D-OptoLogger Dissolved Oxygen Logger Operation Manual

Similar documents
D-Opto Dissolved Oxygen Sensor Operation Manual

D-Opto Dissolved Oxygen Sensor Operation Manual for the D-Opto 4-20mA

D-Opto. Dissolved Oxygen Sensor. Operation Manual (Software Version 1.0)

OPERATION MANUAL DIVE CALIPER NOT SCALE / IF IN DOUBT ASK* *ALL UNITS IN MM/DEGREES UNLESS SPECIF. Dive Caliper General DC-051

Optical Dissolved Oxygen Meter

Bante821 Portable Dissolved Oxygen Meter Instruction Manual

Optical Dissolved Oxygen Meter

Instruction Sheet. Important Note: Information that requires special emphasis. Note: Information that supplements points in the main text.

Aerobic Respiration. Evaluation copy

Bante820 Portable Dissolved Oxygen Meter Instruction Manual

Heavy Duty Dissolved Oxygen Meter

Onset Computer Corporation Inside this package: HOBO U20 Water Level Logger Calibration Certificate

Bante810 Benchtop Dissolved Oxygen Meter Instruction Manual

HOBO U20 Water Level Logger (U x and U x-Ti) Manual

DOscan10 Pocket Dissolved Oxygen Tester Instruction Manual

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

NEULOG OXYGEN LOGGER SENSOR GUIDE

HOBO U20L Water Level Logger (U20L-0x) Manual

BI-680 Online Dissolved Oxygen Controller Instruction Manual

Oxygen Meter User Manual

The Oxygen Sensor can be connected to all types of einstein Tablets, einstein LabMate, and einstein LabMate +.

Oxygen Sensor with Electrode

A180 DO/BOD/OUR/SOUR Meter Instruction Manual

HOBO MX Water Level Logger (MX2001-0x) Manual

INSTRUCTION MANUAL. 840 Transmitter. Loop Powered Dissolved Oxygen Transmitter

Evaluation copy. Interdependence of Plants and Animals. computer OBJECTIVES MATERIALS

Instruction Manual. BZ7002 Calibration Software BE

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

BUYER S GUIDE AQUAlogger 530WTD

PRODUCT SHEET. Order probe only as RXPROBE02

TEL/jlRE" Introduction. Display Features and Modes. Startup Procedure. Power-Up Procedure. Adjustment Modes

Dissolved Oxygen/Temp Waterproof Tester

Read this first. Zetasizer nano series Self installation and Quick start guide MRK825-02

Mini-Pro CO2 Sensor User s Manual - ANALOG MODEL -

Section 1: Overview... 6 Features... 6 Supported Software Part 1: Getting Started 7

ELIMINATOR COMPETITION DRAG RACE Program Manual Firm Ver 4.11

LogIT Dissolved Oxygen Probe

OxyScan Graphic. Operating Instructions. UMS Micro-oxygen sensor 501. Microprocessor instrument

Dissolved Oxygen in Water. Evaluation copy. Table 1. Temperature Range ( C) Trout Smallmouth bass Caddisfly larvae

Aqua-DP. Aqua-DP Waterproof Dissolved Oxygen - ph -mv Temperature Meter. TPS Australia - Quality hand-made instruments since 1968.

New product release. Universal Rebreather Monitor (URBM) Single O2 cell and Dual HP package

STARLOG. Capacitive Water Depth Probe

MP15 Jockey Pump Controller

Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter

5 Function Indicator. Outside Air Temperature (C) Outside Air Temperature (F) Pressure Altitude Density Altitude Aircraft Voltage STD TEMP SL 15000

Methods for Measuring Groundwater Elevation and Vacuum Pressure During Soil Vapor Extraction

