM AUTOMATIC CHLORINATOR - MODEL: CSA-2P MAGNA ORP Chlorine Pump

with O 2 Controller Instruction Manual

ATD /8 x 50 Retractable Air Hose Reel Owner s Manual

Physics Experiment 17 Ideal Gas Law Qualitative Study

Vacuum grease can be applied to Warner chambers by use of a syringe or a small artist s dotting brush. Both approaches are described below.

Research Grade Blood Pressure Transducer User's Manual

MANUAL BE SERIES Test Benches

Application of vacuum grease

Calibration Gas Instrument INSTRUCTION MANUAL. Release I. Advanced Calibration Designs, Inc.

RK LEL Sample Draw Aspirator Adapter Operator s Manual

2 CYLINDER MOBILE CART USER S MANUAL / INSTRUCTIONS

J Air and Water Kit Instructions Part# 02584

G92 Series BASOTROL Automatic Pilot Gas Valve

215 Liquid Handler Up-Grade Manual

Installing ASI Umbilical Delivery Systems

Digital Vacuum Regulator

PANACEA P200 STAINLESS STEEL USER MANUAL

ELECTRONIC PLC SERIES Test Benches

LEAK TROUBLESHOOTING

QE-1, Rev Warner Instruments, Inc Dixwell Avenue, Hamden, CT (800) / (203) (203) fax

EQUIPMENT OPERATION MANUAL. Loctite Dispense Valve Manual

ACV-10 Automatic Control Valve

PC7-C Flowmeter O2/N2O Sedation Unit Instruction Manual

RAM 4021 Operation Manual

BioAerosol Nebulizing Generator. Operation and Maintenance User Manual

200 PSI COMPRESSORS - MODEL NUMBERS

Digital Vacuum Regulator

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

Syringe, Distribution Valve and Infusion Pump Removal/Replacement ATTENTION SYRINGE REPLACEMENT

100C Air Compressor Kit

Issue OWNER S MANUAL. GAMMA RACQUET SPORTS GAMMA Sports All Rights Reserved

Model # HC-MIS INSTRUCTION MANUAL

DPC-30 DPC-100. Reference Manual

453 Series Steam Heated Vaporizing Regulator

Installation Instructions

400C & 450C DUAL PERFORMANCE VALUE PACKS

DGT-CO2BX, Digital CO 2 Controller. Manual

Water Weir Flow Controller. Introduction. Safety Precautions. Mounting the Hardware

Table Top and Convertible Anesthesia Machine Models: M3000 and M3100 (SHOWN WITH OPTIONAL EQUIPMENT)

SERIES 20 CHAMBERS THE RC-26, RC-26P AND RC-26G CHAMBERS ASSEMBLY

Linkam Scientific Instruments USER GUIDE DSC600. Temperature Controlled Stage

INSTALLATION AND OPERATING INSTRUCTIONS BIG TEX VENTED GAS LOGS

KEM Scientific, Inc. Instruments for Science from Scientists

GILMONT ACCUCAL FLOWMETERS

Compact Triple Cabinet Outlet Station Model Installation and Operating Instructions

Maintenance of the Electronic ( EPC ) Pressure Controllers on GCs

Tridak Model 1060 User Guide. Syringe Filling System

Bante810 Benchtop Dissolved Oxygen Meter Instruction Manual

Transcription:

Flow Control User s Guide Pressure Controller for liquid delivery systems Precise Pressure Control throughout the experiment Flow control Compatible with any perfusion system Ideal for Small Volume Delivery systems Compatible with Imaging setups Ph: 877-853-9755 www.biosciencetools.com

