Industrial cable glands

Similar documents
HSK-EMV-Industry Standard

CABLE GLANDS. Connector~Tech Providing Harsh Environment Connector SOLUTIONS

Cable entries. Contents. Cable entries. Cable entries Introduction L.2 L.1. Standard cable glands - Plastic L.5. Standard cable glands - Brass L.

Cable entries. Contents. Cable entries. Cable entries Introduction C.2 C.1. Standard cable glands - Plastic C.6. Standard cable glands - Brass C.

Cable Glands. Special Applications. RoHS Compliance. Plastic & Metal Cable Glands Adapters Reducers & Enlargers Grommets & Accessories

SEALED CONNECTORS FOR THE LIMIT SWITCHES

E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10. Cable gland Series 8161/7, 8161/8. Installation Equipment and Accessories E10/1.

IP 69 Protection against water under pressure

Pressure Measurement Single-range transmitters for general applications

Underwater Fiber-Optic Plane Irradiance Collector

Assembly instruction. Operating temperature range -60 C +85 C Protection. IP 66, 67, 68 (5 bar)

Masthead Sensor Installation Guide

February Cable glands For general industry and hazardous areas

Liquid Tight Strain Relief Fittings, Accessories & Conduit System

FITTINGS THREAD LUBRICANTS. Fittings 20,000 PSI

Plok. Rapid Mating Multi-Pin Industrial Connector. Amphenol Industrial Sine Systems * Pyle Connectors Corporation

Installation Instructions

enclosures to ATEX and enclosures for special custom design (EEx p and NEMA cabinets)

Magnetic level switch type MR783 Instruction Manual

INTERLOCKED METAL HOSE

Hoses and Lances 20,000 PSI

Installation Manual , Rev BB December Micro Motion H-Series Hygienic Coriolis Flow and Density Sensors

SKINTOP. Cable glands

enclosures to ATEX and enclosures for special custom design (EEx p and NEMA cabinets)

High-performance submersible pressure transmitter For level measurement Model LH-10

AMTEC SUPPORT GRIPS STANDARD, HEAVY DUTY & CONDUIT GRIPS

sitrans p Operating Instructions (de/en) Edition 03/2004

REMKE STYLE PowR-TECK CONNECTORS

JUMO dtrans p30 Pressure Transmitter

Operating Instructions

Operating Instructions

Installation Manual , Rev BC January Micro Motion R-Series Coriolis Flow Sensors

with self-sealing gas valve system

Installation Instructions for Tavan Models TAV-XX-XX

PKP Prozessmesstechnik GmbH. Borsigstrasse 24. D Wiesbaden-Nordenstadt. Tel: / Fax: / Operating Instructions

FLAMMABLE GAS SENSOR/TRANSMITTER

UNITY 2. Uni-DAAMS Manual. Version 1.3 (Changes to Section 1.1) March 2010

UNIK 5600/5700 Marine Certified Pressure Sensing Platform

FIELD DEVICES ANALYTICAL Product Specifications

Installation Instructions MODEL VSTI-A020 Tank Indicator Installation Model: VSTI-A020, Stainless Reverse Read System Versa Steel Inc. Guide Cables No

Armatures for analytical probes

Installing a Probe. Typical Installation

Liquid Tight Strain Relief Fittings, Accessories & Conduit System. Our Servicei makes the difference! ULf1 746C. Committed To Excellence!

SITRANS P measuring instruments for pressure

Junction Boxes Series 8118

9408 series Dissolved oxygen systems

Single and Triple Rain Barrel Setup

Shimano Di2 Installation on S5

Pressure switch and Thermostat CAS

COOPER POWER SERIES. 200 A 15/25 kv class deadbreak straight connector installation instructions. Deadbreak Apparatus Connectors MN650043EN

P900. P900, Datenblatt Seite 1 DESCRIPTION

Ventilation Plugs (Pressure Balance Elements)

High-performance submersible pressure transmitter For level measurement Model LH-10

AP100 series ph/redox (ORP) cartridge sensors with water-wash option

PN LINE. Technical remarks PN 11 PN 13 PN 14 PN 15 PN 17 PN 18 PN 20 PN 23 PN 25 PN 26 PN 27 PN 28 PN 29 PN 37 PN 38 PN 39 PN 40 PN 43 PN 10 8_9 10_12

