arxiv: v1 [physics.ins-det] 16 Aug 2014

Similar documents
arxiv: v1 [physics.ins-det] 6 May 2016

ATLAS RPC QA results at INFN Lecce

Assembly and Testing of RPCs in Pakistan. Hafeez Hoorani National Centre for Physics

Analysis of RPC Performance with Different Gas Mixture

arxiv: v1 [hep-ex] 18 Sep 2012

Preliminary results of Resistive Plate Chambers operated with eco-friendly gas mixtures for application in the CMS experiment

arxiv: v1 [physics.ins-det] 4 May 2016

The Resistive Plate Chamber detectors at the Large Hadron Collider experiments. Danube School, September 8-13, 2014 Novi Sad

Long term stability tests of INO RPC prototypes

PHENIX RPC in China. Xiaomei LI. Science and Technology on Nuclear Data Laboratory China Institute of Atomic Energy

PERFORMANCE OF THE GAS GAIN MONITORING

RPC CHARACTERIZATION AND TESTING ( by S. Mathimalar, INO Student)

ARTICLE IN PRESS. Nuclear Instruments and Methods in Physics Research A

Guideline for RMO Key comparison for Air kerma rate in 60 Co gamma radiation

GAS ANALYSIS AND MONITORING SYSTEMS

Study of Mixed Gas Flow Pattern Inside RPC

ARTICLE IN PRESS. Nuclear Instruments and Methods in Physics Research A

Badan Jadrowych Nuclear Research Institute. Report INR No. 739/XIX/D CERN LIBRARIES, GENEVA CM-P Differential Recombination Chamber

EUROPEAN LABORATORY FOR PARTICLE PHYSICS STUDY OF AGEING AND GAIN LIMITS OF MICROSTRIP GAS CHAMBERS AT HIGH RATES

RADIATION PROCEDURES MANUAL Procedure Cover Sheet

The Discussion of this exercise covers the following points:

Development of small, easy to build and low gas consumming timing RPCs

The SPI Sputter Coater Handbook

Design and Construction of a GEM-TPC Prototype for R&D Purposes

BaBar Forward Endcap Upgrade

Additives that prevent or reverse cathode aging in drift chambers with Helium-Isobutane gas *

ETCHING OF COPPER COATED MYLAR TUBES WITH CF4 GAS. Karl M. Ecklund, Keith W. Hartman, Michael J. Hebert, Stanley G. Wojcicki

A Journal of Practical and Useful Vacuum Technology. By Phil Danielson

Designing Wave Energy Converting Device. Jaimie Minseo Lee. The Academy of Science and Technology The Woodlands College Park High School, Texas

Assembly and measurements of a mechanical prototype of the BIS MDT chamber

CHAPTER 4 PRE TREATMENT PATIENT SPECIFIC QUALITY ASSURANCE OF RAPIDARC PLANS

LINEAR TRANSFORMATION APPLIED TO THE CALIBRATION OF ANALYTES IN VARIOUS MATRICES USING A TOTAL HYDROCARBON (THC) ANALYZER

KATEDRA MATERIÁLOVÉHO INŽENÝRSTVÍ A CHEMIE. 123MEAN water vapor transport

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment Varian 310

Wind Regimes 1. 1 Wind Regimes

Relative Dosimetry. Photons

Performance of a triple-gem detector for high rate charged particle triggering

This educational seminar discusses creating, measuring, and troubleshooting Rough Vacuum.

EFFECTS OF OUTGASSING FROM SOME MATERIALS ON GAS CHAMBER AGEING

SPIRIT III Radiometer Saturation Effect

PENETRATION OF N95 FILTERING- FACEPIECE RESPIRATORS BY CHARGED AND CHARGE- NEUTRALIZED NANOPARTICLES

EcoCell Vertical Electrophoresis Unit

Exercise 5-2. Bubblers EXERCISE OBJECTIVE DISCUSSION OUTLINE. Bubblers DISCUSSION. Learn to measure the level in a vessel using a bubbler.

