Anes Machine Use and Pre-use Check - CA1 focus

Similar documents
Anesthesia Machine Intro

Draeger Fabius GS Pre-Use Check

Anesthesia Delivery Systems What Do I Need to Know About My Machine? A Workshop James H. Philip, MEE, MD, CCE

Fabius will not compensate for Lung Compliance or Changes in lung compliance

Technology Topics 2017 James H Philip MEE, MD, CCE page 1

Working version subject to Departmental approval. Drafted by Dr. Olympio and reviewed by clinical members of The Capital Equipment Committee

Flow meter. bellow vaporizer. APL valve. Scavenging system

New Anesthesia Delivery Systems What Do I Need to Know About My New Machine?

VIMA. (Volatile Induction and Maintenance Anesthesia) How and Why. James H. Philip M.E.(E), M.D.

Aespire 7100 Essential performance Compact design

Anesthesia Machines. Inhaled Anesthetic Agents

SATURN EVO COLOR A N A E S T H E S I A S Y S T E M. Manufacturer of high quality anaesthesia products

Fabius Tiro TM. Designed for your environment. Because you care. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Hallowell EMC 2000 and 2002 Veterinary Ventilator Set-up, Use, and Troubleshooting

Narkomed MRI-2. A perfect fit for the MRI environment. Because you care. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Recommendations on Checking Anaesthesia Delivery Systems

THE GE AISYS ANAESTHETIC MACHINE

Effective 2/1/17. SC1 Service Call PER Visit $76.00

Keeping anaesthetic pollution to minimum in theatre environment

Anesthesiology Research and Scholarship. Follow this and additional works at:

S/5 Aespire. Quick Reference Guide

Operators Manual. Supera Floor Stand Anesthesia Machine M1000. Models: M1000 Basic Non-rebreathing M1200 Basic M1200

The Anesthesia Machine (con t) The primary cause of machine malfunction is failure to check Never start without the American Express items What is the

HONG KONG COLLEGE OF ANAESTHESIOLOGISTS TECHNICAL GUIDINES RECOMMENDATIONS ON CHECKING ANAESTHESIA DELIVERY SYSTEMS

Fabius Tiro TM. Designed for your environment. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Operators Manual. Supera Wall Mount Anesthesia Machines. Models: M2300 M2500. (All shown with optional equipment) M2300 M2500

SomnoSuite FAQ. Setup. Calibration 4. What are the calibration requirements for the SomnoSuite? Settings

Checking a Breathing System

Hallowell EMC Vacuum / Scavenging Interface

Table Top and Convertible Anesthesia Machine Models: M3000 and M3100 (SHOWN WITH OPTIONAL EQUIPMENT)

Hallowell EMC Anesthesia WorkStation Operating Manual

Anesthesia Workstation

Landmark. Veterinary Anesthesia Systems. Operator s Manual P/N

GE Healthcare. Aestiva/5. More than superior ventilation

A9600 Anesthesia Workstation. Your healthcare, we care.

Aestiva/5. Operation Manual - Part 1. Software Revision 4.X System Controls, Operation, Checkout

PC7-C Flowmeter O2/N2O Sedation Unit Instruction Manual

GE Healthcare. Avance Carestation. Upgrade promotions guide

A few seconds after turning on, the screen changes to Set Up Screen Before adjusting the pressure, calibrate the O 2 sensors

Anesthesia. Midmark Animal Health Products

Carestation 650. Physical Specifications Product Description Carestation 620 A1 ANESTESI CARESTATION 650

M5400 Operators Manual

International Journal of Science, Environment and Technology, Vol. 5, No 5, 2016,

Your patients, our primary focus. Siesta i Whispa anesthesia machine

Fabius plus. The plus that makes all the difference. Because you care. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Breathing Systems. Professor Khalid Bashir

PORTER INSTRUMENT COMPANY, INC.

AUTOVENT 4000 VENTILATOR

Service Manual. Anesthesia System ANESTHESIA S ANESTHESIA SYSTEM

Prima SP2/3 Anaesthetic Machine Range Service Manual Partnership for Life

2 CYLINDER MOBILE CART USER S MANUAL / INSTRUCTIONS

COMPACT TRIPLE WALL OUTLET STATION MODEL INSTALLATION AND OPERATING INSTRUCTIONS

Welcome to the Specialized Medical Services Respiratory training webinar series!