SHIMADZU LC-10/20 PUMP

CONSUMER MODEL INSTALLATION GUIDE

DM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

SCIENTIFIC DATA SYSTEMS, INC. Depth Tension Line Speed Panel. DTLS Manual

Experiment C-6 Gas Solubility

RDO Optical Dissolved Oxygen Sensor

Bante904 Benchtop Conductivity/Dissolved Oxygen Meter Instruction Manual

MicroTim XB. User Manual. Precision Digital Barometric Altimeter / Barometer / VSI. Document Revision 1.0 Firmware Version 3.0

ETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. Type: ETd 04. class 0.05

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

Met One E-BAM Particulate Monitor

MASK INTEGRITY TEST ACCESSORY (MITA) MODEL 8120

QUICK START GUIDE TO DRINKING WATER MONITORING

DT 630 ALTIMETER, BAROMETER AND COMPASS WATCH OPERATING INSTRUSTIONS

PC Configuration software for Discovery MkVI v 1.03 User guide

ACV-10 Automatic Control Valve

Q2: Which instruments are necessary for monitoring the groundwater level?

HUMOR 20. High-precision Humidity Calibrator HUMOR 20. Operation

Setting Up the Ingenico isc250 Pinpad via USB

Dissolved Oxygen Sensor

Setting up the Ingenico isc250 Pinpad via USB in Windows 8

Deploying the TCM-1 Tilt Current Meter in an Inverted (Hanging) Orientation By: Nick Lowell, Founder & President

Diver-Pocket Diver-Pocket Premium

Sensoric 4-20 ma Transmitter Board Operation Manual

Technology. In the My Files [My Files] submenu you can store all the programs that you have made on the NXT or downloaded from your computer.

Race Screen: Figure 2: Race Screen. Figure 3: Race Screen with Top Bulb Lock

Blood Parameter Monitoring System 550

Altimeter and Compass Watch Instruction Manual

Triton DO8 Dissolved Oxygen Sensors ELECTRO-CHEMICAL DEVICES

HI 2314 HI 2315 HI 23151

WL16 WATER LEVEL LOGGERS Submersible pressure transducer and USB datalogger combination

Pneumatic high-pressure controller Model CPC7000

HOBO MX Water Level Logger (MX2001-0x) Manual

FOOD INTAKE MONITOR. Hardware and Software User s Manual DOC-047 Rev 3.0. Copyright 2009 All Rights Reserved

PRELIMINARY DATASHEET

Quick Start Guide. A. Hardware installation B. Software installation C. Start the software for the first time D. Do your first measurement

SDM-2012 Docking Station Standalone Configuration Operator s Manual

Digital Vacuum Regulator

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

In Response to a Planned Power Outage: PPMS EverCool II Shut Down and Re-start Procedure

HS Bubbler Technology. HyQuest Solutions New Zealand User Group August 2017

Three Lakes Association Hydrolab for Dummies. Table of Contents:

FLUORESCENCE DETERMINATION OF OXYGEN

Membrane covered optical CO 2 sensor

STERILIZABLE DISSOLVED OXYGEN SENSORS

DPC-30 DPC-100. Reference Manual

DDR Dive Data Recorder Manual - Rel /12

Diver-Office. Getting Started Guide. 2007, Schlumberger Water Services

Overview. Front Panel: Keypad and Display

Revision: 23 March 2008 (nk)

OC Panel High Limit Aquastat Kit, Manual Reset p/n

Instruction Manual HI Portable Waterproof Dissolved Oxygen Meter.

SENSUS PRO MANAGER (for SENSUS or SENSUS PRO devices) User s Guide -- Windows. Version 2.0 Published October 17, ReefNet Inc.

