Selection of ICF made easy Save even more time with ICF

Similar documents
Capacities Valve Station, type ICF 15, 20, 25

Valve station ICF 15, ICF 20, ICF 25, ICF 50 and ICF 65

Instructions. Control Solution ICF 20-4, ICF 25-4, ICF ICF 40-4, ICF 20-6, ICF 25-6, ICF 32-6, ICF 40-6, Direction and position.

80% Less installation time with just two welds for fast and efficient installation.

Instructions. Control Solution ICF 20-4, ICF 25-4, ICF ICF 40-4, ICF 20-6, ICF 25-6, ICF 32-6, ICF 40-6, Direction and Position.

Valve Station ICF 15, 20 and 25

80% Less installation time with just two welds for fast and efficient installation.

36% higher capacity than market alternatives. New ICF 50-4 and ICF 65-3: A great valve family just got greater.

Solenoid Valves, one - or two step, on/off ICLX

Dual position solenoid valve Type ICSH 25-80

Pilot valves for pilot operated servo valves

2-step solenoid valve Type ICLX

2-step solenoid valve Type ICLX

Solenoid valves, two-step on/off Type PMLX REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Gas powered stop valves, type GPLX REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Overflow valves Type OFV REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Evaporating Pressure Regulating Valve Type KVQ REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Modulating liquid level regulators, servo-controlled PMFL / PMFH and SV

Overflow valves Type OFV Type OFV-SS REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Electric regulating valves Type CCMT 2 - CCMT 8 / CCMT 16 - CCMT 42

Float valves Types SV 4, SV 5 and SV 6

DANFOSS VALVE CONFIGURATIONS BULLETIN DC-SB14-02

Liquid level regulating valves Types PMFL / PMFH and SV

Pressure regulating valves Types OFV, OFV-SS

Shut-off Liquid level and regulating valves for for Industrial Refrigeration

Electric expansion valves Types AKV 10, AKV 15 and AKV 20

Modulating liquid level regulators, direct-controlled, type SV 1 and 3 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Float valves Types SV 1 and SV 3

Regulating valves Type REG 6-65 Type REG-SS REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Liquid level glasses, type LLG REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Regulating valves REG-SA and REG-SB

Solenoid valve type EVR for Hydrocarbons

Capacity regulator (hot gas bypass)

Hand operated regulating valves Types REG-SA and REG-SB

Capacity regulator (hot gas bypass), type TUH/TCHE/TRHE REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Industrial Refrigeration Control Valves. Catalog C12-PVS Parker Valve Station (PVS) Sizing Guide

Technical leaflet. Pressure and Temperature Regulators. January 1999 RC.4X.B1.22. Danfoss A/S

MAKING MODERN LIVING POSSIBLE. Pilot operated internal safety valves type POV REFRIGERATION AND AIR CONDITIONING DIVISION.

Nugget 120 V14 Series

Crankcase pressure regulator, type KVL REFRIGERATION AND AIR CONDITIONING. Technical leaflet

2/2-Way Solenoid Control Valve

Nugget 120 V14 Series

Semi-Hermetic compact screw compressors

Condensing pressure regulator, type KVR Differential pressure valve, type NRD

SPOOL VALVES. pilot operated single/dual solenoid (mono/bistable function) ISO mm - pad mounting body M12 connection

Ball Float Steam Trap UNA 45 MAX, UNA 46 MAX, UNA 46A MAX PN 40/Class 300 DN 40, 50, 65

Reliable System Performance PM valves

Hand-operated regulating valves in stainless steel Types REG-SA SS and REG-SB SS

Quick closing oil drain valve, type QDV 15 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Leak-Free Load-Control Valve SAE ½ psi flange

CROT-6 CROT-10 CRO-4. for Compressor Overload Protection

WaterSource Heat Pump Hose Kit Performance Specification-Summary

CVI Valve Line. Exceeds the industry s highest standards for reliability and performance

