In-Water Mass Spectrometry for Characterization of Light Hydrocarbon Seeps and Leaks

Similar documents
Applied Technology and Best Practices in CEE. Conference

Underwater cryotrap - membrane inlet system (CT-MIS) for improved in situ analysis of gases by mass spectrometry.

Low-Power Atmospheric Gas Sampling System Based on ART MS Sensor and NEG-Ion Pump

SeaSmart. Jonathan Evans

Marine Opera*ons Group Marine Technology Program SRI Interna*onal SRI International

CALCULATING THE SPEED OF SOUND IN NATURAL GAS USING AGA REPORT NO Walnut Lake Rd th Street Houston TX Garner, IA 50438

Commercial Practice Test Method Internal Vapor Analysis of Hermetic Devices

Discovery TGA 55, TGA 550, TGA Site Preparation Guide

Advanced PMA Capabilities for MCM

Discovery SDT 650. Site Preparation Guide. Revision G Issued December Page 1

Supporting Information for Micro-Collection of. Gases in a Capillary Tube: Preservation of Spatial

Gun Vacuum Performance Measurements February 2003

Autonomous Underwater Vehicles Explorer Class

X-Flow Mass Flow Controller 授权代理 : 北京品超思瑞科技学院公司

NUI Overview. Mike Jakuba Woods Hole Oceanographic Institution

Underwater Robots Jenny Gabel

MASS FLOW SYSTEMS MASS FLOW MEASURING, CONTROLLING AND BLENDING SYSTEMS

Gas Mixture Two Components. Gas Mixtures Two Components

BEST KNOWN METHODS. Transpector XPR3 Gas Analysis System. 1 of 6 DESCRIPTION XPR3 APPLICATIONS PHYSICAL INSTALLATION

Spot the Hazards: Review Confined Space Hazards Missed by Most Safety Professionals, and the PPE Solutions that Meet OSHA Requirements

Discovery HP-TGA 75/750. Site Preparation Guide

The Helium Leak Detector

analytical bulk flow distance FLOW level pressure temperature industrial communication

Agilent 490 Micro GC Natural Gas Analyzer

Field testing of the Nereus network

Performance Overview calibration Laboratory EP Instruments Messtechnik und Kalibrierung GmbH

Misuse of Combustible Gas Meters

Yokosuka Cruise Report YK11-02

Investigating Acoustic Anomalies in the Water Column. Alistair Robertshaw, Geohazards Specialist, BP Oceanology 2016

VIC offers a variety of Calibrated Gas Leaks

Multiple Gas#5 GC configuration Jan 2016

Flare Gas Composition Analysis and QA/QC Lessons Learned and Lessons Lost SPECTRUM ENVIRONMENTAL SOLUTIONS, LLC 1

Potential applications of AUVs and Gliders in Offshore Windfarm Site Surveys

Polar Research Vessel Operational Requirements and Summary of Technical Studies

Total Pressure Measurement Using Residual Gas Analyzers

Technical Manual. Sensepoint XCD Gas Detector

Mitsui Engineering & Shipbuilding Co., LTD. Kenji NAGAHASHI

Digiquartz Water-Balanced Pressure Sensors for AUV, ROV, and other Moving Underwater Applications

ASTM UPDATE to COQA. COQA Meeting Feb San Antonio. RJ (Bob) Falkiner SR (Steve) David GJ (Jay) Grills W (Wayne) Kriel

BACKGROUND TO STUDY CASE

UT 3000 Mercury Ultratracer

Oceanographic Research With The LiquID Station

PHOENIX L300i Best-in-class Helium Leak Detectors

Practical approach and problems in in-situ RGA calibration

the annulus between the second casing string and the surface casing [must be] open to the atmosphere in the manner described in subsection (2).

OMNISTAR / THERMOSTAR. The efficient solution for gas analysis. Intelligent software. Wide range of applications.