Barrier Development and Evaluation Methodology. D.S. Musgrave 1 1 Thermal Visions, Inc., Granville, USA

THE development of more advanced techniques in radiotherapy,

Development of high pressure-high vacuum-high conductance piston valve for gas-filled radiation detectors

TG-61 deals with: This part of the refresher course: Phantoms. Chambers. Practical Implementation of TG-61:

BEST KNOWN METHODS. Transpector XPR3 Gas Analysis System. 1 of 6 DESCRIPTION XPR3 APPLICATIONS PHYSICAL INSTALLATION

Guidance on room integrity testing and its interpretation

Characteristics and Production of Gas Sealed, Radiation Hard, Small Ionization Chambers

Max Planck Institute, Munich. January 10, Because of the concern about long-term silicon contamination of MDTs, we

Old-Exam.Questions-Ch-14 T072 T071

Acoustic Emission Testing of The Shell 0f Electromagnetic Valve

Gas Leak Measurement of TRT Barrel Module

Monitoring Gas Pressure in Vacuum Insulation Panels

Diaphragm pop-pop engine

Laser-Induced Bubbles in Glycerol-Water Mixtures

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

The use of remote plasma emission spectroscopy as an alternative method of gas sensing for direct monitoring of vacuum processes

Inert Atmosphere Guide

The Discussion of this exercise covers the following points:

Technical protocol of APMP key comparison for measurement of air kerma for 60 Co (APMP.RI(I)-K1.1)

FIG: 27.1 Tool String

LABORATORY EXERCISE 1 CONTROL VALVE CHARACTERISTICS

Gas system Upgrade for the BaBar IFR detector at SLAC

Gas Pressure Regulator HON 300

Sailboat Mast charging due to Corona current in an Electric Field

Analyses of the fuel cell stack assembly pressure

Influence of rounding corners on unsteady flow and heat transfer around a square cylinder

Exercise 2-2. Second-Order Interacting Processes EXERCISE OBJECTIVE DISCUSSION OUTLINE. The actual setup DISCUSSION

ELEVATION CORRECTION FACTORS FOR RADON MONITORS*

UK Opportunities in SiD Calorimetry

1)! DO NOT PROCEED BEYOND THIS MARK

Electrochemical Sensor

Clinical Implementation of the TG-51 Protocol. David Followill Radiological Physics Center Houston Texas

LOW PRESSURE EFFUSION OF GASES revised by Igor Bolotin 03/05/12

Analysis of Pressure Rise During Internal Arc Faults in Switchgear

Only 8% to go. TOTAL 1494 of 1623 ACTIVE INSTITUTIONS (92%) May-09. May-04 Nov-04. May-07. Nov-02 May-03. Nov-05. Nov-06. Nov-07 May-08.

THE COLLEGE OF AERONAUTICS CRANFIELD

CORESTA RECOMMENDED METHOD N 6

IGUMA - IGU Design Limitations

Operating Procedures for Metal Evaporator I

Effect of Inlet Clearance Gap on the Performance of an Industrial Centrifugal Blower with Parallel Wall Volute

Commissioning an IMRT System for MLC Delivery. Gary A. Ezzell., Ph.D. Mayo Clinic Scottsdale

Gun Vacuum Performance Measurements February 2003

Load Responsive Multilayer Insulation Performance Testing

WP2 Fire test for toxicity of fire effluents

TECHNICAL DATA. Q = C v P S

CNS In-Pool Assembly Mechanical Design for OYSTER Project

Introductory Lab: Vacuum Methods

CFD AND EXPERIMENTAL STUDY OF AERODYNAMIC DEGRADATION OF ICED AIRFOILS

Certification of AMS acc. EN 15267, Part 3 - Overview and First Experience -

Leak Checking Large Vacuum Chambers

Denise L Seman City of Youngstown

Effect of Fluid Density and Temperature on Discharge Coefficient of Ogee Spillways Using Physical Models

Impact of imperfect sealing on the flow measurement of natural gas by orifice plates

Micro Channel Recuperator for a Reverse Brayton Cycle Cryocooler

Yoke Instrumentation: ILD Muon System / Tail Catcher. Valeri Saveliev IAM, RAS, Russia DESY, Germany 3 June, 2016

Installation, use and maintenance instructions. Gas burner (5)

On the possibilities for the readout of gas scintillation detectors for neutron scattering applications

Transcription:

Preprint typeset in JINST style - HYPER VERSION RPC Gap Production and Performance for CMS RE4 Upgrade arxiv:1408.3720v1 [physics.ins-det] 16 Aug 2014 Sung Keun Park, Min Ho Kang and Kyong Sei Lee Korea Detector Laboratory, Department of Physics, Korea University, Seoul, 136-713, Korea E-mail: sungpark@korea.ac.kr ABSTRACT: CMS experiment constructed the fourth Resistive Plate Chamber (RPC) trigger station composed of 144 RPCs to enhance the high momentum muon trigger efficiency at both endcap regions. All new CMS endcap RPC gaps are produced in accordance with QA and QC at the Korea Detector Laboratory (KODEL) in Korea. All qualified gaps have been delivered to three assembly sites: CERN in Switzerland, BARC in India, and Ghent University in Belgium for the RPC detector assembly. In this paper, we present the detailed procedures used in the production of RPC gaps adopted for the CMS upgrade. KEYWORDS: Gaseous Detector; Resistive Plate Chambers; Muon Trigger. Corresponding author.