Pressure Equipment Directive (PED) 97/23/EC Page 033 of 124

Direct Operated Precision Regulator Modular Style. Standard Specifications

Refrigeration and Air Conditioning Technical leaflet

Tightness controls TC 1 3 and TC 4

Unit 24: Applications of Pneumatics and Hydraulics

Proportional Pressure-Relief Cartridge Valve, Size 2...4

GM Series Dual-Block Multi-Function Gas Control Valves

Water valve Type WVO. Data sheet MAKING MODERN LIVING POSSIBLE

Dual Modular Safety Shutoff Valves DMV-D 525/11 DMV-DLE 525/11

Safety relief valves SFV 20-25

Solenoid valves VZWF, force pilot operated

Inverse Prop. Pressure-Relief Cart., Size 2 4

Standard Specifications

Sales Office: Danfoss Expansion Valves. T*2 Range Order valve and orifice separately Range N -40 C to +10 C Without MOP

Safety relief valves, type BSV 8 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

94270 Vapor Guard Tank Blanketing Valve Vapor Guard Tank Blanketing Valve What is Tank Blanketing? Features How does it work?

MV-01. Features. 2/2-way Solenoid Valve for Fluids. Description: Application:

Technology issues regarding Blends of Refrigerants Buffalo Research Laboratory

Simple Set Max. Pressure Independent Control Valves 2 Way 2-1/ /09/18

TECHNICAL DATA Q= C. Table 1 - Specifications

Data sheet Pressure switch type CS December 2001 DKACT.PD.P10.A B1119

Dual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure. DMV-D/624L Series DMV-DLE/624L Series

ANDERSON GREENWOOD TANK BLANKETING REGULATORS

2/2-Way Proportional Valve (motor-driven)

Dual Modular Safety Shutoff Valves. DMV-D/602 Series DMV-DLE/602 Series

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL ACCUMULATORS. This work covers part of outcome 2 of the Edexcel standard module:

Dual Modular Safety Shutoff Valves. DMV-D/11 Series DMV-DLE/11 Series

TECHNICAL DATA. Table 1 - Specifications

SERIES 30. Spring Operated Tank Blanketing Valve PROTECTOSEAL.

GENO -Flushing Compressor Product Data Sheet F 02

NGP-250/500 Nitrogen Generator Quick Start Guide

DIAPHRAGM PUMPS WITH KNF STABILIZATION SYSTEM

AE R8 December 2004 Reformatted November Copelametic Two-Stage Compressors Application and Service Instructions

Pressure switch KP-E. Data sheet

OPTIBAR P 1010 C Technical Datasheet

2/2- and 3/2-way Rocker Solenoid Valve - bistable (impulse) version

Data Sheet Issue A

P499 Heavy Duty Pressure Transducer

RIX COMPRESSORS. MICROBOOST Owner s Manual CONFIGURATION A MB-115 MB-230. November 21, 2002 APPLICABILITY [ A]

Pressure controls for hydro carbons, zone II applications, Type KPE

Safety relief valves, type SFA 15 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Dual Modular Safety Shutoff Valves with NEMA 4x Enclosure DMV-D 704/604 DMV-DLE 704/604

Two-port seat valves

Safety relief valves Type SFA 15 and SFA 15-50

Evaporator pressure regulator Type KVP

Aperval Pressure Regulators

Dual Modular Safety Shutoff Valves with Proof of Closure. DMV-D/622 Series DMV-DLE/622 Series

Transcription:

MAKING MODERN LIVING POSSIBLE Selection of ICF made easy Save even more time with ICF ICF stands for valve trains and for over five years installation and service has never been easier. This quick guide provides you with key information to choose the right ICF in common applications such as pumped liquid, hot gas and liquid injection lines. 50% less service time The ICF valve stations are designed to quickly and efficiently evacuate refrigerant during service calls so you can get your product COOL. 80% less installation time Keep productivity up by making two welds instead of 10 or more. Experience better functionality while lowering pressure drops. Quick Selection Guide