UNIK 5600/5700. Marine Certified Pressure Sensing Platform. High Quality. Features. Bespoke as Standard. Expertise. bhge.com

GILMONT ACCUCAL FLOWMETERS

High Pressure Heatable Liquid Cells GS05910, GS05915, GS05920, GS05925 Series User Manual

OPTIBAR P 1010 C Technical Datasheet

INSTRUCTION MANUAL. January 23, 2003, Revision 0

Level transmitter LT 100

Pegasus Series Amphenol Pcd

Hydrostatic Level Measurement waterpilot FMX 160

Pro-Tekt European Cable System. Technical Catalog

SILVYN Conduit, Sleeving & Cable Carrier Systems

Technical Bulletin. Parts and Service News. LPG Lock-Off valve replacement procedures for 4.2 Liter Ford V6

COOPER POWER SERIES. 200 A 15/25 kv class elbow installation instructions. Deadbreak Apparatus Connectors MN650042EN

PERSONAL FALL PROTECTION

Media-Isolated Mag Plus Probe Low Pressure-ISO Kit

K&B Vault and Riser Closures

DMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0.

SECTION 2 RING MOUNT

CONUS MSR0680 UNDERWATER LIGHT. Registered Community Design. Operating Instructions

Features. Up to 6 switch points Minimum degree of protection IP65 Optional temperature sensor PT1000 or thermostat Potted electrical contacts

C-Flow Coriolis Mass Flow Meters

Pressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview

PLIO Mouldings in flexible PVC

PLAQUE MFM18240 UNDERWATER LIGHT. Operating Instructions

Stirred Reactors and Pressure Vessels

PROPORTIONING VALVE. Model 150 INSTRUCTION MANUAL. March 2017 IMS Company Stafford Road

Hydro Bond Engineering Ltd Electrical Penetrators: Manned and Unmanned Systems HPS (Hydro Bond Penetrator Series)

Hydrostatic. Continuous level measurement. Overview Page 188 VEGAWELL 52 Page 190 VEGABAR 86, 87 Page 192 Accessory Page 196 AL-EN

Pressure transmitter PASCAL Ci4

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

WIND CLIPPER KTS ILLUM SCALE INC DEC CLIPPER WIND SYSTEM

REPLACING THE AFT RUDDER CABLES

WL16 WATER LEVEL LOGGERS Submersible pressure transducer and USB datalogger combination

TECHNICAL BULLETIN PINPOINT CONDUIT COUPLING AND SPLICING RECOMMENDATIONS

Diaphragm monitoring system with threaded connection For the chemical and petrochemical industries Model DMS34

Industrial Grade Portable Outlet Boxes, Wire Mesh Grips & Coverplates

SPECIFICATION SHEET. OMEGAFLEX, Ltd. TracPipe Flexible Gas Piping Specification Sheet Specification date. ProjectName

Connecting a SSL/PTV Backflush System

GAS SYSTEM HYDRA GS. The gas installation system that sets new standards. Witzenmann GmbH

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

Hydraulic comparison test pump Models CPP1000-X, CPP1600-X

Spectrum AquaLight (SAL ) Color Underwater Light Owner s Manual

40K TLX Nozzles 40K TLX

Position switches FP series

LMP 307. Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % / 0.

ASSEMBLY INSTRUCTIONS S-Dome system

Transcription:

Industrial cable glands SK-EMC cable glands Cable glands of the SK-series fulfil the highest demands of quality and security. Outstanding high-grade materials are used together with innovative technology to offer premium products. You can find in this chapter: SK EMC cable glands EMC-D version with Best EMI attenuation and easy installation EMC standard version with additional bending protection with additional strain relief We provide variable clamping ranges, thread lengths, thread types plus different sealing materials and temperature ranges. Our range is completed by global certifications. For any further question please do not hesitate to contact us. We look forward to develop solutions together with you. You profit from our vast knowledge in development, engineering and production technology. Contact us: E-Mail: info.et@hummel.com Tel.: +49(0) 76 66/91110-0 Do you need EMC boxes or EMC connectors? You can find suitable solutions in our catalogs Enclosure Solutions and Circular Connectors 29