APA software instruction manual

Transcription:

D-OptoLogger Dissolved Oxygen Logger Operation Manual Software version 3.4

Contents 1. Introduction..... 1 Optical Sensor Technology.....1 Features...... 1 2. D-OptoLogger Specifications.2 Specifications... 2 Communication Cable Wiring Scheme... 2 3. Software..3 Installation.. 3 Operation. 4 4. Operating the D-OptoLogger... 9 Installation.....9 Sealing the D-OptoLogger... 9 Logging Endurance... 10 Calibration... 11 5. Maintenance.... 13 6. Troubleshooting.. 14 Interpreting the LED indicator 14 Loss of communication 14 Zero value data. 14 Erractic dissolved oxygen readings. 14 7. Appendices.... 15 Appendix 1: Pressure Correction Chart... 15 Appendix 2: Useful Conversions...16 8. Further Assistance... 17

1. Introduction The D-OptoLogger is a fully self-contained dissolved oxygen logger incorporating a dissolved oxygen sensor, battery and low power data logger in a rugged compact underwater housing. The D-OptoLogger uses a field-proven solid-state optical sensing system to measure dissolved oxygen. It is highly stable over long periods of time, even in harsh conditions. The data is stored onboard in nonvolatile memory. The D-OptoLogger is setup and data offloaded using simple Windows based software supplied with the instrument. Optical Sensor Technology Unlike conventional dissolved oxygen sensors, the D-OptoLogger sensing element utilizes fluorescence to measure dissolved oxygen. The basic principle involves subjecting a fluorescing compound (ruthenium) to a fixed wavelength of light. When the light source is removed, the compound emits a fluorescence, the intensity of which is dependent on the oxygen levels present in the surrounding water. An extremely stable electronic circuit has been designed to firstly excite the ruthenium and then measure the intensity of the resulting fluorescence. Using this circuitry, the D-OptoLogger should provide accurate dissolved oxygen measurements over many months without re-calibration. Unlike conventional polarographic dissolved oxygen sensors, the optical method does not consume oxygen. Consequently the measurement of dissolved oxygen by the D-OptoLogger is unaffected by water movement. Also the D-OptoLogger does not utilize a membrane or any other consumables, thus minimizing servicing requirements. Features Your D-OptoLogger offers the following features: Accurate dissolved oxygen measurements over long periods without re-calibration Low power consumption data logger Windows based communication software Minimal servicing requirements 1

2. D-OptoLogger Specifications Specifications Physical Dimensions Accuracy Resolution Sensor Drift Power Supply Power Consumption Memory Capacity Temperature: DO: Temperature: DO saturation: PPM 200mm long x 50mm diameter +/- 0.1 degrees C 1% of reading or 0.02 PPM, whichever is greater 00.01 degrees C 000.01% 00.001 PPM <1% per year (provided measurement interval 10 minutes) 1 x PP9-9 volt alkaline battery. Duracell or Energizer recommended 12 ma during measurement, 0.03 ma between measurements 10080 data records. Each data record consists of date, time, battery voltage, temperature, dissolved oxygen % saturation, dissolved oxygen PPM Depth Rating Maximum 30m water depth O Rings 2 of #128 (1½ x3/32 ) TABLE 1: D-OPTOLOGGER SPECIFICATIONS Communication Cable Wiring Scheme 2

3. Software The D-OptoLogger is supplied with the custom designed Windows based communication software program D-OptoLog. This software: Enables the user to communicate with the D-OptoLogger via a computer Is used to setup the D-OptoLogger prior to deployment Is used to download data from the D-OptoLogger to the PC after retrieval Installation The D-OptoLogger is supplied with a software CD that contains the file Install D-OptoLogX.exe (X = version number). Double clicking the file from Windows Explorer will initiate installation onto the PC. The default installation destination is C:\Program Files\D-OptoLog. It is recommended that this destination is accepted. This will result in the correct installation into the appropriate folders for either XP or Vista operating systems. 3