Produced by Metaphor, 01-2011

Application Guide Approvals................................................................................................. 5 Technical data............................................................................................. 5 ICF in detail............................................................................................... 6 Flow through the ICF...................................................................................... 6 ICF overview.............................................................................................. 6 Design work with ICF...................................................................................... 8 Standard applications..................................................................................... 9 Pumped liquid line....................................................................................10 Hot gas defrost........................................................................................11 Liquid injection to separator...........................................................................12 Accessories for ICF........................................................................................13 Produced by Metaphor, 01-2011 DKRCI.PA.FT0.A1.22 / 520H5093 3

Produced by Metaphor, 01-2011

Application Guide The valve train of the Future since 2005 The ICF valve station is an innovative solution that provides the full functionality of a conventional valve station in a single compact unit. Eliminate project bottleneck: Conventional valve stations of six or more individual components and up to twelve welds. ICF means two welds directly at the job site Down time during service is reduced to a fraction compared to conventional valve trains. The unique design of the ICF ensures a quick pump down and faster access to valve modules. The ICF valve is a compact valve train ready for the jobsite. This solution provides you with a variety of benefits: Designed for Industrial Refrigeration Supplied fully assembled. No need to disassembly prior to installation under normal welding procedures Standard side ports to fit service valves, pressure transmitters, sight glasses. Applicable to all common non flammable refrigerants including R744 and R717. Direct Weld Connections (No leaks through flanges) Compact design, faster service Available with different connection types including ANSI and DIN, Socket weld High capacities low pressure drop Low weight design Approvals ICF valve station Nominal bore DN 25 (1 in.) DN 32-40 (1¼ - 1½ ) Classified for Fluid group I Category Article 3, paragraph 3 II CRN Technical data Refrigerants Applicable to all common non flammable refrigerants including R717, R744 (CO 2 ) and non corrosive gases/liquids dependent on sealing material compatibility. For further information please refer to installation instruction for ICF. Use of the ICF control solution with flammable hydrocarbons is not recommended. For further information please contact the local Danfoss sales company. Temperature range 60/+120 C ( 76/+248 F). Ambient temperature for ICF with ICAD: 30 C/+50 C ( 22 F/122 F) Surface protection The external surface is zinc-chromated to provide corrosion protection. Additional on-site corrosion protection is recommended. Pressure The ICF is designed for: Max. working pressure: 52 bar g (754 psig) Opening differential pressure Please refer to the individual function module data. Produced by Metaphor, 01-2011 DKRCI.PA.FT0.A1.22 / 520H5093 5

Application Guide ICF in detail The innovative design of the ICF allows for a wide variety of different configurations. Many of the typical necessary configurations have been created as standard code, which makes ordering easy. See other configurations in the complete technical leaflet, DKRCI.PD.FT0 Small frame ICF 20-4 Large frame ICF 20-6 ICF (25-40)-4 ICF (25-40)-6 Flow through the ICF M5 Flow in an ICF 20-6 Flow in an ICF 20-4 M6 M2 M2 ICF overview Valve type Model (example) PS (MWP) [bar] [psig] ICF 20-4 52 754 ICF 20-6 52 ICF (25-40)-4 ICF (25-40)-6 Connection type Weight* [kg] [lbs] 20 D (3/4 ) 25 D (1 ) 32 D (1¼ ) 20 A (3/4 ) 20 SOC (3/4 ) 25 SOC (1 ) 32 SOC (1¼ ) 3.6 7.7 754 20 D (3/4 ) 25 D (1 ) 32 D (1¼ ) 20 A (3/4 ) 20 SOC (3/4 ) 25 SOC (1 ) 32 SOC (1¼ ) 5.3 11.7 52 754 25 D (1 ) 32 D (1¼ ) 40 D (1½ ) 32 A (1¼ ) 25 SOC (1 ) 32 SOC (1¼ ) 40 SOC (1½ ) 8.2 18.1 52 754 25 D (1 ) 32 D (1¼ ) 40 D (1½ ) 32 A (1¼ ) 25 SOC (1 ) 32 SOC (1¼ ) 40 SOC (1½ ) 12.6 27.8 * Without modules 6 DKRCI.PA.FT0.A1.22 / 520H5093 Produced by Metaphor, 01-2011