Contents Specifications............................................... 2 Introduction................................................ 3 Installation Guide............................................ 3 Software control and monitoring............................... 4 Warranty................................................... 5 Gas Mixture Adapter, SH-A.................................... 6 Pressurized Cylinders, PC...................................... 7 Small Volume Delivery System, SVDS1........................... 8 Specifications Output Range Input Sensors Feedback RS232 port 0 to 385/750+/-0.5mmHg (other ranges available upon request) not required built-in pressure sensors from output pressure sensor To monitor and control pressure Output: easy disconnect for 1/8 O.D. tubing #10-32 threaded includes barbed and luer fitting includes easy disconnect fitting for 1/4in. O.D. tubing Size (Controller) : 13Wx6Hx9D in Power Supply 94 to 234 VAC, 50/60 Hz

Introduction The complete pressure control system comes with a controller, tubing to connect to custom setups, and fitting. No pressurized source of gas is required to operate the system. During operation, the controller is continuously monitoring the output pressure level to provide consistent and defined flow of solution. Installation Guide 1 Using provided fitting connect 1/8 O.D. black tubing to your setup: pressure switch PS-V8P, gas mixture adapter SH-A, pressure cylinders PC or a small volume delivery system SVDS1/2. Some additional tubing and fitting might be required. Usually luer-lock fitting or other easy-connect adapters are used to splice different diameter tubing while connecting to 1/8 O.D. tubing provided, which fits inside OUTPUT port on the back of the controller. make sure there are no obvious leaks. After splicing tubing to your setup, simply push the tubing inside OUTPUT port all way, and slightly pull back to clamp. In order to disconnect the tubing, push YELLOW rim inside the connector, and pull the tubing out. Connect power cable to the controller. Plug the power cable into the wall outlet. I O RS232 OUTPUT 3

2 Turn the controller ON. Upon turning the controller ON, the display will show three control buttons, and numerical key-pad. Buttons: ZERO adjust the output by subtracting (offset) the initial pressure readings (when no pressure applied) from every subsequent pressure reading. This is an optional procedure and can be done just after the controller was turned ON. START starts the pressure generator, after which the buttons turns to STOP button stops the generator and releases the output pressure. CLOSE closes the output so no pressure is supplied and regulated by the controller. Can be used to observe the leak in the customer setup. The buttons turns to OPEN opens the output back to normal configuration. KEY-PAD is used to adjust the output pressure: CLEAR clears the windows from the previous SET pressure level; ENTER enters the new SET level into the controller memory. Initially, the output is OPEN to the air. If the initial pressure is not 0, touch button ZERO to compensate his offset. Adjust/SET the output pressure using the key pad and CLEAR button. Put the SET pressure level into the controller memory by touching ENTER key. Touch button START to generate the pressure. ZERO START CLOSE mmhg 15.0 SET 15 15 1 2 3 4 5 6 7 8 9 Clear 0 Enter 3 The output pressure will regulate solution flow rates in your liquid delivery setup. IMPORTANT: in case of open (not-sealed) systems, it is normal for pressure reading being low. This, however, should be avoided since the controller is designed to provide pressure to closed systems in order to regulate flow rates in small volume delivery setups. 4

Software control and monitoring Use NULL-modem cable to connect the controller to a computer RS232 port. The port should be set to 115,200 baud, 8bits, 1stop, NO parity. Every command should be followed by decimal 13 code (/n).!s - Start!Z - stop and Zero output!c - Close output!o - Open output!v - return pressure Value in mmhg Pvvv.v!R - return Reference value (Set in mmhg Snnn)!Pvvv - set Pressure value in mmhg!n - return serial number!? - return list of commands!a - return A scale calibration (An.nnn)!B - return B offset calibration (Bnnn.n)!D - return Digital output (Dnn - first n for output valve, second n for Zero valve, 1 - open, 0 - closed)!l - show calibration screen!0 - offset compensation of output pressure, similar to ZERO button 5