Contents 1. Introduction 1 2. Gap Production 1 2.1 Gas Volume Production 2 2.2 Linseed Oil Treatment 4 2.3 Dark Current Measurement 4 3. Resistivity of RPC Gap Measurement 5 4. Conclusions 6 1. Introduction In the current project, a total of 144 RE4 Resistive Plate Chambers (RPCs) are manufactured, tested, and are being installed at the fourth endcap RPC station in the CMS detector. One unit of the standard CMS endcap RPCs consists of 3 gaps forming double layers. It means that 432 gas gaps should be produced for the assembly of 144 RE4 RPC modules. An additional 200 gaps are produced for the contingency and future repairs of any damaged RPC modules. The RE4 RPCs are required to be mounted in two concentric rings RE4/2 and RE4/3 with 36 RPCs per ring. The shapes of the gaps are trapezoidal. The heights of the RE4/2 and RE4/3 gaps are 1663 and 1930 mm, respectively [1]. The Korea Detector Laboratory (KODEL) produces the endcap RPC gaps for CMS. KODEL utilizes the dedicated RPC mass production facilities for gaps in which the entire CMS endcap RPC gaps have been produced since 1997. The RPC gaps have been delivered to three RPC assembly sites; CERN in Switzerland, BARC in India, and Ghent University in Belgium for the detector assembly. 2. Gap Production Mass production of the RPC gaps relies on several major facilities at KODEL: the graphite coating facility, the PET film coating facility, the spacer bonding and gas leak test facility, the linseed oil treatment facility, and high voltage (H.V.) test facility where dark currents are monitored and measured. Quality Control (QC) is imbedded in the process of RPC gap production. Because QC can be defined as a collection of protocols to select the product that meets the technical specifications, all of the produced gaps are subject to QC. 1

Figure 1. Graphite coating facility (left column) and PET film coating facility (right column). QC is further divided into the components of the RPCs. The main item for QC-1 is High Pressure Laminate (HPL) panels, the Bakelite. QC-2 is for gaps while QC-3 is for chamber assembly and operation. QC-3-1 concerns chamber assembly and QC-3-2 concerns performance assessment of the detector with cosmic ray muons. QC-4 is for chambers and super modules. QC in this paper will be focused on the QC-2 designed for the gap production. 2.1 Gas Volume Production Figure 2. Gap bonding facility (left column) and linseed oil treatment facility (right column). The electrodes of the RPC gaps are produced at KODEL with a thin layer of graphite. The surface resistivity of the electrode is checked as the first step of the QC-2. The surface resistivity 2

should range from 100 to 250 kω/square [2]. The next step of the QC-2 is to check the mechanical stability of the gap once it is produced. To secure the uniform electric field within the gap, homogeneous 2 mm separation is achieved by the spacers. The secure bonding of the spacers on the surface of the electrode made of Bakelite is checked. The pressure variation of the gaps when the spacer is pressed by a KODEL robot is an effective indicator of the good bonding, as Fig. 3 shows. Another property of the RPC gap to check in QC-2 is the gas leakage rate. This leakage rate measurement is performed within the frame work of the bonding test. Figure 3. KODEL robot performing the pressure test. The dimensions of the table are 175 cm x 250 cm (left). The control console of the pressure test (right). Fig. 4 shows the results of QC-2 registering the pressure variation when pressed on the spacers. Differences at the beginning and end of the pressure measurement include the gas leak rate of the gas gaps. The curve usually shows a gradual decreases in pressure if the gap has a small leakage rate. If a gap without loosen spacers has the gradual slope of the gas leak within the acceptable range, the gap is prepared to move to a linseed-oil procedure. The allowed maximum leakage rates for 10 minutes are 0.2, 0.3 and 0.4 hpa for RE4-2 Top Wide (TW), Top Narrow (TN) and Bottom gaps, respectively. For RE4-3 gaps 0.3, 0.4, 0.5 hpa for TW, TN and Bottom gaps, respectively. Figure 4. Outcome of the pressure test. Pressure variation of the gap for all secured spacers (left) and loosen spacers (right). 3