Mass Flow Meter (MFM) for Gases

IRwin Methane Leak Detector. Innovation makes the difference

H 2. Sensor Series Take no risk! Install a Hydrogen Sensor in your Gaschromatograph

How well do CMIP5 climate models reproduce Southern Ocean bottom temperature? Model climatology

LINEAR TRANSFORMATION APPLIED TO THE CALIBRATION OF ANALYTES IN VARIOUS MATRICES USING A TOTAL HYDROCARBON (THC) ANALYZER

AND EQUIPMENT FOR ENVIRONMENTAL APPLICATIONS (800) B Polk Street Houston, TX

Cooperative Navigation for Autonomous Underwater Vehicles. Navigare 2011, 4 May 2011, Bern

ALFA Task 2 Deliverable M2.2.1: Underwater Vehicle Station Keeping Results

Department of Physics Standard Operating Procedures (SOP) Approved by: Physics Safety Committee

MAPCO2 Buoy Metadata Report Project Title:

ISO INTERNATIONAL STANDARD

The HumiPyc ( Model 2) - Gas Pycnometer; Density, Moisture, Permeation Analyzer; Filter Integrity Tester; RH sensor Calibrator

Flow and Energy Measurement F-5400 THERMAL MASS FLOW METER

Mass Flow Controller (MFC) for Gases

General Specifications: Forensic. Petrochemical Environmental. Lab Quality Analyses in the Field, It Goes with you Anywhere!

Acoustic Pipeline Inspection Mind The Gap

Keisuke Uchimoto (RITE)

The MEDUSA Deep Sea and FUSION AUVs:

MISSION PLANNING AND DATA ACQUISITION SOFTWARE

Real-time Analysis of Industrial Gases with Online Near- Infrared Spectroscopy

APPLICATION NOTE. Fast Analysis of Coal Mine Gas Using the INFICON 3000 Micro GC ABSTRACT

Vertical in situ profiles of nitrate and oxygen in the northern Japan Sea

Three Columns Gas Chromatograph Analysis Using Correlation between Component's Molecular Weight and Its Response Factor

Customer Responsibilities. Important Customer Information Series Q-TOF LC/MS Systems Site Preparation Checklist

Columbus Instruments

ASTM 3612/TOGA/Dissolved Gas GC Revised October 2013

Nonrefillable Cylinders

Detector Carrier Gas Comments Detector anode purge or reference gas. Electron Capture Nitrogen Maximum sensitivity Nitrogen Argon/Methane

Scanning Sonar and ROV Operations. For Underwater SAR Imaging Applications

NSW Mines Rescue Unmanned Aerial Vehicle (UAV)

General Specifications

Location: Barkley Canyon Date: September 9, 2013 Constraints: none

General Specifications

Direct Gas Sample Introduction System for ICP-MS

Agilent 7800 ICP-MS. Specifications and Typical Performance. Fast track metals analysis with Solution-Ready ICP-MS

S.A. Klein and G.F. Nellis Cambridge University Press, 2011

Model-based Adaptive Acoustic Sensing and Communication in the Deep Ocean with MOOS-IvP

Improving the Measurement Accuracy of Water Partial Pressure Using the Major Constituent Analyzer

Specialty Gases & Equipment ISO 9001: 2008 CERTIFIED. A Division of Norco, Inc.

Technical Data for Alicat M-Series Mass Flow Meters sccm Full Scale through slpm Full Scale

Features. Main Voltage: Vdc. Input Control Signal: 0-5 Vdc or 4-20 madc (Sourcing) Monitor Output Voltage: 0-5 Vdc or 4-20 madc (Sourcing)

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

Power Transformer Maintenance. Maintenance Practices & Procedures for Substation Class Distribution Power Transformers

METHOD 3C - DETERMINATION OF CARBON DIOXIDE, METHANE, NITROGEN, AND OXYGEN FROM STATIONARY SOURCES

DSC 204 HP Phoenix. High-Pressure Differential Scanning Calorimetry up to 15 MPa Method, Technique and Applications

HumiSys HF High Flow RH Generator

M3060 Handling Compressed Gas Cylinders Safely. Leader s Guide

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment Varian 310

Non-floating Oil Spills: Structure and Outcomes

Gases&Technology. Measurement of Impurities in Helium Using the Dielectric Barrier Discharge Helium Ionization Detector. FEATURE.