Calibration procedure. After sending!l command, the controller will erase the previous calibration values, and will store the default values. After sending!l command to the controller, the display will show two additional buttons: HIGH initiates the calibration procedure by supplying high level of 300mmHg pressure to the output. After the pressure readings are stabilized, enter the correct value measured with a third party manometer, using CLEAR key, numerical key-pads, and then ENTER key (should be around 300mmHg value). After the first entry, the button turns to LOW, and the controller starts supplying low level of 50mmHg. Again, after the pressure readings are stabilized, enter the correct value using the key-pad. After, the second entry, the buttons turns to SAVE button, which can be used to put the calibration values into the controller memory. CANCEL cancel the calibration procedure. The controller should be turned OFF before resuming the normal operation. HIGH CANCEL mmhg 300.0 SET 300 300 1 2 3 4 5 6 7 8 9 Clear 0 Enter 6

Warranty This product is warranted to be free from defects in material and workmanship for the duration of one year. Normal wear, or damage resulting from abuse, accident, alteration, misuse, service by an unauthorized party or shipping damage, are excluded from this warranty and are not covered. Bioscience Tools will repair or replace the defective product covered by this warranty free of charge if it is returned, postage prepaid, to Bioscience Tools, ph: 1-877-853-9755. 7

Gas Mixture Adapter, SH-A This adapter is used to pressurize or to deliver gases, CO2/O2 for example, to experimental solutions in syringe barrels or other containers. Continuous bubbling of the experimental solutions ensures gas saturation inside the solutions. The adapter can be also used to pressurize the solutions by connecting to optional pressure cylinders, PC, available in different sizes - volumes. 1 2 3 4 1. Mount the adapter on a 0.5in. post (included with SH-1A syringe holder) using provided X-block. 2. Eight luer connectors positioned along the adapter deliver gases to eight separate solutions through 2-way valves (stop-cocks) and thin Teflon or polyethylene tubing. The tubing can be replaced with any custom tubing and other means to dissipate gases inside solutions (aquarium stones, for example). If less then 8 solutions are used, the extra outlets can be closed. 3. Use soft tubing with luer-lock to connect to a source of gas mixture through a 3-way valve attached to the end. 4. Another end can be plugged, or connected to the second adapter (several adapters can be connected in sequence to use the same gas mixture).

Pressurized Cylinders, PC 9

Small Volume Delivery System, SVDS1 SVDS1 system can be used with a pressure source, or solutions can be withdrawn by a negative pressure supplied by CFPS-1U units. The output solution tubing can be connected to valves of a solution switch, and then to a MM, PM or ZMM micro-manifolds. The pressure input should be connected to a regulated pressure source using 1/16 I.D. tubing and T/Y-connectors one pressure input to all eight (or less) pressure input luer ports positioned on the top. The solutions will be switched by turning ON/OFF the appropriate valves by the controller of the perfusion system. The applied pressure will push the solution through the opened line. The system ships fully assembled. Below are the instructions on connecting the replacement tubing. 1 2 3 4 1. Measure and cut eight (or fewer) pieces of polyethylene tubing, 1/16 O.D. - fitting sleeves. Put a short piece of the fitting sleeve over delivery tubing (the system is shipped with 2 of Teflon tubing per each channel). Insert the sleeve into the ferrule. 2. Secure the tubing inside the plastic block by tightening the threaded nut (do not tighten completely yet). 3. Screw in conical plastic tube (included), and pull the delivery tubing so that the end of it still touches the conical bottom. Tighten the threaded ferrule fitting. ALTHOUGH PROVIDED FITTING WILL ENSURE AIRTIGHT SEAL, THREADED PORTS and TUBES MIGHT REQUIRE SOME GREASE TO MAKE AIR-TIGHT SEAL inside THREAD. 4. The system can be mounted on a custom 6 mm O.D. rod or on 1 long threaded aluminum rod, which can be mounted on a standard 0.5 O.D. stand through X-block (X-block and a threaded rod are included). This allows positioning the solutions near your samples, to minimize the dead volume. If valves used to open solution lines, connect Teflon tubing to valve s inlet using sleeves of soft tubing. The valve s outlet should be connected to a micropipette, a micro-manifold or a chamber using another tubing. 10

4a 4b 11

12