Operation The D-OptoLogger is supplied with a communication cable. This cable has a 9-pin serial plug on one end and a 3.5mm jack plug on the other end. The 9-pin plug is plugged into the serial port on the PC. If the PC does not have a serial port, a USB to serial adaptor can be used. This adaptor plugs into the USB port on the PC and has a serial port that the communication cable 9-pin plug can be plugged into. The jack plug on the communication cable is plugged into the communication socket located inside the D-OptoLogger housing. This is accessed by removing the D-OptoLogger end cap. When D-OptoLog is started and the current port is unavailable, a port selection window opens (Figure 1). FIGURE 1: D-OPTOLOG SERIAL PORT SELECTION WINDOW If the computer has a hardware serial port, it will typically be Com 1. If a USB to serial converter is being used, the com port number will most likely be another number. To determine the correct com port number when using a USB to serial converter it is necessary to open the Device Manager. In Vista, the device manager can be opened directly from the Control Panel. With XP, first open Control Panel, then open the System folder, click on the Hardware tab and then click on the Device Manager button. Once you have opened Device Manager, click on Ports (COM & LPT) to extend the tree. The com port number for the USB to serial converter will be displayed. Control Panel System Hardware Device Manager Ports (COM & LPT) 4

In the example in Figure 2, the com port is Com 4. FIGURE 2: DEVICE MANAGER NOTE! The com port number assigned to the USB serial converter may change between computer re-starts. 5

Once the correct port has been selected and the OK button pressed, the computer will start communicating with the D-OptoLogger. This may take up to 8 seconds. When communication has started the D-OptoLog main window will open (Figure 3). FIGURE 3: D-OPTOLOG MAIN WINDOW The main window displays current dissolved oxygen (% saturation and PPM) and temperature ( C) data and is updated approximately once every second. The serial number displayed is factory set and is unique to each D-OptoLogger. It corresponds to the number displayed on the outside of the D-OptoLogger housing. The logger setup section enables the operator to set the desired logger parameters. 6

The Plot data button enables a graphical plot of historic D-OptoLogger data to be displayed on screen (Figure 4). FIGURE 4: PLOT DATA SCREEN The Calibrate button opens the D-OptoLogger Calibration window (Figure 5). All calibration values are calculated and stored internally by the D-OptoLogger. The Restore Defaults button causes the D- OptoLogger to resort back to the original factory calibrations. A full description of the calibration procedure is outlined in the Operating the D-OptoLogger section. FIGURE 5: D-OPTOLOGGER CALIBRATION WINDOW 7

The Altitude Correction button opens up the Pressure Correction Calculator which provides a tool for pressure correcting the dissolved oxygen saturation content of fully aerated water (Figure 6). It will accept either altitude (m) or barometric pressure (mbar). NOTE! By pressing the Restore Defaults button, the original factory calibration values are reinstated by the D-OptoLogger. FIGURE 6: PRESSURE CORRECTION CALCULATOR 8

4. Operating the D-OptoLogger Installation The D-OptoLogger can be mounted in any orientation. The body can be clamped in position. Avoid using excessive force. A safety wire can be attached to the eyelet swivel on the top cap of the logger. It is not recommended that the D-OptoLogger is suspended solely from the eyelet swivel. NOTE! A new battery should always be used when starting a deployment. Use good quality alkaline batteries such as Duracell or Energizer. Sealing the D-OptoLogger The D-OptoLogger end cap features a dual O ring sealing system. It is essential that these O rings are properly serviced and maintained, otherwise moisture may penetrate the housing. The O rings must be cleaned and lubricated each time the end cap is replaced prior to underwater deployment. 1) Using the O ring pick supplied, remove the O rings from the inside of the end cap and the body of the D-OptoLogger. 2) Using a lint free tissue, clean the O ring seats, the corresponding O ring surfaces and both O rings. 3) Lightly grease both O rings with the grease supplied with your D-OptoLogger. 4) Replace the O rings, ensuring no hairs or particles become trapped under them. 5) Screw the end cap onto the D-OptoLogger body. Do not over tighten. 9