Tifft Water Supply Symposium

Vieques Underwater Demonstration Project

GasSense NDIR User Manual

Fit for Purpose Compositional Input for Allocation Using Equations of State Thomas Hurstell, Letton Hall Group

Transcription:

In-Water Mass Spectrometry for Characterization of Light Hydrocarbon Seeps and Leaks R. T. Short, S. K. Toler, A. M. Cardenas-Valencia, S. Untiedt, C. Cullins, M. Ryder, and J. Kloske HEMS Workshop 2015 Baltimore, MD 15 September 2015

Outline Need for in-water detection and quantification of hydrocarbons (HCs) Membrane introduction mass spectrometry (MIMS) Underwater MIMS systems Detection of light hydrocarbons Integration of sensor suite with autonomous underwater vehicle (AUV) SRI s underwater MIMS Blueview MBS 1350 multi-beam sonar Turner Design C7 fluorometer Gas and dye plume generator AUV operations in Tampa Bay AUV operations in Santa Barbara Channel Summary

Challenges for the Expanding Oil and Gas Industry Improved exploration and environmental monitoring in the open ocean and coastal regions Cost-effective mapping of HCs over large areas Differentiation of hydrocarbon sources (thermogenic vs. biogenic) Environmental assurance protocols for operations Reliable methods for establishing HC background concentrations (liability) Sensitive leak detection for disaster management

MIMS: Ideal for In Situ Detection of Light HCs and Gases Simultaneously monitor multiple analytes Dissolved gases (oxygen, nitrogen, carbon dioxide), light HCs (methane, ethane, propane, butane), and volatile organic compounds (benzene, toluene, xylene) Full mass scans or selected ion monitoring Up to 45 m/z values with a cycle time of ~5 seconds Introduce analytes from the water column Passive (except for sample pumping and heating, if desired) Frit A porous metal or ceramic frit is used to mechanically support the membrane (hydrostatic pressure)

SRI s MIMS Instrument is AUV Deployable Specifications Power: 60-80 Watts Voltage: 24 VDC Dimensions: Length: 64 cm Diameter: 24 cm Weight: In air: 35 kg In water: 5 kg neg. Depth rating: 2000 m Vacuum Housing with Mass Analyzer Membrane Module Power Distribution Board Roughing Pump Turbo Pump Mass Analyzer Electronics Microcontroller/ Peripheral Board

Typical MIMS Diagnostic Ions M/Z VALUE COMPOUND ISOTOPIC FORM 4 Helium (He) 4 He 15 Methane (CH 4 ) 12 CH 3 Fragment 28 Nitrogen (N 2 ) 14 N 14 N 30 Ethane (C 2 H 6 ) Various 32 Oxygen (O 2 ) 16 O 16 O 34 Oxygen (O 2 ) Hydrogen Sulfide (H 2 S) 16 O 18 O H 2 32 S 39 Propane (C 3 H 8 ) Various 40 Argon (Ar) 40 Ar 44 Carbon Dioxide (CO 2 ) 12 C 16 O 16 O 58 Butane (C 4 H 10 ) Various 78 Benzene (C 6 H 6 ) Various 92 Toluene (C 7 H 8 ) Various 106 Xylene (C 8 H 10 ) Various 128 Naphthalene (C 10 H 8 ) Various

Characterization of an Artificially Generated Seep in Tampa Bay, FL

Artificial Plume Generator Designed and Constructed Device constructed to generate an artificial seep to allow local testing of the AUV sensor suite Helium gas (and at times 2.5% methane in air) released from two small compressed gas cylinders proxy for light HCs Fluorescein dye released from compressible bags proxy for larger oil compounds Deployment time ~1 hour Acoustic release system used for generator recovery

Ion Current (A) Helium Plume Generator Test Used the seawall crane in St. Petersburg to deploy the instruments Lowered the plume generator to seafloor (~10 m depth) Lowered the MIMS Moved the MIMS ~2 m upstream from the plume, then pulled the MIMS through the plume MIMS data for helium (blue) Plume generator MIMS MIMS beside plume MIMS upstream of plume MIMS in plume He plume He plume He plume

Bluefin AUV Equipped with MIMS-based Sensor Suite Custom payload shell designed and constructed for sensor integration into SRI s Bluefin BF-12 AUV MIMS detects light HCs, dissolved gases, and volatile organic compounds Turner Design C7 fluorometer detects fluorescein (can be interchanged with a version to detect oil) Blueview MBS 1350 multi-beam sonar provides bathymetric maps and images of bubble plumes Custom data logger integrates and assimilates multi-sensor data Inertial navigation system provides accurate 3D geo-referencing of multi-sensor data