Application Guide The following module configurations are possible: Function Module Type Can be installed in these locations ICFS Stop valve module M2 ICFR Manual regulating valve module M2 ICFF Filter (strainer) module M2 ICFE Solenoid valve module ICFC Check valve module ICFN Stop/check valve module ICM Motor valve module ICFB Blank top cover M2 ICFA Electronic expansion valve module (for ICF 20 only) ICFE20H Solenoid valve module (for ICF 20 only) ICFO Manual opening module ICFW Welding module (for ICF 25-40 only) M2 Module locations are indicated by, M2,,, M5 and M6. With respect to refrigerant flow, is closest to inlet. All ICF (20-40)-6 DIN and ANSI connections with 4 side ports All ICF (20-40)-6 SOC connections with 6 side ports Example: ICF 20-6-5A DIN Example: ICF 20-6-2H SOC All ICF (20-40)-4 DIN and ANSI connections with 2 side ports All ICF (20-40)-4 SOC connections with 4 side ports Example: ICF 25-4-9 DIN Example: ICF 25-4-9 SOC Produced by Metaphor, 01-2011 DKRCI.PA.FT0.A1.22 / 520H5093 M5 M5 M6 M6 M6 M6 M6 M5 M5 M5 M5 M5 M6 M6 7

Application Guide Design work with ICF When designing with ICF, Danfoss provides engineering tools that simplifies the design phase. CoolSelector Sizing through CoolSelector provides fast and accurate selection while obtaining performance information based on operating conditions. All standard configuration are available in the software. However, custom configurations of the ICF is possible. Contact you local representative for availability. CAD symbols 2D & 3D When designing new units and applications, CAD drawings are essential for getting the job done as precisely and easily as possible. Danfoss provides low file-size CAD symbols for all standard ICF code. These CAD symbols make it easy for all design engineers to make quick and compact designs. Visit www.danfoss.com to explore more about the product and CAD symbols. 8 DKRCI.PA.FT0.A1.22 / 520H5093 Produced by Metaphor, 01-2011

Application Guide Standard applications ICF is recommended for use in the following standard applications: Pumped liquid line. Hot gas defrost. Liquid injection to separator (Liquid make up). Compressor liquid injection. Low temperature evaporator To liquid separator From discharge line PMLX/GPLX CVP ICF 20-4-9 ICS From liquid separator ICF 20-6-2 Liquid injection (Liquid make up) EKC 347 AKS 41 From receiver Liquid separator ICF 20-6-5A Produced by Metaphor, 01-2011 DKRCI.PA.FT0.A1.22 / 520H5093 9