Technical Data and Specifications

Testing anaesthetic machines, ventilators and related equipment

The Anesthesia Gas Machine

Anesthesia Solutions. Prima SP and Prima SP2 Anesthesia Systems. The Future of Anesthesia. Partnership for Life

Your customized anesthesia workstation DRÄGER FABIUS GS PREMIUM. Dräger. Technology for Life

Innovating with you Shaping exceptional care

State-of-the-art anesthesia technology

User Guide and Operating Manual

INTEGRUSPSV ANAESTHESIA WORKSTATION USER MANUAL

Installation and commissioning instructions 255 series and 256 series

Warning: NEVER ALTER TEST EQUIPMENT

Dialflow Regulator. Instructions for Use

Fabius plus. The plus that makes all the difference. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

The centerpiece of a comprehensive anaesthesia workstation

Reclaim Basic Set Up

VETROSON. OXY-GEN SYSTEMS (Oxygen Generating Systems) Question & Answer Brochure

Helium-Oxygen Blender

Narkomed M Anesthesia System Part No

NARKOVET ANAESTHETIC UNIT

Errors in Monitoring. BWH Clinical Conference 10/06/04. Copyright 2004, James H Philip, all rights reserved.

Oxygen Dialflow Meter. Instructions for Use

Your patients, our primary focus

Statement. Aeonmed have the rights to replace any content in this manual without notice.

Micro Dial-Flowmeter. Instructions for Use

O-Two Self-Study Guide. Equinox Relieve

1 Exam Prep NFPA 99 Health Care Facilities Questions and Answers (Plumbing Contractor)

2011 Equipment Catalog

VT900A + VAPOR. Technical data. One Solution. Auto-detection to Ensure Patient Safety. Key benefits and features

SERVICE KITS AND CALIBRATION NOTES

SIGNET 615 ANAESTHESIA WORKSTATION USER MANUAL

IV-ANE. User s Manual. Anesthesia equipment for test animals. Petition

Yoke Block Instruction Manual

Parker Hannifin Corporation Porter Instrument Division 245 Township Line Road Hatfield, PA USA Tel: Ref Rev.

New product release. Universal Rebreather Monitor (URBM) Three cell / Independent backup

STANDARD FLOWMETER USER S MANUAL

Pressure Regulator. Instructions for Use

Compact Triple Cabinet Outlet Station Model B Installation and Operating Instructions

Compact Triple Cabinet Outlet Station Model Installation and Operating Instructions

Selecting and Connecting Breathing Systems

Nitrous Oxide / Oxygen FLOOR MOUNTED OUTLET STATION Installation and Instructions

Comparison Of The Efficacy Of Two Low Fresh Gas Flow Techniques In Low Flow Anaesthesia

AIR/OXYGEN BLENDER INSTRUCTION MANUAL

STANDARD OPERATING PROCEDURES DIVISION OF COMPARATIVE MEDICINE UNIVERSITY OF SOUTH FLORIDA

R409 Plus Veterinary Ventilator Machine

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model 50 Systems Outfitted with ABM-725 Monitor C O M P A N Y

3:1 High Ratio Oil Pump W. Extn. Kit

Kinetics of Inhaled Anesthetic Agents

Transcription:

Anes Machine Use and Pre-use Check - CA1 focus BWH Anesthesia Grand Rounds August 31, 2005 James H. Philip, MEE, MD, CCE Copyright 2000-2005, James H Philip, all rights reserved

BWH Anesthesia Workspace

The Anesthesia Delivery System Continuous Flow Machine for Gas Mixing and Vaporization Breathing Circuit to provide for breathing and CO2 elimination

Continuous Flow Machine for Gas Mixing and Vaporization Provides continuous flow of - Oxygen for Life Air to safely lower F I O 2 Nitrous Oxide for partial anesthesia Agent vapor for complete or partial anesthesia

N 2 O N 2 O SERVICE INLET 55 psi SIMPLIFIED ANESTHESIA MACHINE SCHEMATIC DIAGRAM No Oxygen safety features N 2 O 750 psi N 2 O FILTER N 2 O N 2 O 750 psi CHECK VALVE 35 psi PRESSURE REGULATOR S CALIBRATED VAPORIZERS I D WALL NEEDLE VALVE O 2 2000 psi O 2 NEEDLE VALVE O 2 [Anesthetizing gases flow] Fresh Gas Flow (FGF) DISS diameter index safety system CONNEC- TION O 2 2000 psi 35 psi OXYGEN FLUSH VALVE [first] Oxygen Flush Flow (last) COMMON OUTLET FRESH GAS HOSE O 2 O 2 SERVICE INLET 55psi