SK-M-EMV-D Metr., Metr.-elongated M Metalised polyamide Number Number mm mm mm mm mm long M 12 x 1,5 3 6,5 6,5 25 14 1.631.1200.50 10 1.631.1200.30 M 16 x 1,5 4 8 6 29 17/19 1.631.1609.50 10 1.631.1609.30 M 16 x 1,5 5 10 6 32 20 1.631.1600.50 10 1.631.1600.30 M 20 x 1,5 6 12 6 32,5 22 1.631.2013.50 10 1.631.2013.30 M 20 x 1,5 10 14 6 33 24 1.631.2000.50 10 1.631.2000.30 M 25 x 1,5 13 18 7 39 30 1.631.2500.50 12 1.631.2500.30 M 32 x 1,5 18 25 8 45 40 1.631.3200.50 12 1.631.3200.30 M 40 x 1,5 24 32 8 51 50 1.631.4000.50 15 1.631.4000.30 M 50 x 1,5 32 38 9 57,5 57 1.631.5000.50 15 1.631.5000.30 M 63 x 1,5 37 44 10 52 64/68 1.631.6300.50 15 1.631.6300.30 30

SK-M-EMV-D PG Metalised polyamide - Other sealing material e.g. Silicone upon request - Elongated threads on request Number mm mm mm mm PG 7 3 6,5 5 24 14 1.631.0700.01 PG 9 4 8 6 28 17 1.631.0900.01 PG 11 5 10 6 29 20 1.631.1100.01 PG 13,5 6 12 6,5 31 22 1.631.1300.01 PG 16 10 14 6,5 32 24 1.631.1600.01 PG 21 13 18 7 38 30 1.631.2100.01 PG 29 18 25 8 43 40 1.631.2900.01 PG 36 24 32 8 48 50 1.631.3600.01 PG 42 32 38 9 45 57 1.631.4200.01 PG 48 37 44 10 46 64 1.631.4800.01 SK-M-EMV-D NPT Metalised polyamide - Other sealing material e.g. Silicone upon request Number mm mm mm mm 3/8" NPT 4 8 15 29 17/ 19 1.631.3800.70 1/2" NPT 6 12 13 32,5 22/ 24 1.631.1200.70 3/4" NPT 13 18 13 39 30 1.631.3400.70 31

SK-M-EMV Metr., Metr.-elongated EN 50262 Polyamide - Stainless steel on request See our homepage www.hummel.com for assembling advices for maximum cable diameters Number Number mm mm mm mm mm elongated M 12 x 1,5 3 6,5 6,5 19 14 1.691.1200.50 10 1.691.1200.30 M 12 x 1,5 2 5 6,5 19 14 1.691.1200.51 10 1.691.1200.31 M 16 x 1,5 5 10 6 22 20 1.691.1600.50 10 1.691.1600.30 M 16 x 1,5 3 7 6 22 20 1.691.1600.51 10 1.691.1600.31 M 20 x 1,5 10 14 6 24 24 1.691.2000.50 10 1.691.2000.30 M 20 x 1,5 7 12 6 24 24 1.691.2000.51 10 1.691.2000.31 M 25 x 1,5 13 18 7 26 30 1.691.2500.50 12 1.691.2500.30 M 25 x 1,5 9 16 7 26 30 1.691.2500.51 12 1.691.2500.31 M 32 x 1,5 18 25 8 31 40 1.691.3200.50 12 1.691.3200.30 M 32 x 1,5 13 20 8 31 40 1.691.3200.51 12 1.691.3200.31 M 32 x 1,5 15 21 8 33 36 1.691.3200.52 12 1.691.3200.32 M 40 x 1,5 22 32 8 37 50 1.691.4000.50 15 1.691.4000.30 M 40 x 1,5 20 26 8 37 50 1.691.4000.51 15 1.691.4000.31 M 40 x 1,5 19 27 8 33 46 1.691.4000.52 15 1.691.4000.32 M 50 x 1,5 32 38 9 37 57 1.691.5000.50 15 1.691.5000.30 M 50 x 1,5 25 31 9 37 57 1.691.5000.51 15 1.691.5000.31 M 63 x 1,5 37 44 10 38 64 / 68 1.691.6300.50 15 1.691.6300.30 M 63 x 1,5 29 35 10 38 64 / 68 1.691.6300.51 15 1.691.6300.31 32