Application Guide Pumped liquid line The ICF 20-6-2 and ICF (25-40)-6-3 are designed for a typical pumped liquid line in a flooded evaporator system. The ICF valve station consists of the following modules: ICF20-6-2 ICF(25-40)-6-3 ICFS (Stop valve) ICFS (Stop valve) M2 ICFF (Filter) ICFF (Filter) ICFE (Solenoid valve) ICFE (Solenoid valve) ICFO (Manual opener for ICFE) ICFC (Check valve) M5 ICFR (Regulation valve) ICFR (Regulation valve) M6 ICFN (Stop/Check valve) ICFS (Stop valve) ICF 20-6-2 For loads exceeding, the ICF 20-6-2 is available with a high capacity solenoid valve, the ICFE 20H. With this configuration the ICF is called ICF 20-6-2H. For loads exceeding the suitable level for the ICF 20-6-2H please use the ICF (25-40)-6-3. Capacities Maximum recommend capacities according to following conditions Refrigerant: NH 3, R717 T e : -30 C / -20 F Circulation rate: 3:1 Model: Capacity* [KW] Capacity* [TR] Connection[DN] Connection [ANSI] ICF 20-6-2 90 25 20 ¾ ICF 20-6-2 125 35 25 1" ICF 20-6-2H 140 40 25 1" ICF 20-6-2H 140 40 32 1 ¼ ICF 25-6-3A 210 60 25 1" ICF 32-6-3B 265 75 32 1 ¼ ICF 40-6-3B 350 100 40 1 ½ Maximum recommendable capacity. Pipe velocity (1 m/s / 3.28 ft/s)) used as dimensioning factor together with the pressure drop across the solenoid valve. Capacity based on approximate pressure drop of 0.2 barg / 4 psig. Capacity variations are minimal at other evaporating temperatures. Ordering ICF 20-6 ICF20-6-2 ICF20-6-2H Connection Side ports [*] Code Code 20D ( 3 / 4 in.) 4 027L3009 25D (1 in.) 4 027L3011 027L3309 32D (1¼ in.) 4 027L3012 027L3310 20A ( 3 / 4 in.) 4 027L3013 20 SOC ( 3 / 4 in.) 1 ) 6 027L3014 25 SOC (1 in.) 1 ) 7 027L3016 027L3312 32 SOC (1¼ in.) 1 ) 7 027L3017 027L3313 ICF (25-40)-6 ICF25-6-3A ICF32-6-3B ICF40-6-3B Connection Side ports [*] Code Code Code 25 D (1 in.) 4 027L4020 25 SOC (1 in.) 1 ) 7 027L4021 32D (1¼ in.) 4 027L4029 32 SOC (1¼ in.) 1 ) 7 027L4031 40 D (1½ in.) 4 027L4034 40 SOC (1½ in.) 1 ) 7 027L4035 * Four side ports include four blind plugs and one ½ in. connector. Side ports in P2/P7 and P5/P10. Side ports are 3 / 8 G for butt weld connection or 3 / 8 NPT for socket weld connection. 1 ) Especially for the North American market 10 DKRCI.PA.FT0.A1.22 / 520H5093 Produced by Metaphor, 01-2011

Application Guide Hot gas defrost The ICF 20-4-9 and ICF (25-40)-4-9 are designed to provide the necessary functions for hot gas defrost on evaporators. The ICF consist of the following modules: ICF20-4-9 ICF(25-40)-4-9 ICFS (Stop valve) ICFS (Stop valve) M2 ICFF (Filter) ICFF (Filter) ICFE (Solenoid valve) ICFE (Solenoid valve) ICFS (Stop valve) ICFS (Stop valve) ICF 20-4-9 For loads exceeding, the ICF 20-4-9 is available with a high capacity solenoid valve, the ICFE 20H. With this configuration the ICF is called "ICF 20-4-9H". For loads exceeding the suitable level for the ICF 20-4-9H, please use the ICF (25-40)-4-9. Capacities Maximum recommend capacities according to following conditions: Refrigerant: NH 3, R717 T e : -30 C / -20 F T c : 30 C / 86 F Subcooling: 0 C / 0 F Superheat: 0 C / 0 F Model: Capacity* [KW] Capacity* [TR] Connection[DN] Connection [ANSI] ICF 20-4-9 35 10 25 1" ICF 20-4-9 45 13 32 1 ¼ ICF 20-4-9H 50 14 25 1" ICF 20-4-9H 65 18.5 32 1 ¼ ICF 25-4-9 105 30 25 1" ICF 32-4-9 140 40 32 1 ¼ ICF 40-4-9 210 60 40 1 ½ * Maximum recommendable capacity. Pipe velocity (15 m/s) used as dimensioning factor together with the pressure drop across the solenoid valve. ** If needed the ICF 20-4 and ICF(25-40)-4 can be delivered with a regulation valve (HEV) in instead of the stop valve, by using the standard configuration ICF 20-4-10 or ICF(25-40)-4-10 Ordering ICF 20-4 ICF20-4-9 ICF20-4-9H Connection Side ports [*] Code Code 25D (1 in.) 2 027L3067 027L3333 32D (1¼ in.) 2 027L3068 027L3334 20A ( 3 / 4 in.) 2 027L3069 25 SOC (1 in.) 1 ) 4 027L3336 32 SOC (1¼ in.) 1 ) 4 027L3337 ICF (25-40)-4 ICF25-4-9 ICF32-4-9 ICF40-4-9 Connection Side ports [*] Code Code Code 25 D (1 in.) 2 027L4063 25 SOC (1 in.) 1 ) 4 027L4064 32 D (1¼ in.) 2 027L4067 32 SOC (1¼ in.) 1 ) 4 027L4069 40 D (1½ in.) 2 027L4072 40 SOC (1½ in.) 1 ) 4 027L4073 * Four side ports include four blind plugs and one ½ in. connector. Side ports in P2/P7 and P5/P10. Side ports are 3 / 8 G for butt weld connection or 3 / 8 NPT for socket weld connection. 1 ) Especially for the North American market Produced by Metaphor, 01-2011 DKRCI.PA.FT0.A1.22 / 520H5093 11

