Technical Data. Dimensions

Similar documents
Technical Data. Dimensions

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. General specifications. Rated operating distance s n 5 mm

Technical Data. Dimensions

Technical Data. Dimensions

Technical Data. General specifications Switching element function Rated operating distance s n 1.5 mm

Technical Data. Dimensions

Technical Data. General specifications Switching element function Rated operating distance s n 2 mm

Technical Data. General specifications. Rated operating distance s n 2 mm

Technical Data. Dimensions

Technical Data. Dimensions

Technical Data. Dimensions

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 5 mm

Inductive slot sensor

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 10 mm

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

IA CERTIFICATE (Revision 3 Revised for Annual Review) Hazel Grove Stockport Cheshire SK14 6NG United Kingdom

Pressure switch, Differential pressure switch and Thermostat RT-E

LMP 307. Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % / 0.

Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure

Electropneumatic Positioner Type 4763 Pneumatic Positioner Type 4765

RTD temperature probes

Type N-10, N-11 Hazardous Area Non-incendive Transmitters

Technical Datasheet. D Series SMART Pressure Transmitter Model: DPC D-Series. Key Features. Series Overview. Product applications

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/16 Siemens FI US Edition

DK46 - DK800 Supplementary instructions

Pressure Measurement Single-range transmitters for general applications

Level switches Series LD Vibrating fork level switch for liquids and solids

DMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0.

VG5 Supplementary instructions

Operating Instructions

OPTIBAR P 1010 C Technical Datasheet

IA CERTIFICATE (Annual review required by MASC covered by an additional letter) (Revision 2- Review & Review)

SITRANS P measuring instruments for pressure

Level transmitter LT 100

Certificate of Compliance

Level switches Series LD Vibrating fork level switch for liquids and solids

OSAT Series. Intrinsically Safe Infrared Temperature Sensor Operator's Guide

Pressure Switches Application Guideline

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

L (up to 25 m) Electronic part. working temp.: Ñ IP 66 / IP67. Mounting bracket ÐÑ. Sensor type. working temp.:

GA24 Technical Datasheet

VS18/26 with PROFINET and EtherNet/IP Interface. ATEX Installation Instructions

Pressure control, differental pressure control and thermostat Type RT

Relative pressure transmitter type 520

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

Further technical information is available on

Liquid level instruments BM 24 /BM 51

ATM.1ST/Ex - High Precision Transmitter

High-performance submersible pressure transmitter For level measurement Model LH-10

Two-Wire In Situ Oxygen Analyzer (550 to 1400 C)

II 2G EEx ia IIC T6. Ignition protection class

Level sensing relative and absolute pressure transmitter type 712

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

MJK Expert 700 / 800 / 900 / 7070 / 7060 MJK Expert 1400 / 3400

ABTQ-110 rev 00 (Last review: 28 Aug 12) INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS FOR ABTECH S RANGE ENCLOSURES IECEx SIR U SERIAL No

x act i Precision- Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor

ATM.ECO/IS - Analog Transmitter with Temperature compensation

Safety Instructions Liquiphant FailSafe FTL80, FTL81, FTL85

Torque Tube TB300 Digital Transmitters

4/2 way Pneumatic Solenoid Valve

Pressure Measurement Single-range transmitters for general applications

KTE6000 / KTU6000 Series OEM pressure transmitters for industrial media

High-performance submersible pressure transmitter For level measurement Model LH-20

DSL, DSH: Specially designed pressure limiter

Reg No: 1999/027771/07 ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS

LTB013EN. Operating Instruction Trimod Besta Level Switch types XA 5, XB 5 for use in potentially explosive atmospheres acc.

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI US Edition

Hidrostatic Level DATASHEET

High-performance submersible pressure transmitter For level measurement Model LH-20

EX-RECESSED CEILING LIGHT FITTINGS

Miniature flowmeters DK 46, DKR 46 DK 47, DK 48, DK 800

Pressure Measurement Single-range transmitters for general applications

better measurement Simply a question of

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)

Operating Instructions

Siemens AG psi (6 bar) 145 psi (10 bar) 464 psi (32 bar) 1450 psi (100 bar) 3626 psi (250 bar) 8700 psi (600 bar) psi (800 bar)

Two-Wire In Situ Oxygen Analyzer (550 to 1400 C)

Monitoring device NTS 30

Pressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

Manual Power relay SR853

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI

CERTIFICATE OF COMPLIANCE

Operating Instructions

Tightness controls TC 1 3 and TC 4

Pressure switch KP-E. Data sheet

Rosemount 2120 Full-featured Vibrating Fork Liquid Level Switch. Quick Start Guide , Rev BA August 2012

Types and approvals. Page 1/6. Data Sheet

High-performance submersible pressure transmitter For level measurement Model LH-10

Pressure switch with bourdon tube

Supplementary Installation and Operating Instructions. Variable Area Flow Meters SGK-1 Ex SGK-2 Ex SGK-3 Ex. Category: II 2G Ex IIC II 3G Ex IIC

Bourdon tube pressure gauge for diaphragm seals

Transcription:

0102 Model Number Features Comfort series 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories BF 18 Mounting flange, 18 mm EXG-18 Quick mounting bracket with dead stop Technical Data specifications Switching function Normally closed (NC) Output type NAMUR Rated operating distance s n 5 mm Installation flush Assured operating distance s a 0... 4.05 mm Reduction factor r Al 0.21 Reduction factor r Cu 0.18 Reduction factor r 304 0.63 Nominal ratings Nominal voltage U o 8.2 V (R i approx. 1 kω) Operating voltage U B 5... 25 V Switching frequency f 0... 500 Hz Hysteresis H 3 % Current consumption Measuring plate not detected 3 ma Measuring plate detected 1 ma Functional safety related parameters MTTF d 14110 a Mission Time (T M ) 20 a Diagnostic Coverage (DC) 0 % Ambient conditions Ambient temperature -25... 100 C (-13... 212 F) Mechanical specifications Connection type cable PVC, 2 m Core cross-section 0.75 mm 2 Housing material Stainless steel 1.4305 / AISI 303 Sensing face PBT Degree of protection IP66 / IP67 Cable Bending radius > 10 x cable diameter information Use in the hazardous area see instruction manuals Category 1G; 2G; 1D Compliance with standards and directives Standard conformity NAMUR EN 60947-5-6:2000 IEC 60947-5-6:1999 EN 60947-5-2:2007 IEC 60947-5-2:2007 Approvals and certificates FM approval Control drawing 116-0165 UL approval culus Listed, Purpose CSA approval ccsaus Listed, Purpose CCC approval CCC approval / marking not required for products rated 36 V Dimensions M18x1 40 4 24 1

Electrical Connection BN L+ BU L- 2

Equipment protection level Ga Device category 1G for use in hazardous areas with gas, vapour and mist II 1G Ex ia IIC T6 T1 Ga The Ex-related marking can also be printed on the Ambient temperature and in this instruction manual. The EU-type examination certificate has to be observed. The special conditions must be adhered to! ambient temperature, the temperature class, and the effective internal reactance values can be found on the EC-type examination certificate. Note: Use the temperature table for category 1!!! The 20 % reduction in accordance with EN 1127-1 has already been applied to the temperature table for category 1. must be observed. The intrinsic safety is only assured in connection with an appropriate related apparatus and according to the proof of intrinsic safety. The associated apparatus must satisfy the requirements of category ia. Due to the possible danger of ignition, which can arise due to faults and/or transient currents in the equipotential bonding system, galvanic isolation of the power supply and signal circuit is preferable. Associated apparatus without electrical isolation must only be used if the appropriate requirements of IEC 60079-14 are met. If the Exrelated marking is printed only on the supplied label, then this must be attached in the immediate vicinity of the sensor. The sticking surface for the label must be clean and free from grease. The attached label must be legible and indelible, including in the event of possible chemical corrosion. against the effects of impact by installing an additional enclosure. The information regarding the minimum ambient temperature for the sensor as provided in the datasheet must also be observed. s on the metal housing components must be avoided. Dangerous electrostatic charges on the metal housing components can be avoided by incorporating these components in the equipotential bonding. 3

Equipment protection level Gb Device category 2G for use in hazardous areas with gas, vapour and mist II 1G Ex ia IIC T6 T1 Ga The Ex-related marking can also be printed on the Maximum permissible ambient temperature T amb and in this instruction manual. The EU-type examination certificate has to be observed. The special conditions must be adhered to! ambient temperature, the temperature class, and the effective internal reactance values can be found on the EC-type examination certificate. must be observed. The intrinsic safety is only assured in connection with an appropriate related apparatus and according to the proof of intrinsic safety. If the Ex-related marking is printed only on the supplied label, then this must be attached in the immediate vicinity of the sensor. The sticking surface for the label must be clean and free from grease. The attached label must be legible and indelible, including in the event of possible chemical corrosion. against the effects of impact by installing an additional enclosure. The information regarding the minimum ambient temperature for the sensor as provided in the datasheet must also be observed. s must be avoided on the mechanical housing components. Dangerous electrostatic charges on the mechanical housing components can be avoided by incorporating these in the equipotential bonding. 4

Equipment protection level Da Device category 1D for use in hazardous areas with combustible dust II 1D Ex ia IIIC T135 C Da The Ex-related marking can also be printed on the Maximum permissible ambient temperature T amb and in this instruction manual. The EU-type examination certificate has to be observed. ambient temperature, the surface temperature, and the effective internal reactance values can be found on the EC-type-examination certificate. The maximum permissible ambient temperature of the data sheet must be noted, in addition, the lower of the two values must be maintained. must be observed. The intrinsic safety is only assured in connection with an appropriate related apparatus and according to the proof of intrinsic safety. If the Ex-related marking is printed only on the supplied label, then this must be attached in the immediate vicinity of the sensor. The sticking surface for the label must be clean and free from grease. The attached label must be legible and indelible, including in the event of possible chemical corrosion. against the effects of impact by installing an additional enclosure. The information regarding the minimum ambient temperature for the sensor as provided in the datasheet must also be observed. s must be avoided on the mechanical housing components. Dangerous electrostatic charges on the mechanical housing components can be avoided by incorporating these in the equipotential bonding. Do not attach the nameplate provided in areas where electrostatic charge can build up. 5