2.2 Linseed Oil Treatment During the linseed oil treatment process, the entire gas volume is filled with linseed oil. Once dried with air, the oiled surface forms the polymerized layer. It shows that the polymerized layer on the surface of the bakelite inside the gas volume reduces the spurious noise by a factor of 10 in the avalanche operation mode [3]. This procedure needs a cautious preparation due to the pressure built up by the linseed oil filling the gas gap. The pressure within the gap should remain less than 20 hpa over the atmospheric pressure to ensure that the gas gap is not over-pressured to the limit of its epoxy bonding strength. 2.3 Dark Current Measurement Figure 5. Dark currents of gaps as a function of H.V. up to 10 kv before (blue) and after 120-hour long test (red). The dark current measurement has three steps. The first part is a H.V. scanning up to 10 kv. Dark current is measured as H.V. increases up to 10 kv as shown in Fig. 5. In this step, the amount of current drawn from gaps at 6 kv should not exceed 1.5 µa. At 10 kv, the maximum 5 µa is allowed for smaller gaps and the maximum 10 µa for larger gaps. Each plot has two components: one linear component rising from zero up to 7 kv and another with an exponential rise from 8 kv up to 10 kv. It is the characteristic curve in the HV scanning. Dark current at 6 kv is important; at this point the current is not originated from the avalanche of the gas ionization yet. Up to 7 kv the current is mainly the ohmic current flowing through the surface of the gaps. Above 8 kv the avalanche of the gas ionization contributes to the exponential rise of the currents. A 120-hour long monitoring of gap currents at 9.6 kv is shown in Fig. 6. It shows the characteristic gradual decrease of the current during the initial 40 hours, and thereafter, it slightly increases. Finally, the H.V. scanning up to 10 kv is performed one more time. Two different mea- 4

Figure 6. Dark currents of gaps at 9.6 kv as a function of time up to 120 hours. surements of the dark currents before and after the 120-hour long measurement are plotted against each other to detect any significant variations in Fig. 5. 3. Resistivity of RPC Gap Measurement Figure 7. Resistivities of six small gaps (left) measured by gamma irradiations using 137 Cs source (right). During QC-1 visual inspection, any damaged HPL panels were kept separately not to be used in the gap production. Out of some damaged HPL panels delivered to KODEL in May 2013, we produced six small RPC gaps. The effective area of each gap was 30 30 cm 2. We measured the resistivity of the RPC gaps by irradiating the six RPC gaps with 136-mCi 137 Cs source. The distance from gaps to the source was between 26 and 35 cm as depicted in Fig. 7. The gas composition used in this test was Freon 95% + Iosbutane 5% with water vapor added with a mass ratio of 1%. As an independent measurement, we also used pure argon gas with water vapor added with a 5

mass ratio of 1%. Currents drawn from six small gaps during the measurement with pure argon as a function of H.V. are plotted in Fig. 8 The measured resistivities ρ, from both methods were normalized to the value at 20 C. ρ 20 b = ρ T e α(t T 0), where the temperature coefficient α=0.13 C 1. From the 137 Cs source irradiation we obtained the mean value of the resistivity of the six RPC gaps ρ=1.42±0.07 10 11 Ωcm. The resistivity measured using pure argon gas yielded the mean value of ρ=3.03 ± 0.23 10 11 Ωcm. The resistivity measured using pure argon gas was 2.13 times higher than the result obtained by the gamma irradiation method. Therefore, we drew an empirical conversion factor, C, to convert the resistivity from argon to the gamma irradiation C = 0.47. We then measured the resistivity of 23 TW RE4-2 gaps using the argon method. The yielded mean resistivity of the 23 TW gaps was ρ=1.35 10 11 Ωcm. Applying the conversion factor obtained from the comparison of the irradiation with pure argon methods, we estimated the resistivity of the 23 TW4-2 gaps ρ to be 6.33 10 10 Ωcm. This exercise was to check the expected variation of the resistivity of the HPL panels over periods when stored without special climate control. From this frame of estimation, we found that the resistivity of the gaps was within the expected values. Figure 8. Currents of the six small gaps as a function of H.V. with pure argon. 4. Conclusions KODEL produced 686 RPC gaps in 22 months. The rate at which the qualified gaps are produced is 96%. These statistics show that the QC adopted in RPC gap production has been effective for the mass production of RPC gaps. The resistivities of the RPC gaps were measured with two different methods; pure argon gas method and gamma irradiation method. We found that these two methods were comparable and the average resistivity of the gaps was within the expected values. Acknowledgments We acknowledge the support of Korea University and the Korean Research Foundation. 6

References [1] CMS Collaboration, The Muon Project, Technical Design Report, CERN/LHCC 97-32, December 1997 [2] S. Park et al., Production of gas gap for Forward RPCs of the CMS experiments, Nucl. Instr. Meth. A 550 (2005) 551 [3] S. Park et al., Beam test results of CMS RPCs at high eta region under high-radiation environment, Nucl. Instr. Meth. A 533 (2004) 37 7