Application Guide Liquid injection to separator (Liquid make up) The ICF valve station offers a unique solution for liquid injection to separator. For this application the ICF (20-40)-6-5 is recommended. Using the ICF (20-40)-6-5 the valve provides you with an advanced ICM motor control valve with a solenoid in front. It is delivered with a sight glass in the side port of the valve housing. For fail safe operation this type of ICF is equipped with a ICFE solenoid valve in front of the ICM motor operated valve. The ICF consist of the following modules: ICF20-6-5 ICF(25-40)-6-5 ICFS (Stop valve) ICFS (Stop valve) M2 ICFF (Filter) ICFF (Filter) ICFE (Solenoid valve) ICFE (Solenoid valve) ICFO (Man. opener for ICFE) ICFB (Blank top cover) M5 ICM (Elect. motor valve) ICM (Elect. motor valve) M6 ICFS (Stop valve) ICFS (Stop valve) ICF 20-6-5 The ICF 20-6-5 is available in versions A, B and C, referring to the capacity of the electronic motor valve. ICF (25-40)-6-5 is available in version A. Capacities Maximum recommend capacities according to following conditions: Refrigerant: NH 3, R717 T e : -20 C / -4 F T c : 30 C / 86 F Subcooling: 5 C / 9 F Superheat: 0 C / 0 F Model: Capacity* [KW] Capacity* [TR] Connection[DN] Connection [ANSI] ICF 20-6-5A 175 50 20 ¾" ICF 20-6-5AH 210 60 25 1" ICF 20-6-5BH 500 142 25 1" ICF 20-6-5CH 670 190 32 1 ¼" ICF 25-6-5A 670 190 25 1" ICF 32-6-5A 1140 320 32 1 ¼ * Maximum recommendable capacity. Pipe velocity (1 m/s) used as dimensioning factor together with the pressure drop across the solenoid valve. Note: For larger capacities use larger individual weld-in components such as SVA, FIA,ICS,ICM,SVA. Ordering ICF 20-6 ICF20-6-5A ICF20-6-5AH ICF20-6-5B ICF20-6-5BH ICF20-6-5C ICF20-6-5CH Connection Side ports [*] Code 20D ( 3 / 4 in.) 4 027L3034 Code Code Code Code Code 25D (1 in.) 4 027L3036 027L3322 027L3042 027L3325 027L3047 027L3328 32D (1¼ in.) 4 027L3048 027L3329 20A ( 3 / 4 in.) 4 027L3037 027L3043 20 SOC ( 3 / 4 in.) 1 ) 6 027L3038 027L3127 25 SOC (1 in.) 1 ) 6 027L3040 027L3323 027L3045 027L3326 027L3051 027L3330 32 SOC (1¼ in.) 1 ) 6 027L3052 027L3331 ICF (25-40)-6 ICF25-6-5A ICF32-6-5A ICF 40-6-5A Connection Side ports [*] Code 25 D (1 in.) 4 027L4038 25 SOC (1 in.) 1 ) 6 027L4039 Code Code 32 D (1 in.) 4 027L4042 027L4042 32 SOC (1¼ in.) 1 ) 6 027L4044 027L4044 40 D (1½ in.) 4 027L4148 * Four side ports include four blind plugs and one ½ in. connector. Side ports in P2/P7 and P5/P10. Six side ports include six blind plugs. Side ports in P2/P7, P4/P9 and P5/P10. Side ports are 3 / 8 G for butt weld connection or 3 / 8 NPT for socket weld connection. 1 ) Especially for the North American market 12 DKRCI.PA.FT0.A1.22 / 520H5093 Produced by Metaphor, 01-2011