SK-M-EMV PG, PG-elongated, NPT Polyamide - Also available in PVDF - Stainless steel on request Number Number mm mm mm mm mm elongated PG 7 3 6,5 5 19 14 1.691.0700.01 10 1.691.0700.60 PG 7 2 5 5 19 14 1.691.0700.15 10 1.691.0700.61 PG 9 4 8 6 21 17 1.691.0900.01 10 1.691.0900.60 PG 9 2 6 6 21 17 1.691.0900.15 10 1.691.0900.61 PG 11 5 10 6 22 20 1.691.1100.01 10 1.691.1100.60 PG 11 3 7 6 22 20 1.691.1100.15 10 1.691.1100.61 PG 13,5 6 12 6,5 24 22 1.691.1300.01 10 1.691.1300.60 PG 13,5 5 9 6,5 24 22 1.691.1300.15 10 1.691.1300.61 PG 16 10 14 6,5 23 24 1.691.1600.01 10 1.691.1600.60 PG 16 7 12 6,5 23 24 1.691.1600.15 10 1.691.1600.61 PG 21 13 18 7 24 30 1.691.2100.01 12 1.691.2100.60 PG 21 9 16 7 24 30 1.691.2100.15 12 1.691.2100.61 PG 29 18 25 8 29 40 1.691.2900.01 12 1.691.2900.60 PG 29 13 20 8 29 40 1.691.2900.15 12 1.691.2900.61 PG 36 22 32 8 35 50 1.691.3600.01 15 1.691.3600.60 PG 36 20 26 8 35 50 1.691.3600.15 15 1.691.3600.61 PG 42 32 38 9 37 57 1.691.4200.01 15 1.691.4200.60 PG 42 25 31 9 37 57 1.691.4200.15 15 1.691.4200.61 PG 48 37 44 10 38 64 1.691.4800.01 15 1.691.4800.60 PG 48 29 35 10 38 64 1.691.4800.15 15 1.691.4800.61 3/8 NPT 4 8 15 21 17/ 19 1.691.3800.70 3/8 NPT 2 6 15 21 17/ 19 1.691.3800.71 1/2 NPT 6 12 13 24 22/ 24 1.691.1200.70 1/2 NPT 5 9 13 24 22/ 24 1.691.1200.71 3/4 NPT 13 18 13 25 30 1.691.3400.70 3/4 NPT 9 16 13 25 30 1.691.3400.71 33

SK-M-Flex-EMV Metr., Metr.-elongated EN 50262 Steel spring 1.4310 Polyamide See our homepage www.hummel.com for assembling advices for maximum cable diameters d d Number Number mm mm mm mm mm mm elongated M 12 x 1,5 3 6,5 6,5 55 6,8 14 1.624.1200.50 10 1.624.1200.30 M 12 x 1,5 2 5 6,5 55 6,8 14 1.624.1200.51 10 1.624.1200.31 M 16 x 1,5 5 10 6 77 10,3 20 1.624.1600.50 10 1.624.1600.30 M 16 x 1,5 3 7 6 77 10,3 20 1.624.1600.51 10 1.624.1600.31 M 20 x 1,5 10 14 6 98 14,3 24 1.624.2000.50 10 1.624.2000.30 M 20 x 1,5 7 12 6 98 14,3 24 1.624.2000.51 10 1.624.2000.31 M 25 x 1,5 13 18 7 111 18,4 30 1.624.2500.50 12 1.624.2500.30 M 25 x 1,5 9 16 7 111 18,4 30 1.624.2500.51 12 1.624.2500.31 34

SK-M-Flex-EMV PG, PG-elongated, NPT Steel spring 1.4310 Polyamide - Also available in PVDF d d Number Number mm mm mm mm mm mm elongated PG 7 3 6,5 5 55 6,8 14 1.624.0700.01 10 1.624.0700.60 PG 7 2 5 5 55 6,8 14 1.624.0700.15 10 1.624.0700.61 PG 9 4 8 6 66 8,2 17 1.624.0900.01 10 1.624.0900.60 PG 9 2 6 6 66 8,2 17 1.624.0900.15 10 1.624.0900.61 PG 11 5 10 6 77 10,3 20 1.624.1100.01 10 1.624.1100.60 PG 11 3 7 6 77 10,3 20 1.624.1100.15 10 1.624.1100.61 PG 13,5 6 12 6,5 88 12,3 22 1.624.1300.01 10 1.624.1300.60 PG 13,5 5 9 6,5 88 12,3 22 1.624.1300.15 10 1.624.1300.61 PG 16 10 14 6,5 98 14,3 24 1.624.1600.01 10 1.624.1600.60 PG 16 7 12 6,5 98 14,3 24 1.624.1600.15 10 1.624.1600.61 PG 21 13 18 7 111 18,4 30 1.624.2100.01 12 1.624.2100.60 PG 21 9 16 7 111 18,4 30 1.624.2100.15 12 1.624.2100.61 3/8 NPT 4 8 15 66 8,2 17/ 19 1.624.3800.70 3/8 NPT 2 6 15 66 8,2 17/ 19 1.624.3800.71 1/2 NPT 6 12 13 88 12,3 22/ 24 1.624.1200.70 1/2 NPT 5 9 13 88 12,3 22/ 24 1.624.1200.71 3/4 NPT 13 18 13 111 18,4 30 1.624.3400.70 3/4 NPT 9 16 13 111 18,4 30 1.624.3400.71 35