SIMPLIFIED ANESTHESIA MACHINE SCHEMATIC DIAGRAM N 2 O N 2 O SERVICE INLET 55 psi N 2 O 750 psi N 2 O FILTER FAILSAFE VALVE N 2 O N 2 O 750 psi CHECK VALVE 35 psi PRESSURE REGULATOR S CALIBRATED VAPORIZERS I D WALL NEEDLE VALVE O 2 2000 psi O 2 ON/OFF SWITCH NEEDLE VALVE O 2 [Anesthetizing gases flow] Fresh Gas Flow (FGF) DISS diameter index safety system CONNEC- TION O 2 2000 psi 35 psi OXYGEN FLUSH VALVE [first] Oxygen Flush Flow (last) COMMON OUTLET FRESH GAS HOSE O 2 O 2 SERVICE INLET 55psi

N 2 O N 2 O SERVICE INLET 55 psi SIMPLIFIED ANESTHESIA MACHINE SCHEMATIC DIAGRAM GEDO (GE-Datex-Ohmeda) Chain Link 25 for Delivered O 2 Modulus 2+, Aestiva N 2 O FILTER FAILSAFE VALVE N 2 O CHECK VALVE 35 psi PRESSURE REGULATOR S CALIBRATED VAPORIZERS I D WALL DISS diameter index safety system CONNEC- TION O 2 2000 psi O 2 1000-2000 PSI Is OK 35 psi ON/OFF SWITCH 3:1 OXYGEN FLUSH VALVE [first] NEEDLE VALVE Mechanical Stop 0, 50 or 250 ml/min O 2 [Anesthetizing gases flow] Oxygen Flush Flow (last) Fresh Gas Flow (FGF) COMMON OUTLET FRESH GAS HOSE O 2 O 2 SERVICE INLET 55psi

N 2 O N 2 O SERVICE INLET 55 psi SIMPLIFIED ANESTHESIA MACHINE SCHEMATIC DIAGRAM Draeger ORMC = Oxygen Ratio Monitor/Controller Fabius, Tiro, Narkomed MR N 2 O FILTER Linear Regulator N 2 O CHECK VALVE 35 psi PRESSURE REGULATOR S CALIBRATED VAPORIZERS I D WALL NEEDLE VALVE O 2 O 2 ON/OFF SWITCH [Anesthetizing gases flow] Fresh Gas Flow (FGF) DISS diameter index safety system CONNEC- TION O 2 2000 psi 1000-2000 PSI Is OK 35 psi Bypass Flow 0, 50 or 250 ml/min OXYGEN FLUSH VALVE [first] Oxygen Flush Flow (last) COMMON OUTLET FRESH GAS HOSE O 2 O 2 SERVICE INLET 55psi

Continuous Flow Gas Machine N O 2 Air O 2 L/m 9 8 7 6 5 4 3 2 1 0 L/m 9 8 7 6 5 4 3 2 1 0 L/m 9 8 7 6 5 4 3 2 1 0 ml/m 900 600 400 300 200 100 50 1 2 3.. Isoflurane Sevoflurane Desflurane Vaporizer Common Outlet FGF (Fresh Gas Flow)

Ohmeda Modulus 2+

GEDO Modulus 2 SE

Draeger Narkomed MRI-2

Draeger Fabius with Real Needle Valves, Virtual Flowmeters

Direct-reading temperature-compensated Vaporizers Sevo Iso Des

Performance curve, Tec 4, 5, 7 % isoflurane 6 5 4 3 2 1 Dial Setting 5 4 3 2 1 0 0 2 4 Flow rate (L/min O 2 ) 6 8 10

GE-Datex-Ohmeda Aestiva Draeger Fabius GS Two Companies

Breathing Circuit & CO 2 Absorber Schematics

Breathing Circuit & CO 2 Absorber Pictures

GEDO Aestiva CO2 Absorber

Machine Check Out Calibrate Oxygen Monitor Check Machine for gas delivery Check Circuit for integrity Check Ventilator for function Check Exhaust for function

Calibrate Oxygen Monitor Oxygen Monitor switched on, sensor in air 3 minutes, hole plugged. Calibrate to read 21%. Reconnect Oxygen sensor to inspired limb of breathing circuit This is called Circuit Oxygen