Application Guide Accessories for ICF 20-40 u w y v x u ICAD actuator ICAD 600 With 1,5m cable 027H9065 v Stop needle valves SNV-ST G½ (Qty. 1) 148B3778 ICAD 600 Without cables 027H9100 SNV-ST 3 / 8 " NPT-FPT Other SNV types see literature: DKRCI.PD.KB0.A 148B4181 Cable Cable set 10 m. 027H0427 Cable Cable set 15 m. 027H0435 Connector Connector set female 027H0430 Protection cap Protection cap for ICAD 027H0431 ICAD details see literature: DKRCI.PD.HT0.A w Coils Coils 10 W 21 VA with terminal box IP 67 220-230 V 50 Hz 018F6701 115 V 60 Hz 018F6813 Other coil types see literature: DKRCI.PD.FT0.A x Sight glass and connector Sight glass G 3 / 8 (Qty. 2) 027L1267 (for DIN and ANSI connections only) v Pressure transmitters AKS 33 G 3 / 8 (Qty. 1) LP -1 to 12 bar (-30 to 40 C) 060G2105 Sight glass NPT 3 / 8 (Qty. 2) 027L1268 (for SOC connection only) AKS 33 G 3 / 8 (Qty. 1) HP 0 to 25 bar (0 to 80 C) 060G2115 Connector G 3 / 8 G½ (Qty. 2) 027L1266 (for DIN and ANSI connections only) AKS 33 1 / 4 " NPT (Qty. 1) 0-100 psia (-40-185 F) 060G3802 Additional spare parts see literature: DKRCI.PY.FT0.A AKS 33 1 / 4 " NPT (Qty. 1) 0-200 psia (-40-185 F) 060G1711 y Gaskets for ICF Complete set of gaskets ICF20 Complete set of gaskets ICF25-40 027L1261 027L2260 Other AKS 33 types see literature: RD5GH Produced by Metaphor, 01-2011 DKRCI.PA.FT0.A1.22 / 520H5093 13

Produced by Metaphor, 01-2011

Produced by Metaphor, 01-2011

MAKING MODERN LIVING POSSIBLE Danfoss Industrial Refrigeration Your One-Stop-Shop We have more than 60 years of experience producing valves and controllers for Industrial Refrigeration and we focus on our core business of making quality products that enhance performance and reduce total life cycle costs the key to major savings. Some of the products from our very extensive product range: ICF Control Solution ICV Control Valves Liquid Level Controls Line Components Stop and Regulating Valves Safety Relief Valves For further information; please visit our web site www.danfoss.com/ir We also offer a wide range of products for CO 2. All our products are designed and tested to ensure that they can withstand the impact of CO 2 in all aspects. Please visit www.danfoss.com/co2 16 DKRCI.PA.FT0.A1.22 / 520H5093 Produced by Metaphor, 01-2011