AUV Operations with Plume Generator Designed the basic survey pattern and programmed it to be downloaded to the AUV Deployed the plume generator near the center of the survey pattern (opened the gas cylinders and started the dye flow) Moved out of the survey pattern and deployed the AUV Downloaded the survey pattern to the AUV, and completed one or two surveys (~30 45 min) Retrieved the AUV and recovered the plume generator (total deployment ~1 hour) Downloaded sensor data from the AUV and devised a new mission plan

Post-processing Software Allows Rapid Data Display Software fuses AUV navigation, MIMS, C7, conductivity, temperature, and Blueview sonar data into georeferenced files/layers viewable in 3D viewer, Fledermaus Specific analytes can be selected from MIMS data and multiple layers of intensities displayed in 3D, along with fluorometer and sonar data Data from multiple dives can be displayed simultaneously Future processing can include calibrated concentration calculations

He (amps) CH 4 (amps) He (amps) Successfully Detected Helium on Multiple Surveys Three days of AUV lawnmower surveys with the plume generator Released helium from both gas cylinders on days 1 & 2 (except the first survey on day 1) Detected helium on most surveys Released helium and 2.5% methane in air on day 3; detected both helium and methane on the last survey Fluorescein was not detected by the C7 fluorometer I Day 1 I Day 2 I Day 3 I

Fledermaus 3D Viewer Display of Multi-sensor Data

He (amps) Embedded Fine-scale Survey Finds Helium Plume Base survey (100-m lines, 50-m spacings) Fine-scale survey (100-m lines, 3-m spacings) Detected helium on three lines of the fine-scale survey (time shift may need to be adjusted) MIMS helium hits Plume Time Fledermaus 3D Plot

Characterization of Natural Hydrocarbon Seeps in Santa Barbara Channel, CA

Natural Hydrocarbon Seeps in Santa Barbara Channel AUV operations with Bluefin Robotics to characterize natural hydrocarbon seeps Test site near Coal Oil Point Shane and Trilogy seeps

Bluefin-12 AUV Equipped with Multi-sensor Payload

AUV Operations in Santa Barbara Channel on R/V Lightning

AUV Deployment and Recovery

Typical AUV Survey Pattern for Seep Characterization Blue box shows the planned survey area for the Trilogy Seep Dotted line indicates the planned large-scale survey Green line shows the actual AUV path with embedded smaller-scale survey Smaller-scale survey was performed for better characterization of detected seep

MIMS Light Hydrocarbon Data from Trilogy Seep MIMS raw data from six AUV surveys (over 5 hours) Similar time-series data profiles for all three analytes One exception at 15:15:50 is still under investigation Methane Ethane Propane

MIMS and Multi-beam Sonar Data for one AUV Line MIMS data correlated with location of seep bubble streams

Summary Bluefin BF-12 AUVs were equipped with a state-of-the-art MIMS-based sensor suite for wide-area surveys of HCs An artificial plume generator was used as a proxy for natural HC seeps or leaks from pipelines or during drilling operations The AUV MIMS-based sensor suite was tested in Tampa Bay, FL to validate operation and survey strategies MIMS detected helium from the plume generator on most surveys Blueview sonar images of the bubble stream were valuable for locating gas plumes and interpreting MIMS data AUV operations in the Santa Barbara Channel demonstrated use of the multi-sensor suite s ability to characterize natural hydrocarbon seeps MIMS hydrocarbon data and multi-beam sonar data are highly correlated A similar approach can be used for early leak detection and characterization from pipelines and rigs

Acknowledgements Mote Marine Lab R/V Eugenie Clark for deployments in Tampa Bay R/V Lightning and crew for deployments in Santa Barbara Channel Funding and operational support from Bluefin Robotics Corporation for deployments in Santa Barbara Channel Thank You! Headquarters: Silicon Valley SRI International 333 Ravenswood Avenue Menlo Park, CA 94025-3493 650.859.2000 St. Petersburg, FL Office SRI International 450 Eighth Avenue SE St. Petersburg, FL 33701 Additional U.S. and international locations www.sri.com timothy.short@sri.com