Logging Endurance The D-OptoLogger can log 10,080 data records into non-volatile memory. Each data record consists of the time and date, battery voltage, dissolved oxygen percent saturation, PPM and temperature (See Table 2). Data Field Number: 1 Year Description: 2 Month 3 Day 4 Hour 5 Minute 6 Second 7 Battery voltage 8 Temperature (Degrees C) 9 Dissolved Oxygen (%) 10 Dissolved Oxygen (PPM) TABLE 2: DATA FILE FORMAT Data is retained in the non-volatile memory until a new logging session is started, at which point the memory is cleared of the previous data. Memory logging endurance for different logging intervals are shown in Table 3. Logging Interval (minutes): Memory Endurance (Days): 1 7 5 35 10 70 15 105 30 210 60 420 TABLE 3: MEMORY ENDURANCE NOTE! In reality battery power may limit the deployment duration, not memory capacity. The D-OptoLogger will operate until the battery voltage drops below around 7.0 volts. If this occurs while the D-OptoLogger is in logging mode, the last set of data values in the data file will be set to zero and the D-OptoLogger enters a low power sleep mode with no further data values being logged. 10

Calibration Under normal operating conditions the D-OptoLogger should require only infrequent calibration. Calibration of the D-OptoLogger is a simple operation that can be performed in the field. Due to the measurement principle of the D-OptoLogger, performing air calibrations is not advisable. NOTE! When calibrating the D-OptoLogger, do not allow water to enter into the instrument. The offset and gain of the D-OptoLogger are calibrated individually. Normally only the offset will need to be calibrated as the gain is more stable than the offset over time. NOTE! The gain should be calibrated only AFTER the offset has been calibrated. FIGURE 7: D-OPTOLOGGER CALIBRATION WINDOW 11

Offset Calibration A reference solution of 0% dissolved oxygen is required for the offset calibration. This can be created by mixing a couple of teaspoons of sodium sulfite into 1 litre of distilled or fresh tap water. Procedure: 1) Place the D-OptoLogger in the reference solution and allow it to equilibrate for at least 30 minutes. 2) Power up the D-OptoLogger and start D-OptoLog. Once the measurements have stabilized, press the Calibrate button in the main window. 3) Enter 0 (zero) in the offset calibration edit box and press the Reset offset button. 4) The D-OptoLogger performs a calibration routine followed by a self-check; this can take up to 30 seconds. Do not remove the D-OptoLogger from the reference solution during this period. The operator will be notified when the process is complete. Gain Calibration A solution of known dissolved oxygen content, other than 0%, should be used for the gain calibration. The most practical method is to create a fully aerated solution. This can be done by bubbling air through a container of distilled or fresh tap water, stirring frequently. After around 30 minutes, the water can be assumed to be fully saturated. The actual dissolved oxygen saturation can be calculated by correcting for altitude, or preferably, the local barometric pressure if that is known. The Correction Calculator can be used to calculate the corrected dissolved oxygen content of the fully aerated reference solution. As an example, if the D-OptoLogger is installed at a field site at 435 meters above sea level, and a fully aerated reference solution is prepared on site, the actual dissolved oxygen percent saturation is calculated at 95%. (See Appendix 1) Procedure: 1) Place the D-OptoLogger in the reference solution and allow it to equilibrate for at least 30 minutes. 2) Power up the D-OptoLogger and start D-OptoLog. Once the measurements have stabilized, press the Calibrate button in the main window to open the Calibration window. 3) Enter the pressure corrected dissolved oxygen percent saturation of the reference solution in the gain calibration edit box and press the Reset span button. 4) The D-Opto performs a calibration routine followed by a self-check; this can take up to 30 seconds. Do not remove the D-OptoLogger from the reference solution during this period. The operator will be notified when the process is complete. 12