Aestiva O2 Sensor in Air for Cal

Fabius O2 Sensor in Air for Cal

Beware of missing sensor

Some have obvious label (good) not Fabius, yet

Expose sensor to air

Ohmeda CD - Calibrate Oxygen System Cal More

Tell machine to calibrate to 21%

Datex Capnomac Ultima Similar Calibration

Fabius

Aestiva

Check Machine for Gas Delivery Machine On Oxygen flows smoothly Disconnect oxygen hose Oxygen alarm sounds Switch ON oxygen tank Verify P > 1000 psi and Alarm silences Check Vaporizer is present and not empty *

Switch ON oxygen tank (with tank wrench)

Check that P > 1000 psi

Other ADSs

Check Machine for Gas Delivery 2 Tank off with wrench Turn oxygen flow up Alarm sounds on oxygen failure Connect oxygen hose to silence alarm Turn up nitrous oxide and observe alarm and/or control Perform negative pressure leak test now (possibly shown later when it makes sense)

Ensure there is no leak - Check circuit for integrity

Check Circuit for integrity Attach circuit including reservoir bag Occlude "Y" with thumb Flush and fill bag to P = 30 cmh 2 O

Check Circuit for integrity Attach circuit including reservoir bag Occlude "Y" with thumb Flush and fill bag to P = 30 cmh 2 O Ensure there is no leak Observer for 10 seconds Pressure should not fall

Check Circuit for integrity Attach circuit including reservoir bag Occlude "Y" with thumb Flush and fill bag to P = 30 cmh 2 O Ensure there is no leak Test pressure alarms Continuing pressure alarm 12 cmh 2 O for > 20 seconds High pressure alarm > 60 cmh 2 O

Check Circuit for integrity Attach circuit including reservoir bag Occlude "Y" with thumb Flush and fill bag to P = 30 cmh 2 O Ensure there is no leak Test Pressure Alarms Open Relief (APL, pop off) Valve Verify Reservoir bag empties

Check Circuit for integrity Attach circuit including reservoir bag Occlude "Y" with thumb Flush and fill bag to P = 30 cmh 2 O Ensure there is no leak Test Pressure Alarms Open Relief (APL, pop off) Valve Verify Reservoir bag empties Observe waste gas collector (scavenger) bag fills and empties

Leak and Compliance tests Automated on Draeger Fabius and Tiro Discussed a bit in next hour

Ensure that you can ventilate By hand with reservoir With mechanical ventilator

Check Waste Gas Collection System

Waste gas collector fills when reservoir bag empties Empties into evacuation system (Scavenger)

Check Scavenger Valves + -

Newer ADSs have Vacuum Gauge and Vacuum Adjustment

We missed one potential leak Low pressure system upstream of breathing circuit Negative Pressure Leak Test

Negative Pressure Leak Test Is not necessary if there is no valve Is not possible if no hose connector Perform only with GEDO (Ohmeda) Modulus 2+

Check Ventilator for function Ventilate reservoir bag Observe no volume loss

Check Suction for Function Rarely used emergently Very important when it is needed

Workspace Setup MRSMAID Machine Room Suction Monitors Airway I V Drugs Suction off if: DISS hose unscrewed Wall switch off Hose disconnect from Canister Canister switch off Insert seated incorrectly Any hole open Flap valve closed because unit was shaken or canister is full Flexible hose kinked Flexible hose stepped on

GE-Datex-Ohmeda Aestiva Draeger Fabius GS Two Companies

Draeger Fabius GS System Test Software, internal hardware Cal Flow, Calibrates the flow sensor Later, compensate for Des high specific heat Cal O2 FIO2 Monitor like all others - expose to air Leak Test Unique to this machine Automatic computation of leak and circuit compliance Press leak test button and follow directions: seal circuit, fill circuit, measure leak&compliance

All this is on Anesthesia Department Web Site http://etherweb.bwh.harvard.edu/ http://etherdev.bwh.harvard.edu/etherweb/education/resources/overview.php Navigate to resources All checkouts are there Special thanks to Anes IS Team Jamie Bell, Dan Holtzman, Fred Donovan, Athena Dimas, and new Director, Bob Gimlich

Technology Matters! I have done what I can to prepare you for your future It is up to you to learn to use your tools as a true expert The resources are available The rest is up to you

Thank you