SK-MZ-EMV Metr., Metr.-elongated, PG, PG-elongated, NPT EN 50262 Polyamide - Also available in PVDF* See our homepage www.hummel.com for assembling advices for maximum cable diameters Number Number mm mm mm mm mm elongated M 12 x 1,5 3 6,5 6,5 26 14 1.692.1200.50 10 1.692.1200.30 M 16 x 1,5 6 10 6 29 20 1.692.1600.50 10 1.692.1600.30 M 20 x 1,5 10 14 6 32 24 1.692.2000.50 10 1.692.2000.30 M 25 x 1,5 13 18 7 35 30 1.692.2500.50 12 1.692.2500.30 M 32 x 1,5 18 25 8 41 40 1.692.3200.50 12 1.692.3200.30 M 40 x 1,5 22 32 8 48 50 1.692.4000.50 15 1.692.4000.30 M 50 x 1,5 32 38 9 51 57 1.692.5000.50 15 1.692.5000.30 M 50 x 1,5 25 31 9 51 57 1.692.5000.51 15 1.692.5000.31 M 63 x 1,5 37 44 10 52 64/68 1.692.6300.50 15 1.692.6300.30 M 63 x 1,5 29 35 10 52 64/68 1.692.6300.51 15 1.692.6300.31 PG 7* 3 6,5 5 26 14 1.692.0700.01 10 1.692.0700.60 PG 9* 4 8 6 28 17 1.692.0900.01 10 1.692.0900.60 PG 11* 6 10 6 29 20 1.692.1100.01 10 1.692.1100.60 PG 13,5* 6 12 6,5 33 22 1.692.1300.01 10 1.692.1300.60 PG 16* 10 14 6,5 32 24 1.692.1600.01 10 1.692.1600.60 PG 21* 13 18 7 35 30 1.692.2100.01 12 1.692.2100.60 PG 29* 18 25 8 41 40 1.692.2900.01 12 1.692.2900.60 PG 36* 22 32 8 48 50 1.692.3600.01 15 1.692.3600.60 PG 42* 32 38 9 51 57 1.692.4200.01 15 1.692.4200.60 PG 42* 25 31 9 51 57 1.692.4200.15 15 1.692.4200.61 PG 48* 37 44 10 51 64 1.692.4800.01 15 1.692.4800.60 PG 48* 29 35 10 51 64 1.692.4800.15 15 1.692.4800.61 3/8 NPT 4 8 15 28 17/ 19 1.692.3800.70 1/2 NPT 6 12 13 29 22/ 24 1.692.1200.70 3/4 NPT 13 18 13 35 30 1.692.3400.70 36

Assembly Instructions SK-M-EMV/ METRICA-M-EMV Step 1 + Strip cable + Expose braided shield Step 2 + Feed cable through dome nut and clamping insert + Fold braided shield over clamping insert + Make sure that braided shield overlaps the by 3/32 (2 mm) Step 3 + Push clamping insert into body and tighten dome nut + Assemble into housing + Finished! 178

Assembly Instructions SK-M-EMV-D Option 1 Feed-through of cable and shield (braided or foil) + Expose shield approximately 7/16 (10mm) + Insert cable into fitting until the shield reaches the contact position + Tighten dome nut Option 2 Feed-through of shield (braided or foil) + Remove cable jacket to expose the shield as required + Insert cable into fitting until the shield reaches the contact position + Tighten dome nut Option 3 Termination of the braided shield in the fitting + Strip cable jacket and braided shield to different lengths + For small diameter cables fold the braided shield back over the cable jacket + Insert cable into fitting until the shield reaches the contact position + Tighten dome nut 179