5. Maintenance As with all instruments, it is good operating practice to make regular checks on the quality of data being generated by the D-OptoLogger. This can be carried out on site using one of the following two methods: 1) Place a recently calibrated transportable dissolved oxygen sensor next to the D-OptoLogger and compare the measurements. It is important to allow a sufficient period of time for temperature equilibration to occur. 2) Place the D-OptoLogger in a solution of known dissolved oxygen content. A solution of 0% dissolved oxygen saturation can be created by adding a few teaspoons of sodium sulfite to 1 litre of distilled or fresh tap water. The D-OptoLogger can tolerate some biofouling, however steps should be taken to minimize this where possible. For example, covering the D-OptoLogger can reduce the amount of bio-growth by restricting available light. The copper biofouling control ring should reduce bio-growth in the area around the optical window; this ring is sacrificial and may require replacement on an occasional basis. Periodically it may be necessary to clean the D-Opto optical window to remove bio-growth or other accumulated deposits. Use warm soapy water to clean the D-OptoLogger. NOTE! DO NOT use a hard object to clean the optical window as this may scratch or damage it. Only use the cleaning pads supplied with the D-Opto. 13

6. Troubleshooting Interpreting the LED indicator The LED indicator inside the D-OptoLogger housing, next to the battery and communication socket, can be used to identify the D-OptoLogger s current status. The interval between the flashing sequences may be up to 8 seconds. LED Blink Sequence: One flash Two flashes Three flashes Four flashes Five flashes Status Description: Operational Delayed start Not operational, waiting for PC communications Memory full Low battery shut down TABLE 4: LED FLASH SEQUENCE CODES Loss of communication If the PC starts to communicate with the D-OptoLogger, but then loses communication, replace the D- OptoLogger battery. If the D-OptoLogger is not communicating with the PC: Check the battery voltage. Check the communications cable is plugged into the correct serial port on the PC. Zero value data If the last data record in the data file consists of zero values the D-OptoLogger battery dropped below around 7 volts and needs replacing. Erratic dissolved oxygen readings You may encounter occasions when the dissolved oxygen readings are highly erratic, but the temperature readings are stable. The D-OptoLogger incorporates a high gain amplification circuit to measure the fluorescence of the optical window. The instrument has been carefully designed to prevent electrical interference impacting on the operation. Under extreme conditions however, noise may become a problem. Track down the source of noise; this could be a nearby pump or other motor. If the D-OptoLogger is being bench tested in a small container of water, noise can be caused by a lack of suitable earthing. Place a grounding wire from the water to the D-OptoLogger power ground. The D-OptoLogger is supplied with built-in noise rejection specific for the country of supply. If the D-OptoLogger is being used in a country other than the country it was supplied to, contact your supplier or Zebra-Tech. 14

7. Appendices Appendix 1: Pressure Correction Chart Altitude (m) Altitude (feet) Barometric pressure (mbar) % Saturation 0 0 1013 100 85 278 1003 99 170 558 993 98 256 841 983 97 343 1126 973 96 431 1413 963 95 519 1703 952 94 608 1995 942 93 698 2290 932 92 789 2587 922 91 880 2887 912 90 972 3190 902 89 1066 3496 899 88 1160 3804 882 87 1254 4115 871 86 1350 4430 861 85 1447 4747 851 84 1544 5067 841 83 1643 5391 831 82 1743 5717 821 81 1843 6047 811 80 1945 6381 800 79 2047 6717 790 78 2151 7058 780 77 2256 7401 770 76 2362 7749 760 75 2469 8100 750 74 2577 8455 740 73 2687 8815 730 72 2797 9178 719 71 2909 9545 709 70 3023 9917 699 69 3137 10293 689 68 15

Appendix 2: Useful Conversions Convert from To Calculation kpa mbar Multiply by 10 inhg mbar Multiply by 33.85 Feet Meters Multiply by 0.3048 Centigrade Fahrenheit C) +32 16

8. Further Assistance For further assistance with this or any other Zebra-Tech product, please contact: Zebra-Tech Ltd PO Box 1668 Nelson 7040 New Zealand Tel: International 0064 3 548 0468 Fax: International 0064 3 548 0466 Email: enquiry@zebra-tech.co.nz For up to date information about the D-OptoLogger and other Zebra-Tech products, please visit the Zebra-Tech Ltd website at: http://www.zebra-tech.co.nz Proudly designed and manufactured in New Zealand 17